Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Opt Soc Am A Opt Image Sci Vis ; 39(6): 1053-1060, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-36215535

RESUMEN

Anomalous radiative transfer (ART) theory represents a generalization of classical radiative transfer theory. The present tutorial aims to show how Monte Carlo (MC) codes describing the transport of photons in anomalous media can be implemented. We show that the heart of the method involves suitably describing, in a "non-classical" manner, photon steps starting from fixed light sources or from boundaries separating regions of the medium with different optical properties. To give a better sense of the importance of these particular photon step lengths, we also show numerically that the described approach is essential in preserving the invariance property for light propagation. An interesting byproduct of the MC method for ART is that it allows us to simplify the structure of "classical" MC codes, utilized, for example, in biomedical optics.


Asunto(s)
Óptica y Fotónica , Fotones , Simulación por Computador , Método de Montecarlo , Dispersión de Radiación
2.
J Opt Soc Am A Opt Image Sci Vis ; 36(11): 1883-1891, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31873704

RESUMEN

In the present contribution, three means of measuring the geometrical and topological complexity of photons' paths in random media are proposed. This is realized by investigating the behavior of the average crossing number, the mean writhe, and the minimal crossing number of photons' paths generated by Monte Carlo (MC) simulations, for different sets of optical parameters. It is observed that the complexity of the photons' paths increases for increasing light source/detector spacing, and that highly "knotted" paths are formed. Due to the particular rules utilized to generate the MC photons' paths, the present results may have an interest not only for the biomedical optics community, but also from a pure mathematical point of view.


Asunto(s)
Fenómenos Ópticos , Fotones , Método de Montecarlo
3.
Appl Opt ; 58(15): 4143-4148, 2019 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-31158171

RESUMEN

In this paper, we derive some explicit analytical solutions to the P3 equations for the slab geometry that is illuminated by a collimated plane source. The resulting expressions for the total reflectance and transmittance are compared with the corresponding transport theory solution predicted by the Monte Carlo method. Further, for the special case of a non-absorbing anisotropically scattering slab, simple and accurate expressions in the P1 approximation are obtained, yielding for optically thick slabs, the typical behavior of Ohm's law. In view of the time domain, we present an alternative method to the classical frequency-domain approach avoiding the use of complex numbers.

4.
Opt Express ; 26(2): 744-761, 2018 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-29401955

RESUMEN

An heuristic model for ballistic photon detection in continuous-wave measurements of collimated transmittance through a slab is presented. The model is based on the small angle approximation and the diffusion equation and covers all the ranges of optical thicknesses of the slab from the ballistic to the diffusive regime. The performances of the model have been studied by means of comparisons with the results of gold standard Monte Carlo simulations for a wide range of optical thicknesses and two types of scattering functions. For a non-absorbing slab and field of view of the receiver less than 3° the model shows errors less than 15% for any value of the optical thickness. Even for an albedo value of 0.9, and field of view of the receiver less than 3° the model shows errors less than 20%. These results have been verified for a large set of scattering functions based on the Henyey-Greenstein model and Mie theory for spherical scatterers. The latter has also been used to simulate the scattering function of Intralipid, a diffusive material widely used as reference standard for tissue simulating phantoms. The proposed model represents an effective improvement compared to the existing literature.

5.
J Opt Soc Am A Opt Image Sci Vis ; 35(6): 895-902, 2018 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-29877332

RESUMEN

A generalized time-independent correlation transport equation (GCTE) is proposed for the field autocorrelation function. The GCTE generalizes various models for anomalous transport of photons and takes into account the possible presence of a static background. In a tutorial example, the GCTE is solved for a homogeneous semi-infinite medium in reflectance configuration through Monte Carlo simulations. The chosen anomalous photon transport model also includes the classic and the "generalized" Lambert-Beer's law (depending on the choice of parameters). A numerical algorithm allowing generation of the related anomalous random photon steps is also given. The clear influence of anomalous transport on the field autocorrelation function is shown and discussed for the proposed specific examples by comparing the general results with the classical case (Lambert-Beer's law).

6.
J Opt Soc Am A Opt Image Sci Vis ; 34(12): 2096-2101, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29240082

RESUMEN

In the present contribution, the theoretical relationship existing between the blood flow index measured by diffuse correlation spectroscopy and single-photon laser-Doppler flowmetry (SP-LDF) is investigated. A specific mathematical description that accounts for the properties of single-photon detectors for SP-LDP was developed. Static background has also been considered and, to the best of our knowledge, this has never been included before in SP-LDF analytical theories. The comparisons were realized for two SP-LDF implementations: for "classical" and "fast" algorithms. "Classical" SP-LDF is not sensitive to small changes on the number of detected speckles and coherence length of the laser, usually described by a unique parameter "beta." This is a strong point when assessing blood flow index, e.g., in humans, where "beta" is particularly difficult to be determined in real time. The proposed theory may be utilized, e.g., to investigate other SP-LDF setups and optical/physiological parameter ranges or, generally, to optimize real SP-LDF instrumentation.

7.
Appl Opt ; 56(4): 795-801, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-28158078

RESUMEN

A new correlation diffusion equation has been derived from a correlation transport equation allowing one to take into account the presence of moving scatterers and static background. Solutions for the reflectance from a semi-infinite medium have been obtained (point-like and ring detectors). The solutions have been tested by comparisons with "gold standard" Monte Carlo (MC) simulations. These formulas suitably describe the electric field autocorrelation function, for Brownian or random movement of the scatterers, even in the case where the probability for a photon to interact with a moving scatterer is very low. The proposed analytical models and the MC simulations show that the "classical" model, often used in diffuse correlation spectroscopy, underestimates the normalized field autocorrelation function for increasing correlation times.

8.
Opt Express ; 24(18): 20382-99, 2016 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-27607645

RESUMEN

A set of time-domain analytical forward solvers for Raman signals detected from homogeneous diffusive media is presented. The time-domain solvers have been developed for two geometries: the parallelepiped and the finite cylinder. The potential presence of a background fluorescence emission, contaminating the Raman signal, has also been taken into account. All the solvers have been obtained as solutions of the time dependent diffusion equation. The validation of the solvers has been performed by means of comparisons with the results of "gold standard" Monte Carlo simulations. These forward solvers provide an accurate tool to explore the information content encoded in the time-resolved Raman measurements.

9.
Appl Opt ; 55(30): 8500-8505, 2016 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-27828128

RESUMEN

The correlation transport equation (CTE) is the natural generalization of the theory for diffusion correlation spectroscopy and represents a more precise model when dealing with measurements of particle movement in fluids or red blood cell flow in biological tissues. Unfortunately, the CTE is not methodically used due to the complexity of finding solutions. It is shown that actually a very simple modification of the theory/software for the solution of the radiative transport equation allows one to obtain exact solutions of the CTE. The presence of a static background is also taken into account and its influence on the CTE solutions is discussed. The proposed approach permits one to easily work beyond the diffusion regime and potentially for any optical and/or physiological value. The validity of the approach is demonstrated by using "gold standard" Monte Carlo simulations.

10.
Appl Opt ; 55(4): 757-62, 2016 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-26836077

RESUMEN

Diffuse correlation spectroscopy (DCS) is the technique of choice for non-invasive assessments of human bone blood flow. However, DCS classical algorithms are based on the fundamental assumption that the electric field of the light reaching the DCS photodetector is a zero-mean complex Gaussian variable. The non-validity of this hypothesis might produce inaccurate blood flow estimations. It is shown that for the human tibia, the "Gaussian hypothesis" holds for interoptode distances ≥20 mm. This lower boundary seems to depend on the type of investigated tissue.


Asunto(s)
Huesos/fisiología , Electricidad , Probabilidad , Análisis Espectral/métodos , Antebrazo/fisiología , Humanos , Masculino , Tibia/fisiología
11.
J Opt Soc Am A Opt Image Sci Vis ; 32(4): 586-92, 2015 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-26366767

RESUMEN

The classical reciprocity relation of radiative transfer fails for two points placed in regions having different indices of refraction. A modified reciprocity relation that involves the relative refractive index between the two points considered was previously derived for the continuous wave (cw) radiative transfer equation and for the cw diffusion equation (DE) [J. Opt. Soc. Am. A14, 486 (1997)]. In this paper, we extend these findings to the time-dependent DE and we discuss some implications to diffuse optical tomography.


Asunto(s)
Modelos Teóricos , Fenómenos Ópticos , Difusión , Dispersión de Radiación , Factores de Tiempo , Tomografía Óptica
12.
Appl Opt ; 54(9): 2400-6, 2015 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-25968528

RESUMEN

Classical Monte Carlo (MC) simulations for laser-Doppler flowmetry (LDF) often necessitate too long computation times and specialized hardware. This is particularly true for LDF at large interoptode spacing with low absorption coefficients and large anisotropic factors representing real biological tissues. For this reason, a random numbers free "analytical" implementation of the classical MC (MCan) is proposed. The MCan approach allows to obtain noise exempt LDF spectra in a short time and with a simple personal laptop. The proposed MCan holds for a diffusive regime of light propagation and it is practically implemented for a semi-infinite geometry. Its validity is demonstrated by comparisons with the classical MC.


Asunto(s)
Huesos/patología , Flujometría por Láser-Doppler/métodos , Algoritmos , Anisotropía , Simulación por Computador , Computadores , Humanos , Luz , Modelos Estadísticos , Método de Montecarlo , Músculos/patología , Fenómenos Ópticos , Probabilidad , Dispersión de Radiación
13.
Appl Opt ; 54(17): 5320-6, 2015 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-26192830

RESUMEN

It is shown that an analytical noise-free implementation of Monte Carlo simulations [Appl. Opt.54, 2400 (2015).10.1364/AO.54.002400APOPAI1559-128X] for diffuse correlation spectroscopy (DCS) may be successfully used to check the ability of a given DCS model to generate a reliable estimator of tissue blood flow. As an example, four different DCS models often found in the scientific literature are tested on a simulated tissue (semi-infinite geometry) with a Maxwell-Boltzmann probability distribution function for red blood cell speed. It is shown that the random model is the best model for the chosen speed distribution but that (1) some inaccuracies in the DCS model in taking into account red blood cell concentration and (2) some inaccuracies, probably due to a low-order approximation of the DCS model, are still observed. The method can be easily generalized for other speed/flow probability distribution functions of the red blood cells.

14.
Appl Opt ; 53(20): 4580-4, 2014 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-25090080

RESUMEN

Analytical models, describing laser Doppler flowmetry and its derived applications, are based on fundamental assumptions of photon scattering angles. It is shown by means of Monte Carlo simulations that, even in the case these assumptions are correct, the presence of a specific source-detector configuration may bias the shape of the probability density functions describing scattering angle behavior. It is found that these biased shapes are generated by selective filtering of photons induced by a particular source-detector configuration. In some specific cases, this phenomenon might invalidate laser Doppler analytical models.


Asunto(s)
Interpretación Estadística de Datos , Flujometría por Láser-Doppler/métodos , Luz , Iluminación/métodos , Modelos Estadísticos , Dispersión de Radiación , Simulación por Computador , Método de Montecarlo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Distribuciones Estadísticas
15.
Appl Opt ; 53(30): 7017-24, 2014 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-25402789

RESUMEN

A new laser-Doppler flowmeter at large interoptode spacing, based on single-photon counting (single-photon laser-Doppler flowmetry [SP-LDF]) and allowing assessment of blood flow deep in bone tissue, is proposed and implemented. To exploit the advantages of the new SP-LDF hardware, a dedicated simple and efficient time-domain algorithm has been developed. The new algorithm is based on the zero-order moment of the power density spectrum of the ad hoc prefiltered photoelectric current. The SP-LDF has been validated by Monte Carlo simulations, as well as by experimental measurements on a bone tissue phantom for optical flowmeters and on human.


Asunto(s)
Algoritmos , Velocidad del Flujo Sanguíneo/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Flujometría por Láser-Doppler/métodos , Imagen de Perfusión/métodos , Tibia/fisiología , Humanos , Fotones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tibia/irrigación sanguínea
16.
Sci Rep ; 13(1): 9887, 2023 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-37336902

RESUMEN

Monte Carlo (MC) simulations allowing to describe photons propagation in statistical mixtures represent an interest that goes way beyond the domain of optics, and can cover, e.g., nuclear reactor physics, image analysis or life science just to name a few. MC simulations are considered a "gold standard" because they give exact solutions (in the statistical sense), however, in the case of statistical mixtures their implementation is often extremely complex. For this reason, the aim of the present contribution is to propose a new approach that should allow us in the future to simplify the MC approach. This is done through an explanatory example, i.e.; by deriving the 'exact' analytical expression for the probability density function of photons' random steps (single step function, SSF) propagating in a medium represented as a binary (isotropic-Poisson) statistical mixture. The use of the SSF reduces the problem to an 'equivalent' homogeneous medium behaving exactly as the original binary statistical mixture. This will reduce hundreds MC simulations, allowing to obtain one set of wanted parameters, to only one equivalent simple MC simulation. To the best of our knowledge the analytically 'exact' SSF for a binary (isotropic-Poisson) statistical mixture has never been derived before.

17.
J Biomed Opt ; 27(8)2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35445592

RESUMEN

SIGNIFICANCE: Code verification is an unavoidable step prior to using a Monte Carlo (MC) code. Indeed, in biomedical optics, a widespread verification procedure for MC codes is still missing. Analytical benchmarks that can be easily used for the verification of different MC routines offer an important resource. AIM: We aim to provide a two-step verification procedure for MC codes enabling the two main tasks of an MC simulator: (1) the generation of photons' trajectories and (2) the intersections of trajectories with boundaries separating the regions with different optical properties. The proposed method is purely based on elementary analytical benchmarks, therefore, the correctness of an MC code can be assessed with a one-sample t-test. APPROACH: The two-step verification is based on the following two analytical benchmarks: (1) the exact analytical formulas for the statistical moments of the spatial coordinates where the scattering events occur in an infinite medium and (2) the exact invariant solutions of the radiative transfer equation for radiance, fluence rate, and mean path length in media subjected to a Lambertian illumination. RESULTS: We carried out a wide set of comparisons between MC results and the two analytical benchmarks for a wide range of optical properties (from non-scattering to highly scattering media, with different types of scattering functions) in an infinite non-absorbing medium (step 1) and in a non-absorbing slab (step 2). The deviations between MC results and exact analytical values are usually within two standard errors (i.e., t-tests not rejected at a 5% level of significance). The comparisons show that the accuracy of the verification increases with the number of simulated trajectories so that, in principle, an arbitrary accuracy can be obtained. CONCLUSIONS: Given the simplicity of the verification method proposed, we envision that it can be widely used in the field of biomedical optics.


Asunto(s)
Óptica y Fotónica , Fotones , Método de Montecarlo
18.
Adv Exp Med Biol ; 662: 183-9, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20204790

RESUMEN

A new approach to measure muscle oxygen saturation (SmO(2)) using near infrared spectroscopy (NIRS) has been proposed in this paper. This approach exploits the cyclic NIRS signals seen during exercise which are often regarded as "movement artefacts". This new measure, which we term the "cyclic SmO(2)", has the potential to be less affected by the myoglobin which is traditionally believed to be indistinguishable from haemoglobin using NIRS techniques. The cyclic SmO(2) also has fewer assumptions than the conventional SmO(2) measured using time, phase and spatially resolved spectroscopy methods. In a cycling exercise study, NIRS measurements were made over the Vastus lateralis muscle of 11 subjects. In a light exercise protocol, the group mean of the conventional SmO(2) was 51.7 +/- 4.3% and that of the cyclic SmO(2) was 56.0 +/- 3.9%. It was immediately followed by a hard exercise protocol and the group mean of the conventional SmO(2) was reduced to 42.6 +/- 6.1% and that of the cyclic SmO(2) to 48.5 +/- 5.6%. The reduction agrees with the general expectation. The cyclic SmO(2) is a promising new measure of muscle oxygenation.


Asunto(s)
Ejercicio Físico/fisiología , Músculos/metabolismo , Oxígeno/metabolismo , Espectroscopía Infrarroja Corta/métodos , Adulto , Humanos , Masculino , Fenómenos Ópticos
19.
Phys Med Biol ; 54(14): N303-18, 2009 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-19567942

RESUMEN

Monte Carlo (MC) simulations significantly contributed to a better understanding of laser-Doppler flowmetry (LDF). Here it is shown that the data obtained from standard MC simulations can be reinterpreted and used to extract more information such as the photo-electric current (i(t)). This is important because i(t) is the starting point for evaluating any existing or new algorithm to be used in LDF instrumentation. This circumvents the tedious procedure of generating a specific model (often approximated if possible at all) each time a different algorithm is considered. By a series of tutorial examples, the influence of various parameters is investigated, e.g. sampling rate, total acquisition time and dc filtering. These cases also demonstrate the fundamental role played by the photons' random phase in the shaping of the LDF signal. In particular, it is demonstrated by MC simulation that when the number of photon-moving red blood cell interactions is too low, then the Siegert relation that exists between the field and photo-electric current autocorrelation functions does not hold. This is an important point because the validity of the Siegert relation is implicitly admitted in the majority of the classical analytical models for the autocorrelation function in LDF (the classical MC approach does not allow one to study this problem). The proposed method and examples could stimulate new ideas and help the scientific community develop, test and validate new approaches in LDF.


Asunto(s)
Algoritmos , Flujometría por Láser-Doppler/métodos , Modelos Biológicos , Nefelometría y Turbidimetría/métodos , Simulación por Computador , Campos Electromagnéticos , Luz , Método de Montecarlo
20.
Biomed Opt Express ; 8(6): 2990-3004, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-28663921

RESUMEN

The depth sensitivity functions for AC amplitude, phase (PH) and DC intensity signals have been obtained in the frequency domain (where the source amplitude is modulated at radio-frequencies) by making use of analytical solutions of the photon diffusion equation in an infinite slab geometry. Furthermore, solutions for the relative contrast of AC, PH and DC signals when a totally absorbing plane is placed at a fixed depth of the slab have also been obtained. The solutions have been validated by comparisons with gold standard Monte Carlo simulations. The obtained results show that the AC signal, for modulation frequencies < 200 MHz, has a depth sensitivity with similar characteristics to that of the continuous-wave (CW) domain (source modulation frequency of zero). Thus, the depth probed by such a signal can be estimated by using the formula of penetration depth for the CW domain (Sci. Rep.6, 27057 (2016)). However, the PH signal has a different behavior compared to the CW domain, showing a larger depth sensitivity at shallow depths and a less steep relative contrast as a function of depth. These results mark a clear difference in term of depth sensitivity between AC and PH signals, and highlight the complexity of the estimation of the actual depth probed in tissue spectroscopy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA