Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Am Coll Cardiol ; 30(1): 19-26, 1997 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-9207616

RESUMEN

OBJECTIVES: We sought to obtain a noninvasive estimation of mean pulmonary wedge pressure (MPWP) in patients with chronic atrial fibrillation (AF). BACKGROUND: It has previously been demonstrated that MPWP can be reliably estimated from Doppler indexes of mitral and pulmonary venous flow (PVF) in patients with sinus rhythm. Doppler estimation of MPWP has not been validated in patients with AF. METHODS: MPWP was correlated with variables of mitral and pulmonary venous flow velocity as assessed by Doppler transthoracic echocardiography in 35 consecutive patients. The derived algorithm was prospectively tested in 23 additional patients. RESULTS: In all patients the mitral flow pattern showed only a diastolic forward component. A significant but relatively weak correlation (r = -0.50) was observed between MPWP and mitral deceleration time. In 12 (34%) of 35 patients, the pulmonary vein flow tracing demonstrated only a diastolic forward component; a diastolic and late systolic forward flow was noted in the remaining 23 patients (66%). A strong negative correlation was observed between MPWP and the normalized duration of the diastolic flow (r = -0.80) and its initial deceleration slope time (r = -0.91). Deceleration time > 220 ms predicted MPWP < or = 12 mm Hg with 100% sensitivity and 100% specificity. When estimating MPWP by using the equation MPWP = -94.261 PVF deceleration time -9.831 Interval QRS to onset of diastolic PVF -16.337 Duration of PVF + 44.261, the measured and predicted MPWP closely agreed with a mean difference of -0.85 mm Hg. The 95% confidence limits were 4.8 and -6.1 mm Hg. CONCLUSIONS: In patients with chronic AF, MPWP can be estimated from transthoracic Doppler study of PVF velocity signals.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Válvula Mitral/diagnóstico por imagen , Válvula Pulmonar/diagnóstico por imagen , Presión Esfenoidal Pulmonar , Factores de Edad , Anciano , Anciano de 80 o más Años , Enfermedad Crónica , Factores de Confusión Epidemiológicos , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ultrasonografía Doppler de Pulso
2.
Am J Cardiol ; 74(6): 590-5, 1994 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-8074043

RESUMEN

The aim of this study was to assess the comparative diagnostic value of transesophageal echocardiography (TEE) and retrograde aortography for morphologic evaluation and anatomic mapping of aortic dissection. Seventy patients (aged 18 to 79 years) were prospectively evaluated with both techniques for suspected aortic dissection. In 64 patients, findings on aortography and TEE could be validated against intraoperative (n = 53) and postmortem (n = 11) findings. Examination time was significantly shorter for TEE (9 +/- 6 vs 48 +/- 25 minutes; p < 0.001). For the detection of aortic dissection, aortography showed lower sensitivity (87.5% vs 97.5%) and negative predictive value (85.3% vs 96.7%; both trends did not reach statistical significance) due mostly to the inability to identify noncommunicating dissection (dissection without intimal tears). For the epiphenomena of aortic dissection, aortography was significantly more accurate (97.2% vs 78%; p < 0.05) in assessing the site of entry, and TEE was more accurate in identifying thrombus formation (90% vs 65%; p < 0.05). There was no significant difference between aortography and TEE with regard to assessing secondary tears, aortic regurgitation, coronary dissection, and extension of the dissection. Thus, both TEE and aortography offer detailed anatomic mapping for guided surgical interventions. In elective patients, integration of both techniques seems the best approach; in unstable patients, TEE may be preferential because it is less invasive, requires no contrast injection, and provides accurate diagnosis in a short time at the bedside.


Asunto(s)
Aneurisma de la Aorta Torácica/diagnóstico , Disección Aórtica/diagnóstico , Aortografía , Ecocardiografía Transesofágica , Adulto , Anciano , Disección Aórtica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aortografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
3.
Chest ; 109(2): 562-3, 1996 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-8620738

RESUMEN

A 47-year-old man experienced recurrent pulmonary embolism resistant to aggressive medical and surgical prophylaxis. Although paraneoplastic hypercoagulability was suspected, no endoscopic or radiologic signs of malignancy were detected. Death was the result of electromechanical dissociation, which was attributed to right ventricular outflow obstruction. At autopsy, anaplastic lung carcinoma was found in the left basal segment with superimposed pulmonary infarction. A huge pedunculated thrombus was attached to the left ventricular apex and extended into the ascending aorta, obstructing the left ventricular outflow. To our knowledge, this is the first case of electromechanical dissociation due to left ventricular thrombus in a patient with pulmonary embolism. Radiologic and echocardiographic evaluation of such patients should take into account possible masking of the underlying neoplasm by embolic or hemorrhagic phenomena, or both, and the presence of left-sided cardiac thombi, which may cause catastrophic events.


Asunto(s)
Arritmias Cardíacas/etiología , Sistema de Conducción Cardíaco , Embolia Pulmonar/complicaciones , Obstrucción del Flujo Ventricular Externo/complicaciones , Arritmias Cardíacas/fisiopatología , Carcinoma/complicaciones , Resultado Fatal , Cardiopatías/complicaciones , Humanos , Neoplasias Pulmonares/complicaciones , Masculino , Persona de Mediana Edad , Embolia Pulmonar/fisiopatología , Recurrencia , Trombosis/complicaciones
4.
Heart ; 75(3): 301-6, 1996 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8800997

RESUMEN

OBJECTIVE: To assess the diagnostic potential of transthoracic and transoesophageal echocardiography for the detection of traumatic cardiovascular injuries in patients suffering from severe blunt chest trauma. DESIGN: Prospective study over a three year period. SETTING: A regional cardiothoracic centre. PATIENTS: 134 consecutive patients (94 M/40 F; mean age 38 (SD 14) years) suffering from severe blunt chest trauma (injury severity score 33.5 (18.2)). Most patients (89%) were victims of motor vehicle accidents. EVALUATION: All patients underwent transthoracic and transoesophageal echocardiography within 8 h of admission. Aortography was performed in the first 20 patients and in a further five equivocal cases. RESULTS: Transthoracic echocardiography provided suboptimal images in 83 patients, detecting three aortic ruptures, 28 pericardial effusions (one cardiac tamponade), 35 left pleural effusions, and 15 myocardial contusions. Transoesophageal echocardiography was feasible in 131 patients and detected 14 aortic ruptures (13 at the isthmus), 40 pericardial effusions, 51 left pleural effusions, 34 periaortic haematomas, 45 myocardial contusions, right atrial laceration in one patient with cardiac tamponade, one tricuspid valve rupture, and one severe mitral regurgitation caused by annular disruption. For the detection of aortic rupture transoesophageal echocardiography showed 93% sensitivity, 98% specificity, and 98% accuracy. Time to surgery was significantly shorter (30 (12) v 71 (21) min; P < 0.05) for patients operated on only on the basis of transoesophageal echocardiographic findings. CONCLUSIONS: Transthoracic echocardiography has low diagnostic yield in severe blunt chest trauma, while transoesophageal echocardiography provides accurate diagnosis in a short time at the bedside, is inexpensive, minimally invasive, and does not interfere with other diagnostic or therapeutic procedures.


Asunto(s)
Sistema Cardiovascular/lesiones , Ecocardiografía Transesofágica , Ecocardiografía , Lesiones Cardíacas/diagnóstico por imagen , Traumatismos Torácicos/diagnóstico por imagen , Heridas no Penetrantes/diagnóstico por imagen , Accidentes de Tránsito , Adolescente , Adulto , Anciano , Rotura de la Aorta/diagnóstico por imagen , Aortografía , Sistema Cardiovascular/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
5.
Heart ; 81(6): 621-7, 1999 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10336922

RESUMEN

AIM: To visualise the characteristics of ruptured plaques by intravascular ultrasound (IVUS) and to correlate plaque characteristics with clinical symptoms to establish a quantitative index of plaque vulnerability. METHODS: 144 consecutive patients with angina were examined using IVUS. Ruptured plaques, characterised by a plaque cavity and a tear on the thin fibrous cap, were identified in 31 patients (group A), of whom 23 (74%) presented with unstable angina. Plaque rupture was confirmed by injecting contrast medium filling the plaque cavity during IVUS examination. Of the patients without plaque rupture (group B, n = 108), only 19 (18%) had unstable angina. RESULTS: No significant differences were found between groups A and B in relation to plaque and vessel area (p > 0.05). Mean (SD) per cent stenosis in group A was less than in group B, at 56.2 (16.5)% v 67.9 (13.4)%; p < 0.001. Area of the emptied plaque cavity in group A (4.1 (3.2) mm2) was larger than the echolucent zone in group B (1.32 (0.79) mm2) (p < 0.001). The plaque cavity to plaque ratio in group A (38.5 (17.1)%) was larger than the echolucent area to plaque ratio in group B (11.2 (8.9)%) (p < 0.001). The thickness of the fibrous cap in group A was less than in group B, at 0.47 (0.20) mm v 0.96 (0.94) mm; p < 0.001. CONCLUSIONS: Plaques seem to be prone to rupture when the echolucent area is larger than 4.1 (3.2) mm2, when the echolucent area to plaque ratio is greater than 38.5 (17.1)%, and when the fibrous cap is thinner than 0.7 mm. IVUS can identify plaque rupture and vulnerable plaques. This may influence patient management and treatment.


Asunto(s)
Angina Inestable/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Adulto , Anciano , Angina Inestable/etiología , Calcio/análisis , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Factores de Riesgo , Rotura Espontánea/diagnóstico por imagen , Ultrasonografía Intervencional
6.
Int J Cardiol ; 37(2): 253-6, 1992 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-1452384

RESUMEN

A 25-yr-old female who had undergone surgery for common atrium and atrioventricular septal defect at the age of 9, was found to have residual shunting at the level of the atrioventricular junction. Precordial echocardiography failed to assess the direction of the shunt. Transesophageal echocardiography showed dehiscence of the atrial patch at the level of the atrioventricular junction. Through this defect left-atrium-to right ventricle shunting occurred in diastole, whereas in systole the defect was closed by the juxtaposition of the anterior tricuspid valve leaflet.


Asunto(s)
Ecocardiografía , Cardiopatías Congénitas/cirugía , Defectos del Tabique Interatrial/cirugía , Defectos del Tabique Interventricular/cirugía , Hemodinámica/fisiología , Complicaciones Posoperatorias/diagnóstico por imagen , Dehiscencia de la Herida Operatoria/diagnóstico por imagen , Adulto , Velocidad del Flujo Sanguíneo , Ecocardiografía Doppler , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interventricular/diagnóstico por imagen , Humanos , Pericardio/trasplante , Técnicas de Sutura
7.
Int J Cardiol ; 38(3): 309-14, 1993 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8463013

RESUMEN

In order to widen the diagnostic capability of single-plane transesophageal echocardiography, which has been so far confined to transverse imaging planes, we obtained four transgastric longitudinal echocardiographic views which have not been previously described. These views can image structures such as superior and inferior vena cava, the right ventricular inflow and outflow tract, the mitral apparatus and the ascending aorta, which are poorly visualized by transesophageal transverse single-plane echocardiography. Among 400 consecutive patients these scans gave relevant additional diagnostic information in 62 cases (15.5%) and provided the correct diagnosis in 37 (9.2%). There were no complications related to the longer gastric manipulation of the probe and the quality of the images was high. We conclude that longitudinal echotomographic scanning of the heart is not exclusively confined to the use of biplane or omniplane probes, but longitudinal views can be consistently obtained with a single-plane instrument.


Asunto(s)
Ecocardiografía/métodos , Aorta/diagnóstico por imagen , Femenino , Atrios Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Estómago , Venas Cavas/diagnóstico por imagen
8.
Int J Cardiol ; 31(2): 223-33, 1991 May.
Artículo en Inglés | MEDLINE | ID: mdl-1869332

RESUMEN

To determine the utility of transesophageal echocardiographic monitoring during percutaneous balloon mitral valvotomy, we analyzed data from 40 consecutive patients who had been randomly assigned to undergo balloon mitral valvotomy under transesophageal echocardiographic guidance or without echo. All procedures were carried out under general anaesthesia. The completion rate (100% vs 73%), the procedure time (108 +/- 28 min vs 65 +/- 18 min), the X-ray exposure time (62 +/- 13 vs 33 +/- 12 min), resulted significantly (P less than 0.001) more favorable in the echo-monitored patients. Moreover, a lower rate of major complications (cardiac tamponade, large residual atrial shunting, and severe mitral regurgitation) was noted in the echo-monitored patients. The achieved final area of the mitral valve did not differ significantly between the two groups. From an evaluation of results as a whole, 96% of the echo-monitored procedures were successful, whereas only 40% of the procedures conducted without echocardiographic control achieved a satisfactory final result in absence of major complications. We conclude that transesophageal echocardiography is a safe, effective, and valuable tool to monitor each step of balloon mitral valvotomy in order to shorten the time of the procedure, and to improve the results of this complex interventional catheterization technique.


Asunto(s)
Oclusión con Balón , Cateterismo , Ecocardiografía Doppler/métodos , Estenosis de la Válvula Mitral/terapia , Adulto , Anciano , Cateterismo/efectos adversos , Esófago , Femenino , Humanos , Masculino , Persona de Mediana Edad , Distribución Aleatoria
9.
J Heart Valve Dis ; 5(6): 656-61, 1996 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8953444

RESUMEN

BACKGROUND AND AIMS OF THE STUDY: Pericardial xenografts were introduced for clinical use following evidence of their good hemodynamic characteristics in laboratory tests; however, their efficiency in comparison with porcine valves has not been fully assessed. Pericarbon, a new type of pericardial bioprosthesis, has been recently developed in order to provide better hemodynamic performances and longer durability than such bioprostheses currently in use. METHODS: Fifteen patients operated on for aortic valve replacement with a 23 mm Pericarbon and a sex- and age-matched group operated on with a 23 mm Hancock II bioprosthesis were submitted to echocardiographic and Doppler examinations in order to compare the hemodynamic performance of the two devices. RESULTS: Peak transvalvular gradients for Pericarbon and Hancock II bioprostheses (38.9 +/- 13.0 vs. 33.9 +/- 13.0 mmHg; p = 0.294) and mean transvalvular gradients (24.7 +/- 7.6 vs. 20.8 +/- 9.9 mmHg, p = 0.24) showed no significant difference. However, the indexed effective prosthetic dynamic area was significantly larger for the Hancock II device (0.73 +/- 0.14 vs. 0.62 +/- 0.13 cm2; p < 0.05). CONCLUSIONS: When installed as 23 mm pericardial bioprostheses, the Pericarbon device appears not to demonstrate superior hemodynamic performance to that of the Hancock II; however, additional studies are needed to provide a definitive conclusion.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica/fisiología , Anciano , Aorta , Ecocardiografía , Ecocardiografía Doppler , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
10.
Chronobiol Int ; 14(4): 397-407, 1997 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-9262875

RESUMEN

The purpose was to assess age-related circadian changes of blood pressure profile (BPP) employing a truncated Fourier series with four harmonics (tFs) in patients with essential hypertension. The study was performed on 32 patients with essential hypertension divided in two groups: (A) 15 patients younger than 55 years and (B) 17 patients older than 60 years. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were monitored every 20 minutes for 24 h with a noninvasive portable device (SpaceLabs 90202). To evaluate the existence of SBP and DBP circadian rhythms a one-sample runs-test was performed and the mesor, amplitude, and acrophase from the overall curve of each patient were obtained by tFs. In both groups, SBP and DBP profiles showed a first peak in the late morning and a second peak in the early evening around the same hours. The two peaks in the SBP profile were higher and the two peaks in the DBP profile were lower in older patients than in younger ones (p < .01, p < .05, p < .3, p < .05). The truncated Fourier series with four harmonics evidences different age-related BP profiles characterized by two peaks with higher SBP and lower DBP in elderly patients. These changes of BPP are in accordance with the reported higher risk of cardiovascular events observed around the same hours.


Asunto(s)
Envejecimiento/fisiología , Presión Sanguínea/fisiología , Ritmo Circadiano/fisiología , Hipertensión/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades Cardiovasculares/etiología , Análisis de Fourier , Humanos , Hipertensión/complicaciones , Persona de Mediana Edad , Modelos Cardiovasculares , Factores de Riesgo
13.
Heart ; 91(3): 329-33, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15710712

RESUMEN

OBJECTIVE: To evaluate the comparative diagnostic value of harmonic imaging (HI) in the assessment of patients with suspected infective endocarditis (IE). SETTING: Tertiary referral centre. DESIGN: 139 consecutive patients were evaluated with three imaging modalities: transthoracic echocardiography with fundamental imaging (FI); HI; and transoesophageal echocardiography (TOE). Image quality was assessed for each modality by semiquantitative scoring (0, poor, to 3, excellent). Presence, dimension, and characteristics of vegetations were assessed separately for each imaging modality, as well as presence of abscesses. RESULTS: 35 patients had definite IE. TOE was positive in 33 patients, HI in 28, and FI in 12 (p < 0.001 for FI v HI and v TOE). Mean image quality was 1.4 (0.7) for FI, 2.1 (0.6) for HI (p < 0.01 v FI), and 2.6 (0.4) for TOE (p < 0.001 v HI). The association between FI and TOE findings was Phi = 0.35 (chi2 = 17.57, p = 0.0014) and between HI and TOE it was Phi = 0.95 (chi2 = 125.72, p < 0.0001; p < 0.0001 v FI). The global echo score of vegetations was 7.1 (3.3) with FI, 8.5 (3.4) with HI, and 11.3 (3.9) with TOE (p < 0.001 v HI). Compared with TOE, FI identified only one of seven abscesses (sensitivity 14%) and HI identified two of seven abscesses (sensitivity 28%). CONCLUSIONS: HI provides an accurate assessment of suspected IE. TOE achieves superior definition of IE related abnormalities.


Asunto(s)
Ecocardiografía/métodos , Endocarditis Bacteriana/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Femenino , Fiebre de Origen Desconocido/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
14.
BMJ Case Rep ; 2009: brc2007115840, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-21687324
15.
Int J Card Imaging ; 11(3): 201-3, 1995 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-7499910

RESUMEN

Transesophageal echocardiography (TEE) has been successfully used in monitoring complex or high-risk interventions in the cardiac catheterisation laboratory. We report a case in which biplane TEE was used to facilitate the biopsy of a mobile right atrial mass.


Asunto(s)
Biopsia/métodos , Ecocardiografía Transesofágica , Cardiopatías/patología , Trombosis/patología , Anciano , Diagnóstico Diferencial , Femenino , Atrios Cardíacos , Neoplasias Cardíacas/diagnóstico , Humanos
16.
G Ital Cardiol ; 18(11): 948-50, 1988 Nov.
Artículo en Italiano | MEDLINE | ID: mdl-2977768

RESUMEN

The authors report the case of a 57 year-old man with severe calcific aortic stenosis and single vessel coronary artery disease, symptomatic of angina pectoris, who refused surgical therapy and was treated with combined percutaneous aortic valvuloplasty and coronary angioplasty as a single procedure. Valvuloplasty was performed initially, and the calculated aortic valve area increased from 0.75 to 1.27 cm2. Subsequently, a 75% proximal right coronary artery stenosis was dilated to 20%. Two months later, at follow-up the patient was asymptomatic and the Doppler-determined aortic valve area was 1.01 cm2.


Asunto(s)
Angioplastia de Balón , Estenosis de la Válvula Aórtica/terapia , Cateterismo , Enfermedad Coronaria/terapia , Estenosis de la Válvula Aórtica/complicaciones , Enfermedad Coronaria/complicaciones , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
17.
Cardiology ; 79(2): 161-4, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1933968

RESUMEN

Emergency percutaneous balloon mitral valvotomy was carried out successfully in a 65-year-old woman with severe mitral stenosis and massive left atrial thrombosis. Transesophageal echocardiography was of great value in monitoring each step of the procedure in order to avoid systemic embolization due to improper manipulation of the dilating apparatus within the left atrium.


Asunto(s)
Ecocardiografía/métodos , Atrios Cardíacos , Estenosis de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Trombosis/complicaciones , Anciano , Procedimientos Quirúrgicos Cardíacos/métodos , Urgencias Médicas , Esófago , Femenino , Humanos , Estenosis de la Válvula Mitral/complicaciones , Monitoreo Fisiológico/métodos
18.
Am J Card Imaging ; 9(3): 174-9, 1995 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-7549357

RESUMEN

The echocardiographic characteristics of vegetation used by precordial echocardiography (PE) have been transferred unchanged to transesophageal echocardiography (TEE), which has different image definition and structural resolution. Twelve diagnostic criteria of vegetation were tested for their accuracy in 52 patients evaluated by PE and TEE for suspected endocarditis (36 men, 16 women; mean age, 62 +/- 18 years; 42 with proven endocarditis). Results of PE and TEE were validated against gross anatomic and histologic findings. Significant differences (P < .05) included the fact that TEE disclosed more vegetations not prolapsing in the subvalvular region and in absence of valvular regurgitation. At TEE vegetations presented motion distinct from the endocardial surface, irregular conformation, and uneven margins. Only chaotic motion was significantly associated with vegetations at PE; size < 0.5 cm and increased echogenicity characterized pseudovegetations at PE. Other features such as shaggy echoes or location out of the annular zone (previously indicated as typical of vegetations) were not significantly associated with infective lesions. Discriminant analysis of TEE characteristics of vegetations disclosed that chaotic motion was the variable most significantly (P = .008) associated with vegetation. Coexistence of this sign with size < 0.5 cm and uneven margins was associated with 93.3% sensitivity and 83.7% specificity. In conclusion, the echocardiographic aspect of vegetations is rather different when examined from the precordial and the transesophageal approach. Learning about pitfalls and normal variants should improve TEE specificity in the assessment of infective lesions.


Asunto(s)
Ecocardiografía Transesofágica , Ecocardiografía , Endocarditis Bacteriana/diagnóstico por imagen , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/microbiología , Análisis Discriminante , Ecocardiografía/métodos , Endocarditis Bacteriana/patología , Femenino , Humanos , Aumento de la Imagen , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/microbiología , Movimiento (Física) , Sensibilidad y Especificidad , Trombosis/patología , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/microbiología
19.
Cardiology ; 81(1): 54-8, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1477856

RESUMEN

Papillary muscle rupture occurred in two patients with recent inferior myocardial infarction. In one case with partial rupture transesophageal echocardiography in the standard four-chamber view did not visualize the rupture and in the second case with complete rupture it provided incomplete diagnostic information. A not previously described transgastric longitudinal scanning of the left ventricle provided complete delineation of the lesion and it was of great value in the diagnosis and management of this potentially lethal complication. Both patients were operated upon and had a favourable outcome.


Asunto(s)
Ecocardiografía/métodos , Rotura Cardíaca Posinfarto/diagnóstico por imagen , Músculos Papilares/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad
20.
G Ital Cardiol ; 21(11): 1205-16, 1991 Nov.
Artículo en Italiano | MEDLINE | ID: mdl-1809624

RESUMEN

The clinical, anatomic and functional features of 23 pts with congenital mitral valve malformation, seen at the University of Padua over a period of 10 years, are described. All pts underwent hemodynamic investigation and echo-Doppler evaluation. Diagnosis was confirmed at surgery in 17 cases, and at necropsy in six. In 9 pts mitral anomalies determined prevalent stenosis; the remaining 16 pts had moderate to severe mitral regurgitation. Associated cardiac malformations were present in 19 cases (82.6%). The clinical presentation occurred earlier in pts with mitral stenosis (16.9 months vs 6.55 years). The morphologic and echocardiographic features of each malformation are described. The term "valve dysplasia", as proposed by Becker et al to define the non-Ebstein malformations of the tricuspid valve, is herein applied to the congenital anomalies of the mitral valve in order to obtain a uniform and homogeneous approach to this vast spectrum of malformations.


Asunto(s)
Válvula Mitral/anomalías , Adolescente , Adulto , Niño , Preescolar , Cuerdas Tendinosas/anomalías , Ecocardiografía Doppler , Humanos , Lactante , Recién Nacido , Insuficiencia de la Válvula Mitral/etiología , Estenosis de la Válvula Mitral/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA