Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Pacing Clin Electrophysiol ; 39(7): 680-9, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27062583

RESUMEN

BACKGROUND: Left ventricular ejection fraction (LVEF) recovers during follow-up in a significant proportion of patients implanted with a cardioverter defibrillator (ICD) for primary prevention. Little is known about the midterm arrhythmic risk in this population, particularly in relation to the presence or absence of ischemic cardiomyopathy. METHODS AND RESULTS: We retrospectively analyzed 286 patients with an ICD implanted for primary prevention between 2002 and 2010. Patients were divided into two groups based on their last LVEF assessment: (1) Recovery, defined as an LVEF > 35%; and (2) No-Recovery, defined as an LVEF ≤ 35%. Kaplan-Meir curves and multivariate Cox regression analysis were performed separately for patients with ischemic (211 patients) and nonischemic (75 patients) cardiomyopathy. Forty-nine patients (17.1%) had LVEF recovery to >35% at last follow-up. Overall, 72 patients (25.2%) experienced ventricular arrhythmias requiring ICD therapy during a median follow-up of 4.4 years. With multivariate Cox regression, LVEF recovery was associated with a lower arrhythmic risk in the whole cohort (hazard ratio [HR]: 0.38 [0.13-0.85]; P = 0.02) and in the nonischemic cardiomyopathy cohort (HR: 0.10 [0.005-0.55]; P = 0.005), but not in the ischemic cardiomyopathy cohort (HR: 0.84 [0.25-2.10]; P = 0.74). CONCLUSION: In conclusion, patients with nonischemic cardiomyopathy who improved their LVEF to >35% after primary prevention ICD implantation were at very low absolute arrhythmic risk. Our study raises the possibility that the LVEF cutoff to safely withhold ICD replacement might be higher in patients with ischemic compared to nonischemic cardiomyopathy. This will need to be confirmed in prospective studies.


Asunto(s)
Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/prevención & control , Cardiomiopatías/mortalidad , Cardiomiopatías/prevención & control , Desfibriladores Implantables/estadística & datos numéricos , Volumen Sistólico , Anciano , Arritmias Cardíacas/diagnóstico por imagen , Cardiomiopatías/diagnóstico por imagen , Comorbilidad , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Prevención Primaria , Quebec/epidemiología , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Resultado del Tratamiento
2.
J Cardiovasc Imaging ; 32(1): 2, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38907302

RESUMEN

BACKGROUND: Mitral annulus (MA) area is derived during transthoracic echocardiography (TTE) assuming of a circular shape using the MA diameter from the apical 4 chamber (A4c) view. Since the MA is not a circular structure, we hypothesized that an elliptical model using parasternal long-axis (PLAX) and apical 2 chamber (A2c) view measured MA diameters would have better agreement with 3-dimensional transesophageal echocardiography (3D TEE) measured MA in degenerative mitral valve disease (DMVD). METHODS: Seventy-six patients with moderate-to-severe DMVD had 2D TTE and 3D TEE performed. MA area was measured retrospectively using semi-automatic modeling of 3D data (3D TEEsa) and considered as the reference method. MA diameters were measured using different 2D TTE views. MA area was calculated using assumptions of a circular or an elliptical shape. 2D TTE derived and 3D TEEsa. MA areas were compared using linear regression and Bland-Altman analysis. RESULTS: The median MA area measured at 3D TEEsa was 1,386 (1,293-1,673) mm2. With 2D TTE, the circular model using A4c view diameter resulted in a small systematic underestimation of MA area (6%), while the elliptical model using PLAX and A2c diameters resulted in 25% systematic underestimation. The standard deviations of the distributions of inter-method differences were wide for all 2D TTE methods (265-289 mm2) when compared to 3D TEEsa, indicating imprecision. CONCLUSIONS: When compared with 3D TEEsa modeling of the MA as the reference, the assumption of a circular shape using A4c TTE view diameter was the method with the least systematic error to assess MA area in DMVD and moderate to severe regurgitation.

3.
Int J Cardiovasc Imaging ; 39(9): 1707-1717, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37572176

RESUMEN

3D-transesophageal echocardiography (3D-TEE) is an alternative to multidetector row computed tomography (MDCT) for aortic annulus (AoA) sizing in preparation for Transcatheter aortic valve implantation (TAVI). We aim to evaluate how the fully automated (auto) and semi-automated (SA) TEE methods perform compared to conventional manual TEE method and the gold standard MDCT for annulus sizing both in expert and novice operators. In this prospective cohort study, eighty-nine patients with severe aortic stenosis underwent multimodality imaging with 3D-TEE and MDCT. Annular measurements were collected by expert echocardiographers using 3D auto, SA and manual methods and compared to MDCT. A novice in the field of echocardiography retrospectively measured the AoA for all patients using the same methods. TEE measurements, independently of the method used, had good to very good agreement to MDCT. They significantly underestimated aortic annular area and circumference vs. MDCT with the auto method underestimating it the most and the manual method the least (6.5% and 1.3% respectively for area and circumference). For experts, the manual TEE method offered the least systematic bias while the SA method had narrower limits of agreement (LOA). For the novice operator, SA method provided the least bias and narrower LOA vs. MDCT. There is good agreement between novice and experts for all 3 TEE methods but better agreement with auto and SA methods as opposed to manual one. Our study supports the use of 3D-TEE as a complementary method to MDCT for aortic annular sizing. The newer auto and SA software, that requires minimal operator intervention, is an easy to use, reliable and reproducible tool for aortic annulus sizing for experienced operators, and especially less experienced ones.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía Tridimensional , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Estudios Prospectivos , Valor Predictivo de las Pruebas , Ecocardiografía Tridimensional/métodos , Programas Informáticos , Ecocardiografía Transesofágica/métodos , Tomografía Computarizada Multidetector/métodos
4.
Transfusion ; 52(4): 739-41, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22082044

RESUMEN

BACKGROUND: Refractoriness to platelet (PLT) transfusion is a feared, life-threatening complication in hematology-oncology patients. Despite increased PLT requirement and treatment costs, the clinical management is difficult and these patients had less favorable outcomes. CASE REPORT: We report on the efficacy of the thrombopoietic agent romiplostim in a patient with acute myeloid leukemia with chemotherapy-induced transfusion-refractory thrombocytopenia. CONCLUSION: Romiplostim could be very helpfull in the management of AML patients with transfusion refractory thrombocytopenia.


Asunto(s)
Leucemia Mieloide Aguda/tratamiento farmacológico , Transfusión de Plaquetas , Receptores Fc/uso terapéutico , Receptores de Trombopoyetina/agonistas , Proteínas Recombinantes de Fusión/uso terapéutico , Trombocitopenia/tratamiento farmacológico , Trombopoyetina/uso terapéutico , Femenino , Humanos , Persona de Mediana Edad
5.
JACC Cardiovasc Imaging ; 9(7): 797-805, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27209111

RESUMEN

OBJECTIVES: This study sought to assess the survival benefit associated with aortic valve replacement (AVR) according to different strata of echocardiographic parameters of aortic stenosis (AS) severity, and especially in patients with an aortic valve area (AVA) comprised between 0.8 cm(2) and 1 cm(2). BACKGROUND: Discordant findings between AVA (≤1.0 cm(2)) and mean gradient (MG) (<40 mm Hg) raise uncertainty regarding the actual severity of AS. Some studies suggested that the AVA threshold value to define severe AS should be decreased to 0.8 cm(2) to reconcile these discordances. METHODS: A total of 1,710 patients with documented moderate to severe AS by Doppler echocardiography were separated into 4 strata of AS severity based alternatively on AVA, indexed AVA, MG, or peak aortic jet velocity (Vpeak). We compared the survival rates of medically versus surgically treated patients. To eliminate covariate differences that may lead to biased estimates of treatment effect, a propensity matching with a greedy 5-to-1 digit-matching algorithm was used. RESULTS: Mean AVA was 0.9 ± 0.3 cm(2), mean MG 33 ± 18 mm Hg, and mean Vpeak 3.6 ± 0.9 m/s. A total of 1,030 (60%) patients underwent AVR within 3 months following echocardiographic evaluation. During a mean follow-up of 4.4 ± 3.0 years there were 469 deaths. Patients with an AVA between 0.8 cm(2) and 1.0 cm(2) had a significant observed survival benefit with AVR (hazard ratio: 0.37 [95% confidence interval: 0.21 to 0.63]; p = 0.0002). AVR was also associated with improved survival in patients with MG between 25 mm Hg and 40 mm Hg or Vpeak between 3 m/s and 4 m/s, but only in patients with concomitant AVA ≤1 cm(2) (p = 0.001 vs. p = 0.46 in patients with AVA >1 cm(2)). CONCLUSIONS: These results do not support decreasing the AVA threshold value for severity to 0.8 cm(2) and they confirm that AVR is associated with improved survival in a substantial number of patients with discordant aortic grading.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Implantación de Prótesis Vascular , Ecocardiografía Doppler , Anciano , Anciano de 80 o más Años , Algoritmos , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Distribución de Chi-Cuadrado , Femenino , Hemodinámica , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Puntaje de Propensión , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
6.
J Am Coll Cardiol ; 65(7): 645-53, 2015 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-25677424

RESUMEN

BACKGROUND: Low flow (LF) can occur with reduced (classic) or preserved (paradoxical) left ventricular ejection fraction (LVEF). OBJECTIVES: The objective of this study was to compare outcomes of patients with low ejection fraction (LEF), paradoxical low flow (PLF), and normal flow (NF) after aortic valve replacement (AVR). METHODS: We examined 1,154 patients with severe aortic stenosis (AS) who underwent AVR with or without coronary artery bypass grafting. RESULTS: Among these patients, 206 (18%) had LEF as defined by LVEF of <50%; 319 (28%) had PLF as defined by LVEF of ≥50% but stroke volume indexed to body surface area (SVi) of ≤35 ml ∙ m(-2); and 629 (54%) had NF, as defined by LVEF of ≥50% and SVi of >35 ml ∙ m(2). Aortic valve area was lower in low flow/LVEF groups (LEF: 0.71 ± 0.20 cm(2) and PLF: 0.65 ± 0.23 cm(2) vs. NF: 0.77 ± 0.18 cm(2); p < 0.001). The 30-day mortality was higher (p < 0.001) in LEF and PLF groups than in the NF group (6.3% and 6.3% vs. 1.8%, respectively). SVi and PLF group were independent predictors of operative mortality (odds ratio [OR]: 1.18, p < 0.05; and OR: 2.97, p = 0.004; respectively). At 5 years after AVR, overall survival was 72 ± 4% in LEF group, 81 ± 2% in PLF group, and 85 ± 2% in NF group (p < 0.0001). CONCLUSIONS: Patients with LEF or PLF AS have a higher operative risk, but pre-operative risk score accounted only for LEF and lower LVEF. Patients with LEF had the worst survival outcome, whereas patients with PLF and normal flow had similar survival rates after AVR. As a major predictor of perioperative mortality, SVi should be integrated in AS patients' pre-operative evaluation.


Asunto(s)
Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas , Volumen Sistólico/fisiología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Estudios de Cohortes , Puente de Arteria Coronaria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tasa de Supervivencia , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
7.
Exp Clin Transplant ; 12(6): 565-8, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24650294

RESUMEN

OBJECTIVES: Giant cell myocarditis is a rare and often fatal disorder. According to the American Heart Association, the American College of Cardiology Foundation, and the European Society of Cardiology scientific statements, an endomyocardial biopsy should be done to exclude giant cell myocarditis in unexplained new-onset heart failure of 2 weeks to 3 months duration associated with dilated left ventricle and new ventricular arrhythmias, or Mobitz type II second-degree, or third-degree atrioventricular heart block. CASE PRESENTATIONS: Two hundred thirty-five heart transplants were performed since May 1993 at the Institut universitaire de cardiologie et de pneumologie de Quebec, Canada. Giant cell myocarditis was found in the explanted hearts of 5 patients. The preoperative diagnosis of giant cell myocarditis was done by endomyocardial biopsy or at the installation of a left ventricular-assisted device. Patients had symptoms of progressive heart failure of subacute onset. Patients consulted at a mean 32 days after the onset of symptoms. Two patients neither had ventricular arrhythmia nor heart block. Two patients had ventricular arrhythmias and heart block; the other patient had symptomatic heart block. All patients had at least 2 echocardiographies. Two patients had an increase in left ventricular size, enough to reach the criteria of left ventricular dilatation according to the American Society of Echocardiography. During this time, left ventricular ejection fraction showed a rapid decline (mean 37% to 16%). CONCLUSIONS: Ventricular arrhythmia, heart block, and left ventricular dilatation initially can be absent in many patients having giant cell myocarditis with symptoms of progressive heart failure. Endo-myocardial biopsy should be quickly considered in patients with a rapid and dramatic decline of left ventricular ejection fraction, even in the absence of classic clinical and echocardiographic features of giant cell myocarditis to rapidly obtain the diagnosis of this rare but lethal disease.


Asunto(s)
Ecocardiografía , Células Gigantes , Miocarditis/diagnóstico , Miocardio/patología , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Biopsia , Resultado Fatal , Femenino , Células Gigantes/diagnóstico por imagen , Células Gigantes/patología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Trasplante de Corazón , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico , Hipertrofia Ventricular Izquierda/etiología , Hipertrofia Ventricular Izquierda/fisiopatología , Masculino , Persona de Mediana Edad , Miocarditis/complicaciones , Miocarditis/diagnóstico por imagen , Miocarditis/patología , Miocarditis/fisiopatología , Miocarditis/cirugía , Valor Predictivo de las Pruebas , Quebec , Volumen Sistólico , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/cirugía , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA