RESUMEN
BACKGROUND/PURPOSE: Frameless stereotactic radiosurgery (SRS) requires dedicated systems to monitor patient motion in order to avoid inaccurate radiation delivery due to involuntary shifts. The purpose of this study is to assess the accuracy and sensitivity of two distinct motion monitoring systems used for frameless SRS. METHODS: A surface image-guided system known as optical surface monitoring system (OSMS), and a fiducial marker-based system known as high definition motion management (HDMM) as part of the latest Gamma Knife Icon® were compared. A 3D printer-based cranial motion phantom was developed to evaluate the accuracy and sensitivity of these two systems in terms of: (1) the capability to recognize predefined shifts up to 3â¯cm, and (2) the capability to recognize predefined speeds up to 3â¯cm/s. The performance of OSMS, in terms of different reference surfaces, was also evaluated. RESULTS: Translational motion could be accurately detected by both systems, with an accuracy of 0.3â¯mm for displacement up to 1â¯cm, and 0.5â¯mm for larger displacements. The reference surface selection had an impact on OSMS performance, with flat surface resulting in less accuracy. HDMM was in general more sensitive when compared with OSMS in capturing the motion, due to its faster frame rate, but a delay in response was observed with faster speeds. Both systems were less sensitive in detection of superior-inferior motion when compared to lateral or vertical displacement directions. CONCLUSION: Translational motion can be accurately and sensitively detected by OSMS and HDMM real-time monitoring systems. However, performance variations were observed along different motion directions, as well as amongst the selection of reference images. Caution is needed when using real-time monitoring systems for frameless SRS treatment.
Asunto(s)
Neoplasias Encefálicas/radioterapia , Radiocirugia/instrumentación , Neoplasias Encefálicas/cirugía , Diseño de Equipo , Humanos , Movimiento (Física) , Posicionamiento del Paciente/instrumentación , Posicionamiento del Paciente/métodos , Fantasmas de Imagen , Impresión Tridimensional/instrumentación , Radiocirugia/métodosRESUMEN
INTRODUCTION: Deep brain stimulation (DBS) hardware complications have been traditionally managed by removal of the entire system. Explantation of the system results in prolonged interruption to the patient's care and potential challenges when considering reimplantation of the cranial leads. The purpose of this study was to understand whether complete explantation can be avoided for patients initially presenting with wound dehiscence and/or infection of hardware. METHODS: We performed a retrospective study that included 30 cases of wound dehiscence or infection involving the DBS system. Patients underwent reoperation without explantation of the DBS system, with partial explanation, or with complete explantation as initial management of the complication. RESULTS: A total of 17/30 cases were managed with hardware-sparing wound revisions. The majority presented with wound dehiscence (94%), with the scalp (n = 9) as the most common location. This was successful in 76.5% of patients (n = 13). Over 11/30 patients were managed with partial explantation. The complication was located at the generator (91%) or at the scalp (9%). Partial explantation was successful in 64% of patients (n = 7). In cases that underwent a lead-sparing approach, 33% of patients ultimately required removal of the intracranial lead, and 2/30 cases of hardware infection were managed initially with total explantation. DISCUSSION/CONCLUSION: Wound dehiscence can be successfully managed without complete removal of the DBS system in most cases. In cases of infection, removing the involved component(s) and sparing the intracranial leads may be considered. Wound revision without removal of the entire DBS system is safe and can improve quality of life by preventing or shortening the withdrawal of DBS treatment.
Asunto(s)
Estimulación Encefálica Profunda , Estimulación Encefálica Profunda/efectos adversos , Electrodos Implantados/efectos adversos , Humanos , Complicaciones Posoperatorias/etiología , Calidad de Vida , Reoperación , Estudios RetrospectivosRESUMEN
PURPOSE: Magnetic resonance-guided laser interstitial thermal therapy (LITT) has been increasingly used to treat a number of intracranial pathologies, though its use in the posterior fossa has been limited to a few small series. We performed a multi-institutional review of targets in the posterior fossa, reporting the efficacy and safety profile associated with laser ablation in this region of the brain. METHODS: A retrospective review of patients undergoing LITT in the posterior fossa was performed from August 2010 to March 2020. Patient demographic information was collected alongside the operative parameters and patient outcomes. Reported outcomes included local control of the lesion, postoperative complications, hospital length of stay, and steroid requirements. RESULTS: 58 patients across four institutions underwent LITT in the posterior fossa for 60 tumors. The median pre-ablation tumor volume was 2.24 cm3. 48 patients (50 tumors) were available for follow-up. An 84% (42/50) overall local control rate was achieved at 9.5 months median follow up. There were two procedural complications, including insertional hemorrhage and laser misplacement and 12/58 (21%) patients developed new neurological deficits. There was one procedure related death. The median length of hospital stay was 1 day, with 20.7% of patients requiring discharge to a rehabilitation facility. CONCLUSIONS: LITT is an effective approach for treating pathology in the posterior fossa. The average target size is smaller than what has been reported in the supratentorial space. Care must be taken to prevent injury to surrounding structures given the close proximity of critical structures in this region.
Asunto(s)
Hipertermia Inducida/métodos , Neoplasias Infratentoriales/cirugía , Terapia por Láser/métodos , Imagen por Resonancia Magnética/métodos , Cirugía Asistida por Computador/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Adulto JovenRESUMEN
OBJECTIVE: There is a paucity of studies assessing the use of MR-guided laser interstitial thermal therapy (LITT), specifically in the elderly population. The aim of this study was to evaluate the safety of LITT for brain tumors in geriatric patients. METHODS: Geriatric patients (≥ 65 years of age) treated with LITT for intracranial tumors at a single institution between January 2011 and November 2019 were retrospectively identified. The authors grouped patients into two distinct age cohorts: 65-74 years (group 1) and 75 years or older (group 2). Baseline characteristics, operative parameters, postoperative course, and morbidity were recorded for each patient. RESULTS: Fifty-five geriatric patients underwent 64 distinct LITT procedures for brain tumors. The majority of lesions (40 [62.5%]) treated were recurrent brain metastases or radiation necrosis. The median modified frailty index was 0.1 (low frailty; range 0-0.4) for patients in group 1 and 0.2 (intermediate frailty; range 0-0.4) for patients in group 2 (p > 0.05). The median hospital length of stay (LOS) was 1 day (IQR 1-2 days); there was no significant difference in LOS between the age groups. The hospital stay was significantly longer in patients who presented with a neurological symptom and in those who experienced a postoperative complication. The majority of patients (43 [68.3%] of 63 cases) were fit for discharge to their preoperative accommodation following LITT. The rate of discharge to home was not significantly different between the age groups. Those discharged to rehabilitation facilities were more likely to have presented with a neurological symptom. Nine patients (14.1% of cases) were found to have acute neurological complications following LITT, with nearly all patients showing complete or partial recovery at follow-up. The 30-day postoperative mortality rate was 1.6% (1 case). The complication and 30-day postoperative mortality rates were not significantly different between the two age groups. CONCLUSIONS: LITT can be considered a minimally invasive and safe neurosurgical procedure for the treatment of intracranial tumors in geriatric patients. Careful preoperative preparation and postoperative care is essential as LITT is not without risk. Appropriate patient selection for cranial surgery is essential, because neurosurgeons are treating an increasing number of elderly patients, but advanced age alone should not exclude patients from LITT without considering frailty and comorbidities.
Asunto(s)
Neoplasias Encefálicas , Terapia por Láser , Anciano , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Humanos , Rayos Láser , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
PURPOSE: Magnetic resonance-guided laser-induced thermal therapy (MRgLITT) is a minimally invasive procedure used to treat various intracranial pathologies. This study investigated the effects of variable power on maximal estimated thermal damage during ablation and duration required to reach maximal ablation. MATERIALS/METHODS: All ablations were performed using the Visualase Thermal Therapy System (Medtronic Inc., Minneapolis, Minnesota), which uses a 980 nm diffusing tip diode laser. Cases were stratified into low, medium and high power. Maximal thermal damage estimate (TDEmax) achieved in a single plane and time to reach maximal damage (ttdemax) were measured and compared between groups using a 2×3 Fixed Factor Analysis of Covariance. Ablation area change for cases in which an initial thermal dose was followed by a subsequent dose, with increased power, was also assessed. RESULTS: We used real-time ablation data from 93 patients across various intracranial pathologies. ttdemax (mean ± SEM) decreased linearly as power increased (low: 139.2 ± 10.4 s, medium: 127.5 ± 4.3 s, high: 103.7 ± 5.8 s). In cases where a second thermal dose was delivered at higher power, the TDE expanded an average of 51.4 mm2 beyond the initial TDE generated by the first ablation, with the second ablation approaching TDEmax at a higher rate than the initial ablation. CONCLUSION: Increased power results in a larger TDEmax and an increased ablation rate. In cases where an initial thermal dose does not fully ablate the target lesion, a second ablation at higher power can increase the area of ablation with an increased ablation rate.
Asunto(s)
Terapia por Láser/métodos , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto JovenRESUMEN
Polymorphous low-grade neuroepithelial tumor of the young (PLNTY) is a recently described variant of low-grade neuroepithelial tumors that exhibits infiltrative growth, histopathological variability with frequently prominent oligodendroglioma-like components, intense labeling for CD34, absence of 1P/19Q codeletion, a distinct DNA methylation signature and genetic alterations involving MAP kinase pathway constituents of either the B-Raf proto-oncogene BRAF or fibroblast growth factor receptors 2 or 3 (FGFR2 and FGFR3). We here report a newly diagnosed case of PLNTY involving the temporal lobe in a 31-year-old man with chronic focal epilepsy. This tumor had histologic and immunophenotypic features similar to the recently described PLNTY and proved BRAF V600E mutant. Biomolecular profiling is becoming increasingly important in characterizing neuroepithelial tumors. Furthermore, biomolecular features such as CD34 expression and BRAF mutation have been reported to be significantly associated with the clinical behavior of these tumors. Like other low-grade neuroepithelial tumors, PLNTYs appear to be generally indolent with excellent seizure relief after total surgical resection. It is important to recognize cases of PLNTY in order to guide clinical management including the indication for surgery.â©.
Asunto(s)
Astrocitoma/genética , Glioma/genética , Neoplasias Neuroepiteliales/genética , Oligodendroglioma/genética , Adulto , Astrocitoma/patología , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/patología , Glioma/diagnóstico , Humanos , Masculino , Mutación/genética , Neoplasias Neuroepiteliales/patología , Oligodendroglioma/patología , Proto-Oncogenes Mas , Proteínas Proto-Oncogénicas B-raf/genéticaRESUMEN
BACKGROUND AND OBJECTIVES: Magnetic-Resonance Guided Laser-Induced Thermal Therapy (MRgLITT) is a minimally-invasive ablation procedure for treating intracranial pathology using laser energy delivered through a fiber-optic. Saline irrigation is used to cool the fiber-optic, but factors affecting irrigation efficacy are not well studied, and quantitative information regarding irrigation speed and volume during MRgLITT procedures have not been reported. Here, we aimed to characterize variables affecting irrigation efficacy in MRgLITT. METHODS: We investigated the irrigation setup of the Visualase thermal therapy system during MRgLITT procedures (Visualase Inc., Houston, TX). Using the system's peristaltic pump, irrigation flow rate was quantitated by measuring volume over five one-minute intervals. Pump settings 1-10 were assessed with and without the position-locking, resistance-imparting bone anchor in both single and double-catheter setups. Multiple tightness settings of the bone anchor were tested, and flow rates were analyzed. RESULTS: Rate of flow increased non-linearly with pump setting (F(1,4) = 2168.86; P < 0.001) in both single and double catheter setups. The lowest pump setting had a flow rate of 24 cc/min, while the highest setting was 36 cc/min. The rate of change in flow successively decreased without plateau. Tightness setting of the bone anchor affected flow in a reverse sigmoid pattern, with no impact on rate until after two quarter-turns, which produced a marked decrease in flow up to one-half of the initial rate (F(1,4) = 12818.96; P < 0.001). CONCLUSION: Flow rate through the cooling catheter in MRgLITT follows a non-linear pattern with increasing peristaltic pump speed. This rate is subject to significant changes when the bone anchor is tightened more than two quarter-turns. These findings serve as a foundation for future studies aimed at understanding the effect of irrigation speeds in achieving optimal ablation volumes.
Asunto(s)
Técnicas de Ablación/métodos , Terapia por Láser/métodos , Imagen por Resonancia Magnética , Cirugía Asistida por Computador , Irrigación Terapéutica/métodosRESUMEN
OBJECTIVE: Coding for neurosurgical procedures is a complex process that is dynamically changing year to year, through the annual introduction and removal of codes and modifiers. The authors hoped to elucidate if publicly available artificial intelligence (AI) could offer solutions for neurosurgeons with regard to coding. METHODS: Multiple publicly available AI platforms were asked to provide Current Procedural Terminology (CPT) codes and Revenue Value Units (RVU) values for common neurosurgical procedures of the brain and spine with a given indication for the procedure. The responses of platforms were recorded and compared to the currently valid CPT codes used for the procedure and the amount of RVUs that would be gained. RESULTS: Six platforms and Google were asked for the appropriate CPT codes for 10 endovascular, spinal, and cranial procedures each. The highest performing platforms were as follows: Perplexity.AI identified 70% of endovascular, BingAI identified 55% of spinal, and ChatGPT 4.0 with Bing identified 75% of cranial CPT codes. With regard to RVUs, the top performer gained 78% of endovascular, 42% of spinal, and 70% of cranial possible RVUs. With regard to accuracy, AI platforms on average outperformed Google (45% vs. 25%, P = 0.04236). CONCLUSIONS: The ability of publicly available AIs to successfully code for neurosurgical procedures holds great promise in the future. Future development of AI should focus on improving accuracy with regard to CPT codes and providing supporting documentation for its decisions. Improvement on the existing capabilities of AI platforms can allow for increased operational efficiency and cost savings for practices.
Asunto(s)
Current Procedural Terminology , Neurocirugia , Humanos , Inteligencia Artificial , Procedimientos Neuroquirúrgicos , Columna Vertebral/cirugíaRESUMEN
BACKGROUND: MR-guided Laser Induced Thermal Therapy (LITT) is a procedure for intracranial tumors. Minimal data exists regarding post-procedure lesion volume changes. OBJECTIVES: We aim to analyze changes in lesion volume during the post-LITT period using polygonal tracing with fusion. Additionally, we investigated the role of lesion histopathology on LITT parameters and volume dynamics. METHODS: Sixteen patients with intracranial neoplasms received LITT. Using OsiriX DICOM Viewer, three raters computed lesion volumes at the following: pre-ablation (PreA), immediate post-ablation (IPA), 24 hours post-ablation (24PA), and first follow-up post-ablation (FPA), which ranged from 4 to 11 weeks post-ablation. Statistical analyses for volume changes between time points and inter-rater reliability were performed. Additionally, comparisons were made between metastatic versus non-metastatic and small versus large lesions in terms of operative parameters and volume changes. RESULTS: There was an acute increase in volume at IPA with a decrease in size by 24PA. ANOVA among inter-rater datasets showed no significant difference at any time point (highest F(1,15) = 0.225, P > 0.80, for IPA). GLM repeated measures, for Intra-Rater analysis, demonstrated statistically significant differences across time points (lowest F(1,15) = 13.297, P = 0.003). IPA volumes were larger than those at PreA, 24PA, and FPA (average volume increase [95% CI]: 281% [157-404%], 167% [134-201%], 187% [154-219%], respectively; all P < 0.004). Correlation analysis showed lower inter-rater reliability at IPA versus other time points (all P < 0.03). Larger lesions (>2.5 cm³ ) versus smaller (<2.5 cm³ ) did not demonstrate a difference in percent volume increase. Operative parameters and volume dynamics were not different between metastatic and non-metastatic groups. CONCLUSIONS: The response of intracranial lesions to LITT demonstrates a peak in volume at the IPA time point with decreased IPA inter-rater reliability. We recommend that conclusions about intracranial lesion size post-LITT be made at least 24 hours post-LITT rather than immediately after LITT.
Asunto(s)
Neoplasias Encefálicas/cirugía , Terapia por Láser/métodos , Láseres de Semiconductores/uso terapéutico , Imagen por Resonancia Magnética Intervencional , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias Encefálicas/patología , Niño , Femenino , Estudios de Seguimiento , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Retrospectivos , Resultado del Tratamiento , Carga Tumoral , Adulto JovenRESUMEN
Laser-induced thermal therapy (LITT) has evolved over the past two decades to treat a number of intracranial pathologies. Although it initially emerged as a salvage treatment of surgically inoperable tumors or recurrent lesions that had exhausted more conventional treatments, it is now being used as a primary, first-line treatment in certain instances with outcomes comparable to traditional surgical resection. The authors discuss the evolution of LITT in the treatment of gliomas and future directions, which may further enhance the efficacy of this procedure.
Asunto(s)
Neoplasias Encefálicas , Glioma , Terapia por Láser , Humanos , Neoplasias Encefálicas/cirugía , Terapia por Láser/métodos , Glioma/cirugía , Rayos LáserRESUMEN
PURPOSE: To understand if unexplained signal artifacts in MRg-LITT proton resonance frequency- (PRF-) shift thermometry images are caused by air bubbles or hemorrhages, and to characterize their effects on temperature measurements. METHODS: Retrospective image data from an IRB-approved clinical trial of intracranial MRg-LITT were inspected for asymmetric distortions observed in phase data during ablations, which have been previously reported as likely hemorrhages. A total of eight patient cases were selected: seven with artifact occurrence and one without. Mathematical image models for air bubbles or hemorrhages were implemented to estimate the size of the air bubble or hemorrhage needed to explain the clinically observed phase artifacts. Correlations and Bland-Altman analyses were used to determine if an air bubble model or a hemorrhage model was better correlated to the clinical data. The model was used to inject bubbles into clean PRF phase data without artifacts to examine how temperature profile distortions change with slice orientation. The simulated air-bubble injected data were compared to clinical data containing artifacts to examine the bubbles' effects on temperature and thermal damage estimates. RESULTS: The model demonstrated that air bubbles up to approximately 1 cm in diameter could explain the clinically observed phase artifacts. The bubble model predicts that a hemorrhage would have to be 2.2 times as large as an air bubble in order to explain the same extent of phase distortion observed in clinical data. Air bubbles had 16% percent higher correlations to the clinical PRF phase data than hemorrhages, even after rescaling the hemorrhage phases to better match the data. The air bubble model also explains how the phase artifacts lead to both large positive and large negative temperature errors, up to ±100 °C, which could cascade to damage estimate errors of several millimeters. CONCLUSION: Results showed that the artifacts are likely caused by air bubbles rather than hemorrhages, which may be introduced before heating or appear during heating. Manufacturers and users of devices that rely upon PRF-shift thermometry should be aware these phase distortions from bubble artifacts can result in large temperature errors.
Asunto(s)
Artefactos , Imagen por Resonancia Magnética , Humanos , Rayos Láser , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Estudios Retrospectivos , TemperaturaRESUMEN
BACKGROUND/AIMS: Microelectrode recording (MER) is necessary for precision localization of target structures such as the subthalamic nucleus during deep brain stimulation (DBS) surgery. Attempts to automate this process have produced quantitative temporal trends (feature activity vs. time) extracted from mobile MER data. Our goal was to evaluate computational methods of generating spatial profiles (feature activity vs. depth) from temporal trends that would decouple automated MER localization from the clinical procedure and enhance functional localization in DBS surgery. METHODS: We evaluated two methods of interpolation (standard vs. kernel) that generated spatial profiles from temporal trends. We compared interpolated spatial profiles to true spatial profiles that were calculated with depth windows, using correlation coefficient analysis. RESULTS: Excellent approximation of true spatial profiles is achieved by interpolation. Kernel-interpolated spatial profiles produced superior correlation coefficient values at optimal kernel widths (r = 0.932-0.940) compared to standard interpolation (r = 0.891). The choice of kernel function and kernel width resulted in trade-offs in smoothing and resolution. CONCLUSIONS: Interpolation of feature activity to create spatial profiles from temporal trends is accurate and can standardize and facilitate MER functional localization of subcortical structures. The methods are computationally efficient, enhancing localization without imposing additional constraints on the MER clinical procedure during DBS surgery.
Asunto(s)
Estimulación Encefálica Profunda/métodos , Procesamiento de Señales Asistido por Computador , Fenómenos Electrofisiológicos , Humanos , Microelectrodos , Reproducibilidad de los Resultados , Subtálamo/fisiologíaRESUMEN
BACKGROUND: Brain shift during deep brain stimulation (DBS) surgery may compromise target localization. Loss of cerebrospinal fluid is believed to be the underlying mechanism, thus an intraventricular trajectory during DBS surgery may be associated with increased shift, in addition to other complications, such as intraventricular hemorrhage. OBJECTIVE: We set out to assess the effect of traversing the lateral ventricle on brain shift during DBS surgery. METHODS: We performed a retrospective review of 65 pre- and postoperative MR images of patients who underwent bilateral subthalamic nucleus deep brain stimulator placement to treat advanced Parkinson's disease. Patients were separated into two groups: Group A (intraventricular trajectory, n = 46) and Group B (no intraventricular trajectory, n = 19). In these patients, we compared pre- and postoperative frame coordinates of the red nucleus (RN). RESULTS: Group B demonstrated significantly more posterior shift of the center of the RN (1.40 ± 1.32 mm) than Group A (0.64 ± 1.76 mm; p < 0.02). We found no increase in incidence of intraventricular hemorrhage or the number of microelectrode trajectory attempts. CONCLUSIONS: Intraventricular trajectories during DBS surgery do not appear to compromise safety or targeting accuracy.
Asunto(s)
Estimulación Encefálica Profunda/efectos adversos , Estimulación Encefálica Profunda/métodos , Enfermedad de Parkinson/terapia , Anciano , Femenino , Humanos , Incidencia , Hemorragias Intracraneales/epidemiología , Hemorragias Intracraneales/etiología , Imagen por Resonancia Magnética , Masculino , Microelectrodos , Persona de Mediana Edad , Enfermedad de Parkinson/patología , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
BACKGROUND: Magnetic resonance-guided laser interstitial thermal therapy (MRgLITT) uses intraoperative temperature mapping and thermal damage estimates to guide ablations of intracranial targets. In select cases, signal artifact presents at the target site and impairs intraprocedural decision-making by obscuring the visualization of both temperature imaging and the thermal damage estimate calculation. To date, the etiology and impact of signal artifact are unknown. However, user-selected MRgLITT software settings may play a role in generating artifact. OBJECTIVE: To assess the effect of the thresholding feature in MRgLITT software on signal artifact generation during intracranial ablations. METHODS: Ablations were performed with the Visualase MRI-guided Laser Ablation System (Medtronic). For each LITT procedure, raw thermal data were extracted at a reference threshold of 40 and reprocessed at 5 additional threshold values ranging from 35 to 60. Artifact growth rates relative to threshold values were derived using simple linear regressions and then assessed within the context of laser power and duration using Pearson correlations. RESULTS: A total of 33 patients were included, with 28 artifact-containing and 5 artifact-free cases. For artifact-containing cases, a 13% increase in artifact area occurred for every 1-point increase in threshold (R2 > 0.99). Artifact growth rates were not correlated with laser power (r = 0.15, P = .44) or duration (r = 0.0049, P = .98). One of the 5 artifact-free cases developed artifact at a threshold of 60. CONCLUSION: Artifact generation is likely multifactorial involving tissue properties and software settings. Operators can minimize software-introduced artifact by reducing threshold values.
Asunto(s)
Artefactos , Terapia por Láser , Humanos , Terapia por Láser/métodos , Rayos Láser , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Programas InformáticosRESUMEN
OBJECTIVE: Magnetic resonance-guided laser interstitial thermal therapy (MRgLITT) is a minimally invasive and effective treatment option that can potentially treat deep-seated pathologies in cases without safe open surgical corridors. In the present report, we have described our experience using MRgLITT for brainstem pathologies. METHODS: A retrospective medical record review and analysis were conducted for all patients who had undergone MRgLITT for pathologies within or closely surrounding the brainstem between 2011 and 2020. The patients had undergone stereotactic laser placement in the operating suite and were transported to the magnetic resonance imaging suite for laser ablation with real-time monitoring. The demographics, operative parameters, and complications were recorded. RESULTS: A total of 12 patients had undergone MRgLITT for brainstem pathologies. The average age of the patients was 47.6 years (range, 4-75 years). The pathologies included both primary and metastatic intracranial tumors. The average preablation volume of the targets was 2.4 ± 0.50 cm3. The average ablation time was 324.3 ± 60.7 seconds, and the average postablation volume was 2.92 ± 0.53 cm3. One perioperative mortality was directly related to the procedure and 7 patients developed postoperative deficits. Two patients had experienced a recurrence after MRgLITT and opted to undergo additional alternative treatment. CONCLUSIONS: The brainstem represents formidable territory even for minimally invasive procedures. The overall morbidity and mortality has remained high, and the probability of achieving a meaningful outcome must be carefully assessed.
Asunto(s)
Terapia por Láser , Imagen por Resonancia Magnética , Adolescente , Adulto , Anciano , Tronco Encefálico/diagnóstico por imagen , Tronco Encefálico/cirugía , Niño , Preescolar , Humanos , Terapia por Láser/métodos , Rayos Láser , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto JovenRESUMEN
BACKGROUND: Robotic-assisted stereotactic systems for deep brain stimulation (DBS) have recently gained popularity because of their abilities to automate arduous human error-prone steps for lead implantation. Recent DBS literature focuses on frame-based robotic platforms, but little has been reported on frameless robotic approaches, specifically the Food and Drug Administration-approved Mazor Renaissance Guidance System (Mazor Robotics Ltd). OBJECTIVE: To present an initial case series for patients undergoing awake DBS with the Mazor Renaissance Guidance System and evaluate operative variables and stereotactic accuracy. METHODS: Retrospective data collection at a single institution was conducted for an initial 35 consecutive patients. Patient demographics and operative variables, including case times, microelectrode recording passes, and postoperative complications, were obtained by chart review. Implant accuracy was evaluated through measuring radial and vector (x, y) errors using the Mazor software. Pneumocephalus volumes were calculated using immediate postoperative T1-weighted MRI scans. RESULTS: Total operating room (245 ± 5.5 min) and procedural (179 ± 4.7) times were comparable with previous awake DBS literature. The radial error for center tract implants was 1.3 ± 0.1 mm, with smaller error in the first (1.1 ± 0.2) vs second (1.7 ± 0.3) implants of bilateral DBS (P = .048). Vector error analysis demonstrated larger shifts posteriorly for first implants and medially for second implants. Pneumocephalus volumes (12.4 ± 2.2 cm3) were not associated with increased microelectrode recording passes, radial error, or complications. CONCLUSION: Frameless robotic-assisted DBS is a safe and efficient new technology that has been easily adopted into the workflow at our institution.
Asunto(s)
Estimulación Encefálica Profunda , Neumocéfalo , Humanos , Imagenología Tridimensional , Microelectrodos , Estudios Retrospectivos , Estados UnidosRESUMEN
AIMS: The impact of decompressive hemicraniectomy (DCH) on the overall outcome of pediatric brain injury patients has not been fully determined. In this paper, the authors performed a systematic review of patient outcome based on quality of life following DCH in a pediatric population. METHODS: We describe our experience with decompressive craniectomy in pediatric patients and perform a literature review and pooled outcomes analysis to supplement these findings. A total of 13 children underwent DCH for intractable intracranial pressure in our institution from 2000 to 2008. Follow-up was available in 11 patients with 1 death (9%) and 7 survivors (70%) obtaining a favorable outcome (Glasgow Outcome Scale, GOS, scores = 4-5). RESULTS: A literature review to determine the usefulness of DCH identified 17 articles that, when combined with our series, resulted in 186 pediatric DCH cases. Pooled outcomes found 42 deaths and 112 patients who had favorable outcomes at 6 months. The average 6-month mortality was 21.1%, and the pooled mean quality of life among survivors 0.75 (0.68-0.82), midway between moderate disability and good outcome. CONCLUSIONS: Based on our findings, DCH results in a majority of pediatric patients having a good outcome based on the GOS score.
Asunto(s)
Lesiones Encefálicas/cirugía , Craneotomía/tendencias , Descompresión Quirúrgica/tendencias , Calidad de Vida , Lesiones Encefálicas/mortalidad , Lesiones Encefálicas/psicología , Niño , Humanos , Calidad de Vida/psicología , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND AND PURPOSE: Magnetic resonance-guided laser interstitial thermal therapy (MRgLITT) is a minimally invasive procedure that produces real-time thermal damage estimates (TDEs) of ablation. Currently, MRgLITT software provides limited quantitative parameters for intraoperative monitoring, but orthogonal TDE-MRI slices can be utilized to mathematically estimate ablation volume. The objective of this study was to model TDE volumes and validate using post-24 hours MRI ablative volumes. METHODS: Ablations were performed with the Visualase Laser Ablation System (Medtronic). Using ellipsoidal parameters determined for dual-TDEs from orthogonal MRI planes, TDE volumes were calculated by two definite integral methods (A and B) implemented in Matlab (MathWorks). Post-24 hours MRI ablative volumes were measured in OsiriX (Pixmeo) by two-blinded raters and compared to TDE volumes via paired t-test and Pearson's correlations. RESULTS: Twenty-two ablations for 20 patients with various intracranial pathologies were included. Average TDE volume calculated with method A was 3.44 ± 1.96 cm3 and with method B was 4.83 ± 1.53 cm3 . Method A TDE volumes were significantly different than post-24 hours volumes (P < .001). Method B TDE volumes were not significantly different than post-24 hours volumes (P = .39) and strongly correlated with each other (r = .85, R2 = .72, P < .0001). A total of eight of 22 (36%) method A versus 17 of 22 (77%) method B TDE volumes were within 25% of the post-24 hours ablative volume. CONCLUSION: We present a viable mathematical method integrating dual-plane TDEs to calculate volumes. Future algorithmic iterations will incorporate additional calculated variables that improve ablative volume estimations.
Asunto(s)
Terapia por Láser/efectos adversos , Imagen por Resonancia Magnética , Modelos Biológicos , Cirugía Asistida por Computador/efectos adversos , Adulto , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/cirugía , Humanos , Rayos Láser , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio , Programas InformáticosRESUMEN
OBJECTIVE: Laser interstitial thermal therapy (LITT) provides a minimally invasive alternative to open brain surgery, making it a powerful neurosurgical tool especially in pediatric patients. This systematic review aimed to highlight the indications and complications of LITT in the pediatric population. METHODS: In line with the PRISMA guidelines, the authors conducted a systematic review to summarize the current applications and safety profiles of LITT in pediatrics. PubMed and Embase were searched for studies that reported the outcomes of LITT in patients < 21 years of age. Retrospective studies, case series, and case reports were included. Two authors independently screened the articles by title and abstract followed by full text. Relevant variables were extracted from studies that met final eligibility, and results were pooled using descriptive statistics. RESULTS: The selection process captured 303 pediatric LITT procedures across 35 studies. Males comprised approximately 60% of the aggregate sample, with a mean age of 10.5 years (range 0.5-21 years). The LITT technologies used included Visualase (89%), NeuroBlate (9%), and Multilase 2100 (2%). The most common indication was treatment of seizures (86%), followed by brain tumors (16%). The mean follow-up duration was 15.6 months (range 1.3-48 months). The overall complication rate was 15.8%, which comprised transient neurological deficits, cognitive and electrolyte disturbances, hemorrhage, edema, and hydrocephalus. No deaths were reported. CONCLUSIONS: As of now, LITT's most common applications in pediatrics are focused on treating medically refractory epilepsy and brain tumors that can be difficult to resect. The safety of LITT can provide an attractive alternative to open brain surgery in the pediatric population.
RESUMEN
Brain metastasis (BM) affects up to one-third of adults with cancer and carries a historically bleak prognosis. Despite advances in stereotactic radiosurgery (SRS), rates of in-field recurrence (IFR) after SRS range from 10 to 25%. High rates of neurologic death have been reported after SRS failure, particularly for recurrences deep in the brain and surgically inaccessible. Laser interstitial thermal therapy (LITT) is an emerging option in this setting, but its ability to prevent a neurologic death is unknown. In this study, we investigate the causes of death among patients with BM who undergo LITT for IFR after SRS. We conducted a single institution retrospective case series of patients with BM who underwent LITT for IFR after SRS. Clinical and demographic data were collected via chart review. The primary endpoint was cause of death. Between 2010 and 2018, 70 patients with BM underwent LITT for IFR after SRS. Median follow-up after LITT was 12.0 months. At analysis, 49 patients died; a cause was determined in 44. Death was neurologic in 20 patients and non-neurologic in 24. The 24-month cumulative incidence of neurologic and non-neurologic death was 35.1% and 38.6%, respectively. Etiologies of neurologic death included local recurrence (n = 7), recovery failure (n = 7), distant progression (n = 5), and other (n = 1). Among our patient population, LITT provided the ability to stabilize neurologic disease in up to 2/3 of patients. For IFR after SRS, LITT may represent a reasonable treatment strategy for select patients. Additional work is necessary to determine the extent to which LITT can prevent neurologic death after recurrence of BM.