Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Nutr Metab Cardiovasc Dis ; 33(3): 631-639, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36670006

RESUMEN

BACKGROUND AND AIMS: Intensive glycemic control minimizes the risk of micro- and macrovascular complications in patients with type 1 diabetes (T1D). We report glycemic control in Italian participants (age groups: 26-44, 45-64, and ≥65 years) of the global SAGE study. METHODS AND RESULTS: The primary endpoint was proportion of participants who achieved an HbA1c <7% in predefined age groups. In the 523 patients with T1D, mean age was 44.6 years and mean body mass index (BMI) was 25 kg/m2. Mean HbA1c was 7.5% and 29.4% had HbA1c <7.0%, with the highest percentage in those 26-45 years (31.7%) and the lowest in those ≥65 years (20%). Altogether, 22.9% of patients achieved their physician-established individualized HbA1c target. Most patients had ≥1 symptomatic hypoglycemic episode in the previous 3 months (≤70 mg/dL 82.5%; ≤54 mg/dL 61%). Severe hypo- and hyperglycemia were experienced by 16.3% and 12% of patients, of which 7.1 and 9.5%, respectively, required hospitalization/emergency visits. More patients achieved HbA1c <7% with CSII (30%) than with multiple daily insulin injections (27.9%). In multivariate analysis, BMI (OR 0.94, 95% CI 0.89-0.99, p = 0.032) and adherence to diet (OR 0.36, 95% CI 0.18-0.70, p = 0.0028) were significantly associated with HbA1c <7.0%. CONCLUSIONS: Glycemic control can be considered good in the Italian SAGE cohort, especially in younger patients, who more frequently use pumps/continuous glucose monitoring. Greater patient education and use of technology may further support this achievement. Patients should be encouraged to maintain a low BMI and adhere to their diet.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Hemoglobina Glucada , Control Glucémico/efectos adversos , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Italia/epidemiología , Persona de Mediana Edad , Anciano
2.
J Endocrinol Invest ; 45(6): 1181-1188, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35103951

RESUMEN

AIMS: Post-prandial hyperglycemia remains an unmet need in the management of type 1 diabetes (T1D). In randomized trials, faster insulin aspart (FIA) showed modest but significant reductions of glycemic spikes after meals. Whether such benefit is evident in routine clinical practice is unclear. METHODS: We analyzed data of patients with T1D at the time they switched from a prior bolus insulin to FIA and at the first available follow-up. The primary endpoint was the change in the time spent in hyperglycemia > 250 mg/dl during daytime from flash glucose monitoring (FGM). Secondary outcomes included the change in HbA1c, body weight, insulin dose and other FGM metrics. RESULTS: We included 117 patients with T1D on multiple daily injections who switched to FIA, 57 of whom had data from FGM. Patients were 41-year-old, 51.3% men, with 19.3 years diabetes duration and a baseline HbA1c of 7.7% (60 mmol/mol). Mean observation time was 4.3 months. After switching to FIA, HbA1c declined by 0.1% (1 mmol/mol) only in patients with baseline HbA1c > 7.0% (53 mmol/mol). Time spent in hyperglycemia > 250 mg/dl during daytime was significantly reduced from 14.8 to 11.9% (p = 0.006). Time in range improved from 48.3 to 51.0% (p = 0.028). Results were consistent across various patient characteristics. CONCLUSIONS: Under routine care, patients with T1D who switched to FIA experienced a reduction in the time spent in hyperglycemia > 250 mg/dl during daytime and an increase in time in range. These improvements may be due to better control of post-prandial hyperglycemia, as observed in trials.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hiperglucemia , Adulto , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Hemoglobina Glucada/análisis , Control Glucémico , Humanos , Hiperglucemia/inducido químicamente , Hiperglucemia/tratamiento farmacológico , Hiperglucemia/prevención & control , Hipoglucemiantes , Insulina , Insulina Aspart/uso terapéutico , Masculino
3.
J Endocrinol Invest ; 45(1): 115-124, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34196924

RESUMEN

AIM: To compare accuracy, efficacy and acceptance of implantable and transcutaneous continuous glucose monitoring (CGM) systems. METHODS: In a randomized crossover trial we compared 12 weeks with Eversense implantable sensor (EVS) and 12 weeks with Dexcom G5 transcutaneous sensor (DG5) in terms of accuracy, evaluated as Mean Absolute Relative Difference (MARD) vs capillary glucose (SMBG), time of CGM use, adverse events, efficacy (as HbA1c, time in range, time above and below range) and psychological outcomes evaluated with Diabetes Treatment Satisfaction Questionnaire (DTSQ), Glucose Monitoring Satisfaction Survey (GMSS), Hypoglycemia Fear Survey (HFS2), Diabetes Distress Scale (DDS). RESULTS: 16 subjects (13 males, 48.8 ± 10.1 years, HbA1c 55.8 ± 7.9 mmol/mol, mean ± SD) completed the study. DG5 was used more than EVS [percentage of use 95.7 ± 3.6% vs 93.5 ± 4.3% (p = 0.02)]. MARD was better with EVS (12.2 ± 11.5% vs. 13.1 ± 14.7%, p< 0.001). No differences were found in HbA1c. While using EVS time spent in range increased and time spent in hyperglycemia decreased, but these data were not confirmed by analysis of retrofitted data based on SMBG values. EVS reduced perceived distress, without significant changes in other psychological outcomes. CONCLUSIONS: CGM features may affect glycemic control and device acceptance.


Asunto(s)
Diabetes Mellitus Tipo 1/sangre , Control Glucémico/instrumentación , Aceptación de la Atención de Salud , Adulto , Automonitorización de la Glucosa Sanguínea/efectos adversos , Automonitorización de la Glucosa Sanguínea/instrumentación , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Femenino , Hemoglobina Glucada/análisis , Hemoglobina Glucada/metabolismo , Control Glucémico/efectos adversos , Humanos , Implantes Experimentales/efectos adversos , Insulina/administración & dosificación , Sistemas de Infusión de Insulina/efectos adversos , Italia , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
4.
J Endocrinol Invest ; 44(1): 119-126, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32367464

RESUMEN

BACKGROUND AND PURPOSE: Diabetes reduces the levels of hematopoietic stem/progenitor cells (HSPCs), which can contribute to organ and tissue homeostasis. Among patients with diabetes, lower HSPC levels predict the development or worsening of micro- and macro-angiopathy. High glucose variability is also associated with diabetic complications and we have previously shown that acute hypoglycaemia can stimulate stem/progenitor cells. Thus, we evaluated the relationship between glucose variability or time in hypoglycaemia and HSPCs in patients with type 1 diabetes (T1D). METHODS: Patients with T1D were compared to healthy subjects. HSPCs (CD34+, CD133+, CD34+CD133+, CD34 + CD45dim) were quantified by flow cytometry. Using flash glucose monitoring system for 90 days, we calculated several measures of glucose variability and time in hypoglycaemia. RESULTS: Forty-four patients with T1D and 44 healthy subjects were enrolled. Compared to healthy controls, T1D patients had significantly lower levels of HSPCs and duration of diabetes was inversely correlated with HSPC levels. Significant direct correlations were found between HSPC levels and the coefficient of variation of glucose levels or time in hypoglycaemia, which were stronger in patients with short-term than in those with long-standing diabetes. CONCLUSION: This study confirms the pauperization of HSPCs in T1D patients and demonstrates a potential HSPC-stimulatory effect of hypoglycaemia, which mitigates with long-lasting diabetes. These data are consistent with a model whereby disease chronicity progressively blunts the release of HSPCs in response to adrenergic triggers, like hypoglycaemic events.


Asunto(s)
Células de la Médula Ósea/patología , Diabetes Mellitus Tipo 1/fisiopatología , Glucosa/metabolismo , Células Madre Hematopoyéticas/patología , Células de la Médula Ósea/efectos de los fármacos , Células de la Médula Ósea/metabolismo , Estudios de Casos y Controles , Células Cultivadas , Femenino , Estudios de Seguimiento , Glucosa/administración & dosificación , Células Madre Hematopoyéticas/efectos de los fármacos , Células Madre Hematopoyéticas/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Pronóstico
5.
Nutr Metab Cardiovasc Dis ; 29(5): 421-431, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30952574

RESUMEN

Until recently, in Italy, the use of continuous glucose monitoring (CGM) systems has been limited, but is now rapidly increasing, including the so-called real-time CGM (rtCGM) and the intermittently viewed CGM (iCGM), also called Flash Glucose Monitoring (FGM). These technologies overcome many of the limitations of self-monitoring of blood glucose (SMBG) by fingerprick and allow to go beyond HbA1c to check glucose control in diabetes. However, standardized protocols for applying and interpreting rtCGM and FGM data are lacking. In this paper, we delineate a consensus amongst Italian diabetes physicians on the attributes of rtCGM and FGM technologies, and introduce a consistent approach for their use by Italian healthcare professionals. Most experts consider rtCGM and FGM as two separate categories of interstitial subcutaneous fluid (ISF) sensing technologies, and see them as superior to SMBG. Furthermore, there is strong consensus that rtCGM and FGM reduce hypoglycemia risk, increase the amount of time in the target glucose range and augment treatment satisfaction. However, there is still no agreement on the indication of the FGM for subjects who suffer asymptomatic hypoglycemia. Consensus on the role of education in initiating and optimizing use of rtCGM/FGM and about the interpretation of glucose trends was near unanimous, whereas no consensus was reached on the statement that there are no disadvantages/risks of rtCGM/FGM. Some issues remain in rtCGM/FGM management: a) risk of excessive correction of high or low glucose; b) risk of alert fatigue leading to alert silencing or rtCGM termination; c) allergic reaction to the adhesive keeping rtCGM or FGM sensors in place. The panel almost unanimously agreed that sensor accuracy depends on multiple variables, that alarm setting should be individualized, and that global glycemic profile represent an useful tool in interpreting glucose data. More clinical studies and a wider use of these devices will increase the efficacy and effectiveness of continuous glucose monitoring in Italy.


Asunto(s)
Técnicas Biosensibles/instrumentación , Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/metabolismo , Diabetes Mellitus/diagnóstico , Líquido Extracelular/metabolismo , Dispositivos Electrónicos Vestibles , Biomarcadores/sangre , Glucemia/efectos de los fármacos , Consenso , Técnica Delphi , Diabetes Mellitus/sangre , Diabetes Mellitus/tratamiento farmacológico , Diseño de Equipo , Hemoglobina Glucada/metabolismo , Humanos , Hipoglucemiantes/uso terapéutico , Italia , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo , Resultado del Tratamiento
6.
J Endocrinol Invest ; 42(9): 1099-1107, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30847862

RESUMEN

PURPOSE: In patients with type 1 diabetes (T1D), the prevalence of non-alcoholic fatty liver disease (NAFLD) ranges from 10 to 53% and contrasting evidence suggests that vitamin D deficiency may favor liver fat accumulation. Here, we investigated the association between vitamin D status and NAFLD in adults with T1D. METHODS: 220 consecutive adult T1D patients on multiple daily injections or continuous subcutaneous insulin infusion and not taking calcium or vitamin D supplements were included. Patient characteristics, 25(OH)D serum levels, and metabolic parameters were analyzed. Vitamin D status was defined as sufficiency ( ≥ 75 nmol/L; 30 ng/ml), insufficiency (50-75 nmol/L; 20-30 ng/ml), or deficiency ( < 50 nmol/L; 20 ng/ml). NAFLD was diagnosed at ultrasound examination and graded 0-3. RESULTS: NAFLD was present in 57 patients (29.5%): 51 grade 1, 5 grade 2, and 1 grade 3. Median 25(OH)D levels were 53 nmol/L (IQR 38-70) in patients with NAFLD and 50 nmol/L (34-69) in patients without (p = 0.46). At multivariable analysis, NAFLD was not associated with 25(OH)D levels (p = 0.42) or vitamin D deficiency (p = 0.55), while BMI (OR 1.16, 95% CI 1.07-1.27) and serum triglycerides (OR 1.02, 95% CI 1.01-1.03) were independently associated with NAFLD. CONCLUSIONS: Vitamin D status appears to have no link with low-grade NAFLD in patients with type 1 diabetes.


Asunto(s)
Biomarcadores/sangre , Diabetes Mellitus Tipo 1/fisiopatología , Enfermedad del Hígado Graso no Alcohólico/sangre , Enfermedad del Hígado Graso no Alcohólico/epidemiología , Deficiencia de Vitamina D/complicaciones , Vitamina D/sangre , Vitaminas/sangre , Adolescente , Adulto , Estudios Transversales , Femenino , Estudios de Seguimiento , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/etiología , Prevalencia , Pronóstico , Estudios Prospectivos , Adulto Joven
7.
Nutr Metab Cardiovasc Dis ; 28(2): 180-186, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29258716

RESUMEN

BACKGROUND AND AIMS: This study compared the accuracy of the FreeStyle Libre (Abbott, Alameda, CA) and Dexcom G4 Platinum (DG4P, Dexcom, San Diego, CA) CGM sensors. METHODS AND RESULTS: Twenty-two adults with type 1 diabetes wore the two sensors simultaneously for 2 weeks. Libre was used according to manufacturer-specified lifetime (MSL); DG4P was used 7 days beyond MSL. At a clinical research center (CRC), subjects were randomized to receive the same breakfast with standard insulin bolus (standard) or a delayed and increased (delayed & increased) bolus to induce large glucose swings during weeks 1 and 2; venous glucose was checked every 5-15 min for 6 h. Subjects performed ≥4 reference fingersticks/day at home. Accuracy was assessed by differences in mean absolute relative difference (%MARD) in glucose levels compared with fingerstick test (home use) and YSI reference (CRC). During home-stay the Libre MARD was 13.7 ± 3.6% and the DG4P MARD 12.9 ± 2.5% (difference not significant [NS]). With both systems MARD increased during hypoglycaemia and decreased during hyperglycaemia, without significant difference between sensors. In the euglycaemic range MARD was smaller with DG4P [12.0 ± 2.4% vs 14.0 ± 3.6%, p = 0.026]. MARD increased in both sensors following delayed & increased vs. standard bolus (Libre: 14.9 ± 5.5% vs. 10.9 ± 4.1%, p = 0.008; DG4P: 18.1 ± 8.1% vs. 13.1 ± 4.6%, p = 0.026); between-sensor differences were not significant (p = 0.062). Libre was more accurate during moderate and rapid glucose changes. CONCLUSIONS: DG4P and Libre performed similarly up to 7 days beyond DG4P MSL. Both sensors performed less well during hypoglycaemia but Libre was more accurate during glucose swings. TRIAL REGISTRATION: The study was registered in ClinicalTrials.gov (NCT02734745) April 12, 2016.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/diagnóstico , Adulto , Biomarcadores/sangre , Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diseño de Equipo , Femenino , Humanos , Hipoglucemia/sangre , Hipoglucemia/inducido químicamente , Hipoglucemia/diagnóstico , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Insulina/administración & dosificación , Insulina/efectos adversos , Italia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
8.
Diabet Med ; 34(5): 691-697, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28145047

RESUMEN

AIM: To assess the influence of health locus of control and fear of hypoglycaemia on metabolic control and treatment satisfaction in people with Type 1 diabetes mellitus on continuous subcutaneous insulin infusion. METHODS: People with Type 1 diabetes on continuous subcutaneous insulin infusion for at least 1 year, sub-classified as an 'acceptable glucose control' group [HbA1c ≤ 58 mmol/mol (7.5%)] and a 'suboptimum glucose control' group [HbA1c > 58 mmol/mol (7.5%)], were consecutively enrolled in a multicentre cross-sectional study. Questionnaires were administered to assess health locus of control [Multidimensional Health Locus of Control (MHLC) scale, with internal and external subscales], fear of hypoglycaemia [Hypoglycaemia Fear Survey II (HFS-II)] and treatment satisfaction [Diabetes Treatment Satisfaction Questionnaire (DTSQ)]. RESULTS: We enrolled 214 participants (mean ± sd age 43.4 ± 12.1 years). The suboptimum glucose control group (n = 127) had lower mean ± sd internal MHLC and DTSQ scores than the acceptable glucose control group (19.6 ± 5.2 vs 21.0 ± 5.0, P = 0.04 and 28.8 ± 4.8 vs 30.9 ± 4.5, P < 0.001). HFS-II scores did not differ between the two groups. Internal MHLC score was negatively associated with HbA1c (r = -0.15, P < 0.05) and positively associated with the number of mild and severe hypoglycaemic episodes (r = 0.16, P < 0.05 and r = 0.18, P < 0.001, respectively) and with DTSQ score (r = 0.17, P < 0.05). HFS-II score was negatively associated with DTSQ score (r = -0.18, P < 0.05) and positively with number of severe hypoglycaemic episodes (r = 0.16, P < 0.5). CONCLUSIONS: In adults with Type 1 diabetes receiving continuous subcutaneous insulin infusion, high internal locus represents the most important locus of control pattern for achieving good metabolic control.


Asunto(s)
Glucemia/metabolismo , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Miedo/fisiología , Hipoglucemia/psicología , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Control Interno-Externo , Satisfacción Personal , Adulto , Glucemia/efectos de los fármacos , Estudios Transversales , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/psicología , Miedo/psicología , Femenino , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Insulina/efectos adversos , Sistemas de Infusión de Insulina/psicología , Masculino , Persona de Mediana Edad , Autocuidado
9.
Diabet Med ; 34(2): 262-271, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27696520

RESUMEN

AIM: To assess the impact on fear of hypoglycaemia and treatment satisfaction with an artificial pancreas system used for 2 consecutive months, as well as participant acceptance of the artificial pancreas system. METHODS: In a randomized crossover trial patient-related outcomes associated with an evening-and-night artificial pancreas and sensor-augmented pump therapy were compared. Both intervention periods lasted 8 weeks. The artificial pancreas acceptance questionnaire (range 0-90, higher scores better), Hypoglycaemia Fear Survey II (range 0-72, higher scores worse) and Diabetes Treatment Satisfaction Questionnaire (range 0-36, higher scores better) were completed by 32 participants. Semi-structured interviews were conducted after study completion in a subset of six participants. Outcomes were compared using a repeated-measures anova model or paired t-test when appropriate. RESULTS: The total artificial pancreas acceptance questionnaire score at the end of the artificial pancreas period was 69.1 (sd 14.7; 95% CI 63.5, 74.7), indicating a positive attitude towards the artificial pancreas. No significant differences were found among the scores at baseline, end of sensor-augmented pump therapy period or end of the artificial pancreas period with regard to fear of hypoglycaemia [28.2 (sd 17.5), 23.5 (sd 16.6) and 23.5 (sd 16.7), respectively; P = 0.099] or diabetes treatment satisfaction [29.0 (sd 3.9), 28.2 (sd 5.2) and 28.0 (sd 7.1), respectively; P = 0.43]. Themes frequently mentioned in the interviews were 'positive effects at work', 'improved blood glucose', 'fewer worries about blood glucose', but also 'frequent alarms', 'technological issues' and 'demand for an all-in-one device'. CONCLUSIONS: The psychological outcomes of artificial pancreas and sensor-augmented pump therapy were similar. Current artificial pancreas technology is promising but user concerns should be taken into account to ensure utility of these systems.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Miedo/psicología , Hipoglucemia/psicología , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Páncreas Artificial , Satisfacción del Paciente , Adulto , Glucemia/metabolismo , Estudios Cruzados , Diabetes Mellitus Tipo 1/metabolismo , Femenino , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios
10.
Nutr Metab Cardiovasc Dis ; 26(12): 1112-1119, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27618501

RESUMEN

BACKGROUND AND AIMS: Degludec is an ultralong-acting insulin analogue with a flat and reproducible pharmacodynamic profile. As some patients with type 1 diabetes (T1D) fail to achieve 24-h coverage with glargine or detemir despite twice-daily injections, we studied the effect of switching T1D patients from twice-daily glargine or detemir to degludec. METHODS AND RESULTS: In this prospective observational study, T1D patients on twice-daily glargine or detemir were enrolled. At baseline and 12 weeks after switching to degludec, we recorded HbA1c, insulin dose, 30-day blood glucose self monitoring (SMBG) or 14-day continuous glucose monitoring (CGM), treatment satisfaction (DTSQ), fear of hypoglycemia (FHS). We included 29 patients (mean age 34 ± 11 years; diabetes duration 18 ± 10 years). After switching to degludec, HbA1c decreased from 7.9 ± 0.6% (63 ± 6 mmol/mol) to 7.7 ± 0.6% (61 ± 6 mmol/mol; p = 0.028). SMBG showed significant reductions in the percent and number of blood glucose values <70 mg/dl and in the low blood glucose index (LBGI) during nighttime. CGM showed a significant reduction of time spent in hypoglycemia, an increase in daytime spent in target 70-180 mg/dl, and a reduction in glucose variability. Total insulin dose declined by 17% (p < 0.001), with 24% reduction in basal and 10% reduction in prandial insulin. DTSQ and FHS significantly improved. CONCLUSION: Switching from twice-daily glargine or detemir to once daily degludec improved HbA1c, glucose profile, hypoglycemia risk and treatment satisfaction, while insulin doses decreased. ClinicalTrials.govNCT02360254.


Asunto(s)
Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Sustitución de Medicamentos , Hipoglucemiantes/administración & dosificación , Insulina Detemir/administración & dosificación , Insulina Glargina/administración & dosificación , Insulina de Acción Prolongada/administración & dosificación , Adulto , Biomarcadores/sangre , Glucemia/metabolismo , Ritmo Circadiano , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/diagnóstico , Esquema de Medicación , Femenino , Humanos , Hipoglucemia/sangre , Hipoglucemia/inducido químicamente , Hipoglucemiantes/efectos adversos , Insulina Detemir/efectos adversos , Insulina Glargina/efectos adversos , Insulina de Acción Prolongada/efectos adversos , Italia , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
11.
Diabetes Obes Metab ; 17(4): 343-9, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25132320

RESUMEN

AIMS: To assess the accuracy and reliability of the two most widely used continuous glucose monitoring (CGM) systems. METHODS: We studied the Dexcom®G4 Platinum (DG4P; Dexcom, San Diego, CA, USA) and Medtronic Paradigm Veo Enlite system (ENL; Medtronic, Northridge, CA, USA) CGM systems, in 24 patients with type 1 diabetes. The CGM systems were tested during 6-day home use and a nested 6-h clinical research centre (CRC) visit. During the CRC visit, frequent venous blood glucose samples were used as reference while patients received a meal with an increased insulin bolus to induce an aggravated postprandial glucose nadir. At home, patients performed at least six reference capillary blood measurements per day. A Wilcoxon signed-rank test was performed using all data points ≥15 min apart. RESULTS: The overall mean absolute relative difference (MARD) value [standard deviation (s.d.)] measured at the CRC was 13.6 (11.0)% for the DG4P and 16.6 (13.5)% for the ENL [p < 0.0002, confidence interval of difference (CI Δ) 1.7-4.3%, n = 530]. The overall MARD assessed at home was 12.2 (12.0)% for the DG4P and 19.9 (20.5)% for the ENL (p < 0.0001, CI Δ = 5.8-8.7%, n = 839). During the CRC visit, the MARD in the hypoglycaemic range [≤3.9 mmol/l (70 mg/dl)], was 17.6 (12.2)% for the DG4P and 24.6 (18.8)% for the ENL (p = 0.005, CI Δ 3.1-10.7%, n = 117). Both sensors showed higher MARD values during hypoglycaemia than during euglycaemia [3.9-10 mmol/l (70-180 mg/dl)]: for the DG4P 17.6 versus 13.0% and for the ENL 24.6 versus 14.2%. CONCLUSIONS: During circumstances of intended use, including both a CRC and home phase, the ENL was noticeably less accurate than the DG4P sensor. Both sensors showed lower accuracy in the hypoglycaemic range. The DG4P was less affected by this negative effect of hypoglycaemia on sensor accuracy than was the ENL.


Asunto(s)
Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Hiperglucemia/diagnóstico , Hipoglucemia/diagnóstico , Monitoreo Ambulatorio/instrumentación , Actividades Cotidianas , Adulto , Austria , Investigación Biomédica/instrumentación , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Francia , Humanos , Hiperglucemia/prevención & control , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Inyecciones Subcutáneas , Insulina/administración & dosificación , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Italia , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Países Bajos , Reproducibilidad de los Resultados
12.
Diabetes Obes Metab ; 17(5): 468-76, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25600304

RESUMEN

AIMS: To test in an outpatient setting the safety and efficacy of continuous subcutaneous insulin infusion (CSII) driven by a modular model predictive control (MMPC) algorithm informed by continuous glucose monitoring (CGM) measurement. METHODS: 13 patients affected by type 1 diabetes participated to a non-randomized outpatient 42-h experiment that included two evening meals and overnight periods (in short, dinner & night periods). CSII was patient-driven during dinner & night period 1 and MMPC-driven during dinner&night period 2. The study was conducted in hotels, where patients could move around freely. A CGM system (G4 Platinum; Dexcom Inc., San Diego, CA, USA) and insulin pump (AccuChek Combo; Roche Diagnostics, Mannheim, Germany) were connected wirelessly to a smartphone-based platform (DiAs, Diabetes Assistant; University of Virginia, Charlottesville, VA, USA) during both periods. RESULTS: A significantly lower percentage of time spent with glucose levels <3.9 mmol/l was achieved in period 2 compared with period 1: 1.96 ± 4.56% vs 12.76 ± 15.84% (mean ± standard deviation, p < 0.01), together with a greater percentage of time spent in the 3.9-10 mmol/l target range: 83.56 ± 14.02% vs 62.43 ± 29.03% (p = 0.04). In addition, restricting the analysis to the overnight phases, a lower percentage of time spent with glucose levels <3.9 mmol/l (1.92 ± 4.89% vs 12.7 ± 19.75%; p = 0.03) was combined with a greater percentage of time spent in 3.9-10 mmol/l target range in period 2 compared with period 1 (92.16 ± 8.03% vs 63.97 ± 2.73%; p = 0.01). Average glucose levels were similar during both periods. CONCLUSIONS: The results suggest that MMPC managed by a wearable system is safe and effective during evening meal and overnight. Its sustained use during this period is currently being tested in an ongoing randomized 2-month study.


Asunto(s)
Glucemia/análisis , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Páncreas Artificial , Adulto , Anciano , Algoritmos , Atención Ambulatoria , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 1/sangre , Cronoterapia de Medicamentos , Femenino , Humanos , Hipoglucemia/sangre , Masculino , Comidas , Persona de Mediana Edad , Factores de Tiempo , Resultado del Tratamiento
14.
Nutr Metab Cardiovasc Dis ; 23(7): 606-11, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22749531

RESUMEN

BACKGROUND AND AIMS: Costs associated with diabetes represent a large burden for patients and the health-care system. However, few studies examined the costs for diabetes treatment in adults with type 1 diabetes (T1DM). This analysis was aimed to assess the costs of treatment associated with T1DM among adults in Italy from the national health-care system perspective. METHODS AND RESULTS: Data were collected using a questionnaire assessing resource consumption retrospectively (drugs, visits, diagnostics, hospitalisations and self-monitoring of blood glucose (SMBG)). One-year costs were calculated for the 12 months preceding the survey. Cost estimation, referred to 2006, was carried out using univariate and multivariate Poisson regression models. Fifty-eight centres enrolled 1193 patients (49.5% women; aged between 18 and 55 years, average diabetes duration was 16.1 ± 9.8 years). The average annual cost for an adult patient with TDM1 was € 2450 (95% confidence interval (CI): 2358-2544). Insulin therapy and SMBG accounted together for 71.2% of total costs (35.6% and 35.6%, respectively); the remainder was shared by hospitalisations (18%), visits (4.0%), diagnostics (3.9%) and other drugs (2.9%). Univariate analyses showed that the presence of complications was associated with excess of costs, mainly related to the hospitalisation and drugs. Multivariate analyses confirmed these results showing that the presence of micro-vascular plus macrovascular complications doubles the cost of treatment. CONCLUSION: Strategies of care for T1DM that can improve disease management and prevent or delay the onset of complications could represent the most important tool to reduce costs in the long term while improving clinical outcomes and quality of life.


Asunto(s)
Costo de Enfermedad , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Angiopatías Diabéticas/terapia , Costos de la Atención en Salud , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Adolescente , Adulto , Automonitorización de la Glucosa Sanguínea/economía , Estudios de Casos y Controles , Costos y Análisis de Costo , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/economía , Angiopatías Diabéticas/economía , Angiopatías Diabéticas/prevención & control , Costos de los Medicamentos , Femenino , Encuestas de Atención de la Salud , Humanos , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/economía , Insulina/administración & dosificación , Insulina/economía , Sistemas de Infusión de Insulina/economía , Italia , Masculino , Persona de Mediana Edad , Distribución de Poisson , Estudios Retrospectivos , Adulto Joven
15.
Diabet Med ; 28(10): 1158-67, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21294770

RESUMEN

AIMS: To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes. METHODS: In this investigator-initiated multi-centre trial (the Eurythmics Trial) in eight outpatient centres in Europe, we randomized 83 patients with Type 1 diabetes (40 women) currently treated with multiple daily injections, age 18-65 years and HbA(1c) ≥ 8.2% (≥ 66 mmol/mol) to 26 weeks of treatment with either a sensor-augmented insulin pump (n = 44) (Paradigm(®) REAL-Time) or continued with multiple daily injections (n = 39). Change in HbA(1c) between baseline and 26 weeks, sensor-derived endpoints and patient-reported outcomes were assessed. RESULTS: The trial was completed by 43/44 (98%) patients in the sensor-augmented insulin pump group and 35/39 (90%) patients in the multiple daily injections group. Mean HbA(1c) at baseline and at 26 weeks changed from 8.46% (SD 0.95) (69 mmol/mol) to 7.23% (SD 0.65) (56 mmol/mol) in the sensor-augmented insulin pump group and from 8.59% (SD 0.82) (70 mmol/mol) to 8.46% (SD 1.04) (69 mmol/mol) in the multiple daily injections group. Mean difference in change in HbA(1c) after 26 weeks was -1.21% (95% confidence interval -1.52 to -0.90, P < 0.001) in favour of the sensor-augmented insulin pump group. This was achieved without an increase in percentage of time spent in hypoglycaemia: between-group difference 0.0% (95% confidence interval -1.6 to 1.7, P = 0.96). There were four episodes of severe hypoglycaemia in the sensor-augmented insulin pump group and one episode in the multiple daily injections group (P = 0.21). Problem Areas in Diabetes and Diabetes Treatment Satisfaction Questionnaire scores improved in the sensor-augmented insulin pump group. CONCLUSIONS: Sensor augmented pump therapy effectively lowers HbA(1c) in patients with Type 1 diabetes suboptimally controlled with multiple daily injections.


Asunto(s)
Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/efectos de los fármacos , Hipoglucemiantes/administración & dosificación , Bombas de Infusión Implantables , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Adulto , Diabetes Mellitus Tipo 1/sangre , Diseño de Equipo , Europa (Continente)/epidemiología , Hemoglobina Glucada/metabolismo , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Inyecciones , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven
16.
Nutr Metab Cardiovasc Dis ; 20(1): 7-14, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19747804

RESUMEN

BACKGROUND AND AIMS: Aim of this study was to identify subgroups of adults with Type 1 Diabetes Mellitus (T1DM) treated with Continuous Subcutaneous Insulin Infusion (CSII) at higher risk of poor quality of life (QoL). A sample of consecutive patients completed the Diabetes Specific Quality of Life Scale (DSQOLS), investigating the daily burden and restrictions related to diabetes. Lower DSQOLS scores indicate worse QoL perception. METHODS AND RESULTS: The main results were obtained by using a regression-tree technique (RECursive Partitioning and AMalgamation - RECPAM) and multivariate logistic regression. Overall, 472 patients aged between 18 and 55 years were recruited by 43 Italian centers. RECPAM analysis led to the identification of 5 classes characterized by a marked difference in QoL. Male patients not reporting episodes of ketoacidosis and using CSII for >2 years had the lowest likelihood of scoring in the lower tertile of the DSQOLS summary score, and thus represented the reference category. Patients who reported > or =1 ketoacidosis episodes (OR = 5.4; 95% CI 2.4-12.1) and female patients with a duration of diabetes of <10 years (OR = 5.9; 95% CI 2.6-13.5) had the highest likelihood of reporting poor QoL, while females with longer diabetes duration (OR = 2.4; 95% CI 1.3-4.7) and males treated with CSII for < or =2 years (OR = 2.2; 95% CI 1.1-4.6) showed a two-fold risk of poor QoL. Patient age, diabetic complications and civil status were globally predictive variables associated with poor QoL. CONCLUSION: We identified subgroups of T1DM individuals treated with CSII showing a major impairment in QoL. Specific strategies are needed to help the patient cope with this therapeutic modality, especially during the initial phase of treatment.


Asunto(s)
Diabetes Mellitus Tipo 1/fisiopatología , Diabetes Mellitus Tipo 1/psicología , Sistemas de Infusión de Insulina/psicología , Insulina/administración & dosificación , Calidad de Vida/psicología , Actividades Cotidianas , Adolescente , Adulto , Actitud Frente a la Salud , Costo de Enfermedad , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Cetoacidosis Diabética/psicología , Femenino , Humanos , Inyecciones Subcutáneas , Insulina/análogos & derivados , Insulina/uso terapéutico , Masculino , Persona de Mediana Edad , Factores de Riesgo , Caracteres Sexuales , Estadística como Asunto , Encuestas y Cuestionarios , Factores de Tiempo , Adulto Joven
17.
Diabet Med ; 26(6): 602-8, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19538235

RESUMEN

AIMS: To compare the effect of continuous subcutaneous insulin infusion (CSII) and multiple daily insulin injections (MDI) on albumin excretion rate (AER) in Type 1 diabetic patients. METHODS: In a 3-year multicentre retrospective observational study, 110 Type 1 diabetic patients treated with CSII were compared with 110 patients treated with MDI matched at baseline for age, sex, diabetes duration and HbA(1c). At entry, 90 patients in each group had normal AER and 20 persistent microalbuminuria. AER, estimated glomerular filtration rate (eGFR), HbA(1c,) lipids and blood pressure were assessed. RESULTS: HbA(1c) was lower in the CSII than in the MDI group (8.1 +/- 0.9 vs. 8.4 +/- 1.3%; P < 0.005 after 3 years). Blood pressure and eGFR were similar during the study. AER [median (95% confidence interval)], similar at baseline [6.0 microg/min (9, 21) in the CSII group vs. 4.4 (8, 16) in the MDI group, NS] was significantly lower in the patients treated with CSII both at year 2 and at year 3 of follow-up [4.7 microg/min (6, 12) vs. 6.4 (13, 29), P < 0.002]. This difference was observed even when normo- and microalbuminuric patients were analysed separately. Nine patients progressed to microalbuminuria in the MDI group and only one in the CSII group. Nine patients regressed to normoalbuminuria in the CSII group, whereas only two regressed to normoalbuminuria in the MDI group. CONCLUSIONS: Despite a small benefit in terms of improved glycaemic control, CSII therapy may be useful in decreasing the progressive increase in AER in Type 1 diabetic patients.


Asunto(s)
Albuminuria/prevención & control , Diabetes Mellitus Tipo 1/terapia , Infusiones Subcutáneas , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Presión Sanguínea/fisiología , Femenino , Tasa de Filtración Glomerular/fisiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
18.
Diabet Med ; 25(2): 213-20, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18201210

RESUMEN

AIMS: The aim of this case-control study was to compare quality of life (QoL) and treatment satisfaction in adults with Type 1 diabetes (T1DM) treated with either continuous subcutaneous insulin infusion (CSII) or multiple daily injections (MDI). METHODS: Consecutive patients aged between 18 and 55 years, and attending diabetes clinics for a routine visit, completed the Diabetes-Specific Quality-of-Life Scale (DSQOLS), the Diabetes Treatment Satisfaction Questionnaire (DTSQ) and the SF-36 Health Survey (SF-36). Case (CSII) and control subjects (MDI) were recruited in a 1 : 2 ratio. RESULTS: Overall, 1341 individuals were enrolled by 62 diabetes clinics; 481 were cases and 860 control subjects. Cases had a longer diabetes duration and were more likely to have eye and renal complications. Age, school education, occupation and HbA(1c) were similar. Of control subjects, 90% followed glargine-based MDI regimens and 10% used NPH-based MDI regimens. On multivariate analysis, after adjusting for socioeconomic and clinical characteristics, scores in the following areas of the DSQOLS were higher in cases than control subjects: diet restrictions (beta = 5.96; P < 0.0001), daily hassles (beta = 3.57; P = 0.01) and fears about hypoglycaemia (beta = 3.88; P = 0.006). Treatment with CSII was also associated with a markedly higher DTSQ score (beta = 4.13; P < 0.0001) compared with MDI. Results were similar when CSII was compared separately with glargine- or NPH-based MDI regimens. CONCLUSIONS: This large, non-randomized, case-control study suggests quality of life gains deriving from greater lifestyle flexibility, less fear of hypoglycaemia, and higher treatment satisfaction, when CSII is compared with either glargine-based or NPH-based MDI regimens.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Insulina/análogos & derivados , Calidad de Vida/psicología , Adulto , Métodos Epidemiológicos , Femenino , Humanos , Inyecciones Subcutáneas , Insulina/administración & dosificación , Insulina Glargina , Sistemas de Infusión de Insulina , Insulina de Acción Prolongada , Masculino , Persona de Mediana Edad , Satisfacción del Paciente
19.
Diabet Med ; 25(3): 326-32, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18307459

RESUMEN

AIMS: The superiority of continuous subcutaneous insulin infusion (CSII) over multiple daily injections (MDI) with glargine is uncertain. In this randomized cross-over study, we compared CSII and MDI with glargine in patients with Type 1 diabetes well controlled with CSII. The primary end-point was glucose variability. METHODS: Thirty-nine patients [38.1 +/- 9.3 years old (mean +/- sd), diabetes duration 16.6 +/- 8.2 years, glycated haemoglobin (HbA(1c)) 7.6 +/- 0.8%], already on CSII for at least 6 months, were randomly assigned to CSII with lispro or MDI with lispro and glargine. After 4 months they were switched to the alternative treatment. During the last month of each treatment blood glucose variability was analysed using glucose standard deviation, mean amplitude of glycaemic excursions (MAGE), lability index and average daily risk range (ADRR). As secondary end-points we analysed blood glucose profile, HbA(1c), number of episodes of hypo- and hyperglycaemia, lipid profile, free fatty acids (FFA), growth hormone and treatment satisfaction. RESULTS: During CSII, glucose variability was 5-12% lower than during MDI with glargine. The difference was significant only before breakfast considering glucose standard deviation (P = 0.011), significant overall using MAGE (P = 0.016) and lability index (P = 0.005) and not significant using ADRR. Although HbA(1c) was similar during both treatments, during CSII blood glucose levels were significantly lower, hyperglycaemic episodes were fewer, daily insulin dose was less, FFA were lower and treatment satisfaction was greater than during MDI with glargine. The frequency of hypoglycaemic episodes was similar during both treatments. CONCLUSIONS: During CSII, glucose variability is lower, glycaemic control better and treatment satisfaction higher than during MDI with glargine.


Asunto(s)
Glucemia/metabolismo , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Insulina/análogos & derivados , Diabetes Mellitus Tipo 1/sangre , Relación Dosis-Respuesta a Droga , Humanos , Inyecciones , Insulina/administración & dosificación , Insulina Glargina , Sistemas de Infusión de Insulina , Insulina de Acción Prolongada , Satisfacción del Paciente , Estadística como Asunto
20.
Acta Diabetol ; 45(1): 61-6, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18227964

RESUMEN

Some studies have shown that fetal outcome observed in patients using insulin lispro is much the same as in pregnant women using regular insulin. This study aims to analyze the Italian data emerging from a multinational, multicenter, retrospective study on mothers with type 1 diabetes mellitus before pregnancy, comparing those treated with insulin lispro for at least 3 months before and 3 months after conception with those treated with regular insulin. The data collected on pregnant women with diabetes attending 15 Italian centers from 1998 to 2001 included: HbA1c at conception and during the first and third trimesters, frequency of severe hypoglycemic episodes, spontaneous abortions, mode and time of delivery, fetal malformations and mortality. Seventy-two diabetic pregnancies treated with lispro and 298 treated with regular insulin were analyzed, revealing a trend towards fewer hypoglycemic episodes in the former, who also had a significantly greater reduction in HbA1c during the first trimester. The rate of congenital malformations was similar in the offspring of the two groups of women treated with insulin lispro or regular insulin. These findings suggest that insulin lispro could be useful for the treatment of hyperglycemia in type 1 diabetic pregnant women.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Insulina/análogos & derivados , Insulina/uso terapéutico , Complicaciones del Embarazo/tratamiento farmacológico , Peso al Nacer , Cromatografía Líquida de Alta Presión , Diabetes Mellitus Tipo 1/complicaciones , Femenino , Hemoglobina Glucada/metabolismo , Humanos , Recién Nacido , Recién Nacido Pequeño para la Edad Gestacional , Insulina Lispro , Italia , Embarazo , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA