1.
J Magn Reson Imaging ; 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38485244

RESUMEN

BACKGROUND: Postacute Covid-19 patients commonly present with respiratory symptoms; however, a noninvasive imaging method for quantitative characterization of respiratory patterns is lacking. PURPOSE: To evaluate if quantitative characterization of respiratory pattern on free-breathing higher temporal resolution MRI stratifies patients by cardiopulmonary symptom burden. STUDY TYPE: Prospective analysis of retrospectively acquired data. SUBJECTS: A total of 37 postacute Covid-19 patients (25 male; median [interquartile range (IQR)] age: 58 [42-64] years; median [IQR] days from acute infection: 335 [186-449]). FIELD STRENGTH/SEQUENCE: 0.55 T/two-dimensional coronal true fast imaging with steady-state free precession (trueFISP) at higher temporal resolution. ASSESSMENT: Patients were stratified into three groups based on presence of no (N = 11), 1 (N = 14), or ≥2 (N = 14) cardiopulmonary symptoms, assessed using a standardized symptom inventory within 1 month of MRI. An automated lung postprocessing workflow segmented each lung in each trueFISP image (temporal resolution 0.2 seconds) and respiratory curves were generated. Quantitative parameters were derived including tidal lung area, rates of inspiration and expiration, lung area coefficient of variability (CV), and respiratory incoherence (departure from sinusoidal pattern) were. Pulmonary function tests were recorded if within 1 month of MRI. Qualitative assessment of respiratory pattern and lung opacity was performed by three independent readers with 6, 9, and 23 years of experience. STATISTICAL TESTS: Analysis of variance to assess differences in demographic, clinical, and quantitative MRI parameters among groups; univariable analysis and multinomial logistic regression modeling to determine features predictive of patient symptom status; Akaike information criterion to compare the quality of regression models; Cohen and Fleiss kappa (κ) to quantify inter-reader reliability. Two-sided 5% significance level was used. RESULTS: Tidal area and lung area CV were significantly higher in patients with two or more symptoms than in those with one or no symptoms (area: 15.4 cm2 vs. 12.9 cm2 vs. 12.8 cm2 ; CV: 0.072, 0.067, and 0.058). Respiratory incoherence was significantly higher in patients with two or more symptoms than in those with one or no symptoms (0.05 vs. 0.043 vs. 0.033). There were no significant differences in patient age (P = 0.19), sex (P = 0.88), lung opacity severity (P = 0.48), or pulmonary function tests (P = 0.35-0.97) among groups. Qualitative reader assessment did not distinguish between groups and showed slight inter-reader agreement (κ = 0.05-0.11). DATA CONCLUSION: Quantitative respiratory pattern measures derived from dynamic higher-temporal resolution MRI have potential to stratify patients by symptom burden in a postacute Covid-19 cohort. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 3.

2.
Sensors (Basel) ; 24(12)2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38931494

RESUMEN

Due to limitations in current motion tracking technologies and increasing interest in alternative sensors for motion tracking both inside and outside the MRI system, in this study we share our preliminary experience with three alternative sensors utilizing diverse technologies and interactions with tissue to monitor motion of the body surface, respiratory-related motion of major organs, and non-respiratory motion of deep-seated organs. These consist of (1) a Pilot-Tone RF transmitter combined with deep learning algorithms for tracking liver motion, (2) a single-channel ultrasound transducer with deep learning for monitoring bladder motion, and (3) a 3D Time-of-Flight camera for observing the motion of the anterior torso surface. Additionally, we demonstrate the capability of these sensors to simultaneously capture motion data outside the MRI environment, which is particularly relevant for procedures like radiation therapy, where motion status could be related to previously characterized cyclical anatomical data. Our findings indicate that the ultrasound sensor can track motion in deep-seated organs (bladder) as well as respiratory-related motion. The Time-of-Flight camera offers ease of interpretation and performs well in detecting surface motion (respiration). The Pilot-Tone demonstrates efficacy in tracking bulk respiratory motion and motion of major organs (liver). Simultaneous use of all three sensors could provide complementary motion information outside the MRI bore, providing potential value for motion tracking during position-sensitive treatments such as radiation therapy.


Asunto(s)
Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Respiración , Hígado/diagnóstico por imagen , Hígado/fisiología , Movimiento/fisiología , Vejiga Urinaria/diagnóstico por imagen , Vejiga Urinaria/fisiología , Algoritmos , Aprendizaje Profundo , Movimiento (Física) , Ultrasonografía/métodos
3.
Acta Radiol ; 62(1): 58-66, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32233646

RESUMEN

BACKGROUND: Half-Fourier acquisition single-shot turbo spin-echo (HASTE), continuous radial gradient-echo (GRE), and True FISP allow real-time dynamic assessment of the spine. PURPOSE: To evaluate the feasibility of adding dynamic sequences to routine spine magnetic resonance imaging (MRI) for assessment of spondylolisthesis. MATERIAL AND METHODS: Retrospective review was performed of patients referred for dynamic MRI of the cervical or lumbar spine between January 2017 and 2018 who had flexion-extension radiographs within two months of MRI. Exclusion criteria were: incomplete imaging; spinal hardware; and inability to tolerate dynamic examination. Blinded, independent review by two board-certified musculoskeletal radiologists was performed to assess for spondylolisthesis (>3 mm translation); consensus review of dynamic radiographs served as the gold standard. Cervical spinal cord effacement was assessed. Inter-reader agreement and radiographic concordance was calculated for each sequence. RESULTS: Twenty-one patients were included (8 men, 13 women; mean age 47.9 ± 16.5 years). Five had MRI of the cervical spine and 16 had MRI of the lumbar spine. Mean acquisition time was 18.4 ± 1.7 min with dynamic sequences in the range of 58-77 s. HASTE and True FISP had the highest inter-reader reproducibility (κ = 0.88). Reproducibility was better for the lumbar spine (κ = 0.94) than the cervical spine (κ = 0.28). Sensitivity of sequences for spondylolisthesis was in the range of 68.8%-78.6%. All three sequences had high accuracy levels: ≥90.5% averaged across the cervical and lumbar spine. Cervical cord effacement was observed during dynamic MRI in two cases (100% agreement). CONCLUSION: Real-time dynamic MRI sequences added to spine MRI protocols provide reliable and accurate assessment of cervical and lumbar spine spondylolisthesis during flexion and extension.


Asunto(s)
Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/fisiopatología , Imagen por Resonancia Magnética/métodos , Espondilolistesis/diagnóstico por imagen , Espondilolistesis/fisiopatología , Fenómenos Biomecánicos/fisiología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular/fisiología , Reproducibilidad de los Resultados , Estudios Retrospectivos
4.
J Magn Reson Imaging ; 47(3): 723-728, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28577329

RESUMEN

PURPOSE: To develop and test a deep learning approach named Convolutional Neural Network (CNN) for automated screening of T2 -weighted (T2 WI) liver acquisitions for nondiagnostic images, and compare this automated approach to evaluation by two radiologists. MATERIALS AND METHODS: We evaluated 522 liver magnetic resonance imaging (MRI) exams performed at 1.5T and 3T at our institution between November 2014 and May 2016 for CNN training and validation. The CNN consisted of an input layer, convolutional layer, fully connected layer, and output layer. 351 T2 WI were anonymized for training. Each case was annotated with a label of being diagnostic or nondiagnostic for detecting lesions and assessing liver morphology. Another independently collected 171 cases were sequestered for a blind test. These 171 T2 WI were assessed independently by two radiologists and annotated as being diagnostic or nondiagnostic. These 171 T2 WI were presented to the CNN algorithm and image quality (IQ) output of the algorithm was compared to that of two radiologists. RESULTS: There was concordance in IQ label between Reader 1 and CNN in 79% of cases and between Reader 2 and CNN in 73%. The sensitivity and the specificity of the CNN algorithm in identifying nondiagnostic IQ was 67% and 81% with respect to Reader 1 and 47% and 80% with respect to Reader 2. The negative predictive value of the algorithm for identifying nondiagnostic IQ was 94% and 86% (relative to Readers 1 and 2). CONCLUSION: We demonstrate a CNN algorithm that yields a high negative predictive value when screening for nondiagnostic T2 WI of the liver. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:723-728.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Hepatopatías/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Algoritmos , Aprendizaje Profundo , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Retrospectivos , Sensibilidad y Especificidad
5.
J Magn Reson Imaging ; 48(2): 431-440, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29357200

RESUMEN

BACKGROUND: There is growing interest in detecting cerebro-cerebellar circuits, which requires adequate blood oxygenation level dependent contrast and signal-to-noise ratio (SNR) throughout the brain. Although 7T scanners offer increased SNR, coverage of commercial head coils is currently limited to the cerebrum. PURPOSE: To improve cerebellar functional MRI (fMRI) at 7T with high permittivity material (HPM) pads extending the sensitivity of a commercial coil. STUDY TYPE: Simulations were used to determine HPM pad configuration and assess radiofrequency (RF) safety. In vivo experiments were performed to evaluate RF field distributions and SNR and assess improvements of cerebellar fMRI. SUBJECTS: Eight healthy volunteers enrolled in a prospective motor fMRI study with and without HPM. FIELD STRENGTH/SEQUENCE: Gradient echo (GRE) echo planar imaging for fMRI, turbo FLASH for flip angle mapping, GRE sequence for SNR maps, and T1 -weighted MPRAGE were acquired with and without HPM pads at 7T. ASSESSMENT: Field maps, SNR maps, and anatomical images were evaluated for coverage. Simulation results were used to assess SAR levels of the experiment. Activation data from fMRI experiments were compared with and without HPM pads. STATISTICAL TESTS: fMRI data were analyzed using FEAT FSL for each subject followed by group level analysis using paired t-test of acquisitions with and without HPM. RESULTS: Simulations showed 52% improvement in transmit efficiency in cerebellum with HPM and SAR levels well below recommended limits. Experiments showed 27% improvement in SNR in cerebellum and improvement in coverage on T1 -weighted images. fMRI showed greater cerebellar activation in individual subjects with the HPM pad present (Z > = 4), especially in inferior slices of cerebellum, with 59% average increase in number of activated voxels in the cerebellum. Group-level analysis showed improved functional activation (Z > = 2.3) in cerebellar regions with HPM pads without loss of measured activation elsewhere. DATA CONCLUSION: HPM pads can improve cerebellar fMRI at 7T with a commonly-used head coil without compromising RF safety. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2018;48:431-440.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/instrumentación , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Adulto , Simulación por Computador , Medios de Contraste/química , Diseño de Equipo , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Fantasmas de Imagen , Estudios Prospectivos , Ondas de Radio , Reproducibilidad de los Resultados , Relación Señal-Ruido
6.
AJR Am J Roentgenol ; 210(6): 1309-1316, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29629794

RESUMEN

OBJECTIVE: The purpose of this study was to determine whether adding DWI to conventional MRI of the sacroiliac joints improves the diagnostic performance of MRI readers in the detection of sacroiliitis. MATERIALS AND METHODS: MR images of the sacroiliac joints of 63 patients with lower back pain obtained between January 2016 and December 2016 were analyzed retrospectively. Three readers reviewed the MRI studies for bone marrow edema lesions around the sacroiliac joints as a marker of active sacroiliitis and gave a diagnostic confidence score of 0-4 using MRI without DWI and MRI with DWI in separate sessions. The normalized apparent diffusion coefficient mean (nADCmean) was measured. Clinical and radiologic data using the Assessment of Spondyloarthritis International Society criteria were the reference for the diagnosis of sacroiliitis. Diagnostic performance, confidence scores, and interreader agreement for the MRI methods were compared. The nADCmean values of patients with and those without sacroiliitis were compared. RESULTS: The accuracy, sensitivity, and specificity of MRI without DWI were 68.3%, 69.0%, and 67.6% and for MRI with DWI were 74.6%, 69.0%, and 79.4% (accuracy and sensitivity, p > 0.100; specificity, p = 0.039). The mean confidence score for MRI without DWI was 3.60 and for MRI with DWI was 3.67 (p = 0.270). The kappa coefficient for MRI without DWI was 0.28 and for MRI with DWI was 0.46 (p = 0.041). The nADCmean in patients with sacroiliitis was 3.86 and in patients without sacroiliitis was 1.6 (p ≤ 0.001). The nADCmean AUC was 0.758 (95% CI, 0.67-0.83). CONCLUSION: The addition of DWI to conventional MRI does not significantly improve overall diagnostic performance in terms of accuracy, sensitivity, or confidence in the detection of inflammatory sacroiliitis, but it does have increased specificity and interobserver agreement. ADC threshold values can be used as predictors of sacroiliitis but give no added advantage over MRI with DWI.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Sacroileítis/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
7.
Magn Reson Med ; 78(1): 79-87, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-27454003

RESUMEN

PURPOSE: To develop an accelerated SEMAC metal implant MRI technique (Sparse-SEMAC) with reduced scan time and improved metal distortion correction. METHODS: Sparse-SEMAC jointly exploits the inherent sparsity along the additional phase-encoding dimension and multicoil encoding capabilities to significantly accelerate data acquisition. A prototype pulse sequence with pseudorandom ky -kz undersampling and an inline image reconstruction was developed for integration in clinical studies. Three patients with hip implants were imaged using the proposed Sparse-SEMAC with eight-fold acceleration and compared with the standard-SEMAC technique used in clinical studies (three-fold GRAPPA acceleration). Measurements were performed with SEMAC-encoding steps (SES) = 15 for Sparse-SEMAC and SES = 9 for Standard-SEMAC using high spatial resolution Proton Density (PD) and lower-resolution STIR acquisitions. Two expert musculoskeletal (MSK) radiologists performed a consensus reading to score image-quality parameters. RESULTS: Sparse-SEMAC enables up to eight-fold acceleration of data acquisition that results in two-fold scan time reductions, compared with Standard-SEMAC, with improved metal artifact correction for patients with hip implants without degrading spatial resolution. CONCLUSION: The high acceleration enabled by Sparse-SEMAC would enable clinically feasible examination times with improved correction of metal distortion. Magn Reson Med 78:79-87, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Algoritmos , Artefactos , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Metales , Prótesis e Implantes , Procesamiento de Señales Asistido por Computador , Cadáver , Compresión de Datos/métodos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
J Neuroophthalmol ; 37(2): 187-196, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28459736

RESUMEN

BACKGROUND: Clinical orbital MRI protocols are routinely used to study the optic nerves and exclude compressive lesions, infarctions, or inflammation. However, the small caliber and divergent oblique orientations of the optic nerves make it challenging to characterize them well with conventional MRI, especially since adjacent air-filled bony structures distort the MRI signal and motion is a problem even in cooperative, healthy volunteers. EVIDENCE ACQUISITION: Over the past 3 years we have experimented with multiple novel MRI approaches and sequences to better characterize the optic nerves. The perfect MRI protocol would be quantitative and sensitive to subtle optic nerve pathologic changes, provide high spatial resolution, be rapidly acquired, and resistant to motion degradation. RESULTS: This review provides an update of recent MRI sequence innovations for the optic nerves being currently translated into clinical practice. Methods discussed include rapid MRI with compressed sensing or simultaneous multislice approaches, postprocessing techniques for quantitative T2 mapping or track density imaging, and multiple MRI sequences for measuring diffusion in the optic nerves. CONCLUSIONS: Recently-developed orbit-specific MRI coils, quantitative sequences, and rapid acquisition techniques can improve our future ability to study optic nerve pathologies noninvasively. As advanced MRI becomes more proficient at characterizing the optic nerves, its role in the clinical management of patients should increase.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Nervio Óptico/patología , Neuritis Óptica/diagnóstico , Humanos , Reproducibilidad de los Resultados
9.
Skeletal Radiol ; 46(2): 191-199, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27896400

RESUMEN

OBJECTIVE: To determine whether there is an association between T2/T2* mapping and supraspinatus tendon mechanical properties as assessed by shear-wave ultrasound elastography (SWE). MATERIALS AND METHODS: This HIPAA-compliant prospective pilot study received approval from our hospital's institutional review board. Eight patients (3 males/5 females; age range 44-72 years) and nine shoulders underwent conventional shoulder MRI, T2/T2* mapping on a 3-T scanner, and SWE. Two musculoskeletal radiologists reviewed the MRI examinations in consensus for evidence of supraspinatus tendon pathology, with tear size measured for full-thickness tears. T2/T2* values and ultrasound shear-wave velocities (SWV) were calculated in three corresponding equidistant regions of interest (ROIs) within the insertional 1-2 cm of the supraspinatus tendon (medial, middle, lateral). Pearson correlation coefficients between T2/T2* values and SWV, as well as among T2, T2*, SWV and tear size, were calculated. RESULTS: There was a significant negative correlation between T2* and SWV in the lateral ROI (r = -0.86, p = 0.013) and overall mean ROI (r = -0.90, p = 0.006). There was significant positive correlation between T2 and measures of tear size in the lateral and mean ROIs (r range 0.71-0.77, p range 0.016-0.034). There was significant negative correlation between SWV and tear size in the middle and mean ROIs (r range -0.79--0.68, p range 0.011-0.046). CONCLUSION: Our pilot study demonstrated a potential relationship between T2* values and shear wave velocity values in the supraspinatus tendon, a finding that could lead to an improved, more quantitative evaluation of the rotator cuff tendons.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Imagen por Resonancia Magnética/métodos , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos
10.
Radiology ; 280(2): 585-94, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26982678

RESUMEN

Purpose To develop a three-dimensional breath-hold (BH) magnetic resonance (MR) cholangiopancreatographic protocol with sampling perfection with application-optimized contrast using different flip-angle evolutions (SPACE) acquisition and sparsity-based iterative reconstruction (SPARSE) of prospectively sampled 5% k-space data and to compare the results with conventional respiratory-triggered (RT) acquisition. Materials and Methods This HIPAA-compliant prospective study was institutional review board approved. Twenty-nine patients underwent conventional RT SPACE and BH-accelerated SPACE acquisition with 5% k-space sampling at 3 T. Spatial resolution and other parameters were matched when possible. BH SPACE images were reconstructed by enforcing joint multicoil sparsity in the wavelet domain (SPARSE-SPACE). Two board-certified radiologists independently evaluated BH SPARSE-SPACE and RT SPACE images for image quality parameters in the pancreatic duct and common bile duct by using a five-point scale. The Wilcoxon signed-rank test was used to compare BH SPARSE-SPACE and RT SPACE images. Results Acquisition time for BH SPARSE-SPACE was 20 seconds, which was significantly (P < .001) shorter than that for RT SPACE (mean ± standard deviation, 338.8 sec ± 69.1). Overall image quality scores were higher for BH SPARSE-SPACE than for RT SPACE images for both readers for the proximal, middle, and distal pancreatic duct, but the difference was not statistically significant (P > .05). For reader 1, distal common bile duct scores were significantly higher with BH SPARSE-SPACE acquisition (P = .036). More patients had acceptable or better overall image quality (scores ≥ 3) with BH SPARSE-SPACE than with RT SPACE acquisition, respectively, for the proximal (23 of 29 [79%] vs 22 of 29 [76%]), middle (22 of 29 [76%] vs 18 of 29 [62%]), and distal (20 of 29 [69%] vs 13 of 29 [45%]) pancreatic duct and the proximal (25 of 28 [89%] vs 22 of 28 [79%]) and distal (25 of 28 [89%] vs 24 of 28 [86%]) common bile duct. Conclusion BH SPARSE-SPACE showed similar or superior image quality for the pancreatic and common duct compared with that of RT SPACE despite 17-fold shorter acquisition time. (©) RSNA, 2016.


Asunto(s)
Contencion de la Respiración , Pancreatocolangiografía por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Enfermedades Pancreáticas/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Conductos Biliares/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Conductos Pancreáticos/diagnóstico por imagen , Estudios Prospectivos
11.
Magn Reson Med ; 75(5): 2195-203, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26096947

RESUMEN

PURPOSE: Present a novel method for rapid prediction of temperature in vivo for a series of pulse sequences with differing levels and distributions of specific energy absorption rate (SAR). THEORY AND METHODS: After the temperature response to a brief period of heating is characterized, a rapid estimate of temperature during a series of periods at different heating levels is made using a linear heat equation and impulse-response (IR) concepts. Here the initial characterization and long-term prediction for a complete spine exam are made with the Pennes' bioheat equation where, at first, core body temperature is allowed to increase and local perfusion is not. Then corrections through time allowing variation in local perfusion are introduced. RESULTS: The fast IR-based method predicted maximum temperature increase within 1% of that with a full finite difference simulation, but required less than 3.5% of the computation time. Even higher accelerations are possible depending on the time step size chosen, with loss in temporal resolution. Correction for temperature-dependent perfusion requires negligible additional time and can be adjusted to be more or less conservative than the corresponding finite difference simulation. CONCLUSION: With appropriate methods, it is possible to rapidly predict temperature increase throughout the body for actual MR examinations.


Asunto(s)
Calor/efectos adversos , Imagen por Resonancia Magnética , Columna Vertebral/patología , Algoritmos , Temperatura Corporal , Simulación por Computador , Campos Electromagnéticos , Transferencia de Energía , Humanos , Modelos Estadísticos , Perfusión , Conductividad Térmica , Imagen de Cuerpo Entero
12.
AJR Am J Roentgenol ; 203(4): 883-9, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25247956

RESUMEN

OBJECTIVE: Traditional fat-suppressed T1-weighted spin-echo or turbo spin-echo (TSE) sequences (T1-weighted images) may be degraded by motion and pulsation artifacts in head-and-neck studies. Our purpose is to evaluate the role of a fat-suppressed T1-weighted 3D radial gradient-recalled echo sequence (radial-volumetric interpolated breath-hold examination [VIBE]) in the head and neck as compared with standard contrast-enhanced fat-suppressed T1-weighted images. MATERIALS AND METHODS: We retrospectively evaluated 21 patients (age range, 9-67 years) who underwent head-and-neck MRI at 1.5 T. Both contrast-enhanced radial-VIBE and conventional fat-suppressed TSE contrast-enhanced T1-weighted imaging were performed. Two radiologists evaluated multiple parameters of image quality, graded on a 5-point scale. Mixed-model analysis of variance and interobserver variability assessment were performed. RESULTS: The following parameters were scored as significantly better for the contrast-enhanced radial-VIBE sequence than for conventional contrast-enhanced T1-weighted imaging: overall image quality (p < 0.0001), degree of fat suppression (p = 0.006), mucosal enhancement (p = 0.004), muscle edge clarity (p = 0.049), vessel clarity (p < 0.0001), respiratory motion artifact (p = 0.002), pulsation artifact (p < 0.0001), and lesion edge sharpness (p = 0.004). Interobserver agreement in qualitative evaluation of the two sequences showed fair-to-good agreement for the following variables: overall image quality (intraclass correlation coefficient [ICC], 0.779), degree of fat suppression (ICC, 0.716), mucosal enhancement (ICC, 0.693), muscle edge clarity (ICC, 0.675), respiratory motion artifact (ICC, 0.516), lesion enhancement (ICC, 0.410), and lesion edge sharpness (ICC, 0.538). Excellent agreement was shown for vessel clarity (ICC, 0.846) and pulsation artifact (ICC, 0.808). CONCLUSION: The radial-VIBE sequence is a viable motion-robust improvement on the conventional fat-suppressed T1-weighted sequence.


Asunto(s)
Tejido Adiposo/patología , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Gadolinio , Neoplasias de Cabeza y Cuello/patología , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Adolescente , Adulto , Anciano , Niño , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción , Adulto Joven
13.
AJR Am J Roentgenol ; 200(6): 1378-86, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23701079

RESUMEN

OBJECTIVE: The purpose of this review is to illustrate various applications of gadofosveset trisodium in evaluating abdominal and peripheral vascular disease. The basic properties, technical considerations, and clinical and potential future applications of gadofosveset are described. CONCLUSION: Gadofosveset trisodium facilitates comprehensive high-resolution arterial and venous MR angiography. Because of its prolonged intravascular residence time, gadofosveset trisodium is particularly useful for evaluating venous, dynamic, and functional vascular disease with a single low-dose contrast injection.


Asunto(s)
Abdomen/irrigación sanguínea , Medios de Contraste , Gadolinio , Angiografía por Resonancia Magnética , Compuestos Organometálicos , Enfermedades Vasculares Periféricas/diagnóstico , Humanos
14.
Otol Neurotol ; 44(4): e223-e229, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36806625

RESUMEN

OBJECTIVE: To determine if metal reduction magnetic resonance imaging sequences and changes in implant placement minimize artifact from cochlear implants and improve visualization of intracranial structures. STUDY DESIGN: Cadaveric study. SETTING: Tertiary referral center. PATIENTS: Five cadaveric heads. INTERVENTIONS: Specimens were implanted with Advanced Bionics HiRes Ultra3D devices at nasion-external auditory canal angles of 90, 120, and 160 degrees, and distances from the external auditory canal of 9 or 12 cm. Standard brain/internal auditory canal (IAC) sequences with metal artifact reducing technique were acquired in a 1.5T scanner. MAIN OUTCOME MEASURES: The primary outcome was visibility of 14 intracranial structures graded on a 4-point scale (1, structures <50% visible; 2, >50% visible with some areas nonvisible from artifact; 3, artifact present but adequate for diagnosis; and 4, high quality). Scores were determined by experienced head and neck radiologists and compared with one-way analysis of variance. RESULTS: Imaging sequences included axial 5-mm whole-brain turbo spin echo (TSE) T2 with right to left and anterior to posterior encoding, fluid-attenuation inversion recovery high bandwidth, axial 5-mm whole-brain slice-encoding metal artifact correction (SEMAC), axial IAC constructive interference in steady state, and axial 3-mm T1 IAC with and without fat saturation. T1 IACs in axial and coronal planes were best for ipsilateral structures overall (mean [standard deviation {SD}], 3.8 [0.6] and 3.8 [0.5]). SEMAC (mean [SD], 3.5 [0.8]) was superior to TSE with anterior to posterior encoding (mean [SD], 3.5 [0.9) for ipsilateral cortex, cerebellopontine angle, and brainstem/cerebellum, and equivalent for the inner ear. Constructive interference in steady state and T1 with fat saturation were poor for all ipsilateral structures (mean, 2.8 [ p < 0.01]; mean, 3.1 [ p < 0.01]). The 120 degrees/12 cm position was overall best, although the 120 degrees/9 cm position still afforded visualization of ipsilateral structures; other angles and distances conferred slight advantages for specific structures of interest. CONCLUSIONS: SEMAC and T2 TSE with anterior to posterior encoding sequences provide artifact suppression while retaining excellent image quality. Different placement angles did not confer improvement in visualization, although placement distances provided slight advantages for some structures.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Artefactos , Imanes , Imagen por Resonancia Magnética/métodos , Cadáver
15.
Invest Radiol ; 58(10): 720-729, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37222526

RESUMEN

INTRODUCTION: Prostate cancer diffusion weighted imaging (DWI) MRI is typically performed at high-field strength (3.0 T) in order to overcome low signal-to-noise ratio (SNR). In this study, we demonstrate the feasibility of prostate DWI at low field enabled by random matrix theory (RMT)-based denoising, relying on the MP-PCA algorithm applied during image reconstruction from multiple coils. METHODS: Twenty-one volunteers and 2 prostate cancer patients were imaged with a 6-channel pelvic surface array coil and an 18-channel spine array on a prototype 0.55 T system created by ramping down a commercial magnetic resonance imaging system (1.5 T MAGNETOM Aera Siemens Healthcare) with 45 mT/m gradients and 200 T/m/s slew rate. Diffusion-weighted images were acquired with 4 non-collinear directions, for which b = 50 s/mm 2 was used with 8 averages and b = 1000 s/mm 2 with 40 averages; 2 extra b = 50 s/mm 2 were used as part of the dynamic field correction. Standard and RMT-based reconstructions were applied on DWI over different ranges of averages. Accuracy/precision was evaluated using the apparent diffusion coefficient (ADC), and image quality was evaluated over 5 separate reconstructions by 3 radiologists with a 5-point Likert scale. For the 2 patients, we compare image quality and lesion visibility of the RMT reconstruction versus the standard one on 0.55 T and on clinical 3.0 T. RESULTS: The RMT-based reconstruction in this study reduces the noise floor by a factor of 5.8, thereby alleviating the bias on prostate ADC. Moreover, the precision of the ADC in prostate tissue after RMT increases over a range of 30%-130%, with the increase in both signal-to-noise ratio and precision being more prominent for a low number of averages. Raters found that the images were consistently of moderate to good overall quality (3-4 on the Likert scale). Moreover, they determined that b = 1000 s/mm 2 images from a 1:55-minute scan with the RMT-based reconstruction were on par with the corresponding images from a 14:20-minute scan with standard reconstruction. Prostate cancer was visible on ADC and calculated b = 1500 images even with the abbreviated 1:55-minute scan reconstructed with RMT. CONCLUSIONS: Prostate imaging using DWI is feasible at low field and can be performed more rapidly with noninferior image quality compared with standard reconstruction.


Asunto(s)
Próstata , Neoplasias de la Próstata , Masculino , Humanos , Próstata/diagnóstico por imagen , Próstata/patología , Estudios de Factibilidad , Neoplasias de la Próstata/patología , Imagen de Difusión por Resonancia Magnética/métodos , Relación Señal-Ruido , Reproducibilidad de los Resultados
16.
J Magn Reson Imaging ; 35(4): 963-8, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22147589

RESUMEN

PURPOSE: To evaluate the feasibility of performing single breathhold three-dimensional (3D) thoracic noncontrast MR angiography (NC-MRA) using highly accelerated parallel imaging. MATERIALS AND METHODS: We developed a single breathhold NC MRA pulse sequence using balanced steady state free precession (SSFP) readout and highly accelerated parallel imaging. In 17 subjects, highly accelerated noncontrast MRA was compared against electrocardiogram-triggered contrast-enhanced MRA. Anonymized images were randomized for blinded review by two independent readers for image quality, artifact severity in eight defined vessel segments and aortic dimensions in six standard sites. NC-MRA and CE-MRA were compared in terms of these measures using paired sample t- and Wilcoxon tests. RESULTS: The overall image quality (3.21 ± 0.68 for NC-MRA versus 3.12 ± 0.71 for CE-MRA) and artifact (2.87 ± 1.01 for NC-MRA versus 2.92 ± 0.87 for CE-MRA) scores were not significantly different, but there were significant differences for the great vessel and coronary artery origins. NC-MRA demonstrated significantly lower aortic diameter measurements compared with CE-MRA; however, this difference was not considered clinically relevant (>3 mm difference) for less than 12% of segments, most commonly at the sinotubular junction. Mean total scan time was significantly lower for NC-MRA compared with CE-MRA (18.2 ± 6.0 s versus 28.1 ± 5.4 s, respectively; P < 0.05). CONCLUSION: Single breathhold NC-MRA is feasible and can be a useful alternative for evaluation and follow-up of thoracic aortic diseases.


Asunto(s)
Aorta/anatomía & histología , Aumento de la Imagen/instrumentación , Angiografía por Resonancia Magnética/instrumentación , Mecánica Respiratoria , Tórax/anatomía & histología , Tórax/irrigación sanguínea , Transductores , Adulto , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
17.
Invest Radiol ; 57(8): 517-526, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35239614

RESUMEN

OBJECTIVES: Despite significant progress, artifact-free visualization of the bone and soft tissues around hip arthroplasty implants remains an unmet clinical need. New-generation low-field magnetic resonance imaging (MRI) systems now include slice encoding for metal artifact correction (SEMAC), which may result in smaller metallic artifacts and better image quality than standard-of-care 1.5 T MRI. This study aims to assess the feasibility of SEMAC on a new-generation 0.55 T system, optimize the pulse protocol parameters, and compare the results with those of a standard-of-care 1.5 T MRI. MATERIALS AND METHODS: Titanium (Ti) and cobalt-chromium total hip arthroplasty implants embedded in a tissue-mimicking American Society for Testing and Materials gel phantom were evaluated using turbo spin echo, view angle tilting (VAT), and combined VAT and SEMAC (VAT + SEMAC) pulse sequences. To refine an MRI protocol at 0.55 T, the type of metal artifact reduction techniques and the effect of various pulse sequence parameters on metal artifacts were assessed through qualitative ranking of the images by 3 expert readers while taking measured spatial resolution, signal-to-noise ratios, and acquisition times into consideration. Signal-to-noise ratio efficiency and artifact size of the optimized 0.55 T protocols were compared with the 1.5 T standard and compressed-sensing SEMAC sequences. RESULTS: Overall, the VAT + SEMAC sequence with at least 6 SEMAC encoding steps for Ti and 9 for cobalt-chromium implants was ranked higher than other sequences for metal reduction ( P < 0.05). Additional SEMAC encoding partitions did not result in further metal artifact reductions. Permitting minimal residual artifacts, low magnetic susceptibility Ti constructs may be sufficiently imaged with optimized turbo spin echo sequences obviating the need for SEMAC. In cross-platform comparison, 0.55 T acquisitions using the optimized protocols are associated with 45% to 64% smaller artifacts than 1.5 T VAT + SEMAC and VAT + compressed-sensing/SEMAC protocols at the expense of a 17% to 28% reduction in signal-to-noise ratio efficiency. B 1 -related artifacts are invariably smaller at 0.55 T than 1.5 T; however, artifacts related to B 0 distortion, although frequently smaller, may appear as signal pileups at 0.55 T. CONCLUSIONS: Our results suggest that new-generation low-field SEMAC MRI reduces metal artifacts around hip arthroplasty implants to better advantage than current 1.5 T MRI standard of care. While the appearance of B 0 -related artifacts changes, reduction in B 1 -related artifacts plays a major role in the overall benefit of 0.55 T.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artefactos , Cromo , Cobalto , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Titanio
18.
Eur J Radiol ; 156: 110515, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36099832

RESUMEN

PURPOSE: To evaluate detection and characterization of groundglass and fibrosis-like opacities imaged by non-contrast 0.55 Tesla MRI, and versus clinically-acquired chest CT images, in a cohort of post-Covid patients. MATERIALS AND METHODS: 64 individuals (26 women, mean age 53 ± 14 years, range 19-85) with history of Covid-19 pneumonia were recruited through a survivorship registry, with 106 non-contrast low-field 0.55 T cardiopulmonary MRI exams acquired from 9/8/2020-9/28/2021. MRI exams were obtained at an average interval of 9.5 ± 4.5 months from initial symptom report (range 1-18 months). Of these, 20 participants with 22 MRI exams had corresponding clinically-acquired CT chest imaging obtained within 30 days of MRI (average interval 18 ± 9 days, range 0-30). MR and CT images were reviewed and scored by two thoracic radiologists, for presence and extent of lung opacity by quadrant, opacity distribution, and presence versus absence of fibrosis-like subpleural reticulation and subpleural lines. Scoring was performed for each of four lung quadrants: right upper and middle lobe, right lower lobe, left upper lobe and lingula, and left lower lobe. Agreement between readers and modalities was assessed with simple and linear weighted Cohen's kappa (k) coefficients. RESULTS: Inter-reader concordance on CT for opacity presence, opacity extent, opacity distribution, and presence of subpleural lines and reticulation was 99%, 78%, 97%, 99%, and 94% (k 0.96, 0.86, 0.94, 0.97, 0.89), respectively. Inter-reader concordance on MR, among all 106 exams, for opacity presence, opacity extent, opacity distribution, and presence of subpleural lines and reticulation was 85%, 48%, 70%, 86%, and 76% (k 0.57, 0.32, 0.46, 0.47, 0.37), respectively. Inter-modality agreement between CT and MRI for opacity presence, opacity extent, opacity distribution, and presence subpleural lines and reticulation was 86%, 52%, 79%, 93%, and 76% (k 0.43, 0.63, 0.65, 0.80, 0.52). CONCLUSION: Low-field 0.55 T non-contrast MRI demonstrates fair to moderate inter-reader concordance, and moderate to substantial inter-modality agreement with CT, for detection and characterization of groundglass and fibrosis-like opacities.


Asunto(s)
COVID-19 , Humanos , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Pulmón/diagnóstico por imagen , Fibrosis
19.
Clin Imaging ; 83: 177-183, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35092926

RESUMEN

OBJECTIVE: Texture features are proposed for classification and prognostication, with lacking information about variability. We assessed 3 T liver MRI feature variability. METHODS: Five volunteers underwent standard 3 T MRI, and repeated with identical and altered parameters. Two readers placed regions of interest using 3DSlicer. Repeatability (between standard and repeat scan), robustness (between standard and parameter changed scan), and reproducibility (two reader variation) were computed using coefficient of variation (CV). RESULTS: 67%, 49%, and 61% of features had good-to-excellent (CV ≤ 10%) repeatability on ADC, T1, and T2, respectively, least frequently for first order (19-35%). 22%, 19%, and 21% of features had good-to-excellent robustness on ADC, T1, and T2, respectively. 52%, 35%, and 25% of feature measurements had good-to-excellent inter-reader reproducibility on ADC, T1, and T2, respectively, with highest good-to-excellent reproducibility for first order features on ADC/T1. CONCLUSION: We demonstrated large variations in texture features on 3 T liver MRI. Further study should evaluate methods to reduce variability.


Asunto(s)
Hígado , Imagen por Resonancia Magnética , Humanos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados
20.
Sci Rep ; 12(1): 15010, 2022 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-36056131

RESUMEN

Flexible radiofrequency coils for magnetic resonance imaging (MRI) have garnered attention in research and industrial communities because they provide improved accessibility and performance and can accommodate a range of anatomic postures. Most recent flexible coil developments involve customized conductors or substrate materials and/or target applications at 3 T or above. In contrast, we set out to design a flexible coil based on an off-the-shelf conductor that is suitable for operation at 0.55 T (23.55 MHz). Signal-to-noise ratio (SNR) degradation can occur in such an environment because the resistance of the coil conductor can be significant with respect to the sample. We found that resonating a commercially available RG-223 coaxial cable shield with a lumped capacitor while the inner conductor remained electrically floating gave rise to a highly effective "cable coil." A 10-cm diameter cable coil was flexible enough to wrap around the knee, an application that can benefit from flexible coils, and had similar conductor loss and SNR as a standard-of-reference rigid copper coil. A two-channel cable coil array also provided good SNR robustness against geometric variability, outperforming a two-channel coaxial coil array by 26 and 16% when the elements were overlapped by 20-40% or gapped by 30-50%, respectively. A 6-channel cable coil array was constructed for 0.55 T knee imaging. Incidental cartilage and bone pathologies were clearly delineated in T1- and T2-weighted turbo spin echo images acquired in 3-4 min with the proposed coil, suggesting that clinical quality knee imaging is feasible in an acceptable examination timeframe. Correcting for T1, the SNR measured with the cable coil was approximately threefold lower than that measured with a 1.5 T state-of-the-art 18-channel coil, which is expected given the threefold difference in main magnetic field strength. This result suggests that the 0.55 T cable coil conductor loss does not deleteriously impact SNR, which might be anticipated at low field.


Asunto(s)
Articulación de la Rodilla , Imagen por Resonancia Magnética , Diseño de Equipo , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Ondas de Radio , Relación Señal-Ruido