RESUMEN
BACKGROUND AND AIMS: Prophylactic implantable cardioverter-defibrillators (ICDs) are not recommended until left ventricular ejection fraction (LVEF) has been reassessed 40 to 90â days after an acute myocardial infarction. In the current therapeutic era, the prognosis of sustained ventricular arrhythmias (VAs) occurring during this early post-infarction phase (i.e. within 3â months of hospital discharge) has not yet been specifically evaluated in post-myocardial infarction patients with impaired LVEF. Such was the aim of this retrospective study. METHODS: Data analysis was based on a nationwide registry of 1032 consecutive patients with LVEF ≤ 35% after acute myocardial infarction who were implanted with an ICD after being prescribed a wearable cardioverter-defibrillator (WCD) for a period of 3â months upon discharge from hospital after the index infarction. RESULTS: ICDs were implanted either because a sustained VA occurred while on WCD (VA+/WCD, n = 72) or because LVEF remained ≤35% at the end of the early post-infarction phase (VA-/WCD, n = 960). The median follow-up was 30.9â months. Sustained VAs occurred within 1â year after ICD implantation in 22.2% and 3.5% of VA+/WCD and VA-/WCD patients, respectively (P < .0001). The adjusted multivariable analysis showed that sustained VAs while on WCD independently predicted recurrence of sustained VAs at 1â year (adjusted hazard ratio [HR] 6.91; 95% confidence interval [CI] 3.73-12.81; P < .0001) and at the end of follow-up (adjusted HR 3.86; 95% CI 2.37-6.30; P < .0001) as well as 1-year mortality (adjusted HR 2.86; 95% CI 1.28-6.39; P = .012). CONCLUSIONS: In patients with LVEF ≤ 35%, sustained VA during the early post-infarction phase is predictive of recurrent sustained VAs and 1-year mortality.
RESUMEN
BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.
Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Aleteo Atrial/etiología , Sistema de Registros , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , RecurrenciaRESUMEN
BACKGROUND: Prediction of outcomes remains an unmet need in candidates for LVADs. The development of right-heart failure portends an excess in mortality rates, but imaging parameters of right ventricular systolic function have failed to demonstrate a prognostic role. By integrating pulmonary pressure, right ventriculoarterial coupling could fill this gap. METHODS: The ASSIST-ICD registry was used to test right ventriculoarterial coupling as a surrogate parameter at implantation for the prediction of all-cause mortality. RESULTS: The ratio of the tricuspid annular-plane systolic excursion over the estimated systolic pulmonary pressure (TAPSE/sPAP) was not associated with long-term survival in univariate analysis (Pâ¯=â¯0.89), nor was the pulmonary artery pulsatility index (PAPi) (Pâ¯=â¯0.13). Conversely, the ratio of the right atrial pressure over the pulmonary capillary wedge pressure (RAP/PCWP) was associated with all-cause mortality (P < 0.01). After taking tricuspid regurgitation severity, LVAD indication, LVAD model, age, blood urea nitrogen levels, and pulmonary vascular resistance into account, RAP/PCWP remained associated with survival (HR 1.35 [1.10 - 1.65]; P < 0.01). CONCLUSION: Among pre-implant RVAC surrogates, only RAP/PCWP was associated with long-term all-cause mortality in LVAD recipients. This association was independent of established risk factors.
RESUMEN
AIMS: Superior vena cava (SVC) isolation during atrial fibrillation catheter ablation is limited by the risk of collateral damage to the sinus node and/or the phrenic nerve. Due to its tissue-specificity, we hypothesized the feasibility and safety of pulsed-field ablation (PFA)-based SVC isolation. METHODS AND RESULTS: One hundred and five consecutive patients undergoing PFA-based AF catheter ablation were prospectively included. After pulmonary vein isolation (±posterior wall isolation and electrical cardioversion), SVC isolation was performed using a standardized workflow. Acute SVC isolation was achieved in 105/105 (100%) patients after 6 ± 1 applications. Transient phrenic nerve stunning occurred in 67/105 (64%) patients but without phrenic nerve palsy at the end of the procedure and at hospital discharge. Transient high-degree sinus node dysfunction occurred in 5/105 (4.7%) patients, with no recurrence at the end of the procedure and until discharge. At the 3-month follow-up visit, no complication occurred. CONCLUSION: SVC isolation using a pentaspline PFA catheter is feasible and safe.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Estudios de Factibilidad , Vena Cava Superior , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Masculino , Femenino , Vena Cava Superior/cirugía , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Estudios Prospectivos , Venas Pulmonares/cirugía , Catéteres Cardíacos , Diseño de Equipo , Nervio Frénico/lesionesRESUMEN
BACKGROUND: Learning to interpret electrocardiograms (ECGs) is a crucial objective in medical education. Despite its importance, errors in ECGs interpretation are common, and the optimal teaching methods have not yet been clearly established. OBJECTIVES: To evaluate students' confidence in ECGs analysis and their opinion on current teaching methods, and to assess the effectiveness of a new ECG educational approach. METHODS: First, we conducted a survey on ECG learning among fourth to sixth-year medical students. Second, a 5-week multicenter comparative study was conducted with fourth-year medical students during their cardiology internship. Two different teaching methods were used, assigned by center. The first group participated in 5-minutes workshops 4 times a week using a "reversed classroom" method, supervised by a cardiologist, where students took turns selecting, presenting and discussing ECGs. The control group attended a single 2-hour face-to-face ECG course. All participants completed a 30-minute ECGs analysis test at baseline and after 5 weeks. RESULTS: Out of 401 survey respondents, the confidence levels in ECG interpretation were 3/5 (IQR 2-3) for routine situations and 2/5 (IQR 1-3) for emergency situations. Satisfaction with ECG teaching was low (2/5, IQR 1-3) and 96.3% of respondents favored more extensive ECG training. In the comparative study, 52 students from 3 medical schools were enrolled (control group: n = 27; workshop group: n = 25). Both groups showed significant improvement in exam scores from baseline to 5-week (33/100 ± 12/100 to 44/100 ± 12/100, p < 0.0001 for the control group and 36/100 ± 13/100 to 62/100 ± 12/100, p < 0.0001 for the workshop group). The improvement was significantly greater in the workshop group compared to the control group (+ 26 ± 11 vs. + 11 ± 6, p < 0.001). CONCLUSIONS: Among French medical students who initially reported low confidence and insufficient skills in ECG interpretation, the workshop approach using a "reversed classroom" method was found to be more effective than conventional lecture-based teaching during cardiology internship.
Asunto(s)
Competencia Clínica , Electrocardiografía , Estudiantes de Medicina , Humanos , Competencia Clínica/normas , Educación de Pregrado en Medicina/métodos , Cardiología/educación , Femenino , Masculino , Encuestas y Cuestionarios , Evaluación Educacional , Internado y ResidenciaRESUMEN
BACKGROUND: No study has so far compared Amulet with the new Watchman FLX in terms of residual left atrial appendage (LAA) patency or clinical outcomes in patients undergoing percutaneous LAA closure. METHODS: In the investigator-initiated SWISS APERO trial (Comparison of Amulet Versus Watchman/FLX Device in Patients Undergoing Left Atrial Appendage Closure), patients undergoing LAA closure were randomly assigned (1:1) open label to receive Amulet or Watchman 2.5 or FLX (Watchman) across 8 European centers. The primary end point was the composite of justified crossover to a nonrandomized device during LAA closure procedure or residual LAA patency detected by cardiac computed tomography angiography (CCTA) at 45 days. The secondary end points included procedural complications, device-related thrombus, peridevice leak at transesophageal echocardiography, and clinical outcomes at 45 days. RESULTS: Between June 2018 and May 2021, 221 patients were randomly assigned to Amulet (111 [50.2%]) or Watchman (110 [49.8%]), of whom 25 (22.7%) patients included before October 2019 received Watchman 2.5, and 85 (77.3%) patients received Watchman FLX. The primary end point was assessable in 205 (92.8%) patients and occurred in 71 (67.6%) patients receiving Amulet and 70 (70.0%) patients receiving Watchman, respectively (risk ratio, 0.97 [95% CI, 0.80-1.16]; P=0.713). A single justified crossover occurred in a patient with Amulet who fulfilled LAA patency criteria at 45-day CCTA. Major procedure-related complications occurred more frequently in the Amulet group (9.0% versus 2.7%; P=0.047) because of more frequent bleeding (7.2% versus 1.8%). At 45 days, the peridevice leak rate at transesophageal echocardiography was higher with Watchman than with Amulet (27.5% versus 13.7%, P=0.020), albeit none was major (ie, >5 mm), whereas device-related thrombus was detected in 1 (0.9%) patient with Amulet and 3 (3.0%) patients with Watchman at CCTA and in 2 (2.1%) and 5 (5.5%) patients at transesophageal echocardiography, respectively. Clinical outcomes at 45 days did not differ between the groups. CONCLUSIONS: Amulet was not associated with a lower rate of the composite of crossover or residual LAA patency compared with Watchman at 45-day CCTA. Amulet, however, was associated with lower peridevice leak rates at transesophageal echocardiography, higher procedural complications, and similar clinical outcomes at 45 days compared with Watchman. The clinical relevance of CCTA-detected LAA patency requires further investigation. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03399851.
Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Ecocardiografía Transesofágica/métodos , Humanos , Resultado del TratamientoRESUMEN
AIMS: Left bundle branch area pacing (LBBAP) is a recent technique aiming at preservation of physiological ventricular electrical activation. Our goal was to assess mechanical synchrony parameters in relation to electrocardiographic features during LBBAP performed in routine practice. METHODS AND RESULTS: From June 2020 to August 2021, all patients of our institution with permanent pacemaker implantation indication were eligible for LBBAP. A 'qR' pattern in V1 and a delay from pacing spike to the peak of the R-wave in V6 < 80 ms defined a successful LBBAP. Electrocardiogram and echocardiography were performed during spontaneous rhythm and LBBAP: left ventricular mechanical synchrony (LVMS) parameters using 2D Speckle tracking and interventricular mechanical delay (IVMD) were collected. LBBAP was attempted with success in 134/163 patients (82.2%). During LBBAP, the mean QRS width was 104 ± 12 ms. In patients with left bundle branch block (n = 47), LBBAP provided a significant decrease of QRS width from 139 ± 16 to 105 ± 12 ms (P < 0.001) with reduction of LVMS (53 ± 21 vs. 90 ± 46 ms, P = 0.009), and IVMD (14 ± 13 vs. 49 ± 18 ms, P < 0.001). In patients with right bundle branch block (n = 38), LBBAP led to a significant decrease of QRS width from 134 ± 14 to 106 ± 13 ms (P < 0.001) with no effect on LVMS and a reduction of IVMD (17 ± 14 vs. 50 ± 16 ms, P < 0.001). CONCLUSION: LBBAP in routine practice preserved intra-ventricular mechanical synchrony in patients with narrow and RBBB QRS and improved asynchrony parameters in patients with LBBB.
Asunto(s)
Bloqueo de Rama , Estimulación Cardíaca Artificial , Humanos , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Sistema de Conducción Cardíaco , Electrocardiografía/métodos , Ecocardiografía/métodos , Arritmias Cardíacas , Fascículo AtrioventricularRESUMEN
AIMS: The field of conduction system pacing (CSP) is evolving, and our aim was to obtain a contemporary picture of European CSP practice. METHODS AND RESULTS: A survey was devised by a European CSP Expert Group and sent electronically to cardiologists utilizing CSP. A total of 284 physicians were invited to contribute of which 171 physicians (60.2%; 85% electrophysiologists) responded. Most (77%) had experience with both His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP). Pacing indications ranked highest for CSP were atrioventricular block (irrespective of left ventricular ejection fraction) and when coronary sinus lead implantation failed. For patients with left bundle branch block (LBBB) and heart failure (HF), conventional biventricular pacing remained first-line treatment. For most indications, operators preferred LBBAP over HBP as a first-line approach. When HBP was attempted as an initial approach, reasons reported for transitioning to utilizing LBBAP were: (i) high threshold (reported as >2â V at 1â ms), (ii) failure to reverse bundle branch block, or (iii) > 30â min attempting to implant at His-bundle sites. Backup right ventricular lead use for HBP was low (median 20%) and predominated in pace-and-ablate scenarios. Twelve-lead electrocardiogram assessment was deemed highly important during follow-up. This, coupled with limitations from current capture management algorithms, limits remote monitoring for CSP patients. CONCLUSIONS: This survey provides a snapshot of CSP implementation in Europe. Currently, CSP is predominantly used for bradycardia indications. For HF patients with LBBB, most operators reserve CSP for biventricular implant failures. Left bundle branch area pacing ostensibly has practical advantages over HBP and is therefore preferred by many operators. Practical limitations remain, and large randomized clinical trial data are currently lacking.
Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Volumen Sistólico/fisiología , Función Ventricular Izquierda , Resultado del Tratamiento , Sistema de Conducción Cardíaco , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Arritmias Cardíacas/terapia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapiaRESUMEN
AIMS: Sudden cardiac arrest remains a major complication of acute myocardial infarction (AMI) and is frequently related to ventricular fibrillation (VF). Incidence and impact of VF among patients hospitalized for AMI were evaluated. METHODS AND RESULTS: Data from the FAST-MI programme consisting of 5 French nationwide prospective cohort studies between 1995 and 2015 were analysed, totally including 14 423 patients with AMI (66 ± 14 years, 72% males, 59% ST-elevation myocardial infarction). Overall, proportion of patients presenting in-hospital VF decreased from 3.9% in 1995 to 1.8% in 2015 (P < 0.001). One-year mortality decreased from 60.7% to 24.6% (P < 0.001). However, compared with patients who did not develop VF, the over-risk of 1-year mortality associated with VF was stable over time [hazard ratio (HR) 6.78, 95% confidence interval (CI) 5.03-9.14 in 1995 and HR 6.64, 95% CI 4.20-10.49 in 2015, P = 0.52]. This increased mortality in the VF group was mainly related to fatal events occurring prior to hospital discharge, representing 86.2% of 1-year mortality, despite the very low rate of implantable cardioverter defibrillator in the VF group (2.6%). CONCLUSION: This study demonstrates that in-hospital VF incidence and mortality in the setting of AMI have significantly decreased over the past 20 years. Nevertheless, VF remained steadily associated with approximately a 10-fold increased relative risk of in-hospital mortality, without an impact on post-discharge mortality. Beyond long-term cardiac defibrillation strategy, these results emphasize the need to identify in-hospital interventions to further reduce mortality in VF patients. STUDY REGISTRATION: ClinicalTrials.gov Identifier: NCT00673036, NCT01237418, NCT02566200.
Asunto(s)
Infarto del Miocardio , Fibrilación Ventricular , Masculino , Humanos , Femenino , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia , Estudios Prospectivos , Cuidados Posteriores , Alta del Paciente , Infarto del Miocardio/complicaciones , Infarto del Miocardio/epidemiología , Infarto del Miocardio/terapia , Factores de RiesgoRESUMEN
OBJECTIVES: Temporary circulatory support (TCS) as a bridge-to-left ventricular assist device (BTL) in cardiogenic shock patients has been increasing, but limited data exists on this BTL strategy. We aimed at analyzing the outcome of BTL patients in a population of cardiogenic shock patients compared with those without TCS at the time of the left ventricular assist device (LVAD) surgery and identify predictors of postoperative mortality in this specific population. DESIGN: A multicenter retrospective observational study conducted in 19 centers from 2006 to 2016. SETTING: Nineteen French centers. PATIENTS: A total of 329 cardiogenic shock patients at the time of LVAD implantation were analyzed. Patients were divided in three groups: those under TCS at the time of LVAD implantation (n = 173), those with TCS removal before LVAD surgery (n = 24), and those who did not undergo a bridging strategy (n = 152). Primary endpoint was 30-day mortality. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among the BTL group, 68 (39.3%), 18 (10.4%), and 15 (8.7%) patients were under venoarterial extracorporeal membrane oxygenation, Impella, and IABP support alone, and 72 patients (20.6%) were under multiple TCS support. BTL patients presented similar 30 days survival compared with the TCS removal and non-BTL groups. However, BTL group had a significantly longer ICU duration stay, with two-fold duration of mechanical ventilation time, but the three groups experienced similar postoperative complications. Multivariate analysis identified three independent predictors of mortality in the BTL group: combined surgery with LVAD, body mass index (BMI), and heart failure (HF) duration. BTL strategy was not an independent predictor of mortality in cardiogenic shock patients who underwent LVAD. CONCLUSIONS: BTL strategy is not associated with a lower survival among cardiogenic shock patients with LVAD implantation. Predictors of mortality are combined surgery with LVAD, higher BMI, and HF duration.
Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Corazón Auxiliar , Oxigenación por Membrana Extracorpórea/efectos adversos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Choque Cardiogénico/etiología , Choque Cardiogénico/cirugía , Resultado del TratamientoRESUMEN
AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65â min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Accidente Cerebrovascular , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Persona de Mediana Edad , Venas Pulmonares/cirugía , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Adulto JovenRESUMEN
BACKGROUND: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. METHODS: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event end point was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age, 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (interquartile range) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least 1 appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively; P=0.03). Overall, 71 (43.0%) patients presented with at least 1 ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) patients in primary prevention, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with, respectively, 0, 1, 2, or ≥3 guidelines-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (hazard ratio, 3.47 [95% CI, 1.19-10.11]), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (P=0.006). Patients with congestive heart failure or reduced left ventricular ejection fraction had a higher risk of nonarrhythmic death or heart transplantation (hazard ratio, 11.01 [95% CI, 2.96-40.95]). CONCLUSIONS: Patients with tetralogy of Fallot and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03837574.
Asunto(s)
Desfibriladores Implantables/tendencias , Tetralogía de Fallot/epidemiología , Tetralogía de Fallot/terapia , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Sistema de RegistrosRESUMEN
BACKGROUND: Cryoballoon ablation (CBA) as a first-line rhythm control strategy is superior to antiarrhythmic drugs (AADs) for preventing atrial fibrillation (AF) recurrence; the impact of first-line CBA on quality of life (QoL) and symptoms has not been well characterized. METHODS: Patients aged 18 to 75 with symptomatic paroxysmal AF naïve to rhythm control therapy were randomized (1:1) to CBA (Arctic Front Advance, Medtronic) or AAD (Class I or III). Symptoms and QoL were assessed at baseline, 1, 3, 6, 9, and 12 months using the EHRA classification and Atrial Fibrillation Effect on QualiTy-of-Life (AFEQT) and SF-36v2 questionnaires. Symptomatic palpitations were evaluated via patient diary. RESULTS: Overall, 107 patients were randomized to CBA and 111 to AAD; crossovers occurred in 9%. Larger improvements in the AFEQT summary, subscale and treatment satisfaction scores were observed at 12 months with CBA vs AAD (all P <0.05). At 12 months, the mean adjusted difference in the AFEQT summary score was 9.9 points higher in the CBA group (95% CI: 5.5 -14.2, P <0.001). Clinically important improvements in the SF-36 physical and mental component scores were observed at 12 months in both groups, with no significant between group differences at this timepoint. In the CBA vs AAD group, larger improvements in EHRA class were observed at 6, 9 and 12 months (P <0.05) and the incidence rate of symptomatic palpitations was lower (4.6 vs 15.2 days/year post-blanking; IRR: 0.30, P <0.001). CONCLUSIONS: In patients with symptomatic AF, first-line CBA was superior to AAD for improving AF-specific QoL and symptoms. TRIAL REGISTRATION: ClinicalTrials.gov number: NCT01803438.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Adolescente , Adulto , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Humanos , Persona de Mediana Edad , Calidad de Vida , Resultado del Tratamiento , Adulto JovenRESUMEN
BACKGROUND: Right ventricular pacing (RVP) induces ventricular asynchrony in patients with normal QRS and increases the risk of heart failure and atrial fibrillation in long term. His bundle pacing (HBP) is a physiological alternative to RVP, and could overcome its drawbacks. Recent studies assessed the feasibility and safety of HBP in expert centers with a vast experience of this technique. These results may not apply to less experienced centers. We aim to evaluate the feasibility and safety of permanent HBP performed by physicians who are new to this technique. METHODS: We included all patients who underwent pacemaker implantation with attempt of HBP in three hospitals between September 2017 and January 2020. Indication for HBP was left to operators' discretion. All the operators were new for HBP. His bundle (HB) electrical parameters were recorded at implant, 3- and 12-month follow-up. RESULTS: HBP was successful in 141 of 170 patients (82.9%); selective HBP was obtained in 96 patients and nonselective HBP in 45. The mean procedure and fluoroscopy durations were 67.0 ± 28.8 min, and 7.3 ± 8.1 min (3.1 ± 4.1 Gy·cm2 ), respectively. The mean HB paced QRS duration was 106 ± 18 ms. The mean HB capture threshold was 1.29 ± 0.77 V and did not increase at 3- and 12-month follow-up. The ventricular lead revision was required in five patients. Our results showed a rapid technical learning allowing a high procedure success rate (89.8%) after 15 procedures. CONCLUSION: HBP performed by operators new to this technique appeared feasible and safe. This should encourage HBP to be performed in patients expected to experience high RVP burden.
Asunto(s)
Fibrilación Atrial , Fascículo Atrioventricular , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial , Electrocardiografía , Humanos , Sistema de Registros , Resultado del TratamientoRESUMEN
AIMS: Although cryoenergy safety profile is appropriate for the ablation of arrhythmogenic foci near the conduction system, mapping using the cryoablation catheter is of limited precision. Combining the safety of cryoenergy and the high precision of a 3D mapping system therefore appears the most appropriate set-up for ablation in the vicinity of the His bundle. METHODS AND RESULTS: A 29-year-old woman with a 3-year history of increasing shortness of breath and palpitations refractory to medical treatment was sent to the electrophysiology (EP) laboratory for catheter ablation. Surface electrocardiogram showed sinus rhythm and frequent ectopic beats with narrow QRS complexes similar to those of the sinus beats. The left ventricular ejection fraction was impaired (38%) with no other aetiology found, apart from frequent ectopies. Detailed intracardiac mapping, using a 3D electroanatomical system, revealed that the ectopy originated from the distal His bundle, which was indicated by both antegrade and reversed His bundle activation sequence during ectopy compared to that during sinus rhythm. Due to the proximity of the conduction system, cryoenergy rather than radiofrequency was chosen to target this Hisian ectopy. A special set-up was made in order to allow the cryoablation catheter to be visualized into the 3D mapping system. Cryoenergy delivered to the site of earliest Hisian ectopy activation completely abolished it. CONCLUSION: Such a combined approach may help to improve the therapeutic strategy for ablation procedures with a high risk of injury to the conduction system. It could notably be extended to the ablation of para-Hisian ectopy or accessory pathways.
Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Adulto , Fascículo Atrioventricular/cirugía , Ablación por Catéter/métodos , Electrocardiografía , Femenino , Humanos , Volumen Sistólico , Taquicardia , Función Ventricular IzquierdaRESUMEN
AIMS: Treatment guidelines for patients with atrial fibrillation (AF) suggest that patients should be managed with an antiarrhythmic drug (AAD) before undergoing catheter ablation (CA). This study evaluated whether pulmonary vein isolation employing cryoballoon CA is superior to AAD therapy for the prevention of atrial arrhythmia (AA) recurrence in rhythm control naive patients with paroxysmal AF (PAF). METHODS AND RESULTS: A total of 218 treatment naive patients with symptomatic PAF were randomized (1 : 1) to cryoballoon CA (Arctic Front Advance, Medtronic) or AAD (Class I or III) and followed for 12 months. The primary endpoint was ≥1 episode of recurrent AA (AF, atrial flutter, or atrial tachycardia) >30 s after a prespecified 90-day blanking period. Secondary endpoints included the rate of serious adverse events (SAEs) and recurrence of symptomatic palpitations (evaluated via patient diaries). Freedom from AA was achieved in 82.2% of subjects in the cryoballoon arm and 67.6% of subjects in the AAD arm (HR = 0.48, P = 0.01). There were no group differences in the time-to-first (HR = 0.76, P = 0.28) or overall incidence [incidence rate ratio (IRR)=0.79, P = 0.28] of SAEs. The incidence rate of symptomatic palpitations was lower in the cryoballoon (7.61 days/year) compared with the AAD arm (18.96 days/year; IRR = 0.40, P < 0.001). CONCLUSIONS: Cryoballoon CA was superior to AAD therapy, significantly reducing AA recurrence in treatment naive patients with PAF. Additionally, cryoballoon CA was associated with lower symptom recurrence and a similar rate of SAEs compared with AAD therapy.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Antiarrítmicos/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del TratamientoRESUMEN
BACKGROUND: Frequency and distribution of left ventricular (LV) venous collaterals were studied in vivo to evaluate the ease and feasibility of implanting a new ultra-thin LV quadripolar microlead for cardiac resynchronization therapy (CRT).MethodsâandâResults:Evaluable venograms were analyzed to define the prevalence of venous collaterals (>0.5 mm diameter) between: (1) different LV segments; and (2) different major LV veins in: unselected patients who underwent CRT from 2008 to 2012 at Rouen Hospital, France (retrospective); and CRT patients from the Axone Acute pilot study in 2018 (prospective). In prospective patients with evaluable venograms, LV microlead implantation was attempted. Thirty-six (21/65 retrospective, 15/20 prospective) patients had evaluable venograms with ≥1 visible venous collaterals. Collaterals were found between LV veins in all CRT patients with evaluable venograms. Regionally, prevalence was highest between: the apical inferior and apical lateral (42%); and mid inferior and mid inferolateral (42%) segments. Collateral connections were most prevalent between: the inferior interventricular vein (IIV) and lateral vein (64% [23/36]); and IIV and infero-lateral vein (36% [13/36]). Cross-vein microlead implantation was possible in 18 patients (90%), and single-vein implantation was conducted in the other 2 patients (10%). CONCLUSIONS: Venous collaterals were found in vivo between LV veins in all CRT patients with evaluable venograms, making this network an option for accessing multiple LV sites using a single LV microlead.
Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Dispositivos de Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapia , Humanos , Proyectos Piloto , Estudios Prospectivos , Estudios Retrospectivos , Resultado del TratamientoAsunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Cierre del Apéndice Auricular Izquierdo , Warfarina , Anticoagulantes , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Cateterismo Cardíaco/efectos adversosRESUMEN
BACKGROUND: An accurate estimation of the risk of life-threatening (LT) ventricular tachyarrhythmia (VTA) in patients with LMNA mutations is crucial to select candidates for implantable cardioverter-defibrillator implantation. METHODS: We included 839 adult patients with LMNA mutations, including 660 from a French nationwide registry in the development sample, and 179 from other countries, referred to 5 tertiary centers for cardiomyopathies, in the validation sample. LTVTA was defined as (1) sudden cardiac death or (2) implantable cardioverter defibrillator-treated or hemodynamically unstable VTA. The prognostic model was derived using the Fine-Gray regression model. The net reclassification was compared with current clinical practice guidelines. The results are presented as means (SD) or medians [interquartile range]. RESULTS: We included 444 patients, 40.6 (14.1) years of age, in the derivation sample and 145 patients, 38.2 (15.0) years, in the validation sample, of whom 86 (19.3%) and 34 (23.4%) experienced LTVTA over 3.6 [1.0-7.2] and 5.1 [2.0-9.3] years of follow-up, respectively. Predictors of LTVTA in the derivation sample were: male sex, nonmissense LMNA mutation, first degree and higher atrioventricular block, nonsustained ventricular tachycardia, and left ventricular ejection fraction (https://lmna-risk-vta.fr). In the derivation sample, C-index (95% CI) of the model was 0.776 (0.711-0.842), and the calibration slope 0.827. In the external validation sample, the C-index was 0.800 (0.642-0.959), and the calibration slope was 1.082 (95% CI, 0.643-1.522). A 5-year estimated risk threshold ≥7% predicted 96.2% of LTVTA and net reclassified 28.8% of patients with LTVTA in comparison with the guidelines-based approach. CONCLUSIONS: In comparison with the current standard of care, this risk prediction model for LTVTA in laminopathies significantly facilitated the choice of candidates for implantable cardioverter defibrillators. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03058185.
Asunto(s)
Cardiomiopatías/complicaciones , Desfibriladores Implantables/efectos adversos , Taquicardia Ventricular/etiología , Adulto , Femenino , Humanos , Masculino , Taquicardia Ventricular/patología , Estudios de Validación como AsuntoRESUMEN
BACKGROUND: The coronary sinus (CS) is surrounded by a myocardial coat with extensive connections to the left and right atria that contributes to the interatrial electrical connection. Whereas epicardial connections between CS musculature and the left atrium have largely been demonstrated, clinically relevant epicardial connections from the CS musculature toward the low right atrium (LRA) and epicardial connections between two regions of the right atrium remain questionable. METHODS: Five patients underwent electrophysiology (EP) study for typical atrial flutter (AFl) using either conventional multipolar catheters (four patients) or three-dimensional high-density mapping system (one patient). RESULTS: All five patients had a similar sequence of events during the EP studies. After several cavotricuspid isthmus (CTI) radiofrequency (RF) applications, double potentials were recorded along the ablation line while tachycardia persisted. The right atrial activation pattern strongly suggested the presence of a complete endocardial CTI line of the block. Based on the detailed conventional atrial mapping, RF applications at the middle cardiac vein/CS ostium allowed sinus rhythm restoration in four patients. High-density mapping showed an early breakthrough site at the septal side of the ablation line, close to the CS ostium during counterclockwise AFl, in the fifth patient. RF applications at this site resulted in tachycardia termination. CONCLUSION: Our observations suggested the existence of epicardial fibers connecting the LRA with either the CS musculature or a remote right atrial region. When AFl ablation fails whereas evidence for the local endocardial block is observed, the operators should integrate this finding in the diagnosis and ablation strategy.