Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Molecules ; 23(10)2018 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-30360416

RESUMEN

An efficient Ag/pyridine co-mediated oxidative arylthiocyanation of activated alkenes via radical addition/cyclization cascade process was developed. This reaction could be carried out under mild conditions to provide biologically interesting 3-alkylthiocyanato-2-oxindoles in good to excellent yields. Mechanistic studies suggested a unique NCS• radical addition path and clarified the dual roles of catalytic pyridine as base and crucial ligand to accelerate the oxidation of Ag(I) to Ag(II), which is likely oxidant responsible for the formation of NCS• radical. These mechanistic results may impact the design and refinement of other radical based reactions proceeding through catalytic oxidations mediated by Ag(I)-pyridine/persulfate. The chemical versatility of thiocyanate moiety was also highlighted via SCN-tailoring chemistry in post-synthetic transformation for new S-C(sp³/sp²/sp), S-P, and S-S bonds constructions. The protocol provides an easy access to many important bioisosteres in medicinal chemistry and an array of sulfur-containing 2-oxindoles that are difficult to prepare by other approaches.


Asunto(s)
Alquenos/química , Piridinas/química , Plata/química , Tiocianatos/química , Espectroscopía de Resonancia Magnética , Estructura Molecular , Oxidación-Reducción
2.
Ann Occup Hyg ; 60(3): 348-60, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26585828

RESUMEN

OBJECTIVE: The purpose of this study was to compare thermal desorption tubes and stainless steel canisters for measuring volatile organic compounds (VOCs) emitted from petrochemical factories. METHODS: Twelve petrochemical factories in the Mailiao Industrial Complex were recruited for conducting the measurements of VOCs. Thermal desorption tubes and 6-l specially prepared stainless steel canisters were used to simultaneously perform active sampling of environmental air samples. The sampling time of the environmental air samples was set up on 6 h close to a full work shift of the workers. A total of 94 pairwise air samples were collected by using the thermal adsorption tubes and stainless steel canisters in these 12 factories in the petrochemical industrial complex. To maximize the number of comparative data points, all the measurements from all the factories in different sampling times were lumped together to perform a linear regression analysis for each selected VOC. Pearson product-moment correlation coefficient was used to examine the correlation between the pairwise measurements of these two sampling methods. A paired t-test was also performed to examine whether the difference in the concentrations of each selected VOC measured by the two methods was statistically significant. RESULTS: The correlation coefficients of seven compounds, including acetone, n-hexane, benzene, toluene, 1,2-dichloroethane, 1,3-butadiene, and styrene were >0.80 indicating the two sampling methods for these VOCs' measurements had high consistency. The paired t-tests for the measurements of n-hexane, benzene, m/p-xylene, o-xylene, 1,2-dichloroethane, and 1,3-butadiene showed statistically significant difference (P-value < 0.05). This indicated that the two sampling methods had various degrees of systematic errors. Looking at the results of six chemicals and these systematic errors probably resulted from the differences of the detection limits in the two sampling methods for these VOCs. CONCLUSIONS: The comparison between the concentrations of each of the 10 selected VOCs measured by the two sampling methods indicted that the thermal desorption tubes provided high accuracy and precision measurements for acetone, benzene, and 1,3-butadiene. The accuracy and precision of using the thermal desorption tubes for measuring the VOCs can be improved due to new developments in sorbent materials, multi-sorbent designs, and thermal desorption instrumentation. More applications of thermal desorption tubes for measuring occupational and environmental hazardous agents can be anticipated.


Asunto(s)
Monitoreo del Ambiente/instrumentación , Acero Inoxidable , Compuestos Orgánicos Volátiles/análisis , Acetona/análisis , Contaminantes Atmosféricos/análisis , Benceno/análisis , Butadienos/análisis , Industria Química , Monitoreo del Ambiente/métodos , Sustancias Peligrosas/análisis , Humanos , Exposición Profesional/análisis , Xilenos/análisis
3.
Saf Health Work ; 15(2): 228-235, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39035801

RESUMEN

Background: Glove reuse poses risks, as chemicals can persist even after cleaning. Decontamination methods like thermal aeration, recommended by US OSHA, vary in effectiveness. Some studies show promising results, while others emphasize the importance of considering both permeation and tensile strength changes. This research advocates for informed glove reuse, emphasizing optimal thermal aeration temperatures and providing evidence to guide users in maintaining protection efficiency. Methods: The investigation evaluated Neoprene and Nitrile gloves (22 mils). Permeation tests with toluene and acetone adhered to American Society for Testing Materials (ASTM) F739 standards. Decontamination optimization involved aeration at various temperatures. The experiment proceeded with a maximum of 22 re-exposure cycles. Tensile strength and elongation were assessed following ASTM D 412 protocols. Breakthrough time differences were statistically analyzed using t-test and ANOVA. Results: At room temperature, glove residuals decreased, and standardized breakthrough time (SBT)2 was significantly lower than SBT1, indicating reduced protection. Higher temperature decontamination accelerated residual removal, with ΔSBT (SBT2/SBT1) exceeding 100%, signifying restored protection. Tensile tests showed stable neoprene properties postdecontamination. Results underscore thermal aeration's efficacy for gloves reuse, emphasizing temperature's pivotal role. Findings recommend meticulous management strategies, especially post-breakthrough, to uphold glove-protective performance. Conclusions: Thermal aeration at 100°C for 1 hour proves effective, restoring protection without compromising glove strength. The study, covering twenty cycles, suggests safe glove reuse with proper decontamination, reducing costs significantly. However, limitations in chemical-glove combinations and exclusive focus on specific gloves caution against broad generalization. The absence of regulatory directives on glove reuse highlight the importance of informed selection and rigorous decontamination validation for workplace safety practices.

4.
Arch Med Sci ; 11(2): 267-73, 2015 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-25995740

RESUMEN

INTRODUCTION: To investigate the association of the interleukin-1ß (IL-1ß) (3953/4) C→T polymorphism with chronic periodontitis (CP) in Asians. MATERIAL AND METHODS: Systematic searches of electronic databases and hand searching of references were performed, including PubMed, Embase, the Cochrane Library, and the Chinese National Knowledge Infrastructure (CNKI). Odds ratios (ORs) with 95% confidence intervals (CIs) were used to assess the strength of the associations. Publication bias was tested by Egger's test. Sensitivity analysis was conducted by limiting the meta-analysis studies conforming to Hardy-Weinberg equilibrium (HWE). Data analyses were carried out using RevMan 6.0. RESULTS: A meta-analysis was performed on 20 published case-control studies, including 1,656 CP cases and 1,498 healthy controls. The pooled OR was 1.60 (95% CI = 1.02-2.52, p = 0.04) for the T allele carriers (TT + CT) compared with CC and 1.60 (95% CI = 1.06-2.42, p = 0.02) for T vs. C. Subgroup analysis by country revealed significant risks of CP among Indians carrying the T allele (TT vs. CC: OR = 3.88, 95% CI = 1.77-8.50, p = 0.0007). CONCLUSIONS: The analysis showed that IL-1ß (3953/4) C→T polymorphism probably increases the risk of CP in Asians, and the IL-1ß+3954 TT genotype may be associated with a strongly increased risk of CP in Indians, but not in Chinese.

5.
Ultrason Sonochem ; 21(1): 395-400, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23972326

RESUMEN

The catalytic esterification of sodium 4-hydroxybenzoate with benzyl bromide by ultrasound-assisted solid-liquid phase-transfer catalysis (U-SLPTC) was investigated using the novel dual-site phase-transfer catalyst 4,4'-bis(tributylammoniomethyl)-1,1'-biphenyl dichloride (BTBAMBC), which was synthesized from the reaction of 4,4'-bis(chloromethyl)-1,1'-biphenyl and tributylamine. Without catalyst and in the absence of water, the product yield at 60 °C was only 0.36% in 30 min of reaction even under ultrasound irradiation (28 kHz/300 W) and 250 rpm of stirring speed. When 1cm(3) of water and 0.5 mmol of BTBAMBC were added, the yield increased to 84.3%. The catalytic intermediate 4,4'-bis(tributylammoniomethyl)-1,1'-biphenyl di-4-hydroxybenzoate was also synthesized to verify the intrinsic reaction which was mainly conducted in the quasi-aqueous phase locating between solid and organic phases. Pseudo-first-order kinetic equation was used to correlate the overall reaction, and the apparent rate coefficient with ultrasound (28 kHz/300 W) was 0.1057 min(-1), with 88% higher than that (0.0563 min(-1)) without ultrasound. The esterification under ultrasonic irradiation using BTBAMBC by solid-liquid phase-transfer catalysis was developed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA