Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Vasc Interv Radiol ; 35(7): 1022-1030.e4, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38599280

RESUMEN

PURPOSE: To evaluate the performance of a prototype flexible transbronchial cryoprobe compared with that of percutaneous transthoracic cryoablation and to define cone-beam computed tomography (CT) imaging and pathology cryolesion features in an in vivo swine model. MATERIALS AND METHODS: Transbronchial cryoablation was performed with a prototype flexible cryoprobe (3 central and 3 peripheral lung ablations in 3 swine) and compared with transthoracic cryoablation performed with a commercially available rigid cryoprobe (2 peripheral lung ablations in 1 swine). Procedural time and cryoablation success rates for endobronchial navigation and cryoneedle deployment were measured. Intraoperative cone-beam CT imaging features of cryolesions were characterized and correlated with gross pathology and hematoxylin and eosin-stained sections of the explanted cryolesions. RESULTS: The flexible cryoprobe was successfully navigated and delivered to each target through a steerable guiding sheath (6/6). At 4 minutes after ablation, 5 of 6 transbronchial and 2 of 2 transthoracic cryolesions were visible on cone-beam CT. The volumes on cone-beam CT images were 55.5 cm3 (SE ± 8.0) for central transbronchial ablations (n = 2), 72.5 cm3 (SE ± 8.1) for peripheral transbronchial ablations (n = 3), and 79.5 cm3 (SE ±11.6) for peripheral transthoracic ablations (n = 2). Pneumothorax developed in 1 animal after transbronchial ablation and during ablation in the transthoracic cryoablation. Images of cryoablation zones on cone-beam CT correlated well with the matched gross pathology and histopathology sections of the cryolesions. CONCLUSIONS: Transbronchial cryoablation with a flexible cryoprobe, delivered through a steerable guiding sheath, is feasible. Transbronchial cryoablation zones are imageable with cone-beam CT, with gross pathology and histopathology similar to those of transthoracic cryoablation.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Criocirugía , Diseño de Equipo , Animales , Criocirugía/instrumentación , Tomografía Computarizada de Haz Cónico/instrumentación , Porcinos , Radiografía Intervencional/instrumentación , Pulmón/cirugía , Pulmón/diagnóstico por imagen , Pulmón/patología , Modelos Animales , Broncoscopía/instrumentación , Sus scrofa
2.
J Vasc Interv Radiol ; 33(3): 316-323.e4, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34800622

RESUMEN

PURPOSE: To characterize the hepatic and abdominal angiographic anatomy of woodchucks and vascular changes associated with hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Twenty-nine woodchucks (23 with viral-associated HCC, 6 without) underwent multiphasic computed tomography (CT). Fourteen woodchucks (8 with HCC) also underwent diagnostic angiography. Hepatic arterial diameters were measured on the CT scans. Woodchucks were divided into 3 groups: non-tumor-bearing, largest tumor supplied by the right hepatic artery (RHA), and largest tumor supplied by the left hepatic artery (LHA). Statistical analysis with a repeated measures model was performed to determine the effects of tumor location (right, left), vessel measured (RHA, LHA), and interaction between the 2 on vessel diameter. Lobar arteries supplying HCC were compared with those that did not. RESULTS: CT anatomy and normal and variant vascular anatomy were defined. In woodchucks with HCC, LHA and RHA supplying tumors had mean diameters of 2.0 mm ± 0.3 and 1.6 mm ± 0.3 versus 1.5 mm ± 0.3 and 1.1 mm ± 0.2 for non-tumor-supplying arteries (P = .0002 and P < .0001), respectively. Lobar arteries supplying tumors were similarly ectatic. The right lateral lobe artery had the most profound increase in the mean diameter when supplying tumors, measuring 1.7 mm ± 0.1 versus 1.0 mm ± 0.1 in the non-tumor-supplying artery (P < .0001). There were no differences in the diameters of the aorta and celiac, common, and proper hepatic arteries between tumor- and non-tumor-bearing woodchucks. An angiographic atlas of the abdominal vessels was generated. CONCLUSIONS: HCC tumoral vasculature in woodchucks was ectatic compared with normal vasculature. This phenomenon recapitulates human HCC and may facilitate investigation of transcatheter and drug delivery therapies in an HCC animal model.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Abdomen , Angiografía/métodos , Animales , Carcinoma Hepatocelular/patología , Arteria Hepática/patología , Humanos , Neoplasias Hepáticas/patología , Marmota , Pelvis
3.
J Vasc Interv Radiol ; 31(12): 2122-2131, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33012647

RESUMEN

PURPOSE: To evaluate the accuracy of cone-beam computed tomography (CT)-based augmented fluoroscopy (AF) image guidance for endobronchial navigation to peripheral lung targets. METHODS: Prototypic endobronchial navigation AF software that superimposed segmented airways, targets, and pathways based on cone-beam CT onto fluoroscopy images was evaluated ex vivo in fixed swine lungs and in vivo in healthy swine (n = 4) without a bronchoscope. Ex vivo and in vivo (n = 3) phase 1 experiments used guide catheters and AF software version 1, whereas in vivo phase 2 (n = 1) experiments also used an endovascular steerable guiding sheath, upgraded AF software version 2, and lung-specific low-radiation-dose protocols. First-pass navigation success was defined as catheter delivery into a targeted airway segment solely using AF, with second-pass success defined as reaching the targeted segment by using updated AF image guidance based on confirmatory cone-beam CT. Secondary outcomes were navigation error, navigation time, radiation exposure, and preliminary safety. RESULTS: First-pass success was 100% (10/10) ex vivo and 19/24 (79%) and 11/15 (73%) for in vivo phases 1 and 2, respectively. Phase 2 second-pass success was 4/4 (100%). Navigation errors were 2.2 ± 1.2 mm ex vivo and 4.9 ± 3.2 mm and 4.0 ± 2.6 mm for in vivo phases 1 and 2, respectively. No major device-related complications were observed in the in vivo experiments. CONCLUSIONS: Endobronchial navigation is feasible and accurate with cone-beam CT-based AF image guidance. AF can guide endobronchial navigation with endovascular catheters and steerable guiding sheaths to peripheral lung targets, potentially overcoming limitations associated with bronchoscopy.


Asunto(s)
Cateterismo/instrumentación , Catéteres , Tomografía Computarizada de Haz Cónico/instrumentación , Pulmón/diagnóstico por imagen , Fantasmas de Imagen , Radiografía Intervencional/instrumentación , Animales , Estudios de Factibilidad , Fluoroscopía/instrumentación , Masculino , Modelos Animales , Interpretación de Imagen Radiográfica Asistida por Computador , Sus scrofa
4.
J Vasc Interv Radiol ; 31(5): 812-819.e1, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32107125

RESUMEN

PURPOSE: To assess the feasibility of transarterial chemoembolization with drug-eluting embolic (DEE) microspheres in a woodchuck model of hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Nine woodchucks were studied: 4 normal animals and 5 animals infected with woodchuck hepatitis virus in which HCC had developed. Three animals with HCC underwent multidetector CT. A 3-F sheath was introduced into the femoral artery, and the hepatic arteries were selectively catheterized with 2.0-2.4-F microcatheters. Normal animals underwent diagnostic angiography and bland embolization. Animals with HCC underwent DEE transarterial chemoembolization with 70-150-µm radiopaque microspheres loaded with 37.5 mg doxorubicin per milliliter. Cone-beam CT and multidetector CT were performed. Following euthanasia, explanted livers underwent micro-CT, histopathologic examination, and fluorescence imaging of doxorubicin. RESULTS: The tumors were hypervascular and supplied by large-caliber tortuous vessels, with arteriovenous shunts present in 2 animals. There was heterogeneous enhancement on multidetector CT with areas of necrosis. Six tumors were identified. The most common location was the right medial lobe (n = 3). Mean tumor volume was 30.7 cm3 ± 12.3. DEE chemoembolization of tumors was achieved. Excluding the 2 animals with arteriovenous shunts, the mean volume of DEE microspheres injected was 0.49 mL ± 0.17. Fluorescence imaging showed diffusion of doxorubicin from the DEE microspheres into the tumor. CONCLUSIONS: Woodchuck HCC shares imaging appearances and biologic characteristics with human HCC. Selective catheterization and DEE chemoembolization may similarly be performed. Woodchucks may be used to model interventional therapies and possibly characterize radiologic-pathologic correlations.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica , Doxorrubicina/administración & dosificación , Neoplasias Hepáticas/terapia , Angiografía de Substracción Digital , Animales , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/virología , Tomografía Computarizada de Haz Cónico , Modelos Animales de Enfermedad , Femenino , Hepatitis B/complicaciones , Hepatitis B/virología , Virus de la Hepatitis B de la Marmota/patogenicidad , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/virología , Masculino , Marmota , Microscopía Fluorescente , Microesferas , Tomografía Computarizada Multidetector , Carga Tumoral
5.
Radiology ; 289(2): 396-404, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30106347

RESUMEN

Purpose To correlate bead location and attenuation on CT images with the quantity and distribution of drug delivered to the liver following transarterial chemoembolization (TACE) with radiopaque drug-eluting beads (DEB) in a rabbit tumor model. Materials and Methods All procedures were performed with a protocol approved by the Institutional Animal Care and Use Committee. TACE was performed in rabbits (n = 4) bearing VX2 liver tumors by using radiopaque DEB (70-150 µm) loaded with doxorubicin (DOX). Livers were resected 1 hour after embolization, immediately frozen, and cut by using liver-specific three-dimensional-printed molds for colocalization of liver specimens and CT imaging. DOX penetration into tissue surrounding beads was evaluated with fluorescence microscopy. DOX levels in liver specimens were predicted by using statistical models correlating DOX content measured in tissue with bead volume and attenuation measured on CT images. Model predictions were then compared with actual measured DOX concentrations to assess the models' predictive power. Results Eluted DOX remained in close proximity (<600 µm) to beads in the liver 1 hour after TACE. Bead volume and attenuation measured on CT images demonstrated positive linear correlations (0.950 and 0.965, respectively) with DOX content in liver specimens. DOX content model predictions based on CT images were accurate compared with actual liver DOX levels at 1 hour. Conclusion CT may be used to estimate drug dose delivery and distribution in the liver following transarterial chemoembolization (TACE) with doxorubicin-loaded radiopaque drug-eluting beads (DEB). Although speculative, this informational map might be helpful in planning and understanding the spatial effects of TACE with DEB. © RSNA, 2018.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Quimioembolización Terapéutica/métodos , Doxorrubicina/administración & dosificación , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Tomografía Computarizada por Rayos X/métodos , Animales , Modelos Animales de Enfermedad , Sistemas de Liberación de Medicamentos , Hígado/diagnóstico por imagen , Microesferas , Conejos
6.
J Vasc Interv Radiol ; 29(4): 568-574, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29500000

RESUMEN

PURPOSE: To determine the true distribution of radiopaque beads (ROBs) after hepatic embolization in swine as imaged by micro-computed tomography (microCT) compared with in vivo cone-beam computerized tomography (CT) imaged at different kVp settings. MATERIALS AND METHODS: Swine (n = 3) underwent hepatic transarterial embolization (n = 6) with the use of 70-150-µm ROBs under fluoroscopic guidance. After stasis, in vivo cone-beam CT was performed at 120, 100, and 80 kVp. The animal was euthanized, the liver resected, and microCT with 17 µm resolution performed on embolized tissue samples. The resulting cone-beam CT and microCT data were segmented and registered. Total vessel length, minimum volume-enclosing ellipsoid (MVEE), and number of independent volumes were measured. Maximum-intensity projections (MIPs) were generated for each cone-beam CT. RESULTS: Metrics for all cone-beam CT segmentations differed significantly from microCT segmentations. Segmentations at 80 kVp presented significantly greater vessel length, MVEE, and number of independent volumes compared with 100 kVp and 120 kVp. In addition, 100 kVp segmentations presented significantly greater vessel length than 120 kVp. MIPs presented greater visualization than cone-beam CT segmentations and improved as kVp decreased. CONCLUSIONS: The full ROB distribution was more extensive than was apparent on cone-beam CT. Quantitative measures of embolic distribution demonstrated significantly better correlation with microCT with decreasing kVp. Similarly, qualitative analysis of MIPs showed improved visualization of beads with decreasing kVp. These findings demonstrate the clinical value of 80 kVp and 100 kVp protocols in the imaging of radiopaque embolizations compared with 120 kVp. However, considerations on X-ray penetration and dose may favor use of 100 kVp imaging over 80 kVp.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Embolización Terapéutica/instrumentación , Hígado/irrigación sanguínea , Microtomografía por Rayos X/métodos , Animales , Fluoroscopía , Microesferas , Modelos Animales , Porcinos
7.
Int J Hyperthermia ; 33(7): 733-740, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28540814

RESUMEN

PURPOSE: To evaluate lyso-thermosensitive liposomal doxorubicin (LTLD, ThermoDox®) in combination with loco-regional mild hyperthermia (HT) for targeted drug delivery to the bladder wall and potential treatment of bladder cancer. MATERIAL AND METHODS: Porcine in vivo studies were performed with the following groups: (i) intravenous (IV) LTLD with hyperthermia (LTLD + HT); (ii) IV doxorubicin (DOX) with hyperthermia (IV DOX + HT) and (iii) IV LTLD without hyperthermia (LTLD - HT). Drug formulations were delivered via 30 min IV infusion coinciding with 1-h bladder irrigation (45 °C water for HT groups, 37 °C for non-HT group), followed by immediate bladder resection. DOX concentrations were measured in consecutive sections parallel to the bladder lumen by liquid chromatography following drug extraction. Computer models were developed to simulate tissue heating and drug release from LTLD. RESULTS: Comparing mean DOX concentrations at increasing depths from the lumen to outer surface of the bladder wall, the ranges for LTLD + HT, IV DOX + HT and LTLD - HT, respectively, were 20.32-3.52 µg/g, 2.34-0.61 µg/g and 2.18-0.51 µg/g. The average DOX concentrations in the urothelium/lamina and muscularis, respectively, were 9.7 ± 0.67 and 4.09 ± 0.81 µg/g for IV LTLD + HT, 1.2 ± 0.39 and 0.86 ± 0.24 µg/g for IV DOX + HT, and 1.15 ± 0.38 and 0.62 ± 0.15 µg/g for LTLD - HT. Computational model results were similar to measured DOX levels and suggest adequate temperatures were reached within the bladder wall for drug release from LTLD. CONCLUSIONS: Doxorubicin accumulation and distribution within the bladder wall was achieved at concentrations higher than with free IV doxorubicin by mild bladder hyperthermia combined with systemic delivery of LTLD.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Doxorrubicina/análogos & derivados , Sistemas de Liberación de Medicamentos , Hipertermia Inducida , Animales , Antibióticos Antineoplásicos/farmacocinética , Terapia Combinada , Doxorrubicina/administración & dosificación , Doxorrubicina/farmacocinética , Femenino , Polietilenglicoles/administración & dosificación , Polietilenglicoles/farmacocinética , Porcinos , Vejiga Urinaria/metabolismo , Neoplasias de la Vejiga Urinaria/terapia
8.
bioRxiv ; 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39282453

RESUMEN

Intratumoral injections often lack visibility, leading to unpredictable outcomes such as incomplete tumor coverage, off-target drug delivery and systemic toxicities. This study investigated an ultrasound (US) and x-ray imageable thermosensitive hydrogel based on poloxamer 407 (POL) percutaneously delivered in a healthy swine model. The primary objective was to assess the 2D and 3D distribution of the hydrogel within tissue across three different needle devices and injection sites: liver, kidney, and intercostal muscle region. Secondly, pharmacokinetics of POL loaded with doxorubicin (POLDOX) were evaluated and compared to free doxorubicin injection (DOXSoln) with a Single End Hole Needle. Utilizing 2D and 3D morphometrics from US and x-ray imaging techniques such as Computed Tomography (CT) and Cone Beam CT (CBCT), we monitored the localization and leakage of POLDOX over time. Relative iodine concentrations measured with CBCT following incorporation of an iodinated contrast agent in POL indicated potential drug diffusion and advection transport. Furthermore, US imaging revealed temporal changes, suggesting variations in acoustic intensity, heterogeneity, and echotextures. Notably, 3D reconstruction of the distribution of POL and POLDOX from 2D ultrasound frames was achieved and morphometric data obtained. Pharmacokinetic analysis revealed lower systemic exposure of the drug in various organs with POLDOX formulation compared to DOXSoln formulation. This was demonstrated by a lower area under the curve (852.1 ± 409.1 ng/mL·h vs 2283.4 ± 377.2 ng/mL·h) in the plasma profile, suggesting a potential reduction in systemic toxicity. Overall, the use of POL formulation offers a promising strategy for precise and localized drug delivery, that may minimize adverse effects. Dual modality POL imaging enabled analysis of patterns of gel distribution and morphology, alongside of pharmacokinetics of local delivery. Incorporating hydrogels into drug delivery systems holds significant promise for improving the predictability of the delivered drug and enhancing spatial conformability. These advancements can potentially enhance the safety and precision of anticancer therapy.

9.
Pediatr Res ; 73(5): 621-9, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23370411

RESUMEN

BACKGROUND: Persistent pulmonary hypertension of the newborn (PPHN) is associated with increased oxidative stress in pulmonary arteries (PAs). Betamethasone decreases the oxidative stress and improves antioxidant balance in PPHN. We investigated whether antenatal betamethasone improves pulmonary vasodilation and postnatal oxygenation in late preterm lambs with PPHN. METHODS: PPHN was induced by constriction of fetal ductus arteriosus from 128 to 136 d gestation. Ewes were given two intramuscular doses of betamethasone or saline at 24 and 12 h before cesarean-section delivery at 136 d gestation, simulating late preterm birth. Newborn lambs were mechanically ventilated for 8 h with monitoring of blood gas and hemodynamic variables. Lungs were harvested postmortem to determine oxidative stress markers and in vitro responses of PAs. RESULTS: Postnatal arterial partial pressure of oxygen and pH were higher and the oxygenation index and arterial partial pressure of carbon dioxide were lower in betamethasone-treated lambs. PA pressure was lower and systemic pressure higher in lambs treated with betamethasone. Betamethasone decreased the oxidative stress markers and increased endothelial nitric oxide synthase expression in ventilated PPHN lungs. CONCLUSION: Antenatal betamethasone decreases oxidative stress and improves postnatal transition in late preterm lambs with PPHN. This study suggests a potential benefit for antenatal betamethasone in late preterm births.


Asunto(s)
Animales Recién Nacidos , Betametasona/uso terapéutico , Glucocorticoides/uso terapéutico , Hipertensión Pulmonar/prevención & control , Animales , Ovinos
10.
J Med Imaging (Bellingham) ; 10(2): 025001, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36875636

RESUMEN

Purpose: An augmented reality (AR) system was developed to facilitate free-hand real-time needle guidance for transperineal prostate (TP) procedures and to overcome the limitations of a traditional guidance grid. Approach: The HoloLens AR system enables the superimposition of annotated anatomy derived from preprocedural volumetric images onto a patient and addresses the most challenging part of free-hand TP procedures by providing real-time needle tip localization and needle depth visualization during insertion. The AR system accuracy, or the image overlay accuracy ( n = 56 ), and needle targeting accuracy ( n = 24 ) were evaluated within a 3D-printed phantom. Three operators each used a planned-path guidance method ( n = 4 ) and free-hand guidance ( n = 4 ) to guide needles into targets in a gel phantom. Placement error was recorded. The feasibility of the system was further evaluated by delivering soft tissue markers into tumors of an anthropomorphic pelvic phantom via the perineum. Results: The image overlay error was 1.29 ± 0.57 mm , and needle targeting error was 2.13 ± 0.52 mm . The planned-path guidance placements showed similar error compared to the free-hand guidance ( 4.14 ± 1.08 mm versus 4.20 ± 1.08 mm , p = 0.90 ). The markers were successfully implanted either into or in close proximity to the target lesion. Conclusions: The HoloLens AR system can provide accurate needle guidance for TP interventions. AR support for free-hand lesion targeting is feasible and may provide more flexibility than grid-based methods, due to the real-time 3D and immersive experience during free-hand TP procedures.

11.
Comp Med ; 2023 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-36914240

RESUMEN

We characterized cryoablation as a mode of clinical intervention in adult woodchucks with hepatocellular carcinoma (HCC). Woodchucks (n = 4) were infected with woodchuck hepatitis virus at birth and developed LI-RADS-5 hypervascular HCC. At 21 mo of age, they underwent ultrasound (US), contrast-enhanced CT (CECT) imaging, and US-guided subtotal cryoablation (IcePearl 2.1 CX, Galil, BTG) of their largest tumor (Mean HCC volume of 49 ± 9 cm³). Cryoablation was performed using two 10-min freeze cycles, each followed by an 8-min thaw cycle. The first woodchuck developed significant hemorrhage after the procedure and was euthanized. In the other 3 woodchucks, the probe track was cauterized and all 3 completed the study. Fourteen days after ablation, CECT was performed, and woodchucks were euthanized. Explanted tumors were sectioned using subject-specific, 3D-printed cutting molds. Initial tumor volume, the size of the cryoablation ice ball, gross pathology and hematoxylin and eosin-stained tissue sections were evaluated. On US, the edges of the solid ice balls were echogenic with dense acoustic shadowing and average dimensions of 3.1 ± 0.5 × 2.1 ± 0.4 cm and cross-sectional area of 4.7 ± 1.0 cm². On day 14 after cryoablation, CECT of the 3 woodchucks showed devascularized hypo-attenuating cryolesions with dimensions of 2.8 ± 0.3 × 2.6 ± 0.4 × 2.93 ± 0.7 cm and a cross sectional area of 5.8 ± 1.2 cm². Histopathologic evaluation showed hemorrhagic necrosis with a central amorphous region of coagulative necrosis surrounded by a rim of karyorrhectic debris. A rim of approximately 2.5 mm of coagulative necrosis and fibrous connective tissue clearly demarcated the cryolesion from adjacent HCC. Partial cryoablation of tumors produced coagulative necrosis with well-defined ablation margins at 14 d. Cauterization appeared to prevent hemorrhage after cryoablation of hypervascular tumors. Our findings indicate that woodchucks with HCC may provide a predictive preclinical model for investigating ablative modalities and developing new combination therapies.

12.
PLoS One ; 18(8): e0289674, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37540658

RESUMEN

PURPOSE: Heat-induced destruction of cancer cells via microwave ablation (MWA) is emerging as a viable treatment of primary and metastatic liver cancer. Prediction of the impacted zone where cell death occurs, especially in the presence of vasculature, is challenging but may be achieved via biophysical modeling. To advance and characterize thermal MWA for focal cancer treatment, an in vivo method and experimental dataset were created for assessment of biophysical models designed to dynamically predict ablation zone parameters, given the delivery device, power, location, and proximity to vessels. MATERIALS AND METHODS: MWA zone size, shape, and temperature were characterized and monitored in the absence of perfusion in ex vivo liver and a tissue-mimicking thermochromic phantom (TMTCP) at two power settings. Temperature was monitored over time using implanted thermocouples with their locations defined by CT. TMTCPs were used to identify the location of the ablation zone relative to the probe. In 6 swine, contrast-enhanced CTs were additionally acquired to visualize vasculature and absence of perfusion along with corresponding post-mortem gross pathology. RESULTS: Bench studies demonstrated average ablation zone sizes of 4.13±1.56cm2 and 8.51±3.92cm2, solidity of 0.96±0.06 and 0.99±0.01, ablations centered 3.75cm and 3.5cm proximal to the probe tip, and temperatures of 50 ºC at 14.5±13.4s and 2.5±2.1s for 40W and 90W ablations, respectively. In vivo imaging showed average volumes of 9.8±4.8cm3 and 33.2±28.4cm3 and 3D solidity of 0.87±0.02 and 0.75±0.15, and gross pathology showed a hemorrhagic halo area of 3.1±1.2cm2 and 9.1±3.0cm2 for 40W and 90W ablations, respectfully. Temperatures reached 50ºC at 19.5±9.2s and 13.0±8.3s for 40W and 90W ablations, respectively. CONCLUSION: MWA results are challenging to predict and are more variable than manufacturer-provided and bench predictions due to vascular stasis, heat-induced tissue changes, and probe operating conditions. Accurate prediction of MWA zones and temperature in vivo requires comprehensive thermal validation sets.


Asunto(s)
Hígado , Animales , Porcinos , Hígado/patología , Hígado/cirugía , Microondas , Temperatura , Técnicas de Ablación , Ablación por Radiofrecuencia
13.
Am J Physiol Lung Cell Mol Physiol ; 303(10): L870-9, 2012 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-22962015

RESUMEN

A rapid increase in the synthesis and release of nitric oxide (NO) facilitates the pulmonary vasodilation that occurs during birth-related transition. Alteration of this transition in persistent pulmonary hypertension of the newborn (PPHN) is associated with impaired function of endothelial nitric oxide synthase (eNOS) and an increase in oxidative stress. We investigated the hypothesis that a decrease in expression and activity of mitochondrial localized manganese superoxide dismutase (MnSOD) in pulmonary artery endothelial cells (PAEC) increases oxidative stress and impairs eNOS function in PPHN. We isolated PAEC and pulmonary arteries from fetal lambs with PPHN induced by prenatal ductus arteriosus ligation or sham ligation (control). We investigated MnSOD expression and activity, tyrosine nitration of MnSOD, and mitochondrial O(2)(-) levels in PAEC from control and PPHN lambs. We introduced exogenous MnSOD via an adenoviral vector (ad-MnSOD) transduction into PAEC and pulmonary arteries of PPHN lambs. The effect of ad-MnSOD was investigated on: mitochondrial O(2)(-) levels, MnSOD and eNOS expression and activity, intracellular hydrogen peroxide (H(2)O(2)) levels, and catalase expression in PAEC. MnSOD mRNA and protein levels and activity were decreased and MnSOD tyrosine nitration was increased in PPHN-PAEC. ad-MnSOD transduction of PPHN-PAEC increased its activity two- to threefold, decreased mitochondrial O(2)(-) levels, and increased H(2)O(2) levels and catalase expression. ad-MnSOD transduction improved eNOS expression and function and the relaxation response of PPHN pulmonary arteries. Our observations suggest that decreased MnSOD expression and activity contribute to the endothelial dysfunction observed in PPHN.


Asunto(s)
Células Endoteliales/enzimología , Regulación Enzimológica de la Expresión Génica , Estrés Oxidativo , Síndrome de Circulación Fetal Persistente/enzimología , Arteria Pulmonar/enzimología , Superóxido Dismutasa/biosíntesis , Adenoviridae , Animales , Modelos Animales de Enfermedad , Células Endoteliales/patología , Vectores Genéticos , Humanos , Peróxido de Hidrógeno/metabolismo , Recién Nacido , Mitocondrias/enzimología , Mitocondrias/genética , Mitocondrias/patología , Óxido Nítrico/biosíntesis , Óxido Nítrico/genética , Óxido Nítrico Sintasa de Tipo III/biosíntesis , Óxido Nítrico Sintasa de Tipo III/genética , Síndrome de Circulación Fetal Persistente/genética , Síndrome de Circulación Fetal Persistente/patología , Síndrome de Circulación Fetal Persistente/fisiopatología , Arteria Pulmonar/patología , Arteria Pulmonar/fisiopatología , ARN Mensajero/biosíntesis , ARN Mensajero/genética , Ovinos , Superóxido Dismutasa/genética , Superóxidos/metabolismo , Transducción Genética , Vasodilatación/genética
14.
Sci Transl Med ; 14(666): eabm8351, 2022 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-36223450

RESUMEN

The COVID-19 pandemic demonstrated the need for inexpensive, easy-to-use, rapidly mass-produced resuscitation devices that could be quickly distributed in areas of critical need. In-line miniature ventilators based on principles of fluidics ventilate patients by automatically oscillating between forced inspiration and assisted expiration as airway pressure changes, requiring only a continuous supply of pressurized oxygen. Here, we designed three miniature ventilator models to operate in specific pressure ranges along a continuum of clinical lung injury (mild, moderate, and severe injury). Three-dimensional (3D)-printed prototype devices evaluated in a lung simulator generated airway pressures, tidal volumes, and minute ventilation within the targeted range for the state of lung disease each was designed to support. In testing in domestic swine before and after induction of pulmonary injury, the ventilators for mild and moderate injury met the design criteria when matched with the appropriate degree of lung injury. Although the ventilator for severe injury provided the specified design pressures, respiratory rate was elevated with reduced minute ventilation, a result of lung compliance below design parameters. Respiratory rate reflected how well each ventilator matched the injury state of the lungs and could guide selection of ventilator models in clinical use. This simple device could help mitigate shortages of conventional ventilators during pandemics and other disasters requiring rapid access to advanced airway management, or in transport applications for hands-free ventilation.


Asunto(s)
Lesión Pulmonar Aguda , COVID-19 , Animales , Homeostasis , Humanos , Oxígeno , Pandemias , Impresión Tridimensional , Frecuencia Respiratoria , Porcinos , Ventiladores Mecánicos
15.
Am J Physiol Lung Cell Mol Physiol ; 301(3): L334-45, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21622842

RESUMEN

Persistent pulmonary hypertension of the newborn (PPHN) is associated with decreased blood vessel density that contributes to increased pulmonary vascular resistance. Previous studies showed that uncoupled endothelial nitric oxide (NO) synthase (eNOS) activity and increased NADPH oxidase activity resulted in marked decreases in NO bioavailability and impaired angiogenesis in PPHN. In the present study, we hypothesize that loss of tetrahydrobiopterin (BH4), a critical cofactor for eNOS, induces uncoupled eNOS activity and impairs angiogenesis in PPHN. Pulmonary artery endothelial cells (PAEC) isolated from fetal lambs with PPHN (HTFL-PAEC) or control lambs (NFL-PAEC) were used to investigate the cellular mechanisms impairing angiogenesis in PPHN. Cellular mechanisms were examined with respect to BH4 levels, GTP-cyclohydrolase-1 (GCH-1) expression, eNOS dimer formation, and eNOS-heat shock protein 90 (hsp90) interactions under basal conditions and after sepiapterin (Sep) supplementation. Cellular levels of BH4, GCH-1 expression, and eNOS dimer formation were decreased in HTFL-PAEC compared with NFL-PAEC. Sep supplementation decreased apoptosis and increased in vitro angiogenesis in HTFL-PAEC and ex vivo pulmonary artery sprouting angiogenesis. Sep also increased cellular BH4 content, NO production, eNOS dimer formation, and eNOS-hsp90 association and decreased the superoxide formation in HTFL-PAEC. These data demonstrate that Sep improves NO production and angiogenic potential of HTFL-PAEC by recoupling eNOS activity. Increasing BH4 levels via Sep supplementation may be an important therapy for improving eNOS function and restoring angiogenesis in PPHN.


Asunto(s)
Óxido Nítrico Sintasa de Tipo III/metabolismo , Pterinas/farmacología , Animales , Apoptosis/efectos de los fármacos , Biopterinas/análogos & derivados , Biopterinas/metabolismo , Movimiento Celular/efectos de los fármacos , Endotelio Vascular/metabolismo , GTP Ciclohidrolasa/biosíntesis , Proteínas HSP90 de Choque Térmico/metabolismo , Humanos , Recién Nacido , Neovascularización Fisiológica/efectos de los fármacos , Óxido Nítrico Sintasa de Tipo III/efectos de los fármacos , Síndrome de Circulación Fetal Persistente , Multimerización de Proteína/efectos de los fármacos , Oveja Doméstica
16.
J Hepatocell Carcinoma ; 8: 71-83, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33728278

RESUMEN

BACKGROUND: Woodchucks chronically infected with woodchuck hepatitis virus (WHV), which resembles human hepatitis B virus, develop spontaneous hepatic tumors and may be an important biological and immunological model for human HCC. Nonetheless, this model requires further validation to fully realize its translational potential. METHODS: Woodchucks infected at birth with WHV that had developed HCC (n=12) were studied. Computed tomography, ultrasound, and magnetic resonance imaging were performed under anesthesia. LI-RADS scoring and correlative histologic analysis of sectioned tissues were performed. For immune characterization of tumors, CD3 (T cells), CD4 (T helpers), NCAM (Natural killers), FOXP3 (T-regulatory), PDL-1 (inhibitory checkpoint protein), and the human hepatocellular carcinoma (HCC) biomarker alpha-fetoprotein (AFP) immunohistochemical stains were performed. RESULTS: Forty tumors were identified on imaging of which 29 were confirmed to be HCC with 26 categorized as LR-4 or 5. The remainder of the tumors had benign histology including basophilic foci, adenoma, and lipidosis as well as pre-malignant dysplastic foci. LR-4 and LR-5 lesions showed high sensitivity (90%) and specificity (100%) for malignant and pre-malignant tumors. Natural killers count was found to be 2-5 times lower in tumors relative to normal parenchyma while other immune cells were located in the periphery of tumors. Tumors expressed AFP and did not express PD-L1. CONCLUSION: Woodchucks chronically infected with WHV developed diverse hepatic tumor types with diagnostic imaging, pathology, and immune patterns comparable to that in humans. This unique animal model may provide a valuable tool for translation and validation of novel image-guided and immune-therapeutic investigations.

17.
Cardiovasc Intervent Radiol ; 44(9): 1439-1447, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34021380

RESUMEN

PURPOSE: To evaluate an integrated liver biopsy platform that combined CT image fusion, electromagnetic (EM) tracking, and optical molecular imaging (OMI) of indocyanine green (ICG) to target hepatocellular carcinoma (HCC) lesions and a point-of-care (POC) OMI to assess biopsy cores, all based on tumor retention of ICG compared to normal liver, in phantom and animal model. MATERIAL: A custom CT image fusion and EM-tracked guidance platform was modified to integrate the measurement of ICG fluorescence intensity signals in targeted liver tissue with an OMI stylet or a POC OMI system. Accuracy was evaluated in phantom and a woodchuck with HCC, 1 day after administration of ICG. Fresh biopsy cores and paraffin-embedded formalin-fixed liver tissue blocks were evaluated with the OMI stylet or POC system to identify ICG fluorescence signal and ICG peak intensity. RESULTS: The mean distance between the initial guided needle delivery location and the peak ICG signal was 5.0 ± 4.7 mm in the phantom. There was complete agreement between the reviewers of the POC-acquired ICG images, cytology, and histopathology in differentiating HCC-positive from HCC-negative biopsy cores. The peak ICG fluorescence intensity signal in the ex vivo liver blocks was 39 ± 12 and 281 ± 150 for HCC negative and HCC positive, respectively. CONCLUSION: Biopsy guidance with fused CT imaging, EM tracking, and ICG tracking with an OMI stylet to detect HCC is feasible. Immediate assessment of ICG uptake in biopsy cores with the POC OMI system is feasible and correlates with the presence of HCC in the tissue.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Animales , Biopsia , Carcinoma Hepatocelular/diagnóstico por imagen , Modelos Animales de Enfermedad , Fenómenos Electromagnéticos , Neoplasias Hepáticas/diagnóstico por imagen , Marmota , Imagen Molecular , Sistemas de Atención de Punto
18.
Transl Lung Cancer Res ; 10(8): 3627-3644, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34584862

RESUMEN

BACKGROUND: Endobronchial navigation is performed in a variety of ways, none of which are meeting all the clinicians' needs required to reach diagnostic success in every patient. We sought to characterize precurved and steerable guiding sheaths (GS) in endobronchial targeting for lung biopsy using cone beam computed tomography (CBCT) based augmented fluoroscopy (AF) image guidance. METHODS: Four precurved GS (EdgeTM 45, 90, 180, 180EW, Medtronic) and two steerable GS [6.5 F Destino Twist (DT), Oscor; 6 F Morph, BioCardia] were evaluated alone and in combination with an electromagnetic tracking (EM) guide and biopsy needles in three experimental phases: (I) bench model to assess GS deflection and perform biopsy simulations; (II) ex vivo swine lung comparing 2 steerable and 2 precurved GS; and (III) in vivo male swine lung to deliver a needle (n=2 swine) or to deliver a fiducial marker (n=2 swine) using 2 steerable GS. Ex vivo and in vivo image guidance was performed with either commercial or prototype AF image guidance software (Philips) based on either prior CT or procedural CBCT. Primary outcomes were GS delivery angle (θGS) and needle delivery angle (θN) in bench evaluation and needle delivery error (mm) (mean ± se) for ex vivo and in vivo studies. RESULTS: The steerable DT had the largest range of GS delivery angles (θN: 0-114°) with either the 21 G or 19 G biopsy needle in the bench model. In ex vivo swine lung, needle delivery errors were 8.7±0.9 mm (precurved Edge 90), 5.4±1.9 mm (precurved Edge 180), 4.7±1.2 mm (steerable DT), and 5.6±2.4 mm (steerable Morph). In vivo, the needle delivery errors for the steerable GS were 6.0±1.0 mm (DT) and 15±7.0 mm (Morph). In vivo marker coil delivery was successful for both the steerable DT and morph GS. A case report demonstrated successful needle biopsy with the steerable DT. CONCLUSIONS: Endobronchial needle delivery with AF guidance is feasible without a bronchoscope with steerable GS providing comparable or improved accuracy compared to precurved GS.

19.
Eur Radiol Exp ; 4(1): 24, 2020 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-32300896

RESUMEN

BACKGROUND: Uncorrected patient or prostate motion may impair targeting prostate areas during fusion image-guided procedures. We evaluated if a prototype "tracked Foley catheter" (TFC) could maintain fusion image alignment after simulated organ motion. METHODS: A pelvic phantom model underwent magnetic resonance imaging (MRI), and the prostate was segmented. The TFC was placed in the phantom. MRI/ultrasound (US) fusion was performed. Four trials were performed varying motion and TFC presence/absence: (1) TFC/no-motion, (2) TFC/motion, (3) no-TFC/no-motion, and (4) no-TFC/motion. To quantify image alignment, screen captures generated Dice similarity coefficient (DSC) and offset distances (ODs) (maximal US-to-MRI distance between edges on fusion images). Three anatomical targets were identified for placement of a needle under fusion guidance. A computed tomography scan was used to measure system error (SE), i.e., the distance from needle tip to intended target. RESULTS: The TFC presence improved MRI/US alignment by DSC 0.88, 0.88, 0.74, and 0.61 in trials 1, 2, 3, and 4, respectively. Both OD (trial 2 versus trial 4, 4.85 ± 1.60 versus 25.29 ± 6.50 mm, p < 0.001) and SE (trial 2 versus trial 4, 6.35 ± 1.31 versus 32.16 ± 6.50 mm, p < 0.005) were significantly lower when the TFC was present after artificial motion, and significantly smaller OD when static (trial 1 versus trial 3, 4.29 ± 1.24 versus 6.42 ± 2.29 mm, p < 0.001). CONCLUSION: TFC provided better image alignment with or without simulated motion. This may overcome system limitations, allowing for more accurate fusion image alignment during fusion-guided biopsy, ablation, or robotic prostatectomy.


Asunto(s)
Catéteres , Imagen Multimodal , Próstata/diagnóstico por imagen , Ablación por Catéter , Humanos , Aumento de la Imagen , Interpretación de Imagen Asistida por Computador , Biopsia Guiada por Imagen , Imagen por Resonancia Magnética , Masculino , Movimiento (Física) , Fantasmas de Imagen , Prostatectomía , Procedimientos Quirúrgicos Robotizados , Ultrasonografía
20.
Cardiovasc Intervent Radiol ; 43(12): 1918-1924, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32803282

RESUMEN

PURPOSE: Topotecan is a camptothecin analogue with potential advantages over irinotecan for transarterial chemoembolization (TACE) of hepatic colorectal metastases including greater anti-neoplastic activity without enzymatic activation. The purpose of this study was to assess safety and tolerability of topotecan-loaded radiopaque microspheres (ROMTOP) administered by TACE in a rabbit model and to compare the in vitro elution of topotecan from microspheres to irinotecan. MATERIALS AND METHODS: Topotecan was loaded into radiopaque microspheres (70-150 µm, DC Bead LUMI™, Biocompatibles UK Ltd-Boston Scientific Corporation) to the maximum capacity of 80 mg/mL of microspheres. Six healthy New Zealand White rabbits underwent hepatic TACE with ROMTOP under fluoroscopic guidance until angiographic stasis. Assessment of toxicities included regular liver function tests and complete blood counts until euthanasia 28 days post-TACE. In vitro topotecan elution from the microspheres was assessed using an open-loop flow-through system and compared to irinotecan. RESULTS: The mean bead volume and topotecan dose delivered were 0.086 mL (0.076-0.105 mL) and 1.99 mg/kg (1.51-2.55 mg/kg), respectively. Aspartate aminotransferase and alanine aminotransferase were elevated post-embolization but resolved within 2 weeks. One rabbit died two days after TACE with pyloric duodenal perforation observed at necropsy, potentially due to non-target embolization. In vitro elution of topotecan from ROMTOP was complete in 10 h compared to 3 h for irinotecan-loaded microspheres. CONCLUSION: Selective embolization with ROMTOP was tolerated at a dose of 2 mg/kg (24 mg/m2) in rabbits. In vitro topotecan elution from microspheres was more prolonged compared to irinotecan.


Asunto(s)
Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Neoplasias Hepáticas Experimentales/terapia , Topotecan/farmacología , Animales , Carcinoma Hepatocelular/diagnóstico , Humanos , Irinotecán , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas Experimentales/diagnóstico , Microesferas , Conejos , Inhibidores de Topoisomerasa I/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA