1.
Minerva Cardioangiol ; 60(4): 415-23, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22858919

RESUMEN

AIM: Non-stent-based immediate release formulations of paclitaxel have been shown to reduce in-stent restenosis in animal experiments and clinical trials. In the porcine overstretch model paclitaxel dissolved in the contrast medium iopromide inhibited neointimal proliferation in a dose-dependent manner after intracoronary injection and was well tolerated. METHODS: As a first step entering clinical development, a phase I trial was performed using four ascending paclitaxel dose/concentration levels: samples of up to 100 mL of the contrast medium (iopromide) containing 10, 50, 100 or 200 µM paclitaxel or iopromide (controls) were randomly administered to patients assigned to bare metal stent implantation for single de novo coronary artery lesions. Safety variables, tolerability and angiographic parameters were assessed. RESULTS: Adverse events, ECG, systolic and diastolic blood pressure, left ventricular ejection fraction, leukocyte count, other hematological or clinical chemistry data did not reveal any trend which could be related to the study medication. Short-lasting serum paclitaxel concentrations remained significantly below those known from cancer therapy. Angiographic late lumen loss was 0.72±0.50 mm (N.=7) in controls versus 0.45±0.65 mm (N.=17) in all paclitaxel-treated patients; binary restenosis rate was 5/7(63%) versus 6/17 (35%) and target lesion revascularization rate was 4/8 (50%) versus 4/24 (17%). CONCLUSION: Intracoronary infusion of paclitaxel dissolved in an X-ray contrast medium was well tolerated. The results show restenosis inhibition, but the number of patients examined was too small to demonstrate a statistically significant inhibition.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Medios de Contraste/administración & dosificación , Reestenosis Coronaria/tratamiento farmacológico , Yohexol/análogos & derivados , Paclitaxel/administración & dosificación , Stents , Anciano , Algoritmos , Cateterismo Cardíaco/métodos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/terapia , Método Doble Ciego , Femenino , Alemania , Humanos , Inyecciones Intraarteriales , Yohexol/administración & dosificación , Masculino , Persona de Mediana Edad , Proyectos Piloto , Recurrencia , Stents/efectos adversos , Resultado del Tratamiento
2.
Minerva Cardioangiol ; 58(6): 677-90, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21135808

RESUMEN

This article addresses current pacing practices and issues. Pacing, sensing, sensing amplifiers, and pacing leads are discussed. Cardiac resynchronization is reviewed. Issues of ventricular pacing avoidance, pacemaker lead infections, ionizing radiation effects on pacing and pacing issues after deterioration and expiration of the patient are considered.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Marcapaso Artificial , Bradicardia/fisiopatología , Bradicardia/terapia , Estimulación Cardíaca Artificial/efectos adversos , Terapia de Resincronización Cardíaca , Electrocardiografía , Electrodos Implantados , Diseño de Equipo , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Marcapaso Artificial/efectos adversos , Calidad de Vida , Resultado del Tratamiento , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia
3.
Minerva Cardioangiol ; 58(5): 567-82, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20948503

RESUMEN

Restenosis following interventions in the coronary or peripheral arteries develops over weeks to months. In coronary arteries the restenosis rate has been markedly reduced since the advent of drug-eluting stents. Non-stent-based methods for local drug delivery enable restenosis inhibition without the need for stent implantation, does not permanently change the structure of the vessel, are repeatable, and seems to be applicable where drug-eluting stents provide insufficient protection. Preclinical data indicate that short exposure of the vessel wall to a lipophilic inhibitor of cell proliferation is sufficient for preventing restenosis. Initial evidence to this effect emerged from an investigation of paclitaxel embedded in a matrix that enhances the solubility and release of the agent from the balloon coating as well as its transfer to the vessel wall. Further corroborating data from preclinical and clinical studies demonstrating a reduction in late lumen loss and lower restenosis rates led to the market introduction of a variety of paclitaxel-coated angioplasty balloons. The effectiveness of restenosis inhibition is not determined by the active agent alone. Other factors that are crucial for the effectiveness and safety of drug-coated angioplasty balloons are the formulation containing the agent and the coating technique. In this review we first outline the development of paclitaxel-coated balloons to then provide an overview of the preclinical results obtained with different paclitaxel-coated balloons and finally compare these with the outcome in patients. The article concludes with a short outlook on initial results with a zotarolimus-coated angioplasty balloon.


Asunto(s)
Angioplastia Coronaria con Balón , Reestenosis Coronaria/prevención & control , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Paclitaxel/uso terapéutico , Sistemas de Liberación de Medicamentos , Humanos , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Sirolimus/uso terapéutico
4.
Minerva Cardioangiol ; 58(5): 583-8, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20948504

RESUMEN

Randomized clinical trials investigating the treatment of coronary in-stent restenosis with paclitaxel iopromide coated balloon catheters have shown favorable results. The aim of the present clinical investigation was to assess the efficacy of a novel paclitaxel urea coated angioplasty balloon in the treatment of coronary in-stent restenosis. A total of 26 restenotic bare metal stents in 23 patients with a lesion length of 22.8 ± 11.1 mm and a reference vessel diameter of 2.64 ± 0.31 mm were treated. Up to six months and including the six-month angiographic control, only one target lesion revascularization was necessary; in total, the rate of major adverse cardiovascular events until six-month follow-up was 4.3 %. In-stent late lumen loss was 0.07 ± 0.37 mm, in-segment late lumen loss 0.02 ± 0.50 mm. Binary restenosis was present in one patient (4.3%). The results of this first-in-human series with a paclitaxel urea coated balloon are comparable to paclitaxel iopromide coated balloon catheters. Randomized, controlled clinical trials are warranted to further evaluate this promising approach.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Reestenosis Coronaria/tratamiento farmacológico , Paclitaxel/administración & dosificación , Paclitaxel/uso terapéutico , Anciano , Catéteres , Angiografía Coronaria , Stents Liberadores de Fármacos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Stents , Urea/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA