Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
NMR Biomed ; 28(10): 1228-35, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26269329

RESUMEN

The aim of this study was to implement and evaluate a flexible and time-efficient interleaved imaging approach for the acquisition of proton and sodium images of the human knee at 7 T within a clinically relevant timescale. A flexible software framework was established which allowed the interleaving of multiple, different, fully specific absorption ratio (SAR)-validated scans. The system was able to switch between these different scans at flexible time points. The practical example presented consists of interleaved proton (Dixon imaging and T2* mapping) and sodium (mapping the sodium content and fluid-suppressed component separately) sequences with the key idea to perform proton MRI whilst the sodium nuclei relax towards thermal equilibrium, and vice versa. Comparisons were made between these four scans being acquired sequentially in the normal mode of scanner operation and those acquired in an interleaved fashion. Images acquired in the interleaved mode were very similar to those acquired in sequential scans with no image artifacts produced by the slight intra-sequence variation in steady-state magnetization. A reduction in scanning time of almost a factor of two was established using the interleaved scans, allowing such a protocol to be completed within 30 min. Phantom experiments and in vivo scans performed in healthy volunteers and in one patient proved the basic feasibility of this approach. This approach for the interleaving of multiple proton and sodium scans, each with different contrasts, is an efficient method for the design of new practical clinical protocols for sodium MRI.


Asunto(s)
Aumento de la Imagen/métodos , Rodilla/anatomía & histología , Espectroscopía de Protones por Resonancia Magnética/métodos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Osteoartritis/metabolismo , Osteoartritis/patología , Fantasmas de Imagen , Espectroscopía de Protones por Resonancia Magnética/instrumentación , Protones , Isótopos de Sodio , Programas Informáticos , Factores de Tiempo
2.
Magn Reson Med ; 68(4): 1325-31, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22887743

RESUMEN

An annular dielectric resonator made from distilled water has been designed to operate in degenerate quadrature HEM11 modes at 298.1 MHz (7 Tesla). The circularly polarized B1+ field has a high degree of homogeneity throughout a sample placed within the annulus. The sensitivity of the resonator was measured to be essentially identical to that of an eight-rung high-pass birdcage resonator with the same physical dimensions. High resolution in vivo images have been obtained from the human wrist. A new method of electronically detuning the resonator has also been evaluated. The design is extremely simple and rapid to build, with direct applicability to very high field imaging and also potential integration into human and animal hybrid position emission tomography (PET)/MRI and single-photon emission computed tomography (SPECT)/MRI systems due to the lack of conductor attenuation-induced artifacts in the reconstructed nuclear medicine images.


Asunto(s)
Aumento de la Imagen/instrumentación , Imagen por Resonancia Magnética/instrumentación , Magnetismo/instrumentación , Transductores , Agua , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA