Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 565
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Phys Rev Lett ; 129(1): 011806, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35841544

RESUMEN

We report on the direct search for cosmic relic neutrinos using data acquired during the first two science campaigns of the KATRIN experiment in 2019. Beta-decay electrons from a high-purity molecular tritium gas source are analyzed by a high-resolution MAC-E filter around the end point at 18.57 keV. The analysis is sensitive to a local relic neutrino overdensity ratio of η<9.7×10^{10}/α (1.1×10^{11}/α) at a 90% (95%) confidence level with α=1 (0.5) for Majorana (Dirac) neutrinos. A fit of the integrated electron spectrum over a narrow interval around the end point accounting for relic neutrino captures in the tritium source reveals no significant overdensity. This work improves the results obtained by the previous neutrino mass experiments at Los Alamos and Troitsk. We furthermore update the projected final sensitivity of the KATRIN experiment to η<1×10^{10}/α at 90% confidence level, by relying on updated operational conditions.

2.
Phys Rev Lett ; 126(9): 091803, 2021 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-33750167

RESUMEN

We report on the light sterile neutrino search from the first four-week science run of the KATRIN experiment in 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are analyzed by a high-resolution MAC-E filter down to 40 eV below the endpoint at 18.57 keV. We consider the framework with three active neutrinos and one sterile neutrino. The analysis is sensitive to the mass, m_{4}, of the fourth mass state for m_{4}^{2}≲1000 eV^{2} and to active-to-sterile neutrino mixing down to |U_{e4}|^{2}≳2×10^{-2}. No significant spectral distortion is observed and exclusion bounds on the sterile mass and mixing are reported. These new limits supersede the Mainz results for m_{4}^{2}≲1000 eV^{2} and improve the Troitsk bound for m_{4}^{2}<30 eV^{2}. The reactor and gallium anomalies are constrained for 100<Δm_{41}^{2}<1000 eV^{2}.

3.
J Eur Acad Dermatol Venereol ; 35(3): 669-676, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33037671

RESUMEN

BACKGROUND: The Breslow depth is an important parameter to determine the excision margin and prognosis of melanoma. However, it is difficult to accurately determine the actual Breslow depth before surgery using the existing ocular micrometer and biopsy technique. OBJECTIVES: To evaluate the use of 3D wide-field multispectral photoacoustic imaging to non-invasively measure depth and outline the boundary of melanomas for optimal surgical margin selection. METHODS: Six melanoma patients were examined in vivo using the 3D multispectral photoacoustic imaging system. For five cases of melanomas (one in situ, three nodular, and one acral lentiginous type melanoma), the spectrally unmixed photoacoustic depths were calculated and compared against histopathological depths. RESULTS: Spectrally unmixed photoacoustic depths and histopathological depths match well within a mean absolute error of 0.36 mm. In particular, the measured minimum and maximum depths in the in situ and nodular type of melanoma were 0.6 and 9.1 mm, respectively. In the 3D photoacoustic image of one metastatic melanoma, feeding vessels were visualized in the melanoma, suggesting the neovascularization around the tumour. CONCLUSIONS: The 3D multispectral photoacoustic imaging not only provides well-measured depth and sizes of various types of melanomas, it also visualizes the metastatic type of melanoma. Obtaining accurate depth and boundary information of melanoma before surgery would play a useful role in the complete excision of melanoma during surgery.


Asunto(s)
Melanoma , Técnicas Fotoacústicas , Neoplasias Cutáneas , Diagnóstico por Imagen , Humanos , Melanoma/diagnóstico por imagen , Proyectos Piloto , Neoplasias Cutáneas/diagnóstico por imagen
4.
Osteoporos Int ; 31(9): 1713-1719, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32346772

RESUMEN

The magnitude of hip impact force during a fall on the ground (i.e., concrete surface) from standing height was determined. We found that this force decreases up to 59%, depending on how they land on the ground. INTRODUCTION: We determined the magnitude of hip impact force that humans may experience in the event of a fall from standing height on the ground, in order to examine how the hip impact force was affected by characteristics of a fall. METHODS: Twenty subjects mimicked a typical older adults' falls on a mat. Trials were acquired with three initial fall directions: forward, sideways, and backward. Trials were also acquired with three knee positions at the time of hip impact: knee together, knee on the mat, and free knee. During falls, attenuated vertical hip impact forces and corresponding depression of the mat were measured via a force plate placed under the mat and motion capture system, respectively. Using a mass-spring model, actual hip impact force and body stiffness during a fall on the ground were estimated. RESULTS: Hip impact force averaged 4.0 kN (SD = 1.7). The hip impact force was associated with knee condition (F = 25.6, p < 0.005), but not with fall direction (F = 0.4, p = 0.599). Compared with "knee on the mat," hip impact force averaged 59% and 45% greater in "free knee" and "knee together," respectively (4.6 versus 2.9 kN, p < 0.005; 4.3 versus 2.9 kN, p < 0.005). However, the hip impact force did not differ between "free knee" and "knee together (4.6 versus 4.3 kN, p = 0.554). CONCLUSION: Our results suggest that hip fracture risk during a fall decreases substantially, depending on how they land on the ground, informing the development of safe landing strategies to prevent fall-related hip fractures in older adults.


Asunto(s)
Accidentes por Caídas , Fracturas de Cadera , Anciano , Fenómenos Biomecánicos , Placas Óseas , Fracturas de Cadera/epidemiología , Fracturas de Cadera/etiología , Humanos , Articulación de la Rodilla
5.
Clin Radiol ; 75(11): 879.e1-879.e6, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32727657

RESUMEN

AIM: To evaluate the technical feasibility and safety of percutaneous recanalisation of benign postoperative hepaticojejunostomy strictures using the reverse end of a microwire. MATERIALS AND METHODS: Twenty-one patients with benign postoperative hepaticojejunostomy strictures that had failed to recanalise following management with conventional percutaneous techniques from January 2012 to March 2019 were included in the study. The stricture was punctured by the reverse end of a microwire. Subsequently, serial balloon dilatation and covered stent placement was performed. Technical as well as clinical success, complications, and patency of the hepaticojejunostomy were evaluated. RESULTS: Technical success was achieved in 19 of 21 (90.5%) patients. The mean number of treatment sessions was 1.2 (range, 1-2). The obstructive symptoms were resolved within 3 days after the procedure in 19 patients (100%). There were no major complications. The 1-year and 3-year patency rates were 76.9% and 61.5%, respectively. CONCLUSION: Percutaneous recanalisation using the reverse end of a microwire is technically feasible and safe in the treatment of benign postoperative hepaticojejunostomy strictures. This technique is useful when the conventional percutaneous technique cannot be used to cross the stricture.


Asunto(s)
Constricción Patológica/etiología , Enfermedades del Yeyuno/etiología , Yeyuno/diagnóstico por imagen , Yeyuno/cirugía , Hepatopatías/etiología , Hígado/cirugía , Páncreas/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos del Sistema Biliar/efectos adversos , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/cirugía , Femenino , Humanos , Enfermedades del Yeyuno/diagnóstico por imagen , Enfermedades del Yeyuno/cirugía , Hígado/diagnóstico por imagen , Hepatopatías/diagnóstico por imagen , Hepatopatías/cirugía , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
6.
BMC Anesthesiol ; 20(1): 32, 2020 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-32000680

RESUMEN

BACKGROUND: Performing spinal anaesthesia using the conventional popping method with a 27-gauge (27G) spinal needle is technically difficult. In this study, we compared the aspiration and conventional popping method for spinal anaesthesia using 27G Quincke-type needles. METHODS: This prospective, randomized study enrolled 90 patients, aged 19 to 65 years, with American Society of Anesthesiologists physical status I-III, who were undergoing spinal anaesthesia. Patients were randomly assigned to one of two groups using a computer-generated random number table: patients receiving spinal anaesthesia using the aspiration method, in which the needle is advanced with continuous aspiration, or the conventional popping method. The primary outcome measure was the success rate of the first attempt to perform dural puncture. Number of attempts and passages, withdrawal cases, successful attempt time, total procedure time, and actual depth of dural puncture were recorded. RESULTS: Eighty-eight patients were included in the study. In the aspiration group, the success rate of first attempt for dural puncture was 93.3%, compared with 72.1% in the popping group (P = 0.019). Success involving needle withdrawal was recorded in 4 (8.9%) patients in the aspiration group and 13 (30.2%) in the popping group (P = 0.024). In the popping group, the number of attempts was significantly higher (P = 0.044), and total procedure time was significantly longer (P = 0.023). Actual depths of dural puncture were deeper in the popping group than in the aspiration group (P = 0.019). CONCLUSIONS: The aspiration method using a 27G Quincke-type needle offers clinical benefits for dural puncture compared with the conventional popping method for spinal anaesthesia. TRIAL REGISTRATION: Clinical research information service number: KCT0002815, registered 21/Apr/2018. Retrospectively registered.


Asunto(s)
Anestesia Raquidea/instrumentación , Anestesia Raquidea/métodos , Punción Espinal/instrumentación , Punción Espinal/métodos , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Agujas , Estudios Prospectivos , Adulto Joven
7.
Opt Express ; 27(5): 6832-6841, 2019 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-30876260

RESUMEN

We report the transfer printing of GaN-based microscale vertical-type light-emitting diodes (µ-VLEDs) using a functional layer and a biomimetic stamp. An oxide-based functional layer is inserted onto the structure of a µ-VLED and used to separate the chip from the µ-VLED wafer by absorbing the pulse of a UV pulse laser during pick-up of the transfer printing process. Polydimethylsiloxane (PDMS)-based biomimetic stamps have been fabricated to mimic the gecko lizard cilia for improved adhesion and repeatability. The biomimetic stamp has an adhesion force of 25.6 N/cm2, which is 12 times the adhesion of a flat stamp; an adhesion force of 10 N/cm2 or more was maintained after 100,000 repeated adhesion tests. A flexible 10 × 10 prototype array on a polyimide substrate was fabricated, and its bending test results indicated that the strain effect on the forward voltage and the output power was less than 1%. The stable bending test results of the prototype indicate that µ-VLEDs using biomimetic stamps allow the necessary stability for practical transfer printing.

8.
Phys Rev Lett ; 123(22): 221802, 2019 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-31868426

RESUMEN

We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic end point at 18.57 keV gives an effective neutrino mass square value of (-1.0_{-1.1}^{+0.9}) eV^{2}. From this, we derive an upper limit of 1.1 eV (90% confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a factor of 2 and provides model-independent input to cosmological studies of structure formation.

9.
Nanotechnology ; 30(37): 374001, 2019 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-31181544

RESUMEN

A SrRuO3 thin film has been widely used as a metal electrode in electronic devices based on transition metal oxides, and hence it is important to understand its thermal transport properties to minimize a thermal degradation problem during the device operation. Using the time-domain thermoreflectance measurement technique, we investigate the cross-plane thermal conductivity of the SrRuO3 thin films with a thickness variation from 1 µm to 8 nm. We find that the thermal conductivity is reduced from about 6 W m-1 K-1 for the 1 µm thick film to about 1.2 W m-1 K-1 for the 8 nm thick film, and attribute this behavior to the boundary scattering of thermal carriers which originally have the mean free path of about 20 nm in a bulk state. Also, we observe a clear dip behavior of the thermal conductivity in the intermediate thickness around 30 nm which suggests an existence of a strong scattering source other than the film boundary. We explain this result by considering an additional interfacial scattering at the tetragonal-orthorhombic phase boundary which is formed during the strain relaxation with an increase of the film thickness.

10.
J Obstet Gynaecol ; 39(6): 833-839, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31006301

RESUMEN

The objective of this prospective cohort study was to evaluate the therapeutic efficacy and safety of ultrasound-guided high-intensity focussed ultrasound (HIFU) in the treatment of uterine fibroids. Twenty premenopausal women with symptomatic fibroids underwent ultrasound-guided HIFU therapy. Twenty-two fibroids with a median baseline volume of 127.0 cm3 (range 18.5-481.2 cm3) were treated. The percentages fibroid volume reduction were 46.9 (range -8.8-73.1) at 1-month, 57.4 (-51.5-95.2) at 3-month, 60.1 (-18.9-97.8) at 6-month and 75.9 (-33.7-99.3) at 12-month, after treatment. The modified Uterine Fibroid Symptom and Quality of Life (UFS-QOL) scores were reduced by 40.7% (0-59.3%) at 3-month, 45.5% (0-70.4%) at 6-month and 44.9% (0-71.4%) at 12-month after treatment. Three patients required subsequent surgical interventions. No significant complications were encountered. Ultrasound-guided HIFU appears to be effective and safe for the treatment of symptomatic uterine fibroids in selected patients. Impact statement What is already known on this subject? Ultrasound-guided high-intensity focussed ultrasound (HIFU) is a relatively new uterine-sparing treatment for fibroids. Most clinical reports are from China, which suggest that this treatment is a safe and effective modality. However, in many other countries, HIFU treatment for fibroids, especially using ultrasound as image guidance, is still considered novel with limited clinical experience. What do the results of this study add? This preliminary report adds to our limited local experience on HIFU and provides reassurance on our continual utilisation of this treatment modality for fibroids. With the increasing demand of uterine-sparing alternatives, experiences shared among different countries are important to make this treatment modality generalisable and universally acceptable. What are the implications of these findings for clinical practice and/or further research?Ultrasound-guided HIFU (USgHIFU) can potential be offered as an alternative treatment modality for women with fibroids.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Leiomioma/cirugía , Neoplasias Uterinas/cirugía , Adulto , Estudios de Cohortes , Femenino , Humanos , Leiomioma/patología , Persona de Mediana Edad , Premenopausia , Estudios Prospectivos , Resultado del Tratamiento , Ultrasonografía , Neoplasias Uterinas/patología
11.
Br J Anaesth ; 121(5): 1115-1122, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30336856

RESUMEN

BACKGROUND: Sevoflurane and desflurane are widely used in balanced anaesthesia in combination with opioid analgesics. The opioid remifentanil is frequently chosen because of its extremely rapid pharmacokinetics. However, intraoperative high-dose remifentanil is associated with increased postoperative pain and rescue analgesic use owing to acute tolerance and opioid-induced hyperalgesia. This study aimed to compare intraoperative remifentanil requirements during equi-minimum alveolar concentration (MAC) sevoflurane and desflurane anaesthesia via surgical pleth index-guided remifentanil administration. METHODS: Eighty-two subjects undergoing laparoscopic cholecystectomy were randomly allocated to two groups receiving either sevoflurane (n=40) or desflurane (n=42). Anaesthesia was maintained with the assigned inhaled anaesthetics and remifentanil. End-tidal anaesthetic concentration was maintained at age-corrected 1.0 MAC, and remifentanil infusion was continuously adjusted to achieve a surgical pleth index of 20-50. Mean remifentanil infusion rate, which was the primary outcome of the study, was calculated as the total infused remifentanil dose per kg body weight per minute of total operative time. RESULTS: Mean remifentanil infusion rate [mean (standard deviation)] was significantly higher in the sevoflurane group than in the desflurane group [0.192 (0.064) vs. 0.099 (0.033) µg kg-1 min-1; difference, 0.093 (95% confidence interval, 0.071-0.115); P<0.001]. CONCLUSIONS: During equi-MAC anaesthesia of 1.0 MAC, sevoflurane and desflurane did not show similar intraoperative remifentanil consumption under surgical pleth index-guided opioid administration. Further studies using other monitors with different measuring mechanisms are warranted to determine the cause of this difference. CLINICAL TRIAL REGISTRATION: NCT02830243 (ClinicalTrials.gov).


Asunto(s)
Analgesia/métodos , Anestésicos por Inhalación , Anestésicos Intravenosos , Desflurano , Remifentanilo , Sevoflurano , Adulto , Anciano , Algoritmos , Colecistectomía Laparoscópica/métodos , Monitores de Conciencia , Femenino , Humanos , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Adulto Joven
12.
Nutr Metab Cardiovasc Dis ; 28(11): 1106-1113, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30287123

RESUMEN

BACKGROUNDS AND AIMS: We aimed to reveal the association between subclinical inflammation and metabolic risk factors and to determine the difference in the association between normal-weight and obese Korean individuals. METHODS AND RESULTS: Data collected from the Korean National Health and Nutrition Examination Survey (KNHANES) 2015, conducted from January to December 2015, were analyzed. Overall, 4620 subjects were examined and divided into two subgroups: 2987 and 1633 subjects in the normal-weight and obese groups, respectively. The prevalence of obesity in the study population was 34.5% (n = 1633). After multivariate adjustment, impaired fasting glucose (IFG) (odds ratio [OR] 1.22, 95% confidence interval [CI] 1.05-1.42, P = 0.010), high triglyceride (TG) levels (OR 1.29, 95% CI 1.13-1.47, P < 0.001), and low high-density lipoprotein-cholesterol (HDL-C) levels (OR 1.47, 95% CI 1.31-1.64, P < 0.001) were significantly associated with increased high-sensitivity C-reactive protein (hs-CRP) levels in the normal-weight group but not in the obesity group. CONCLUSION: Subclinical inflammation was associated with IFG, high TG levels, and low HDL-C levels in normal-weight Korean individuals. Prospective and biochemical research is necessary to clarify the role of subclinical systemic inflammation in individuals with normal body weight and its impact on insulin resistance and abnormal lipid metabolism, which promote the incidence of metabolic syndrome and cardiovascular disease.


Asunto(s)
Dislipidemias/epidemiología , Trastornos del Metabolismo de la Glucosa/epidemiología , Inflamación/epidemiología , Enfermedades Asintomáticas , Biomarcadores/sangre , Glucemia/metabolismo , Proteína C-Reactiva/análisis , HDL-Colesterol/sangre , Estudios Transversales , Dislipidemias/sangre , Dislipidemias/diagnóstico , Femenino , Trastornos del Metabolismo de la Glucosa/sangre , Trastornos del Metabolismo de la Glucosa/diagnóstico , Humanos , Inflamación/sangre , Inflamación/diagnóstico , Mediadores de Inflamación/sangre , Resistencia a la Insulina , Masculino , Persona de Mediana Edad , Encuestas Nutricionales , Obesidad/diagnóstico , Obesidad/epidemiología , Prevalencia , República de Corea/epidemiología , Factores de Riesgo , Triglicéridos/sangre
13.
Clin Radiol ; 73(7): 665-671, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29622362

RESUMEN

AIM: To evaluate the safety and efficacy of repeated pelvic arterial embolisation (PAE) for uncontrolled postpartum haemorrhage (PPH) after a single session of PAE and to compare angiographic findings between the two sessions of PAE. MATERIALS AND METHODS: A total of 23 consecutive patients (age range, 23-44 years) who underwent repeated PAE for uncontrolled PPH between March 2001 and January 2016 in Severance Hospital were reviewed. The interval times between the two sessions of PAE, the angiographic findings, embolic materials, arteries embolised during PAE, and the clinical outcomes were reviewed retrospectively. RESULTS: Overall clinical success was achieved after repeated PAE in 21 of 23 patients (91.3%). There were no procedure-related, major complications. On angiography, active bleeding from the uterine collateral arteries was more frequently observed in the second session of PAE (p>0.05), and embolisation of the anterior division of the internal iliac artery was significantly higher during the second session of PAE. Use of permanent embolic materials was significantly higher during the second session of PAE. Recanalisation of a previously embolised artery was identified in 14 patients (60.9%) during the second session. CONCLUSION: Repeated PAE is safe and effective for managing recurrent bleeding after a single session of PAE. Repeated PAE is related to a higher chance of embolisation of the anterior division of the internal iliac artery, with the use of permanent embolic materials. Recanalisation of a previously embolised artery seems to be a principal source of rebleeding during a repeated session of PAE.


Asunto(s)
Embolización Terapéutica/métodos , Pelvis/irrigación sanguínea , Hemorragia Posparto/terapia , Adulto , Femenino , Humanos , Arteria Ilíaca , Masculino , Embarazo , Retratamiento , Estudios Retrospectivos , Resultado del Tratamiento , Arteria Uterina , Adulto Joven
14.
Osteoarthritis Cartilage ; 25(3): 401-405, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27477830

RESUMEN

OBJECTIVE: Lipocalin-2 (LCN2) is a recently characterized adipokine that is upregulated in chondrocytes treated with pro-inflammatory mediators and in the synovial fluid of osteoarthritis (OA) patients. Here, we explored the in vivo functions of LCN2 in OA cartilage destruction in mice. METHODS: The expression levels of LCN2 were determined at the mRNA and protein levels in primary cultured mouse chondrocytes and in human and mouse OA cartilage. Experimental OA was induced in wild-type (WT) or Lcn2-knockout (KO) mice by destabilization of the medial meniscus (DMM) or intra-articular (IA) injection of adenoviruses expressing hypoxia-inducible factor (HIF)-2α (Ad-Epas1), ZIP8 (Ad-Zip8), or LCN2 (Ad-Lcn2). The effect of LCN2 overexpression on the cartilage of WT mice was examined by IA injection of Ad-Lcn2. RESULTS: LCN2 mRNA levels in chondrocytes were markedly increased by the pro-inflammatory cytokines, interleukin (IL)-1ß and tumor necrosis factor-α (TNF-α), and by previously identified catabolic regulators of OA, such as HIF-2α and components of the zinc-ZIP8-MTF1 axis. LCN2 protein levels were also markedly increased in human OA cartilage and cartilage from various experimental mouse models of OA. However, overexpression of LCN2 in chondrocytes did not modulate the expression of cartilage matrix molecules or matrix-degrading enzymes. Furthermore, LCN2 overexpression in mouse cartilage via IA injection of Ad-Lcn2 did not cause OA pathogenesis, and Lcn2 KO mice showed no alteration in DMM-induced OA cartilage destruction. CONCLUSIONS: Our observations collectively suggest that upregulation of LCN2 in OA cartilage is not sufficient or necessary for OA cartilage destruction in mice.


Asunto(s)
Cartílago/metabolismo , Lipocalina 2/metabolismo , Osteoartritis/metabolismo , Animales , Cartílago/patología , Condrocitos/metabolismo , Humanos , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Osteoartritis/patología , Regulación hacia Arriba
15.
Spinal Cord ; 55(6): 601-605, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28117330

RESUMEN

STUDY DESIGN: Retrospective study. OBJECTIVES: To report the successful tracheostomy decannulation/extubation in cervical spinal cord injury (C-SCI) patients. SETTING: Tertiary university hospital, pulmonary rehabilitation center. METHODS: Complete or sensory incomplete C-SCI patients who had received invasive acute phase respiratory management, and succeeded in decannulation/extubation became candidates of this study. Retrospective review was conducted on the transitions of the respiratory status. RESULTS: Sixty-two patients (M: 55, F: 7) were identified. Traumatic etiologies accounted for 93.5%, and mean onset age was 47.6±15.8 years. Sixty patients (96.8%) had undergone tracheostomy and the other two received endotracheal intubation during acute phase. All patients succeeded in decannulation/extubation after employing mechanically assisted coughing and noninvasive mechanical ventilation (NIV). Mean time since tracheostomy to decannulation was 7.0±14.5 months. Of the 60 tracheostomized patients, 12 succeeded in decannulation without applying long-term NIV, 31 switched to continuous NIV after decannulation. Fifteen patients totally weaned off from ventilators after NIV. Two patients who once succeeded in decannulation were re-tracheostomized. For the 31 patients with continuous NIV, mean hours of daily need for ventilatory support had reduced from 15.3±8.0 to 5.7±5.7 h at final follow-ups. CONCLUSION: Complete or sensory incomplete C-SCI patients, even with high neurological level can be successfully decannulated through NIV and aggressive use of mechanically assisted coughing. Undesirable tracheostomy can be avoided by employing the noninvasive respiratory management.


Asunto(s)
Extubación Traqueal , Intubación , Traumatismos de la Médula Espinal/terapia , Traqueostomía , Vértebras Cervicales , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pruebas de Función Respiratoria , Estudios Retrospectivos , Resultado del Tratamiento
16.
Osteoarthritis Cartilage ; 24(12): 2153-2161, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27421775

RESUMEN

OBJECTIVE: SIRT1 has anti-inflammatory as well as protective effects in chondrocytes. The object of this study was to investigate whether microRNA-449a regulates expression of SIRT1, which inhibits expression of catabolic genes in IL-1ß-induced cartilage destruction. MATERIALS AND METHODS: MicroRNA-449a expression was determined in OA chondrocytes and IL-1ß-induced chondrocytes by real-time PCR. MicroRNA-449a binding sites on the 3'-UTR of SIRT1 mRNA and binding site conservation were examined using microRNA target prediction tools. SIRT1-overexpressing or knockdown chondrocytes were transfected with microRNA-449a or anti-microRNA-449a mimic and stimulated by IL-1ß. Expression of catabolic and anabolic genes was examined by real-time PCR and western blotting. Finally, positive effects of anti-microRNA-449a on expression of these genes were confirmed by western analysis of OA chondrocytes. RESULTS: Expression of microRNA-449a was increased in OA chondrocytes and IL-1ß-induced chondrocytes. MMP-13 expression was enhanced, whereas type II collagen and SIRT1 expression were decreased in IL-1ß-induced chondrocytes. SIRT1 overexpression resulted in decreased expression of catabolic genes such as MMPs and ADAMTSs in response to IL-1ß, but these effects were moderated by microRNA-449a. Suppression of microRNA-449a by anti-microRNA-449a inhibited expression of catabolic genes despite IL-1ß stimulation, but these effects were abolished in SIRT1 knockdown chondrocytes. Furthermore, expression of catabolic genes was decreased and expression of type II collagen as well as SIRT1 was restored by anti-microRNA-449a in OA chondrocytes as well as in IL-1ß-induced chondrocytes. CONCLUSION: Silencing of microRNA-449a had a protective effect, inhibiting catabolic gene expression and restoring anabolic gene expression, by targeting SIRT1 in IL-1ß-induced cartilage destruction.


Asunto(s)
Cartílago , Células Cultivadas , Condrocitos , Humanos , Interleucina-1beta , MicroARNs
17.
Phys Rev Lett ; 116(21): 211801, 2016 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-27284648

RESUMEN

The RENO experiment has analyzed about 500 live days of data to observe an energy dependent disappearance of reactor ν[over ¯]_{e} by comparing their prompt signal spectra measured in two identical near and far detectors. In the period between August of 2011 and January of 2013, the far (near) detector observed 31 541 (290 775) electron antineutrino candidate events with a background fraction of 4.9% (2.8%). The measured prompt spectra show an excess of reactor ν[over ¯]_{e} around 5 MeV relative to the prediction from a most commonly used model. A clear energy and baseline dependent disappearance of reactor ν[over ¯]_{e} is observed in the deficit of the observed number of ν[over ¯]_{e}. Based on the measured far-to-near ratio of prompt spectra, we obtain sin^{2}2θ_{13}=0.082±0.009(stat)±0.006(syst) and |Δm_{ee}^{2}|=[2.62_{-0.23}^{+0.21}(stat)_{-0.13}^{+0.12}(syst)]×10^{-3} eV^{2}.

18.
J Nanosci Nanotechnol ; 16(2): 1541-4, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27433617

RESUMEN

Titanium as one kind of biomaterials comes in direct contact with the body, making evaluation of biocompatibility an important aspect to biomaterials development. Surface chemistry of titanium plays an important role in osseointegration. Different surface modification alters the surface chemistry and result in different biological response. In this study, three kinds of mixed acid solutions were used to treat Ti specimens to induce Ca-P formation. Following a strong mixed acid activation process, Ca-P coating successfully formed on the Ti surfaces in simulated body fluid. Strong mixed acid increased the roughness of the metal surface, because the porous and rough surface allows better adhesion between Ca-P coatings and substrates. After modification of titanium surface by mixed acidic solution and subsequently H2O2/HCL treatment evaluation of biocompatibility was conducted from hydroxyapatite formation by biomimetic process and cell viability on modified titanium surface. Nano-scale modification of titanium surfaces can alter cellular and tissue responses, which may benefit osseointegration and dental implant therapy. Results from this study indicated that surface treatment methods affect the surface morphology, type of TiO2 layer formed and subsequent apatite deposition and biological responses. The thermo scientific alamarblue cell viability assay reagent is used to quantitatively measure the viability of mammalian cell lines, bacteria and fungi by incorporating a rapid, sensitive and reliable fluorometric/colorimetric growth indicator, without any toxic and side effect to cell line. In addition, mixed acid treatment uses a lower temperature and shorter time period than widely used alkali treatment.


Asunto(s)
Aleaciones/química , Apatitas/metabolismo , Osteoblastos/metabolismo , Titanio/química , Línea Celular , Humanos , Osteoblastos/citología , Propiedades de Superficie
19.
Anaesthesia ; 71(6): 692-9, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26954669

RESUMEN

Continuous interscalene block is an approved modality for postoperative pain control, but it may cause hemidiaphragmatic paresis. In this study we aimed to determine whether continuous supraclavicular block would provide postoperative analgesia comparable to that of continuous interscalene block and reduce the incidence of hemidiaphragmatic paresis. Patients scheduled for open rotator cuff repair were randomly allocated to receive continuous interscalene (n = 38) or supraclavicular block (n = 37). Both participants and assessing clinicians were blinded to the group allocation. The primary endpoint was the mean pain intensity 24 h after the surgery. Postoperative mean (SD) pain scores at 24 h were similar in the supraclavicular and interscalene groups (2.57 (1.71) vs 2.84 (1.75) respectively; p = 0.478). The incidence of complete or partial hemidiaphragmatic paresis was lower in the supraclavicular group at 1 h after admission to the postanaesthetic care unit and 24 h after the surgery [25 (68%) vs 38 (100%); p = 0.001 and 14 (38%) vs 27 (71%) respectively; p = 0.008]. Continuous supraclavicular block provided comparable analgesia compared with interscalene block with a reduced incidence of complete or partial hemidiaphragmatic paresis for 24 h following surgery.


Asunto(s)
Bloqueo del Plexo Braquial/métodos , Dolor Postoperatorio/prevención & control , Manguito de los Rotadores/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
20.
Int J Clin Pract ; 70(4): 302-11, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26997458

RESUMEN

AIM: The aim of this study was to assess the effects of ursodeoxycholic acid composite (URSA-S) on fatigue in patients with elevated liver function tests and/or fatty liver disease. METHODS: In this multi-centre randomised double-blinded placebo-controlled trial, 168 adults who were diagnosed with fatigue based on our criteria and had elevated liver function tests (but not > 5 times the normal level) and/or fatty liver on ultrasonography, were randomised to either the placebo or URSA-S administration group. The rate of improvement of checklist individual strength (CIS) using a cut-off of 76 points at the end of the study (8 weeks), the change in fatigue scale [CIS score and visual analogue scale (VAS)] were evaluated. The adverse effects of URSA-S were also recorded. RESULTS: The rate of CIS improvement at the end-point was 79.76% and 45.68% in the therapy and placebo groups, respectively (p < 0.05). The fatigue recovery rate of the CIS score and VAS were higher in the therapy (-25.44 ± 18.57, -27.84 ± 2.70) than in the placebo group (-16.59 ± 17.29, -19.46 ± 2.81) (p < 0.05). The difference in fatigue recovery rate between the therapy and placebo groups was significant after 8 weeks. When analysed separately in patients with abnormal liver function tests and fatty liver disease, the fatigue recovery rate of the CIS score and VAS at 8 weeks was higher in the therapy than in the placebo group (p < 0.05). The frequency of adverse events in the therapy group was not significantly higher than that in the placebo group. CONCLUSION: URSA-S is effective for alleviating fatigue in patients with liver dysfunction and/or fatty liver. The adverse effects of URSA-S are not significant. This study is registered at https://clinicaltrials.gov/ct2/show/NCT02415777.


Asunto(s)
Fatiga/tratamiento farmacológico , Hígado/metabolismo , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Ácido Ursodesoxicólico/uso terapéutico , Adulto , Colagogos y Coleréticos/uso terapéutico , Método Doble Ciego , Fatiga/etiología , Fatiga/metabolismo , Femenino , Estudios de Seguimiento , Humanos , Pruebas de Función Hepática , Masculino , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/tratamiento farmacológico , Enfermedad del Hígado Graso no Alcohólico/metabolismo , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA