Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Arthroplasty ; 30(10): 1705-9, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26024988

RESUMEN

Decreasing hospital length of stay may attenuate costs associated with total knee arthroplasty. The purpose of this study was to determine if updates to an existing orthopedic enhanced recovery after surgery (ERAS) pathway would improve length of hospitalization. Clinical and demographic data were collected on 252 primary total knee arthroplasties between January 2012 and July 2013. Pre-updated and post-updated ERAS pathway cohorts were analyzed for length of stay, clinical outcomes, and re-admissions. The mean length of stay decreased from 76.6 hours to 56.1 hours after implementation of the evidence-based orthopedic enhanced recovery after surgery pathway (P<0.001). This improvement was possible without a concomitant increase in readmission rates.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/rehabilitación , Vías Clínicas/estadística & datos numéricos , Tiempo de Internación/estadística & datos numéricos , Anciano , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Ortopedia/estadística & datos numéricos , Estudios Retrospectivos
2.
Arthritis Rheumatol ; 72(4): 598-608, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31702112

RESUMEN

OBJECTIVE: Synovial membrane inflammation is common in osteoarthritis (OA) and increases cartilage injury. However, synovial fluid and histology studies suggest that OA inflammatory responses are not homogeneous. Greater understanding of these responses may provide new insights into OA disease mechanisms. We undertook this study to develop a novel multiparameter approach to phenotype synovial responses in knee OA. METHODS: Cell composition and soluble protein production were measured by flow cytometry and multiplex enzyme-linked immunosorbent assay in synovium collected from OA patients undergoing knee replacement surgery (n = 35). RESULTS: Testing disaggregation conditions showed that aggressive digestion improved synovial cell yield and mesenchymal staining by flow cytometry, but it negatively impacted CD4+ T cell and CD56+ natural killer cell staining. Less aggressive digestion preserved these markers and showed highly variable T cell infiltration (range 0-43%; n = 32). Correlation analysis identified mesenchymal subpopulations associated with different nonmesenchymal populations, including macrophages and T cells (CD45+CD11b+HLA-DR+ myeloid cells with PDPN+CD73+CD90-CD34- mesenchymal cells [r = 0.65, P < 0.0001]; and CD45+CD3+ T cells with PDPN+CD73+CD90+CD34+ mesenchymal cells [r = 0.50, P = 0.003]). Interleukin-6 (IL-6) measured by flow cytometry strongly correlated with IL-6 released by ex vivo culture of synovial tissue (r = 0.59, P = 0.0012) and was highest in mesenchymal cells coexpressing CD90 and CD34. IL-6, IL-8, complement factor D, and IL-10 release correlated positively with tissue cellularity (P = 0.0042, P = 0.018, P = 0.0012, and P = 0.038, respectively). Additionally, increased CD8+ T cell numbers correlated with retinol binding protein 4 (P = 0.033). Finally, combining flow cytometry and multiplex data identified patient clusters with different types of inflammatory responses. CONCLUSION: We used a novel approach to analyze OA synovium, identifying patient-specific inflammatory clusters. Our findings indicate that phenotyping synovial inflammation may provide new insights into OA patient heterogeneity and biomarker development.


Asunto(s)
Linfocitos T CD4-Positivos/metabolismo , Células Asesinas Naturales/metabolismo , Osteoartritis de la Rodilla/metabolismo , Membrana Sinovial/metabolismo , Anciano , Artroplastia de Reemplazo de Rodilla , Biomarcadores/metabolismo , Linfocitos T CD4-Positivos/patología , Femenino , Citometría de Flujo , Humanos , Inflamación/metabolismo , Inflamación/patología , Interleucina-6/metabolismo , Células Asesinas Naturales/patología , Articulación de la Rodilla/metabolismo , Articulación de la Rodilla/patología , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/patología , Osteoartritis de la Rodilla/cirugía , Membrana Sinovial/patología
3.
J Bone Joint Surg Am ; 86(6): 1211-6, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15173294

RESUMEN

BACKGROUND: The suture configurations in arthroscopic rotator cuff repairs have been limited to simple and horizontal stitches. Recent objective evaluations have demonstrated high failure rates of arthroscopic repairs of rotator cuff tears. A novel stitch for arthroscopic repair of the rotator cuff, the massive cuff stitch, was developed to increase the strength of the suture-tendon interface. The goal of this study was to determine the biomechanical properties of the massive cuff stitch and to compare it with other stitches commonly used for rotator cuff repair. METHODS: Eight pairs of sheep infraspinatus tendons were harvested and split in half to yield a set of four tendon specimens from each animal. Four stitch configurations (simple, horizontal, massive cuff, and modified Mason-Allen) were randomized and biomechanically tested in each set of tendon specimens. Each specimen was first cyclically loaded on an MTS uniaxial load frame under force control from 5 to 30 N at 0.25 Hz for twenty cycles. Each specimen was then loaded to failure under displacement control at a rate of 1 mm/sec. Cyclic elongation, peak-to-peak displacement, ultimate tensile load, and stiffness were measured with use of an optical motion analysis system and load-cell output. The type of failure (suture breakage or pull-out) was also recorded. A repeated-measures analysis of variance was performed on the results, with the alpha level of significance set at p < 0.05. RESULTS: There was no difference in cyclic elongation or peak-to-peak displacement among the four stitches. Ultimate tensile load was significantly higher (p < 0.05) for the massive cuff stitch (233 +/- 40 N) and the modified Mason-Allen stitch (246 +/- 40 N) than it was for either the simple stitch (72 +/- 18 N) or the horizontal stitch (77 +/- 15 N). There was no significant difference in the ultimate load between the massive cuff and modified Mason-Allen stitches. There was also no difference in stiffness among the four stitches. The simple and horizontal stitches failed by tissue pull-out, whereas the massive cuff and Mason-Allen stitches failed by a mixture of suture breakage and pull-out. CONCLUSIONS: The massive cuff stitch provides strength comparable with that of the modified Mason-Allen stitch commonly used in open rotator cuff repair. The ultimate tensile load before failure of the massive cuff stitch was significantly higher (p < 0.05) than that of the simple and horizontal stitches.


Asunto(s)
Manguito de los Rotadores/cirugía , Técnicas de Sutura , Animales , Artroscopía , Lesiones del Manguito de los Rotadores , Ovinos , Estrés Mecánico , Traumatismos de los Tendones/cirugía , Resistencia a la Tracción , Factores de Tiempo
4.
J Biomech ; 43(11): 2203-7, 2010 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-20451913

RESUMEN

The purpose of this study was to examine how a natural knee responds to the inputs of a total knee replacement testing standard developed by the International Organization for Standardization (ISO). This load control standard prescribes forces to be used for wear testing of knee replacements independent of implant size or design. A parallel ISO standard provides wear testing inputs that are displacement based instead of force based. Eight fresh frozen cadaveric knees were potted and tested in a 6 degree of freedom knee simulator using the load-control standard. The resulting displacements during load-control testing were compared to the prescribed displacements of the ISO displacement standard. At half the tibial torque prescribed by the load standard there was three times more average internal tibial rotation (20.3 degrees) than is prescribed by the displacement standard (5.7 degrees). The AP motion resulting from load testing was much different than is specified by the displacement standard. All eight knees had anterior tibial translation with respect to the femur during swing phase while the displacement standard specifies posterior tibial displacement. The variation in these motions among knees and their difference from the ISO displacement standard may be one factor that explains why wear results of total knee replacements based on ISO load or displacement testing frequently do not agree with each other or with clinical retrievals.


Asunto(s)
Análisis de Falla de Equipo/instrumentación , Análisis de Falla de Equipo/normas , Articulación de la Rodilla/fisiopatología , Prótesis de la Rodilla , Adulto , Anciano , Femenino , Humanos , Internacionalidad , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Soporte de Peso
5.
Clin Orthop Relat Res ; 466(5): 1251-6, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18219545

RESUMEN

Parachordoma, or myoepithelioma, is a very rare tumor histologically resembling chordoma but occurring in the nonaxial soft tissues. It typically has an indolent nature, with occasional late recurrence and even rare metastases. Review of existing literature reveals a male predilection, with the tumor typically occurring in the fourth decade of life in the lower extremity. It typically is managed with wide resection. We report the case of a 60-year-old woman with a right distal upper arm parachordoma treated with wide resection of the tumor.


Asunto(s)
Mioepitelioma/patología , Neoplasias de los Tejidos Blandos/patología , Brazo , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Mioepitelioma/diagnóstico por imagen , Mioepitelioma/cirugía , Radiografía , Neoplasias de los Tejidos Blandos/diagnóstico por imagen , Neoplasias de los Tejidos Blandos/cirugía , Resultado del Tratamiento
6.
J Hand Surg Am ; 32(3): 356-66, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17336844

RESUMEN

PURPOSE: To compare the mechanical behavior of a novel internal tendon repair device with commonly used 2-strand and 4-strand repair techniques for zone II flexor tendon lacerations. METHODS: Thirty cadaveric flexor digitorum profundus tendons were randomized to 1 of 3 core sutures: (1) cruciate locked 4-strand technique, (2) modified Kessler 2-strand core suture technique, or (3) Teno Fix multifilament wire tendon repair device. Each repair was tested in the load control setting on a Instron controller coupled to an MTS materials testing machine load frame by using an incremental cyclic linear loading protocol. A differential variable reluctance transducer was used to record displacement across the repair site. Cyclic force (n-cycles) to 1-mm gap and repair failure was recorded using serial digital photography. RESULTS: There was no significant difference in differential variable reluctance transducer displacement between the cruciate, modified Kessler, and Teno Fix repairs. The cruciate repair had greater resistance to visual 1-mm repair-site gap formation and repair-site failure when compared with the Kessler and Teno Fix repairs. No significant difference was found between the modified Kessler repair and the Teno Fix repair. In all specimens, the epitenon suture failed before the core suture. Repair failure occurred by suture rupture in the 7 cruciate specimens that failed, with evidence of gap formation before failure. Seven of 10 modified Kessler repairs failed by suture rupture. All of the Teno Fix repairs failed by pullout of the metal anchor. CONCLUSIONS: The Teno Fix repair system did not confer a mechanical advantage over the locked cruciate or modified Kessler suture techniques for zone II lacerations in cadaveric flexor tendons during cyclic loading in a linear testing model. This information may help to define safe boundaries for postoperative rehabilitation when using this internal tendon repair device.


Asunto(s)
Laceraciones/cirugía , Traumatismos de los Tendones/cirugía , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Indicadores de Salud , Humanos , Masculino , Distribución Aleatoria , Estrés Mecánico , Técnicas de Sutura , Transductores
7.
J Arthroplasty ; 20(8): 1042-8, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16376261

RESUMEN

The pumping of fluid and polyethylene wear debris from the joint space to the retroacetabular bone is implicated in the pathogenesis of osteolysis. Three possible mechanisms for this pumping: pressure gradients, diaphragm pumping, and piston pumping were studied in vitro in a laboratory model. The simulated activities of rising from a chair and climbing stairs produced high-pressure gradients and high angles of loading that could pump fluid through the apical hole to the retroacetabular bone. A noncongruent liner acted as a diaphragm pump, producing pressures 6 times higher than that seen with a congruent liner. Pistoning motion of the liner produced pressures 8 times higher than when no pistoning occurs. These pumping mechanisms could be mitigated by the use of acetabular components without holes.


Asunto(s)
Articulación de la Cadera/fisiopatología , Prótesis de Cadera/efectos adversos , Osteólisis/etiología , Osteólisis/prevención & control , Acetábulo/cirugía , Fenómenos Biomecánicos , Articulación de la Cadera/cirugía , Humanos , Técnicas In Vitro , Polietileno/efectos adversos , Presión , Diseño de Prótesis , Propiedades de Superficie , Caminata/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA