RESUMEN
While evidence exists supporting the potential for aerosol transmission of SARS-CoV-2, the infectious dose by inhalation remains unknown. In the present study, the probability of infection following inhalation of SARS-CoV-2 was dose-dependent in a nonhuman primate model of inhalational COVID-19. The median infectious dose, assessed by seroconversion, was 52 TCID50 (95% CI: 23-363 TCID50), and was significantly lower than the median dose for fever (256 TCID50, 95% CI: 102-603 TCID50), resulting in a group of animals that developed an immune response post-exposure but did not develop fever or other clinical signs of infection. In a subset of these animals, virus was detected in nasopharyngeal and/or oropharyngeal swabs, suggesting that infected animals without signs of disease are able to shed virus and may be infectious, which is consistent with reports of asymptomatic spread in human cases of COVID-19. These results suggest that differences in exposure dose may be a factor influencing disease presentation in humans, and reinforce the importance of public health measures that limit exposure dose, such as social distancing, masking, and increased ventilation. The dose-response data provided by this study are important to inform disease transmission and hazard modeling, and, ultimately, mitigation strategies. Additionally, these data will be useful to inform dose selection in future studies examining the efficacy of therapeutics and vaccines against inhalational COVID-19, and as a baseline in healthy, young adult animals for assessment of the importance of other factors, such as age, comorbidities, and viral variant, on the infectious dose and disease presentation.
Asunto(s)
COVID-19/transmisión , COVID-19/virología , Macaca fascicularis , Seroconversión , Animales , Chlorocebus aethiops , Modelos Animales de Enfermedad , Femenino , Fiebre/virología , Exposición por Inhalación , Masculino , Células Vero , Carga ViralRESUMEN
BACKGROUND: Our laboratory previously examined the influence of environmental conditions on the stability of an early isolate of SARS-CoV-2 (hCoV-19/USA/WA-1/2020) in aerosols generated from culture medium or simulated saliva. However, genetic differences have emerged among SARS-CoV-2 lineages, and it is possible that these differences may affect environmental stability and the potential for aerosol transmission. METHODS: The influence of temperature, relative humidity, and simulated sunlight on the decay of 4 SARS-CoV-2 isolates in aerosols, including 1 belonging to the recently emerged B.1.1.7 lineage, were compared in a rotating drum chamber. Aerosols were generated from simulated respiratory tract lining fluid to represent aerosols originating from the deep lung. RESULTS: No differences in the stability of the isolates were observed in the absence of simulated sunlight at either 20°C or 40°C. However, a small but statistically significant difference in the stability was observed between some isolates in simulated sunlight at 20°C and 20% relative humidity. CONCLUSIONS: The stability of SARS-CoV-2 in aerosols does not vary greatly among currently circulating lineages, including B.1.1.7, suggesting that the increased transmissibility associated with recent SARS-CoV-2 lineages is not due to enhanced survival in the environment.
Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Humedad , Aerosoles y Gotitas RespiratoriasRESUMEN
OBJECTIVE: For many agents, the aerodynamic particle size can affect both the virulence and disease course in animal models. Botulinum neurotoxins (BoNTs), which are widely known as potential bioterrorism agents, have been shown to be toxic via multiple routes of exposure, including small particle inhalation (1-3 µm MMAD). However, the impact of larger particle sizes on the potency of BoNT has not been previously reported. In this study, we compared the potency of BoNT in small and large particle aerosols. MATERIALS AND METHODS: Outbred mice (ICR (CD-1®)) were exposed to BoNT-containing aerosols with differing mass median aerodynamic diameters (MMADs) of 1.1, 4.9, and 7.6 microns. The effects of bioaerosol sampler and inhalation exposure modality were studied. RESULTS AND DISCUSSION: Collecting aerosolized BoNT onto gelatin filters or into liquid impingers resulted in equivalent estimates of aerosol concentration. Nose-only and whole-body inhalation exposure resulted in nearly identical estimates of the median lethal dose (LD50). The LD50 for inhaled BoNT increased approximately 50-fold when the median aerodynamic particle size was increased from 1.1 to 4.9 µm, from 139 (95% CI: 111-185) to 7324 (95% CI: 4287-10 891) mouse intraperitoneal median lethal doses (MIPLD50). These results demonstrate the importance of aerodynamic particle size and regional deposition patterns with regards to BoNT inhalational toxicity. CONCLUSIONS: These data will be useful for medical countermeasure development, as well as biodefense preparedness modeling by demonstrating that the estimates of dose and toxicity of an inhaled aerosol containing BoNT can be significantly affected by a range of factors.
Asunto(s)
Contaminantes Atmosféricos/toxicidad , Toxinas Botulínicas/administración & dosificación , Toxinas Botulínicas/toxicidad , Tamaño de la Partícula , Animales , Exposición por Inhalación , Dosificación Letal Mediana , RatonesRESUMEN
In the absence of a vaccine, preventing the spread of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the primary means to reduce the impact of the 2019 coronavirus disease (COVID-19). Multiple studies have reported the presence of SARS-CoV-2 genetic material on surfaces suggesting that fomite transmission of SARS-CoV-2 is feasible. High temperature inactivation of virus has been previously suggested, but not shown. In the present study, we investigated the environmental stability of SARS-CoV-2 in a clinically relevant matrix dried onto stainless steel at a high temperature. The results show that at 54.5 °C, the virus half-life was 10.8 ± 3.0 min and the time for a 90% decrease in infectivity was 35.4 ± 9.0 min. These findings suggest that in instances where the environment can reach temperatures of at least 54.5 °C, such as in vehicle interior cabins when parked in warmer ambient air, that the potential for exposure to infectious virus on surfaces could be decreased substantially in under an hour.
RESUMEN
BACKGROUND: Environmental parameters, including sunlight levels, are known to affect the survival of many microorganisms in aerosols. However, the impact of sunlight on the survival of influenza virus in aerosols has not been previously quantified. METHODS: The present study examined the influence of simulated sunlight on the survival of influenza virus in aerosols at both 20% and 70% relative humidity using an environmentally controlled rotating drum aerosol chamber. RESULTS: Measured decay rates were dependent on the level of simulated sunlight, but they were not significantly different between the 2 relative humidity levels tested. In darkness, the average decay constant was 0.02 ± 0.06 min-1, equivalent to a half-life of 31.6 minutes. However, at full intensity simulated sunlight, the mean decay constant was 0.29 ± 0.09 min-1, equivalent to a half-life of approximately 2.4 minutes. CONCLUSIONS: These results are consistent with epidemiological findings that sunlight levels are inversely correlated with influenza transmission, and they can be used to better understand the potential for the virus to spread under varied environmental conditions.
Asunto(s)
Subtipo H1N1 del Virus de la Influenza A/efectos de la radiación , Infecciones por Orthomyxoviridae/transmisión , Infecciones por Orthomyxoviridae/virología , Luz Solar , Rayos Ultravioleta , Aerosoles , Animales , Perros , Humedad , Células de Riñón Canino Madin Darby , TemperaturaRESUMEN
Previous studies have demonstrated that SARS-CoV-2 is stable on surfaces for extended periods under indoor conditions. In the present study, simulated sunlight rapidly inactivated SARS-CoV-2 suspended in either simulated saliva or culture media and dried on stainless steel coupons. Ninety percent of infectious virus was inactivated every 6.8 minutes in simulated saliva and every 14.3 minutes in culture media when exposed to simulated sunlight representative of the summer solstice at 40°N latitude at sea level on a clear day. Significant inactivation also occurred, albeit at a slower rate, under lower simulated sunlight levels. The present study provides the first evidence that sunlight may rapidly inactivate SARS-CoV-2 on surfaces, suggesting that persistence, and subsequently exposure risk, may vary significantly between indoor and outdoor environments. Additionally, these data indicate that natural sunlight may be effective as a disinfectant for contaminated nonporous materials.
Asunto(s)
Betacoronavirus , Infecciones por Coronavirus , Pandemias , Neumonía Viral , Coronavirus Relacionado al Síndrome Respiratorio Agudo Severo , COVID-19 , Humanos , SARS-CoV-2 , Luz SolarRESUMEN
Aerosols represent a potential transmission route of COVID-19. This study examined effect of simulated sunlight, relative humidity, and suspension matrix on stability of SARS-CoV-2 in aerosols. Simulated sunlight and matrix significantly affected decay rate of the virus. Relative humidity alone did not affect the decay rate; however, minor interactions between relative humidity and other factors were observed. Mean decay rates (± SD) in simulated saliva, under simulated sunlight levels representative of late winter/early fall and summer were 0.121â ±â 0.017 min-1 (90% loss, 19 minutes) and 0.306â ±â 0.097 min-1 (90% loss, 8 minutes), respectively. Mean decay rate without simulated sunlight across all relative humidity levels was 0.008â ±â 0.011 min-1 (90% loss, 286 minutes). These results suggest that the potential for aerosol transmission of SARS-CoV-2 may be dependent on environmental conditions, particularly sunlight. These data may be useful to inform mitigation strategies to minimize the potential for aerosol transmission.
Asunto(s)
Microbiología del Aire , Betacoronavirus/efectos de la radiación , Infecciones por Coronavirus/transmisión , Neumonía Viral/transmisión , Luz Solar , Aerosoles , Animales , COVID-19 , Chlorocebus aethiops , Simulación por Computador , Medios de Cultivo , Humedad , Concentración de Iones de Hidrógeno , Pandemias , Análisis de Regresión , SARS-CoV-2 , Saliva/química , Saliva/virología , Células VeroRESUMEN
UNLABELLED: Public health and decontamination decisions following an event that causes indoor contamination with a biological agent require knowledge of the environmental persistence of the agent. The goals of this study were to develop methods for experimentally depositing bacteria onto indoor surfaces via aerosol, evaluate methods for sampling and enumerating the agent on surfaces, and use these methods to determine bacterial surface decay. A specialized aerosol deposition chamber was constructed, and methods were established for reproducible and uniform aerosol deposition of bacteria onto four coupon types. The deposition chamber facilitated the control of relative humidity (RH; 10 to 70%) following particle deposition to mimic the conditions of indoor environments, as RH is not controlled by standard heating, ventilation, and air conditioning (HVAC) systems. Extraction and culture-based enumeration methods to quantify the viable bacteria on coupons were shown to be highly sensitive and reproducible. To demonstrate the usefulness of the system for decay studies,Yersinia pestis persistence as a function of surface type at 21 °C and 40% RH was determined to be >40%/min for all surfaces. Based upon these results, at typical indoor temperature and RH, a 6-log reduction in titer would expected to be achieved within 1 h as the result of environmental decay on surfaces without active decontamination. The developed approach will facilitate future persistence and decontamination studies with a broad range of biological agents and surfaces, providing agent decay data to inform both assessments of risk to personnel entering a contaminated site and decontamination decisions following biological contamination of an indoor environment. IMPORTANCE: Public health and decontamination decisions following contamination of an indoor environment with a biological agent require knowledge of the environmental persistence of the agent. Previous studies on Y. pestis persistence have utilized large liquid droplet deposition to provide persistence data. As a result, methods were developed to deposit aerosols containing bacteria onto indoor surfaces, reproducibly enumerate bacteria harvested from coupons, and determine surface decay utilizing Y. pestis The results of this study provide foundational methods required to evaluate surface decay of bacteria and potentially other biological agents, such as viruses, in aerosol particles as a function of surface type and environment. Integrating the data from both aerosol and liquid deposition surface decay studies will provide medical and public health personnel with a more complete understanding of agent persistence on surfaces in contaminated areas for assessment of health risks and to inform decontamination decisions.
Asunto(s)
Monitoreo del Ambiente/métodos , Yersinia pestis/aislamiento & purificación , Aerosoles , Contaminación del Aire Interior/análisis , Descontaminación/métodos , Microbiología Ambiental , Monitoreo del Ambiente/instrumentación , Contaminación de Equipos , Diseño de Equipo , Calefacción , Humedad , Viabilidad Microbiana , Tamaño de la Partícula , Sonicación/métodos , Esporas Bacterianas/aislamiento & purificación , Propiedades de Superficie , TemperaturaRESUMEN
Background: Significant evidence suggests that SARS-CoV-2 can be transmitted via respiratory aerosols, which are known to vary as a function of respiratory activity. Most animal models examine disease presentation following inhalation of small-particle aerosols similar to those generated during quiet breathing or speaking. However, despite evidence that particle size can influence dose-infectivity relationships and disease presentation for other microorganisms, no studies have examined the infectivity of SARS-CoV-2 contained in larger particle aerosols similar to those produced during coughing, singing, or talking. Therefore, the aim of the present study was to assess the influence of aerodynamic diameter on the infectivity and virulence of aerosols containing SARS-CoV-2 in a hamster model of inhalational COVID-19. Methods: Dose-response relationships were assessed for two different aerosol particle size distributions, with mass median aerodynamic diameters (MMADs) of 1.3 and 5.2 µm in groups of Syrian hamsters exposed to aerosols containing SARS-CoV-2. Results: Disease was characterized by viral shedding in oropharyngeal swabs, increased respiratory rate, decreased activity, and decreased weight gain. Aerosol particle size significantly influenced the median doses to induce seroconversion and viral shedding, with both increasing â¼30-fold when the MMAD was increased. In addition, disease presentation was dose-dependent, with seroconversion and viral shedding occurring at lower doses than symptomatic disease characterized by increased respiratory rate and decreased activity. Conclusions: These results suggest that aerosol particle size may be an important factor influencing the risk of COVID-19 transmission and needs to be considered when developing animal models of disease. This result agrees with numerous previous studies with other microorganisms and animal species, suggesting that it would be generally translatable across different species. However, it should be noted that the absolute magnitude of the observed shifts in the median doses obtained with the specific particle sizes utilized herein may not be directly applicable to other species.
Asunto(s)
COVID-19 , Animales , Cricetinae , Mesocricetus , Administración por Inhalación , Tamaño de la Partícula , SARS-CoV-2 , Aerosoles y Gotitas Respiratorias , Gravedad del PacienteRESUMEN
Burkholderia pseudomallei, the causative agent of melioidosis, is recognized as a serious health threat due to its involvement in septic and pulmonary infections in areas of endemicity and is recognized by the Centers for Disease Control and Prevention as a category B biothreat agent. An animal model is desirable to evaluate the pathogenesis of melioidosis and medical countermeasures. A model system that represents human melioidosis infections is essential in this process. A group of 10 rhesus macaques (RMs) and 10 African green monkeys (AGMs) was exposed to aerosolized B. pseudomallei 1026b. The first clinical signs were fever developing 24 to 40 h postexposure followed by leukocytosis resulting from a high percentage of neutrophils. Dyspnea manifested 2 to 4 days postexposure. In the AGMs, an increase in interleukin 1ß (IL-1ß), IL-6, IL-8, gamma interferon (IFN-γ), and tumor necrosis factor alpha (TNF-α) was observed. In the RMs, IL-1ß, IL-6, and TNF-α increased. All the RMs and AGMs had various degrees of bronchopneumonia, with inflammation consisting of numerous neutrophils and a moderate number of macrophages. Both the RMs and the AGMs appear to develop a melioidosis infection that closely resembles that seen in acute human melioidosis. However, for an evaluation of medical countermeasures, AGMs appear to be a more appropriate model.
Asunto(s)
Bronconeumonía/fisiopatología , Burkholderia pseudomallei/fisiología , Chlorocebus aethiops , Modelos Animales de Enfermedad , Macaca mulatta , Melioidosis/fisiopatología , Animales , Bronconeumonía/patología , Citocinas/metabolismo , Pulmón/patología , Masculino , Melioidosis/patologíaRESUMEN
Previous studies have demonstrated that aerosol sampling devices can have deleterious effects on bacteria due to stresses intrinsic to the sampling processes. Although a significant amount of work has been carried out to develop animal models of inhalational melioidosis, little information has been reported on the effects of the aerosol sampling devices on the causative bacterium, Burkholderia pseudomallei. The aim of this study was to compare the efficiencies for collection of aerosolized bacteria in three sampling devices that have been used in studies utilizing aerosolized B. pseudomallei. The data from this study demonstrate the equivalence of the Mercer impactor, gelatin filter, and model 7541 AGI for sampling respirable aerosols containing B. pseudomallei across a range of aerosol concentrations. It was also determined that the retention efficiency of gelatin filters for culturable B. pseudomallei was near unity, suggesting that desiccation of collected material did not occur for the short sampling period tested. The retention efficiency of the model 7541 AGI for culturable B. pseudomallei was significantly less than unity, and it was determined that this decrease was likely due to the stresses associated with repetitive sampler bubbling. The results of this study also confirmed the results of previous studies on the deleterious effects of the Collison nebulizer on microorganisms and extended these data to include B. pseudomallei.
Asunto(s)
Técnicas Bacteriológicas/instrumentación , Burkholderia pseudomallei/aislamiento & purificación , Nebulizadores y Vaporizadores , Aerosoles , Carga Bacteriana , Burkholderia pseudomallei/crecimiento & desarrolloRESUMEN
Numerous studies have demonstrated that SARS-CoV-2 can be inactivated by ultraviolet (UV) radiation. However, there are few data available on the relative efficacy of different wavelengths of UV radiation and visible light, which complicates assessments of UV decontamination interventions. The present study evaluated the effects of monochromatic radiation at 16 wavelengths from 222 nm through 488 nm on SARS-CoV-2 in liquid aliquots and dried droplets of water and simulated saliva. The data were used to generate a set of action spectra which quantify the susceptibility of SARS-CoV-2 to genome damage and inactivation across the tested wavelengths. UVC wavelengths (≤280 nm) were most effective for inactivating SARS-CoV-2, although inactivation rates were dependent on sample type. Results from this study suggest that UV radiation can effectively inactivate SARS-CoV-2 in liquids and dried droplets, and provide a foundation for understanding the factors which affect the efficacy of different wavelengths in real-world settings.
Asunto(s)
COVID-19 , SARS-CoV-2 , Desinfección/métodos , Humanos , Luz , Rayos Ultravioleta , Inactivación de Virus/efectos de la radiaciónRESUMEN
Background: As the COVID-19 pandemic has progressed, numerous variants of SARS-CoV-2 have arisen, with several displaying increased transmissibility. Methods: The present study compared dose-response relationships and disease presentation in nonhuman primates infected with aerosols containing an isolate of the Gamma variant of SARS-CoV-2 to the results of our previous study with the earlier WA-1 isolate of SARS-CoV-2. Results: Disease in Gamma-infected animals was mild, characterized by dose-dependent fever and oronasal shedding of virus. Differences were observed in shedding in the upper respiratory tract between Gamma- and WA-1-infected animals that have the potential to influence disease transmission. Specifically, the estimated median doses for shedding of viral RNA or infectious virus in nasal swabs were approximately 10-fold lower for the Gamma variant than the WA-1 isolate. Given that the median doses for fever were similar, this suggests that there is a greater difference between the median doses for viral shedding and fever for Gamma than for WA-1 and potentially an increased range of doses for Gamma over which asymptomatic shedding and disease transmission are possible. Conclusions: These results complement those of previous studies, which suggested that differences in exposure dose may help to explain the range of clinical disease presentations observed in individuals with COVID-19, highlighting the importance of public health measures designed to limit exposure dose, such as masking and social distancing. The dose-response data provided by this study are important to inform disease transmission and hazard modeling, as well as to inform dose selection in future studies examining the efficacy of therapeutics and vaccines in animal models of inhalational COVID-19.
Asunto(s)
COVID-19 , SARS-CoV-2 , Animales , Humanos , Pandemias/prevención & control , Administración por Inhalación , PrimatesRESUMEN
Previous field and laboratory studies investigating airborne Burkholderia pseudomallei have used a variety of different aerosol samplers to detect and quantify concentrations of the bacteria in aerosols. However, the performance of aerosol samplers can vary in their ability to preserve the viability of collected microorganisms, depending on the resistance of the organisms to impaction, desiccation, or other stresses associated with the sampling process. Consequently, sampler selection is critical to maximizing the probability of detecting viable microorganisms in collected air samples in field studies and for accurate determination of aerosol concentrations in laboratory studies. To inform such decisions, the present study assessed the performance of four laboratory aerosol samplers, specifically the all-glass impinger (AGI), gelatin filter, midget impinger, and Mercer cascade impactor, for collecting aerosols containing B. pseudomallei generated from suspensions in two types of culture media. The results suggest that the relative performance of the sampling devices is dependent on the suspension medium utilized for aerosolization. Performance across the four samplers was similar for aerosols generated from suspensions supplemented with 4% glycerol. However, for aerosols generated from suspensions without glycerol, use of the filter sampler or an impactor resulted in significantly lower estimates of the viable aerosol concentration than those obtained with either the AGI or midget impinger. These results demonstrate that sampler selection has the potential to affect estimation of doses in inhalational animal models of melioidosis, as well as the likelihood of detection of viable B. pseudomallei in the environment, and will be useful to inform design of future laboratory and field studies.
Asunto(s)
Técnicas Bacteriológicas/instrumentación , Burkholderia pseudomallei/aislamiento & purificación , Nebulizadores y Vaporizadores , Aerosoles , Carga Bacteriana , Burkholderia pseudomallei/crecimiento & desarrolloRESUMEN
To assess the risk of aerosol transmission of SARS-CoV-2, measurements of the airborne viral concentrations in proximity to infected individuals, the persistence of the virus in aerosols, and the dose of the virus needed to cause infection following inhalation are required. For studies aimed at quantifying these parameters, an aerosol sampling device needs to be employed. A number of recent studies have reported the detection of both genetic material and infectious SARS-CoV-2 virus in air samples collected in clinical settings. Previous studies have demonstrated that the efficiency of different samplers for collection and preservation of the infectivity of microorganisms can vary as a function of the specific microorganism. In the present study, the performance of eight common low-flow aerosol sampling devices were compared for their ability to collect and preserve the infectivity of airborne SARS-CoV-2 contained in small particle aerosols. The influence of sampling duration on recovery of infectious virus was also evaluated. Similar concentrations of infectious SARS-CoV-2 were measured in aerosols for the majority of the samplers tested, with the exception of the midget impingers, which measured significantly lower concentrations of SARS-CoV-2. Additionally, in three of the four impingers tested, additional clean airflow through the device following collection of infectious virus resulted in a decrease of the infectious concentration of virus over time, suggesting that virus was being inactivated and these devices may not be suitable for sampling for long durations. Further, RNA copies in the samples over time did not correspond with the losses of infectious SARS-CoV-2 observed in the impingers samples. These data can be utilized to inform interpretation of current studies on the SARS-CoV-2 viral loads in air samples, as well as inform sampling device selection in future studies.
RESUMEN
A variety of methods have been developed for quantification of infectious Ebola virus in clinical or laboratory samples, but existing methods often require extensive operator involvement, manual assay scoring, or the use of custom reagents. In this study, we utilize a recently developed Ebola-specific reporter cell line that expresses ZsGreen in response to Ebola virus infection, in conjunction with semi-automated processing and quantification techniques, to develop an unbiased, high-throughput microtitration assay for quantification of infectious Ebola virus in vitro. This assay was found to have equivalent sensitivity to a standardized plaque assay for quantifying viral titers. However, the new assay could be implemented with fewer reagents and processing steps, reduced subjectivity, and higher throughput. This assay may be useful for a variety of applications, particularly studies that require the detection or quantification of infectious Ebola virus in large numbers of samples.
Asunto(s)
Ebolavirus , Fiebre Hemorrágica Ebola , Línea Celular , Fiebre Hemorrágica Ebola/diagnóstico , Ensayos Analíticos de Alto Rendimiento , HumanosRESUMEN
Recent evidence suggests that respiratory aerosols may play a role in the spread of SARS-CoV-2 during the ongoing COVID-19 pandemic. Our laboratory has previously demonstrated that simulated sunlight inactivated SARS-CoV-2 in aerosols and on surfaces. In the present study, we extend these findings to include the persistence of SARS-CoV-2 in aerosols across a range of temperature, humidity, and simulated sunlight levels using an environmentally controlled rotating drum aerosol chamber. The results demonstrate that temperature, simulated sunlight, and humidity are all significant factors influencing the persistence of infectious SARS-CoV-2 in aerosols, but that simulated sunlight and temperature have a greater influence on decay than humidity across the range of conditions tested. The time needed for a 90% decrease in infectious virus ranged from 4.8 min at 40 °C, 20% relative humidity, and high intensity simulated sunlight representative of noon on a clear day on the summer solstice at 4°N latitude, to greater than two hours under conditions representative of those expected indoors or at night. These results suggest that the persistence of infectious SARS-CoV-2 in naturally occurring aerosols may be affected by environmental conditions, and that aerosolized virus could remain infectious for extended periods of time under some environmental conditions. The present study provides a comprehensive dataset on the influence of environmental parameters on the survival of SARS-CoV-2 in aerosols that can be utilized, along with data on viral shedding from infected individuals and the inhalational infectious dose, to inform future modeling and risk assessment efforts.
RESUMEN
Coronavirus disease 2019 (COVID-19) was first identified in China in late 2019 and is caused by newly identified severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Previous studies had reported the stability of SARS-CoV-2 in cell culture media and deposited onto surfaces under a limited set of environmental conditions. Here, we broadly investigated the effects of relative humidity, temperature, and droplet size on the stability of SARS-CoV-2 in a simulated clinically relevant matrix dried on nonporous surfaces. The results show that SARS-CoV-2 decayed more rapidly when either humidity or temperature was increased but that droplet volume (1 to 50 µl) and surface type (stainless steel, plastic, or nitrile glove) did not significantly impact decay rate. At room temperature (24°C), virus half-life ranged from 6.3 to 18.6 h depending on the relative humidity but was reduced to 1.0 to 8.9 h when the temperature was increased to 35°C. These findings suggest that a potential for fomite transmission may persist for hours to days in indoor environments and have implications for assessment of the risk posed by surface contamination in indoor environments.IMPORTANCE Mitigating the transmission of SARS-CoV-2 in clinical settings and public spaces is critically important to reduce the number of COVID-19 cases while effective vaccines and therapeutics are under development. SARS-CoV-2 transmission is thought to primarily occur through direct person-to-person transfer of infectious respiratory droplets or through aerosol-generating medical procedures. However, contact with contaminated surfaces may also play a significant role. In this context, understanding the factors contributing to SARS-CoV-2 persistence on surfaces will enable a more accurate estimation of the risk of contact transmission and inform mitigation strategies. To this end, we have developed a simple mathematical model that can be used to estimate virus decay on nonporous surfaces under a range of conditions and which may be utilized operationally to identify indoor environments in which the virus is most persistent.
Asunto(s)
Fómites/virología , Humedad , Modelos Teóricos , Coronavirus Relacionado al Síndrome Respiratorio Agudo Severo/fisiología , Temperatura , Inactivación de Virus , Contaminación del Aire Interior , COVID-19 , Infecciones por Coronavirus/prevención & control , Infecciones por Coronavirus/transmisión , Infecciones por Coronavirus/virología , Semivida , Humanos , Pandemias/prevención & control , Plásticos , Neumonía Viral/prevención & control , Neumonía Viral/transmisión , Neumonía Viral/virología , Porosidad , Saliva/química , Saliva/virología , Acero Inoxidable , Propiedades de SuperficieRESUMEN
Human serum butyrylcholinesterase (Hu BChE) is currently under advanced development as a pretreatment drug for organophosphate (OP) poisoning in humans. It was shown to protect mice, rats, guinea pigs, and monkeys against multiple LD(50) challenges of OP nerve agents by i.v. or s.c. bolus injections. Since inhalation is the most likely route of exposure to OP nerve agents on the battlefield or in public places, the aim of this study was to evaluate the efficacy of Hu BChE against whole-body inhalation exposure to sarin (GB) vapor. Male Göttingen minipigs were subjected to one of the following treatments: (1) air exposure; (2) GB vapor exposure; (3) pretreatment with 3 mg/kg of Hu BChE followed by GB vapor exposure; (4) pretreatment with 6.5 mg/kg of Hu BChE followed by GB vapor exposure; (5) pretreatment with 7.5 mg/kg of Hu BChE followed by GB vapor exposure. Hu BChE was administered by i.m. injection, 24h prior to whole-body exposure to GB vapor at a concentration of 4.1 mg/m(3) for 60 min, a dose lethal to 99% of untreated exposed pigs (LCt99). EEG, ECG, and pupil size were monitored throughout exposure, and blood drawn from a surgically implanted jugular catheter before and throughout the exposure period, was analyzed for acetylcholinesterase (AChE) and BChE activities, and the amount of GB present in plasma. All animals exposed to GB vapor alone or pretreated with 3 or 6.5 mg/kg of Hu BChE, died following exposure to GB vapor. All five animals pretreated with 7.5 mg/kg of Hu BChE survived the GB exposure. The amount of GB bound in plasma was 200-fold higher compared to that from plasma of pigs that did not receive Hu BChE, suggesting that Hu BChE was effective in scavenging GB in blood. Additionally, pretreatment with 7.5 mg/kg of Hu BChE prevented cardiac abnormalities and seizure activity observed in untreated animals and those treated with lower doses of Hu BChE.
Asunto(s)
Antídotos/uso terapéutico , Butirilcolinesterasa/sangre , Butirilcolinesterasa/uso terapéutico , Sustancias para la Guerra Química/toxicidad , Sarín/toxicidad , Animales , Disponibilidad Biológica , Butirilcolinesterasa/farmacocinética , Humanos , Masculino , Porcinos , Porcinos EnanosRESUMEN
Using a modified noninvasive volume-displacement plethysmography system, we investigated the effects of inhaled dichlorvos (2,2-dimethyl-dichlorovinyl phosphate, or DDVP) vapor on the respiratory mechanics and blood cholinesterase activity of guinea pigs. Data revealed significant dose-dependent changes in several pulmonary parameters. Animals exposed to a DDVP concentration of 35 mg/m(3) did not show any significant changes in frequency, tidal volume, or minute ventilation. However, animals exposed to 55 mg/m(3) DDVP showed significantly decreased respiratory frequency and significantly increased tidal volume with no significant changes in minute ventilation. Similarly, animals exposed to 75 mg/m(3) DDVP showed significantly decreased respiratory frequency along with significantly increased tidal volume. The decreased respiratory frequency was large enough in the high exposure group to offset the increased tidal volume. This effect resulted in significantly decreased minute ventilation by the end of exposure, which remained attenuated 10 min after exposure. An analysis of whole-blood cholinesterase activity revealed significantly decreased activity for both acetylcholinesterase (AChE) and butyl-cholinesterase (BChE). Peak inhibition occurred for both enzymes at the end of exposure for all three concentrations and rapidly recovered within several minutes of exposure. Analysis of blood samples using gas chromatography-mass spectroscopy (GC-MS) revealed that minute ventilation may only play a minimal role in the dosimetry of inhaled DDVP vapor.