RESUMEN
COVID-19 is heterogeneous; therefore, it is crucial to identify early biomarkers for adverse outcomes. Extracellular vesicles (EV) are involved in the pathophysiology of COVID-19 and have both negative and positive effects. The objective of this study was to identify the potential role of EV in the prognostic stratification of COVID-19 patients. A total of 146 patients with severe or critical COVID-19 were enrolled. Demographic and comorbidity characteristics were collected, together with routine haematology, blood chemistry and lymphocyte subpopulation data. Flow cytometric characterization of the dimensional and antigenic properties of COVID-19 patients' plasma EVs was conducted. Elastic net logistic regression with cross-validation was employed to identify the best model for classifying critically ill patients. Features of smaller EVs (i.e. the fraction of EVs smaller than 200 nm expressing either cluster of differentiation [CD] 31, CD 140b or CD 42b), albuminemia and the percentage of monocytes expressing human leukocyte antigen DR (HLA-DR) were associated with a better outcome. Conversely, the proportion of larger EVs expressing N-cadherin, CD 34, CD 56, CD31 or CD 45, interleukin 6, red cell width distribution (RDW), N-terminal pro-brain natriuretic peptide (NT-proBNP), age, procalcitonin, Charlson Comorbidity Index and pro-adrenomedullin were associated with disease severity. Therefore, the simultaneous assessment of EV dimensions and their antigenic properties complements laboratory workup and helps in patient stratification.
Asunto(s)
COVID-19 , Vesículas Extracelulares , Humanos , Biomarcadores , Monocitos , Interleucina-6RESUMEN
Thyroid dysfunctions are among the most common endocrine disorders and accurate biochemical testing is needed to confirm or rule out a diagnosis. Notably, true hyperthyroidism and hypothyroidism in the setting of a normal thyroid-stimulating hormone level are highly unlikely, making the assessment of free thyroxine (FT4) inappropriate in most new cases. However, FT4 measurement is integral in both the diagnosis and management of relevant central dysfunctions (central hypothyroidism and central hyperthyroidism) as well as for monitoring therapy in hyperthyroid patients treated with anti-thyroid drugs or radioiodine. In such settings, accurate FT4 quantification is required. Global standardization will improve the comparability of the results across laboratories and allow the development of common clinical decision limits in evidence-based guidelines. The International Federation of Clinical Chemistry and Laboratory Medicine Committee for Standardization of Thyroid Function Tests has undertaken FT4 immunoassay method comparison and recalibration studies and developed a reference measurement procedure that is currently being validated. However, technical and implementation challenges, including the establishment of different clinical decision limits for distinct patient groups, still remain. Accordingly, different assays and reference values cannot be interchanged. Two-way communication between the laboratory and clinical specialists is pivotal to properly select a reliable FT4 assay, establish reference intervals, investigate discordant results, and monitor the analytical and clinical performance of the method over time.
Asunto(s)
Hipertiroidismo , Hipotiroidismo , Humanos , Pruebas de Función de la Tiroides , Tiroxina , Radioisótopos de Yodo , Hipotiroidismo/diagnóstico , Hipertiroidismo/diagnóstico , Estándares de Referencia , Valores de ReferenciaRESUMEN
BACKGROUND & AIMS: A strategy to improve the low rate of anti-SARS-CoV-2 mRNA vaccine-induced immunogenicity in liver transplant recipients (LTs) is urgently needed. METHODS: We analysed the rate of positive (≥0.8 U/ml) anti-SARS-CoV-2 receptor domain-binding protein (RBD) antibody response 2 months after a third dose of the BNT16b2 vaccine in 107 LTs who completed the second vaccine dose 7 months earlier. RESULTS: A positive anti-SARS-CoV-2-s-RBD antibody response after the third vaccine dose was detected in 98 (91.6%) LTs compared to 82 (76.6%) after the second vaccine dose (p = .003). The median of anti-SARS-CoV-2 RBD antibody titres increased from 22.9 U/ml 6 months after the second to 3500 U/ml 2 months after the third vaccine dose (p < .001). Fourteen (14.3%) responder patients presented antibody titres <100 U/ml, 57 (58.2%) between 100 and 9999 U/ml and 27 (27.6%) ≥10 000 U/ml. Seropositivity after the second dose was maintained after the third dose. Independent predictors of antibody response failure after the third vaccine dose were taking a higher daily dose of mycophenolate mofetil (MMF, p < .001) and had a lower (<60 ml/min/1.73 m2 ) estimated glomerular filtration rate (p = .007). Nine (9.1%) LTs experienced symptomatic SARS-CoV-2 infection after the third vaccine dose. Median antibody titres were not statistically different between infected and not infected LTs (1325 vs 3515 U/ml, p = .678). CONCLUSIONS: The third dose of the BNT16b2 vaccine increased the number of LTs who developed a positive anti-SARS-CoV-2 s-RBD antibody response. A proportion of patients remained unresponsive, mainly for modifiable factors, such as the use of MMF or multiple immunosuppressants.
Asunto(s)
COVID-19 , Trasplante de Hígado , Humanos , COVID-19/prevención & control , SARS-CoV-2 , Anticuerpos Antivirales , Inmunosupresores , Ácido Micofenólico , Receptores de TrasplantesRESUMEN
Over the past three decades, laboratory medicine has significantly evolved thanks to technological advances made possible by new materials and evidence. Clinicians' ongoing requests for powerful, rapid, and minimally invasive tests has led manufacturers to develop rapid, accurate, and sensitive tests that can increase diagnostic accuracy and improve follow-up, bringing laboratory medicine ever closer to personalized medicine. The aim of this study was to critically review the main problems of the current Tg and CT biomarkers for the diagnosis/monitoring of DTC and MTC, respectively, and to identify the advantages and challenges of using the new laboratory biomarkers in the clinical management of patients with differentiated and medullary thyroid cancer. Insufficient harmonization of Tg and CT assays and lack of interchangeability of laboratory results and cutoff values pose challenges for comparability and standardization of procedures and methods. New diagnostic and monitoring approaches such as PCT or the Tg doubling time have proven to be effective. Close collaboration between clinicians and laboratory specialists remains essential to translate the advantages and limitations of current assays into appropriate clinical interpretation criteria. Over the years, the journal Clinical Chemistry and Laboratory Medicine (CCLM) has taken many steps to develop advanced research and technology in the diagnosis and monitoring of tumor cancer and to help clinicians translate it into clinical practice.
Asunto(s)
Biomarcadores de Tumor , Neoplasias de la Tiroides , Humanos , Tiroglobulina , Autoanticuerpos , Neoplasias de la Tiroides/diagnósticoRESUMEN
BACKGROUND: There is limited information to compare the qualitative and semi-quantitative performance of rapid diagnostic tests (RDT) and serology for the assessment of antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Therefore, the objective of the study was (a) to compare the efficacy of SARS-CoV-2 antibody detection between RDT and laboratory serology, trying to identify appropriate semi-quantitative cut-offs for RDT in relation with quantitative serology values and to (b) evaluate diagnostic accuracy of RDT compared to the NAAT gold standard in an unselected adult population. METHODS: SARS-CoV-2 antibodies were simultaneously measured with lateral flow immunochromatographic assays (LFA), the Cellex qSARS-CoV-2 IgG/IgM Rapid Test (by capillary blood), the iFlash-SARS-CoV-2 IgG/IgM chemiluminescent immunoassay (CLIA) (by venous blood) and the nucleic acid amplification test (NAAT) in samples from in- and out-patients with confirmed, suspected and negative diagnosis of coronavirus disease 2019 (COVID-19) attending Udine Hospital (Italy) (March-May 2020). Interpretation of RDT was qualitative (positive/negative) and semi-quantitative based on a chromatographic intensity scale (negative, weak positive, positive). RESULTS: Overall, 720 paired antibody measures were performed on 858 patients. The qualitative and semiquantitative agreement analysis performed in the whole sample between LFA and CLIA provided a Kendall's tau of 0.578 (p < 0.001) and of 0.623 (p < 0.001), respectively, for IgM and IgG. In patients with a diagnosis of COVID-19, accordance between LFA and CLIA was maintained as a function of time from the onset of COVID-19 disease and the severity of disease both for qualitative and semi-quantitative assessments. RDT compared to the NAAT gold standard in 858 patients showed 78.5% sensitivity (95% CI 75.1%-81.7%) and 94.1% specificity (95% CI 90.4%-96.8%), with variable accordance depending on the timing from symptom onset. CONCLUSION: The RDT used in our study can be a non-invasive and reliable alternative to serological tests and facilitate both qualitative and a semi-quantitative antibody detection in COVID-19.
Asunto(s)
COVID-19 , SARS-CoV-2 , Adulto , Humanos , COVID-19/diagnóstico , Estudios Prospectivos , Inmunoglobulina M , Sensibilidad y Especificidad , Anticuerpos Antivirales , Inmunoglobulina G , Inmunoensayo/métodosRESUMEN
The persistence of long-term coronavirus-induced disease 2019 (COVID-19) sequelae demands better insights into its natural history. Therefore, it is crucial to discover the biomarkers of disease outcome to improve clinical practice. In this study, 160 COVID-19 patients were enrolled, of whom 80 had a "non-severe" and 80 had a "severe" outcome. Sera were analyzed by proximity extension assay (PEA) to assess 274 unique proteins associated with inflammation, cardiometabolic, and neurologic diseases. The main clinical and hematochemical data associated with disease outcome were grouped with serological data to form a dataset for the supervised machine learning techniques. We identified nine proteins (i.e., CD200R1, MCP1, MCP3, IL6, LTBP2, MATN3, TRANCE, α2-MRAP, and KIT) that contributed to the correct classification of COVID-19 disease severity when combined with relative neutrophil and lymphocyte counts. By analyzing PEA, clinical and hematochemical data with statistical methods that were able to handle many variables in the presence of a relatively small sample size, we identified nine potential serum biomarkers of a "severe" outcome. Most of these were confirmed by literature data. Importantly, we found three biomarkers associated with central nervous system pathologies and protective factors, which were downregulated in the most severe cases.
Asunto(s)
COVID-19 , Proteómica , Biomarcadores/sangre , COVID-19/diagnóstico , Humanos , Recuento de Linfocitos , Aprendizaje AutomáticoRESUMEN
The aim of this study was to assess the long-term dynamics and factors associated with the serological response against the severe acute respiratory syndrome coronavirus 2 after primary infection. A prospective longitudinal study was conducted with monthly serological follow-up during the first 4 months, and then at 6, 8, and 10 months after the disease onset of all recovered adult in- and outpatients with coronavirus disease 2019 (COVID-19) attending Udine Hospital (Italy) during the first wave (from March to May 2020). A total of 546 individuals were included (289 female, mean age 53.1 years), mostly with mild COVID-19 (370, 68.3%). Patients were followed for a median of 302 days (interquartile range, 186 to 311). The overall seroconversion rate within 2 months was 32% for IgM and 90% for IgG. Seroreversion was observed in 90% of patients for IgM at 4 months and in 47% for IgG at 10 months. Older age, number of symptoms at acute onset, and severity of acute COVID-19 were all independent predictors of long-term immunity both for IgM (ß, linear regression coefficient, 1.10, P = 0.001; ß 5.15 P = 0.014; ß 43.84 P = 0.021, respectively) and for IgG (ß 1.43 P < 0.001; ß 10.46 P < 0.001; ß 46.79 P < 0.001, respectively), whereas the initial IgG peak was associated only with IgG duration (ß 1.12, P < 0.001). IgM antibodies disappeared at 4 months, and IgG antibodies declined in about half of patients 10 months after acute COVID-19. These effects varied depending on the intensity of the initial antibody response, age, and burden of acute COVID-19.
Asunto(s)
COVID-19 , SARS-CoV-2 , Adulto , Anciano , Anticuerpos Antivirales , Formación de Anticuerpos , Enfermedad Crítica , Femenino , Humanos , Inmunoglobulina M , Estudios Longitudinales , Persona de Mediana Edad , Estudios ProspectivosRESUMEN
Hyperthyroidism is a clinical condition characterized by inappropriately high synthesis and secretion of thyroid hormones by the thyroid gland. It has multiple aetiologies, manifestations and potential therapies. Graves' disease is the most common form of hyperthyroidism, due to the production of autoantibodies against thyrotropin receptor, capable of over-stimulating thyroid function. A reliable diagnosis of hyperthyroidism can be established on clinical grounds, followed by the evaluation of serum thyroid function tests (thyrotropin first and then free thyroxine, adding the measurement of free triiodothyronine in selected specific situations). The recent guidelines of both the American and European Thyroid Associations have strongly recommended the measurement of thyrotropin receptor autoantibodies for the accurate diagnosis and management of Graves' disease. If autoantibody test is negative, a radioiodine uptake should be performed. Considering the most recent laboratory improvements, binding assays can be considered the best first solution for the measurement of thyrotropin receptor autoantibodies in diagnosis and management of overt cases of Graves' disease. In fact, they have a satisfactory clinical sensitivity and specificity (97.4% and 99.2%, respectively) being performed in clinical laboratories on automated platforms together with the other thyroid function tests. In this setting, the bioassays should be reserved for fine and complex diagnoses and for particular clinical conditions where it is essential to document the transition from stimulating to blocking activity or vice versa (e.g. pregnancy and post-partum, related thyroid eye disease, Hashimoto's thyroiditis with extrathyroidal manifestations, unusual cases after LT4 therapy for hypothyroidism or after antithyroid drug treatment for Graves' disease). Undoubtedly, technological advances will help improve laboratory diagnostics of hyperthyroidism. Nevertheless, despite future progress, the dialogue between clinicians and laboratory will continue to be crucial for an adequate knowledge and interpretation of the laboratory tests and, therefore, for an accurate diagnosis and correct management of the patient.
Asunto(s)
Antitiroideos/inmunología , Autoanticuerpos/inmunología , Hipertiroidismo/diagnóstico , Receptores de Tirotropina/inmunología , Animales , Antitiroideos/farmacología , Autoanticuerpos/farmacología , Técnicas Biosensibles , Línea Celular , Humanos , Hipertiroidismo/tratamiento farmacológico , Radioisótopos de Yodo/química , Unión Proteica , Sensibilidad y Especificidad , Glándula TiroidesRESUMEN
BACKGROUND: The total testosterone (T) cutoffs clinically adopted to define late-onset hypogonadism (LOH) do not consider the differences that exist between different analytical platforms, nor do they consider the body mass index (BMI) or age of the patient. We aimed at providing method, age and BMI-specific normal values for total T in European healthy men. METHODS: A total of 351 eugonadal healthy men were recruited, and total T was measured with four automated immunometric assays (IMAs): ARCHITECT i1000SR (Abbott), UniCel DxI800 (Beckman Coulter), Cobas e601 (Roche), IMMULITE 2000 (Siemens) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Reference ranges (RRs) were calculated for each method. RESULTS: Passing and Bablok regression analysis and Bland-Altman plot showed an acceptable agreement between Abbott and LC-MS/MS, but a poor one between LC-MS/MS and the other IMAs. Age-specific T concentrations in non-obese (BMI <29.9 kg/m2) men were greater than in all men. The total T normal range, in non-obese men aged 18-39 years, measured with LC-MS/MS was 9.038-41.310 nmol/L. RRs calculated with LC-MS/MS statistically differed from the ones calculated with all individual IMAs, except Abbott and among all IMAs. Statistically significant differences for both upper and lower reference limits between our RRs and the ones provided by the manufacturers were also noticed. CONCLUSIONS: We calculated normal ranges in a non-obese cohort of European men, aged 18-39 years, with four commercially available IMAs and LC-MS/MS and found statistically significant differences according to the analytical method used. Method-specific reference values can increase the accuracy of LOH diagnosis and should be standardly used.
Asunto(s)
Inmunoensayo/métodos , Testosterona/análisis , Adolescente , Adulto , Índice de Masa Corporal , Cromatografía Líquida de Alta Presión/normas , Voluntarios Sanos , Humanos , Inmunoensayo/normas , Masculino , Juego de Reactivos para Diagnóstico , Valores de Referencia , Espectrometría de Masas en Tándem/normas , Testosterona/normas , Adulto JovenRESUMEN
Different imaging tools, circulating endocrine markers, and fine-needle aspiration (FNA) cytology are of great importance in the diagnosis and follow-up of different thyroid and parathyroid diseases. Sometimes, however, they are conflicting or inconclusive: interestingly, measuring endocrine markers (i.e. thyroglobulin, calcitonin, parathyroid hormone) in fluids from FNA proved to be a very useful complementary diagnostic tool in such cases. The determination of endocrine markers in fluids other than serum/plasma has been developed in the last years. Although studies have reported overall satisfactory results, a good standardization of procedures has not yet been reached, and further efforts should be made in order to better define pre-analytical, analytical, and post-analytical aspects. Here we reviewed critically the literature on the measurement of FNA endocrine markers, focusing on laboratory issues, such as preparation of the sample, choice of solution, and technical features of determination of these markers. Indeed, information for use of FNA-Tg, FNA-CT, and FNA-PTH in clinical practice was also provided.
Asunto(s)
Biopsia con Aguja Fina , Calcitonina/análisis , Pruebas de Química Clínica/métodos , Hormona Paratiroidea/análisis , Tiroglobulina/análisis , HumanosRESUMEN
BACKGROUND: Thyroid stimulating hormone (TSH) receptor autoantibodies (TRAb) are pathogenetic and diagnostic hallmarks of Graves' disease (GD). Three varieties of TRAb have been described: stimulating (S-TRAb), blocking (B-TRAb), and apoptotic (A-TRAb) autoantibodies. Very recently, the first immunoassay method (Immulite TSI assay, Siemens Healthcare Diagnostics) declared to measure serum S-TRAb concentration, has been made available in an automated commercial platform. The aim of the study was to evaluate the ability of this new test to identify patients suffering from GD, in comparison with two current IMA methods for total TSH receptor autoantibodies (T-TRAb) measurement. METHODS: Sera of 383 subjects [72 patients with untreated GD, 55 patients with autoimmune thyroiditis (AIT), 36 patients with multinodular non-toxic goiter, 100 patients with other non-thyroid autoimmune diseases (NTAD) and 120 healthy subjects (HS)] were evaluated. RESULTS: The threshold obtained by receiver operating characteristic (ROC) analysis was 0.54 IU/L, very similar to that proposed by the manufacturer (0.55 IU/L). Thyroid-stimulating immunoglobulins (TSI) were positive in all GD patients and negative in all but three controls (clinical sensitivity and specificity of 100% and 98.7%, respectively). Passing and Bablok regression analysis and Bland-Altman plot showed an acceptable agreement between TSI Immulite assay and other two immunoassay methods (Cobas/Elecsys, Roche and TRAK RIA, BRAHMS Thermo Scientific). CONCLUSIONS: The diagnostic performance of fully automated Immulite TSI assay in GD patients is at least comparable to that of current TRAb immunoassays (IMAs) suggesting the possibility of including such assay in rapid and cost-saving diagnostic and monitoring algorithms. However, our results do not provide full evidence that this assay is specific for S-TRAb only, and future studies comparing Immulite TSI assay to stimulating activity are required.
Asunto(s)
Autoanticuerpos/sangre , Enfermedad de Graves/sangre , Inmunoensayo/normas , Receptores de Tirotropina/sangre , Automatización , Femenino , Enfermedad de Graves/diagnóstico , Humanos , MasculinoRESUMEN
BACKGROUND: The use of automated immunometric methods for the detection of anti-thyroid peroxidase antibodies (TPOAb), the main serological marker of autoimmune thyroid diseases (AITD), has expanded in recent years. However, it is not known whether these new automated platforms have improved the diagnostic performance of TPOAb assays. The aim of this study was to evaluate the potential improvement of the inter-method agreement of current automated third generation systems, 12 years after a previous study, which had assessed the analytical variability between semi-automated second generation methods of TPOAb detection. METHODS: Eight pools of sera from patients with chronic lymphocytic thyroiditis, exhibiting different TPOAb concentrations, were collected from routine laboratory diagnostics and distributed to seven companies throughout Italy. All automated third generation methods were calibrated against the Medical Research Council (MRC) reference preparation 66/387. RESULTS: The overall mean variability (CV) was 93.6% when results were expressed in part as arbitrary Units (U/mL) and in part as International Units (IU/mL). The conversion of all values in IU/mL resulted in a significant decrease of CV (49.8%). The CV expressed as COM (cut-off concentration multiples) was 64.0%. Agreement of qualitative results was 95.3% with a pronounced difference in the threshold values proposed by manufacturers (range 3.2-35.0 IU/mL). CONCLUSIONS: These findings confirm the improvement of harmonisation between different methods of automated third generation TPOAb assays. Nevertheless, further efforts should be made in the definition of the positive cut-off concentration to avoid misclassification of AITD patients as well as in a new international reference preparation and in the autoantigen purification modality.
Asunto(s)
Autoanticuerpos/sangre , Autoanticuerpos/inmunología , Enfermedad de Hashimoto/diagnóstico , Enfermedad de Hashimoto/inmunología , Inmunoensayo/métodos , Yoduro Peroxidasa/inmunología , Automatización , Enfermedad de Hashimoto/sangre , Enfermedad de Hashimoto/enzimología , HumanosRESUMEN
Thyroglobulin (Tg) is an iodinated glycoprotein, which is normally stored in the follicular colloid of the thyroid, being a substrate for thyroid hormone production. Since it is produced by well-differentiated thyroid cells, it is considered a reliable tumor marker for patients with differentiated thyroid carcinoma (DTC) during their follow-up after total thyroidectomy and radioiodine ablation. It is used to monitor residual disease and to detect recurrent disease. After total thyroid ablation, unstimulated highly sensitive Tg measurements are sufficiently accurate to avoid exogenous or endogenous thyrotropin (TSH) stimulation and provide accurate diagnostic and prognostic information in the great majority of DTC patients. Adopting sophisticated statistical analysis, i.e., decision tree models, the use of Tg before radioiodine theranostic administration was demonstrated to be useful in refining conventional, pathology-based risk stratification and providing personalized adjuvant or therapeutic radioiodine administrations. The follow-up of DTC patients aims to promptly identify patients with residual or recurrent disease following primary treatment. Our review paper covers the diagnostic, theranostic and prognostic value of thyroglobulin in DTC patients.
RESUMEN
BACKGROUND: Phospholipid-dependent coagulation tests for lupus anticoagulant (LA) are considered an important step for the diagnosis of anti-phospholipid syndrome; however, LA laboratory detection is difficult because of many variables. Five hospital laboratories, located in a North-Italy area and using the same method for LA testing, cooperated to standardise sample treatment and analytical procedure in order to define the upper values for LA negativity. METHODS: In total, 200 normal subjects (40 for each centre) were studied for six LA functional assays, using the same procedure, reagent lot and analyser type. The first tests done were LA screen and LA confirm assays, based on diluted Russell's Viper Venom Time, with low and high phospholipid content, respectively. The second tests performed were silica clotting time screen and confirm assays, based on activated partial thromboplastin time, with low and high phospholipid content, respectively. Finally, two mixing assays were executed for both screening assays, diluting patient sample with a pool prepared with plasma collected from the study population. RESULTS: Data analysis demonstrated a difference between centres for all assays when results were expressed in seconds; the difference disappeared when results are normalised with the local mean normal value of each centre and are expressed as a normalised ratio. The study population was normally distributed; so the value corresponding to 99th percentile was used as limit value for LA negativity. Values expressed as normalised ratio, for LA and silica clotting time screenings were 1.22 and 1.23, respectively. CONCLUSIONS: The study allowed us to define a uniform approach to LA testing and evaluation for laboratories employing the same methods.
Asunto(s)
Síndrome Antifosfolípido/sangre , Síndrome Antifosfolípido/diagnóstico , Pruebas de Coagulación Sanguínea/normas , Inhibidor de Coagulación del Lupus/sangre , Adolescente , Adulto , Anciano , Síndrome Antifosfolípido/inmunología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Valores de Referencia , Adulto JovenAsunto(s)
Bacteriemia/diagnóstico , Cultivo de Sangre/estadística & datos numéricos , Proteína C-Reactiva/análisis , Polipéptido alfa Relacionado con Calcitonina/análisis , Anciano , Área Bajo la Curva , Bacteriemia/sangre , Bacteriemia/fisiopatología , Biomarcadores/análisis , Biomarcadores/sangre , Cultivo de Sangre/métodos , Estudios de Casos y Controles , Estudios de Cohortes , Femenino , Humanos , Italia , Modelos Logísticos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Polipéptido alfa Relacionado con Calcitonina/sangre , Curva ROC , Estudios RetrospectivosRESUMEN
OBJECTIVE: Thyroglobulin measurement is the cornerstone of modern management of differentiated thyroid cancer, with clinical decisions on treatment and follow-up based on the results of such measurements. However, numerous factors need to be considered regarding measurement with and interpretation of thyroglobulin assay results. DESIGN: The present document provides an integrated update to the 2013 and 2014 separate clinical position papers of our group on these issues. METHODS: Issues concerning analytical and clinical aspects of highly-sensitive thyroglobulin measurement will be reviewed and discussed based on an extensive analysis of the available literature. RESULTS: Thyroglobulin measurement remains a highly complex process with many pitfalls and major sources of interference, especially anti-thyroglobulin antibodies, need to be assessed, considered and, when necessary, dealt with appropriately. CONCLUSIONS: Our expert consensus group formulated 53 practical, graded recommendations for guidance on highly-sensitive thyroglobulin and TgAb in laboratory and clinical practice, especially valuable where current guidelines do not offer sufficient guidance.
Asunto(s)
Adenocarcinoma , Neoplasias de la Tiroides , Humanos , Consenso , Neoplasias de la Tiroides/diagnóstico , AutoanticuerposRESUMEN
PURPOSE: According to the American College of Medical Genetics (ACMG) classification, variants of uncertain significance (VUS) are gene variations whose impact on the disease risk is not yet known. VUS, therefore, represent an unmet need for genetic counselling. Aim of the study is the use the AlphaFold artificial intelligence algorithm to predict the impact of novel mutations of the IGFALS gene, detected in a subject with short stature and initially classified as VUS according to the ACMG classification. METHODS: A short-stature girl and her parents have been investigated. IGFALS mutations have been detected through clinical exome and confirmed by Sanger sequencing. The potential presence of co-occurring gene alterations was investigated in the proband by whole exome and CGH array. Structure of the ALS protein (encoded by the IGFALS gene) was evaluated through the AlphaFold artificial intelligence algorithm. RESULTS: Two IGFALS variants were found in the proband: c.1349T > C (p.Leu450Pro) and c.1363_1365delCTC (p.Leu455del), both classified as VUS, according to ACMG. Parents' analysis highlighted the in trans position of the two variants. AlphaFold showed that the mutated positions were found the concave side a horseshoe structure of the ALS protein, likely interfering with protein-protein interactions. According to a loss of function (LoF) effect of the two variants, reduced levels of the IGF1 and IGFBP-3 proteins, as well as a growth hormone (GH) excess were detected in the proband's serum. CONCLUSIONS: By using the AlphaFold structure we were able to predict two IGFALS gene mutations initially classified as VUS, as potentially pathogenetic. Our proof-of-concept showed a potential application of AlphaFold as tool to a better inform VUS interpretation of genetic tests.
Asunto(s)
Esclerosis Amiotrófica Lateral , Humanos , Femenino , Inteligencia Artificial , Proteínas Portadoras , Glicoproteínas/genética , MutaciónRESUMEN
OBJECTIVES: Calibration is an important source of variability in liquid chromatography mass spectrometry (LC-MS) methods for insulin-like growth factor 1 (IGF-1). This study investigated the impact of different calibrator matrices on IGF-1 measurements by LC-MS. Moreover, the comparability of immunoassays and LC-MS was assessed. DESIGN & METHODS: Calibrators from 12.5 to 2009 ng/ml were prepared by spiking WHO international Standard (ID 02/254 NIBSC, UK) into the following matrices: native human plasma, fresh charcoal-treated human plasma (FCTHP), old charcoal-treated human plasma, deionized water, bovine serum albumin (BSA), and rat plasma (RP). A validated in-house LC-MS method was calibrated repeatedly with these calibrators. Then, serum samples from 197 growth hormone excess and deficiency patients were analysed with each calibration. RESULTS: The seven calibration curves had different slopes leading to markedly different patient results. The largest differences in IGF-1 concentration from the median (interquartile range) was observed with the calibrator in water and the calibrator in RP (336.4 [279.6-417.0] vs. 112.5 [71.2-171.2], p < 0.001). The smallest difference was observed with calibrators in FCTHP and BSA (141.8 [102.0-198.5] vs. 127.9 [86.9-186.0], p < 0.049). Compared to LC-MS with calibrators in FCTHP, immunoassays showed relevant proportional bias (range: -43% to -68%), constant bias (range: 22.84 to 57.29 ng/ml) and pronounced scatter. Comparing the immunoassays with each other revealed proportional bias of up to 24%. CONCLUSIONS: The calibrator matrix is critical for the measurement of IGF-1 by LC-MS. Regardless of the calibrator matrix, LC-MS shows poor agreement with immunoassays. Also, the agreement between different immunoassays is variable.
Asunto(s)
Acromegalia , Factor I del Crecimiento Similar a la Insulina , Humanos , Animales , Ratas , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Hormona del Crecimiento , Calibración , Carbón OrgánicoRESUMEN
Tooth morphogenesis requires sequential and reciprocal interactions between the cranial neural crest-derived mesenchymal cells and the stomadial epithelium, which regulate tooth morphogenesis and differentiation. We show how mesenchyme-derived single stem cell populations can be induced to transdifferentiate in vitro in a structure similar to a dental bud. The presence of stem cells in the adipose tissue has been previously reported. We incubated primary cultures of human adipose tissue-derived stem cells in a dental-inducing medium and cultured the aggregates in three-dimensional conditions. Four weeks later, cells formed a three-dimensional organized structure similar to a dental bud. Expression of dental tissue-related markers was tested assaying lineage-specific mRNA and proteins by RT-PCR, immunoblot, IHC, and physical-chemical analysis. In the induction medium, cells were positive for ameloblastic and odontoblastic markers as both mRNAs and proteins. Also, cells expressed epithelial, mesenchymal, and basement membrane markers with a positional relationship similar to the physiologic dental morphogenesis. Physical-chemical analysis revealed 200-nm and 50-nm oriented hydroxyapatite crystals as displayed in vivo by enamel and dentin, respectively. In conclusion, we show that adipose tissue-derived stem cells in vitro can transdifferentiate to produce a specific three-dimensional organization and phenotype resembling a dental bud even in the absence of structural matrix or scaffold to guide the developmental process.