1.
Anal Bioanal Chem ; 416(6): 1407-1415, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38246908

RESUMEN

Wearable glucose biosensors enable noninvasive glucose monitoring, thereby enhancing blood glucose management. In this work, we present a wearable biosensor based on carbon black nanoparticles (CBNPs) for glucose detection in human sweat. The biosensor consists of CBNPs, Prussian blue (PB), glucose oxidase, chitosan, and Nafion. The fabricated biosensor has a linear range of 5 µM to 1250 µM, sensitivity of 14.64 µA mM-1 cm-2, and a low detection potential (-0.05 V, vs. Ag/AgCl). The detection limit for glucose was calculated as 4.83 µM. This reusable biosensor has good selectivity and stability and exhibits a good response to glucose in real sweat. These results demonstrate the potential of our CBNP-based biosensor for monitoring blood glucose in human sweat.


Asunto(s)
Técnicas Biosensibles , Nanopartículas , Dispositivos Electrónicos Vestibles , Humanos , Sudor , Hollín , Glucemia , Automonitorización de la Glucosa Sanguínea , Técnicas Biosensibles/métodos , Glucosa , Glucosa Oxidasa
2.
Anal Methods ; 12(20): 2560-2570, 2020 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-32930282

RESUMEN

Blood plasma separation is a vital sample pre-treatment procedure for microfluidic devices in blood diagnostics, and it requires reliability and speediness. In this work, we propose a novel and simple method for microvolume blood plasma separation driven by capillary force. Flat-shaped filter membranes combined with hydrophilic narrow capillaries are introduced into devices, in order to reduce the residual volumes of blood plasma. An interference fit is used to ensure no leakage of blood or cells. There is desired trapping efficiency of blood cells in the devices. The method provides high efficiency with a plasma extraction yield of 71.7% within 6 min, using 60 µL of undiluted whole human blood with 45% haematocrit. The influence from structural parameters on the separation kinetics and the dependence of the haematocrit levels on the separation efficiency are also investigated. The total protein detection shows considerable protein recovery of 82.3% in the extracted plasma. Thus, the plasma separation unit with a very simple structure is suitable for integrating into microfluidic devices, presenting promising prospects for clinical diagnostics as well as for point-of-care testing applications.


Asunto(s)
Técnicas Analíticas Microfluídicas , Capilares , Humanos , Dispositivos Laboratorio en un Chip , Plasma , Reproducibilidad de los Resultados