Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Kidney Int ; 105(2): 338-346, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37918791

RESUMEN

Precise determination of circulating parathyroid hormone (PTH) concentration is crucial to diagnose and manage various disease conditions, including the chronic kidney disease-mineral and bone disorder. However, the lack of standardization in PTH assays is challenging for clinicians, potentially leading to medical errors because the different assays do not provide equivalent results and use different reference ranges. Here, we aimed to evaluate the impact of recalibrating PTH immunoassays by means of a recently developed LC-MS/MS method as the reference. Utilizing a large panel of pooled plasma samples with PTH concentrations determined by the LC-MS/MS method calibrated with the World Health Organization (WHO) 95/646 International Standard, five PTH immunoassays were recalibrated. The robustness of this standardization was evaluated over time using different sets of samples. The recalibration successfully reduced inter-assay variability with harmonization of PTH measurements across different assays. By recalibrating the assays based on the WHO 95/646 International Standard, we demonstrated the feasibility for standardizing PTH measurement results and adopting common reference ranges for PTH assays, facilitating a more consistent interpretation of PTH values. The recalibration process aligns PTH results obtained from various immunoassays with the LC-MS/MS method, providing more consistent and reliable measurements. Thus, establishing true standardization across all PTH assays is crucial to ensure consistent interpretation and clinical decision-making.


Asunto(s)
Trastorno Mineral y Óseo Asociado a la Enfermedad Renal Crónica , Insuficiencia Renal Crónica , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem , Hormona Paratiroidea , Insuficiencia Renal Crónica/diagnóstico
2.
Clin Chem ; 2024 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-39316470

RESUMEN

BACKGROUND: In previous publications, the Task Force on Reference Measurement System Implementation proposed a procedural approach combining a critical review of entries available in the Joint Committee on Traceability in Laboratory Medicine (JCTLM) database with a comparison of this information against analytical performance specifications for measurement uncertainty (MU) and applied it to a group of 13 measurands. CONTENT: Here we applied this approach to 17 additional measurands, of which measurements are frequently requested. The aims of the study were (a) to describe the main characteristics for implementing traceability and the potential to fulfill the maximum allowable MU (MAU) at the clinical sample level of certified reference materials and reference measurement procedures listed in the JCTLM database; (b) to discuss limitations and obstacles, if any, to the achievement of the required quality of laboratory measurements; and (c) to provide a gap analysis by highlighting what is still missing in the database. Results were integrated with those obtained in the previous study, therefore offering an overview of where we are and what is still missing in the practical application of the metrological traceability concept to 30 common biochemical tests employed in laboratory medicine. SUMMARY: Our analysis shows that for 28 out of 30 measurands, conditions exist to correctly implement metrological traceability to the International System of units and fulfill at least the MAU of the minimum quality level derived according to internationally recommended models. For 2 measurands (serum albumin and chloride), further improvements in MU of higher-order references would be necessary.

3.
Clin Chem Lab Med ; 62(10): 1892-1903, 2024 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-39066506

RESUMEN

Measurement of total bilirubin (TBil) concentration in serum is the gold standard approach for diagnosing neonatal unconjugated hyperbilirubinemia. It is of utmost importance that the measured TBil concentration is sufficiently accurate to prevent under treatment, unnecessary escalation of care, or overtreatment. However, it is widely recognized that TBil measurements urgently require improvement in neonatal clinical chemistry. External quality assessment (EQA) programs for TBil assess for differences between laboratories and provide supporting evidence of significant differences between various methods, manufacturers and measurement platforms. At the same time, many countries have adopted or only slightly adapted the neonatal hyperbilirubinemia management guidelines from the USA or UK, often without addressing differences in the methodology of TBil measurements. In this report, we provide an overview of the components of bilirubin that are measured by laboratory platforms, the availability of current reference measurement procedures and reference materials, and the role of EQA surveys in this context. Furthermore, the current status of agreement in neonatal bilirubin against clinical decision thresholds is reviewed. We advocate for enhancements in accuracy and comparability of neonatal TBil measurements, propose a path forward to accomplish this, and reflect on the position of the International Federation for Clinical Chemistry and Laboratory Medicine (IFCC) Working Group Neonatal Bilirubin (WG-NB) in this matter.


Asunto(s)
Bilirrubina , Hiperbilirrubinemia Neonatal , Humanos , Recién Nacido , Bilirrubina/sangre , Hiperbilirrubinemia Neonatal/sangre , Hiperbilirrubinemia Neonatal/diagnóstico , Hiperbilirrubinemia Neonatal/terapia , Estándares de Referencia
4.
Clin Chem ; 69(11): 1227-1237, 2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37725906

RESUMEN

It is important for external quality assessment materials (EQAMs) to be commutable with clinical samples; i.e., they should behave like clinical samples when measured using end-user clinical laboratory in vitro diagnostic medical devices (IVD-MDs). Using commutable EQAMs makes it possible to evaluate metrological traceability and/or equivalence of results between IVD-MDs. The criterion for assessing commutability of an EQAM between 2 IVD-MDs is that its result should be within the prediction interval limits based on the statistical distribution of the clinical sample results from the 2 IVD-MDs being compared. The width of the prediction interval is, among other things, dependent on the analytical performance characteristics of the IVD-MDs. A presupposition for using this criterion is that the differences in nonselectivity between the 2 IVD-MDs being compared are acceptable. An acceptable difference in nonselectivity should be small relative to the analytical performance specifications used in the external quality assessment scheme. The acceptable difference in nonselectivity is used to modify the prediction interval criterion for commutability assessment. The present report provides recommendations on how to establish a criterion for acceptable commutability for EQAMS, establish the difference in nonselectivity that can be accepted between IVD-MDs, and perform a commutability assessment. The report also contains examples for performing a commutability assessment of EQAMs.


Asunto(s)
Servicios de Laboratorio Clínico , Ensayos de Aptitud de Laboratorios , Humanos , Estándares de Referencia , Juego de Reactivos para Diagnóstico
5.
Clin Chem ; 69(3): 251-261, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36644914

RESUMEN

BACKGROUND: Medical results generated by European CE Marking for In Vitro Diagnostic or in-house tests should be traceable to higher order reference measurement systems (RMS), such as International Federation of Clinical Chemistry and Laboratory Medicine (IFCC)-endorsed reference measurement procedures (RMPs) and reference materials. Currently, serum apolipoprotein (a) [apo(a)] is recognized as a novel risk factor for cardiovascular risk assessment and patient management. The former RMS for serum apo(a) is no longer available; consequently, an International System of Units (SI)-traceable, ideally multiplexed, and sustainable RMS for apo(a) is needed. METHODS: A mass spectrometry (MS)-based candidate RMP (cRMP) for apo(a) was developed using quantitative bottom-up proteomics targeting 3 proteotypic peptides. The method was provisionally validated according to ISO 15193 using a single human serum based calibrator traceable to the former WHO-IFCC RMS. RESULTS: The quantitation of serum apo(a) was by design independent of its size polymorphism, was linear from 3.8 to 456 nmol/L, and had a lower limit of quantitation for apo(a) of 3.8 nmol/L using peptide LFLEPTQADIALLK. Interpeptide agreement showed Pearson Rs of 0.987 and 0.984 for peptides GISSTVTGR and TPENYPNAGLTR, and method comparison indicated good correspondence (slopes 0.977, 1.033, and 1.085 for LFLEPTQADIALLK, GISSTVTGR, and TPENYPNAGLTR). Average within-laboratory imprecision of the cRMP was 8.9%, 11.9%, and 12.8% for the 3 peptides. CONCLUSIONS: A robust, antibody-independent, MS-based cRMP was developed as higher order RMP and an essential part of the apo(a) traceability chain and future RMS. The cRMP fulfils predefined analytical performance specifications, making it a promising RMP candidate in an SI-traceable MS-based RMS for apo(a).


Asunto(s)
Péptidos , Suero , Humanos , Apoproteína(a) , Espectrometría de Masas , Estándares de Referencia , Calibración
6.
Clin Chem ; 69(3): 262-272, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36644921

RESUMEN

BACKGROUND: Elevated concentrations of lipoprotein(a) [Lp(a)] are directly related to an increased risk of cardiovascular diseases, making it a relevant biomarker for clinical risk assessment. However, the lack of global standardization of current Lp(a) measurement procedures (MPs) leads to inconsistent patient care. The International Federation for Clinical Chemistry and Laboratory Medicine working group on quantitating apolipoproteins by mass spectrometry (MS) aims to develop a next-generation SI (International system of units)-traceable reference measurement system consisting of a MS-based, peptide-calibrated reference measurement procedure (RMP) and secondary serum-based reference materials (RMs) certified for their apolipoprotein(a) [apo(a)] content. To reach measurement standardization through this new measurement system, 2 essential requirements need to be fulfilled: a sufficient correlation among the MPs and appropriate commutability of future serum-based RMs. METHODS: The correlation among the candidate RMP (cRMP) and immunoassay-based MPs was assessed by measuring a panel of 39 clinical samples (CS). In addition, the commutability of 14 different candidate RMs was investigated. RESULTS: Results of the immunoassay-based MPs and the cRMPs demonstrated good linear correlations for the CS but some significant sample-specific differences were also observed. The results of the commutability study show that RMs based on unspiked human serum pools can be commutable with CS, whereas human pools spiked with recombinant apo(a) show different behavior compared to CS. CONCLUSIONS: The results of this study show that unspiked human serum pools are the preferred candidate secondary RMs in the future SI-traceable Lp(a) Reference Measurement System.


Asunto(s)
Química Clínica , Lipoproteína(a) , Humanos , Inmunoensayo , Espectrometría de Masas , Estándares de Referencia
7.
Clin Chem ; 69(9): 966-975, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37566391

RESUMEN

A secondary higher-order calibrator is required to be commutable with clinical samples to be suitable for use in the calibration hierarchy of an end-user clinical laboratory in vitro diagnostic medical device (IVD-MD). Commutability is a property of a reference material that means results for a reference material and for clinical samples have the same numeric relationship, within specified limits, across the measurement procedures for which the reference material is intended to be used. Procedures for assessing commutability have been described in the literature. This report provides recommendations for establishing a quantitative criterion to assess the commutability of a certified reference material (CRM). The criterion is the maximum allowable noncommutability bias (MANCB) that allows a CRM to be used as a calibrator in a calibration hierarchy for an IVD-MD without exceeding the maximum allowable combined standard uncertainty for a clinical sample result (umaxCS). Consequently, the MANCB is derived as a fraction of the umaxCS for the measurand. The suitability of an MANCB for practical use in a commutability assessment is determined by estimating the number of measurements of clinical samples and CRMs required based on the precision performance and nonselectivity for the measurand of the measurement procedures in the assessment. Guidance is also provided for evaluating indeterminate commutability conclusions and how to report results of a commutability assessment.

8.
Clin Chem Lab Med ; 61(7): 1235-1244, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-36815732

RESUMEN

OBJECTIVES: In clinical pratice, tau protein measurement generally relies on immunoassays (IAs), whose major drawback is the lack of results comparability due to differences in selectivity and/or calibration. This underlines the importance of establishing a traceability chain for total tau (t-tau) measurements. The objective of this work is to develop a higher order candidate reference measurement procedure (RMP) for the absolute quantification of t-tau in cerebrospinal fluid (CSF). METHODS: To calibrate the candidate RMP and establish metrological traceability to the SI units, a primary calibrator consisting in a highly purified recombinant protein was sourced. Its purity was evaluated by liquid chromatography coupled with high resolution mass spectrometry (LC-HRMS) and the protein mass fraction in solution was certified by amino acid analysis (AAA). An isotopically-labelled homologue was obtained to develop a candidate RMP by isotope dilution mass spectrometry (IDMS) for t-tau absolute quantification in CSF. Calibration blends and quality control (QC) materials were gravimetrically prepared and subjected to the same preparation workflow as CSF samples, followed by LC-HRMS analysis in Parallel Reaction Monitoring (PRM) mode. RESULTS: A primary calibrator has been developed and an IDMS candidate RMP has been validated for CSF t-tau. The candidate RMP was used to certify t-tau concentration in three pools of CSF (low, medium, high). CONCLUSIONS: The candidate RMP will pave the road towards global standardization of CSF t-tau measurements. Together with commutable Certified Reference Materials (CRMs), it will allow evaluating and improving the accuracy and comparability of results provided by IAs.


Asunto(s)
Espectrometría de Masas en Tándem , Proteínas tau , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Estándares de Referencia , Aminoácidos/análisis , Calibración
9.
Clin Chem Lab Med ; 61(7): 1245-1254, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-36709509

RESUMEN

OBJECTIVES: Neurofilament light chain (NfL) concentration in blood is a biomarker of neuro-axonal injury in the nervous system and there now exist several assays with high enough sensitivity to measure NfL in serum and plasma. There is a need for harmonization with the goal of creating a certified reference material (CRM) for NfL and an early step in such an effort is to determine the best matrix for the CRM. This is done in a commutability study and here the results of the first one for NfL in blood is presented. METHODS: Forty paired individual serum and plasma samples were analyzed for NfL on four different analytical platforms. Neat and differently spiked serum and plasma were evaluated for their suitability as a CRM using the difference in bias approach. RESULTS: The correlation between the different platforms with regards to measured NfL concentrations were very high (Spearman's ρ≥0.96). Samples spiked with cerebrospinal fluid (CSF) showed higher commutability compared to samples spiked with recombinant human NfL protein and serum seems to be a better choice than plasma as the matrix for a CRM. CONCLUSIONS: The results from this first commutability study on NfL in serum/plasma showed that it is feasible to create a CRM for NfL in blood and that spiking should be done using CSF rather than with recombinant human NfL protein.


Asunto(s)
Filamentos Intermedios , Proteínas de Neurofilamentos , Humanos , Suero , Plasma , Estándares de Referencia , Biomarcadores , Proteínas Recombinantes
10.
Lancet ; 397(10279): 1085-1094, 2021 03 20.
Artículo en Inglés | MEDLINE | ID: mdl-33711294

RESUMEN

BACKGROUND: In cardiovascular disease, prevention strategies targeting standard modifiable cardiovascular risk factors (SMuRFs; hypertension, diabetes, hypercholesterolaemia, and smoking) are crucial; however, myocardial infarction in the absence of SMuRFs is not infrequent. The outcomes of individuals without SMuRFs are not well known. METHODS: We retrospectively analysed adult patients with first-presentation ST-elevation myocardial infarction (STEMI) using data from the Swedish myocardial infarction registry SWEDEHEART. Clinical characteristics and outcomes of adult patients (age ≥18 years) with and without SMuRFs were examined overall and by sex. Patients with a known history of coronary artery disease were excluded. The primary outcome was all-cause mortality at 30 days after STEMI presentation. Secondary outcomes included cardiovascular mortality, heart failure, and myocardial infarction at30 days. Endpoints were also examined up to discharge, and to the end of a 12-year follow-up. Multivariable logistic regression models were used to compare in-hospital mortality, and Cox-proportional hazard models and Kaplan-Meier analysis for long-term outcomes. FINDINGS: Between Jan 1, 2005, and May 25, 2018, 9228 (14·9%) of 62 048 patients with STEMI had no SMuRFs reaching diagnostic thresholds. Median age was similar between patients with SMuRFs and patients without SMuRFs (68 years [IQR 59-78]) vs 69 years [60-78], p<0·0001). SMuRF-less patients had a similar rate of percutaneous coronary intervention to those with at least one modifiable risk factor, but were significantly less likely to receive statins, angiotensin converting enzyme inhibitors (ACEIs) or angiotensin receptor blockade (ARB), or ß-blockers at discharge. By 30 days after presentation, all-cause mortality was significantly higher in SMuRF-less patients (hazard ratio 1·47 [95% CI 1·37-1·57], p<0·0001). SMuRF-less women had the highest 30-day mortality (381 [17·6%] of 2164), followed by women with SMuRFs (2032 [11·1%] of 18 220), SMuRF-less men (660 [9·3%] of 7064), and men with SMuRFs (2117 [6·1%] of 34 600). The increased risk of 30-day all-cause mortality in SMuRF-less patients remained significant after adjusting for age, sex, left ventricular ejection fraction, creatinine, and blood pressure, but was attenuated on inclusion of pharmacotherapy prescription (ACEI or ARB, ß-blocker, or statin) at discharge. Additionally, SMuRF-less patients had a significantly higher rate of in-hospital all-cause mortality than patients with one or more SMuRF (883 [9·6%] vs 3411 [6·5%], p<0·0001). Myocardial infarction and heart failure at 30 days were lower in SMuRF-less patients. All-cause mortality remained increased in the SMuRF-less group for more than 8 years in men and up to the 12-year endpoint in women. INTERPRETATION: Individuals who present with STEMI in the absence of SMuRFs have a significantly increased risk of all-cause mortality, compared with those with at least one SMuRF, which was particularly evident in women. The increased early mortality rates are attenuated after adjustment for use of guideline-indicated treatments, highlighting the need for evidence-based pharmacotherapy during the immediate post-infarct period irrespective of perceived low risk. FUNDING: Swedish Heart and Lung Foundation, National Health and Medical Research Council (Australia).


Asunto(s)
Quimioterapia/normas , Insuficiencia Cardíaca/mortalidad , Mortalidad Hospitalaria/tendencias , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/estadística & datos numéricos , Infarto del Miocardio con Elevación del ST/mortalidad , Antagonistas Adrenérgicos beta/uso terapéutico , Anciano , Antagonistas de Receptores de Angiotensina/uso terapéutico , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Diabetes Mellitus/tratamiento farmacológico , Diabetes Mellitus/prevención & control , Quimioterapia/métodos , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Hipercolesterolemia , Hipertensión/tratamiento farmacológico , Hipertensión/prevención & control , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/epidemiología , Infarto del Miocardio/etiología , Evaluación de Resultado en la Atención de Salud , Sistema de Registros , Estudios Retrospectivos , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/fisiopatología , Prevención del Hábito de Fumar/normas , Suecia/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA