RESUMEN
BACKGROUND: We introduced a probabilistic treatment planning approach that prospectively incorporates respiratory-induced motion in the treatment plan optimization. The aim of this study was to determine the potential dosimetric benefit by comparing this approach to the use of an internal target volume (ITV). MATERIAL AND METHOD: We retrospectively compared the probabilistic respiratory motion-incorporated (RMI) approach to the ITV approach for 18 pancreatic cancer patients, for seven simulated respiratory amplitudes from 5 to 50 mm in the superior-inferior (SI) direction. For each plan, we assessed the target coverage (required: D98%≥95% of 50 Gy prescribed dose). For the RMI plans, we investigated whether target coverage was robust against daily variations in respiratory amplitude. We determined the distance between the clinical target volume and the 30 Gy isodose line (i.e. dose gradient steepness) in the SI direction. To investigate the clinical benefit of the RMI approach, we created for each patient an ITV and RMI treatment plan for the three-dimensional (3D) respiratory amplitudes observed on their pretreatment 4D computed tomography (4DCT). We determined Dmean, V30Gy, V40Gy and V50Gy for the duodenum. RESULTS: All treatment plans yielded good target coverage. The RMI plans were robust against respiratory amplitude variations up to 10 mm, as D98% remained ≥95%. We observed steeper dose gradients compared to the ITV approach, with a mean decrease from 25.9 to 19.2 mm for a motion amplitude of 50 mm. For the 4DCT motion amplitudes, the RMI approach resulted in a mean decrease of 0.43 Gy, 1.1 cm3, 1.4 cm3 and 0.9 cm3 for the Dmean, V30Gy, V40Gy and V50Gy of the duodenum, respectively. CONCLUSION: The probabilistic treatment planning approach yielded significantly steeper dose gradients and therefore significantly lower dose to surrounding healthy tissues than the ITV approach. However, the observed dosimetric gain for clinically observed respiratory motion amplitudes for this patient group was limited.
Asunto(s)
Movimiento (Física) , Neoplasias Pancreáticas/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Respiración , Técnicas de Imagen Sincronizada Respiratorias/métodos , Humanos , Neoplasias Pancreáticas/patología , Probabilidad , Radiometría , Dosificación Radioterapéutica , Estudios RetrospectivosRESUMEN
ABSTRACT: The leukemic stem cell (LSC) score LSC-17 based on a stemness-related gene expression signature is an indicator of poor disease outcome in acute myeloid leukemia (AML). However, it is not known whether "niche anchoring" of LSC affects disease evolution. To address this issue, we conditionally inactivated the adhesion molecule JAM-C (Junctional Adhesion Molecule-C) expressed by hematopoietic stem cells (HSCs) and LSCs in an inducible mixed-lineage leukemia (iMLL)-AF9-driven AML mouse model. Deletion of Jam3 (encoding JAM-C) before induction of the leukemia-initiating iMLL-AF9 fusion resulted in a shift from long-term to short-term HSC expansion, without affecting disease initiation and progression. In vitro experiments showed that JAM-C controlled leukemic cell nesting irrespective of the bone marrow stromal cells used. RNA sequencing performed on leukemic HSCs isolated from diseased mice revealed that genes upregulated in Jam3-deficient animals belonged to activation protein-1 (AP-1) and tumor necrosis factor α (TNF-α)/NF-κB pathways. Human orthologs of dysregulated genes allowed to identify a score that was distinct from, and complementary to, the LSC-17 score. Substratification of patients with AML using LSC-17 and AP-1/TNF-α genes signature defined 4 groups with median survival ranging from <1 year to a median of "not reached" after 8 years. Finally, coculture experiments showed that AP-1 activation in leukemic cells was dependent on the nature of stromal cells. Altogether, our results identify the AP-1/TNF-α gene signature as a proxy of LSC anchoring in bone marrow niches, which improves the prognostic value of the LSC-17 score. This trial was registered at www.ClinicalTrials.gov as #NCT02320656.
Asunto(s)
Moléculas de Adhesión Celular , Regulación Leucémica de la Expresión Génica , Leucemia Mieloide Aguda , Células Madre Neoplásicas , Animales , Humanos , Ratones , Moléculas de Adhesión Celular/metabolismo , Moléculas de Adhesión Celular/genética , Modelos Animales de Enfermedad , Eliminación de Gen , Células Madre Hematopoyéticas/metabolismo , Inmunoglobulinas , Leucemia Mieloide Aguda/genética , Leucemia Mieloide Aguda/metabolismo , Leucemia Mieloide Aguda/patología , Células Madre Neoplásicas/metabolismo , Células Madre Neoplásicas/patología , Estudios LongitudinalesRESUMEN
PURPOSE: The primary objective of this prospective pilot trial was to assess the safety and feasibility of lung functional avoidance radiation therapy (RT) with 4-dimensional (4D) computed tomography (CT) ventilation imaging. METHODS AND MATERIALS: Patients with primary lung cancer or metastatic disease to the lungs to receive conventionally fractionated RT (CFRT) or stereotactic body RT (SBRT) were eligible. Standard-of-care 4D-CT scans were used to generate ventilation images through image processing/analysis. Each patient required a standard intensity modulated RT plan and ventilation image guided functional avoidance plan. The primary endpoint was the safety of functional avoidance RT, defined as the rate of grade ≥3 adverse events (AEs) that occurred ≤12 months after treatment. Protocol treatment was considered safe if the rates of grade ≥3 pneumonitis and esophagitis were <13% and <21%, respectively for CFRT, and if the rate of any grade ≥3 AEs was <28% for SBRT. Feasibility of functional avoidance RT was assessed by comparison of dose metrics between the 2 plans using the Wilcoxon signed-rank test. RESULTS: Between May 2015 and November 2019, 34 patients with non-small cell lung cancer were enrolled, and 33 patients were evaluable (n = 24 for CFRT; n = 9 for SBRT). Median follow-up was 14.7 months. For CFRT, the rates of grade ≥3 pneumonitis and esophagitis were 4.2% (95% confidence interval, 0.1%-21.1%) and 12.5% (2.7%-32.4%). For SBRT, no patients developed grade ≥3 AEs. Compared with the standard plans, the functional avoidance plans significantly (P < .01) reduced the lung dose-function metrics without compromising target coverage or adherence to standard organs at risk constraints. CONCLUSIONS: This study, representing one of the first prospective investigations on lung functional avoidance RT, demonstrated that the 4D-CT ventilation image guided functional avoidance RT that significantly reduced dose to ventilated lung regions could be safely administered, adding to the growing body of evidence for its clinical utility.
Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Carcinoma de Pulmón de Células no Pequeñas/patología , Tomografía Computarizada Cuatridimensional/métodos , Pulmón/patología , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patología , Estudios Prospectivos , Planificación de la Radioterapia Asistida por Computador/métodosRESUMEN
This paper systematically evaluates a pharmacokinetic compartmental model for identifying tumor hypoxia using dynamic positron emission tomography (PET) imaging with 18F-fluoromisonidazole (FMISO). A generic irreversible one-plasma two-tissue compartmental model was used. A dynamic PET image dataset was simulated with three tumor regions-normoxic, hypoxic and necrotic-embedded in a normal-tissue background, and with an image-based arterial input function. Each voxelized tissue's time activity curve (TAC) was simulated with typical values of kinetic parameters, as deduced from FMISO-PET data from nine head-and-neck cancer patients. The dynamic dataset was first produced without any statistical noise to ensure that correct kinetic parameters were reproducible. Next, to investigate the stability of kinetic parameter estimation in the presence of noise, 1000 noisy samples of the dynamic dataset were generated, from which 1000 noisy estimates of kinetic parameters were calculated and used to estimate the sample mean and covariance matrix. It is found that a more peaked input function gave less variation in various kinetic parameters, and the variation of kinetic parameters could also be reduced by two region-of-interest averaging techniques. To further investigate how bias in the arterial input function affected the kinetic parameter estimation, a shift error was introduced in the peak amplitude and peak location of the input TAC, and the bias of various kinetic parameters calculated. In summary, mathematical phantom studies have been used to determine the statistical accuracy and precision of model-based kinetic analysis, which helps to validate this analysis and provides guidance in planning clinical dynamic FMISO-PET studies.
Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Misonidazol/análogos & derivados , Modelos Biológicos , Neoplasias/metabolismo , Consumo de Oxígeno , Oxígeno/metabolismo , Tomografía de Emisión de Positrones/métodos , Algoritmos , Simulación por Computador , Humanos , Aumento de la Imagen/métodos , Misonidazol/farmacocinética , Neoplasias/diagnóstico por imagen , Oxígeno/análisis , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
PURPOSE: Lung functional image guided radiation therapy (RT) that avoids irradiating highly functional regions has potential to reduce pulmonary toxicity following RT. Tumor regression during RT is common, leading to recovery of lung function. We hypothesized that computed tomography (CT) ventilation image-guided treatment planning reduces the functional lung dose compared to standard anatomic image-guided planning in 2 different scenarios with or without plan adaptation. METHODS AND MATERIALS: CT scans were acquired before RT and during RT at 2 time points (16-20 Gy and 30-34 Gy) for 14 patients with locally advanced lung cancer. Ventilation images were calculated by deformable image registration of four-dimensional CT image data sets and image analysis. We created 4 treatment plans at each time point for each patient: functional adapted, anatomic adapted, functional unadapted, and anatomic unadapted plans. Adaptation was performed at 2 time points. Deformable image registration was used for accumulating dose and calculating a composite of dose-weighted ventilation used to quantify the lung accumulated dose-function metrics. The functional plans were compared with the anatomic plans for each scenario separately to investigate the hypothesis at a significance level of 0.05. RESULTS: Tumor volume was significantly reduced by 20% after 16 to 20 Gy (P = .02) and by 32% after 30 to 34 Gy (P < .01) on average. In both scenarios, the lung accumulated dose-function metrics were significantly lower in the functional plans than in the anatomic plans without compromising target volume coverage and adherence to constraints to critical structures. For example, functional planning significantly reduced the functional mean lung dose by 5.0% (P < .01) compared to anatomic planning in the adapted scenario and by 3.6% (P = .03) in the unadapted scenario. CONCLUSIONS: This study demonstrated significant reductions in the accumulated dose to the functional lung with CT ventilation image-guided planning compared to anatomic image-guided planning for patients showing tumor regression and changes in regional ventilation during RT.
Asunto(s)
Neoplasias Pulmonares/radioterapia , Pulmón/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Pulmón/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ventilación Pulmonar , Dosificación Radioterapéutica , Carga TumoralRESUMEN
BACKGROUND AND PURPOSES: To quantify the cold or hot spot induced in IMRT treatment plans due to the presence of metal artifact in CT image data sets stemming from dental work. PATIENTS AND METHODS: Metal artifact corrected image data sets of five patients have been analyzed. IMRT plans were generated using five different planning image data sets: (a) uncorrected (UC) (b) homogeneous uncorrected (HUC), (c) sinogram completion corrected (SCC), (d) minimum value corrected (MVC), and (e) image set (d) subsequently corrected with a streak artifacts reduction algorithm (SAR-MVC). The SAR-MVC data set is assumed to be the closest approximation to the absence of metal artifacts and has therefore been taken as the reference image data set. An IMRT plan was generated for each of the image datasets (a)-(e). The resulting IMRT treatment plans for data sets (a)-(d) were then projected onto the reference data set (e) and recalculated. The reference dose distribution (e) was then subtracted from these recalculated dose distributions. Using dose difference analysis, the cold and hot spots in organs at risk (OARs) and the target volumes (TVs) were quantified. RESULTS: When compared to the reference dose distribution, the UC, HUC, and SCC plans exhibited hot spots showing on average more than 1.0 Gy hot dose in the left and right parotids. For the UC, HUC, and SCC recalculated plans, subvolumes of the clinical target volumes (CTV) were under dosed on average by more than 0.9 Gy. On the other hand, the MVC plan showed less than 0.3 Gy hot dose in both parotids, and the cold dose in the CTVs were reduced by up to 0.8 Gy. CONCLUSIONS: The presence of dental metal artifacts in head and neck planning CT data sets can lead to relative hot spots in OARs and relative cold spots in regions of the TVs when compared to the reference data set that more closely approximates the patient anatomy. This effect can be reduced if a simple minimum value correction (MVC) method for the dental metal artifacts is employed.
Asunto(s)
Artefactos , Materiales Dentales , Neoplasias de Cabeza y Cuello/radioterapia , Radioterapia de Intensidad Modulada , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Dosificación Radioterapéutica/normas , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos XRESUMEN
High-density objects such as metal prostheses, surgical clips, or dental fillings generate streak-like artifacts in computed tomography images. We present a novel method for metal artifact reduction by in-painting missing information into the corrupted sinogram. The information is provided by a tissue-class model extracted from the distorted image. To this end the image is first adaptively filtered to reduce the noise content and to smooth out streak artifacts. Consecutively, the image is segmented into different material classes using a clustering algorithm. The corrupted and missing information in the original sinogram is completed using the forward projected information from the tissue-class model. The performance of the correction method is assessed on phantom images. Clinical images featuring a broad spectrum of metal artifacts are studied. Phantom and clinical studies show that metal artifacts, such as streaks, are significantly reduced and shadows in the image are eliminated. Furthermore, the novel approach improves detectability of organ contours. This can be of great relevance, for instance, in radiation therapy planning, where images affected by metal artifacts may lead to suboptimal treatment plans.
Asunto(s)
Algoritmos , Artefactos , Inteligencia Artificial , Análisis por Conglomerados , Reconocimiento de Normas Patrones Automatizadas/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Imagenología Tridimensional/métodos , Almacenamiento y Recuperación de la Información/métodos , Prótesis e Implantes , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de SustracciónRESUMEN
BACKGROUND AND PURPOSE: Radiotherapy that selectively avoids irradiating highly-functional lung regions may reduce pulmonary toxicity. We report on the first clinical implementation and patient treatment of lung functional image-guided radiotherapy using an emerging technology, computed tomography (CT) ventilation imaging. MATERIAL AND METHODS: A protocol was developed to investigate the safety and feasibility of CT ventilation functional image-guided radiotherapy. CT ventilation imaging is based on (1) deformable image registration of four-dimensional (4D) CT images, and (2) quantitative image analysis for regional volume change, a surrogate for ventilation. CT ventilation functional image-guided radiotherapy plans were designed to minimize specific lung dose-function metrics, including functional V20 (fV20), while maintaining target coverage and meeting standard constraints to other critical organs. RESULTS: CT ventilation functional image-guided treatment planning reduced the lung fV20 by 5% compared to an anatomic image-guided plan for an enrolled patient with stage IIIB non-small cell lung cancer. Although the doses to several other critical organs increased, the necessary constraints were all met. CONCLUSIONS: An emerging technology, CT ventilation imaging has been translated into the clinic and used in functional image-guided radiotherapy for the first time. This milestone represents an important first step toward hypothetically reduced pulmonary toxicity in lung cancer radiotherapy.
Asunto(s)
Tomografía Computarizada Cuatridimensional/métodos , Neoplasias Pulmonares/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Estudios de Factibilidad , Humanos , Pulmón/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Estudios Prospectivos , Traumatismos por Radiación/prevención & controlRESUMEN
PURPOSE: To investigate the hypothesis that CT ventilation functional image-based IMRT plans designed to avoid irradiating highly-functional lung regions are comparable to single-photon emission CT (SPECT) ventilation functional image-based plans. METHODS AND MATERIALS: Three IMRT plans were created for eight thoracic cancer patients using: (1) CT ventilation functional images, (2) SPECT ventilation functional images, and (3) anatomic images (no functional images). CT ventilation images were created by deformable image registration of 4D-CT image data sets and quantitative analysis. The resulting plans were analyzed for the relationship between the deviations of CT-functional plan metrics from anatomic plan metrics (ΔCT-anatomic) and those of SPECT-functional plans (ΔSPECT-anatomic), and moreover for agreements of various metrics between the CT-functional and SPECT-functional plans. RESULTS: The relationship between ΔCT-anatomic and ΔSPECT-anatomic was strong (e.g., R=0.94; linear regression slope 0.71). The average differences and 95% limits of agreement between the CT-functional and SPECT-functional plan metrics (except for monitor units) for various structures were mostly less than 1% and 2%, respectively. CONCLUSIONS: This study demonstrated a reasonable agreement between the CT ventilation functional image-based IMRT plans and SPECT-functional plans, suggesting the potential for CT ventilation imaging to serve as a surrogate for SPECT ventilation in functional image-guided radiotherapy.
Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/radioterapia , Pulmón/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Femenino , Tomografía Computarizada Cuatridimensional/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Radioterapia Guiada por Imagen , Respiración , Tomografía Computarizada de Emisión de Fotón Único/métodosRESUMEN
PURPOSE: To increase local control and decrease side effects for urinary bladder cancer patients by integrating a library planning procedure with image guidance using lipiodol markers. METHODS AND MATERIALS: Twenty patients with T2-T4N0M0 grade 2-3 invasive bladder carcinoma were treated according to an online adaptive protocol. Initially, the gross tumour volume (GTV) was demarcated during cystoscopy by injecting several drops of lipiodol in the submucosa around the tumour. Subsequently two CT scans were acquired with a full bladder and a voided bladder. On both scans, the boost volume (GTV) and the low-risk bladder volume were delineated. Using an interpolation tool, six concomitant boost IMRT plans with increasing bladder volumes were generated. For each fraction the procedure at the treatment unit was as follows: Firstly, a ConeBeam-CT was acquired and based on the amount of bladder filling the best fitting bladder contours and corresponding GTV and IMRT plans were selected. Secondly, the lipiodol markers were registered using the corresponding GTV contours and it was verified that the corresponding 95%-isodose surface covered the entire bladder. Finally, an online setup correction was applied based on this registration and the corresponding treatment plan was irradiated. RESULTS: The lipiodol markers were very useful in outlining the GTV at the planning CT and for daily setup correction. While the patients strived for a full bladder filling at time of the treatment, this was seldom accomplished. Due to our protocol an appropriate plan with adequate coverage of the PTV and without excessive dose to healthy tissue was delivered every day. The treatment was very well tolerated by all patients. At the end of the treatment no grade 3 urinary or gastro-intestinal toxicity was observed. After a median follow-up of 28 months two local relapses occurred. CONCLUSION: Using the library planning approach combined with online image guidance using lipiodol markers, we were able to deliver a highly conformal dose distribution to all bladder cancer patients achieving promising clinical results.
Asunto(s)
Medios de Contraste , Aceite Etiodizado , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Neoplasias de la Vejiga Urinaria/radioterapia , Anciano , Anciano de 80 o más Años , Tomografía Computarizada de Haz Cónico , Humanos , Masculino , Estudios Prospectivos , Tomografía Computarizada por Rayos X , Carga Tumoral , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen , Neoplasias de la Vejiga Urinaria/patologíaRESUMEN
PURPOSE: Local recurrence rates are high in patients with locally advanced NSCLC treated with 60 to 66 Gy in 2 Gy fractions. It is hypothesised that boosting volumes with high SUV on the pre-treatment FDG-PET scan potentially increases local control while maintaining acceptable toxicity levels. We compared two approaches: threshold-based dose painting by contours (DPBC) with voxel-based dose painting by numbers (DPBN). MATERIALS AND METHODS: Two dose painted plans were generated for 10 stage II/III NSCLC patients with 66 Gy at 2-Gy fractions to the entire PTV and a boost dose to the high SUV areas within the primary GTV. DPBC aims for a uniform boost dose at the volume encompassing the SUV 50%-region (GTV(boost)). DPBN aims for a linear relationship between the boost dose to a voxel and the underlying SUV. For both approaches the boost dose was escalated up to 130 Gy (in 33 fractions) or until the dose limiting constraint of an organ at risk was met. RESULTS: For three patients (with relatively small peripheral tumours) the dose within the GTV could be boosted to 130 Gy using both strategies. For the remaining patients the boost dose was confined by a critical structure (mediastinal structures in six patients, lungs in one patient). In general the amount of large brush DPBC boosting is limited whenever the GTV(boost) is close to any serial risk organ. In contrast, small brush DPBN inherently boosts at a voxel-by-voxel basis allowing significant higher dose values to high SUV voxels more distant from the organs at risk. We found that the biological SUV gradients are reasonably congruent with the dose gradients that standard linear accelerators can deliver. CONCLUSIONS: Both large brush DPBC and sharp brush DPBN techniques can be used to considerably boost the dose to the FDG avid regions. However, significantly higher boost levels can be obtained using sharp brush DPBN although sometimes at the cost of a less increased dose to the low SUV regions.
Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Tomografía de Emisión de Positrones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Plexo Braquial/efectos de la radiación , Fraccionamiento de la Dosis de Radiación , Relación Dosis-Respuesta en la Radiación , Esófago/efectos de la radiación , Fluorodesoxiglucosa F18 , Corazón/efectos de la radiación , Humanos , Pulmón/efectos de la radiación , Neoplasias Pulmonares/patología , Metástasis Linfática , Radiometría/métodos , Radiofármacos , Dosificación Radioterapéutica , Médula Espinal/efectos de la radiación , Resultado del TratamientoRESUMEN
Extreme ultraviolet (EUV) lithography uses reflective ring-field projection systems. Geometrical obstruction limits the possible system configurations to small domains of the parameter space. We present an analysis, a search method, and a classification of these unobstructed domains. The exhaustive search method based on paraxial analysis provides an effective means for determining all possible design forms and for finding useful starting configurations for optimization. The approach is validated through comparison with finite ray tracing.
RESUMEN
In this theoretical study we show that by removing or depositing additional multilayer (ML) periods of a thin-film interference coating, distortions in the reflected wave front induced by surface figure errors can be corrected. At lambda = 13.4 nm in the extreme-ultraviolet region the removal or deposition of a single period of the standard two-component molybdenum-silicon (Mo/Si) ML interference coating induces an effective phase change of magnitude 0.043pi with respect to an identical optical thickness in vacuum. The magnitude of this wave-front shift can be enhanced with multicomponent MLs optimized for phase change on reflection. We briefly discuss the contributions of the shift in the effective reflection surface of the ML on the phase change. We also predict the feasibility of novel phase-shifting mask for subwavelength imaging applications.