Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 171
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 102(1): 145-154, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37178388

RESUMEN

BACKGROUND: Mitral valve transcatheter edge-to-edge repair (M-TEER) is an effective option for treatment of mitral regurgitation (MR). We previously reported favorable 2-year outcomes for the PASCAL transcatheter valve repair system. OBJECTIVES: We report 3-year outcomes from the multinational, prospective, single-arm CLASP study with analysis by functional MR (FMR) and degenerative MR (DMR). METHODS: Patients with core-lab determined MR ≥ 3+ were deemed candidates for M-TEER by the local heart team. Major adverse events were assessed by an independent clinical events committee to 1 year and by sites thereafter. Echocardiographic outcomes were evaluated by the core laboratory to 3 years. RESULTS: The study enrolled 124 patients, 69% FMR; 31% DMR (60% NYHA class III-IVa, 100% MR ≥ 3+). The 3-year Kaplan-Meier estimate for survival was 75% (66% FMR; 92% DMR) and freedom from heart failure hospitalization (HFH) was 73% (64% FMR; 91% DMR), with 85% reduction in annualized HFH rate (81% FMR; 96% DMR) (p < 0.001). MR ≤ 2+ was achieved and maintained in 93% of patients (93% FMR; 94% DMR) and MR ≤ 1+ in 70% of patients (71% FMR; 67% DMR) (p < 0.001). The mean left ventricular end-diastolic volume (181 mL at baseline) decreased progressively by 28 mL [p < 0.001]. NYHA class I/II was achieved in 89% of patients (p < 0.001). CONCLUSIONS: The 3-year results from the CLASP study demonstrated favorable and durable outcomes with the PASCAL transcatheter valve repair system in patients with clinically significant MR. These results add to the growing body of evidence establishing the PASCAL system as a valuable therapy for patients with significant symptomatic MR.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios Prospectivos , Resultado del Tratamiento
2.
N Engl J Med ; 380(26): 2541-2550, 2019 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-30946551

RESUMEN

BACKGROUND: During the introduction of transcatheter aortic-valve replacement (TAVR) in the United States, requirements regarding procedural volume were mandated by the Centers for Medicare and Medicaid Services as a condition of reimbursement. A better understanding of the relationship between hospital volume of TAVR procedures and patient outcomes could inform policy decisions. METHODS: We analyzed data from the Transcatheter Valve Therapy Registry regarding procedural volumes and outcomes from 2015 through 2017. The primary analyses examined the association between hospital procedural volume as a continuous variable and risk-adjusted mortality at 30 days after transfemoral TAVR. Secondary analysis included risk-adjusted mortality according to quartile of hospital procedural volume. A sensitivity analysis was performed after exclusion of the first 12 months of transfemoral TAVR procedures at each hospital. RESULTS: Of 113,662 TAVR procedures performed at 555 hospitals by 2960 operators, 96,256 (84.7%) involved a transfemoral approach. There was a significant inverse association between annualized volume of transfemoral TAVR procedures and mortality. Adjusted 30-day mortality was higher and more variable at hospitals in the lowest-volume quartile (3.19%; 95% confidence interval [CI], 2.78 to 3.67) than at hospitals in the highest-volume quartile (2.66%; 95% CI, 2.48 to 2.85) (odds ratio, 1.21; P = 0.02). The difference in adjusted mortality between a mean annualized volume of 27 procedures in the lowest-volume quartile and 143 procedures in the highest-volume quartile was a relative reduction of 19.45% (95% CI, 8.63 to 30.26). After the exclusion of the first 12 months of TAVR procedures at each hospital, 30-day mortality remained higher in the lowest-volume quartile than in the highest-volume quartile (3.10% vs. 2.61%; odds ratio, 1.19; 95% CI, 1.01 to 1.40). CONCLUSIONS: An inverse volume-mortality association was observed for transfemoral TAVR procedures from 2015 through 2017. Mortality at 30 days was higher and more variable at hospitals with a low procedural volume than at hospitals with a high procedural volume. (Funded by the American College of Cardiology Foundation National Cardiovascular Data Registry and the Society of Thoracic Surgeons.).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Hospitales de Alto Volumen/estadística & datos numéricos , Hospitales de Bajo Volumen/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Centers for Medicare and Medicaid Services, U.S. , Femenino , Mortalidad Hospitalaria , Humanos , Reembolso de Seguro de Salud/normas , Masculino , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Resultado del Tratamiento , Estados Unidos/epidemiología
3.
JAMA ; 326(22): 2277-2286, 2021 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-34905030

RESUMEN

Importance: Patent foramen ovale (PFO)-associated strokes comprise approximately 10% of ischemic strokes in adults aged 18 to 60 years. While device closure decreases stroke recurrence risk overall, the best treatment for any individual is often unclear. Objective: To evaluate heterogeneity of treatment effect of PFO closure on stroke recurrence based on previously developed scoring systems. Design, Setting, and Participants: Investigators for the Systematic, Collaborative, PFO Closure Evaluation (SCOPE) Consortium pooled individual patient data from all 6 randomized clinical trials that compared PFO closure plus medical therapy vs medical therapy alone in patients with PFO-associated stroke, and included a total of 3740 participants. The trials were conducted worldwide from 2000 to 2017. Exposures: PFO closure plus medical therapy vs medical therapy alone. Subgroup analyses used the Risk of Paradoxical Embolism (RoPE) Score (a 10-point scoring system in which higher scores reflect younger age and the absence of vascular risk factors) and the PFO-Associated Stroke Causal Likelihood (PASCAL) Classification System, which combines the RoPE Score with high-risk PFO features (either an atrial septal aneurysm or a large-sized shunt) to classify patients into 3 categories of causal relatedness: unlikely, possible, and probable. Main Outcomes and Measures: Ischemic stroke. Results: Over a median follow-up of 57 months (IQR, 24-64), 121 outcomes occurred in 3740 patients. The annualized incidence of stroke with medical therapy was 1.09% (95% CI, 0.88%-1.36%) and with device closure was 0.47% (95% CI, 0.35%-0.65%) (adjusted hazard ratio [HR], 0.41 [95% CI, 0.28-0.60]). The subgroup analyses showed statistically significant interaction effects. Patients with low vs high RoPE Score had HRs of 0.61 (95% CI, 0.37-1.00) and 0.21 (95% CI, 0.11-0.42), respectively (P for interaction = .02). Patients classified as unlikely, possible, and probable using the PASCAL Classification System had HRs of 1.14 (95% CI, 0.53-2.46), 0.38 (95% CI, 0.22-0.65), and 0.10 (95% CI, 0.03-0.35), respectively (P for interaction = .003). The 2-year absolute risk reduction was -0.7% (95% CI, -4.0% to 2.6%), 2.1% (95% CI, 0.6%-3.6%), and 2.1% (95% CI, 0.9%-3.4%) in the unlikely, possible, and probable PASCAL categories, respectively. Device-associated adverse events were generally higher among patients classified as unlikely; the absolute risk increases in atrial fibrillation beyond day 45 after randomization with a device were 4.41% (95% CI, 1.02% to 7.80%), 1.53% (95% CI, 0.33% to 2.72%), and 0.65% (95% CI, -0.41% to 1.71%) in the unlikely, possible, and probable PASCAL categories, respectively. Conclusions and Relevance: Among patients aged 18 to 60 years with PFO-associated stroke, risk reduction for recurrent stroke with device closure varied across groups classified by their probabilities that the stroke was causally related to the PFO. Application of this classification system has the potential to guide individualized decision-making.


Asunto(s)
Anticoagulantes/uso terapéutico , Foramen Oval Permeable/cirugía , Accidente Cerebrovascular/tratamiento farmacológico , Adolescente , Adulto , Femenino , Fibrinolíticos/uso terapéutico , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/tratamiento farmacológico , Humanos , Masculino , Persona de Mediana Edad , Números Necesarios a Tratar , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Factores de Riesgo , Prevención Secundaria , Dispositivo Oclusor Septal , Accidente Cerebrovascular/etiología , Adulto Joven
4.
Stroke ; 51(10): 3119-3123, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32921262

RESUMEN

BACKGROUND AND PURPOSE: In patients with cryptogenic stroke and patent foramen ovale (PFO), the Risk of Paradoxical Embolism (RoPE) Score has been proposed as a method to estimate a patient-specific "PFO-attributable fraction"-the probability that a documented PFO is causally-related to the stroke, rather than an incidental finding. The objective of this research is to examine the relationship between this RoPE-estimated PFO-attributable fraction and the effect of closure in 3 randomized trials. METHODS: We pooled data from the CLOSURE-I (Evaluation of the STARFlex Septal Closure System in Patients With a Stroke and/or Transient Ischemic Attack due to Presumed Paradoxical Embolism through a Patent Foramen Ovale), RESPECT (Randomized Evaluation of Recurrent Stroke Comparing PFO Closure to Established Current Standard of Care Treatment), and PC (Clinical Trial Comparing Percutaneous Closure of Patent Foramen Ovale [PFO] Using the Amplatzer PFO Occluder With Medical Treatment in Patients With Cryptogenic Embolism) trials. We examine the treatment effect of closure in high RoPE score (≥7) versus low RoPE score (<7) patients. We also estimated the relative risk reduction associated with PFO closure across each level of the RoPE score using Cox proportional hazard analysis. We estimated a patient-specific attributable fraction using a PC trial-compatible (9-point) RoPE equation (omitting the neuroradiology variable), as well as a 2-trial analysis using the original (10-point) RoPE equation. We examined the Pearson correlation between the estimated attributable fraction and the relative risk reduction across RoPE strata. RESULTS: In the low RoPE score group (<7, n=912), the rate of recurrent strokes per 100 person-years was 1.37 in the device arm versus 1.68 in the medical arm (hazard ratio, 0.82 [0.42-1.59] P=0.56) compared with 0.30 versus 1.03 (hazard ratio, 0.31 [0.11-0.85] P=0.02) in the high RoPE score group (≥7, n=1221); treatment-by-RoPE score group interaction, P=0.12. The RoPE score estimated attributable fraction anticipated the relative risk reduction across all levels of the RoPE score, in both the 3-trial (r=0.95, P<0.001) and 2-trial (r=0.92, P<0.001) analyses. CONCLUSIONS: The RoPE score estimated attributable fraction is highly correlated to the relative risk reduction of device versus medical therapy. This observation suggests the RoPE score identifies patients with cryptogenic stroke who are likely to have a PFO that is pathogenic rather than incidental.


Asunto(s)
Embolia Paradójica/etiología , Foramen Oval Permeable/complicaciones , Accidente Cerebrovascular/complicaciones , Cateterismo Cardíaco , Foramen Oval Permeable/cirugía , Humanos , Factores de Riesgo , Prevención Secundaria , Resultado del Tratamiento
6.
N Engl J Med ; 377(11): 1022-1032, 2017 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-28902590

RESUMEN

BACKGROUND: Whether closure of a patent foramen ovale reduces the risk of recurrence of ischemic stroke in patients who have had a cryptogenic ischemic stroke is unknown. METHODS: In a multicenter, randomized, open-label trial, with blinded adjudication of end-point events, we randomly assigned patients 18 to 60 years of age who had a patent foramen ovale (PFO) and had had a cryptogenic ischemic stroke to undergo closure of the PFO (PFO closure group) or to receive medical therapy alone (aspirin, warfarin, clopidogrel, or aspirin combined with extended-release dipyridamole; medical-therapy group). The primary efficacy end point was a composite of recurrent nonfatal ischemic stroke, fatal ischemic stroke, or early death after randomization. The results of the analysis of the primary outcome from the original trial period have been reported previously; the current analysis of data from the extended follow-up period was considered to be exploratory. RESULTS: We enrolled 980 patients (mean age, 45.9 years) at 69 sites. Patients were followed for a median of 5.9 years. Treatment exposure in the two groups was unequal (3141 patient-years in the PFO closure group vs. 2669 patient-years in the medical-therapy group), owing to a higher dropout rate in the medical-therapy group. In the intention-to-treat population, recurrent ischemic stroke occurred in 18 patients in the PFO closure group and in 28 patients in the medical-therapy group, resulting in rates of 0.58 events per 100 patient-years and 1.07 events per 100 patient-years, respectively (hazard ratio with PFO closure vs. medical therapy, 0.55; 95% confidence interval [CI], 0.31 to 0.999; P=0.046 by the log-rank test). Recurrent ischemic stroke of undetermined cause occurred in 10 patients in the PFO closure group and in 23 patients in the medical-therapy group (hazard ratio, 0.38; 95% CI, 0.18 to 0.79; P=0.007). Venous thromboembolism (which comprised events of pulmonary embolism and deep-vein thrombosis) was more common in the PFO closure group than in the medical-therapy group. CONCLUSIONS: Among adults who had had a cryptogenic ischemic stroke, closure of a PFO was associated with a lower rate of recurrent ischemic strokes than medical therapy alone during extended follow-up. (Funded by St. Jude Medical; RESPECT ClinicalTrials.gov number, NCT00465270 .).


Asunto(s)
Anticoagulantes/uso terapéutico , Foramen Oval Permeable/tratamiento farmacológico , Foramen Oval Permeable/terapia , Inhibidores de Agregación Plaquetaria/uso terapéutico , Prevención Secundaria/métodos , Dispositivo Oclusor Septal , Accidente Cerebrovascular/prevención & control , Adolescente , Adulto , Anticoagulantes/efectos adversos , Quimioterapia Combinada , Femenino , Estudios de Seguimiento , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/mortalidad , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/efectos adversos , Recurrencia , Dispositivo Oclusor Septal/efectos adversos , Método Simple Ciego , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Tromboembolia Venosa/etiología , Adulto Joven
7.
Echocardiography ; 37(5): 769-780, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32338402

RESUMEN

Increased catheter-based interventions in congenital and structural heart disease require imaging modalities to be oriented in the same visual perspective. The use of echocardiography-fluoroscopy fusion (EFF) imaging has been developed for better characterization of complex anatomy and to facilitate key steps in interventional procedures. This review will detail the technology behind EFF, the differences between the two ultrasound fusion systems, and essential features of EFF imaging in congenital and structural heart disease interventions.


Asunto(s)
Cardiopatías Congénitas , Radiografía Intervencional , Cateterismo Cardíaco , Ecocardiografía , Fluoroscopía , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Imagen Multimodal , Ultrasonografía Intervencional
8.
Catheter Cardiovasc Interv ; 93(5): 859-874, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30896894

RESUMEN

Until recently, evidence to support Patent Foramen Ovale (PFO) closure for secondary prevention of recurrent stroke has been controversial. Publication of high-quality evidence from randomized clinical trials and the subsequent FDA approval of two devices for percutaneous PFO closure is expected to increase the volume of PFO closure procedures not only in the United States but worldwide. As this technology is disseminated broadly to the public, ensuring the safe and efficacious performance of PFO closure is essential to mitigate risk and avoid unnecessary procedures. This document, prepared by a multi-disciplinary writing group convened by the Society for Cardiovascular Angiography and Interventions and including representatives from the American Academy of Neurology, makes recommendations for institutional infrastructure and individual skills necessary to initiate and maintain an active PFO/stroke program, with emphasis on shared decision making and patient-centered care.


Asunto(s)
Cateterismo Cardíaco , Educación de Postgrado en Medicina , Embolia Paradójica/prevención & control , Foramen Oval Permeable/terapia , Neurólogos/educación , Prevención Secundaria/educación , Accidente Cerebrovascular/prevención & control , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Toma de Decisiones Clínicas , Consenso , Embolia Paradójica/diagnóstico por imagen , Embolia Paradójica/etiología , Embolia Paradójica/fisiopatología , Medicina Basada en la Evidencia , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico por imagen , Foramen Oval Permeable/fisiopatología , Humanos , Seguridad del Paciente , Recurrencia , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/fisiopatología , Resultado del Tratamiento
9.
Echocardiography ; 36(4): 732-741, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30801804

RESUMEN

BACKGROUND: The effects of edge-to-edge percutaneous mitral valve repair on the shape and size of the mitral annulus and its relation to mitral regurgitation (MR) have not been well characterized. We evaluated acute changes in mitral annular shape and dimensions, and their effect on MR severity, in patients with functional and degenerative MR following MitraClip® . METHODS: Patients that underwent MitraClip® between January 2013 and May 2016 at our institution were retrospectively reviewed. EXCLUSIONS: inadequate images, prior mitral valve repair, and rapid atrial fibrillation. Intra-procedure TEE 3D images acquired prior to and after implantation of MitraClip® were analyzed using software to model the mitral valve apparatus. RESULTS: Of seventy-eight patients that underwent MitraClip® procedure, 60 were eligible. Mean age was 78.3 ± 11 years. Severe MR (4+) was present in 37 patients, moderately/severe MR (3+) in 23. All patients achieved MR reduction to ≤2. 3D annular circumference, bicommissural diameter, and anteroposterior diameter had a significant size reduction after MitraClip® . None of the mitral annular measures had significantly different mean change between the large and small MR change groups at the 0.05 significance level. CONCLUSIONS: In patients with functional or degenerative MR, the MitraClip® significantly affect mitral annular dimensions; however, these changes do not correlate with the immediate MR reduction.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/fisiopatología , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
10.
Curr Cardiol Rep ; 21(6): 48, 2019 04 22.
Artículo en Inglés | MEDLINE | ID: mdl-31011896

RESUMEN

PURPOSE OF REVIEW: This review summarizes the most recent randomized clinical trials that studied the role of device-mediated patent foramen ovale (PFO) closure in patients after an ischemic stroke presumed to have been caused by a paradoxical embolism. RECENT FINDINGS: Three major randomized trials published in 2017 studied the strategy of using PFO closure for secondary prevention in patients between the ages of 18 and 60 who presented with an index stroke having characteristics of an embolic mechanism. All patients had a PFO that potentially could have enabled paradoxical embolism and other causes of stroke were excluded by a thorough neurologic and cardiac evaluation. Patients were randomized to PFO closure versus medical therapy alone using a variety of guideline-recommended medications. After multiple years of follow-up, all three trials showed superiority in the device arm versus the medical arm with a relative risk reduction of recurrent stroke from 46 to 100% and an absolute recurrent stroke reduction from 0.49 to 1.32% per year. Complications related to the procedure and the device were infrequent and mostly transient. These results have transformed the care of these patients, lead to FDA approval of two PFO closure devices, and started the process of updating guidelines. Patient selection is critically important since the presence of a PFO may be incidental. Therefore, both a neurologist and a cardiologist, who can also perform this procedure safely and effectively, should complete the initial evaluation and discuss their findings and recommendations with the patient as part of a shared decision-making process. There are remaining questions regarding how these trial results relate to older patients, patients with overt venothrombotic disease, and those with thrombophilia.


Asunto(s)
Foramen Oval Permeable/cirugía , Implantación de Prótesis/instrumentación , Dispositivo Oclusor Septal , Accidente Cerebrovascular/cirugía , Embolia/etiología , Foramen Oval Permeable/complicaciones , Humanos , Selección de Paciente , Ensayos Clínicos Controlados Aleatorios como Asunto , Prevención Secundaria , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
11.
Stroke ; 49(6): 1443-1450, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29720435

RESUMEN

BACKGROUND AND PURPOSE: Percutaneous transcatheter closure of patent foramen ovale (PFO closure) plus antiplatelet therapy has been shown to reduce the risk of recurrent stroke compared with medical therapy alone in carefully selected patients after cryptogenic stroke presumed to be from paradoxical embolism. Our objective was to determine the cost-effectiveness of PFO closure after cryptogenic stroke compared with conservative medical management from a US healthcare payer perspective. METHODS: A decision analytic Markov model estimated the 15-year cost and outcomes associated with the additional benefit of PFO closure compared with medical management alone. Model inputs were obtained from published literature, national databases, and a meta-analysis of 5 published randomized clinical trials on PFO closure. Health outcomes were measured in quality-adjusted life years (QALY). Cost-effectiveness used the incremental cost per QALY gained, whereas the net monetary benefit assumed a willingness to pay of $150 000/QALY. One-way and probabilistic sensitivity analyses estimated the uncertainty of model results. RESULTS: At 15 years, PFO closure compared with medical therapy alone improved QALY by 0.33 at a cost saving of $3568, representing an incremental net monetary benefit of $52 761 (95% interval -$8284 to $158 910). When the meta-analysis hazard ratio for stroke was increased to the 95% interval's upper bound of 0.77, one-way sensitivity analyses suggested that PFO closure's cost-effectiveness was $458 558 per additional QALY. Probabilistic sensitivity analysis suggested cost-effectiveness in 90% of simulation runs. CONCLUSIONS: PFO closure for cryptogenic strokes in the right setting is cost-effective, producing benefit in QALYs gained and potential cost savings. However, patient selection remains vitally important as marginal declines in treatment effectiveness can dramatically affect cost-effectiveness.


Asunto(s)
Análisis Costo-Beneficio , Foramen Oval Permeable/tratamiento farmacológico , Prevención Secundaria , Accidente Cerebrovascular/tratamiento farmacológico , Cateterismo Cardíaco/economía , Cateterismo Cardíaco/métodos , Foramen Oval Permeable/complicaciones , Humanos , Modelos de Riesgos Proporcionales , Factores de Riesgo , Prevención Secundaria/métodos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
12.
Curr Cardiol Rep ; 20(6): 37, 2018 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-29666940

RESUMEN

PURPOSE OF REVIEW: While the safety and efficacy of percutaneous ASD closure has been established, new data have recently emerged regarding the negative impact of residual iatrogenic ASD (iASD) following left heart structural interventions. Additionally, new devices with potential advantages have recently been studied. We will review here the potential indications for closure of iASD along with new generation closure devices and potential late complications requiring long-term follow-up. RECENT FINDINGS: With the expansion of left-heart structural interventions and large-bore transseptal access, there has been growing experience gained with management of residual iASD. Some recently published reports have implicated residual iASD after these procedures as a potential source of diminished clinical outcomes and mortality. Additionally, recent trials investigating new generation closure devices as well as expanding knowledge regarding late complications of percutaneous ASD closure have been published. While percutaneous ASD closure is no longer a novel approach to managing septal defects, there are several contemporary issues related to residual iASD following large-bore transseptal access and new generation devices which serve as an impetus for this review. Ongoing attention to potential late complications and decreasing their incidence with ongoing study is clearly needed.


Asunto(s)
Fibrilación Atrial/complicaciones , Cateterismo Cardíaco/efectos adversos , Defectos del Tabique Interatrial/cirugía , Enfermedad Iatrogénica , Dispositivo Oclusor Septal , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/instrumentación , Ecocardiografía Transesofágica , Lesiones Cardíacas/etiología , Lesiones Cardíacas/fisiopatología , Lesiones Cardíacas/cirugía , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/fisiopatología , Humanos , Resultado del Tratamiento
13.
JAMA ; 320(21): 2231-2241, 2018 12 04.
Artículo en Inglés | MEDLINE | ID: mdl-30512100

RESUMEN

Importance: Data are lacking on the effect of a renin-angiotensin system (RAS) inhibitor prescribed after transcatheter aortic valve replacement (TAVR). Treatment with a RAS inhibitor may reverse left ventricular remodeling and improve function. Objective: To investigate the association of prescription of a RAS inhibitor and outcomes after TAVR. Design, Setting, and Participants: Retrospective cohort study of TAVR procedures performed in the United States (using the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry) between July 2014 and January 2016 that were linked to Medicare claims data (final date of follow-up: March 31, 2017). To account for differences in demographics, echocardiographic findings, and in-hospital complications, 1:1 propensity matching was performed. Exposures: Initial hospital discharge prescription of a RAS inhibitor after TAVR. Main Outcomes and Measures: Primary outcomes were all-cause death and readmission due to heart failure at 1 year after discharge, which were considered separately. The secondary outcome was health status assessed by the Kansas City Cardiomyopathy Questionnaire (KCCQ; score range: 0-100, with a higher score indicating less symptom burden and better quality of life; a small effect size was defined as 5 points) at 1 year. Results: Among 21 312 patients who underwent TAVR at 417 US sites, 8468 patients (39.7%) were prescribed a RAS inhibitor at hospital discharge. After propensity matching, 15 896 patients were included (mean [SD] age, 82.4 [6.8] years; 48.1% were women; mean [SD] left ventricular ejection fraction [LVEF], 51.9% [11.5%]). Patients with a prescription for a RAS inhibitor vs those with no prescription had lower mortality rates at 1 year (12.5% vs 14.9%, respectively; absolute risk difference [ARD], -2.4% [95% CI, -3.5% to -1.4%]; hazard ratio [HR], 0.82 [95% CI, 0.76 to 0.90]) and lower heart failure readmission rates at 1 year (12.0% vs 13.8%; ARD, -1.8% [95% CI, -2.8% to -0.7%]; HR, 0.86 [95% CI, 0.79 to 0.95]). When stratified by LVEF, having a prescription for a RAS inhibitor vs no prescription was associated with lower 1-year mortality among patients with preserved LVEF (11.1% vs 13.9%, respectively; ARD, -2.81% [95% CI, -3.95% to -1.67%]; HR, 0.78 [95% CI, 0.71 to 0.86]), but not among those with reduced LVEF (18.8% vs 19.5%; ARD, -0.68% [95% CI, -3.52% to 2.20%]; HR, 0.95 [95% CI, 0.81 to 1.12]) (P = .04 for interaction). Of 15 896 matched patients, 4837 (30.4%) were included in the KCCQ score analysis and improvements at 1 year were greater in patients with a prescription for a RAS inhibitor vs those with no prescription (median, 33.3 [interquartile range, 14.2 to 51.0] vs 31.3 [interquartile range, 13.5 to 51.1], respectively; difference in improvement, 2.10 [95% CI, 0.10 to 4.06]; P < .001), but the effect size was not clinically meaningful. Conclusions and Relevance: Among patients who underwent TAVR, receiving a prescription for a RAS inhibitor at hospital discharge compared with no prescription was significantly associated with a lower risk of mortality and heart failure readmission. However, due to potential selection bias, this finding requires further investigation in randomized trials.


Asunto(s)
Antagonistas de Receptores de Angiotensina/uso terapéutico , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Estenosis de la Válvula Aórtica/cirugía , Insuficiencia Cardíaca/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Causas de Muerte , Femenino , Insuficiencia Cardíaca/etiología , Humanos , Masculino , Readmisión del Paciente , Puntaje de Propensión , Calidad de Vida , Sistema Renina-Angiotensina/efectos de los fármacos , Estudios Retrospectivos , Prevención Secundaria , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
15.
N Engl J Med ; 368(12): 1092-100, 2013 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-23514286

RESUMEN

BACKGROUND: Whether closure of a patent foramen ovale is effective in the prevention of recurrent ischemic stroke in patients who have had a cryptogenic stroke is unknown. We conducted a trial to evaluate whether closure is superior to medical therapy alone in preventing recurrent ischemic stroke or early death in patients 18 to 60 years of age. METHODS: In this prospective, multicenter, randomized, event-driven trial, we randomly assigned patients, in a 1:1 ratio, to medical therapy alone or closure of the patent foramen ovale. The primary results of the trial were analyzed when the target of 25 primary end-point events had been observed and adjudicated. RESULTS: We enrolled 980 patients (mean age, 45.9 years) at 69 sites. The medical-therapy group received one or more antiplatelet medications (74.8%) or warfarin (25.2%). Treatment exposure between the two groups was unequal (1375 patient-years in the closure group vs. 1184 patient-years in the medical-therapy group, P=0.009) owing to a higher dropout rate in the medical-therapy group. In the intention-to-treat cohort, 9 patients in the closure group and 16 in the medical-therapy group had a recurrence of stroke (hazard ratio with closure, 0.49; 95% confidence interval [CI], 0.22 to 1.11; P=0.08). The between-group difference in the rate of recurrent stroke was significant in the prespecified per-protocol cohort (6 events in the closure group vs. 14 events in the medical-therapy group; hazard ratio, 0.37; 95% CI, 0.14 to 0.96; P=0.03) and in the as-treated cohort (5 events vs. 16 events; hazard ratio, 0.27; 95% CI, 0.10 to 0.75; P=0.007). Serious adverse events occurred in 23.0% of the patients in the closure group and in 21.6% in the medical-therapy group (P=0.65). Procedure-related or device-related serious adverse events occurred in 21 of 499 patients in the closure group (4.2%), but the rate of atrial fibrillation or device thrombus was not increased. CONCLUSIONS: In the primary intention-to-treat analysis, there was no significant benefit associated with closure of a patent foramen ovale in adults who had had a cryptogenic ischemic stroke. However, closure was superior to medical therapy alone in the prespecified per-protocol and as-treated analyses, with a low rate of associated risks. (Funded by St. Jude Medical; RESPECT ClinicalTrials.gov number, NCT00465270.).


Asunto(s)
Fibrinolíticos/uso terapéutico , Foramen Oval Permeable/terapia , Prevención Secundaria , Dispositivo Oclusor Septal , Accidente Cerebrovascular/prevención & control , Adulto , Cateterismo Cardíaco/efectos adversos , Embolia/etiología , Embolia/prevención & control , Femenino , Fibrinolíticos/efectos adversos , Estudios de Seguimiento , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/tratamiento farmacológico , Foramen Oval Permeable/mortalidad , Humanos , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Riesgo , Dispositivo Oclusor Septal/efectos adversos , Método Simple Ciego , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
17.
J Interv Cardiol ; 28(5): 493-7, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26381865

RESUMEN

OBJECTIVES: A novel radiation dose reduction technology was evaluated in a cardiac catheterization laboratory during routine clinical care to determine if it could reduce radiation dose to patients undergoing coronary angiography and percutaneous coronary intervention. These results were compared to patients undergoing similar procedures in a cardiac catheterization laboratory without this technology. BACKGROUND: There is a safety priority in clinical care to reduce X-ray radiation dose to patients in order to lower the risk of deterministic and stochastic effects. Dose reduction technologies must be verified in clinical settings to prove if they reduce X-ray radiation dose and to what extent. METHODS: Radiation dose data and procedure characteristics of 268 consecutive patients were collected and analyzed from a cardiac catheterization laboratory with dose reduction technology installed (referred to as Lab A, n = 135) and from a cardiac catheterization laboratory without this technology (referred as Lab B, n = 133). RESULTS: For diagnostic procedures, the median total dose-area product in Lab A was reduced by 46% (P < 0.0001) compared to Lab B, with no differences in terms of body mass index (P = 0.180), total fluoroscopy times (P = 1), number of acquired images (P = 0.920), and contrast medium (P = 0.660). For interventional procedures, the median total dose-area product in Lab A was reduced by 34% (P = 0.015) compared to Lab B, with no differences in terms of body mass index (P = 0.665), total fluoroscopy times (P = 0.765), number of acquired images (P = 0.923), and contrast medium (P = 0.969). CONCLUSIONS: This new dose reduction technology significantly reduces X-ray radiation dose without affecting fluoroscopy time, number of images, and contrast medium used during diagnostic and interventional coronary procedures.


Asunto(s)
Angiografía Coronaria , Fluoroscopía , Procesamiento de Imagen Asistido por Computador/métodos , Intervención Coronaria Percutánea , Dosis de Radiación , Traumatismos por Radiación , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Protocolos Clínicos , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Femenino , Fluoroscopía/efectos adversos , Fluoroscopía/métodos , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Seguridad del Paciente , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Mejoramiento de la Calidad , Traumatismos por Radiación/etiología , Traumatismos por Radiación/prevención & control , Salud Radiológica/métodos , Salud Radiológica/normas , Evaluación de la Tecnología Biomédica/métodos
18.
Catheter Cardiovasc Interv ; 94(1): 3-26, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31002751
19.
Catheter Cardiovasc Interv ; 93(3): E153-E184, 2019 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-30265423
20.
Echocardiography ; 31(4): 420-7, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24138568

RESUMEN

Although the "3 beat rule" is widely utiized to discriminate patent foramen ovale (PFO)-mediated right-to-left shunt (RTLS) from intrapulmonary RTLS using saline contrast transthoracic echocardiography (SCE), SCE diagnostic performance has yet to be validated using an invasive intracardiac standard. Percutaneous PFO occluder placement was recently shown to ameliorate hypoxia in patients with suspected PFO-mediated RTLS. We evaluated the ability of SCE to predict PFO presence and size using intracardiac echocardiography (ICE) as a gold standard in a hypoxic cohort. Sixty-three hypoxic patients with suspected PFO-mediated RTLS who underwent SCE at rest, with Valsalva maneuver, and with cough prior to ICE were evaluated retrospectively. PFO RTLS was defined by ICE findings including PFO anatomy, RTLS by saline contrast and color Doppler, and probe patency. SCE shunt severity and timing of left heart saline target appearance were compared to the presence of ICE-defined PFO RTLS. Forty-seven patients (75%) met criteria for PFO-mediated RTLS. A 4 beat cutoff for resting SCE provided optimal diagnostic performance for detection of PFO-mediated RTLS with a 71% sensitivity, 94% specificity, and 97% positive predictive value (PPV). Valsalva and cough maneuvers improved sensitivity compared to rest SCE (89% and 80%, respectively). Valsalva SCE shunt severity more accurately predicted PFO size than resting SCE. In contrast to the widely accepted "3 beat rule," resting SCE for the detection of PFO RTLS in a hypoxic population performs optimally using a 4-cycle cutoff with both excellent specificity and PPV.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Foramen Oval Permeable/diagnóstico por imagen , Aumento de la Imagen/métodos , Cloruro de Sodio , Ultrasonografía Intervencional/métodos , Anciano , Cateterismo Cardíaco , Catéteres Cardíacos , Estudios de Cohortes , Ecocardiografía Transesofágica/métodos , Femenino , Foramen Oval Permeable/diagnóstico , Humanos , Hipoxia/diagnóstico , Hipoxia/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA