Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur J Neurosci ; 59(8): 2075-2086, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38409515

RESUMEN

Working memory (WM) is one of the fundamental cognitive functions associated with the dorsolateral prefrontal cortex (DLPFC). However, the neurochemical mechanisms of WM, including the dynamic changes in neurometabolites such as glutamate and GABA in the DLPFC, remain unclear. Here, we investigated WM-related glutamate and GABA changes, alongside hemodynamic responses in the DLPFC, using a combination of functional magnetic resonance spectroscopy (fMRS) and functional magnetic resonance imaging (fMRI). During a WM task, we measured Glx (glutamate + glutamine) and GABA levels using GABA editing MEscher-GArwood Point REsolved Spectroscopy (MEGA-PRESS) sequence and blood-oxygen-level-dependent (BOLD) signal changes. In the DLPFC, we observed elevated Glx levels and increased BOLD signal changes during a 2-back task. Specifically, the Glx levels in the DLPFC were significantly higher during the 2-back task compared with fixation, although this difference was not significant when compared with a 0-back task. However, Glx levels during the 0-back task were higher than during fixation. Furthermore, there was a positive correlation between Glx levels in the DLPFC during the 2-back task and the corresponding BOLD signal changes. Notably, higher Glx increases were associated with increased DLPFC activation and lower WM task performance in individuals. No notable changes in DLPFC GABA levels were observed during WM processing. These findings suggest that the modulation of glutamatergic activity in the DLPFC may play a crucial role in both working memory processing and its associated performance outcomes.


Asunto(s)
Corteza Prefontal Dorsolateral , Memoria a Corto Plazo , Humanos , Memoria a Corto Plazo/fisiología , Corteza Prefrontal/diagnóstico por imagen , Corteza Prefrontal/fisiología , Ácido Glutámico , Imagen por Resonancia Magnética , Ácido gamma-Aminobutírico
2.
J Magn Reson Imaging ; 49(1): 195-203, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-29697883

RESUMEN

BACKGROUND: Metabolite concentrations are fundamental biomarkers of disease and prognosis. Magnetic resonance spectroscopy (MRS) is a noninvasive method for measuring metabolite concentrations; however, quantitation is affected by T2 relaxation. PURPOSE: To estimate T2 relaxation times in pediatric brain tumors and assess how variation in T2 relaxation affects metabolite quantification. STUDY TYPE: Retrospective. POPULATION: Twenty-seven pediatric brain tumor patients (n = 17 pilocytic astrocytoma and n = 10 medulloblastoma) and 24 age-matched normal controls. FIELD STRENGTH/SEQUENCE: Short- (30 msec) and long-echo (135 msec) single-voxel MRS acquired at 1.5T. ASSESSMENT: T2 relaxation times were estimated by fitting signal amplitudes at two echo times to a monoexponential decay function and were used to correct metabolite concentration estimates for relaxation effects. STATISTICAL TESTS: One-way analysis of variance (ANOVA) on ranks were used to analyze the mean T2 relaxation times and metabolite concentrations for each tissue group and paired Mann-Whitney U-tests were performed. RESULTS: The mean T2 relaxation of water was measured as 181 msec, 123 msec, 90 msec, and 86 msec in pilocytic astrocytomas, medulloblastomas, basal ganglia, and white matter, respectively. The T2 of water was significantly longer in both tumor groups than normal brain (P < 0.001) and in pilocytic astrocytomas compared with medulloblastomas (P < 0.01). The choline T2 relaxation time was significantly longer in medulloblastomas compared with pilocytic astrocytomas (P < 0.05), while the T2 relaxation time of NAA was significantly shorter in pilocytic astrocytomas compared with normal brain (P < 0.001). Overall, the metabolite concentrations were underestimated by ∼22% when default T2 values were used compared with case-specific T2 values at short echo time. The difference was reduced to 4% when individually measured water T2 s were used. DATA CONCLUSION: Differences exist in water and metabolite T2 relaxation times for pediatric brain tumors, which lead to significant underestimation of metabolite concentrations when using default water T2 relaxation times. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:195-203.


Asunto(s)
Astrocitoma/diagnóstico por imagen , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/metabolismo , Encéfalo/diagnóstico por imagen , Espectroscopía de Resonancia Magnética , Meduloblastoma/diagnóstico por imagen , Ácido Aspártico/metabolismo , Niño , Colina/metabolismo , Creatina/metabolismo , Femenino , Humanos , Masculino , Control de Calidad , Valores de Referencia , Reproducibilidad de los Resultados , Estudios Retrospectivos
3.
MAGMA ; 32(2): 247-258, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30460431

RESUMEN

OBJECTIVE: To develop and assess a short-duration JPRESS protocol for detection of overlapping metabolite biomarkers and its application to paediatric brain tumours at 3 Tesla. MATERIALS AND METHODS: The short-duration protocol (6 min) was optimised and compared for spectral quality to a high-resolution (38 min) JPRESS protocol in a phantom and five healthy volunteers. The 6-min JPRESS was acquired from four paediatric brain tumours and compared with short-TE PRESS. RESULTS: Metabolite identification between the 6- and 38-min protocols was comparable in phantom and volunteer data. For metabolites with Cramer-Rao lower bounds > 50%, interpretation of JPRESS increased confidence in assignment of lactate, myo-Inositol and scyllo-Inositol. JPRESS also showed promise for the detection of glycine and taurine in paediatric brain tumours when compared to short-TE MRS. CONCLUSION: A 6-min JPRESS protocol is well tolerated in paediatric brain tumour patients. Visual inspection of a 6-min JPRESS spectrum enables identification of a range of metabolite biomarkers of clinical interest.


Asunto(s)
Biomarcadores de Tumor/metabolismo , Neoplasias Encefálicas/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Adulto , Encéfalo/metabolismo , Niño , Femenino , Glicina/metabolismo , Voluntarios Sanos , Humanos , Inositol/metabolismo , Ácido Láctico/metabolismo , Espectroscopía de Resonancia Magnética/estadística & datos numéricos , Masculino , Fantasmas de Imagen , Taurina/metabolismo , Adulto Joven
4.
NMR Biomed ; 28(7): 792-800, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25943246

RESUMEN

MRS thermometry has been utilized to measure temperature changes in the brain, which may aid in the diagnosis of brain trauma and tumours. However, the temperature calibration of the technique has been shown to be sensitive to non-temperature-based factors, which may provide unique information on the tissue microenvironment if the mechanisms can be further understood. The focus of this study was to investigate the effects of varied protein content on the calibration of MRS thermometry at 3 T, which has not been thoroughly explored in the literature. The effects of ionic concentration and magnetic field strength were also considered. Temperature reference materials were controlled by water circulation and freezing organic fixed-point compounds (diphenyl ether and ethylene carbonate) stable to within 0.2 °C. The temperature was measured throughout the scan time with a fluoro-optic probe, with an uncertainty of 0.16 °C. The probe was calibrated at the National Physical Laboratory (NPL) with traceability to the International Temperature Scale 1990 (ITS-90). MRS thermometry measures were based on single-voxel spectroscopy chemical shift differences between water and N-acetylaspartate (NAA), Δ(H20-NAA), using a Philips Achieva 3 T scanner. Six different phantom solutions with varying protein or ionic concentration, simulating potential tissue differences, were investigated within a temperature range of 21-42 °C. Results were compared with a similar study performed at 1.5 T to observe the effect of field strengths. Temperature calibration curves were plotted to convert Δ(H20-NAA) to apparent temperature. The apparent temperature changed by -0.2 °C/% of bovine serum albumin (BSA) and a trend of 0.5 °C/50 mM ionic concentration was observed. Differences in the calibration coefficients for the 10% BSA solution were seen in this study at 3 T compared with a study at 1.5 T. MRS thermometry may be utilized to measure temperature and the tissue microenvironment, which could provide unique unexplored information for brain abnormalities and other pathologies.


Asunto(s)
Algoritmos , Química Encefálica , Espectroscopía de Resonancia Magnética/métodos , Proteínas/química , Termografía/métodos , Animales , Calibración , Humanos , Concentración de Iones de Hidrógeno , Iones , Campos Magnéticos , Espectroscopía de Resonancia Magnética/normas , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Termografía/normas
5.
NMR Biomed ; 27(10): 1222-9, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25125325

RESUMEN

(1)H MRS thermometry has been investigated for brain trauma and hypothermia monitoring applications but has not been explored in brain tumours. The proton resonance frequency (PRF) of water is dependent on temperature but is also influenced by microenvironment factors, such as fast proton exchange with macromolecules, ionic concentration and magnetic susceptibility. (1)H MRS has been utilized for brain tumour diagnostic and prognostic purposes in children; however, the water PRF measure may provide complementary information to further improve characterization. Water PRF values were investigated from a repository of MRS data acquired from childhood brain tumours and children with apparently normal brains. The cohort consisted of histologically proven glioma (22), medulloblastoma (19) and control groups (28, MRS in both the basal ganglia and parietal white matter regions). All data were acquired at 1.5 T using a short TE (30 ms) single voxel spectroscopy (PRESS) protocol. Water PRF values were calculated using methyl creatine and total choline. Spectral peak amplitude weighted averaging was used to improve the accuracy of the measurements. Mean PRF values were significantly larger for medulloblastoma compared with glioma, with a difference in the means of 0.0147 ppm (p < 0.05), while the mean PRF for glioma was significantly lower than for the healthy cohort, with a difference in the means of 0.0061 ppm (p < 0.05). This would suggest the apparent temperature of the glioma group was ~1.5 °C higher than the medulloblastomas and ~0.7 °C higher than a healthy brain. However, the PRF shift may not reflect a change in temperature, given that alterations in protein content, microstructure and ionic concentration contribute to PRF shifts. Measurement of these effects could also be used as a supplementary biomarker, and further investigation is required. This study has shown that the water PRF value has the potential to be used for characterizing childhood brain tumours, which has not been reported previously.


Asunto(s)
Agua Corporal/química , Neoplasias Encefálicas/química , Glioma/química , Meduloblastoma/química , Neuroimagen/métodos , Espectroscopía de Protones por Resonancia Magnética , Temperatura , Termometría/métodos , Microambiente Tumoral , Adolescente , Algoritmos , Biomarcadores de Tumor , Neoplasias Cerebelosas/química , Niño , Preescolar , Colina/análisis , Creatina/análisis , Femenino , Humanos , Lactante , Masculino , Estudios Prospectivos , Protones , Estudios Retrospectivos , Sustancia Blanca/química
6.
JMIR Res Protoc ; 11(1): e31925, 2022 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-35049517

RESUMEN

BACKGROUND: Depression is a substantial health and economic burden. In approximately one-third of patients, depression is resistant to first-line treatment; therefore, it is essential to find alternative treatments. Transcranial magnetic stimulation (TMS) is a neuromodulatory treatment involving the application of magnetic pulses to the brain that is approved in the United Kingdom and the United States in treatment-resistant depression. This trial aims to compare the clinical effectiveness, cost-effectiveness, and mechanism of action of standard treatment repetitive TMS (rTMS) targeted at the F3 electroencephalogram site with a newer treatment-a type of TMS called theta burst stimulation (TBS) targeted based on measures of functional brain connectivity. This protocol outlines brain imaging acquisition and analysis for the Brain Imaging Guided Transcranial Magnetic Stimulation in Depression (BRIGhTMIND) study trial that is used to create personalized TMS targets and answer the proposed mechanistic hypotheses. OBJECTIVE: The aims of the imaging arm of the BRIGhTMIND study are to identify functional and neurochemical brain signatures indexing the treatment mechanisms of rTMS and connectivity-guided intermittent theta burst TMS and to identify imaging-based markers predicting response to treatment. METHODS: The study is a randomized double-blind controlled trial with 1:1 allocation to either 20 sessions of TBS or standard rTMS. Multimodal magnetic resonance imaging (MRI) is acquired for each participant at baseline (before TMS treatment) with T1-weighted and task-free functional MRI during rest used to estimate TMS targets. For participants enrolled in the mechanistic substudy, additional diffusion-weighted sequences are acquired at baseline and at posttreatment follow-up 16 weeks after treatment randomization. Core data sets of T1-weighted and task-free functional MRI during rest are acquired for all participants and are used to estimate TMS targets. Additional sequences of arterial spin labeling, magnetic resonance spectroscopy, and diffusion-weighted images are acquired depending on the recruitment site for mechanistic evaluation. Standard rTMS treatment is targeted at the F3 electrode site over the left dorsolateral prefrontal cortex, whereas TBS treatment is guided using the coordinate of peak effective connectivity from the right anterior insula to the left dorsolateral prefrontal cortex. Both treatment targets benefit from the level of MRI guidance, but only TBS is provided with precision targeting based on functional brain connectivity. RESULTS: Recruitment began in January 2019 and is ongoing. Data collection is expected to continue until January 2023. CONCLUSIONS: This trial will determine the impact of precision MRI guidance on rTMS treatment and assess the neural mechanisms underlying this treatment in treatment-resistant depressed patients. TRIAL REGISTRATION: ISRCTN Registry ISRCTN19674644; https://www.isrctn.com/ISRCTN19674644. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/31925.

7.
Sleep Med ; 62: 53-58, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31557687

RESUMEN

OBJECTIVE: To explore the small-world properties of brain functional networks in patients with obstructive sleep apnea-hypopnea syndrome (OSAHS) to aid diagnosis. METHODS: A total of 29 OSAHS patients and 26 matched healthy volunteers were scanned with blood oxygen level-dependent functional magnetic resonance imaging (BOLD-fMRI) separately, and the whole brain was divided into 90 districts via automated anatomical labeling. The matrix Z was then built through a Fisher Z transformation. Two-sample t tests were applied to evaluate the changes in small-world properties in OSAHS patients compared to the control group. The properties included Eglobal, Elocal, and small-world parameters Lp, Cp, γ, λ, and σ. RESULTS: Both groups satisfied the small-world properties (σ > 1) within the sparsity range of 0.1-0.2. However, compared with the control group, the OSAHS group performed significantly lower in Cp, Elocal, and Eglobal (p < 0.05) and higher in Lp (p < 0.05). The γ, σ, and λ values were not significantly different between the two groups. CONCLUSION: Both healthy and OSAHS patients exhibited small-world properties in functional networks, but a subset of these small-world properties in OSAHS patients performed differently. These changes will not only provide a new perspective for pathophysiological mechanisms of OSAHS but will also help in understanding the disease in terms of whole-brain functional networks.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/fisiopatología , Oxígeno/sangre , Apnea Obstructiva del Sueño/fisiopatología , Adulto , Algoritmos , Índice de Masa Corporal , Encéfalo/metabolismo , Estudios de Casos y Controles , Grupos Control , Femenino , Neuroimagen Funcional/instrumentación , Humanos , Incidencia , Imagen por Resonancia Magnética/métodos , Masculino , Pruebas de Estado Mental y Demencia/normas , Persona de Mediana Edad , Redes Neurales de la Computación , Polisomnografía/métodos , Apnea Obstructiva del Sueño/epidemiología
8.
Neurooncol Pract ; 6(6): 428-437, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31832213

RESUMEN

BACKGROUND: 1H-magnetic resonance spectroscopy (MRS) facilitates noninvasive diagnosis of pediatric brain tumors by providing metabolite profiles. Prospective studies of diagnostic accuracy and comparisons with conventional MRI are lacking. We aimed to evaluate diagnostic accuracy of MRS for childhood brain tumors and determine added clinical value compared with conventional MRI. METHODS: Children presenting to a tertiary pediatric center with brain lesions from December 2015 through 2017 were included. MRI and single-voxel MRS were acquired on 52 tumors and sequentially interpreted by 3 radiologists, blinded to histopathology. Proportions of correct diagnoses and interrater agreement at each stage were compared. Cases were reviewed to determine added value of qualitative radiological review of MRS through increased certainty of correct diagnosis, reduced number of differentials, or diagnosis following spectroscopist evaluation. Final diagnosis was agreed by the tumor board at study end. RESULTS: Radiologists' principal MRI diagnosis was correct in 69%, increasing to 77% with MRS. MRI + MRS resulted in significantly more additional correct diagnoses than MRI alone (P = .035). There was a significant increase in interrater agreement when correct with MRS (P = .046). Added value following radiologist interpretation of MRS occurred in 73% of cases, increasing to 83% with additional spectroscopist review. First histopathological diagnosis was available a median of 9.5 days following imaging, with 25% of all patients managed without conclusive histopathology. CONCLUSIONS: MRS can improve the accuracy of noninvasive diagnosis of pediatric brain tumors and add value in the diagnostic pathway. Incorporation into practice has the potential to facilitate early diagnosis, guide treatment planning, and improve patient care.

9.
Oncotarget ; 9(27): 18858-18868, 2018 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-29721167

RESUMEN

Paediatric brain tumours have a high mortality rate and are the most common solid tumour of childhood. Identification of high risk patients may allow for better treatment stratification. Magnetic Resonance Spectroscopy (MRS) provides a non-invasive measure of brain tumour metabolism and quantifies metabolite survival markers to aid in the clinical management of patients. Glycine can be identified using MRS and has been recently found to be important for cancer cell proliferation in tumours making it a valuable prognostic marker. The aims of this study were to investigate glycine and its added value to MRS as a prognostic marker for paediatric brain tumours in a clinical setting. 116 children with newly diagnosed brain tumours were examined with short echo-time MRS at the Birmingham Children's Hospital and followed up for five years. Survival analysis was performed using Cox regression on the entire metabolite basis set with focus on glycine and three other established survival markers for comparison: n-acetylaspartate, scyllo-inositol and lipids at 1.3 ppm. Multivariate Cox regression was used in conjunction with risk values to establish if glycine added prognostic power when combined to the established survival markers. Glycine was found to be a marker of poor prognosis in the cohort (p < 0.05) and correlated with tumour grade (p < 0.01). The addition of glycine improved the prognostic power of MRS compared to using the combination of established survival markers alone. Tumour glycine was found to improve the MRS prediction of reduced survival in paediatric brain tumours aiding the non-invasive assessment of these children.

10.
Magn Reson Imaging ; 30(2): 189-94, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22055748

RESUMEN

Prostate cancer detection using diffusion-weighted imaging is highly affected by the accuracy of the apparent diffusion coefficient (ADC) values in an image. Echo planar imaging (EPI) is a fast sequence commonly used for diffusion imaging but has inherent magnetic susceptibility and chemical shift artefacts associated. A diffusion sequence that is less affected by these artefacts is therefore advantageous. The half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence was chosen. The diffusion sequences were compared in image quality, repeatability of the ADC value and the effect on the ADC value with varied b values. Eight volunteers underwent three scans of each sequence, on a 1.5-T Siemens system, using b values of 0, 150, 300, 450, 600, 750, 900 and 1000 s/mm(2). ADC maps were created to address the reproducibility of the ADC value when using two b values compared to eight b values. The ADC value using all b values with the HASTE sequence gave the best performance in all tested categories. Both sequences gave significantly different ADC mean values for two b values compared to when using eight b values (P<.05) suggesting larger error is present when using two b values. HASTE was shown to be an improvement over EPI in terms of repeatability, signal variation within a region of interest and standard deviation over the volunteer set. The improved accuracy of the ADC value in the HASTE sequence makes it potentially a more sensitive tumor detection technique.


Asunto(s)
Algoritmos , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Próstata/patología , Neoplasias de la Próstata/patología , Anciano , Análisis de Fourier , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA