Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Nat Immunol ; 15(2): 128-35, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24448570

RESUMEN

The complex heterogeneity of cells, and their interconnectedness with each other, are major challenges to identifying clinically relevant measurements that reflect the state and capability of the immune system. Highly multiplexed, single-cell technologies may be critical for identifying correlates of disease or immunological interventions as well as for elucidating the underlying mechanisms of immunity. Here we review limitations of bulk measurements and explore advances in single-cell technologies that overcome these problems by expanding the depth and breadth of functional and phenotypic analysis in space and time. The geometric increases in complexity of data make formidable hurdles for exploring, analyzing and presenting results. We summarize recent approaches to making such computations tractable and discuss challenges for integrating heterogeneous data obtained using these single-cell technologies.


Asunto(s)
Sistema Inmunológico/metabolismo , Técnicas Inmunológicas , Monitorización Inmunológica/métodos , Análisis de la Célula Individual/métodos , Animales , Biología Computacional , Humanos , Sistema Inmunológico/patología , Estadística como Asunto
2.
Cytometry A ; 101(1): 27-44, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34390166

RESUMEN

T-cell activation is a key step in the amplification of an immune response. Over the course of an immune response, cells may be chronically stimulated, with some proportion becoming exhausted; an enormous number of molecules are involved in this process. There remain a number of questions about the process, namely: (1) what degree of heterogeneity and plasticity do T-cells exhibit during stimulation? (2) how many unique cell states define chronic stimulation? and (3) what markers discriminate activated from exhausted cells? We addressed these questions by performing single-cell multiomic analysis to simultaneously measure expression of 38 proteins and 399 genes in human T cells expanded in vitro. This approach allowed us to study -with unprecedented depth-how T cells change over the course of chronic stimulation. Comprehensive immunophenotypic and transcriptomic analysis at day 0 enabled a refined characterization of T-cell maturational states and the identification of a donor-specific subset of terminally differentiated T-cells that would have been otherwise overlooked using canonical cell classification schema. As expected, activation downregulated naïve-cell markers and upregulated effector molecules, proliferation regulators, co-inhibitory and co-stimulatory receptors. Our deep kinetic analysis further revealed clusters of proteins and genes identifying unique states of activation, defined by markers temporarily expressed upon 3 days of stimulation (PD-1, CD69, LTA), markers constitutively expressed throughout chronic activation (CD25, GITR, LGALS1), and markers uniquely up-regulated upon 14 days of stimulation (CD39, ENTPD1, TNFDF10); expression of these markers could be associated with the emergence of short-lived cell types. Notably, different ratios of cells expressing activation or exhaustion markers were measured at each time point. These data reveal the high heterogeneity and plasticity of chronically stimulated T cells. Our study demonstrates the power of a single-cell multiomic approach to comprehensively characterize T-cells and to precisely monitor changes in differentiation, activation, and exhaustion signatures during cell stimulation.


Asunto(s)
Linfocitos T CD8-positivos , Activación de Linfocitos , Humanos , Inmunofenotipificación , Cinética , Análisis de la Célula Individual
3.
Cytometry A ; 99(1): 11-18, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32881296

RESUMEN

Cytometry is playing a crucial role in addressing the COVID-19 pandemic. In this commentary-written by a variety of stakeholders in the cytometry, immunology, and infectious disease communities-we review cytometry's role in the COVID-19 response and discuss workflow issues critical to planning and executing effective research in this emerging field. We discuss sample procurement and processing, biosafety, technology options, data sharing, and the translation of research findings into clinical environments. © 2020 International Society for Advancement of Cytometry.


Asunto(s)
COVID-19/prevención & control , Contención de Riesgos Biológicos/tendencias , Citometría de Flujo/tendencias , SARS-CoV-2/aislamiento & purificación , Investigación Biomédica Traslacional/tendencias , Investigación Biomédica/métodos , Investigación Biomédica/tendencias , COVID-19/epidemiología , Contención de Riesgos Biológicos/métodos , Citometría de Flujo/métodos , Humanos , Difusión de la Información/métodos , Investigación Biomédica Traslacional/métodos
4.
Nat Methods ; 14(9): 865-868, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28759029

RESUMEN

High-throughput single-cell RNA sequencing has transformed our understanding of complex cell populations, but it does not provide phenotypic information such as cell-surface protein levels. Here, we describe cellular indexing of transcriptomes and epitopes by sequencing (CITE-seq), a method in which oligonucleotide-labeled antibodies are used to integrate cellular protein and transcriptome measurements into an efficient, single-cell readout. CITE-seq is compatible with existing single-cell sequencing approaches and scales readily with throughput increases.


Asunto(s)
Mapeo Epitopo/métodos , Epítopos/inmunología , Perfilación de la Expresión Génica/métodos , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Análisis de Secuencia de ARN/métodos , Análisis de Matrices Tisulares/métodos , Transcriptoma/fisiología
6.
Cytometry A ; 89(5): 461-71, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26990501

RESUMEN

Modern flow cytometry systems can be coupled to plate readers for high-throughput acquisition. These systems allow hundreds of samples to be analyzed in a single day. Quality control of the data remains challenging, however, and is further complicated when a large number of parameters is measured in an experiment. Our examination of 29,228 publicly available FCS files from laboratories worldwide indicates 13.7% have a fluorescence anomaly. In particular, fluorescence measurements for a sample over the collection time may not remain stable due to fluctuations in fluid dynamics; the impact of instabilities may differ between samples and among parameters. Therefore, we hypothesized that tracking cell populations (which represent a summary of all parameters) in centered log ratio space would provide a sensitive and consistent method of quality control. Here, we present flowClean, an algorithm to track subset frequency changes within a sample during acquisition, and flag time periods with fluorescence perturbations leading to the emergence of false populations. Aberrant time periods are reported as a new parameter and added to a revised data file, allowing users to easily review and exclude those events from further analysis. We apply this method to proof-of-concept datasets and also to a subset of data from a recent vaccine trial. The algorithm flags events that are suspicious by visual inspection, as well as those showing more subtle effects that might not be consistently flagged by investigators reviewing the data manually, and out-performs the current state-of-the-art. flowClean is available as an R package on Bioconductor, as a module on the free-to-use GenePattern web server, and as a plugin for FlowJo X. © 2016 International Society for Advancement of Cytometry.


Asunto(s)
Algoritmos , Citometría de Flujo/normas , Rastreo Celular/instrumentación , Rastreo Celular/métodos , Conjuntos de Datos como Asunto , Fluorescencia , Humanos , Control de Calidad
7.
Trends Immunol ; 33(7): 323-32, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22476049

RESUMEN

In recent years, advances in technology have provided us with tools to quantify the expression of multiple genes in individual cells. The ability to measure simultaneously multiple genes in the same cell is necessary to resolve the great diversity of cell subsets, as well as to define their function in the host. Fluorescence-based flow cytometry is the benchmark for this; with it, we can quantify 18 proteins per cell, at >10 000 cells/s. Mass cytometry is a new technology that promises to extend these capabilities significantly. Immunophenotyping by mass spectrometry provides the ability to measure >36 proteins at a rate of 1000 cells/s. We review these cytometric technologies, capable of high-content, high-throughput single-cell assays.


Asunto(s)
Citofotometría/métodos , Animales , Supervivencia Celular , Citofotometría/economía , Citofotometría/instrumentación , Humanos
8.
J Virol ; 87(3): 1779-88, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23175378

RESUMEN

Coinfection with Plasmodium falciparum malaria and Epstein-Barr virus (EBV) is a major risk factor for endemic Burkitt lymphoma (eBL), still one of the most prevalent pediatric cancers in equatorial Africa. Although malaria infection has been associated with immunosuppression, the precise mechanisms that contribute to EBV-associated lymphomagenesis remain unclear. In this study, we used polychromatic flow cytometry to characterize CD8(+) T-cell subsets specific for EBV-derived lytic (BMFL1 and BRLF1) and latent (LMP1, LMP2, and EBNA3C) antigens in individuals with divergent malaria exposure. No malaria-associated differences in EBV-specific CD8(+) T-cell frequencies were observed. However, based on a multidimensional analysis of CD45RO, CD27, CCR7, CD127, CD57, and PD-1 expression, we found that individuals living in regions with intense and perennial (holoendemic) malaria transmission harbored more differentiated EBV-specific CD8(+) T-cell populations that contained fewer central memory cells than individuals living in regions with little or no (hypoendemic) malaria. This profile shift was most marked for EBV-specific CD8(+) T-cell populations that targeted latent antigens. Importantly, malaria exposure did not skew the phenotypic properties of either cytomegalovirus (CMV)-specific CD8(+) T cells or the global CD8(+) memory T-cell pool. These observations define a malaria-associated aberration localized to the EBV-specific CD8(+) T-cell compartment that illuminates the etiology of eBL.


Asunto(s)
Linfocitos T CD8-positivos/inmunología , Coinfección/inmunología , Infecciones por Virus de Epstein-Barr/inmunología , Herpesvirus Humano 4/patogenicidad , Malaria Falciparum/epidemiología , Malaria Falciparum/inmunología , Plasmodium falciparum/patogenicidad , África/epidemiología , Niño , Preescolar , Infecciones por Virus de Epstein-Barr/complicaciones , Citometría de Flujo , Humanos , Lactante , Malaria Falciparum/complicaciones , Subgrupos de Linfocitos T/inmunología
10.
Cytometry A ; 85(12): 1037-48, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25346474

RESUMEN

Much of the complexity of multicolor flow cytometry experiments lies within the development of antibody staining panels and the standardization of instruments. In this article, we propose a theoretical metric and describe how measurements of sensitivity and resolution can be used to predict the success of panels, and ensure that performance across instruments is standardized (i.e., inter-instrument standardization). Sensitivity can be determined by summing two major contributors of background, background originating from the instrument (optical noise and electronic noise) and background due to the experimental conditions (i.e., Raman scatter, and spillover spreading arising from other fluorochromes in the panel). The former we define as Bcal and the latter we define as Bsos . The combination of instrument and experiment background is defined as Btot . Importantly, the Btot will affect the degree of panel separation, therefore the greater the degree of Btot the lower the separation potential. In contrast, resolution is a measure of separation between populations. Resolution is directly proportional to the number of photoelectrons generated per molecule of excited fluorochrome and is known as the "Q" value. Q and Btot values can be used to define the performance of each detector on an instrument and together they can be used to calculate a separation index. Hence, detectors with known Q and Btot values can be used to evaluate panel success based on the detector specific separation index. However, the current technologies do not enable measurements of Q and Btot values for all parameters, but new technology to allow these measurements will likely be introduced in the near future. Nonetheless, Q and Btot measurements can aid in panel development, and reveal sources of instrument-to-instrument variation in panel performance. In addition, Q and B values can form the basis for a comprehensive and versatile quality assurance program.


Asunto(s)
Citometría de Flujo/instrumentación , Citometría de Flujo/normas , Citometría de Flujo/métodos , Humanos
11.
Methods Cell Biol ; 186: 249-270, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38705602

RESUMEN

Molecular cytometry refers to a group of high-parameter technologies for single-cell analysis that share the following traits: (1) combined (multimodal) measurement of protein and transcripts, (2) medium throughput (10-100K cells), and (3) the use of oligonucleotide-tagged antibodies to detect protein expression. The platform can measure over 100 proteins and either hundreds of targeted genes or the whole transcriptome, on a cell-by-cell basis. It is currently one of the most powerful technologies available for immune monitoring. Here, we describe the technology platform (which includes CITE-Seq, REAP-Seq, and AbSeq), provide guidance for its optimization, and discuss advantages and limitations. Finally, we provide some vignettes from studies that demonstrate the application and potential insight that can be gained from molecular cytometry studies.


Asunto(s)
Citometría de Flujo , Análisis de la Célula Individual , Humanos , Análisis de la Célula Individual/métodos , Citometría de Flujo/métodos , Perfilación de la Expresión Génica/métodos , Transcriptoma/genética , Animales
13.
Bioinformatics ; 28(7): 1009-16, 2012 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-22383736

RESUMEN

MOTIVATION: Polychromatic flow cytometry (PFC), has enormous power as a tool to dissect complex immune responses (such as those observed in HIV disease) at a single cell level. However, analysis tools are severely lacking. Although high-throughput systems allow rapid data collection from large cohorts, manual data analysis can take months. Moreover, identification of cell populations can be subjective and analysts rarely examine the entirety of the multidimensional dataset (focusing instead on a limited number of subsets, the biology of which has usually already been well-described). Thus, the value of PFC as a discovery tool is largely wasted. RESULTS: To address this problem, we developed a computational approach that automatically reveals all possible cell subsets. From tens of thousands of subsets, those that correlate strongly with clinical outcome are selected and grouped. Within each group, markers that have minimal relevance to the biological outcome are removed, thereby distilling the complex dataset into the simplest, most clinically relevant subsets. This allows complex information from PFC studies to be translated into clinical or resource-poor settings, where multiparametric analysis is less feasible. We demonstrate the utility of this approach in a large (n=466), retrospective, 14-parameter PFC study of early HIV infection, where we identify three T-cell subsets that strongly predict progression to AIDS (only one of which was identified by an initial manual analysis). AVAILABILITY: The 'flowType: Phenotyping Multivariate PFC Assays' package is available through Bioconductor. Additional documentation and examples are available at: www.terryfoxlab.ca/flowsite/flowType/ SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online. CONTACT: rbrinkman@bccrc.ca.


Asunto(s)
Biología Computacional/métodos , Citometría de Flujo , Infecciones por VIH/inmunología , Subgrupos de Linfocitos T/inmunología , Biomarcadores/análisis , Humanos , Inmunofenotipificación/métodos , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Subgrupos de Linfocitos T/citología
15.
Blood ; 117(18): 4805-15, 2011 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-21398582

RESUMEN

A highly complex network of coinhibitory and costimulatory receptors regulates the outcome of virus-specific CD8(+) T-cell responses. Here, we report on the expression patterns of multiple inhibitory receptors on HIV-specific, cytomegalovirus-specific, and bulk CD8(+) T-cell memory populations. In contrast to cytomegalovirus-specific CD8(+) T cells, the majority of HIV-specific CD8(+) T cells exhibited an immature phenotype and expressed Programmed Death-1, CD160 and 2B4 but not lymphocyte activation gene-3. Notably, before antiretroviral therapy, simultaneous expression of these negative regulators correlated strongly with both HIV load and impaired cytokine production. Suppression of HIV replication by antiretroviral therapy was associated with reduced surface expression of inhibitory molecules on HIV-specific CD8(+) T cells. Furthermore, in vitro manipulation of Programmed Death-1 and 2B4 inhibitory pathways increased the proliferative capacity of HIV-specific CD8(+) T cells. Thus, multiple coinhibitory receptors can affect the development of HIV-specific CD8(+) T-cell responses and, by extension, represent potential targets for new immune-based interventions in HIV-infected persons.


Asunto(s)
Linfocitos T CD8-positivos/inmunología , Infecciones por VIH/inmunología , Fármacos Anti-VIH/uso terapéutico , Antígenos CD/metabolismo , Proteínas Reguladoras de la Apoptosis/antagonistas & inhibidores , Proteínas Reguladoras de la Apoptosis/metabolismo , Antígeno B7-H1 , Linfocitos T CD8-positivos/metabolismo , Linfocitos T CD8-positivos/virología , Citomegalovirus/inmunología , Femenino , Proteínas Ligadas a GPI/metabolismo , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/metabolismo , Infecciones por VIH/virología , VIH-1/inmunología , Humanos , Memoria Inmunológica , Masculino , Receptor de Muerte Celular Programada 1 , Receptores Inmunológicos/antagonistas & inhibidores , Receptores Inmunológicos/metabolismo , Familia de Moléculas Señalizadoras de la Activación Linfocitaria , Subgrupos de Linfocitos T/inmunología , Subgrupos de Linfocitos T/metabolismo , Subgrupos de Linfocitos T/virología , Viremia/inmunología , Viremia/metabolismo , Proteína del Gen 3 de Activación de Linfocitos
16.
Methods ; 57(3): 251-8, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22391486

RESUMEN

Flow cytometry has been the premier tool for single cell analysis since its invention in the 1960s. It has maintained this position through steady advances in technology and applications, becoming the main force behind interrogating the complexities of the immune system. Technology development was a three-pronged effort, including the hardware, reagents, and analysis algorithms to allow measurement of as many as 20 independent parameters on each cell, at tens of thousands of cells per second. In the coming years, cytometry technology will integrate with other techniques, such as transcriptomics, metabolomics, and so forth. Ongoing efforts are aimed at algorithms to analyse these aggregated datasaets over large numbers of samples. Here we review the development efforts heralding the next stage of flow cytometry.


Asunto(s)
Citometría de Flujo/métodos , Citometría de Flujo/tendencias , Sistema Inmunológico/citología , Algoritmos , Color , Citometría de Flujo/instrumentación , Colorantes Fluorescentes , Predicción , Humanos , Procesamiento de Imagen Asistido por Computador , Sistema Inmunológico/inmunología , Análisis de la Célula Individual
17.
Nat Med ; 12(8): 972-7, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16862156

RESUMEN

Immune responses arise from a wide variety of cells expressing unique combinations of multiple cell-surface proteins. Detailed characterization is hampered, however, by limitations in available probes and instrumentation. Here, we use the unique spectral properties of semiconductor nanocrystals (quantum dots) to extend the capabilities of polychromatic flow cytometry to resolve 17 fluorescence emissions. We show the need for this power by analyzing, in detail, the phenotype of multiple antigen-specific T-cell populations, revealing variations within complex phenotypic patterns that would otherwise remain obscure. For example, T cells specific for distinct epitopes from one pathogen, and even those specific for the same epitope, can have markedly different phenotypes. The technology we describe, encompassing the detection of eight quantum dots in conjunction with conventional fluorophores, should expand the horizons of flow cytometry, as well as our ability to characterize the intricacies of both adaptive and innate cellular immune responses.


Asunto(s)
Citometría de Flujo/métodos , Inmunofenotipificación/métodos , Nanotecnología , Puntos Cuánticos , Complejo CD3/inmunología , Antígenos CD8/inmunología , Epítopos , Fluoresceína-5-Isotiocianato , Colorantes Fluorescentes , Antígenos HLA-DR/inmunología , Humanos , Complejo Mayor de Histocompatibilidad , Semiconductores , Linfocitos T/inmunología
18.
Front Immunol ; 14: 1067352, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36798126

RESUMEN

Hepato-pancreatico-biliary (HPB) malignancies are difficult-to-treat and continue to to have a high mortality and significant therapeutic resistance to standard therapies. Immune oncology (IO) therapies have demonstrated efficacy in several solid malignancies when combined with chemotherapy, whereas response rates in pancreatic ductal adenocarcinoma (PDA) are poor. While promising in hepatocellular carcinoma (HCC) and cholangiocarcinoma (CCA), there remains an unmet need to fully leverage IO therapies to treat HPB tumors. We therefore defined T cell subsets in the tumor microenvironment of HPB patients utilizing a novel, multiparameter flow cytometry and bioinformatics analysis. Our findings quantify the T cell phenotypic states in relation to checkpoint receptor expression. We demonstrate the presence of CD103+ tissue resident memory T cells (TRM), CCR7+ central memory T cells, and CD57+ terminally differentiated effector cells across all HPB cancers, while the anti-tumor function was dampened by expression of multiple co-inhibitory checkpoint receptors. Terminally exhausted T cells lacking co-stimulatory receptors were more prevalent in PDA, whereas partially exhausted T cells expressing both co-inhibitory and co-stimulatory receptors were most prevalent in HCC, especially in early stage. HCC patients had significantly higher TRM with a phenotype that could confer restored activation in response to immune checkpoint therapies. Further, we found a lack of robust alteration in T cell activation state or checkpoint expression in response to chemotherapy in PDA patients. These results support that HCC patients might benefit most from combined checkpoint therapies, whereas efforts other than cytotoxic chemotherapy will likely be necessary to increase overall T cell activation in CCA and PDA for future clinical development.


Asunto(s)
Neoplasias de los Conductos Biliares , Neoplasias del Sistema Biliar , Carcinoma Hepatocelular , Carcinoma Ductal Pancreático , Neoplasias Hepáticas , Neoplasias Pancreáticas , Humanos , Carcinoma Ductal Pancreático/tratamiento farmacológico , Carcinoma Ductal Pancreático/patología , Conductos Biliares Intrahepáticos/metabolismo , Microambiente Tumoral , Neoplasias Pancreáticas
20.
Lancet Haematol ; 10(5): e346-e358, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37011643

RESUMEN

BACKGROUND: Lymphomatoid granulomatosis is a rare Epstein-Barr virus-associated B-cell lymphoproliferative disorder with a median overall survival of less than 2 years. In this study, we hypothesised that low-grade lymphomatoid granulomatosis is immune-dependent and high-grade lymphomatoid granulomatosis is immune-independent. On the basis of this hypothesis, we investigated the activity and safety of new treatment with immunotherapy in patients with low-grade disease and standard chemotherapy in patients with high-grade disease. METHODS: In this open-label, single-centre, phase 2 trial, we enrolled patients aged 12 years or older with untreated, or relapsed or refractory lymphomatoid granulomatosis at the National Cancer Institute (National Institutes of Health, Bethesda, MD, USA). Patients with low-grade disease received dose-escalated interferon alfa-2b, starting at 7·5 million international units subcutaneously three times per week for up to 1 year past best response, and patients with high-grade disease received six cycles every 3 weeks of intravenous, dose-adjusted etoposide, prednisone, vincristine, cyclophosphamide, doxorubicin, and rituximab (DA-EPOCH-R). Starting doses were 50 mg/m2 per day as a continuous intravenous infusion from day 1 to day 4 (96 h) for etoposide; 60 mg/m2 twice daily by mouth from day 1 to day 5 for prednisone; 0·4 mg/m2 per day as a continuous intravenous infusion from day 1 to day 4 (96 h) for vincristine; 750 mg/m2 intravenous on day 5 for cyclophosphamide; 10 mg/m2 per day as a continuous intravenous infusion from day 1 to day 4 (96 h) for doxorubicin; and 375 mg/m2 intravenous on day 1 for rituximab. The doses of doxorubicin, etoposide, and cyclophosphamide were adjusted up or down on the basis of neutrophil and platelet nadirs. Patients with residual or progressive disease after initial therapy crossed over to alternative therapy. The primary endpoint was the proportion of patients who had an overall response and the 5-year progression-free survival after initial or cross-over treatment. Analysis of response included all participants who underwent restaging imaging; safety analysis included all patients who received any dose of study drugs. The trial is open for enrolment and is registered at ClinicalTrials.gov, NCT00001379. FINDINGS: 67 patients were enrolled between Jan 10, 1991, and Sept 5, 2019 (42 [63%] were male). 45 patients received initial treatment with interferon alfa-2b (16 of whom crossed over to DA-EPOCH-R) and 18 received initial treatment with DA-EPOCH-R (eight of whom crossed over to interferon alfa-2b); four underwent surveillance only. After initial treatment with interferon alfa-2b, the overall response was 64% (28 of 44 evaluable patients) with 61% (27 of 44) having a complete response, whereas, after cross-over treatment with interferon alfa-2b, the overall response was 63% (five of eight evaluable patients) with 50% (four of eight) having a complete response. After initial treatment with DA-EPOCH-R, the overall response was 76% (13 of 17 evaluable patients) with 47% (eight of 17) having a complete response, whereas, after cross-over treatment with DA-EPOCH-R, the overall response was 67% (ten of 15 evaluable patients) with 47% (seven of 15) having a complete response. 5-year progression-free survival was 48·5% (95% CI 33·2-62·1) after initial treatment with interferon alfa-2b, 50·0% (15·2-77·5) after cross-over treatment with interferon alfa-2b, 25·4% (8·2-47·2) after initial treatment with DA-EPOCH-R, and 62·5% (34·9-81·1) after cross-over treatment with DA-EPOCH-R. The most common grade 3 or worse adverse events in patients treated with interferon alfa-2b included neutropenia (27 [53%] of 51 patients), lymphopenia (24 [47%]), and leukopenia (24 [47%]). The four most common grade 3 or worse adverse events in patients treated with DA-EPOCH-R included neutropenia (29 [88%] of 33 patients), leukopenia (28 [85%]), infection (18 [55%]), and lymphopenia (17 [52%]). Serious adverse events occurred in 13 (25%) of 51 patients receiving treatment with interferon alfa-2b and 21 (64%) of 33 patients receiving DA-EPOCH-R, with five treatment-related deaths: one thromboembolic, one infection, and one haemophagocytic syndrome with interferon alfa-2b, and one infection and one haemophagocytic syndrome with DA-EPOCH-R. INTERPRETATION: Interferon alfa-2b is efficacious for treating low-grade lymphomatoid granulomatosis and hence reducing progression to high-grade disease, whereas patients with high-grade lymphomatoid granulomatosis showed expected responses to chemotherapy. Uncontrolled immune regulation of Epstein-Barr virus is hypothesised to result in the emergence of low-grade disease after chemotherapy, for which treatment with interferon alfa-2b is efficacious. FUNDING: Intramural Research Programs of the National Cancer Institute and National Institute of Allergy and Infectious Diseases, National Institutes of Health.


Asunto(s)
Infecciones por Virus de Epstein-Barr , Linfohistiocitosis Hemofagocítica , Linfoma de Células B Grandes Difuso , Linfoma no Hodgkin , Granulomatosis Linfomatoide , Linfopenia , Neutropenia , Humanos , Masculino , Femenino , Vincristina/efectos adversos , Prednisona/uso terapéutico , Etopósido/uso terapéutico , Rituximab/efectos adversos , Interferón alfa-2/uso terapéutico , Infecciones por Virus de Epstein-Barr/inducido químicamente , Infecciones por Virus de Epstein-Barr/tratamiento farmacológico , Linfohistiocitosis Hemofagocítica/tratamiento farmacológico , Granulomatosis Linfomatoide/tratamiento farmacológico , Granulomatosis Linfomatoide/inducido químicamente , Linfoma de Células B Grandes Difuso/tratamiento farmacológico , Herpesvirus Humano 4 , Linfoma no Hodgkin/tratamiento farmacológico , Ciclofosfamida/efectos adversos , Doxorrubicina/efectos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Neutropenia/etiología , Linfopenia/inducido químicamente , Linfopenia/tratamiento farmacológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA