Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 151
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 32(8): 2238-2245, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34165227

RESUMEN

PURPOSE: We sought to study the predictive value of the metabolic heterogeneous zone (HZ) as determined by 18 Fluorodeoxyglucose (18 FDG) positron emission tomography (PET) viability studies in ventricular tachycardia (VT) patients. METHODS: PET studies utilizing 82 Rubidium (82 Rb) tracer for perfusion and 18 FDG tracer for viability were analyzed using PMOD (PMOD Technologies) and further analyzed using 684-segment plots. 18 FDG uptake was normalized to the area with maximal perfusion on the rest 82 Rb study. Metabolic scar, HZ, and healthy segments were defined with perfusion-normalized 18 FDG uptake between 0%-50%, 50%-70%, and >70%, respectively. RESULTS: Thirty-four VT patients (age, 63 ± 12 years) were evaluated with 18 FDG-PET viability study. Most (n = 31) patients underwent VT ablation. Patients were categorized to HZ < median versus HZ ≥ median based on a median HZ area size of 21.0 cm2 . HZ size was significantly larger in the deceased group than the alive group (35.2 cm2 vs. 18.1 cm2 , p = .01). Deaths were significantly higher in HZ ≥ 21 cm2 group than HZ < 21 cm2 group (58.8% vs. 11.8%, p = .005). Survival analysis showed significantly higher mortality in the HZ ≥ 21 cm2 group than the HZ < 21 cm2 group (HR = 4.1, 95% CI: 1.3-12.6, p = .016). In a multivariable analysis, HZ was found to be an independent predictor for all-cause mortality (HR = 1.07, 95% CI: 1.02-1.12, p = .01) CONCLUSIONS: Increased HZ size of myocardium was associated with increased mortality. Metabolic HZ quantification may be of value in risk stratification and management of ischemic and nonischemic patients with VT.


Asunto(s)
Fluorodesoxiglucosa F18 , Taquicardia Ventricular , Anciano , Cicatriz/patología , Humanos , Persona de Mediana Edad , Miocardio/patología , Tomografía de Emisión de Positrones , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/patología , Taquicardia Ventricular/cirugía
2.
J Cardiovasc Electrophysiol ; 32(2): 409-416, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33355965

RESUMEN

INTRODUCTION: Patients with prior cardiac surgery may represent a subgroup of patients with ventricular tachycardia (VT) that may be more difficult to control with catheter ablation. METHODS: We evaluated 1901 patients with ischemic and nonischemic cardiomyopathy who underwent VT ablation at 12 centers. Clinical characteristics and VT radiofrequency ablation procedural outcomes were assessed and compared between those with and without prior cardiac surgery. Kaplan-Meier analysis was used to estimate freedom from recurrent VT and survival. RESULTS: There were 578 subjects (30.4%) with prior cardiac surgery identified in the cohort. Those with prior cardiac surgery were older (66.4 ± 11.0 years vs. 60.5 ± 13.9 years, p < .01), with lower left ventricular ejection fraction (30.2 ± 11.5% vs. 34.8 ± 13.6%, p < .01) and more ischemic heart disease (82.5% vs. 39.3%, p < .01) but less likely to undergo epicardial mapping or ablation (9.0% vs. 38.1%, p<.01) compared to those without prior surgery. When epicardial mapping was performed, a significantly greater proportion required surgical intervention for access (19/52 [36.5%] vs. 14/504 [2.8%]; p < .01). Procedural complications, including epicardial access-related complications, were lower (5.7% vs. 7.0%, p < .01) in patients with versus without prior cardiac surgery. VT-free survival (75.1% vs. 74.1%, p = .805) and survival (86.5% vs. 87.9%, p = .397) were not different between those with and without prior heart surgery, regardless of etiology of cardiomyopathy. VT recurrence was associated with increased mortality in patients with and without prior cardiac surgery. CONCLUSION: Despite different clinical characteristics and fewer epicardial procedures, the safety and efficacy of VT ablation in patients with prior cardiac surgery is similar to others in this cohort. The incremental yield of epicardial mapping in predominant ischemic cardiomyopathy population prior heart surgery may be low but appears safe in experienced centers.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Taquicardia Ventricular , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Ablación por Catéter/efectos adversos , Humanos , Pericardio/cirugía , Recurrencia , Volumen Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Función Ventricular Izquierda
4.
Europace ; 22(3): 450-495, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-31995197

RESUMEN

Ventricular arrhythmias are an important cause of morbidity and mortality and come in a variety of forms, from single premature ventricular complexes to sustained ventricular tachycardia and fibrillation. Rapid developments have taken place over the past decade in our understanding of these arrhythmias and in our ability to diagnose and treat them. The field of catheter ablation has progressed with the development of new methods and tools, and with the publication of large clinical trials. Therefore, global cardiac electrophysiology professional societies undertook to outline recommendations and best practices for these procedures in a document that will update and replace the 2009 EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias. An expert writing group, after reviewing and discussing the literature, including a systematic review and meta-analysis published in conjunction with this document, and drawing on their own experience, drafted and voted on recommendations and summarized current knowledge and practice in the field. Each recommendation is presented in knowledge byte format and is accompanied by supportive text and references. Further sections provide a practical synopsis of the various techniques and of the specific ventricular arrhythmia sites and substrates encountered in the electrophysiology lab. The purpose of this document is to help electrophysiologists around the world to appropriately select patients for catheter ablation, to perform procedures in a safe and efficacious manner, and to provide follow-up and adjunctive care in order to obtain the best possible outcomes for patients with ventricular arrhythmias.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Electrofisiología Cardíaca , Consenso , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía
5.
Pacing Clin Electrophysiol ; 43(3): 314-321, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32052461

RESUMEN

BACKGROUND: Cardiac magnetic resonance (CMR) characteristics of ventricular radiofrequency ablation (RFA) lesions have only been incompletely defined. AIM: To determine the detectability and imaging characteristics of ventricular RFA lesions in an unselected patient cohort undergoing ventricular arrhythmia ablation. METHODS AND RESULTS: A retrospective chart review (n = 249) identified 36 patients with either pre-/postablation CMR (n = 14) or only postablation CMR (n = 22). Ablation lesions could be identified in 50% (n = 18) of patients. Nonvisualized lesions had more preexisting transmural late gadolinium enhancement (LGE) >75% at the ablation sites (21% vs 0.0%, P = .042), more prevalent ICD artifact (50% vs 0%, P = .001), and lower ejection fraction (35.8 ± 14.2% vs 45.3 ± 13.4%, P = .048). Early CMR imaging demonstrated a central "black" signal void (microvascular obstruction [MVO], n = 12, 67%) up to 32 days post-RFA, whereas late imaging showed a homogenously "white" gadolinium enhancement pattern (n = 6, 33%). MVO was only observed in nonfibrotic myocardium without preexisting LGE (n = 12) but was not observed in the scar with preexisting LGE (n = 3, P = .002) suggesting different wash-in/wash-out kinetics in scar/nonscar myocardium. Signal intensity (1909 vs 2534, P = .009) and contrast-to-noise ratio (-7.8 vs 16.3, P = .009) were significantly different between MVO and LGE lesions, respectively. CONCLUSION: Ventricular ablation lesions visualization is negatively affected by preexisting transmural scar, ICD artifact, and low ejection fraction. The transition of "black" MVO appearance to "white" LGE appearance on CMR occurs around 1 month following ablation, suggesting a change in histological characteristics of ablation lesions. This may affect the utility of CMR in the evaluation of the ventricular lesions, when undergoing real-time or repeat VT ablations.


Asunto(s)
Ablación por Catéter , Imagen por Resonancia Cinemagnética/métodos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Complejos Prematuros Ventriculares/diagnóstico por imagen , Complejos Prematuros Ventriculares/cirugía , Medios de Contraste , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Meglumina/análogos & derivados , Persona de Mediana Edad , Compuestos Organometálicos , Estudios Retrospectivos , Taquicardia Ventricular/fisiopatología , Complejos Prematuros Ventriculares/fisiopatología
6.
Europace ; 21(8): 1143-1144, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31075787

RESUMEN

Ventricular arrhythmias are an important cause of morbidity and mortality and come in a variety of forms, from single premature ventricular complexes to sustained ventricular tachycardia and fibrillation. Rapid developments have taken place over the past decade in our understanding of these arrhythmias and in our ability to diagnose and treat them. The field of catheter ablation has progressed with the development of new methods and tools, and with the publication of large clinical trials. Therefore, global cardiac electrophysiology professional societies undertook to outline recommendations and best practices for these procedures in a document that will update and replace the 2009 EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias. An expert writing group, after reviewing and discussing the literature, including a systematic review and meta-analysis published in conjunction with this document, and drawing on their own experience, drafted and voted on recommendations and summarized current knowledge and practice in the field. Each recommendation is presented in knowledge byte format and is accompanied by supportive text and references. Further sections provide a practical synopsis of the various techniques and of the specific ventricular arrhythmia sites and substrates encountered in the electrophysiology lab. The purpose of this document is to help electrophysiologists around the world to appropriately select patients for catheter ablation, to perform procedures in a safe and efficacious manner, and to provide follow-up and adjunctive care in order to obtain the best possible outcomes for patients with ventricular arrhythmias.


Asunto(s)
Electrofisiología Cardíaca , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas/métodos , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Electrofisiología Cardíaca/organización & administración , Electrofisiología Cardíaca/normas , Electrofisiología Cardíaca/tendencias , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Ablación por Catéter/normas , Consenso , Sistema de Conducción Cardíaco/patología , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/cirugía , Cardiopatías/clasificación , Cardiopatías/complicaciones , Humanos , Cooperación Internacional , Mejoramiento de la Calidad/organización & administración , Sociedades Médicas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/etiología , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/cirugía
8.
Pacing Clin Electrophysiol ; 41(7): 870-871, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29746708

RESUMEN

A 72-year-old man who underwent a left atrial appendage (LAA) closure device 2 years ago presented with atrial flutter with rapid ventricular rate and was referred for cardioversion. Precardioversion transesophageal echocardiogram showed left atrial thrombus and therefore the procedure was aborted. Currently, there is no guideline on imaging surveillance or anticoagulation in patients with LAA closure device who develop intracardiac thrombus after the initial 6-month surveillance period.


Asunto(s)
Apéndice Atrial/cirugía , Cardiopatías/etiología , Complicaciones Posoperatorias/etiología , Prótesis e Implantes/efectos adversos , Trombosis/etiología , Anciano , Atrios Cardíacos , Humanos , Masculino , Factores de Tiempo
9.
Pacing Clin Electrophysiol ; 40(10): 1059-1066, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28722134

RESUMEN

BACKGROUND: A significant number of ventricular tachycardia circuits are located close to the epicardial surface and are amendable to epicardial ablation. Epicardial fat often interferes with substrate mapping and ablation, though little is known regarding the distribution of fat and its fluctuation with the cardiac cycle. METHODS: We studied 40 patients who underwent a 64-slice multidetector computed tomography in order to describe patterns of epicardial fat distribution, variation during cardiac cycle, and clinical predictors of epicardial fat. Multiplanar reconstructions were analyzed during systole and diastole in six cross-sections. Epicardial fat thickness was measured across multiple wall segments in each view. RESULTS: Epicardial fat was found to be thicker in areas overlying coronary vasculature (7.8 ± 2.6 mm vs 3.5 ± 0.9 mm, P = 0.001), along with the right ventricular wall (3.9 ± 0.8 mm vs 2.6 ± 0.6 mm, P = 0.001) and the ventricular base (6.1 ± 1.7 mm vs 4.6 ± 1.6 mm, P < 0.01). Epicardial fat thickness increased 27% during systole as compared to diastole (4.9 ± 2.7 mm vs 6.2 ± 3.0 mm, P = 0.04). Variation with cardiac cycle was most evident along the right ventricular wall (3.9 ± 0.8 mm vs 5.0 ± 1.3 mm, P = 0.001) and nonvascular areas (P = 0.001), especially at the ventricular base (3.7 ± 1.1 mm vs 5.3 ± 1.5 mm, P = 0.001). In multivariate logistic regression, we found that age >50 years (P = 0.031) and coronary artery disease (P = 0.023) were statistically correlated with epicardial fat >5-mm thickness and body mass index > 33 (P = 0.052) nearly so. CONCLUSIONS: Baseline epicardial fat thickness >5 mm is common in areas typically targeted during epicardial ablation and further increases during the cardiac cycle. Simple clinical characteristics can identify patients with >5 mm epicardial fat in which preprocedural computed tomography imaging and three-dimensional fat map reconstruction may facilitate epicardial ablation.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Ablación por Catéter/métodos , Mapeo Epicárdico/métodos , Tomografía Computarizada Multidetector , Pericardio/diagnóstico por imagen , Cirugía Asistida por Computador , Taquicardia Ventricular/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos
10.
Pacing Clin Electrophysiol ; 40(11): 1206-1212, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28901573

RESUMEN

INTRODUCTION: Visualization of left atrial (LA) anatomy using image integration modules has been associated with decreased radiation exposure and improved procedural outcome when used for guidance of pulmonary vein isolation (PVI) in atrial fibrillation (AF) ablation. We evaluated the CARTOSEG™ CT Segmentation Module (Biosense Webster, Inc.) that offers a new CT-specific semiautomatic reconstruction of the atrial endocardium. METHODS: The CARTOSEG™ CT Segmentation Module software was assessed prospectively in 80 patients undergoing AF ablation. Using preprocedural contrast-enhanced computed tomography (CE-CT), cardiac chambers, coronary sinus (CS), and esophagus were semiautomatically segmented. Segmentation quality was assessed from 1 (poor) to 4 (excellent). The reconstructed structures were registered with the electroanatomic map (EAM). PVI was performed using the registered 3D images. RESULTS: Semiautomatic reconstruction of the heart chambers was successfully performed in all 80 patients with AF. CE-CT DICOM file import, semiautomatic segmentation of cardiac chambers, esophagus, and CS was performed in 185 ± 105, 18 ± 5, 119 ± 47, and 69 ± 19 seconds, respectively. Average segmentation quality was 3.9 ± 0.2, 3.8 ± 0.3, and 3.8 ± 0.2 for LA, esophagus, and CS, respectively. Registration accuracy between the EAM and CE-CT-derived segmentation was 4.2 ± 0.9 mm. Complications consisted of one perforation (1%) which required pericardiocentesis, one increased pericardial effusion treated conservatively (1%), and one early termination of ablation due to thrombus formation on the ablation sheath without TIA/stroke (1%). All targeted PVs (n  =  309) were successfully isolated. CONCLUSIONS: The novel CT- CARTOSEG™ CT Segmentation Module enables a rapid and reliable semiautomatic 3D reconstruction of cardiac chambers and adjacent anatomy, which facilitates successful and safe PVI.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter , Venas Pulmonares/cirugía , Validación de Programas de Computación , Tomografía Computarizada por Rayos X , Medios de Contraste , Ecocardiografía Transesofágica , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pericardiocentesis , Estudios Prospectivos , Ondas de Radio , Interpretación de Imagen Radiográfica Asistida por Computador
11.
Curr Cardiol Rep ; 18(2): 19, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26783000

RESUMEN

Due to an increase in the number of patients with heart failure and ventricular arrhythmias, ventricular tachycardia ablation has a growing clinical role. Long-term success rates remain suboptimal and require creating a detailed electroanatomic map during the procedure to identify fibrotic areas responsible for arrhythmias. Nuclear imaging can identify areas of abnormal myocardial perfusion, metabolism, and innervation, which all may enhance our ability to identify ablation targets, thus decreasing procedure time and improving success rates. Myocardial scar, as assessed by single-photon emission computed tomography (SPECT) perfusion imaging, has been shown to correlate with abnormal areas found during electroanatomic mapping. Abnormal metabolism as identified by (18)fluorodeoxyglucose-positron-emission tomography (PET) imaging has been shown to predict successful ablation sites and help correct errors made in the creation of the electroanatomic map. Abnormal cardiac sympathetic innervation can be identified using the purpose (123)I-meta-iodobenzylguanidine SPECT imaging, which may help in identifying triggers that initiate ventricular tachycardia and also predict successful ablation sites within an otherwise normal myocardium. In conclusion, these imaging modalities can not only offer new insights into the pathophysiology of ventricular arrhythmias but also have the potential to improve outcomes from ventricular tachycardia ablation procedures.


Asunto(s)
Ablación por Catéter , Insuficiencia Cardíaca/prevención & control , Tomografía de Emisión de Positrones , Radiofármacos/administración & dosificación , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Tomografía Computarizada de Emisión de Fotón Único , Ablación por Catéter/métodos , Fluorodesoxiglucosa F18/administración & dosificación , Guanidinas/administración & dosificación , Insuficiencia Cardíaca/fisiopatología , Humanos , Radioisótopos de Yodo/administración & dosificación , Guías de Práctica Clínica como Asunto , Pronóstico , Taquicardia Ventricular/fisiopatología , Tomografía Computarizada de Emisión de Fotón Único/métodos
14.
J Cardiovasc Electrophysiol ; 25(2): 171-6, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24433308

RESUMEN

OBJECTIVES: The objectives of this study were to identify the predictors of life-threatening ventricular arrhythmias in patients with cardiac sarcoidosis (CS) and to evaluate the role of the implantable cardioverter-defibrillator (ICD) in this patient population. BACKGROUND: ICD implantation is a class IIA recommendation for patients with CS. However, some indications for ICD implantation in CS patients are still unclear and not enough data are available to establish predictors of malignant ventricular tachyarrhythmias in this group of patients. METHODS: We retrospectively identified all consecutive patients who were diagnosed with CS, during the period from March 2002 to April 2010. Cardiac rhythm devices were regularly interrogated and clinical data recorded during follow-up visits. RESULTS: Thirty-three patients (17 male) with CS were identified. The mean age was 53 ± 11. The mean left ventricular ejection fraction (LVEF) was 41 ± 18%. Thirty patients received an ICD. Twelve patients (36.3%) had sustained ventricular arrhythmias. Eleven patients received appropriate therapies and 9 patients received inappropriate shocks, representing 36.7% and 30.0% of the ICD population, respectively. Patients who received appropriate ICD therapies were younger with mean age 47.4 ± 7.8, and had a lower mean LVEF 33.0 ± 12.0 compared to those who did not receive ICD therapies (P = 0.0301 and 0.0341, respectively). There were no other demographic, clinical, electrocardiographic, electrophysiological, or imaging markers that predicted the future occurrence of appropriate ICD therapies in our cohort of patients. CONCLUSIONS: CS is strongly associated with malignant ventricular arrhythmias. No specific predictors of such tachyarrhythmias emerged, other than young age and low LVEF.


Asunto(s)
Cardiomiopatías/terapia , Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas/métodos , Sarcoidosis/terapia , Taquicardia Ventricular/terapia , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Pronóstico , Reproducibilidad de los Resultados , Sarcoidosis/complicaciones , Sarcoidosis/diagnóstico , Sensibilidad y Especificidad , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Resultado del Tratamiento
16.
Pacing Clin Electrophysiol ; 37(10): 1274-83, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24766563

RESUMEN

BACKGROUND: Cardiac magnetic resonance imaging (CMRI) is the gold standard for myocardial scar evaluation. Although ideal for substrate assessment in ventricular tachycardia (VT), most patients have an implantable cardioverter-defibrillator (ICD) at presentation for ablation. This study evaluates the ICD artifact burden during standard late gadolinium enhancement CMRI (LGE-CMRI) evaluation of myocardial scar in VT patients with ICDs. METHODS: Thirty-one patients with ICD and cardiomyopathy underwent LGE-CMRI using 1.5-T magnetic resonance scanner before VT ablation. Using the American Heart Association (AHA) 17-segment model, short-axis LGE series were analyzed for artifact burden localization and assessment. RESULTS: Preablation CMRI was performed in 31 patients with single chamber (n = 13), dual chamber (n = 11), and biventricular (n = 7) ICDs. Pre- and post-MRI ICD parameters were unchanged. All patients had susceptibility artifact and 51.6% (256 of 496) of segments were affected by artifact. The artifact area (178 ± 136 cm(2) ) resulted in an artifact burden of 54 ± 21% of the LV myocardial area (327 ± 15 cm(2) ). The anterior wall was most affected by artifact (89%) compared with 52%, 49%, and 23% in the lateral, septal, and inferior walls, respectively (P < 0.0001). The apical segments had more artifact burden (66%) than the mid (49%) and basal (44%) segments (P = 0.0005). Artifact area correlated with ICD-heart distance on anteroposterior chest radiograph (r = 0.42, P = 0.021) and body mass index (r = -0.48, P = 0.008). CONCLUSIONS: Current clinical LGE-CMRI scar imaging protocols produce ICD artifacts that affect >50% of the LV myocardium and correlate with the ICD-heart distance. This significantly limits the application of CMRI for image-guided VT ablation.


Asunto(s)
Artefactos , Técnicas de Imagen Cardíaca , Ablación por Catéter , Desfibriladores Implantables , Gadolinio , Imagen por Resonancia Magnética , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Femenino , Humanos , Aumento de la Imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
17.
Pacing Clin Electrophysiol ; 37(4): 412-21, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24164545

RESUMEN

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used to guide complex ablation procedures. This study aimed to assess the scar substrate of ventricular tachycardia (VT) by ICE in patients undergoing VT ablation. METHODS: In 22 patients undergoing VT ablation (10 ischemic, 12 nonischemic), the Biosense CARTOSOUND module (Biosense Webster, Diamond Bar, CA, USA) was used for three-dimensional reconstruction of the ventricles. The characteristics and appearance with ICE imaging of voltage-defined scar zones (bipolar voltage <0.5 mV), border zones (0.5-1.5 mV), and normal myocardium (>1.5 mV) on electroanatomic maps were evaluated. The standard image analysis software Image J (National Institutes of Health, Bethesda, MD, USA) was used to analyze signal intensity (mean pixel signal intensity unit [SIU]) and heterogeneity (standard deviation of signal intensity in analyzed area) on ICE images. RESULTS: A total of 83 myocardial areas were analyzed from two-dimensional ICE images (15 scars, 31 border zones, and 37 normal). Voltage-defined scar zones had increased signal intensities compared to border zones (149 SIU vs 104 SIU, P < 0.0001) and normal myocardium (88 SIU, P < 0.0001). Border zones were more likely to have heterogeneous densities compared to normal myocardium (standard deviation of signal intensity 20 SIU vs 12 SIU, P < 0.0001). In receiver-operator characteristic analyses, signal intensity ≥ 137 SIU differentiated scar from nonscar zones (area under curve 0.91, P < 0.0001). Software-based color enhancement of areas with signal intensity ≥ 137 SIU allowed identification of the VT substrate in all 15 patients with voltage-defined scar zones. CONCLUSIONS: ICE provides important information about the VT anatomical substrate and may have potential to identify areas of scarred myocardium.


Asunto(s)
Cateterismo Cardíaco/métodos , Ablación por Catéter/métodos , Cicatriz/diagnóstico por imagen , Cirugía Asistida por Computador/métodos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Cicatriz/complicaciones , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Ventricular/complicaciones , Resultado del Tratamiento
18.
Pacing Clin Electrophysiol ; 37(2): 157-63, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24102109

RESUMEN

INTRODUCTION: During mapping and ablation procedures, the movement of large ferromagnetic items (i.e., fluoroscopic equipment) introduce heterogeneities in the electromagnetic field, which may affect the accuracy of electromagnet-based navigation. We aimed to assess the impact of common periprocedural fluoroscopic equipment movement on the accuracy of an electromagnet-based navigation system. METHODS AND RESULTS: The impact of fluoroscopic equipment movement on the accuracy of the Carto® 3 System (Biosense Webster, Inc., Diamond Bar, CA, USA) was assessed both in vitro (n = 20 patients, phantom model) and in vivo (n = 18 patients). Location recordings were obtained with unchanged catheter position for fluoroscopic equipment rotational movements (RMs) and maximal to closest distance (MD to CD) to phantom/patient. The effects of both single- and biplane fluoroscopy were assessed. In vitro, the movement of fluoroscopic equipment resulted in an average catheter location estimation error of 0.8 mm (interquartile range 0.3-1.3). The maximal location estimation errors with MD to CD movement and RM were 2.3 mm and 1.3 mm, respectively. Changing from single-plane to biplane setup resulted in an average location estimation change of 1.5 mm (maximum 2.1). Larger location changes were observed in vivo (2.9 mm vs 0.8 mm, P < 0.0001) with 28.7% of these exceeded 4 mm versus none of the in vitro measurements (P < 0.0001). CONCLUSION: Although fluoroscopy manipulation affected the accuracy of the Carto® 3 System, the in vitro data suggest that these inaccuracies are likely of limited clinical consequences. The larger in vivo inaccuracies are most likely due to nonferromagnetic interferences, such as respiratory or cardiac movements.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Mapeo del Potencial de Superficie Corporal/instrumentación , Fluoroscopía/instrumentación , Imagenología Tridimensional/instrumentación , Imanes , Imagen Multimodal/instrumentación , Mapeo del Potencial de Superficie Corporal/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Fluoroscopía/métodos , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Cureus ; 16(7): e64476, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39135814

RESUMEN

Cardiomyopathy is defined as structural and functional myocardial abnormality not attributed to ischemic, valvular, hypertensive, or congenital cardiac causes. The main phenotypes of cardiomyopathy include hypertrophic, dilated, non-dilated left ventricular, restrictive, arrhythmogenic right ventricular, Takotsubo, and left ventricular noncompaction cardiomyopathies. A significant proportion of dilated cardiomyopathy (DCM) cases represents patients with genetic mutations, most commonly titin gene truncating variants (TTNtv). It has been shown that TTNtv mutation contributes to the development of certain types of DCM such as alcohol, chemotherapy, and peripartum. We present a case of DCM where genetic workup revealed TTNtv without other contributing factors. The course was complicated by multiple ventricular tachycardias (VTs) refractory to medical management, despite treatment with amiodarone, sotalol, dofetilide, mexiletine, and propranolol. Interestingly, endocardial mapping failed to delineate the substrate of tachycardia. This report underscores the importance of genetic testing in DCM and highlights the potential association of titin cardiomyopathy with refractory VTs, possibly of epicardial origin.

20.
Heart Rhythm ; 21(8): 1289-1295, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38641221

RESUMEN

BACKGROUND: Premature ventricular contraction (PVC) burden is a risk factor for heart failure and cardiovascular death in patients with structural heart disease. Long-term electrocardiographic monitoring can have a significant impact on PVC burden evaluation by further defining PVC distribution patterns. OBJECTIVE: This study aimed to ascertain the optimal duration of electrocardiographic monitoring to characterize PVC burden and to understand clinical characteristics associated with frequent PVCs and nonsustained ventricular tachycardia in a large US cohort. METHODS: Commercial data (iRhythm's Zio patch) from June 2011 to April 2022 were analyzed. Inclusion criteria were age >18 years, PVC burden ≥5%, and wear period ≥13 days. PVC burden cutoffs were determined on the basis of AHA/ACC/HRS guidelines for very frequent PVCs (10,000-20,000 during 24 hours). Patients were assigned to categories by PVC densities: low, <10%; moderate, 10% to <20%; and high, ≥20%. Mean measured error was assessed at baseline and daily until the wear period's end for overall PVC burden and different PVC densities. RESULTS: Analysis of 106,705 patch monitors revealed a study population with mean age of 70.6 ± 14.6 years (33.6% female). PVC burden was higher in male patients and those >65 years of age. PVC burden mean error decreased from 2.9% at 24 hours to 1.3% at 7 days and 0.7% at 10 days. Number of ventricular tachycardia episodes per patient increased with increasing PVC burden (P < .0001). CONCLUSION: Extending ambulatory monitoring beyond 24 hours to 7 days or more improves accuracy of assessing PVC burden. Ventricular tachycardia frequency and duration vary by initial PVC density, highlighting the need for prolonged cardiac monitoring.


Asunto(s)
Electrocardiografía Ambulatoria , Complejos Prematuros Ventriculares , Humanos , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/epidemiología , Masculino , Femenino , Anciano , Electrocardiografía Ambulatoria/métodos , Estados Unidos/epidemiología , Estudios Retrospectivos , Factores de Tiempo , Persona de Mediana Edad , Estudios de Seguimiento , Electrocardiografía/métodos , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA