1.
Comput Biol Med ; 125: 103962, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32841766

RESUMEN

Chronic thromboembolic pulmonary hypertension (CTEPH) is a possible complication of pulmonary embolism (PE), with poor prognosis if left untreated. Surgical curative treatment is available, particularly in the early stages of the disease. However, most cases are not diagnosed until specific symptoms become evident. A small number of computed tomography (CT) findings, such as a widened pulmonary artery and mosaicism in the lung parenchyma, have been correlated with pulmonary hypertension (PH). Quantitative texture analysis in the CT scans of these patients could provide complementary sub-visual information of the vascular changes taking place in the lungs. For this task, a lung graph model was developed with texture descriptors from 37 CT scans with confirmed CTEPH diagnosis and 48 CT scans from PE patients who did not develop PH. The probability of presenting CTEPH, computed with the graph model, outperformed a convolutional neural network approach using 10 different train/test splits of the data set. An accuracy of 0.76 was obtained with the proposed texture analysis, and was then compared to the visual assessment of CT findings, manually identified by a team of three expert radiologists, commonly associated with pulmonary hypertension. This graph-based score combined with the information attained from the radiological findings resulted in a Cohen's kappa coefficient of 0.47 when differentiating patients with confirmed CTEPH from those with PE who did not develop the disease. The proposed texture quantification could be an objective measurement, complementary to the current analysis of radiologists for the early detection of CTEPH and thus improve patient outcome.


Asunto(s)
Hipertensión Pulmonar , Embolia Pulmonar , Enfermedad Crónica , Humanos , Hipertensión Pulmonar/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Arteria Pulmonar , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X
2.
IEEE Trans Image Process ; 26(4): 1899-1910, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28186890

RESUMEN

Many image acquisition techniques used in biomedical imaging, material analysis, and structural geology are capable of acquiring 3-D solid images. Computational analysis of these images is complex but necessary since it is difficult for humans to visualize and quantify their detailed 3-D content. One of the most common methods to analyze 3-D data is to characterize the volumetric texture patterns. Texture analysis generally consists of encoding the local organization of image scales and directions, which can be extremely diverse in 3-D. Current state-of-the- art techniques face many challenges when working with 3-D solid texture, where most approaches are not able to consistently characterize both scale and directional information. 3-D Riesz- wavelets can deal with both properties. One key property of Riesz filterbanks is steerability, which can be used to locally align the filters and compare textures with arbitrary (local) orientations. This paper proposes and compares three novel local alignment criteria for higher-order 3-D Riesz-wavelet transforms. The estimations of local texture orientations are based on higher- order extensions of regularized structure tensors. An experimental evaluation of the proposed methods for the classification of synthetic 3-D solid textures with alterations (such as rotations and noise) demonstrated the importance of local directional information for robust and accurate solid texture recognition. These alignment methods improved the accuracy of the unaligned Riesz descriptors up to 0.63, from 0.32 to 0.95 over 1 in the rotated data, which is better than all other techniques that are published and tested on the same database.

3.
IEEE Trans Med Imaging ; 35(12): 2620-2630, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27429433

RESUMEN

This paper proposes a novel imaging biomarker of lung cancer relapse from 3-D texture analysis of CT images. Three-dimensional morphological nodular tissue properties are described in terms of 3-D Riesz-wavelets. The responses of the latter are aggregated within nodular regions by means of feature covariances, which leverage rich intra- and inter-variations of the feature space dimensions. When compared to the classical use of the average for feature aggregation, feature covariances preserve spatial co-variations between features. The obtained Riesz-covariance descriptors lie on a manifold governed by Riemannian geometry allowing geodesic measurements and differentiations. The latter property is incorporated both into a kernel for support vector machines (SVM) and a manifold-aware sparse regularized classifier. The effectiveness of the presented models is evaluated on a dataset of 110 patients with non-small cell lung carcinoma (NSCLC) and cancer recurrence information. Disease recurrence within a timeframe of 12 months could be predicted with an accuracy of 81.3-82.7%. The anatomical location of recurrence could be discriminated between local, regional and distant failure with an accuracy of 78.3-93.3%. The obtained results open novel research perspectives by revealing the importance of the nodular regions used to build the predictive models.


Asunto(s)
Neoplasias Pulmonares , Humanos , Recurrencia Local de Neoplasia , Máquina de Vectores de Soporte , Tomografía Computarizada por Rayos X
4.
IEEE Trans Med Imaging ; 35(11): 2459-2475, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27305669

RESUMEN

Variations in the shape and appearance of anatomical structures in medical images are often relevant radiological signs of disease. Automatic tools can help automate parts of this manual process. A cloud-based evaluation framework is presented in this paper including results of benchmarking current state-of-the-art medical imaging algorithms for anatomical structure segmentation and landmark detection: the VISCERAL Anatomy benchmarks. The algorithms are implemented in virtual machines in the cloud where participants can only access the training data and can be run privately by the benchmark administrators to objectively compare their performance in an unseen common test set. Overall, 120 computed tomography and magnetic resonance patient volumes were manually annotated to create a standard Gold Corpus containing a total of 1295 structures and 1760 landmarks. Ten participants contributed with automatic algorithms for the organ segmentation task, and three for the landmark localization task. Different algorithms obtained the best scores in the four available imaging modalities and for subsets of anatomical structures. The annotation framework, resulting data set, evaluation setup, results and performance analysis from the three VISCERAL Anatomy benchmarks are presented in this article. Both the VISCERAL data set and Silver Corpus generated with the fusion of the participant algorithms on a larger set of non-manually-annotated medical images are available to the research community.


Asunto(s)
Algoritmos , Puntos Anatómicos de Referencia/diagnóstico por imagen , Anatomía/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Anciano , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS