Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Surg (Torino) ; 65(2): 99-105, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38551514

RESUMEN

The initial success and widespread adoption of endovascular aneurysm repair (EVAR) for the treatment of abdominal aortic aneurysms have been tempered by numerous reports of secondary interventions and increased long-term mortality compared with open repair. Over the past decade, several studies on postoperative sac dynamics after EVAR have suggested that the presence of sac regression is a benign feature with a favorable prognosis. Conversely, increasing sacs and even stable sacs can be indicators of more unstable sac behavior with worse outcomes in the long-term. Endoleaks were initially perceived as the main drivers of sac behavior. However, the observation that sac regression can occur in the presence of endoleaks, and vice versa - increasing sacs without evidence of endoleak - on imaging studies, suggests the involvement of other contributing factors. These factors can be divided into anatomical factors, patient characteristics, sac thrombus composition, and device-related factors. The shift of interest away from especially type 2 endoleaks is further supported by promising results with the use of EndoAnchors regarding postoperative sac behavior. This review provides an overview of the existing literature on the implications and known risk factors of post-EVAR sac behavior, describes the accurate measurement of sac behavior, and discusses the use of EndoAnchors to promote sac regression.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Endofuga , Procedimientos Endovasculares , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Endofuga/etiología , Factores de Riesgo , Resultado del Tratamiento , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Diseño de Prótesis
2.
J Cardiovasc Surg (Torino) ; 64(2): 134-141, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36987816

RESUMEN

BACKGROUND: For descending thoracic aortic aneurysms (TAA) in proximity of the aortic arch, debranching of the left subclavian artery (LSA) may be necessary to extend proximal sealing in zone 2. The aim of this study was to determine the added proximal apposition length gained from LSA debranching during thoracic endovascular aortic repair (TEVAR). METHODS: This multicenter retrospective study (2010-2020) included patients who underwent elective TEVAR in zone 2 for a degenerative TAA where the LSA was surgically debranched. The endograft position on the first postoperative computed tomography angiography (CTA) scan was assessed using post-processing software. The analysis included the shortest apposition length (SAL), the tilt of the proximal edge of the endograft, and the distance between the endograft and the left common carotid artery. Clinical endpoints (neurological complications and endoleaks) at 30 days were also reported. RESULTS: Twenty-two patients were included. The median interval between TEVAR and the first postoperative CTA was 3 days (2-10 days). Median SAL was 9.2 mm (1.3-26.4 mm), of which 8.6 mm (1.3-16.2 mm) was gained proximal of the LSA, including the LSA orifice. In 12 patients (55.5%) the SAL was <10 mm. The median tilt was 18.3° (13.9°-22.2°). Seven endoleaks were reported on the first CTA: 1 type Ia, 2 type Ib, 3 type II, and 1 type III. CONCLUSIONS: Debranching the LSA adds valuable sealing length in zone 2, but the SAL was still relatively short in many patients, putting these patients at risk for a future type Ia endoleak. Accurate assessment of the circumferential apposition on postoperative CTA follow-up in these high-risk patients with short, complex landing zones seems mandatory. Evaluation of apposition in a larger population with longer follow-up is advised.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Reparación Endovascular de Aneurismas , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/cirugía , Arteria Subclavia/diagnóstico por imagen , Arteria Subclavia/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Aortografía/métodos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA