Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros

Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39284939

RESUMEN

OBJECTIVES: Inner ear malformations (IEMs) may result in differences in outcomes of cochlear implant user. These differences could be observed in both behavioral and objective tests. eCAP is the most common used objective test in cochlear implants and have different presence rate in cochlear implant users with and without IEMs. This study aims to evaluate eCAP results from CI user with and without IEMs through different recoding methods; amplitude growth function, spreads of excitation and refractory recovery. METHODS: There were 42 CI users (20 IEM&22 normal) above five-years old and with at least one year experience. Three different eCAP measurement was conducted at several intracochlear electrodes. Presence rate, threshold levels and amplitude were compared between groups. RESULTS: For Amplitude growth function measurement, when the percentage of detected eCAP thresholds was analyzed between groups, there was a significant difference only for basal electrode and no significant difference for apical and middle electrodes. Similarly, the presence rate of RecF-eCAP for both groups were in a downward trend from apical to basal. However, there was no significant difference in AGF-eCAP and RecF-eCAP amplitudes between groups for the cochlea's apical, middle and basal region. Although the presence rate of SOE-eCAP was lower for IEM group, there was no significant difference in ECAP amplitudes for all maskers. CONCLUSIONS: It could be inferred that even though the observable eCAP rate differed between these two groups when the observable eCAP was recorded, the IEM group produced eCAP with similar amplitudes to normal cochlea group.

2.
Audiol Neurootol ; 28(3): 169-174, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36516739

RESUMEN

INTRODUCTION: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a viral infection with a wide variety of symptoms, including fever, coughing, sneezing, fatigue, and a loss of taste and smell. Moreover, there are some recent studies that investigate the effects of SARS-CoV-2 on hearing and auditory performance. With this current study, we investigate the early effects of the coronavirus disease on hair cells in the cochlea. METHODS: In the current study, there were 25 subjects (17 females, 8 males) who tested positive for polymerase chain reaction on nasopharyngeal swabs. They had reported normal auditory functions and no history of otology before SARS-CoV-2. To determine auditory functions, pure-tone audiometry, otoacoustic emissions (OAE) tests, and threshold equalizing noise (TEN) tests were used. RESULTS: Although the hearing thresholds increased at higher frequencies, they were within normal limits according to four-frequency pure-tone averages. All participants had normal OAE, and there were no detected dead regions for any of the subjects. Even so, there were significant increases in hearing thresholds in TEN. CONCLUSION: There is no cochlear dysfunction discovered by OAE and TEN in SARS-CoV-2-affected individuals. Nonetheless, the increase in hearing thresholds at higher frequencies, other than the pure-tone average frequencies detected by TEN, and the decrease in the presence of detected OAE could be related to deterioration in the basal part of the cochlea.


Asunto(s)
COVID-19 , SARS-CoV-2 , Masculino , Femenino , Humanos , Adulto , Umbral Auditivo , Cóclea , Audiometría de Tonos Puros , Emisiones Otoacústicas Espontáneas
3.
Am J Otolaryngol ; 44(1): 103679, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36334418

RESUMEN

OBJECTIVES: After auditory brainstem implant (ABI) surgery, stimulation of certain cranial nerves may result in a non-auditory response, and the electrodes that stimulate these nerves may be deactivated. The goals of this study are to compare the number of active electrodes in the initial activation and the last fitting, to investigate non-auditory response types and their frequency as a result of non-auditory stimulation, to compare the placements of deactivated electrodes as a result of non-auditory stimulation in the initial activation and the last fitting. METHODS: The computer software system was used to perform a retrospective analysis of the fitting data of 69 ABI users who underwent auditory brainstem implant surgery between January 1997 and January 2019. The non-auditory response types, deactive electrodes, and the positioning of the deactive electrodes horizontally and vertically were recorded in these users during the initial activation and the last fitting. RESULTS: There was no statistically significant difference between the number of active electrodes in the initial activation and the last fitting. The proportion of the users with deactive electrodes in the initial activation and the last fitting was not statistically significant different. In the horizontal and vertical placement classification, the placement of the deactive electrodes was not statistically different between initial activation and last fitting. The most common type of non-auditory response was facial nerve stimulation at the initial activation and no auditory perception at the last fitting. According to the difference between the number of active and deactive electrodes in the initial activation and the last fitting, as well as the auditory and non-auditory responses, it was found that the ABI users were statistically different between the initial activation and the last fitting. CONCLUSION: The results of this study show that not only auditory but also non-auditory responses occur in most ABI users. In addition, to the best of our knowledge, this study is the first to examine the frequencies of non-auditory response types, and the placement of the electrodes that cause these responses according to horizontal and vertical classifications.


Asunto(s)
Implantes Auditivos de Tronco Encefálico , Neurofibromatosis 2 , Humanos , Estudios Retrospectivos , Neurofibromatosis 2/cirugía , Estimulación Acústica , Percepción Auditiva , Potenciales Evocados Auditivos del Tronco Encefálico
4.
Eur Arch Otorhinolaryngol ; 280(12): 5299-5305, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37272952

RESUMEN

PURPOSE: This study aims to evaluate the everyday listening status of pediatric ABI users using the Turkish ABEL questionnaire. METHODS: The study included 33 parents of children with auditory brainstem implant, and 28 parents of children with cochlear implant were included as a control group. All implant users were between the ages of 4-14. Parents answered the ABEL questionnaire to assess their child's auditory behavior in their daily living environment. In addition, Categories of Auditory Performance (CAP) and Speech Intelligibility Rating (SIR) scales were used to evaluate speech perception and production. RESULTS: Auditory-aural, auditory awareness and ABEL total score of ABI users were statistically significantly lower than the CI group (p < 0.05). There was no statistically significant difference between the groups in the Conversational/Social skills subgroups. It was found that as the duration of ABI use increased, auditory-verbal, social skills and total scores increased significantly. In addition, correlations were obtained between ABEL total and subscale scores and CAP and SIR scores. CONCLUSIONS: Parents believe that their children adapt nicely to ABI and are aware of environmental sounds. This study reveals the auditory, aural, and social skills of children using ABI through the regards of their parents. This study showed that the ABEL questionnaire, which was used in previous studies to express parental views of children with hearing aids and cochlear implants, can also be used for parents of children using ABI.


Asunto(s)
Implantes Auditivos de Tronco Encefálico , Implantación Coclear , Implantes Cocleares , Sordera , Audífonos , Percepción del Habla , Niño , Humanos , Preescolar , Adolescente , Sordera/cirugía , Resultado del Tratamiento , Percepción Auditiva
5.
Cardiol Young ; 33(10): 2094-2100, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36911913

RESUMEN

Prolonged pleural effusion is a fairly common condition which has considerable impact on complicated and longer hospital stays after Fontan surgery. Identifying the patient population prone to have pleural effusions is still seeking for an answer. This study is to determine the variables that may predict prolonged pleural effusion according to the data of 69 patients who underwent Fontan operation between June 2018 and December 2020 and survived to date. Prolonged pleural effusion was defined as the need for a chest tube for more than 7 days. Two patient groups, with and without prolonged effusion, were compared in terms of pre-, peri-, and post-operative variables. The patients were subdivided into "high-risk" and "low-risk" groups based on the pre-operative catheterisation data. The most frequent main diagnosis was tricuspid atresia (n: 13, 19%). Among 69 patients, 28 (40%) had prolonged pleural effusion whereas 11 (16%) had effusions that lasted longer than 14 days. Ten patients among prolonged effusion group (35%) had pulmonary atresia coexistent with the main diagnosis. Fontan operation was performed in 6 patients (8.7%) over the age of 10, and 4 of these patients (67%) had prolonged pleural effusion. Among numerous variables, statistical significance between the two groups was achieved in pre-operative mean pulmonary artery pressure, post-operative albumin, C-reactive protein levels, length of hospital stay, duration of chest tube drainage, and amount of effusion per day. Early recognition and treatment strategies with routine medical protocol use remain to be the cornerstone for the management of post-operative prolonged pleural effusions after Fontan surgery.


Asunto(s)
Procedimiento de Fontan , Derrame Pleural , Atresia Tricúspide , Humanos , Procedimiento de Fontan/efectos adversos , Procedimiento de Fontan/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Derrame Pleural/diagnóstico , Derrame Pleural/etiología , Derrame Pleural/epidemiología , Atresia Tricúspide/complicaciones , Atresia Tricúspide/cirugía
6.
Clin Otolaryngol ; 46(1): 154-160, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32749771

RESUMEN

BACKGROUND AND OBJECTIVE: Inner ear malformations (IEMs) are common in children with hearing loss. The different types of IEMs form a unique subgroup of cochlear implant (CI) candidates. We aimed to evaluate the auditory perception outcomes of CI in children with different types of IEMs and compare them with CI users without IEMs. METHODS: The study included 274 CI users with and without IEMs as two groups (n = 137, each). Both groups' chronological age at implantation and duration of CI usage was matched (± 8 months). All subjects were evaluated pre-operatively and post-operatively by the Ling's sound test and the auditory perception test battery, which includes the Meaningful Auditory Integration Scale (MAIS), closed-set Pattern Perception Test (PPT) and open-set Sentence Recognition Test (SRT). Besides, children with IEMs were assessed for language development. RESULTS: Progress in the IEMs' group differed according to the type of ear anomaly. CI users with enlarged vestibular aqueduct had the highest scores, while users with common cavity had the lowest. Children with IEMs performed well on the closed-set test while having difficulty with the open-set test. CONCLUSION: Cochlear implantation outcomes are favourable in IEMs' patients with a cochlear nerve visible on magnetic resonance imaging. Our results indicate that it is critical to take the anatomical differences into account during follow-up and rehabilitation programmes. Each CI user should be evaluated according to his or her individual needs.


Asunto(s)
Percepción Auditiva/fisiología , Implantación Coclear , Implantes Cocleares , Oído Interno/anomalías , Trastornos de la Audición/terapia , Desarrollo del Lenguaje , Adolescente , Estudios de Casos y Controles , Niño , Preescolar , Estudios de Cohortes , Femenino , Trastornos de la Audición/diagnóstico , Trastornos de la Audición/etiología , Humanos , Masculino , Resultado del Tratamiento
7.
J Manipulative Physiol Ther ; 44(6): 445-454, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34456042

RESUMEN

OBJECTIVE: The aim of this study was to investigate the immediate effect of Mulligan sustained natural apophyseal glides (SNAGs) on muscular stiffness by using ultrasound shear wave elastography, pain, and function in patients with nonspecific low back pain. METHODS: In a prospective, randomized, controlled, double-blinded study, 30 participants with nonspecific low back pain were randomly divided into 2 groups: a real SNAG group (aged 21.0 ± 1.7, 5 men, 10 women) and sham SNAG group (aged 20.4 ± 0.5, 4 men, 11 women). Muscular stiffness of the multifidus and erector spinal muscles with ultrasound shear wave elastography, visual analog scale, the sit and reach, flamingo balance, the functional reach, side bridge, and Biering-Sorensen tests were made before and immediately after intervention. The Oswestry Disability Index score was recorded only baseline. RESULTS: After intervention, the change in visual analog scale, sit and reach, Biering-Sorensen, and side bridge tests scores were significantly different between real SNAG and sham SNAG groups (P < .05), but there was no significant difference in functional reach and flamingo balance test scores between the groups (P > .05). There was no significant difference for all measurements between pre- and post-intervention in sham SNAG group (P > .05). There was a significant reduction in muscular stiffness in the real SNAG group. But there was no change in muscular stiffness between pre- and postintervention in the sham group (P > .05). CONCLUSIONS: This study demonstrated that the Mulligan SNAG technique had a positive effect on pain severity, flexibility, trunk muscle endurance, and muscle stiffness in patients with nonspecific LBP.


Asunto(s)
Dolor de la Región Lumbar , Método Doble Ciego , Femenino , Humanos , Dolor de la Región Lumbar/diagnóstico por imagen , Dolor de la Región Lumbar/terapia , Región Lumbosacra , Masculino , Músculos , Músculos Paraespinales/diagnóstico por imagen , Estudios Prospectivos , Adulto Joven
8.
Clin Otolaryngol ; 45(2): 231-238, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31854074

RESUMEN

OBJECTIVE: To determine audiological outcomes of children who use a cochlear implant (CI) in one ear and an auditory brainstem implant (ABI) in the contralateral ear. DESIGN: Retrospective case review. SETTING: Tertiary referral hospital. PARTICIPANTS: Twelve children followed with CI and contralateral auditory brainstem implant (ABI) by Hacettepe University Department of Otorhinolaryngology and Audiology in Turkey. All children were diagnosed with different inner ear malformations with cochlear nerve aplasia/hypoplasia. CI was planned in the ear with better sound detection during behavioural testing with inserted ear phones and with better CN as seen on MRI. Due to the limited auditory and speech progress with the cochlear implant, ABI was performed on the contralateral ear in all subjects. MAIN OUTCOME MEASURES: Audiological performance and auditory perception skills of children with cochlear nerve deficiency (CND) who use bimodal electrical stimulation with CI and contralateral ABI. RESULTS: Mean age of the subjects was 84.00 ± 33.94 months. Age at CI surgery and ABI surgery was 25.00 ± 10.98 months and 41.50 ± 16.14 months, respectively. However, hearing thresholds only with CI and only with ABI did not reveal significant difference, and auditory perception scores improved with bimodal stimulation. The MAIS scores were significantly improved from unilateral CI to bimodal stimulation (P = .002). Pattern perception and word recognition scores were significantly higher with the bimodal condition when compared to CI only and ABI only conditions. CONCLUSION: Children with CND showed better performance with CI and contralateral ABI combined. Depending on the audiological and radiological results, bimodal stimulation should be advised for children with CND.


Asunto(s)
Implantes Auditivos de Tronco Encefálico , Percepción Auditiva/fisiología , Implantes Cocleares , Nervio Coclear/anomalías , Oído Interno/anomalías , Pérdida Auditiva Sensorineural/cirugía , Percepción del Habla/fisiología , Preescolar , Nervio Coclear/cirugía , Oído Interno/cirugía , Femenino , Estudios de Seguimiento , Pérdida Auditiva Sensorineural/fisiopatología , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
9.
Audiol Neurootol ; 24(3): 147-153, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31307043

RESUMEN

BACKGROUND: Cochlear nerve deficiency is a general term used to describe both cochlear nerve hypoplasia (CNH) and cochlear nerve aplasia. Although these two conditions can have similar results on audiological evaluation, CNH yields more variation in audiological tests. OBJECTIVES: To describe the audiological characteristics of the CNH cases in our series in relation to radiological findings. METHODS: We reviewed the medical charts, audiological findings, and radiological findings on cases with CNH. We included cases with CNH in one ear or both ears. Out of 90 subjects with CNH, we included a total of 40 individuals (21 women and 19 men; 49 ears) in the current study. We reviewed and analyzed the participants' audiological test results according to the radiological findings. RESULTS: Cases with CNH showed variations according to the cochlear structure. There were 13 normal cochleae, 4 with incomplete partition type I, and 32 with cochlear hypoplasia. The accompanying cochlear apertures also showed variation: 17 were normal, 28 stenotic, and 4 aplastic cochlear apertures. The subjects displayed hearing loss ranging from moderate to profound; furthermore, 4 subjects had no response to sound whatsoever. The degree of hearing loss was not statistically significantly different with regard to the presence or absence of cochlear malformation with CNH (p > 0.005). We observed both sensorineural hearing loss and mixed-type hearing loss among the CNH cases. CONCLUSIONS: CNH is the presence of a cochlear nerve that is smaller in diameter than the facial nerve. It can be accompanied with other associated inner ear malformations of different degrees of severity. We observed degrees of hearing loss ranging from moderate to profound.


Asunto(s)
Nervio Coclear/anomalías , Perdida Auditiva Conductiva-Sensorineural Mixta/fisiopatología , Pérdida Auditiva Sensorineural/fisiopatología , Adolescente , Audiometría , Niño , Preescolar , Nervio Coclear/fisiopatología , Femenino , Humanos , Lactante , Masculino , Adulto Joven
10.
Audiol Neurootol ; 24(6): 279-284, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31665723

RESUMEN

BACKGROUND: Cochlear implantation (CI) is an effective treatment option for patients with severe-to-profound hearing loss. When CI first started, it was recommended to wait until at least 4 weeks after the CI surgery for the initial activation because of possible complications. Advances in the surgical techniques and experiences in fitting have made initial activation possible within 24 h. OBJECTIVES: To compare the complaints and complications after early activation between behind-the-ear (BTE) and off-the-ear (OTE) sound processors and to show the impact of early activation on the electrode impedance values. METHOD: CI surgeries performed between March 2013 and July 2018 were retrospectively analyzed from the database. In total, 294 CI users were included in the present study. The impedance measurements were analyzed postoperatively at the initial activation prior to the stimulation, and 4 weeks after the initial activation in the first-month follow-up visit. A customized questionnaire was administered in the first-month follow-up fitting session to caregivers and/or patients who were using CI at least for 6 months. Medical records were also reviewed to identify any postoperative complications. RESULTS: In the early activation group, impedance values were significantly lower than in the control group (p < 0.05) at first fitting. At the first-month follow-up, no significant difference was found between the groups (p > 0.05). The most common side effects were reported to be edema (6.1%) and pain (5.7%) in the early activation group. In patients with OTE sound processors, the rate of side effects such as skin infection, wound swelling, skin hyperemia, and pain was higher than in patients with BTE sound processors; however, a statistical significance was only observed in wound swelling (p = 0.005). Selecting the appropriate magnet was defined as a problem for the OTE sound processors during the initial activation. CONCLUSION: This study revealed that early activation of CI was clinically safe and feasible in patients with BTE sound processors. When using OTE sound processors, the audiologists should be careful during the activation period and inform patients of possible side effects. The first fitting should be delayed for 4 weeks after CI for OTE sound processors. This current study is the first to report this finding with 5 years of experience in a large cohort.


Asunto(s)
Implantación Coclear/métodos , Implantes Cocleares , Sordera/rehabilitación , Ajuste de Prótesis/métodos , Adolescente , Adulto , Anciano , Niño , Preescolar , Edema/epidemiología , Femenino , Humanos , Hiperemia/epidemiología , Lactante , Masculino , Persona de Mediana Edad , Ruido , Dolor Postoperatorio/epidemiología , Complicaciones Posoperatorias , Estudios Retrospectivos , Procesamiento de Señales Asistido por Computador , Percepción del Habla , Infección de la Herida Quirúrgica , Encuestas y Cuestionarios , Adulto Joven
11.
Pediatr Cardiol ; 39(8): 1547-1553, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29980825

RESUMEN

We evaluated the natural course of congenital aortic valvular stenosis (AVS) and factors affecting AVS progression during long-term follow-up with echocardiography. Medical records of 388 patients with AVS were reviewed; patients with concomitant lesions other than aortic regurgitation (AR) were excluded. Trivial AVS was defined as a transvalvular Doppler peak systolic instantaneous gradient of < 25 mmHg; mild stenosis, 25-49 mmHg; moderate stenosis, 50-75 mmHg; and severe stenosis, > 75 mmHg. Median age of the patients was 3 years (range 0 day to 21 years), and 287 (74%) were male. A total of 355 patients were followed with medical treatment alone for a median of 4.6 years (range 1 month to 20.6 years), and the degree of AVS increased in 75 (21%) patients. The risk of AVS progression was higher when AVS was diagnosed in neonates (OR 4.29, CI 1.81-10.18, p = 0.001) and infants (OR 3.79, CI 2.21-6.49, p = 0.001). After the infancy period, bicuspid valve morphology increased AVS progression risk (OR 2.4, CI 1.2-4.6, p = 0.034). Patients with moderate AVS were more likely to have AVS progression (OR 2.59, CI 1.3-5.1, p = 0.006). Bicuspid valve morphology increased risk of AR development/progression (OR 1.77, CI 1.1-2.7, p = 0.017). The patients with mild and moderate AVS were more likely to have AR development/progression (p = 0.001). The risk of AR development/progression was higher in patients with AVS progression (OR 2.25, CI 1.33-3.81, p = 0.002). Newborn babies and infants should be followed more frequently than older patients according to disease severity. Bicuspid aortic valve morphology and moderate stenosis are risk factors for the progression of AVS and AR.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Doppler en Color , Adolescente , Adulto , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/congénito , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Niño , Preescolar , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/patología , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Adulto Joven
12.
Pediatr Cardiol ; 39(8): 1554-1560, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29923134

RESUMEN

The two main modalities used for congenital aortic valvular stenosis (AVS) treatment are balloon aortic valve dilatation (BAD) and surgical aortic valvuloplasty (SAV). This study evaluates residual and recurrent stenosis, aortic regurgitation (AR) development/progression, reintervention rates, and the risk factors associated with this end point in patients with non-critical congenital AVS who underwent BAD or SAV after up to 18 years of follow-up. From 1990 to 2017, 70 consecutive interventions were performed in patients with AVS, and 61 were included in this study (33 BADs and 28 SAVs). There were no significant differences in age, sex distribution, PSIG, and AR frequency between the BAD and SAV groups. Bicuspid valve morphology was more common in the BAD group than the SAV group. There was no statistically significant difference between PSIGs and AR development or progression after intervention at the immediate postoperative echocardiography of patients who underwent BAD or SAV (p = 0.82 vs. p = 0.29). Patients were followed 6.9 ± 5.1 years after intervention. The follow-up period in the SAV group was longer than that of the BAD group (9.5 ± 5.4 vs. 5.5 ± 4.4 years, p = 0.003). There was no statistically significant difference in the last echocardiographic PSIG between patients who underwent SAV or BAD (51.1 ± 33.5 vs. 57.3 ± 35.1, p = 0.659). Freedom from reintervention was 81.3% at 5 years and 57.5% at 10 years in the BAD group and 95.5% at 5 years and 81.8% at 10 years in the SAV group, respectively (p = 0.044). There was no difference in postprocedural immediate PSIG and last PSIG at follow-up and the development/progression of AR between patients who were treated with BAD versus SAV. However, long-term results of SAV were superior to those of BAD, with a somewhat prolonged reintervention interval.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón/métodos , Adolescente , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/etiología , Valvuloplastia con Balón/efectos adversos , Niño , Preescolar , Progresión de la Enfermedad , Ecocardiografía/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Recurrencia , Reoperación/estadística & datos numéricos , Factores de Riesgo , Tasa de Supervivencia , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Resultado del Tratamiento
13.
Eur Arch Otorhinolaryngol ; 274(9): 3315-3326, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28631161

RESUMEN

The objective of the study was to discuss the findings of intraoperative electrically evoked auditory brainstem response (eABR) test results with a recently designed intracochlear test electrode (ITE) in terms of their relation to decisions of cochlear or auditory brainstem implantation. This clinical study was conducted in Hacettepe University, Department of Otolaryngology, Head and Neck Surgery and Department of Audiology. Subjects were selected from inner ear malformation (IEM) database. Eleven subjects with profound sensorineural hearing loss were included in the current study with age range from 1 year 3 months to 4 years 3 months for children with prelingual hearing loss. There was only one 42-year-old post-lingual subject. eABR was recorded with an ITE and intraoperatively with an original cochlear implant (CI) electrode in 11 cases with different IEMs. Findings of eABR with ITE and their relation to the decision for CI or auditory brainstem implant (ABI) are discussed. Positive eABR test results were found to be dependent on close to normal cochlear structures and auditory nerve. The probability of positive result decreases with increasing degree of malformation severity. The prediction value of eABR via ITE on decision for hearing restoration was found to be questionable in this study. The results of eABR with ITE have predictive value on what we will get with the actual CI electrode. ITE appears to stimulate the cochlea like an actual CI. If the eABR is positive, the results are reliable. However, if eABR is negative, the results should be evaluated with preoperative audiological testing and MRI findings.


Asunto(s)
Implantación Auditiva en el Tronco Encefálico , Implantes Auditivos de Tronco Encefálico , Implantación Coclear , Implantes Cocleares , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Pérdida Auditiva Sensorineural/terapia , Adulto , Preescolar , Toma de Decisiones Clínicas , Estudios de Cohortes , Femenino , Humanos , Lactante , Masculino
15.
Ann Otol Rhinol Laryngol ; 123(8): 529-36, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24634154

RESUMEN

OBJECTIVE: The objective was to provide information about methods used and preliminary outcomes for pediatric ABI (auditory brainstem implant). STUDY DESIGN: An analysis of outcome was performed in children who received an ABI. METHODS: Twelve children received a MED-EL ABI system. Progress in audition and language was monitored through parental reports, questionnaires, profiles, and closed-set tests. RESULTS: The median number of active electrodes was 9 of 12. Seven of 12 users consistently respond to sound, and 5 of 12 do not. Highest performers can recognize words in small sets and have begun to use some words. CONCLUSION: Auditory brainstem implants appear to be beneficial for some pediatric patients who cannot benefit from traditional cochlear implant surgery. Benefits in the short-term can be recognition of environmental sounds, recognition of some words and very commonly used phrases, and the beginning use of words. Although some of our ABI users demonstrate no response to sound, they do want to wear their sound processors all waking hours. The cause of lack of response may be related to the second intervention, which might have led to displacement of the electrode array, or presence of additional handicaps or syndromes. However, the results are less than optimal. The relatively short postoperative follow-up duration is a considered weakness of this study.


Asunto(s)
Implantación Auditiva en el Tronco Encefálico/métodos , Implantes Auditivos de Tronco Encefálico , Sordera/cirugía , Inteligibilidad del Habla , Umbral Auditivo , Preescolar , Potenciales Evocados Auditivos del Tronco Encefálico , Femenino , Humanos , Ajuste de Prótesis , Sonido
16.
Ann Otol Rhinol Laryngol ; 133(3): 330-336, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38130098

RESUMEN

OBJECTIVES: Spatial cognition is a perceptual-motor function that pertains to the comprehension and processing of two-dimensional and three-dimensional space. The impairment of any sensory system can have adverse effects on cognitive functioning. The objective of this study is to examine spatial cognition in adults with hearing impairments. METHODS: There were a total of 61 individuals in this study: thirty-six with hearing loss and 25 with normal hearing. The Spatial Orientation Test (SOT), the Mental Rotation test (MR), and the Money's Road Map Test (RMT) were administered to assess participants' spatial learning-orientation, mental imagery-rotation, and spatial navigation abilities. A high number of errors in RMT, high angle difference in SOT and a low score in MR suggest poor spatial abilities. RESULTS: Participants with hearing loss had a greater number of RMT errors and SOT angle difference, but lower MR scores than those with normal hearing (P < .001). Hearing impairment negatively impacted all 3 spatial cognitive assessments. Hearing loss was associated with a 6.9 increase in the number of RMT errors (95% Confidence Interval (CI): 4.8, 9), a 23.6 increase in the SOT angle difference (95% CI: 16, 31.2), and an 8.5 decrease in the MR score (95% CI: -10.8, -6.2). CONCLUSIONS: The study found that individuals with hearing loss exhibited lower performance in various cognitive tasks related to spatial orientation, navigation, spatial learning, mental imagery, and rotation abilities when compared to an age and sex matched control group. In future study, it is imperative to place greater emphasis on hearing loss as a potential detrimental factor in the prediction of spatial cognition impairment.


Asunto(s)
Pérdida Auditiva , Orientación Espacial , Adulto , Humanos , Cognición , Percepción Espacial , Pérdida Auditiva/diagnóstico
17.
Cochlear Implants Int ; : 1-10, 2024 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-39319426

RESUMEN

OBJECTIVES: The aim was to construct validity and reliability of the Hearing Implant Sound Quality Index Questionnaire (HISQUI19) in Turkish. METHODS: This study was a methodologic study to validate HISQUI19 in Turkish. The study included 62 cochlear implant users. Guttman's split half-coefficient and Cronbach's alpha tests were used for construct validity and internal consistency. Pearson correlation test was used to assess the relationship of the HISQUI19 total score to the SSQ49 scales for CI users and to show test - retest reliability. RESULTS: The Cronbach's α value was 0.94 overall score with high internal consistency (Guttman's split-half-coefficient: 0.912). Test-retest reliability results showed high repeatability and consistency of the measure across time (r = 0.708; P = 0.002). Support for conducting factor analysis was provided by the KMO test, with a value of 0.876, which is 'great'. DISCUSSION: Subjective evaluation of cochlear implant users' daily life experiences is a useful tool to reveal the auditory benefits of cochlear implant usage. CONCLUSION: Turkish version of the HISQUI19 is a reliable and valid assessment tool for adults with CIs. This questionnaire provides clinicians with a valuable, reliable, and valid tool for determining the subjective benefit of CI for patients.

18.
Am J Audiol ; 31(1): 155-165, 2022 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-35114797

RESUMEN

PURPOSE: This study aimed to investigate the validity and reliability of the Turkish version of the Auditory Behavior in Everyday Life (ABEL) questionnaire. METHOD: The ABEL questionnaire was translated into Turkish using the "back-translation" method. The study included 130 parents of children with cochlear implantation, and 126 parents of children with typical hearing were included as a control group. In the study group, there were 62 unilateral and 68 bilateral cochlear implant (CI) users. The age at implantation ranged from 1 to 10 years, as they have substantial auditory skills. The participants' parents completed the ABEL individually, and 73 parents (28, study group; 45, control group) completed the ABEL again for test-retest reliability. Construct validity was tested using confirmatory factor analysis (CFA), and internal consistency was tested using Cronbach's alpha. Spearman's correlation test was used to assess the external validity of the total and all subscales of the ABEL and the Meaningful Auditory Integration Scale (MAIS). Test-retest reliability was measured using the intraclass correlation coefficient. RESULTS: The Cronbach's α values for subscales ranged from .67 to .89, and the value was .93 (excellent) for the overall scale. External validity analyses showed moderate to strong correlations between the total and subscale scores of the ABEL and the MAIS, indicating high external validity. According to the CFA findings, the construct validity of the Turkish version of the ABEL was satisfactory. For the three-factor structure, the goodness-of-fit indices revealed a good fit, and only the normed fit index revealed an acceptable fit. CONCLUSION: The Turkish version of the ABEL is a reliable and valid assessment tool for children with CIs.


Asunto(s)
Implantes Cocleares , Traducciones , Niño , Preescolar , Análisis Factorial , Humanos , Lactante , Reproducibilidad de los Resultados , Encuestas y Cuestionarios
19.
Int J Pediatr Otorhinolaryngol ; 155: 111084, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35217268

RESUMEN

OBJECTIVES: The aim was to evaluate the cochlear implant (CI) mapping parameters of CI users with inner ear malformation (IEM) and to reveal the changes in parameters over time. METHODS: In total, 118 CI users were included with 127 ears (68-IEM; 59-normal cochlear anatomy) in present retrospective study. The impedance measurements, thresholds levels-THR, most comfortable levels- MCL, pulse width-PW and rate values were analyzed in both IEM and control group at the initial activation, 6th,12th and 24th months postoperatively. RESULTS: There were statistically significant differences in impedance measurements in several time points. And also, there was a remarkable difference in THR & MCL and PW values between IEM and control groups in all time points (p < 0.05). THR & MCL levels and PW values increased significantly between all time periods in both groups (p < 0,008) and values of parameters in IEM-group were higher than those of control group. When comparing rates, statistically significant difference was observed only at the initial activation in both within (p < 0.001) and between groups (p = 0.03). CONCLUSION: Pediatric CI users with IEM need individual changes in fitting parameters. More frequent map sessions should be planned as they require more PW, THR and MCL increase over time. The increase rate differs between IEM subgroups depending on the deviation of malformation from the normal cochlear anatomy. This study is the first to in its attempt to reveal the mapping characteristics and long-term changes in pediatric CI users with different IEM subgroups.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Niño , Cóclea/anomalías , Cóclea/cirugía , Humanos , Estudios Retrospectivos
20.
Otol Neurotol ; 43(1): e50-e55, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34699402

RESUMEN

OBJECTIVE: To report the audiological, rehabilitative, and surgical outcomes of revision surgery for pediatric auditory brainstem implant (ABI) users. STUDY DESIGN: Retrospective cohort. SETTING: Tertiary referral center. PATIENTS: Five pediatric ABI users who had revision surgery for device malfunctions. INTERVENTIONS: Revision surgery for ABI malfunctions. MAIN OUTCOME MEASURES: The findings of free-field audiometry with the device, the Meaningful Auditory Integration Scale, and the pattern discrimination, word identification, sentence recognition, and expressive and receptive language tests before the device failure and after revision surgery were obtained from the patient records and compared. RESULTS: The revision rate for pediatric ABI was 6.45%. The Meaningful Auditory Integration Scale and expressive-receptive language scores showed improvements following revision surgery, while the aided thresholds, pattern perception, and word identification scores did not change. Individual differences in performance for these measures were observed. CONCLUSION: Equal or improved performance after the revision surgeries in the current study showed that revision surgery is successful and important for pediatric ABI users. It is essential to consider remedying the loss of auditory input in sensitive periods of pediatric development.


Asunto(s)
Implantes Auditivos de Tronco Encefálico , Sordera , Percepción del Habla , Niño , Sordera/cirugía , Humanos , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA