Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Arthroscopy ; 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38986851

RESUMEN

PURPOSE: To assess the consistency and quality of risk factor reporting for rotator cuff repair (RCR) retear and identify risk factors most frequently associated with retear. METHODS: A systematic review was performed according to Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Of the initial 3,158 studies, a total of 31 met the following inclusion criteria: (1) clinical studies regarding RCR failure, (2) arthroscopic procedures involving RCR, (3) reporting of clinical outcomes, (4) publication within the past 5 years, and (5) studies investigating preoperative risk factors for retear. After full-text review, 18 risk factors were analyzed. RESULTS: The most consistently significant risk factors were acromiohumeral distance (80%), critical shoulder angle (67%), tear size (63%), anterior-posterior dimension (60%), fatty infiltration (FI) (58%), and retraction size (56%). FI was analyzed using different methods among studies, with 63% finding significant results and 50% of all studies performing ordinal analysis. Tear size was inconsistently analyzed quantitatively or qualitatively, with 58% of studies finding significant results and 63% of all studies performing quantitative analysis. Risk factors consistently found to be nonsignificant included age, sex, diabetes mellitus, symptom duration, hand dominance, repair technique, smoking, and body mass index. CONCLUSIONS: Tear size, FI, and retraction size were found to be significant risk factors in most of the included studies evaluating rotator cuff retear. Risk factors less likely reported as predictive included repair technique, age, sex, diabetes mellitus, symptom duration, hand dominance, repair technique, smoking, and body mass index. Risk factors that require further investigation include critical shoulder angle, acromiohumeral distance, and anterior-posterior tear dimension. LEVEL OF EVIDENCE: Level III, systematic review of Level III-IV studies.

2.
Arthroscopy ; 2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38008388

RESUMEN

PURPOSE: To identify frequently studied significant preoperative risk factors for meniscal allograft transplantation (MAT) failure. METHODS: Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines were used to conduct this systematic review. The database analysis was performed in May of 2022 and included PubMed, Embrace, and Cochrane. Studies between January 1, 2000, and January 1, 2021, were reviewed with search terms, including "meniscal," "meniscus," "transplantation," "transplant," and "allograft." Twenty-one full-text manuscripts met inclusion criteria of studies assessing preoperative risk factors for MAT failure defined as either clinical failure (Lysholm <65) or surgical failure (revision, removal, or conversion to knee arthroplasty). RESULTS: In total, 21 studies were included, comprising 47.6% with a Level of Evidence of Level III and 52.4% with Level of Evidence IV. The analysis involved 2,533 patients, and the mean final follow-up ranged from 2.2 to 20.0 years. The presence of high-grade cartilage defects was the only factor found predictive of MAT surgical failure in the majority of studies in which it was analyzed (5/7 studies, 71.4%). Four of the five studies that found high-grade cartilage defects to be a predictor of MAT surgical failure did not treat all cartilage lesions, while the 2 studies that found high-grade cartilage defects an insignificant predictor of MAT surgical failure treated all defects at the time of MAT. For clinical failure, no risk factors were predictive of MAT failure in the majority of studies, although smoking and concomitant ligamentous or realignment procedures were significant in 1 study. CONCLUSION: The presence of untreated high-grade cartilage appears to elevate the risk of surgical MAT failure; however, concomitant treatment of defects may mitigate their detrimental effect. There is no clear risk factor that consistently predicts clinical failure. Age, sex, BMI, knee compartment, time from prior meniscectomy, femorotibial alignment (after correction), concomitant cartilage procedure, and laterality do not routinely impact MAT failure. LEVEL OF EVIDENCE: Level IV, systematic review.

3.
Arthroscopy ; 39(6): 1483-1489.e1, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36567182

RESUMEN

PURPOSE: The purpose of this study was to compare failure rates and patient-reported outcomes between transosseus (TO) suture and suture anchor (SA) quadriceps tendon repairs. METHODS: Following institutional review board approval, patients who underwent primary repair for quadriceps tendon rupture with TO or SA techniques between January 2009 and August 2018 were identified from an institutional database and retrospectively reviewed. Patients were contacted for satisfaction (1-10 scale), current function (0-100 scale), failure (retear), and revision surgeries; International Knee Documentation Committee (IKDC) score and Knee Injury and Osteoarthritis Outcomes Score (KOOS) were also collected to achieve a minimum of 2-year follow-up. RESULTS: Sixty-four patients (34 SA, 30 TO) were available by phone or e-mail at a mean of 4.81 ± 2.60 years postoperatively. There were 10 failures, for an overall failure rate of 15.6%. Failure incidence did not significantly differ between treatment groups (P = .83). Twenty-seven patients (47% of nonfailed patients) had completed patient-reported outcomes. The SA group reported higher subjective function (SA: 90 [85-100] vs TO: 85 [60-93], 95% CI of difference: -19.9 to -2.1 × 10-5, P = .042), final IKDC (79.6 [50.0-93.6] vs 62.1 [44.3-65.5], 95% CI of difference: -33.0 to -0.48, P = .048), KOOS Pain (97.2 [84.7-97.2] vs 73.6 [50.7-88.2], 95% CI of difference: -36.1 to -3.6 × 10-5, P = .037), Quality of Life (81.3 [56.3-93.8] vs 50.0 [23.4-56.3], 95% CI of difference: -50.0 to -6.2, P = .026), and Sport (75.0 [52.5-90.0] vs 47.5 [31.3-67.5], 95% CI of the difference: -45.0 to -4.1 × 10-5, P = .048). CONCLUSIONS: There is no significant difference in failure rate between transosseus and suture anchor repairs for quadriceps tendon ruptures (P = .83). Most failures occur secondary to a traumatic reinjury within the first year postoperatively. Despite the lack of difference in failure rates, at final follow-up, patients who undergo suture anchor repair may report significantly greater subjective function and final IKDC, KOOS Pain, Quality of Life, and Sport scores. LEVEL OF EVIDENCE: III, retrospective cohort study.


Asunto(s)
Anclas para Sutura , Traumatismos de los Tendones , Humanos , Estudios Retrospectivos , Calidad de Vida , Traumatismos de los Tendones/cirugía , Técnicas de Sutura , Medición de Resultados Informados por el Paciente , Tendones/cirugía
4.
Ann Surg Oncol ; 29(11): 7081-7091, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35904659

RESUMEN

BACKGROUND: Although internal hemipelvectomies with sacroiliac resections are not traditionally reconstructed, surgeons are increasingly pursuing pelvic ring reconstruction to theoretically improve stability, function, and early ambulation. This study aims to systematically compare complications and functional and oncologic outcomes of sacroiliac resection with and without reconstruction. METHODS: PubMed and MEDLINE were queried for studies published between January 1990 and October 2020 pertaining to sacroiliac neoplasm resection with subsequent reconstruction. Patient demographics, histopathologic diagnoses, reconstruction techniques, Musculoskeletal Tumor Society (MSTS) functional scores, and oncologic outcomes were pooled. RESULTS: Twenty-three studies (201 patients) were included for analysis. Reconstruction was performed in 79.1% of patients, most commonly with nonvascularized autografts (45.8%). The overall complication rate was 54.8%; however, resection followed by reconstruction demonstrated significantly higher complication (62.3% versus 25.7%, p < 0.001) and infection rates (13.7% versus 0%, p = 0.020). Mean MSTS functional score trended higher in nonreconstructed patients (82% versus 71.6%). CONCLUSIONS: Reconstruction after sacroiliac resection produced higher complication rates and poorer physical recovery when compared with nonreconstructed resection. This systematic review suggests that patients without spinopelvic junction instability may experience superior outcomes without reconstruction. Ultimately, the need to reconstruct the pelvic girdle depends on tumor size, prognosis, and functional goals.


Asunto(s)
Neoplasias Óseas , Hemipelvectomía , Neoplasias Óseas/patología , Neoplasias Óseas/cirugía , Humanos , Osteotomía , Estudios Retrospectivos , Resultado del Tratamiento
5.
Arthroscopy ; 38(12): 3194-3206, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35660519

RESUMEN

PURPOSE: To systematically review the associations between mental health and preoperative or postoperative outcomes of hip arthroscopy for femoroacetabular impingement. METHODS: The literature search was conducted using the PubMed, EMBASE and PsychINFO databases following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyses) guidelines. RESULTS: Nine studies were identified that met the inclusion and exclusion criteria. All studies assessing patient-reported outcomes found significantly lower patient-reported outcomes (modified Harris Hip Score, Hip Outcome Score-Activities of Daily Living, Hip Outcome Score-Sports-Specific Subscale, and International Hip Outcome Tool scores) related to worse mental health functioning before surgery. Specifically, preoperative Hip Outcome Score-Activities of Daily Living and Hip Outcome Score-Sports-Specific Subscale were significantly greater in control patients than patients in the mental health group by 11.6 points (mean difference; 95% confidence interval 7.58-15.79, P < .001) and 10 points (95% confidence interval 5.14-14.87, P < .001), without significant heterogeneity between studies (I2 = 28.59, P = .25; I2 = 0, P = .93), respectively. Patients with lower mental health status also had lower rates of achieving a minimal clinically important difference in 5 studies included in this review. CONCLUSIONS: This systematic review finds consistent evidence supporting the association between negative psychological function and worse preoperative and postoperative outcomes for patients with hip disorders. Understanding both the effect of mental health on surgical outcomes and the potential benefits of psychological intervention may represent an opportunity to improve patient outcomes following hip arthroscopy. LEVEL OF EVIDENCE: IV, systematic review of Level II-IV studies.


Asunto(s)
Artroscopía , Pinzamiento Femoroacetabular , Humanos , Articulación de la Cadera/cirugía , Actividades Cotidianas , Resultado del Tratamiento , Pinzamiento Femoroacetabular/cirugía , Medición de Resultados Informados por el Paciente , Estudios de Seguimiento , Estudios Retrospectivos
6.
Arthroscopy ; 38(8): 2493-2503, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35157963

RESUMEN

PURPOSE: To (1) determine the effect of severe patella alta on lateral patellar displacement after medial patellofemoral ligament (MPFL) reconstruction and medial quadriceps tendon-femoral ligament (MQTFL) reconstruction and (2) determine whether lateral displacement significantly differs between MPFL and MQTFL reconstructions in the setting of severe patella alta (Caton-Deschamps Index [CDI] of 1.6). METHODS: Eight cadaveric specimens were included. High-tensile strength suture was used to create a model of adjustable patellar height. Patellar height was set using fluoroscopy to CDI ratios of 1.0 (normal) and 1.6 (alta). Specimens underwent testing (1) with MPFL reconstruction, (2) with MQTFL reconstruction, and (3) in a medial patellofemoral complex (MPFC)-deficient control state, in randomized order, at both CDI settings: 1.0 and 1.6. Lateral patellar translation was measured at 0°, 10°, 20°, 30°, 45°, 60°, and 90° of knee flexion with 10 N of laterally directed load. RESULTS: At a CDI of 1.6, MPFL reconstruction showed significantly lower lateral displacement than MQTFL reconstruction at 0° and 20°. When compared with MPFC-deficient controls at a CDI of 1.6, MPFL reconstruction showed significantly lower displacement at 0° and 20° whereas MQTFL reconstruction was not significantly different at any degree of flexion. CONCLUSIONS: In the setting of severe patella alta (CDI of 1.6), MPFL reconstruction results in less lateral patellar displacement than MQTFL reconstruction at 0° and 20° of knee flexion. At higher flexion angles (≥30°), there is no difference between the 2 reconstruction techniques and the CDI no longer has an effect. At a CDI of 1.0, MPFL reconstruction shows lower displacement than MQTFL reconstruction in full extension only. Surgeons performing MPFC reconstruction should evaluate patients for patella alta and consider patellar height when deciding on the reconstruction technique. CLINICAL RELEVANCE: This study suggests that MQTFL reconstruction may be less stable than MPFL reconstruction in the setting of patella alta, without other known pathoanatomic factors, at early knee flexion angles. Patellar height should be considered when choosing the appropriate reconstruction technique in the absence of a distalization procedure.


Asunto(s)
Luxación de la Rótula , Articulación Patelofemoral , Humanos , Articulación de la Rodilla/cirugía , Ligamentos Articulares/cirugía , Rótula/cirugía , Luxación de la Rótula/cirugía , Articulación Patelofemoral/cirugía , Rango del Movimiento Articular
7.
J Shoulder Elbow Surg ; 31(4): 832-838, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34582992

RESUMEN

BACKGROUND: Electrocautery is a common surgical technique and is often used during shoulder arthroplasty to elevate or transect the subscapularis tendon. The relative amount of tissue damage caused by cautery as opposed to sharp transection is not currently known. The purpose of this study was to examine local tissue damage resulting from electrocautery vs. sharp transection with a scalpel. We hypothesized that the electrosurgical unit would cause higher collateral tissue damage and cell death compared with sharp transection. METHODS: Twelve cadaveric ovine shoulders were randomized to either the electrosurgical or sharp transection group. The infraspinatus tendon was isolated, and a partial-thickness transection was made using either a monopolar electrosurgical device (Bovie) or No. 10 scalpel blade. Tendon explants were then visualized with confocal microscopy to evaluate tissue architecture. A live/dead assay was performed using microscopy imaging analysis software. Comparisons between Bovie and scalpel transection were made using the Mann-Whitney U test, and the cell death percentage at standardized distances from the transection site was compared between groups using a mixed-model analysis. Significance was defined at P < .05. RESULTS: The cellular and tendon fibril architecture was well maintained beyond the scalpel transection site, whereas Bovie transection disrupted the architecture beyond its transection path. The percentage of dead cells in the Bovie group (74.9% ± 31.2%) was significantly higher than that in the scalpel group (27.6% ± 29.9%, P = .0004). Compared with the transection site, the cell death percentage after Bovie transection significantly declined at 2.5 mm whereas that after scalpel transection significantly declined at 1 mm from the transection site. CONCLUSION: There was a significantly higher dead cell percentage in the Bovie transection group, indicating extensive damage beyond the local incision site, compared with sharp transection. Electrosurgical transection of the ovine infraspinatus tendon ex vivo caused higher cell death and greater tissue architecture disruption compared with sharp scalpel transection.


Asunto(s)
Lesiones del Manguito de los Rotadores , Traumatismos de los Tendones , Animales , Electrocirugia/métodos , Humanos , Manguito de los Rotadores , Ovinos , Instrumentos Quirúrgicos , Traumatismos de los Tendones/cirugía
8.
J Arthroplasty ; 37(5): 917-924, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35032605

RESUMEN

BACKGROUND: Proximal femoral replacement (PFR) is reserved as a salvage procedure after failed total hip arthroplasty (THA) or after wide margin resection of tumors involving the proximal femur. Although failure of the PFR construct remains a significant problem, indication has not previously been investigated as a risk factor for failure. METHODS: This study retrospectively evaluated patients who underwent PFR over a consecutive 15-year period for primary sarcoma or metastatic disease of the proximal femur, compared with conversion to PFR after failed THA. PFR failure was defined as recurrent prosthetic dislocations, periprosthetic fracture, aseptic loosening, or infection that ultimately resulted in revision surgery. RESULTS: Overall, 99 patients were evaluated, including 58 in the neoplasm and 41 in the failed THA cohorts. Failed THA patients were older (P < .001), with a greater proportion having comorbid hypertension (P = .008), cardiac disease (P = .014), and history of prior ipsilateral and intracapsular surgeries (P < .001). The failure rate was significantly higher in failed THA patients (39.0% vs 10.3%; P < .001) with significantly shorter implant survivorship on Kaplan-Meier analysis (P = .003). A multivariate Cox proportional hazards model showed that THA failure was the only independent predictor for PFR failure (hazard ratio: 4.26, 95% confidence interval: 1.66-10.94; P = .003). CONCLUSION: This study revealed significantly worse PFR implant survivorship in patients undergoing PFR for the indication of failed THA compared with neoplasm. Although the underlying etiology of this relationship remains to be explicitly outlined, poor bone quality and soft tissue integrity, multiple prior surgeries, and comorbid conditions are likely contributing factors.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
9.
Arthroscopy ; 36(12): 3008-3009, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33276888

RESUMEN

Meniscus repairs for vertical, peripheral tears can be troublesome due to poor tissue quality and/or vascularity that can lead to re-rupture and subsequent removal. The gold standard, inside-out repair technique, has been challenged by all-inside devices for the benefit of improved efficiency and less morbidity but for the sake of expense and potential structural inferiority. Successful meniscus repair requires multiple components, only one of which is deciding the repair construct of choice. I feel the most important aspect will always be the indication based on tear configuration while respecting biology, because all fixation will eventually fail if the meniscus does not ultimately heal. While all-inside devices may have biomechanical properties that are similar to inside-out techniques, the burden of proof still lies on showing superiority of these devices in a clinical setting. Clinically, I still use inside-out repair techniques for large tears or for high-demand patients due to its structural integrity and small penetration of the meniscus.


Asunto(s)
Traumatismos de la Rodilla , Lesiones de Menisco Tibial , Fenómenos Biomecánicos , Humanos , Traumatismos de la Rodilla/cirugía , Meniscos Tibiales/cirugía , Técnicas de Sutura , Lesiones de Menisco Tibial/cirugía
10.
Clin Orthop Relat Res ; 477(11): 2443-2451, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31389875

RESUMEN

BACKGROUND: Electronic health records (EHRs) have become ubiquitous in orthopaedics. Although they offer certain benefits, they have been cited as a factor that can contribute to provider burnout. Little is known about the degree to which EHR adoption is associated with provider and practice characteristics or outpatient and surgical volume. QUESTIONS/PURPOSES: (1) What was the rate of EHR adoption in orthopaedics and how are physician and practice characteristics associated with adoption? (2) How is EHR adoption related to outpatient productivity? (3) How is EHR adoption associated with surgical volume? METHODS: We conducted this retrospective analysis by linking three publicly available Medicare databases, which we chose for their reliability in reporting because they are provided by a government-funded entity. We included providers in the 2016 Physician Compare dataset who reported a primary specialty of orthopaedic surgery. The EHR adoption status for these providers between 2011 and 2016 was determined using the Meaningful Use Eligible Professional public use files, which we chose to standardize both adoption and usage of EHRs. Provider characteristics, from the Physician Compare dataset, were compared between non-adopters, early adopters (who adopted EHR in 2011 and 2012), and late adopters (2016) using a multivariate logistic analysis, due to the binary nature of the dependent variable (adoption). To measure productivity and billing, we used the 2012 and 2016 Medicare Utilization and Payment datasets. To measure productivity before and after EHR adoption, we compared the number of services for select Current Procedural Terminology codes between 2012 and 2016 for providers who first adopted EHR in 2013, and performed the same comparison for non-adopters for the same years. Paired t-tests were used where volume in 2012 and 2016 were being compared, and multivariate analysis was performed. RESULTS: By 2016, 10,904 of 21,484 orthopaedic providers (51%) had adopted EHRs, with an increase from 8% to 46% during the incentive phase (2011 to 2014) and an increase from 44% to 51% during the penalty phase (2015 to 2016). After analyzing factors associated with adoption, it was most notable that for every additional year since graduation, the odds of adopting EHR later increased by 4.14 (95% confidence interval 4.00 to 4.33; p < 0.001). After adoption, providers who adopted EHRs increased the mean number of Medicare outpatient visits per year from 439 to 470 (mean difference, increase of 31 procedures [95% CI 24 to 39]; p < 0.001), and providers who did not use EHRs decreased from 378 to 368 visits per year (median difference, decrease of 10 procedures [95% CI 8.0 to 12.0]; p < 0.001). EHR was not associated with billing for Level 4-5 visits, after adjusting for practice size and pre-adoption volumes (p = 0.32; R = 0.51). EHR adoption was not associated with surgical volume for 10 of 11 common orthopaedic procedures. However, two additional TKA procedures annually could be attributed to EHR adoption, when compared with non-adopters (p = 0.03; R = 0.65). After adoption, orthopaedic surgeons increased their annual TKA volume from 42 to 48 (mean difference, increase of 6 [95% CI 4.0 to 7.0]; p < 0.001), while non-adopting orthopaedic surgeons increased their annual surgical volume for TKA from 28 to 30 (median difference, increase of 2 [95% CI 2.0 to 4.0]; p < 0.001). CONCLUSIONS: In orthopaedics, the Health Information Technology for Economic and Clinical Health (HITECH) Act resulted in approximately half of self-reported orthopaedic surgeons adopting EHR from 2011 to 2016. Considering the high cost of most EHRs and the substantial investment in adoption incentives, this adoption rate may not be sufficient to fully realize the objectives of the HITECH Act. Diffusion of technology is a vast field of study within social theory. Prominent sociologist Everett M. Rogers details its complexity in Diffusion of Innovations. Diffusion of technology is impacted by factors such as the possibility to sample the innovation without commitment, opinion leadership, and observability of results in a peer network, to name a few. Incorporating these principles, where appropriate, into a more focused action plan may facilitate technological diffusion for future innovations. Lastly, EHR adoption was not associated with higher-level billing or surgical volume. This might suggest that EHRs have not had a meaningful clinical benefit, but this needs to be further investigated by relating these trends to patient outcomes or other quality measures. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Eficiencia Organizacional , Registros Electrónicos de Salud , Procedimientos Ortopédicos/estadística & datos numéricos , Ortopedia , Administración de la Práctica Médica/organización & administración , Humanos , Modelos Logísticos , Estudios Retrospectivos
11.
Orthop J Sports Med ; 12(6): 23259671241241537, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38855071

RESUMEN

Background: While the biomechanical properties of the native medial patellofemoral ligament (MPFL) have been well studied, there is no comprehensive summary of the biomechanics of MPFL reconstruction (MPFLR). An accurate understanding of the kinematic properties and functional behavior of current techniques used in MPFLR is imperative to restoring native biomechanics and improving outcomes. Purpose: To provide a comprehensive review of the biomechanical effects of variations in MPFLR, specifically to determine the effect of graft choice and reconstruction technique. Study Design: Systematic review. Methods: A systematic review was performed in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. A total of 32 studies met inclusion criteria: (1) using ≥8 human cadaveric specimens, (2) reporting on a component of MPFLR, and (3) having multiple comparison groups. Results: Gracilis, semitendinosus, and quadriceps grafts demonstrated an ultimate load to failure (N) of 206.2, 102.8, and 190.0 to 205.0 and stiffness (N/mm) of 20.4, 8.5, and 21.4 to 33.6, respectively. Single-bundle and double-bundle techniques produced an ultimate load to failure (N) of 171 and 213 and stiffness (N/mm) of 13.9 and 17.1, respectively. Anchors placed centrally and superomedially in the patella produced the smallest degree of length changes throughout range of motion in contrast to anchors placed more proximally. Sutures, suture anchors, and transosseous tunnels all produced similar ultimate load to failure, stiffness, and elongation data. Femoral tunnel malpositioning resulted in significant increases in contact pressures, patellar translation, tilt, and graft tightening or loosening. Low tension grafts (2 N) most closely restored the patellofemoral contact pressures, translation, and tilt. Graft fixation angles variably and inconsistently altered contact pressures, and patellar translation and tilt. Conclusion: Data demonstrated that placement of the MPFLR femoral tunnel at the Schöttle point is critical to success. Femoral tunnel diameter should be ≥2 mm greater than graft diameter to limit graft advancement and overtensioning. Graft fixation, regardless of graft choice or fixation angle, is optimally performed under minimal tension with patellar fixation at the medial and superomedial patella. However, lower fixation angles may reduce graft strain, and higher fixation angles may exacerbate anisometry and length changes if femoral tunnel placement is nonanatomic.

12.
Am J Sports Med ; 52(5): 1374-1383, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38251854

RESUMEN

BACKGROUND: Approximately 90% of patients who undergo arthroscopic rotator cuff repair (RCR) are satisfied with their pain levels and function after surgery. However, a subset of patients experience continued symptoms that warrant revision surgery. Preoperative risk factors for RCR failure requiring revision surgery have not been clearly defined. PURPOSE: To (1) determine the rate of RCR failure requiring revision surgery and (2) identify risk factors for revision surgery, which will help surgeons to determine patients who are at the greatest risk for RCR failure. STUDY DESIGN: Systematic review and meta-analysis; Level of evidence, 4. METHODS: A systematic review and meta-analysis in accordance with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were performed. The initial search resulted in 3158 titles, and 533 full-text articles were assessed for eligibility. A total of 10 studies met the following inclusion criteria: (1) human clinical studies, (2) arthroscopic RCR, (3) original clinical research, and (4) evaluation of preoperative risk factors for revision. RESULTS: After a full-text review, a total of 16 risk factors were recorded and analyzed across 10 studies. Corticosteroid injection was the most consistent risk factor for revision surgery, reaching statistical significance in 4 of 4 studies, followed by workers' compensation status (2/3 studies). Patients with corticosteroid injections had a pooled increased risk of revision surgery by 47% (odds ratio, 1.44 [95% CI, 1.36-1.52]). Patients with workers' compensation had a pooled increased risk of revision surgery by 133% (odds ratio, 2.33 [95% CI, 2.09-2.60]). Age, smoking status, diabetes, and obesity were found to be risk factors in half of the analyzed studies. CONCLUSION: Corticosteroid injections, regardless of the frequency of injections, and workers' compensation status were found to be significant risk factors across the literature based on qualitative analysis and pooled analysis. Surgeons should determine ideal candidates for arthroscopic RCR by accounting for corticosteroid injection history, regardless of the frequency, and insurance status of the patient.


Asunto(s)
Artroscopía , Reoperación , Lesiones del Manguito de los Rotadores , Humanos , Factores de Riesgo , Reoperación/estadística & datos numéricos , Lesiones del Manguito de los Rotadores/cirugía , Manguito de los Rotadores/cirugía , Corticoesteroides/uso terapéutico
13.
Am J Sports Med ; 52(7): 1753-1764, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38761016

RESUMEN

BACKGROUND: The indirect head of the rectus femoris (IHRF) tendon has been used as an autograft for segmental labral reconstruction. However, the biomechanical properties and anatomic characteristics of the IHRF, as they relate to surgical applications, have yet to be investigated. PURPOSE: To (1) quantitatively and qualitatively describe the anatomy of IHRF and its relationship with surrounding arthroscopically relevant landmarks; (2) detail radiographic findings pertinent to IHRF; (3) biomechanically assess segmental labral reconstruction with IHRF, including restoration of the suction seal and contact pressures in comparison with iliotibial band (ITB) reconstruction; and (4) assess potential donor-site morbidity caused by graft harvesting. STUDY DESIGN: Descriptive laboratory study. METHODS: A cadaveric study was performed using 8 fresh-frozen human cadaveric full pelvises and 7 hemipelvises. Three-dimensional anatomic measurements were collected using a 3-dimensional coordinate digitizer. Radiographic analysis was accomplished by securing radiopaque markers of different sizes to the evaluated anatomic structures of the assigned hip.Suction seal and contact pressure testing were performed over 3 trials on 6 pelvises under 4 different testing conditions for each specimen: intact, labral tear, segmental labral reconstruction with ITB, and segmental labral reconstruction with IHRF. After IHRF tendon harvest, each full pelvis had both the intact and contralateral hip tested under tension along its anatomic direction to assess potential site morbidity, such as tendon failure or bony avulsion. RESULTS: The centroid and posterior apex of the indirect rectus femoris attachment are respectively located 10.3 ± 2.6 mm and 21.0 ± 6.5 mm posteriorly, 2.5 ± 7.8 mm and 0.7 ± 8.0 mm superiorly, and 5.0 ± 2.8 mm and 22.2 ± 4.4 mm laterally to the 12:30 labral position. Radiographically, the mean distance of the IHRF to the following landmarks was determined as follows: anterior inferior iliac spine (8.8 ± 2.5 mm), direct head of the rectus femoris (8.0 ± 3.9 mm), 12-o'clock labral position (14.1 ± 2.8 mm), and 3-o'clock labral position (36.5 ± 4.4 mm). During suction seal testing, both the ITB and the IHRF reconstruction groups had significantly lower peak loads and lower energy to peak loads compared with both intact and tear groups (P = .01 to .02 for all comparisons). There were no significant differences between the reconstruction groups for peak loads, energy, and displacement at peak load. In 60° of flexion, there were no differences in normalized contact pressure and contact area between ITB or IHRF reconstruction groups (P > .99). There were no significant differences between intact and harvested specimen groups in donor-site morbidity testing. CONCLUSION: The IHRF tendon is within close anatomic proximity to arthroscopic acetabular landmarks. In the cadaveric model, harvesting of the IHRF tendon as an autograft does not lead to significant donor-site morbidity in the remaining tendon. Segmental labral reconstruction performed with the IHRF tendon exhibits similar biomechanical outcomes compared with that performed with ITB. CLINICAL RELEVANCE: This study demonstrates the viability of segmental labral reconstruction with an IHRF tendon and provides a detailed anatomic description of the tendon in the context of an arthroscopic labral reconstruction. Clinicians can use this information during the selection of a graft and as a guide during an arthroscopic graft harvest.


Asunto(s)
Cadáver , Tendones , Humanos , Fenómenos Biomecánicos , Tendones/trasplante , Articulación de la Cadera/cirugía , Articulación de la Cadera/diagnóstico por imagen , Masculino , Músculo Cuádriceps/diagnóstico por imagen , Femenino , Persona de Mediana Edad , Anciano , Radiografía
14.
J Am Acad Orthop Surg ; 31(24): 1205-1210, 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-37816190

RESUMEN

Rotator cuff repair (RCR) augmentation is often considered for patients with large-to-massive rotator cuff tears or chronic tears with poor tissue quality. Augmentation can provide mechanical stability and improved biology to improve the likelihood of a successful repair. This article discusses the indications, diagnosis, surgical techniques, and outcomes for RCR augmentation using an acellular dermal allograft, partially demineralized cancellous allograft, dermal xenograft, bone marrow aspirate concentrate, and platelet-rich plasma.


Asunto(s)
Plasma Rico en Plaquetas , Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Humanos , Artroplastia , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/cirugía
15.
Global Spine J ; 13(7): 1803-1811, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34736350

RESUMEN

STUDY DESIGN: Basic Science. OBJECTIVE: Poor subchondral bone mineral density (sBMD) has been linked with subsidence of cervical interbody devices or grafts, which are traditionally placed centrally on the endplates. Considering that sBMD reflects long-term stress distributions, we hypothesize that the cervical uncovertebral joints are denser than the central endplate region. This study sought to investigate density distributions using computed tomography osteoabsorptiometry (CT-OAM). METHODS: Twelve human cervical spines from C3-C7 (60 vertebrae, 120 endplates) were imaged with CT and segmented to create 3D reconstructions. The superior and inferior endplates were isolated, and the sBMD of the whole endplate, endplate center, and uncus was evaluated using CT-OAM. Density distributions were compared across the subaxial cervical spine. RESULTS: The uncinate region of the inferior and superior endplates was significantly denser than the central endplate across all vertebral levels (P < .01). When comparing sBMD of the whole inferior and superior endplates, the superior endplate was significantly denser than the inferior endplate (P < .0001). However, the inferior uncus was denser than the superior uncus (P = .035). When assessing sBMD by vertebral level, peak densities were observed at C4 and C5, while C7 was, on average, significantly less dense than all other vertebrae. CONCLUSION: The subchondral bone of the cervical uncovertebral joints is significantly denser than the central endplates. While the superior endplate in its entirety is denser than the inferior endplate, the inverse was true for the uncovertebral joints. This study serves as a basis for future investigations of new implant designs and their implications on subsidence.

16.
Global Spine J ; 13(5): 1342-1349, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34263668

RESUMEN

STUDY DESIGN: Retrospective cohort study. OBJECTIVES: The current evidence regarding how level of lumbar pedicle subtraction osteotomy (PSO) influences correction of sagittal alignment is limited. This study sought to investigate the relationship of lumbar level and segmental angular change (SAC) of PSO with the magnitude of global sagittal alignment correction. METHODS: This study retrospectively evaluated 53 consecutive patients with adult spinal deformity who underwent lumbar PSO at a single institution. Radiographs were evaluated to quantify the effect of PSO on lumbar lordosis (LL), thoracic kyphosis (TK), sacral slope (SS), pelvic tilt (PT), pelvic incidence (PI), T1-spinopelvic inclination (T1SPI), T1-pelvic alignment (TPA), and sagittal vertical axis (SVA). RESULTS: Significant correlations were found between PSO SAC and the postoperative increase in LL (r = 0.316, P = .021) and PT (r = 0.352, P = .010), and a decrease in TPA (r = -0.324, P = .018). PSO level significantly correlated with change in T1SPI (r = -0.305, P = .026) and SVA (r = -0.406, P = .002), with more caudal PSO corresponding to a greater correction in sagittal balance. On multivariate analysis, more caudal PSO level independently predicted a greater reduction in T1SPI (ß = -3.138, P = .009) and SVA (ß = -29.030, P = .001), while larger PSO SAC (ß = -0.375, P = .045) and a greater number of fusion levels (ß = -1.427, P = .036) predicted a greater reduction in TPA. CONCLUSION: This study identified a gain of approximately 3 degrees and 3 cm of correction for each level of PSO more caudal to L1. Additionally, a larger PSO SAC predicted greater improvement in TPA. While further investigation of these relationships is warranted, these findings may help guide preoperative PSO level selection.

17.
Am J Sports Med ; 51(1): 25-31, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36412555

RESUMEN

BACKGROUND: Tibial tubercle-trochlear groove (TT-TG) distance is a risk factor for recurrent patellar dislocation and is often included in algorithmic treatment of instability. The underlying factors that determine TT-TG have yet to be clearly described in orthopaedic literature. PURPOSE/HYPOTHESIS: The purpose of our study was to determine the underlying anatomic factors contributing to TT-TG distance. We hypothesized that degree of tubercle lateralization and knee rotation angle may substantially predict TT-TG. STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: All patients evaluated for patellar instability at a single institution between 2013 and 2021 were included. Patients with previous knee osseous procedures were excluded. TT-TG and its anatomic relationship to patellofemoral measures, including dysplasia, femoral anteversion, tibial tubercle lateralization, knee rotation angle, and tibial torsion, were measured and subsequently quantified using univariate and multivariable analysis. RESULTS: In total, 76 patients met the inclusion criteria (46 female, 30 male; mean ± SD age, 20.6 ± 8.6 years) and were evaluated. Mean TT-TG was 16.2 ± 5.4 mm. On univariate analysis, increasing knee rotation angle (P < .01), tibial tubercle lateralization (P = .02), and tibial torsion (P = .01) were associated with increased TT-TG. In dysplastic cases, patients without medial hypoplasia (Dejour A or B) demonstrated significantly increased TT-TG (18.1 ± 5.4 mm) as compared with those with medial hypoplasia (Dejour C or D; TT-TG: 14.9 ± 5.2 mm; P = .02). Multivariable analysis revealed that increased knee rotation angle (+0.43-mm TT-TG per degree; P < .01) and tubercle lateralization (+0.19-mm TT-TG per percentage lateralization; P < .01) were statistically significant determinants of increased TT-TG distance. Upon accounting for these factors, tibial torsion, trochlear width, and medial hypoplasia were no longer significant components in predicting TT-TG (P≥ .54). Of note, all patients with TT-TG ≥20 mm had tibial tubercle lateralization ≥68%, a knee rotation angle ≥5.8°, or both factors concurrently. CONCLUSION: TT-TG distance is most influenced by knee rotation angle and tibial tubercle lateralization.


Asunto(s)
Inestabilidad de la Articulación , Luxación de la Rótula , Articulación Patelofemoral , Humanos , Masculino , Femenino , Niño , Adolescente , Adulto Joven , Adulto , Luxación de la Rótula/diagnóstico por imagen , Articulación Patelofemoral/diagnóstico por imagen , Inestabilidad de la Articulación/diagnóstico por imagen , Estudios Transversales , Tibia/diagnóstico por imagen , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos
18.
Arthrosc Sports Med Rehabil ; 5(3): e559-e567, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37388861

RESUMEN

Purpose: To describe the capacity for concentration of a single processing machine for bone marrow aspirate concentrate (BMAC) production and investigate the effects of demographic factors on the number of mesenchymal stromal cells (MSCs) in BMAC. Methods: Patients enrolled in our institution's randomized control trials involving BMAC who had complete BMAC flow cytometry data were included. Multipotent MSC phenotype, defined as cell-surface coexpression of specific-identifying antigens (≥95% positive) and the absence of hematopoietic lineage markers (≤2% positive), was determined for both patient bone marrow aspirate (BMA) and BMAC samples. The ratio of cells in BMA:BMAC samples was calculated and Spearman correlations (i.e., body mass index [BMI]) and Kruskall-Wallis (i.e., age: <40, 40-60, >60 years) or Mann-Whitney (i.e., sex) tests were used to determine the relationship of cell concentration to demographic factors. Results: Eighty patients were included in analysis (49% male, mean age: 49.9 ± 12.2 years). Mean concentration of BMA and BMAC was 2,048.13 ± 2,004.14 MSCs/mL and 5,618.87 ± 7,568.54 MSC/mL, respectively, with a mean BMAC:BMA ratio of 4.35 ± 2.09. A significantly greater MSC concentration was observed in the BMAC samples when compared with BMA (P = .005). No patient demographic factors (age, sex, height, weight, BMI) were found to predict MSC concentration in the BMAC samples (P ≥ .01). Conclusions: Demographic factors, including age, sex, and BMI do not impact the final concentration of MSCs in BMAC when using a single harvest technique (anterior iliac crest) and a single processing system. Clinical Relevance: As the role of BMAC therapy expands in clinical application, it becomes increasingly important to understand the determinants of BMAC composition and how it is affected by different harvesting techniques, concentrating processes, and patient demographics.

19.
Arthrosc Tech ; 11(4): e483-e489, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35493049

RESUMEN

Rotator cuff repair in the setting of a chronic tear or poor tissue quality presents a surgical challenge because of the high risk of structural failure. Patients with an increased risk of retear may be candidates for enthesis augmentation with a novel, biphasic allograft, composed of a demineralized cancellous matrix with a layer of mineralized bone. This interpositional graft was designed with the intention to promote both soft-tissue and osseous integration into the matrix, thereby conferring greater stability and regeneration of the transitional zone of the rotator cuff enthesis. Here, we describe a technique for a transosseous-equivalent supraspinatus repair with placement of a biphasic interpositional allograft.

20.
Curr Rev Musculoskelet Med ; 15(2): 82-89, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35469362

RESUMEN

PURPOSE OF REVIEW: Patellofemoral instability involves complex, three-dimensional pathological anatomy. However, current clinical evaluation and diagnosis relies on attempting to capture the pathology through numerous two-dimensional measurements. This current review focuses on recent advancements in patellofemoral imaging and three-dimensional modeling. RECENT FINDINGS: Several studies have demonstrated the utility of dynamic imaging modalities. Specifically, radiographic patellar tracking correlates with symptomatic instability, and quadriceps activation and weightbearing alter patellar kinematics. Further advancements include the study of three-dimensional models. Automation of commonly utilized measurements such as tibial tubercle-trochlear groove (TT-TG) distance has the potential to resolve issues with inter-rater reliability and fluctuation with knee flexion or tibial rotation. Future directions include development of robust computational models (e.g., finite element analysis) capable of incorporating patient-specific data for surgical planning purposes. While several studies have utilized novel dynamic imaging and modeling techniques to enhance our understanding of patellofemoral joint mechanics, these methods have yet to find a definitive clinical utility. Further investigation is required to develop practical implementation into clinical workflow.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA