Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Environ Sci Technol ; 57(40): 15232-15242, 2023 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-37603422

RESUMEN

Breakpoint chlorination is prevalent in drinking water and potable reuse water treatment. Breakpoint chlorination enhances the formation of N-nitrosamines through reactions that form nitrosating agents. The most recent study suggests that nitroxyl (HNO) can react with free chlorine (HOCl) to form the nitrosyl chloride (ClNO) nitrosating agent but has not experimentally verified its importance in breakpoint chlorination. This study first assessed the formation of N-nitrosamines from model N-chloro-alkylamine precursors when they were added to a mixture of HOCl and HNO-derived nitrosating agents generated by chlorinating hydroxyurea. Results demonstrated negligible N-nitrosamine formation. Instead, we observed that the interaction of NCl3 with NHCl2 (total Cl2/total N molar ratio = 2.4-3:1) produced an intermediate capable of nitrosating N-chloro-alkylamines to N-nitrosamines at yields 8-fold higher to those observed in NHCl2 treatment alone, within a very short timescale (<3 min). We examined the stoichiometry of the reaction of NCl3 with NHCl2 using a UV-spectrum-based approach. Nitrosyl chloride was proposed as the key intermediate, likely formed alongside the reformation of NHCl2. Further isotopic experiments, byproduct measurements, and kinetic modeling supported the hypotheses. Modeling indicated that the reaction of NCl3 with NHCl2 explained ∼75% of NDMA formation during breakpoint chlorination. Because NCl3 is mainly derived from the reaction of HOCl with NHCl2, controlling NHCl2 (e.g., with additional treatment) is critical for minimizing nitrosamine formation in waters where breakpoint chlorination occurs.

2.
Int J Mol Sci ; 24(12)2023 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-37373510

RESUMEN

The diagnosis of liquid and solid biopsies by different instruments makes the clinic loading difficult in many aspects. Given the compositions of magnetic particles (MPs) with diverse characterizations and the innovative acoustic type of vibration sample magnetometer (VSM), the versatile, accessible magnetic diagnosis platform was proposed to meet clinical demands, such as low loading for multiple biopsies. In liquid biopsies of alpha-fetoprotein (AFP) standard solutions and subject serums, molecular concentration was analyzed from saturation magnetization by the soft type of Fe3O4 MPs with AFP bioprobe coating. In the phantom mixture simulated as bounded MPs in tissue, the bounded MPs was evaluated from the area of the hysteresis loop by hard type of cobalt MPs without bio-probes coating. Not only a calibration curve was founded for many hepatic cell carcinoma stages, but also microscale images verified the Ms increase due to magnetic protein clusters, etc. Hence, its wide populations in clinics could be expected.


Asunto(s)
Neoplasias Hepáticas , alfa-Fetoproteínas , Humanos , Magnetismo , Neoplasias Hepáticas/diagnóstico , Fenómenos Magnéticos , Biopsia
3.
Biomed Eng Online ; 21(1): 38, 2022 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-35715781

RESUMEN

BACKGROUND: Although the powerful clinical effects of radiofrequency and microwave ablation have been established, such ablation is associated with several limitations, including a small ablation size, a long ablation time, the few treatment positioning, and biosafety risks. To overcome these limitations, biosafe and efficient magnetic ablation was achieved in this study by using biocompatible liquid gallium as an ablation medium and a contrast medium for imaging. RESULTS: Magnetic fields with a frequency (f) lower than 200 kHz and an amplitude (H) × f value lower than 5.0 × 109 Am-1 s-1 were generated using the proposed method. These fields could generate an ablation size of 3 cm in rat liver lobes under a temperature of approximately 300 °C and a time of 20 s. The results of this study indicate that biomedical gallium can be used as a contrast medium for the positioning of gallium injections and the evaluation of ablated tissue around a target site. Liquid gallium can be used as an ablation medium and imaging contrast medium because of its stable retention in normal tissue for at least 3 days. Besides, the high anticancer potential of gallium ions was inferred from the self-degradation of 100 µL of liquid gallium after around 21 days of immersion in acidic solutions. CONCLUSIONS: The rapid wireless ablation of large or multiple lesions was achieved through the simple multi-injection of liquid gallium. This approach can replace the currently favoured procedure involving the use of multiple ablation probes, which is associated with limited benefits and several side effects. METHODS: Magnetic ablation was confirmed to be highly efficient by the consistent results obtained in the simulation and in vitro tests of gallium and iron oxide as well as the electromagnetic specifics and thermotherapy performance comparison detailed in this study Ultrasound imaging, X-ray imaging, and magnetic resonance imaging were found to be compatible with the proposed magnetic ablation method. Self-degradation analysis was conducted by mixing liquid gallium in acidic solutions with a pH of approximately 5-7 (to imitate a tumour-containing microenvironment). X-ray diffraction was used to identify the gallium oxides produced by degraded gallium ions.


Asunto(s)
Técnicas de Ablación , Ablación por Catéter , Galio , Animales , Galio/farmacología , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Ratas , Ultrasonografía
4.
Sensors (Basel) ; 22(22)2022 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-36433573

RESUMEN

The objective of the proposed human-machine cooperation (HMC) workstation is to both rapidly detect calcium-based fish bones in masses of minced fish floss and visually guide operators in approaching and removing the detected fish bones by hand based on the detection of fingernails or plastic-based gloves. Because vibration is a separation mechanism that can prevent absorption or scattering in thick fish floss for UV fluorescence detection, the design of the HMC workstation included a vibration unit together with an optical box and display screens. The system was tested with commonly used fish (swordfish, salmon, tuna, and cod) representing various cooking conditions (raw meat, steam-cooked meat, and fish floss), their bones, and contaminating materials such as derived from gloves made of various types of plastic (polyvinylchloride, emulsion, and rubber) commonly used in the removal of fish bones. These aspects were each investigated using the spectrum analyzer and the optical box to obtain and analyze the fluorescence spectra and images. The filter was mounted on a charge-coupled device, and its transmission-wavelength window was based on the characteristic band for fish bones observed in the spectra. Gray-level AI algorithm was utilized to generate white marker rectangles. The vibration unit supports two mechanisms of air and downstream separation to improve the imaging screening of fish bones inside the considerable flow of fish floss. Notably, under 310 nm ultraviolet B (UVB) excitation, the fluorescence peaks of the raw fillets, steam-cooked meat, and fish floss were observed at for bands at longer wavelengths (500-600 nm), whereas those of the calcium and plastic materials occurred in shorter wavelength bands (400-500 nm). Perfect accuracy of 100% was achieved with the detection of 20 fish bones in 2 kg of fish floss, and the long test time of around 10-12 min results from the manual removal of these fish bones.


Asunto(s)
Calcio , Vibración , Animales , Humanos , Fluorescencia , Vapor , Peces , Tecnología , Plásticos
6.
Micromachines (Basel) ; 13(10)2022 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-36295958

RESUMEN

Ablation is a clinical cancer treatment, but some demands are still unsatisfied, such as electromagnetic interferences amongst multiple ablation needles during large tumour treatments. This work proposes a physical synthesis for composite particles of biocompatible iron oxide particles and liquid metal gallium (Ga) with different alternative-current (AC)-magnetic-field-induced heat mechanisms of magnetic particle hyperthermia and superior resistance heat. By some imaging, X-ray diffraction, and vibrating sample magnetometer, utilised composite particles were clearly identified as the cluster of few iron oxides using the small weight ratio of high-viscosity liquid metal Ga as conjugation materials without surfactants for physical targeting of limited fluidity. Hence, well penetration inside the tissue and the promotion rate of heat generation to fit the ablation requirement of at least 60 °C in a few seconds are achieved. For the injection and the post-injection magnetic ablations, the volume variation ratios of mice dorsal tumours on Day 12 were expressed at around one without tumour growth. Its future powerful potentiality is expected through a percutaneous injection.

7.
Biosensors (Basel) ; 11(10)2021 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-34677319

RESUMEN

Infections of orchids by the Odontoglossum ringspot virus or Cymbidium mosaic virus cause orchid disfiguration and are a substantial source of economic loss for orchid farms. Although immunoassays can identify these infections, immunoassays are expensive, time consuming, and labor consuming and limited to sampling-based testing methods. This study proposes a noncontact inspection platform that uses a spectrometer and Android smartphone. When orchid leaves are illuminated with a handheld optical probe, the Android app based on the Internet of Things and artificial intelligence can display the measured florescence spectrum and determine the infection status within 3 s by using an algorithm hosted on a remote server. The algorithm was trained on optical data and the results of polymerase chain reaction assays. The testing accuracy of the algorithm was 89%. The area under the receiver operating characteristic curve was 91%; thus, the platform with the algorithm was accurate and convenient for infection screening in orchids.


Asunto(s)
Orchidaceae , Teléfono Inteligente , Inteligencia Artificial , Enfermedades de las Plantas/virología , Reacción en Cadena de la Polimerasa , Potexvirus , Tobamovirus
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA