RESUMEN
PURPOSE: The aim of this study was to evaluate interobserver agreement (IOA) on target volume definition for pancreatic cancer (PACA) within the Radiosurgery and Stereotactic Radiotherapy Working Group of the German Society of Radiation Oncology (DEGRO) and to identify the influence of imaging modalities on the definition of the target volumes. METHODS: Two cases of locally advanced PACA and one local recurrence were selected from a large SBRT database. Delineation was based on either a planning 4D CT with or without (w/wo) IV contrast, w/wo PET/CT, and w/wo diagnostic MRI. Novel compared to other studies, a combination of four metrics was used to integrate several aspects of target volume segmentation: the Dice coefficient (DSC), the Hausdorff distance (HD), the probabilistic distance (PBD), and the volumetric similarity (VS). RESULTS: For all three GTVs, the median DSC was 0.75 (range 0.17-0.95), the median HD 15 (range 3.22-67.11) mm, the median PBD 0.33 (range 0.06-4.86), and the median VS was 0.88 (range 0.31-1). For ITVs and PTVs the results were similar. When comparing the imaging modalities for delineation, the best agreement for the GTV was achieved using PET/CT, and for the ITV and PTV using 4D PET/CT, in treatment position with abdominal compression. CONCLUSION: Overall, there was good GTV agreement (DSC). Combined metrics appeared to allow a more valid detection of interobserver variation. For SBRT, either 4D PET/CT or 3D PET/CT in treatment position with abdominal compression leads to better agreement and should be considered as a very useful imaging modality for the definition of treatment volumes in pancreatic SBRT. Contouring does not appear to be the weakest link in the treatment planning chain of SBRT for PACA.
Asunto(s)
Adenocarcinoma , Neoplasias Pulmonares , Neoplasias Pancreáticas , Radiocirugia , Humanos , Radiocirugia/métodos , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/radioterapia , Adenocarcinoma/cirugía , Tomografía Computarizada por Tomografía de Emisión de Positrones , Variaciones Dependientes del Observador , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/cirugía , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias PancreáticasRESUMEN
BACKGROUND: In radical radiochemotherapy (RCT) of inoperable non-small-cell lung cancer (NSCLC) typical prognostic factors include T- and N-stage, while there are still conflicting data on the prognostic relevance of gross tumor volume (GTV) and particularly its changes during RCT. The NCT03055715 study of the Young DEGRO working group of the German Society of Radiation Oncology (DEGRO) evaluated the prognostic impact of GTV and its changes during RCT. METHODS: A total of 21 university centers for radiation oncology from five different European countries (Germany, Switzerland, Spain, Belgium, and Austria) participated in the study which evaluated nâ¯= 347 patients with confirmed (biopsy) inoperable NSCLC in UICC stage III A/B who received radical curative-intent RCT between 2010 and 2013. Patient and disease data were collected anonymously via electronic case report forms and entered into the multi-institutional RadPlanBio platform for central data analysis. GTV before RCT (initial planning CT, GTV1) and at 40-50â¯Gy (re-planning CT for radiation boost, GTV2) was delineated. Absolute GTV before/during RCT and relative GTV changes were correlated with overall survival as the primary endpoint. Hazard ratios (HR) of survival analysis were estimated by means of adjusted Cox regression models. RESULTS: GTV1 was found to have a mean of 154.4â¯ml (95%CI: 1.5-877) and GTV2 of 106.2â¯ml (95% CI: 0.5-589.5), resulting in an estimated reduction of 48.2â¯ml (pâ¯< 0.001). Median overall survival (OS) was 18.8 months with a median of 22.1, 20.9, and 12.6 months for patients with high, intermediate, and low GTV before RT. Considering all patients, in one survival model of overall mortality, GTV2 (2.75 (1.12-6.75, pâ¯= 0.03) was found to be a stronger survival predictor than GTV1 (1.34 (0.9-2, pâ¯> 0.05). In patients with available data on both GTV1 and GTV2, absolute GTV1 before RT was not significantly associated with survival (HR 0-69, 0.32-1.49, pâ¯> 0.05) but GTV2 significantly predicted OS in a model adjusted for age, T stage, and chemotherapy, with an HR of 3.7 (1.01-13.53, pâ¯= 0.04) per 300â¯ml. The absolute decrease from GTV1 to GTV2 was correlated to survival, where every decrease by 50â¯ml reduced the HR by 0.8 (CI 0.64-0.99, pâ¯= 0.04). There was no evidence for a survival effect of the relative change between GTV1 and GTV2. CONCLUSION: Our results indicate that independently of T stage, the re-planning GTV during RCT is a significant and superior survival predictor compared to baseline GTV before RT. Patients with a high absolute (rather than relative) change in GTV during RT show a superior survival outcome after RCT.
Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/terapia , Quimioradioterapia , Neoplasias Pulmonares/terapia , Carga Tumoral , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/patología , Estudios de Cohortes , Europa (Continente) , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Pronóstico , Modelos de Riesgos Proporcionales , Dosificación Radioterapéutica , Estudios Retrospectivos , Resultado del Tratamiento , Carga Tumoral/efectos de la radiaciónRESUMEN
BACKGROUND AND PURPOSE: Recently, imaging and high-precision irradiation devices for preclinical tumor models have been developed. Image-guided radiation therapy (IGRT) including innovative treatment planning techniques comparable to patient treatment can be achieved in a translational context. The study aims to evaluate magnetic resonance imaging/computed tomography (MRI/CT)-based treatment planning with different treatment techniques for high-precision radiation therapy (RT). MATERIALS AND METHODS: In an orthotopic pancreatic cancer model, MRI/CT-based radiation treatment planning was established. Three irradiation techniques (rotational, 3D multifield, stereotactic) were performed with the SARRP system (Small Animal Radiation Research Platform, Xstrahl Ltd., Camberley, UK). Dose distributions in gross tumor volume (GTV) and organs at risk (OAR) were analyzed for each treatment setting. RESULTS: MRI with high soft tissue contrast improved imaging of GTV and OARs. Therefore MRI-based treatment planning enables precise contouring of GTV and OARs, thus, providing a perfect basis for an improved dose distribution and coverage of the GTV for all advanced radiation techniques. CONCLUSION: An MRI/CT-based treatment planning for high-precision IGRT using different techniques was established in an orthotopic pancreatic tumor model. Advanced radiation techniques allow considering perfect coverage of GTV and sparing of OARs in the preclinical setting and reflect clinical treatment plans of pancreatic cancer patients.
Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias Experimentales/radioterapia , Neoplasias Pancreáticas/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Animales , Línea Celular Tumoral , Ratones , Ratones Desnudos , Trasplante de Neoplasias , Investigación Biomédica TraslacionalRESUMEN
BACKGROUND AND PURPOSE: High-precision radiotherapy (RT) requires precise positioning, particularly with high single doses. Fiducial markers in combination with onboard imaging are excellent tools to support this. The purpose of this study is to establish a pancreatic cancer mouse model for high-precision image-guided RT (IGRT) using the liquid fiducial marker BioXmark (Nanovi, Kongens Lyngby, Denmark). METHODS: In an animal-based cancer model, different volumes of BioXmark (10-50 µl), application forms, and imaging modalities-cone-beam computer tomography (CBCT) incorporated in either the Small Animal Radiation Research Platform (SARRP) or the small-animal micro-CT Scanner (SkyScan; Bruker, Brussels, Belgium)-as well as subsequent RT with the SARRP system were analyzed to derive recommendations for BioXmark. RESULTS: Even small volumes (10 µl) of BioXmark could be detected by CBCT (SARRP and Skyscan). Larger volumes (50 µl) led to hardening artefacts. The position of BioXmark was monitored at least weekly by CBCT and was stable over 4 months. BioXmark was shown to be well tolerated; no changes in physical condition or toxic side effects were observed in comparison to control mice. BioXmark enabled an exact fusion with the original treatment plan with less hardening artefacts, and minimized the application of contrast agent for fractionated RT. CONCLUSION: An orthotopic pancreatic tumor mouse model was established for high-precision IGRT using a fiducial marker. BioXmark was successfully tested and provides the perfect basis for improved imaging in high-precision RT. BioXmark enables a unique application method and optimal targeted precision in fractionated RT. Therefore, preclinical trials evaluating novel fractionation regimens and/or combination treatment with high-end RT can be performed.
Asunto(s)
Tomografía Computarizada de Haz Cónico/instrumentación , Marcadores Fiduciales , Aumento de la Imagen/instrumentación , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/radioterapia , Radioterapia Guiada por Imagen/instrumentación , Animales , Línea Celular Tumoral , Humanos , Ratones , Ratones Desnudos , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Soluciones , Resultado del TratamientoRESUMEN
Highly aggressive cancer types such as pancreatic cancer possess a mortality rate of up to 80% within the first 6months after diagnosis. To reduce this high mortality rate, more sensitive diagnostic tools allowing an early stage medical imaging of even very small tumours are needed. For this purpose, magnetic, biodegradable nanoparticles prepared using recombinant human serum albumin (rHSA) and incorporated iron oxide (maghemite, γ-Fe2O3) nanoparticles were developed. Galectin-1 has been chosen as target receptor as this protein is upregulated in pancreatic cancer and its precursor lesions but not in healthy pancreatic tissue nor in pancreatitis. Tissue plasminogen activator derived peptides (t-PA-ligands), that have a high affinity to galectin-1 have been chosen as target moieties and were covalently attached onto the nanoparticle surface. Improved targeting and imaging properties were shown in mice using single photon emission computed tomography-computer tomography (SPECT-CT), a handheld gamma camera, and magnetic resonance imaging (MRI).