Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Clin Infect Dis ; 78(5): 1313-1320, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38306491

RESUMEN

BACKGROUND: Sputum-based testing is a barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce sputum, and sputum processing increases assay complexity and cost. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. METHODS: From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at 2 health centers in Kampala, Uganda. We collected demographic and clinical information, sputum for TB testing (Xpert MTB/RIF Ultra and 2 liquid cultures), and tongue swabs for same-day quantitative polymerase chain reaction (qPCR) testing. We evaluated tongue swab qPCR diagnostic accuracy versus sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared 2 swab types (Copan FLOQSWAB and Steripack spun polyester). RESULTS: Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were diagnosed with human immunodeficiency virus, and 32.0% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% (95% confidence interval [CI]: 96.2-99.1) of participants. Tongue swab qPCR sensitivity was 92.6% (95% CI: 86.5 to 96.0) and specificity was 99.1% (95% CI: 96.9 to 99.8) versus microbiological reference standard. A single tongue swab recovered a 7-log range of TB copies, with a decreasing recovery trend among 4 serial swabs. Swab types performed equivalently. CONCLUSIONS: Tongue swabs are a promising alternative to sputum for molecular diagnosis of TB, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab-based TB diagnostics.


Asunto(s)
Mycobacterium tuberculosis , Reacción en Cadena en Tiempo Real de la Polimerasa , Sensibilidad y Especificidad , Manejo de Especímenes , Esputo , Lengua , Humanos , Femenino , Esputo/microbiología , Masculino , Uganda , Adulto , Lengua/microbiología , Manejo de Especímenes/métodos , Mycobacterium tuberculosis/genética , Mycobacterium tuberculosis/aislamiento & purificación , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Tuberculosis/diagnóstico , Tuberculosis/microbiología , Persona de Mediana Edad , Adulto Joven , Tuberculosis Pulmonar/diagnóstico , Tuberculosis Pulmonar/microbiología
2.
Malar J ; 21(1): 122, 2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35413904

RESUMEN

BACKGROUND: Microscopic examination of Giemsa-stained blood films remains the reference standard for malaria parasite detection and quantification, but is undermined by difficulties in ensuring high-quality manual reading and inter-reader reliability. Automated parasite detection and quantification may address this issue. METHODS: A multi-centre, observational study was conducted during 2018 and 2019 at 11 sites to assess the performance of the EasyScan Go, a microscopy device employing machine-learning-based image analysis. Sensitivity, specificity, accuracy of species detection and parasite density estimation were assessed with expert microscopy as the reference. Intra- and inter-device reliability of the device was also evaluated by comparing results from repeat reads on the same and two different devices. This study has been reported in accordance with the Standards for Reporting Diagnostic accuracy studies (STARD) checklist. RESULTS: In total, 2250 Giemsa-stained blood films were prepared and read independently by expert microscopists and the EasyScan Go device. The diagnostic sensitivity of EasyScan Go was 91.1% (95% CI 88.9-92.7), and specificity 75.6% (95% CI 73.1-78.0). With good quality slides sensitivity was similar (89.1%, 95%CI 86.2-91.5), but specificity increased to 85.1% (95%CI 82.6-87.4). Sensitivity increased with parasitaemia rising from 57% at < 200 parasite/µL, to ≥ 90% at > 200-200,000 parasite/µL. Species were identified accurately in 93% of Plasmodium falciparum samples (kappa = 0.76, 95% CI 0.69-0.83), and in 92% of Plasmodium vivax samples (kappa = 0.73, 95% CI 0.66-0.80). Parasite density estimates by the EasyScan Go were within ± 25% of the microscopic reference counts in 23% of slides. CONCLUSIONS: The performance of the EasyScan Go in parasite detection and species identification accuracy fulfil WHO-TDR Research Malaria Microscopy competence level 2 criteria. In terms of parasite quantification and false positive rate, it meets the level 4 WHO-TDR Research Malaria Microscopy criteria. All performance parameters were significantly affected by slide quality. Further software improvement is required to improve sensitivity at low parasitaemia and parasite density estimations. Trial registration ClinicalTrials.gov number NCT03512678.


Asunto(s)
Malaria Falciparum , Malaria , Pruebas Diagnósticas de Rutina/métodos , Humanos , Aprendizaje Automático , Malaria/diagnóstico , Malaria/parasitología , Malaria Falciparum/parasitología , Microscopía/métodos , Parasitemia/diagnóstico , Parasitemia/parasitología , Plasmodium falciparum , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Malar J ; 20(1): 110, 2021 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-33632222

RESUMEN

BACKGROUND: Manual microscopy remains a widely-used tool for malaria diagnosis and clinical studies, but it has inconsistent quality in the field due to variability in training and field practices. Automated diagnostic systems based on machine learning hold promise to improve quality and reproducibility of field microscopy. The World Health Organization (WHO) has designed a 55-slide set (WHO 55) for their External Competence Assessment of Malaria Microscopists (ECAMM) programme, which can also serve as a valuable benchmark for automated systems. The performance of a fully-automated malaria diagnostic system, EasyScan GO, on a WHO 55 slide set was evaluated. METHODS: The WHO 55 slide set is designed to evaluate microscopist competence in three areas of malaria diagnosis using Giemsa-stained blood films, focused on crucial field needs: malaria parasite detection, malaria parasite species identification (ID), and malaria parasite quantitation. The EasyScan GO is a fully-automated system that combines scanning of Giemsa-stained blood films with assessment algorithms to deliver malaria diagnoses. This system was tested on a WHO 55 slide set. RESULTS: The EasyScan GO achieved 94.3 % detection accuracy, 82.9 % species ID accuracy, and 50 % quantitation accuracy, corresponding to WHO microscopy competence Levels 1, 2, and 1, respectively. This is, to our knowledge, the best performance of a fully-automated system on a WHO 55 set. CONCLUSIONS: EasyScan GO's expert ratings in detection and quantitation on the WHO 55 slide set point towards its potential value in drug efficacy use-cases, as well as in some case management situations with less stringent species ID needs. Improved runtime may enable use in general case management settings.


Asunto(s)
Pruebas Diagnósticas de Rutina/métodos , Malaria Falciparum/diagnóstico , Microscopía/instrumentación , Plasmodium falciparum/aislamiento & purificación , Automatización de Laboratorios , Pruebas Diagnósticas de Rutina/instrumentación , Humanos , Malaria/diagnóstico , Plasmodium/aislamiento & purificación , Reproducibilidad de los Resultados , Organización Mundial de la Salud
4.
BMC Pulm Med ; 21(1): 78, 2021 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-33663453

RESUMEN

BACKGROUND: Supplemental oxygen is an essential treatment for childhood pneumonia but is often unavailable in low-resource settings or unreliable due to frequent and long-lasting power outages. We present a novel medium pressure reservoir (MPR) which delivers continuous oxygen to pediatric patients through power outages. METHODS: An observational case series pilot study assessing the capacity, efficacy and user appraisal of a novel MPR device for use in low-resource pediatric wards. We designed and tested a MPR in a controlled preclinical setting, established feasibility of the device in two rural Kenyan hospitals, and sought user feedback and satisfaction using a standardized questionnaire. RESULTS: Preclinical data showed that the MPR was capable of bridging power outages and delivering a continuous flow of oxygen to a simulated patient. The MPR was then deployed for clinical testing in nine pediatric patients at Ahero and Suba Hospitals. Power was unavailable for 2% of the total time observed due to 11 power outages (median 4.6 min, IQR 3.6-13.0 min) that occurred during treatment with the MPR. Oxygen flowrates remained constant across all 11 power outages. Feedback on the MPR was uniformly positive; all respondents indicated that the MPR was easy to use and provided clinically significant help to their patients. CONCLUSION: We present a MPR oxygen delivery device that has the potential to mitigate power insecurity and improve the standard of care for hypoxemic pediatric patients in resource-limited settings.


Asunto(s)
Hipoxia/terapia , Sistemas de Medicación en Hospital , Oxígeno/administración & dosificación , Preescolar , Países en Desarrollo , Equipos y Suministros de Hospitales , Estudios de Factibilidad , Femenino , Recursos en Salud/provisión & distribución , Humanos , Lactante , Kenia , Masculino , Oxígeno/provisión & distribución , Proyectos Piloto
5.
BMC Pulm Med ; 20(1): 230, 2020 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-32867735

RESUMEN

BACKGROUND: Oxygen is an essential therapy for hypoxemia but is scarce in low-income settings. Oxygen conserving devices optimize delivery, but to date have been designed for adults in high-income settings. Here we present the development and clinical pilot study of an oxygen-sparing nasal reservoir cannula (OSNRC) for pediatric use in low-income settings. METHODS: (1) Pre-clinical development of a novel OSNRC using a simulated respiratory circuit with metabolic simulator and anatomically accurate face-airway models. Simulated breathing waveforms were designed based on airway resistance, lung compliance, respiratory rate, and tidal volume of spontaneous breathing for three disease conditions. (2) Pilot, randomized, controlled, non-blinded, cross-over study of the OSNRC vs standard nasal cannula (SNC) among children hospitalized with hypoxemic pneumonia in Uganda. Eight children were randomized to OSNRC followed by SNC, and eight were randomized to SNC followed by OSNRC. RESULTS: The laboratory simulation showed that the OSNRC provided the same or higher fraction of inspired oxygen at approximately 2.5-times lower flow rate compared to SNC. The flow savings ratio exhibited a linear relationship with the OSNRC volume to tidal volume ratio with a slope that varied with breathing waveforms. The range of performance from different breathing waveforms defined a performance envelope of the OSNRC. Two mask sizes (30 mL and 50 mL) provided sufficient coverage for patients between the 3rd and 97th percentile in our targeted age range. In the clinical pilot study, the rise in capillary blood pCO2 was similar in the OSNRC and SNC groups, suggesting that the OSNRC was not associated with CO2 retention. There were no significant differences between OSNRC and SNC with respect to clinical adverse events, lactate levels, pH, and SpO2. The OSNRC group had a higher mean SpO2 than the SNC group (adjusted mean difference, 1.4, 95% confidence interval 1.1 to 1.8), showing oxygen delivery enhancement. CONCLUSION: The OSNRC enhances oxygen delivery without causing CO2 retention and appears to be well-tolerated by pediatric patients. If safety, efficacy and tolerability are confirmed in larger trials, this device has the potential to optimize oxygen delivery in children in low-resource settings, reducing the global burden of pediatric pneumonia. TRIAL REGISTRATION: The trial was retrospectively registered (International Standard Registered Clinical/Social Study Number (ISRCTN): 15216845 ; Date of registration: 15 July 2020).


Asunto(s)
Cánula , Hipoxia/terapia , Terapia por Inhalación de Oxígeno/instrumentación , Oxígeno/sangre , Neumonía/terapia , Preescolar , Estudios Cruzados , Femenino , Humanos , Hipoxia/etiología , Masculino , Nariz , Proyectos Piloto , Volumen de Ventilación Pulmonar , Uganda
6.
Malar J ; 17(1): 339, 2018 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-30253764

RESUMEN

BACKGROUND: Microscopic examination of Giemsa-stained blood films remains a major form of diagnosis in malaria case management, and is a reference standard for research. However, as with other visualization-based diagnoses, accuracy depends on individual technician performance, making standardization difficult and reliability poor. Automated image recognition based on machine-learning, utilizing convolutional neural networks, offers potential to overcome these drawbacks. A prototype digital microscope device employing an algorithm based on machine-learning, the Autoscope, was assessed for its potential in malaria microscopy. Autoscope was tested in the Iquitos region of Peru in 2016 at two peripheral health facilities, with routine microscopy and PCR as reference standards. The main outcome measures include sensitivity and specificity of diagnosis of malaria from Giemsa-stained blood films, using PCR as reference. METHODS: A cross-sectional, observational trial was conducted at two peripheral primary health facilities in Peru. 700 participants were enrolled with the criteria: (1) age between 5 and 75 years, (2) history of fever in the last 3 days or elevated temperature on admission, (3) informed consent. The main outcome measures included sensitivity and specificity of diagnosis of malaria from Giemsa-stained blood films, using PCR as reference. RESULTS: At the San Juan clinic, sensitivity of Autoscope for diagnosing malaria was 72% (95% CI 64-80%), and specificity was 85% (95% CI 79-90%). Microscopy performance was similar to Autoscope, with sensitivity 68% (95% CI 59-76%) and specificity 100% (95% CI 98-100%). At San Juan, 85% of prepared slides had a minimum of 600 WBCs imaged, thus meeting Autoscope's design assumptions. At the second clinic, Santa Clara, the sensitivity of Autoscope was 52% (95% CI 44-60%) and specificity was 70% (95% CI 64-76%). Microscopy performance at Santa Clara was 42% (95% CI 34-51) and specificity was 97% (95% CI 94-99). Only 39% of slides from Santa Clara met Autoscope's design assumptions regarding WBCs imaged. CONCLUSIONS: Autoscope's diagnostic performance was on par with routine microscopy when slides had adequate blood volume to meet its design assumptions, as represented by results from the San Juan clinic. Autoscope's diagnostic performance was poorer than routine microscopy on slides from the Santa Clara clinic, which generated slides with lower blood volumes. Results of the study reflect both the potential for artificial intelligence to perform tasks currently conducted by highly-trained experts, and the challenges of replicating the adaptiveness of human thought processes.


Asunto(s)
Pruebas Diagnósticas de Rutina/métodos , Malaria Falciparum/diagnóstico , Malaria Vivax/diagnóstico , Microscopía/métodos , Adolescente , Adulto , Anciano , Niño , Preescolar , Estudios Transversales , Pruebas Diagnósticas de Rutina/instrumentación , Humanos , Microscopía/instrumentación , Persona de Mediana Edad , Perú , Plasmodium falciparum/aislamiento & purificación , Plasmodium vivax/aislamiento & purificación , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
7.
medRxiv ; 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38585855

RESUMEN

Cough is a common and commonly ignored symptom of lung disease. Cough is often perceived as difficult to quantify, frequently self-limiting, and non-specific. However, cough has a central role in the clinical detection of many lung diseases including tuberculosis (TB), which remains the leading infectious disease killer worldwide. TB screening currently relies on self-reported cough which fails to meet the World Health Organization (WHO) accuracy targets for a TB triage test. Artificial intelligence (AI) models based on cough sound have been developed for several respiratory conditions, with limited work being done in TB. To support the development of an accurate, point-of-care cough-based triage tool for TB, we have compiled a large multi-country database of cough sounds from individuals being evaluated for TB. The dataset includes more than 700,000 cough sounds from 2,143 individuals with detailed demographic, clinical and microbiologic diagnostic information. We aim to empower researchers in the development of cough sound analysis models to improve TB diagnosis, where innovative approaches are critically needed to end this long-standing pandemic.

8.
medRxiv ; 2023 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-37645869

RESUMEN

Background: Reliance on sputum-based testing is a key barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce and sputum processing increases the complexity and cost of molecular assays. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. Methods: From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at two health centers in Kampala, Uganda. We collected routine demographic and clinical information, sputum for routine TB testing (one Xpert MTB/RIF Ultra® and two liquid cultures), and up to four tongue swabs for same-day qPCR. We evaluated tongue swab qPCR diagnostic accuracy in reference to sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared two swab types (Copan FLOQSWAB® and Steripack® spun polyester swabs). Results: Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were living with HIV (PLHIV) and 32.3% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% [96.2-99.1] of participants. Tongue swab qPCR sensitivity was 91.0% [84.6-94.9] and specificity 98.9% [96.2-99.8] vs. microbiological reference standard (MRS). A single tongue swab recovered a seven-log range of TB copies, with a decreasing recovery trend among four serial swabs. We found no difference between swab types. Conclusions: Tongue swabs show promise as an alternative to sputum for TB diagnosis, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab-based TB diagnostics.

9.
J Ethn Subst Abuse ; 11(1): 22-47, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22381121

RESUMEN

Group differences in four aspects of alcohol consumption behaviors were examined in non-traditional college students (N = 1092; 828 women and 264 men) attending a large, non-residential, urban university. Findings demonstrated several differences between traditional and non-traditional students' drinking behaviors. Specifically, non-traditional students are more likely to abstain; Caucasians are more apt to drink in isolation and experience negative social consequences of drinking; Hispanic and African American women control their alcohol consumption better; and African American men are more likely to experience antisocial consequences due to drinking. These findings have implications for education and prevention efforts targeting non-traditional college students.


Asunto(s)
Consumo de Bebidas Alcohólicas/etnología , Consumo de Bebidas Alcohólicas/epidemiología , Estudiantes/estadística & datos numéricos , Universidades , Adolescente , Adulto , Negro o Afroamericano/estadística & datos numéricos , Factores de Edad , Femenino , Hispánicos o Latinos/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Factores Sexuales , Aislamiento Social , Población Urbana , Población Blanca/estadística & datos numéricos , Adulto Joven
10.
Sci Rep ; 12(1): 16972, 2022 10 10.
Artículo en Inglés | MEDLINE | ID: mdl-36216964

RESUMEN

Tuberculosis (TB) remains a significant cause of mortality worldwide. Metagenomic next-generation sequencing has the potential to reveal biomarkers of active disease, identify coinfection, and improve detection for sputum-scarce or culture-negative cases. We conducted a large-scale comparative study of 428 plasma, urine, and oral swab samples from 334 individuals from TB endemic and non-endemic regions to evaluate the utility of a shotgun metagenomic DNA sequencing assay for tuberculosis diagnosis. We found that the composition of the control population had a strong impact on the measured performance of the diagnostic test: the use of a control population composed of individuals from a TB non-endemic region led to a test with nearly 100% specificity and sensitivity, whereas a control group composed of individuals from TB endemic regions exhibited a high background of nontuberculous mycobacterial DNA, limiting the diagnostic performance of the test. Using mathematical modeling and quantitative comparisons to matched qPCR data, we found that the burden of Mycobacterium tuberculosis DNA constitutes a very small fraction (0.04 or less) of the total abundance of DNA originating from mycobacteria in samples from TB endemic regions. Our findings suggest that the utility of a minimally invasive metagenomic sequencing assay for pulmonary tuberculosis diagnostics is limited by the low burden of M. tuberculosis and an overwhelming biological background of nontuberculous mycobacterial DNA.


Asunto(s)
Mycobacterium tuberculosis , Tuberculosis , Biomarcadores , ADN , Humanos , Mycobacterium tuberculosis/genética , Micobacterias no Tuberculosas/genética , Sensibilidad y Especificidad , Análisis de Secuencia de ADN , Esputo/microbiología , Tuberculosis/diagnóstico , Tuberculosis/microbiología
11.
PLoS One ; 17(8): e0273106, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36037183

RESUMEN

The evaluation of protein antigens as putative serologic biomarkers of infection has increasingly shifted to high-throughput, multiplex approaches such as the protein microarray. In vitro transcription/translation (IVTT) systems-a similarly high-throughput protein expression method-are already widely utilised in the production of protein microarrays, though purified recombinant proteins derived from more traditional whole cell based expression systems also play an important role in biomarker characterisation. Here we have performed a side-by-side comparison of antigen-matched protein targets from an IVTT and purified recombinant system, on the same protein microarray. The magnitude and range of antibody responses to purified recombinants was found to be greater than that of IVTT proteins, and responses between targets from different expression systems did not clearly correlate. However, responses between amino acid sequence-matched targets from each expression system were more closely correlated. Despite the lack of a clear correlation between antigen-matched targets produced in each expression system, our data indicate that protein microarrays produced using either method can be used confidently, in a context dependent manner, though care should be taken when comparing data derived from contrasting approaches.


Asunto(s)
Malaria Falciparum , Plasmodium falciparum , Anticuerpos Antiprotozoarios , Formación de Anticuerpos , Antígenos de Protozoos , Biomarcadores/metabolismo , Humanos , Análisis por Matrices de Proteínas , Proteómica , Proteínas Recombinantes/metabolismo
12.
Am J Trop Med Hyg ; 106(3): 850-852, 2022 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-35026727

RESUMEN

Rapid diagnostic tests (RDTs) for Plasmodium falciparum commonly detect histidine-rich protein 2 (HRP-2), but HRP-2 deletions are increasingly recognized. We evaluated a prototype test detecting parasite lactate dehydrogenase (pLDH) and compared it to commercially available RDTs at a health facility in Uganda, using quantitative polymerase chain reaction as a gold standard. The prototype pLDH test had a high sensitivity for infections with at least 100 parasites/µL (98%), comparable to HRP-2, and greater than an existing pLDH RDT (89%). Specificity for the prototype test was 99.5%, which is greater than the HRP-2 tests (93-95%). Therefore, the prototype pLDH test may be an attractive alternative malaria diagnostic.


Asunto(s)
Malaria Falciparum , Malaria , Antígenos de Protozoos/análisis , Pruebas Diagnósticas de Rutina , Humanos , L-Lactato Deshidrogenasa/análisis , Malaria/diagnóstico , Malaria Falciparum/diagnóstico , Malaria Falciparum/parasitología , Microscopía , Plasmodium falciparum , Reacción en Cadena de la Polimerasa , Proteínas Protozoarias/genética , Proteínas Protozoarias/metabolismo , Sensibilidad y Especificidad , Uganda
13.
PLoS One ; 16(8): e0256352, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34403456

RESUMEN

Rapid tests for SARS-COV-2 infection are important tools for pandemic control, but current rapid tests are based on proprietary designs and reagents. We report clinical validation results of an open-access lateral flow assay (OA-LFA) design using commercially available materials and reagents, along with RT-qPCR and commercially available comparators (BinaxNOW® and Sofia®). Adult patients with suspected COVID-19 based on clinical signs and symptoms, and with symptoms ≤7 days duration, underwent anterior nares (AN) sampling for the OA-LFA, Sofia®, BinaxNOW ™, and RT-qPCR, along with nasopharyngeal (NP) RT-qPCR. Results indicate a positive predictive agreement with NP sampling as 69% (60% -78%) OA-LFA, 74% (64% - 82%) Sofia®, and 82% (73% - 88%) BinaxNOW™. The implication for these results is that we provide an open-access LFA design that meets the minimum WHO target product profile for a rapid test, that virtually any diagnostic manufacturer could produce.


Asunto(s)
Antígenos Virales/análisis , COVID-19/diagnóstico , Inmunoensayo , SARS-CoV-2/metabolismo , Área Bajo la Curva , COVID-19/virología , Humanos , Nasofaringe/virología , Sistemas de Atención de Punto , ARN Viral/análisis , ARN Viral/metabolismo , Curva ROC , Reacción en Cadena en Tiempo Real de la Polimerasa , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad
14.
PLoS One ; 16(7): e0254156, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34310609

RESUMEN

Detection of tuberculosis at the point-of-care (POC) is limited by the low sensitivity of current commercially available tests. We describe a diagnostic accuracy field evaluation of a prototype urine Tuberculosis Lipoarabinomannan Lateral Flow Assay (TB-LAM LFA) in both HIV-positive and HIV-negative patients using fresh samples with sensitivity and specificity as the measures of accuracy. This prototype combines a proprietary concentration system with a sensitive LFA. In a prospective study of 292 patients with suspected pulmonary tuberculosis in Uganda, the clinical sensitivity and specificity was compared against a microbiological reference standard including sputum Xpert MTB/RIF Ultra and solid and liquid culture. TB-LAM LFA had an overall sensitivity of 60% (95%CI 51-69%) and specificity of 80% (95%CI 73-85%). When comparing HIV-positive (N = 86) and HIV-negative (N = 206) patients, there was no significant difference in sensitivity (sensitivity difference 8%, 95%CI -11% to +24%, p = 0.4351) or specificity (specificity difference -9%, 95%CI -24% to +4%, p = 0.2051). Compared to the commercially available Alere Determine TB-LAM Ag test, the TB-LAM LFA prototype had improved sensitivity in both HIV-negative (difference 49%, 95%CI 37% to 59%, p<0.0001) and HIV-positive patients with CD4+ T-cell counts >200cells/µL (difference 59%, 95%CI 32% to 75%, p = 0.0009). This report is the first to show improved performance of a urine TB LAM test for HIV-negative patients in a high TB burden setting. We also offer potential assay refinement solutions that may further improve sensitivity and specificity.


Asunto(s)
Infecciones por VIH/orina , Seropositividad para VIH/orina , Lipopolisacáridos/orina , Tuberculosis/orina , Adulto , Femenino , VIH/patogenicidad , Infecciones por VIH/complicaciones , Infecciones por VIH/microbiología , Infecciones por VIH/virología , Seropositividad para VIH/microbiología , Seropositividad para VIH/virología , Humanos , Masculino , Pruebas en el Punto de Atención , Esputo/microbiología , Esputo/virología , Tuberculosis/complicaciones , Tuberculosis/microbiología , Tuberculosis/virología , Uganda/epidemiología , Adulto Joven
15.
PLoS One ; 16(5): e0251422, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33999938

RESUMEN

Oral swab analysis (OSA) has been shown to detect Mycobacterium tuberculosis (MTB) DNA in patients with pulmonary tuberculosis (TB). In previous analyses, qPCR testing of swab samples collected from tongue dorsa was up to 93% sensitive relative to sputum GeneXpert, when 2 swabs per patient were tested. The present study modified sample collection methods to increase sample biomass and characterized the viability of bacilli present in tongue swabs. A qPCR targeting conserved bacterial ribosomal rRNA gene (rDNA) sequences was used to quantify bacterial biomass in samples. There was no detectable reduction in total bacterial rDNA signal over the course of 10 rapidly repeated tongue samplings, indicating that swabs collect only a small portion of the biomass available for testing. Copan FLOQSwabs collected ~2-fold more biomass than Puritan PurFlock swabs, the best brand used previously (p = 0.006). FLOQSwabs were therefore evaluated in patients with possible TB in Uganda. A FLOQSwab was collected from each patient upon enrollment (Day 1) and, in a subset of sputum GeneXpert Ultra-positive patients, a second swab was collected on the following day (Day 2). Swabs were tested for MTB DNA by manual IS6110-targeted qPCR. Relative to sputum GeneXpert Ultra, single-swab sensitivity was 88% (44/50) on Day 1 and 94.4% (17/18) on Day 2. Specificity was 79.2% (42/53). Among an expanded sample of Ugandan patients, 62% (87/141) had colony-forming bacilli in their tongue dorsum swab samples. These findings will help guide further development of this promising TB screening method.


Asunto(s)
Mycobacterium tuberculosis/aislamiento & purificación , Tuberculosis Pulmonar/diagnóstico , Adolescente , Adulto , ADN Ribosómico/genética , Femenino , Genes Bacterianos , Humanos , Masculino , Mycobacterium tuberculosis/genética , Reacción en Cadena de la Polimerasa , ARN Bacteriano/genética , ARN Ribosómico/genética , Manejo de Especímenes , Tuberculosis Pulmonar/epidemiología , Tuberculosis Pulmonar/microbiología , Uganda/epidemiología , Adulto Joven
16.
Int J Behav Nutr Phys Act ; 7: 25, 2010 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-20350316

RESUMEN

OBJECTIVE: To improve an existing measure of fruit and vegetable intake self efficacy by including items that varied on levels of difficulty, and testing a corresponding measure of water intake self efficacy. DESIGN: Cross sectional assessment. Items were modified to have easy, moderate and difficult levels of self efficacy. Classical test theory and item response modeling were applied. SETTING: One middle school at each of seven participating sites (Houston TX, Irvine CA, Philadelphia PA, Pittsburg PA, Portland OR, rural NC, and San Antonio TX). SUBJECTS: 714 6th grade students. RESULTS: Adding items to reflect level (low, medium, high) of self efficacy for fruit and vegetable intake achieved scale reliability and validity comparable to existing scales, but the distribution of items across the latent variable did not improve. Selecting items from among clusters of items at similar levels of difficulty along the latent variable resulted in an abbreviated scale with psychometric characteristics comparable to the full scale, except for reliability. CONCLUSIONS: The abbreviated scale can reduce participant burden. Additional research is necessary to generate items that better distribute across the latent variable. Additional items may need to tap confidence in overcoming more diverse barriers to dietary intake.

17.
Pediatr Pulmonol ; 55(4): 1043-1049, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32040889

RESUMEN

INTRODUCTION: Pneumonia is the leading cause of death globally in children. Supplemental oxygen reduces mortality but is not available in many low-resource settings. Inadequate power supply to drive oxygen concentrators is a major contributor to this failure. The objectives of our study were to (a) assess the availability of therapeutic oxygen; (b) evaluate the reliability of the electrical supply; and (c) investigate the effects of suboptimal oxygen delivery on patient outcomes in selected healthcare facilities in rural Kenya. MATERIALS AND METHODS: A cross-sectional descriptive study on oxygen availability and descriptive case series of Kenyan children and youth hospitalized with hypoxemia. RESULTS: Two of 11 facilities had no oxygen equipment and nine facilities had at least one concentrator or cylinder. Facilities had a median of seven power interruptions per week (range: 2-147). The median duration of the power outage was 17 minutes and the longest was more than 6 days. The median proportion of time without power was out 7% (range: 1%-58%). Fifty-seven patients hospitalized with hypoxemia (median oxygen saturation 85% [interquartile range {IQR}: 82-87]) were included in our case series. Patients received supplemental oxygen for a median duration of 4.6 hours (IQR: 3.0-7.8). Eighteen patients (32%) faced an oxygen interruption of the median duration of 11 minutes (IQR: 9-20). A back-up cylinder was used in 5/18 (28%) cases. The case fatality rate was 11/57 (19%). CONCLUSION: Mortality due to hypoxemia remains unacceptably high in low-resource healthcare facilities and may be associated with oxygen insecurity, related to lack of equipment and/or reliable power.


Asunto(s)
Hipoxia/mortalidad , Oxígeno , Adolescente , Niño , Estudios Transversales , Instituciones de Salud , Recursos en Salud , Humanos , Lactante , Kenia/epidemiología , Neumonía/terapia , Reproducibilidad de los Resultados , Proyectos de Investigación , Población Rural
18.
Int J Behav Nutr Phys Act ; 6: 20, 2009 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-19335875

RESUMEN

BACKGROUND: Theoretically, increased levels of physical activity self-efficacy (PASE) should lead to increased physical activity, but few studies have reported this effect among youth. This failure may be at least partially attributable to measurement limitations. In this study, Item Response Modeling (IRM) was used to develop new physical activity and sedentary behavior change self-efficacy scales. The validity of the new scales was compared with accelerometer assessments of physical activity and sedentary behavior. METHODS: New PASE and sedentary behavior change (TV viewing, computer video game use, and telephone use) self-efficacy items were developed. The scales were completed by 714, 6th grade students in seven US cities. A limited number of participants (83) also wore an accelerometer for five days and provided at least 3 full days of complete data. The new scales were analyzed using Classical Test Theory (CTT) and IRM; a reduced set of items was produced with IRM and correlated with accelerometer counts per minute and minutes of sedentary, light and moderate to vigorous activity per day after school. RESULTS: The PASE items discriminated between high and low levels of PASE. Full and reduced scales were weakly correlated (r = 0.18) with accelerometer counts per minute after school for boys, with comparable associations for girls. Weaker correlations were observed between PASE and minutes of moderate to vigorous activity (r = 0.09 - 0.11). The uni-dimensionality of the sedentary scales was established by both exploratory factor analysis and the fit of items to the underlying variable and reliability was assessed across the length of the underlying variable with some limitations. The reduced sedentary behavior scales had poor reliability. The full scales were moderately correlated with light intensity physical activity after school (r = 0.17 to 0.33) and sedentary behavior (r = -0.29 to -0.12) among the boys, but not for girls. CONCLUSION: New physical activity and sedentary behavior change self-efficacy scales have fewer items than classical test theory derived alternatives and have reasonable validity for boys, but more work is needed to develop comparable scales for girls. Fitting the items to a underlying variable could be useful in tailoring interventions to this scale.

19.
J Nutr Educ Behav ; 39(1): 2-7, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17276320

RESUMEN

OBJECTIVE: To determine the reliability and validity of a questionnaire measuring fruit and vegetable (FV) self-efficacy and social norms during school lunch among 5th graders. DESIGN: In this cross-sectional study, students completed lunch food records and a psychosocial questionnaire measuring school lunch FV self-efficacy and social norms regarding consumption during the fall and spring semesters. Test-retest reliability was assessed between fall and spring semesters. The measurement model was cross-validated in the spring data. SETTING: One middle school in Houston, Texas. PARTICIPANTS: 275 fifth graders in the 1998 fall semester and 262 of these fifth graders in the 1999 spring semester. MAIN OUTCOME MEASURES: FV consumption and psychosocial variables. ANALYSES: Principal components analyses, confirmatory factor analyses and bivariate correlations. RESULTS: Three scales were identified: Fruit Self-Efficacy, Vegetable Self-Efficacy, and FV Social Norms. FV self-efficacy were positively correlated with low-fat vegetable and fruit consumption. Social norms were positively correlated with total vegetable, low-fat vegetable, fruit and total FV consumption. CONCLUSIONS AND IMPLICATIONS: Self-efficacy and norms for eating FV at school lunch are related to lunch FV consumption. Increasing self-efficacy and social norms about consuming FV at school appears to be important targets to improve FV consumption.


Asunto(s)
Frutas , Autoeficacia , Encuestas y Cuestionarios/normas , Verduras , Niño , Estudios Transversales , Análisis Factorial , Femenino , Humanos , Masculino , Análisis de Componente Principal , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
Nutr Rev ; 64(4): 153-74, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16673752

RESUMEN

Four mechanisms were reviewed to explain the possible association between sweetened beverages and increased overweight or obesity: excess caloric intake, glycemic index and glycemic load, lack of effect of liquid calories on satiety, and displacement of milk. The findings were inconsistent across studies. The strongest support was for the excess caloric intake hypothesis, but the findings were not conclusive. Assigning possible links between sweetened beverage consumption and adiposity requires research that compares and contrasts specific mechanisms, especially in populations at risk for obesity, while controlling for likely confounding variables.


Asunto(s)
Adiposidad/efectos de los fármacos , Bebidas , Sacarosa en la Dieta/efectos adversos , Ingestión de Energía , Obesidad/etiología , Obesidad/metabolismo , Adiposidad/genética , Sacarosa en la Dieta/administración & dosificación , Ingestión de Energía/efectos de los fármacos , Ingestión de Energía/genética , Predisposición Genética a la Enfermedad , Índice Glucémico/efectos de los fármacos , Índice Glucémico/genética , Humanos , Insulina/metabolismo , Secreción de Insulina , Leptina/metabolismo , Obesidad/epidemiología , Obesidad/genética , Obesidad/fisiopatología , Factores de Riesgo , Respuesta de Saciedad/efectos de los fármacos , Edulcorantes/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA