Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 215
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38725220

RESUMEN

INTRODUCTION: We performed a cross-sectional study using the Centers for Disease Control and Prevention's (CDC's) Wide-Ranging Online Data for Epidemiologic Research (WONDER) database to analyze the trends in cardiac implantable electronic device (CIED) infection-related mortality from 1999 to 2020. METHODS: We analyzed the death certificate data from the CDC WONDER database from 1999 to 2020 for CIED infections in the US population aged ≥25 years using International Classification of Diseases, Tenth Revision (ICD-10) codes, listed as the underlying or contributing cause of death. Age-adjusted mortality rates (AAMR) and 95% confidence intervals (CIs) were computed per 1 million population by standardizing crude mortality rates to the 2000 US census population. To assess annual mortality trends, we employed the Joinpoint regression model, calculating the annual percent change (APC) in AAMR and corresponding 95% CIs. RESULTS: Overall, there was an observed declining trend in AAMRs related to CIED infection-related mortality. Males accounted for 55% of the total deaths, with persistently higher AAMRs compared to females over the study duration. Both males and females had an overall decreasing trend in AAMRs throughout the study duration. On race/ethnicity stratified analysis, non-Hispanic (NH) Blacks exhibited the highest overall AAMR, followed by NH American Indians or Alaska Natives, NH Whites, Hispanic or Latinos, and NH Asian or Pacific Islanders. On a stratified analysis based on region, the South region had the highest overall AAMR, followed by the Midwest, West, and Northeast regions. CONCLUSION: Our study demonstrates a significant decline in CIED infection-related mortality in patients over the last two decades. Notable gender, racial/ethnic, and regional differences exist in the rates of mortality related to CIED infections.

2.
J Cardiovasc Electrophysiol ; 35(6): 1196-1202, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38590268

RESUMEN

INTRODUCTION: Ventricular tachycardia storm or electrical storm (ES) is a common complication following left ventricular assist device (LVAD) implantation. The factors contributing to ES and outcomes are less studied. The study aimed to determine the factors associated with ES and the probability of survival in patients undergoing LVAD in three tertiary centers over a span of 15 years. METHODS: We performed a retrospective cohort study on all patients who underwent LVAD implantation at the Mayo Clinic (Rochester, Phoenix, and Jacksonville) from January 1, 2006 to December 31, 2020. ES was defined as ≥3 episodes of sustained ventricular tachycardia over a period of 24 h with no identifiable reversible cause. Detailed chart reviews of the electronic health records within the Mayo Clinic and outside medical records were performed. RESULTS: A total of 883 patients who underwent LVAD implantation were included in our study. ES occurred in 7% (n = 61) of patients with a median of 13 days (interquartile range [IQR]: 5-297 days) following surgery. We found 57% of patients (n = 35) developed ES within 30 days, while 43% (n = 26) patients developed ES at a median of 545  (IQR 152-1032) days after surgery. Following ES, 26% of patients died within 1 year. Patients with ES had a significant association with a history of ventricular arrhythmias and implantable cardioverter defibrillator (ICD) shocks before the procedure. ES was significantly associated with reduced survival compared to patients without ES (hazards ratio [HR]: 1.92, 95% CI: 1.39-2.64, p < .001). CONCLUSION: Following LVAD implantation, the rate of ES was 7% with majority of ES occurring within 30 days of LVAD. Risk factors for ES included pre-implant history of ventricular arrhythmias and ICD shock. ES was significantly associated with reduced survival compared to patients without ES.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Implantación de Prótesis , Taquicardia Ventricular , Función Ventricular Izquierda , Humanos , Femenino , Estudios Retrospectivos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Factores de Tiempo , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/etiología , Resultado del Tratamiento , Anciano , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Implantación de Prótesis/mortalidad , Medición de Riesgo , Potenciales de Acción , Frecuencia Cardíaca , Adulto
3.
BMC Cardiovasc Disord ; 24(1): 131, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38424483

RESUMEN

This umbrella review synthesizes data from 17 meta-analyses investigating the comparative outcomes of catheter ablation (CA) and medical treatment (MT) for atrial fibrillation (AF). Outcomes assessed were mortality, risk of hospitalization, AF recurrence, cardiovascular events, pulmonary vein stenosis, major bleeding, and changes in left ventricular ejection fraction (LVEF) and MLHFQ score. The findings indicate that CA significantly reduces overall mortality and cardiovascular hospitalization with high strength of evidence. The risk of AF recurrence was notably lower with CA, with moderate strength of evidence. Two associations reported an increased risk of pulmonary vein stenosis and major bleeding with CA, supported by high strength of evidence. Improved LVEF and a positive change in MLHFQ were also associated with CA. Among patients with AF and heart failure, CA appears superior to MT for reducing mortality, improving LVEF, and reducing cardiovascular rehospitalizations. In nonspecific populations, CA reduced mortality and improved LVEF but had higher complication rates. Our findings suggest that CA might offer significant benefits in managing AF, particularly in patients with heart failure. However, the risk of complications, including pulmonary vein stenosis and major bleeding, is notable. Further research in understudied populations may help refine these conclusions.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Estenosis de Vena Pulmonar , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Ablación por Catéter/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hemorragia/inducido químicamente , Ensayos Clínicos Controlados Aleatorios como Asunto , Estenosis de Vena Pulmonar/etiología , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Metaanálisis como Asunto
4.
J Cardiovasc Electrophysiol ; 34(5): 1196-1205, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37130436

RESUMEN

INTRODUCTION: Most patients undergoing a left atrial appendage occlusion (LAAO) procedure are admitted for overnight observation. A same-day discharge strategy offers the opportunity to improve resource utilization without compromising patient safety. We compared the patient safety outcomes and post-discharge complications between same-day discharge versus hospital admission (HA) (>1 day) in patients undergoing LAAO procedure. METHODS: A systematic search of MEDLINE and Embase was conducted. Outcomes of interest included peri-procedural complications, re-admissions, discharge complications including major bleeding and vascular complications, ischemic stroke, all-cause mortality, and peri-device leak >5 mm. Mantel-Haenszel risk ratios (RRs) with 95% CIs were calculated. RESULTS: A total of seven observational studies met the inclusion criteria. There was no statistically significant difference between same-day discharge versus HA regarding readmission (RR: 0.61; 95% confidence interval [CI]: [0.29-1.31]; p = .21), ischemic stroke after discharge (RR: 1.16; 95% CI: [0.49-2.73]), peri-device leak >5 mm (RR: 1.27; 95% CI: [0.42-3.85], and all-cause mortality (RR: 0.60; 95% CI: [0.36-1.02]). The same-day discharge study group had significantly lower major bleeding or vascular complications (RR: 0.71; 95% CI: [0.54-0.94]). CONCLUSIONS: This meta-analysis of seven observational studies showed no significant difference in patient safety outcomes and post-discharge complications between same-day discharge versus HA. These findings provide a solid basis to perform a randomized control trial to eliminate any potential confounders.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Apéndice Atrial/cirugía , Alta del Paciente , Cuidados Posteriores , Resultado del Tratamiento , Estudios Observacionales como Asunto
5.
J Cardiovasc Electrophysiol ; 34(12): 2514-2526, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37787013

RESUMEN

BACKGROUND: Obesity is associated with an increased risk of developing recurrent atrial fibrillation (AF) after catheter ablation (CA). However, the current data on weight loss interventions show inconsistent results in preventing the recurrence of AF after CA. METHODS: We conducted a systematic search in MEDLINE and EMBASE to identify studies that reported the outcome of recurrence of AF after CA in obese patients undergoing weight interventions. The subgroup analysis included: (1) Weight loss versus no weight loss, (2) >10% weight loss versus <10% weight loss, (3) <10% weight loss versus no weight loss, (4) Follow-up <12 months, and (5) Follow-up >12 months after CA. Mantel-Haenszel risk ratios with a 95% confidence interval (CI) were calculated using a random effects model and for heterogeneity, I2 statistics were reported. RESULTS: A total of 10 studies (one randomized controlled trial and nine observational studies) comprising 1851 patients were included. The recurrence of AF was numerically reduced in the weight loss group (34.5%) versus no weight loss group (58.2%), but no statistically significant difference was observed (risk ratio [RR] = 0.76; 95% CI: 0.49-1.18, p = .22). However, there was a statistically significant reduction in recurrence of AF with weight loss versus no weight loss at follow-up >12 months after CA (RR = 0.47; 95% CI: 0.32-0.68, p < .0001). At follow-up >12 months after CA, both >10% weight loss versus <10% weight loss (RR = 0.49; 95% CI: 0.31-0.80, p = .004) and <10% weight loss versus no weight loss (RR = 0.39; 95% CI: 0.31-0.49, p < .00001) were associated with a statistically significant reduction in recurrent AF. CONCLUSION: In patients with AF undergoing CA, weight loss is associated with reducing recurrent AF at > 12 months after ablation and these benefits are consistently seen with both >10% and <10% weight loss. The benefits of weight loss in preventing recurrent AF after CA should be examined in larger studies with extended follow-up duration.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Resultado del Tratamiento , Recurrencia , Obesidad/complicaciones , Obesidad/diagnóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto
6.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37595138

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). There is limited data regarding the outcomes of AF catheter ablation in HCM patients. In this study, we aimed to synthesize all available evidence on the effectiveness of ablation of AF in patients with HCM compared to those without HCM. METHODS AND RESULTS: We systematically reviewed bibliographic databases to identify studies published through February 2023. We included cohort studies with available quantitative information on rates of recurrent atrial arrhythmias, anti-arrhythmic drug (AAD) therapy, and repeat ablation procedures after initial AF ablation in patients with vs without HCM. Estimates were combined using random-effects meta-analysis models and reported as risk ratios (RR) and 95% confidence intervals (CI). Eight studies were included in quantitative synthesis (262 HCM and 642 non-HCM patients). During median follow-up 13-54 months across studies, AF recurrence rates ranged from 13.3% to 92.9% in HCM and 7.6% to 58.8% in non-HCM patients. The pooled RR for recurrent atrial arrhythmia after the first AF ablation in HCM patients compared to non-HCM controls was 1.498 (95% CI = 1.305-1.720; P < 0.001). During follow-up, HCM patients more often required AAD therapy (RR = 2.844; 95% CI = 1.713-4.856; P < 0.001) and repeat AF ablation (RR = 1.544; 95% CI = 1.070-2.228; P = 0.02). The pooled RR for recurrent atrial arrhythmias after the last AF ablation was higher in patients with HCM than those without HCM (RR = 1.607; 95% CI = 1.235-2.090; P < 0.001). CONCLUSIONS: Compared to non-HCM patients, those with HCM had higher rates of recurrent atrial arrhythmias, AAD use, and need for repeat AF ablation after initial ablation of AF.


Asunto(s)
Técnicas de Ablación , Fibrilación Atrial , Cardiomiopatía Hipertrófica , Fármacos Cardiovasculares , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/cirugía , Ablación por Catéter/efectos adversos
7.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37208304

RESUMEN

AIMS: Haematopoietic stem cell transplantation (HSCT) is a potentially curative therapy for several malignant and non-malignant haematologic conditions. Patients undergoing HSCT are at an increased risk of developing atrial fibrillation (AF). We hypothesized that a diagnosis of AF would be associated with poor outcomes in patients undergoing HSCT. METHODS AND RESULTS: The National Inpatient Sample (2016-19) was queried with ICD-10 codes to identify patients aged >50 years undergoing HSCT. Clinical outcomes were compared between patients with and without AF. A multivariable regression model adjusting for demographics and comorbidities was used to calculate the adjusted odds ratio (aOR) and regression coefficients with corresponding 95% confidence intervals and P-values. A total of 50 570 weighted hospitalizations for HSCT were identified, out of which 5820 (11.5%) had AF. Atrial fibrillation was found to be independently associated with higher inpatient mortality (aOR 2.75; 1.9-3.98; P < 0.001), cardiac arrest (aOR 2.86; 1.55-5.26; P = 0.001), acute kidney injury (aOR 1.89; 1.6-2.23; P < 0.001), acute heart failure exacerbation (aOR 5.01; 3.54-7.1; P < 0.001), cardiogenic shock (aOR 7.73; 3.17-18.8; P < 0.001), and acute respiratory failure (aOR 3.24; 2.56-4.1; P < 0.001) as well as higher mean length of stay (LOS) (+2.67; 1.79-3.55; P < 0.001) and cost of care (+67 529; 36 630-98 427; P < 0.001). CONCLUSION: Among patients undergoing HSCT, AF was independently associated with poor in-hospital outcomes, higher LOS, and cost of care.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Trasplante de Médula Ósea/efectos adversos , Comorbilidad , Hospitalización , Tiempo de Internación
8.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37341446

RESUMEN

BACKGROUND AND AIMS: Colchicine is an anti-inflammatory drug that may prevent post-operative atrial fibrillation (POAF). The effect of this drug has been inconsistently shown in previous clinical trials. We aimed to compare the efficacy and safety of colchicine vs. placebo to prevent POAF in patients undergoing cardiac surgery. METHODS AND RESULTS: A systematic search of EMBASE, MEDLINE, SCOPUS, ClinicalTrials.gov, and the Cochrane Library for randomized controlled trials (RCTs) was conducted from inception till April 2023. The primary outcome was the incidence of POAF after any cardiac surgery. The secondary outcome was the rate of drug discontinuation due to adverse events and adverse gastrointestinal events. Risk ratios (RR) were reported using the Mantel Haenszel method. A total of eight RCTs comprising 1885 patients were included. There was a statistically significant lower risk of developing POAF with colchicine vs. placebo (RR: 0.70; 95% CI: 0.59-0.82; P < 0.01, I2 = 0%), and this effect persisted across different subgroups. There was a significantly higher risk of adverse gastrointestinal events (RR: 2.20; 95% CI: 1.38-3.51; P < 0.01, I2 = 55%) with no difference in the risk of drug discontinuation in patients receiving colchicine vs. placebo (RR: 1.33; 95% CI: 0.93-1.89; P = 0.11, I2 = 0%). CONCLUSION: This meta-analysis of eight RCTs shows that colchicine is effective at preventing POAF, with a significantly higher risk of adverse gastrointestinal events but no difference in the rate of drug discontinuation. Future studies are required to define the optimal duration and dose of colchicine for the prevention of POAF.


Asunto(s)
Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Humanos , Colchicina/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Ensayos Clínicos Controlados Aleatorios como Asunto , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Incidencia
9.
Cardiovasc Drugs Ther ; 37(1): 151-157, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-34581901

RESUMEN

PURPOSE: To evaluate the effect of single-dose intravenous dexamethasone on atrial fibrillation (AF) recurrence following radiofrequency catheter ablation. METHODS: A cohort of 84 adult patients (> 18 years) underwent catheter ablation at Mayo Clinic Rochester from January to March 2019. Only first-time ablation patients were included, with all re-do ablations excluded to minimize heterogeneity. Administration of intraoperative dexamethasone 4 mg or 8 mg was determined by chart review from the procedure. At our institution, intraoperative intravenous steroids are administered for postoperative nausea and vomiting (PONV) prophylaxis at the discretion of the anesthesiologist. AF recurrence was determined by ECG or cardiac monitoring within 3 months or between 3 and 12 months post-ablation with an in-person follow-up visit. RESULTS: A total of 31 (36.9%) patients received intravenous dexamethasone compared to 54 (63.1%) who did not (approximating a 2:1 comparison group). The incidence of documented AF or atrial flutter, lasting greater than 30 s, within the first 3 months post-ablation was 29.0% in the dexamethasone group versus 24.5% in the non-dexamethasone group (p value 0.80). AF or atrial flutter recurrence at 3-12 months post-ablation was 3.2% in the dexamethasone group compared to 9.4% in the non-dexamethasone group (p value 0.41). CONCLUSION: These data suggest that intraoperative intravenous dexamethasone administered during AF ablation for postoperative nausea and vomiting prophylaxis may not have a significant effect on AF recurrence rates.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Adulto , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Náusea y Vómito Posoperatorios/cirugía , Ablación por Catéter/efectos adversos , Enfermedad Crónica , Esteroides
10.
BMC Cardiovasc Disord ; 23(1): 83, 2023 02 11.
Artículo en Inglés | MEDLINE | ID: mdl-36774486

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is relatively less frequent in younger patients (age < 50). Recently, studies have suggested that early restoration of sinus rhythm may lead to improved outcomes compared with rate control, however the efficacy of catheter ablation for AF in young is scarce. METHODS: We included all hospitalized patients between 18 and 50 years with a diagnosis of AF from the Nationwide Readmission Database 2016-2017 from the Healthcare Cost and Utilization Project. Demographic and comorbidity data were collected and analyzed. Outcomes assessed included one-year AF readmission rates, all-cause readmission, ischemic stroke, and all-cause mortality. Subgroup analyses were performed for all demographic and comorbidity variables. RESULTS: Overall, 52,598 patients (medium age 44, interquartile range 38-48, female 25.7%) were included in the study, including 2,146 (4.0%) who underwent catheter ablation for AF. Patients who underwent catheter ablation had a significantly lower rate of readmission for AF or any cause at one year (adjusted hazard ratios (HR) of 0.52 [95% confidence interval (CI): 0.43-0.63] and HR of 0.81 [95% CI: 0.72-0.89], respectively). There was no difference in 1-year readmission for stroke or all-cause mortality between the two groups. Subgroup analyses showed a consistent reduction in the risk of AF readmission among major demographic and comorbidity subgroups. CONCLUSION: Catheter ablation in young patients with AF was associated with a reduction in 1-year AF related and all-cause readmissions. These data merit further prospective investigation for validation, through dedicated registries and multicenter collaborations to include young AF from diverse population.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Humanos , Femenino , Adulto , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Factores de Riesgo , Comorbilidad , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Ablación por Catéter/efectos adversos
11.
Pacing Clin Electrophysiol ; 46(10): 1242-1245, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37695052

RESUMEN

The association of psychosocial risk factors with cardiovascular disease is well-established, and there is a growing recognition of their influence on atrial fibrillation (AF) . A recent National Heart, Lung, and Blood Institute workshop called for transforming AF research to integrate social determinants of health. There is limited data examining the impact of psychosocial risk factors (PSRFs) on outcomes in patients with an established diagnosis of AF. Catheter ablation for AF has been shown to improve arrhythmia burden and quality of life compared with medical treatment alone. It is unknown how PSRFs affect clinical outcomes in patients undergoing AF ablation. It is important to understand this relationship, especially given the increasing adoption of catheter ablation in clinical practice.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Calidad de Vida , Resultado del Tratamiento , Factores de Riesgo , Ablación por Catéter/efectos adversos , Recurrencia
12.
Ann Noninvasive Electrocardiol ; 28(6): e13085, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37670480

RESUMEN

The discrimination of ventricular tachycardia (VT) versus supraventricular wide complex tachycardia (SWCT) via 12-lead electrocardiogram (ECG) is crucial for achieving appropriate, high-quality, and cost-effective care in patients presenting with wide QRS complex tachycardia (WCT). Decades of rigorous research have brought forth an expanding arsenal of applicable manual algorithm methods for differentiating WCTs. However, these algorithms are limited by their heavy reliance on the ECG interpreter for their proper execution. Herein, we introduce the Mayo Clinic ventricular tachycardia calculator (MC-VTcalc) as a novel generalizable, accurate, and easy-to-use means to estimate VT probability independent of ECG interpreter competency. The MC-VTcalc, through the use of web-based and mobile device platforms, only requires the entry of computerized measurements (i.e., QRS duration, QRS axis, and T-wave axis) that are routinely displayed on standard 12-lead ECG recordings.


Asunto(s)
Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Electrocardiografía/métodos , Diagnóstico Diferencial , Taquicardia Ventricular/diagnóstico , Taquicardia Supraventricular/diagnóstico , Algoritmos
13.
Ann Noninvasive Electrocardiol ; 28(1): e13018, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36409204

RESUMEN

BACKGROUND: Accurate automated wide QRS complex tachycardia (WCT) differentiation into ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) can be accomplished using calculations derived from computerized electrocardiogram (ECG) data of paired WCT and baseline ECGs. OBJECTIVE: Develop and trial novel WCT differentiation approaches for patients with and without a corresponding baseline ECG. METHODS: We developed and trialed WCT differentiation models comprised of novel and previously described parameters derived from WCT and baseline ECG data. In Part 1, a derivation cohort was used to evaluate five different classification models: logistic regression (LR), artificial neural network (ANN), Random Forests [RF], support vector machine (SVM), and ensemble learning (EL). In Part 2, a separate validation cohort was used to prospectively evaluate the performance of two LR models using parameters generated from the WCT ECG alone (Solo Model) and paired WCT and baseline ECGs (Paired Model). RESULTS: Of the 421 patients of the derivation cohort (Part 1), a favorable area under the receiver operating characteristic curve (AUC) by all modeling subtypes: LR (0.96), ANN (0.96), RF (0.96), SVM (0.96), and EL (0.97). Of the 235 patients of the validation cohort (Part 2), the Solo Model and Paired Model achieved a favorable AUC for 103 patients with (Solo Model 0.87; Paired Model 0.95) and 132 patients without (Solo Model 0.84; Paired Model 0.95) a corroborating electrophysiology procedure or intracardiac device recording. CONCLUSION: Accurate WCT differentiation may be accomplished using computerized data of (i) the WCT ECG alone and (ii) paired WCT and baseline ECGs.


Asunto(s)
Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Electrocardiografía/métodos , Diagnóstico Diferencial , Taquicardia Ventricular/diagnóstico
14.
J Cardiovasc Electrophysiol ; 33(9): 2072-2080, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35870183

RESUMEN

INTRODUCTION: Cardiac sarcoidosis (CS) is a nonischemic cardiomyopathy (NICM) characterized by infiltration of noncaseating granulomas involving the heart with highly variable clinical manifestations that can include conduction abnormalities and systolic heart failure. Cardiac resynchronization therapy (CRT) has shown significant promise in NICM, though little is known about its efficacy in patients with CS. OBJECTIVE: To determine if CRT improved cardiac remodeling in patients with CS. METHODS: We retrospectively reviewed all patients with a clinical or histological diagnosis of CS who underwent CRT implantation at the Mayo Clinic enterprise from 2000 to 2021. Baseline characteristics, imaging parameters, heart failure hospitalizations and need for advanced therapies, and major adverse cardiac events (MACE) were assessed. RESULTS: Our cohort was comprised of 55 patients with 61.8% male and a mean age of 58.7 ± 10.9 years. Eighteen (32.7%) patients had definite CS, 21 (38.2%) had probable CS, while 16 (29.1%) had presumed CS, and 26 (47.3%) with extracardiac sarcoidosis. The majority underwent CRT-D implantation (n = 52, 94.5%) and 3 (5.5%) underwent CRT-P implantation with 67.3% of implanted devices being upgrades from prior pacemakers or implantable cardioverter defibrillators. At 6 months postimplantation there was no significant improvement in ejection fraction (34.8 ± 10.9% vs. 37.7 ± 14.2%, p = .331) or left ventricular end-diastolic diameter (58.5 ± 10.2 vs. 57.5 ± 8.1 mm, p = .236), though mild improvement in left ventricular end systolic diameter (49.1 ± 9.9 vs. 45.7± 9.9 mm, p < .0001). Within the first 6 months postimplantation, 5 (9.1%) patients sustained a heart failure hospitalization. At a mean follow-up of 4.1± 3.7 years, 14 (25.5%) patients experienced a heart failure hospitalization, 11 (20.0%) underwent cardiac transplantation, 1 (1.8%) underwent left ventricular assist device implantation and 7 (12.7%) patients died. CONCLUSIONS: Our findings suggest variable response to CRT in patients with CS with no overall improvement in ventricular function within 6 months and a substantial proportion of patients progressing to advanced heart failure therapies.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiomiopatías , Desfibriladores Implantables , Insuficiencia Cardíaca , Miocarditis , Sarcoidosis , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/etiología , Cardiomiopatías/terapia , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Miocarditis/etiología , Estudios Retrospectivos , Sarcoidosis/diagnóstico , Sarcoidosis/terapia , Resultado del Tratamiento
15.
J Cardiovasc Electrophysiol ; 33(2): 274-283, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34911151

RESUMEN

BACKGROUND: Data regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following mitral valve surgery (MVS) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves. OBJECTIVE: To investigate the characteristics, safety, and outcomes of radiofrequency CA in patients with prior MVS and ventricular arrhythmias (VA). METHODS: We identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013 and December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri-operative complications, and outcomes. RESULTS: In our cohort, 31 patients (77% men, mean age 62.3 ± 10.8 years, left ventricular ejection fraction 39.2 ± 13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans-septal approach in one patient. Heterogenous scar regions were present in 94% of VT patients and scar-related reentry was the dominant mechanism of VT. Forty-seven percent of PVC patients had abnormal substrate at the site targeted for ablation. Clinical VA substrates involved the peri-mitral area in six patients with VT and five patients with PVC ablation. No procedure-related complications were reported. The overall recurrence-free rate at 1-year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia-related death was documented on long-term follow-up. CONCLUSION: CA of VAs can be performed safely and effectively in patients with MVS.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Anciano , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Volumen Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Función Ventricular Izquierda , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/etiología , Complejos Prematuros Ventriculares/cirugía
16.
Ann Noninvasive Electrocardiol ; 27(1): e12890, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34562325

RESUMEN

BACKGROUND: Automated wide complex tachycardia (WCT) differentiation into ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) may be accomplished using novel calculations that quantify the extent of mean electrical vector changes between the WCT and baseline electrocardiogram (ECG). At present, it is unknown whether quantifying mean electrical vector changes within three orthogonal vectorcardiogram (VCG) leads (X, Y, and Z leads) can improve automated VT and SWCT classification. METHODS: A derivation cohort of paired WCT and baseline ECGs was used to derive five logistic regression models: (i) one novel WCT differentiation model (i.e., VCG Model), (ii) three previously developed WCT differentiation models (i.e., WCT Formula, VT Prediction Model, and WCT Formula II), and (iii) one "all-inclusive" model (i.e., Hybrid Model). A separate validation cohort of paired WCT and baseline ECGs was used to trial and compare each model's performance. RESULTS: The VCG Model, composed of WCT QRS duration, baseline QRS duration, absolute change in QRS duration, X-lead QRS amplitude change, Y-lead QRS amplitude change, and Z-lead QRS amplitude change, demonstrated effective WCT differentiation (area under the curve [AUC] 0.94) for the derivation cohort. For the validation cohort, the diagnostic performance of the VCG Model (AUC 0.94) was similar to that achieved by the WCT Formula (AUC 0.95), VT Prediction Model (AUC 0.91), WCT Formula II (AUC 0.94), and Hybrid Model (AUC 0.95). CONCLUSION: Custom calculations derived from mathematically synthesized VCG signals may be used to formulate an effective means to differentiate WCTs automatically.


Asunto(s)
Taquicardia Supraventricular , Taquicardia Ventricular , Diagnóstico Diferencial , Electrocardiografía , Humanos , Modelos Logísticos , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico
17.
J Electrocardiol ; 74: 32-39, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35933848

RESUMEN

BACKGROUND: Timely and accurate discrimination of wide complex tachycardias (WCTs) into ventricular tachycardia (VT) or supraventricular WCT (SWCT) is critically important. Previously we developed and validated an automated VT Prediction Model that provides a VT probability estimate using the paired WCT and baseline 12-lead ECGs. Whether this model improves physicians' diagnostic accuracy has not been evaluated. OBJECTIVE: We sought to determine whether the VT Prediction Model improves physicians' WCT differentiation accuracy. METHODS: Over four consecutive days, nine physicians independently interpreted fifty WCT ECGs (25 VTs and 25 SWCTs confirmed by electrophysiological study) as either VT or SWCT. Day 1 used the WCT ECG only, Day 2 used the WCT and baseline ECG, Day 3 used the WCT ECG and the VT Prediction Model's estimation of VT probability, and Day 4 used the WCT ECG, baseline ECG, and the VT Prediction Model's estimation of VT probability. RESULTS: Inclusion of the VT Prediction Model data increased diagnostic accuracy versus the WCT ECG alone (Day 3: 84.2% vs. Day 1: 68.7%, p 0.009) and WCT and baseline ECGs together (Day 3: 84.2% vs. Day 2: 76.4%, p 0.003). There was no further improvement of accuracy with addition of the baseline ECG comparison to the VT Prediction Model (Day 3: 84.2% vs. Day 4: 84.0%, p 0.928). Overall sensitivity (Day 3: 78.2% vs. Day 1: 67.6%, p 0.005) and specificity (Day 3: 90.2% vs. Day 1: 69.8%, p 0.016) for VT were superior after the addition of the VT Prediction Model. CONCLUSION: The VT Prediction Model improves physician ECG diagnostic accuracy for discriminating WCTs.


Asunto(s)
Electrocardiografía , Médicos , Humanos
18.
Europace ; 23(2): 247-253, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-32929501

RESUMEN

AIMS: The Food and Drug Administration (FDA) approval of the Watchman device [percutaneous left atrial appendage occlusion (LAAO)] has resulted in the widespread use of this procedure in many centres across the USA. We sought to estimate the nationwide utilization and frequency of adverse outcomes associated with Watchman device implantation. The objective of this study was to evaluate the Watchman device implantation peri-procedural complications and comparison of the results with the previous studies. METHODS AND RESULTS: The National Inpatient Sample (NIS) was queried for all hospitalizations with a primary diagnosis of atrial fibrillation or atrial flutter during the year 2016 with percutaneous LAAO during the same admission (ICD-10 code-02L73DK). The frequency of peri-procedural complications, including mortality, procedure-related stroke, major bleeding requiring blood transfusion, and pericardial effusion, was assessed. We compared the complication rates with the published randomized controlled trials and the European Watchman registry. An estimated 5175 LAAO procedures were performed in 2016. The majority of procedures was performed in males (59.1%), age ≥75 years (58.7%), and White (83.1%). The overall complication rate was 1.9%. The in-hospital mortality was 0.29%. Pericardial effusion requiring pericardiocentesis was the most frequent complication (0.68%). Bleeding requiring transfusion was noted in 0.1% of device implants. The rates of post-procedure stroke and systemic embolism were 0% and 0.29%, respectively. CONCLUSION: Percutaneous LAAO with the Watchman device in the USA is associated with low in-hospital complications and a similar safety profile to a recently published EWOLUTION cohort. The complication rates were lower than those reported in the major randomized clinical trials (RCTs). We report the frequency of peri-procedural complications of the LAAO using the Watchman device from the NIS database. We also compare the frequency of peri-procedural complications with the previously published RCTs and EWOLUTION cohort. Our findings are in concordance with findings from EWOLUTION cohort and compare favourably with RCTs.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Hemorragia , Humanos , Masculino , Resultado del Tratamiento
19.
J Electrocardiol ; 65: 50-54, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33503517

RESUMEN

Accurate wide QRS complex tachycardia (WCT) differentiation into either ventricular tachycardia or supraventricular wide complex tachycardia using 12­lead electrocardiogram (ECG) interpretation is essential for diagnostic, therapeutic, and prognostic reasons. There is an ever-expanding variety of WCT differentiation methods and criteria available to clinicians. However, only a few make use of the diagnostic value of comparing the ECG during WCT to that of the patient's baseline ECG. Therefore, we highlight the conceptual rationale and scientific literature supporting the diagnostic value of WCT and baseline ECG comparison.


Asunto(s)
Taquicardia Supraventricular , Taquicardia Ventricular , Diagnóstico Diferencial , Electrocardiografía , Humanos , Pronóstico , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico
20.
J Cardiovasc Electrophysiol ; 31(11): 3031-3035, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32786037

RESUMEN

In pacemaker-dependent patients with a newly implanted cardiac device, acute lead dislodgement constitutes one of the most common causes of loss of capture and ventricular asystole. In a biventricular system, it would be expected that such a potentially catastrophic event would be prevented with back-up right ventricular pacing unless both leads dislodge.


Asunto(s)
Paro Cardíaco , Insuficiencia Cardíaca , Marcapaso Artificial , Estimulación Cardíaca Artificial , Paro Cardíaco/diagnóstico , Paro Cardíaco/etiología , Paro Cardíaco/terapia , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Humanos , Marcapaso Artificial/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA