Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Phys Chem Chem Phys ; 25(33): 21868-21874, 2023 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-37448300

RESUMEN

Our previous study showed that a rhodium (Rh) cocatalyst is indispensable for ring hydrogenation of benzoic acid over a titanium(IV) oxide (TiO2) photocatalyst. In this study, we explored ring hydrogenation under an Rh-free condition by using two kinds of cocatalyst that were inactive for this reaction when used solely. Cyclohexanecarboxylic acid as the ring hydrogenation product was successfully obtained when ruthenium (Ru) and palladium (Pd) were simultaneously loaded on TiO2, indicating that this bimetallic system can be used in place of an Rh cocatalyst in ring hydrogenation. The state and distribution of Ru and Pd in particles loaded on TiO2 were investigated by transmission electron microscopy, X-ray photon spectroscopy, and X-ray absorption near edge structure analysis. The functions of Ru and Pd as cocatalysts are discussed on the basis of results of characterization and activity tests. The effects of different contents of Ru and Pd in Ru-Pd/TiO2 prepared by a two-step photodeposition method on catalytic activity and the features of the reaction system were investigated in detail.

2.
Opt Express ; 30(24): 43888-43899, 2022 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-36523077

RESUMEN

Optical enhancement cavities enabling laser pulses to be coherently stacked in free space are used in several applications to enhance accessible optical power. In this study, we develop an optical cavity that accumulates harmonically mode-locked laser pulses with a self-resonating mechanism for X-ray sources based on laser-Compton scattering. In particular, a Fabry-Perot cavity composed of 99% reflectance mirrors maintained the optical resonance in a feedback-free fashion for more than half an hour and automatically resumed the accumulation even if the laser oscillation was suspended. In contrast to conventional optical enhancement cavity systems with a dedicated feedback controller, this characteristic is highly beneficial in practical applications, such as for laser-Compton scattering X-ray sources. Lastly, upscaling and adoption of the proposed system might improve the operability and equipment use of laser Compton-scattering X-ray sources.

3.
Rev Sci Instrum ; 89(2): 023305, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29495841

RESUMEN

We describe the stabilization technique of an optical enhancement cavity using a counter propagating mode. The burst amplification of the injection laser in the main path induces a drastic change in the laser intensity and disturbs the stabilization of the enhancement cavity. We have used a counter propagating mode to achieve a 4% intensity jitter and 0.6 mJ pulse storage inside the cavity at the maximum of the burst region. Our results indicate that the counter propagating mode has the same resonant condition as the main mode and thus becomes useful for stabilizing the enhancement cavity. We also determined that the burst amplification brought about no decrease in the enhancement factor in the cavity due to the degradation of laser quality.

5.
Rev Sci Instrum ; 80(12): 123304, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20059137

RESUMEN

X-ray generation based on laser-electron Compton scattering is one attractive method to achieve a compact laboratory-sized high-brightness x-ray source. We have designed, built, and tested such a source; it combines a 50 MeV multibunch electron linac with a mode-locked 1064 nm laser stored and amplified in a Fabry-Perot optical cavity. We directly observed trains of pulsed x rays using a microchannel plate detector; the resultant yield was found to be 1.2x10(5) Hz in good agreement with prediction. We believe that the result has demonstrated good feasibility of linac-based compact x-ray sources via laser-electron Compton scatterings.

6.
Phys Rev Lett ; 93(24): 244802, 2004 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-15697821

RESUMEN

An experiment on the investigation of optical diffraction radiation (ODR) from a slit target as a possible tool for noninvasive electron beam-size diagnostics has been performed at the KEK accelerator test facility. The experimental setup has been installed at the diagnostics section of the extraction line. We have performed the first incoherent ODR observation from a slit target. The measured angular distributions are in reasonable agreement with the theoretical expectation. The beam-size effect onto the ODR angular pattern has been observed. Moreover, the sensitivity to the beam size as small as 14 microm has been achieved.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA