Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 206
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 92(3): 890-899, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38469953

RESUMEN

PURPOSE: To investigate the feasibility of downfield MR spectroscopic imaging (DF-MRSI) in the human brain at 7T. METHODS: A 7T DF-MRSI pulse sequence was implemented based on the previously described methodology at 3T, with 3D phase-encoding, 1 3 ‾ 3 1 ‾ $$ 1\overline{3}3\overline{1} $$ spectral-spatial excitation, and frequency selective refocusing. Data were pre-processed followed by analysis using the "LCModel" software package, and metabolite maps created from the LCModel results. Total scan time, including brain MRI and a water-reference MRSI, was 24 min. The sequence was tested in 10 normal volunteers. Estimated metabolite levels and uncertainty values (Cramer Rao lower bounds, CRLBs) for nine downfield peaks were compared between seven different brain regions, anterior cingulate cortex (ACC), centrum semiovale (CSO), corpus callosum (CC), cerebellar vermis (CV), dorsolateral prefrontal cortex (DLPFC), posterior cingulate cortex (PCC), and thalamus (Thal). RESULTS: DF peaks were relatively uniformly distributed throughout the brain, with only a small number of peaks showing any significant regional variations. Most DF peaks had average CRLB<25% in most brain regions. Average SNR values were higher for the brain regions ACC and DLPFC (˜7 ± 0.95, mean ± SD) while in a range of 3.4-6.0 for other brain regions. Average linewidth (FWHM) values were greater than 35 Hz in the ACC, CV, and Thal, and 22 Hz in CC, CSO, DLPFC, and PCC. CONCLUSION: High-field DF-MRSI is able to spatially map exchangeable protons in the human brain at high resolution and with near whole-brain coverage in acceptable scan times, and in the future may be used to study metabolism of brain tumors or other neuropathological disorders.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Humanos , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Adulto , Masculino , Femenino , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Voluntarios Sanos , Algoritmos , Programas Informáticos , Adulto Joven
2.
Mol Psychiatry ; 28(5): 2018-2029, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36732587

RESUMEN

Seven Tesla magnetic resonance spectroscopy (7T MRS) offers a precise measurement of metabolic levels in the human brain via a non-invasive approach. Studying longitudinal changes in brain metabolites could help evaluate the characteristics of disease over time. This approach may also shed light on how the age of study participants and duration of illness may influence these metabolites. This study used 7T MRS to investigate longitudinal patterns of brain metabolites in young adulthood in both healthy controls and patients. A four-year longitudinal cohort with 38 patients with first episode psychosis (onset within 2 years) and 48 healthy controls was used to examine 10 brain metabolites in 5 brain regions associated with the pathophysiology of psychosis in a comprehensive manner. Both patients and controls were found to have significant longitudinal reductions in glutamate in the anterior cingulate cortex (ACC). Only patients were found to have a significant decrease over time in γ-aminobutyric acid, N-acetyl aspartate, myo-inositol, total choline, and total creatine in the ACC. Together we highlight the ACC with dynamic changes in several metabolites in early-stage psychosis, in contrast to the other 4 brain regions that also are known to play roles in psychosis. Meanwhile, glutathione was uniquely found to have a near zero annual percentage change in both patients and controls in all 5 brain regions during a four-year follow-up in young adulthood. Given that a reduction of the glutathione in the ACC has been reported as a feature of treatment-refractory psychosis, this observation further supports the potential of glutathione as a biomarker for this subset of patients with psychosis.


Asunto(s)
Glutamina , Trastornos Psicóticos , Humanos , Adulto Joven , Adulto , Glutamina/metabolismo , Trastornos Psicóticos/metabolismo , Encéfalo/metabolismo , Ácido Glutámico/metabolismo , Giro del Cíngulo/metabolismo , Ácido Aspártico/metabolismo , Glutatión/metabolismo
3.
Magn Reson Med ; 90(3): 814-822, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37249071

RESUMEN

PURPOSE: To develop a 3D downfield (DF) MRSI protocol with whole brain coverage and post-processing pipeline for creation of metabolite maps. METHODS: A 3D, circularly phase-encoded version of the previously developed 2D DF MRSI sequence with 1 3 ‾ 3 1 ‾ $$ 1\overline{3}3\overline{1} $$ spectral-spatial excitation and frequency selective refocusing was implemented and tested in five healthy volunteers at 3T. The DF metabolite maps with a nominal spatial resolution of 0.7 cm3 were recorded in eight slices at 3T in a scan time of 22 m 40 s. An MRSI post-processing pipeline was developed to create DF metabolite maps. Metabolite concentrations and uncertainty estimates were compared between region differences for nine DF peaks. RESULTS: LCModel analysis showed Cramer Rao lower bounds average values of 3%-4% for protein amide resonances in the three selected regions (anterior cingulate, dorsolateral prefrontal cortex, and centrum semiovale); Cramer Rao lower bounds were somewhat higher for individual peaks but for the most part were less than 20%. While DF concentration maps were visually quite homogeneous throughout the brain, general linear regression analysis corrected for multiple comparisons found significant differences between centrum semiovale and dorsolateral prefrontal cortex for peaks at 7.09 ppm (p = 0.014), 7.90 ppm (p = 0.009), 8.18 ppm (p = 0.009), combined amides (p = 0.009), and between anterior cingulate and dorsolateral prefrontal cortex for the 7.30 ppm peak (p = 0.020). Cramer Rao lower bounds values were not significantly different between brain regions for any of the DF peaks. CONCLUSION: The 3D DF MRSI of the human brain at 3T with wide spatial coverage for the mapping of exchangeable amide and other resonances is feasible at a nominal spatial resolution of 0.7 cm3 .


Asunto(s)
Encéfalo , Protones , Humanos , Espectroscopía de Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Mapeo Encefálico/métodos , Cuerpo Calloso , Imagen por Resonancia Magnética/métodos
4.
Ann Neurol ; 2022 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-36511514

RESUMEN

OBJECTIVE: This study was undertaken to identify magnetic resonance (MR) metrics that are most sensitive to early changes in the brain in spinocerebellar ataxia type 1 (SCA1) and type 3 (SCA3) using an advanced multimodal MR imaging (MRI) protocol in the multisite trial setting. METHODS: SCA1 or SCA3 mutation carriers and controls (n = 107) underwent MR scanning in the US-European READISCA study to obtain structural, diffusion MRI, and MR spectroscopy data using an advanced protocol at 3T. Morphometric, microstructural, and neurochemical metrics were analyzed blinded to diagnosis and compared between preataxic SCA (n = 11 SCA1, n = 28 SCA3), ataxic SCA (n = 14 SCA1, n = 37 SCA3), and control (n = 17) groups using nonparametric testing accounting for multiple comparisons. MR metrics that were most sensitive to preataxic abnormalities were identified using receiver operating characteristic (ROC) analyses. RESULTS: Atrophy and microstructural damage in the brainstem and cerebellar peduncles and neurochemical abnormalities in the pons were prominent in both preataxic groups, when patients did not differ from controls clinically. MR metrics were strongly associated with ataxia symptoms, activities of daily living, and estimated ataxia duration. A neurochemical measure was the most sensitive metric to preataxic changes in SCA1 (ROC area under the curve [AUC] = 0.95), and a microstructural metric was the most sensitive metric to preataxic changes in SCA3 (AUC = 0.92). INTERPRETATION: Changes in cerebellar afferent and efferent pathways underlie the earliest symptoms of both SCAs. MR metrics collected with a harmonized advanced protocol in the multisite trial setting allow detection of disease effects in individuals before ataxia onset with potential clinical trial utility for subject stratification. ANN NEUROL 2022.

5.
Magn Reson Med ; 87(4): 1661-1672, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34971460

RESUMEN

PURPOSE: To develop an MRSI technique capable of mapping downfield proton resonances in the human brain. METHODS: A spectral-spatial excitation and frequency-selective refocusing scheme, in combination with 2D phase encoding, was developed for mapping of downfield resonances without any perturbation of the water magnetization. An alternative scheme using spectral-spatial refocusing was also investigated for simultaneous detection of both downfield and upfield resonances. The method was tested in 5 healthy human volunteers. RESULTS: Downfield metabolite maps with a nominal spatial resolution of 1.5 cm3 were recorded at 3 T in a scan time of 12 minutes. Cramer-Rao lower bounds for nine different downfield peaks were 20% or less over a single supraventricular slice. Downfield spectral profiles were similar to those in the literature recorded previously using single-voxel localization methods. The same approach was also used for upfield MRSI, and simultaneous upfield and downfield acquisitions. CONCLUSION: The developed MRSI pulse sequence was shown to be an efficient way of rapidly mapping downfield resonances in the human brain at 3 T, maximizing sensitivity through the relaxation enhancement effect. Because the MRSI approach is efficient in terms of data collection and can be readily implemented at short TE, somewhat higher spatial resolution can be achieved than has been reported in previous single-voxel downfield MRS studies. With this approach, nine downfield resonances could be mapped in a single slice for the first time using MRSI at 3 T.


Asunto(s)
Terapia de Protones , Protones , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos
6.
NMR Biomed ; 35(1): e4618, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34558129

RESUMEN

J-difference-edited spectroscopy is a valuable approach for the in vivo detection of γ-aminobutyric-acid (GABA) with magnetic resonance spectroscopy (MRS). A recent expert consensus article recommends linear combination modeling (LCM) of edited MRS but does not give specific details regarding implementation. This study explores different modeling strategies to adapt LCM for GABA-edited MRS. Sixty-one medial parietal lobe GABA-edited MEGA-PRESS spectra from a recent 3-T multisite study were modeled using 102 different strategies combining six different approaches to account for co-edited macromolecules (MMs), three modeling ranges, three baseline knot spacings, and the use of basis sets with or without homocarnosine. The resulting GABA and GABA+ estimates (quantified relative to total creatine), the residuals at different ranges, standard deviations and coefficients of variation (CVs), and Akaike information criteria, were used to evaluate the models' performance. Significantly different GABA+ and GABA estimates were found when a well-parameterized MM3co basis function was included in the model. The mean GABA estimates were significantly lower when modeling MM3co , while the CVs were similar. A sparser spline knot spacing led to lower variation in the GABA and GABA+ estimates, and a narrower modeling range-only including the signals of interest-did not substantially improve or degrade modeling performance. Additionally, the results suggest that LCM can separate GABA and the underlying co-edited MM3co . Incorporating homocarnosine into the modeling did not significantly improve variance in GABA+ estimates. In conclusion, GABA-edited MRS is most appropriately quantified by LCM with a well-parameterized co-edited MM3co basis function with a constraint to the nonoverlapped MM0.93 , in combination with a sparse spline knot spacing (0.55 ppm) and a modeling range of 0.5-4 ppm.


Asunto(s)
Espectroscopía de Resonancia Magnética/métodos , Ácido gamma-Aminobutírico/metabolismo , Humanos , Modelos Lineales
7.
Mol Psychiatry ; 26(7): 3502-3511, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33077854

RESUMEN

Involvement of oxidative stress in the pathophysiology of schizophrenia (SZ) is suggested by studies of peripheral tissue. Nonetheless, it is unclear how such biological changes are linked to relevant, pathological neurochemistry, and brain function. We designed a multi-faceted study by combining biochemistry, neuroimaging, and neuropsychology to test how peripheral changes in a key marker for oxidative stress, glutathione (GSH), may associate with central neurochemicals or neuropsychological performance in health and in SZ. GSH in dorsal anterior cingulate cortex (dACC) was acquired as a secondary 3T 1H-MRS outcome using a MEGA-PRESS sequence. Fifty healthy controls and 46 patients with SZ were studied cross-sectionally, and analyses were adjusted for effects of confounding variables. We observed lower peripheral total GSH in SZ compared to controls in extracellular (plasma) and intracellular (lymphoblast) pools. Total GSH levels in plasma positively correlated with composite neuropsychological performance across the total population and within patients. Total plasma GSH levels were also positively correlated with the levels of Glx in the dACC across the total population, as well as within each individual group (controls, patients). Furthermore, the levels of dACC Glx and dACC GSH positively correlated with composite neuropsychological performance in the patient group. Exploring the relationship between systemic oxidative stress (in particular GSH), central glutamate, and cognition in SZ will benefit further from assessment of patients with more varied neuropsychological performance.


Asunto(s)
Esquizofrenia , Encéfalo/diagnóstico por imagen , Cognición , Ácido Glutámico , Glutatión , Giro del Cíngulo , Humanos
8.
Magn Reson Med ; 86(5): 2339-2352, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34184324

RESUMEN

PURPOSE: In localized MRS, spurious echo artifacts commonly occur when unsuppressed signal outside the volume of interest is excited and refocused. In the spectral domain, these signals often overlap with metabolite resonances and hinder accurate quantification. Because the artifacts originate from regions separate from the target MRS voxel, this work proposes that sensitivity encoding based on receive-coil sensitivity profiles may be used to separate these signal contributions. METHODS: Numerical simulations were performed to explore the effect of sensitivity-encoded separation for unknown artifact regions. An imaging-based approach was developed to identify regions that may contribute to spurious echo artifacts, and tested for sensitivity-based unfolding of signal on six data sets from three brain regions. Spectral data reconstructed using the proposed method ("ERASE") were compared with the standard coil combination. RESULTS: The method was able to fully unfold artifact signals if regions were known a priori. Mismatch between estimated and true artifact regions reduced the efficiency of removal, yet metabolite signals were unaffected. Water suppression imaging was able to identify regions of unsuppressed signal, and ERASE (from up to eight regions) led to visible removal of artifacts relative to standard reconstruction. Fitting errors across major metabolites were also lower; for example, Cramér-Rao lower bounds of myo-inositol were 13.7% versus 17.5% for ERASE versus standard reconstruction, respectively. CONCLUSION: The ERASE reconstruction tool was demonstrated to reduce spurious echo artifacts in single-voxel MRS. This tool may be incorporated into standard workflows to improve spectral quality when hardware limitations or other factors result in out-of-voxel signal contamination.


Asunto(s)
Artefactos , Encéfalo , Encéfalo/diagnóstico por imagen , Agua
9.
NMR Biomed ; 34(5): e4309, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-32350978

RESUMEN

Magnetic resonance spectroscopic imaging (MRSI) offers considerable promise for monitoring metabolic alterations associated with disease or injury; however, to date, these methods have not had a significant impact on clinical care, and their use remains largely confined to the research community and a limited number of clinical sites. The MRSI methods currently implemented on clinical MRI instruments have remained essentially unchanged for two decades, with only incremental improvements in sequence implementation. During this time, a number of technological developments have taken place that have already greatly benefited the quality of MRSI measurements within the research community and which promise to bring advanced MRSI studies to the point where the technique becomes a true imaging modality, while making the traditional review of individual spectra a secondary requirement. Furthermore, the increasing use of biomedical MR spectroscopy studies has indicated clinical areas where advanced MRSI methods can provide valuable information for clinical care. In light of this rapidly changing technological environment and growing understanding of the value of MRSI studies for biomedical studies, this article presents a consensus from a group of experts in the field that reviews the state-of-the-art for clinical proton MRSI studies of the human brain, recommends minimal standards for further development of vendor-provided MRSI implementations, and identifies areas which need further technical development.


Asunto(s)
Consenso , Espectroscopía de Resonancia Magnética , Neuroimagen , Encéfalo/diagnóstico por imagen , Testimonio de Experto , Humanos , Metaboloma
10.
NMR Biomed ; 34(5): e4218, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-31854045

RESUMEN

The semi-adiabatic localization by adiabatic selective refocusing (sLASER) sequence provides single-shot full intensity signal with clean localization and minimal chemical shift displacement error and was recommended by the international MRS Consensus Group as the preferred localization sequence at high- and ultra-high fields. Across-vendor standardization of the sLASER sequence at 3 tesla has been challenging due to the B1 requirements of the adiabatic inversion pulses and maximum B1 limitations on some platforms. The aims of this study were to design a short-echo sLASER sequence that can be executed within a B1 limit of 15 µT by taking advantage of gradient-modulated RF pulses, to implement it on three major platforms and to evaluate the between-vendor reproducibility of its perfomance with phantoms and in vivo. In addition, voxel-based first and second order B0 shimming and voxel-based B1 adjustments of RF pulses were implemented on all platforms. Amongst the gradient-modulated pulses considered (GOIA, FOCI and BASSI), GOIA-WURST was identified as the optimal refocusing pulse that provides good voxel selection within a maximum B1 of 15 µT based on localization efficiency, contamination error and ripple artifacts of the inversion profile. An sLASER sequence (30 ms echo time) that incorporates VAPOR water suppression and 3D outer volume suppression was implemented with identical parameters (RF pulse type and duration, spoiler gradients and inter-pulse delays) on GE, Philips and Siemens and generated identical spectra on the GE 'Braino' phantom between vendors. High-quality spectra were consistently obtained in multiple regions (cerebellar white matter, hippocampus, pons, posterior cingulate cortex and putamen) in the human brain across vendors (5 subjects scanned per vendor per region; mean signal-to-noise ratio > 33; mean water linewidth between 6.5 Hz to 11.4 Hz). The harmonized sLASER protocol is expected to produce high reproducibility of MRS across sites thereby allowing large multi-site studies with clinical cohorts.


Asunto(s)
Rayos Láser , Imagen por Resonancia Magnética/normas , Adulto , Simulación por Computador , Creatinina/metabolismo , Humanos , Metaboloma , Fantasmas de Imagen , Ondas de Radio , Estándares de Referencia , Relación Señal-Ruido
11.
J Neurovirol ; 26(3): 382-390, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32270469

RESUMEN

The causes of cognitive impairment among older HIV+ individuals may overlap with causes among elderly HIV seronegative (HIV-) individuals. The objective of this study was to determine if beta-amyloid (Aß) deposition measured by [18F] AV-45 (florbetapir) positron emission tomography (PET) is increased in older HIV+ individuals compared to HIV- individuals. Forty-eight HIV+ and 25 HIV- individuals underwent [18F] AV-45 PET imaging. [18F] AV-45 binding to Aß was measured by standardized uptake value ratios (SUVR) relative to the cerebellum in 16 cortical and subcortical regions of interest. Global and regional cortical SUVRs were compared by (1) serostatus, (2) HAND stage, and (3) age decade, comparing individuals in their 50s and > 60s. There were no differences in median global cortical SUVR stratified by HIV serostatus or HAND stage. The proportion of HIV+ participants in their 50s with elevated global amyloid uptake (SUVR > 1.40) was significantly higher than the proportion in HIV- participants (67% versus 25%, p = 0.04), and selected regional SUVR values were also higher (p < 0.05) in HIV+ compared to HIV- participants in their 50s. However, these group differences were not seen in participants in their 60s. In conclusion, PET imaging found no differences in overall global Aß deposition stratified by HIV serostatus or HAND stage. Although there was some evidence of increased Aß deposition in HIV+ individuals in their 50s compared to HIV- individuals which might indicate premature aging, the most parsimonious explanation for this is the relatively small sample size in this cross-sectional cohort study.


Asunto(s)
Péptidos beta-Amiloides/metabolismo , Mapeo Encefálico/métodos , Disfunción Cognitiva/diagnóstico por imagen , Infecciones por VIH/diagnóstico por imagen , VIH/patogenicidad , Anciano , Compuestos de Anilina , Transporte Biológico , Encéfalo , Disfunción Cognitiva/metabolismo , Disfunción Cognitiva/fisiopatología , Disfunción Cognitiva/virología , Estudios Transversales , Glicoles de Etileno , Femenino , Radioisótopos de Flúor , VIH/crecimiento & desarrollo , Infecciones por VIH/metabolismo , Infecciones por VIH/fisiopatología , Infecciones por VIH/virología , Humanos , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Índice de Severidad de la Enfermedad
12.
Neuroimage ; 202: 116141, 2019 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-31479753

RESUMEN

Edited magnetic resonance spectroscopic imaging (MRSI) is capable of mapping the distribution of low concentration metabolites such as gamma-aminobutyric acid (GABA) or and glutathione (GSH), but is prone to subtraction artifacts due to head motion or other instabilities. In this study, a retrospective motion compensation algorithm for edited MRSI is proposed. The algorithm identifies movement-affected signals by comparing residual water and lipid peaks between different transients recorded at the same point in k-space, and either phase corrects, replaces or removes affected spectra prior to spatial Fourier transformation. The method was tested on macromolecule-unsuppressed GABA-edited spin-echo MR spectroscopic imaging data acquired from 8 healthy adults scanned at 3T. Relative to non-motion compensated data sets, the motion compensated data had significantly less subtraction artifacts across subjects. The residual choline (Cho) peak in the spectrum (which is well resolved from as a different chemical shift from GABA and is completely absent in a spectrum without subtraction artifact) was used as a metric of motion artifact severity. The normalized Cho area was 5.14 times lower with motion compensation than without motion compensation. A 'removal-only' version of the technique is also shown to be promising in removing motion-corrupted artifacts in a GSH-edited MRSI acquisition acquired in 1 healthy subject. This study introduces a motion compensation technique and demonstrates that retrospective compensation in k-space is possible and significantly reduces the amount of subtraction artifacts in the resulting edited spectra.


Asunto(s)
Encéfalo/metabolismo , Procesamiento de Imagen Asistido por Computador/métodos , Espectroscopía de Resonancia Magnética/métodos , Adulto , Algoritmos , Artefactos , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Ácido gamma-Aminobutírico/metabolismo
13.
Neuroimage ; 191: 537-548, 2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-30840905

RESUMEN

Accurate and reliable quantification of brain metabolites measured in vivo using 1H magnetic resonance spectroscopy (MRS) is a topic of continued interest. Aside from differences in the basic approach to quantification, the quantification of metabolite data acquired at different sites and on different platforms poses an additional methodological challenge. In this study, spectrally edited γ-aminobutyric acid (GABA) MRS data were analyzed and GABA levels were quantified relative to an internal tissue water reference. Data from 284 volunteers scanned across 25 research sites were collected using GABA+ (GABA + co-edited macromolecules (MM)) and MM-suppressed GABA editing. The unsuppressed water signal from the volume of interest was acquired for concentration referencing. Whole-brain T1-weighted structural images were acquired and segmented to determine gray matter, white matter and cerebrospinal fluid voxel tissue fractions. Water-referenced GABA measurements were fully corrected for tissue-dependent signal relaxation and water visibility effects. The cohort-wide coefficient of variation was 17% for the GABA + data and 29% for the MM-suppressed GABA data. The mean within-site coefficient of variation was 10% for the GABA + data and 19% for the MM-suppressed GABA data. Vendor differences contributed 53% to the total variance in the GABA + data, while the remaining variance was attributed to site- (11%) and participant-level (36%) effects. For the MM-suppressed data, 54% of the variance was attributed to site differences, while the remaining 46% was attributed to participant differences. Results from an exploratory analysis suggested that the vendor differences were related to the unsuppressed water signal acquisition. Discounting the observed vendor-specific effects, water-referenced GABA measurements exhibit similar levels of variance to creatine-referenced GABA measurements. It is concluded that quantification using internal tissue water referencing is a viable and reliable method for the quantification of in vivo GABA levels.


Asunto(s)
Encéfalo/metabolismo , Espectroscopía de Resonancia Magnética/normas , Ácido gamma-Aminobutírico/análisis , Adolescente , Adulto , Conjuntos de Datos como Asunto , Femenino , Humanos , Espectroscopía de Resonancia Magnética/métodos , Masculino , Valores de Referencia , Agua , Adulto Joven
14.
Magn Reson Med ; 82(4): 1278-1287, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31148254

RESUMEN

PURPOSE: An L2-regularization based postprocessing method is proposed and tested for removal of residual or unsuppressed water signals in proton MR spectroscopic imaging (MRSI) data recorded from the human brain at 3T. METHODS: Water signals are removed by implementation of the L2 regularization using a synthesized water-basis matrix that is orthogonal to metabolite signals of interest in the spectral dimension. Simulated spectra with variable water amplitude and in vivo brain MRSI datasets were used to demonstrate the proposed method. Results were compared with two commonly-used postprocessing methods for removing water signals. RESULTS: The L2 method yielded metabolite signals that were close to true values for the simulated spectra. Residual/unsuppressed water signals in human brain short- and long-echo time MRSI datasets were efficiently removed by the proposed method allowing good quality metabolite maps to be reconstructed with minimized contamination from water signals. Significant differences of the creatine signal were observed between brain long-echo time MRSI without and with water saturation, attributable to the previously described magnetization transfer effect. CONCLUSIONS: With usage of a synthesized water matrix generated based on reasonable prior knowledge about water and metabolite resonances, the L2 method is shown to be an effective way to remove water signals from MRSI of the human brain.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Agua/química , Adulto , Algoritmos , Encéfalo/diagnóstico por imagen , Creatina/química , Humanos , Masculino , Procesamiento de Señales Asistido por Computador
15.
Magn Reson Med ; 81(1): 69-78, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30246265

RESUMEN

PURPOSE: To obtain high-resolution Cr and PCr maps of mouse skeletal muscle using a polynomial and Lorentzian line-shape fitting (PLOF) CEST method. METHODS: Wild-type mice and guanidinoacetate N-methyltransferase-deficient (GAMT-/-) mice that have low Cr and PCr concentrations in muscle were used to assign the Cr and PCr peaks in the Z-spectrum at 11.7 T. A PLOF method was proposed to simultaneously extract and quantify the Cr and PCr by assuming a polynomial function for the background and 2 Lorentzian functions for the CEST peaks at 1.95 ppm and 2.5 ppm. RESULTS: The Z-spectra of phantoms revealed that PCr has 2 CEST peaks (2 ppm and 2.5 ppm), whereas Cr only showed 1 peak at 2 ppm. Comparison of the Z-spectra of wild-type and GAMT-/- mice indicated that, contrary to brain, there was no visible protein guanidinium peak in the skeletal-muscle Z-spectrum, which allowed us to extract clean PCr and Cr CEST signals. High-resolution PCr and Cr concentration maps of mouse skeletal muscle were obtained by the PLOF CEST method after calibration with in vivo MRS. CONCLUSIONS: The PLOF method provides an efficient way to map Cr and PCr concentrations simultaneously in the skeletal muscle at high MRI field.


Asunto(s)
Creatina/análisis , Espectroscopía de Resonancia Magnética/métodos , Músculo Esquelético/metabolismo , Fosfocreatina/análisis , Algoritmos , Animales , Medios de Contraste , Femenino , Guanidinoacetato N-Metiltransferasa/genética , Guanidinoacetato N-Metiltransferasa/metabolismo , Ratones , Ratones Endogámicos BALB C , Modelos Teóricos , Fantasmas de Imagen , Fosfocreatina/análogos & derivados , Fosfocreatina/sangre
16.
Magn Reson Med ; 82(1): 21-32, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30793803

RESUMEN

PURPOSE: To evaluate the feasibility of simultaneous MR spectroscopic imaging (MRSI) of gamma-aminobutyric acid (GABA) and glutathione (GSH) in the human brain using Hadamard Encoding and Reconstruction of MEGA-Edited Spectroscopy (HERMES). METHODS: Point RESolved Spectroscopy (PRESS)-localized MRSI was performed in GABA and GSH phantoms and in the human brain (n = 3) using HERMES editing and compared to conventional MEGA editing of each metabolite. Multiplet patterns, signal intensities, and metabolite crosstalk were compared between methods. GABA+ and GSH levels were compared between methods for bias and variability. Linear regression of HERMES-MRSI GABA+/H2 O and GSH/H2 O versus gray matter (GM) fraction were performed to assess differences between GM and white matter (WM). RESULTS: Phantom HERMES-MRSI scans gave comparable GABA+ and GSH signals to MEGA-MRSI across the PRESS-localized volume. In vivo, HERMES-reconstructed GABA+ and GSH values had minimal measurement bias and variability relative to MEGA-MRSI. Intersubject coefficients of variation (CV) from two regions within the PRESS-localized volume for HERMES and MEGA were 6-12% for GABA+ and 6-19% for GSH. Interregion CVs were 5-15% for GABA+ and 3-17% for GSH. The GABA+/H2 O and GSH/H2 O ratios were ~1.8 times higher and ~1.9 times higher, respectively, in GM than in WM. CONCLUSION: HERMES-MRSI of GABA+ and GSH was found to be practical in the human brain with minimal measurement bias and comparable variability to separate MEGA-edited acquisitions of each metabolite performed in double the scan time. The HERMES-MRSI is a promising method for simultaneously mapping the distribution of multiple low-concentration metabolites.


Asunto(s)
Glutatión , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Ácido gamma-Aminobutírico , Adulto , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Química Encefálica , Femenino , Glutatión/análisis , Glutatión/química , Glutatión/metabolismo , Humanos , Masculino , Fantasmas de Imagen , Ácido gamma-Aminobutírico/análisis , Ácido gamma-Aminobutírico/química , Ácido gamma-Aminobutírico/metabolismo
17.
Magn Reson Med ; 82(2): 527-550, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30919510

RESUMEN

Proton MRS (1 H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good-quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi-adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0 ) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Encéfalo/metabolismo , Consenso , Humanos , Protones
18.
NMR Biomed ; 32(2): e4040, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30489668

RESUMEN

To date, the majority of MRS reproducibility studies have been conducted in healthy younger adults, with only a few conducted in older adults at 3 T. With the growing interest in applying MRS methods to study the longitudinal course and effects of treatments in neurodegenerative disease, it is important to establish reproducibility in age-matched controls, especially in older individuals. In this study, spectroscopic data were acquired using a stimulated echo acquisition mode (STEAM) localization technique in two regions (anterior and posterior cingulate cortices-ACC, PCC, respectively) in 10 healthy, cognitively normal older adults (64 ± 8.1 years). Reproducibility was assessed via mean coefficients of variation (CVs) and relative differences (RDs) calculated across two visits performed 2-3 months apart. Metabolites with high signal-to-noise ratio (SNR) such as NAA, tCho, and Glu had mean CVs of 10% or less and mean RDs of 15% or less across both regions. Metabolites with lower SNR such as GABA and Gln had slightly higher mean CVs of 22% or less and mean RDs of 27% or less across both regions. These results demonstrate the feasibility of acquiring MRS data at 7 T in older subjects, and establish that the spectroscopic data are reproducible in both the ACC and PCC in older, healthy subjects to the same extent as in previous studies in young subjects.


Asunto(s)
Encéfalo/diagnóstico por imagen , Espectroscopía de Resonancia Magnética , Anciano , Anciano de 80 o más Años , Creatina/metabolismo , Femenino , Giro del Cíngulo/metabolismo , Humanos , Masculino , Metaboloma , Persona de Mediana Edad , Reproducibilidad de los Resultados
20.
Magn Reson Med ; 80(4): 1298-1306, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29446118

RESUMEN

PURPOSE: To develop and investigate a novel water suppression sequence with hypergeometric pulses at 3 T. METHODS: Simulations were used to optimize the delays and amplitudes of 5 hypergeometric prepulses, to minimize the residual water over a range of T1 and B1 values. Single-voxel data with hypergeometric water suppression (HGWS) prepulses were acquired in the centrum semiovale, 2 parietal regions, and insula of 7 subjects, and compared with VAPOR water suppression. Magnetic resonance spectroscopic imaging (MRSI) data using both VAPOR and HGWS prepulses were also collected and compared. Water suppression performance was calculated as the residual water peak height relative to the unsuppressed water peak. MRSI voxel-by-voxel comparison was performed by calculating the ratio between HGWS and VAPOR residual water peaks. RESULTS: In simulations, HGWS and VAPOR are insensitive to B1 and water T1 variations, but with no B1 variation, HGWS has a lower average residual water fraction (0.0033) than that of VAPOR (0.0091). In single-voxel acquisitions, HGWS performs better than VAPOR in all regions with a 2.3-fold to 5.7-fold lower residual water. In MRSI acquisitions, HGWS performs on average 2.3-fold better than VAPOR in 98.9% of the voxels. CONCLUSION: HGWS provides better water suppression than VAPOR in both single-voxel and multivoxel acquisitions with a shorter sequence duration.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Femenino , Humanos , Masculino , Ondas de Radio , Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA