Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 151
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(3): 615-623, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36748854

RESUMEN

INTRODUCTION: Idiopathic ventricular fibrillation (IVF) is mainly associated with and triggered by short-coupled (R-on-T) ventricular ectopics. However, little is known about the risk of VF associated with long-coupled premature ventricular complexes (LCPVCs). OBJECTIVE: To examine the prevalence and characteristics of IVF patients presenting with LCPVCs. METHODS: Consecutive patients with IVF and PVCs from five arrhythmia referral centers were reviewed. We included patients presenting LCPVCs, defined as PVCs falling after the end of the T wave, with a normal QTc interval. We evaluated demographics, medical history, and clinical circumstances associated with PVCs and VF episodes. The origin of PVCs was determined by invasive mapping. RESULTS: Seventy-nine patients with IVF were reviewed. Among them, 12 (15.2%) met the inclusion criteria (8 women, age 36 ± 14 years). Eleven patients had documented LCPVCs initiating repetitive PVCs or sustained VF, whereas 1 had only documented isolated PVCs. In 10 of 12 patients, PVCs were recorded showing both long and short coupling intervals of 418 ± 46 and 304 ± 33 ms, respectively. Mapping showed that PVCs originated from the left Purkinje in 10 patients, from the right Purkinje in 1 patient, and both in 1 patient. Compared to other patients from the initial cohort, IVF with LCPVCs was associated with a left-sided origin of PVCs (92% in long-coupled IVF vs. 46% of left Purkinje PVCs in short-coupled IVF, p = .004). CONCLUSION: Long-coupled fascicular PVCs, traditionally recognized as benign, can be associated with IVF in a subset of patients. They can induce IVF by themselves or in association with short-coupled PVCs.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares , Humanos , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Fibrilación Ventricular
2.
J Cardiovasc Electrophysiol ; 34(8): 1708-1717, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37431258

RESUMEN

BACKGROUND: The impact of filtering on bipolar electrograms (EGMs) has not been systematically examined. We tried to clarify the optimal filter configuration for ventricular tachycardia (VT) ablation. METHODS: Fifteen patients with VT were included. Eight different filter configurations were prospectively created for the distal bipoles of the ablation catheter: 1.0-250, 10-250, 100-250, 30-50, 30-100, 30-250, 30-500, and 30-1000 Hz. Pre-ablation stable EGMs with good contact (contact force > 10 g) were analyzed. Baseline fluctuation, baseline noise, bipolar peak-to-peak voltage, and presence of local abnormal ventricular activity (LAVA) were compared between different filter configurations. RESULTS: In total, 2276 EGMs with multiple bipolar configurations in 246 sites in scar and border areas were analyzed. Baseline fluctuation was only observed in the high-pass filter of (HPF) ≤ 10 Hz (p < .001). Noise level was lowest at 30-50 Hz (0.018 [0.012-0.029] mV), increased as the low-pass filter (LPF) extended, and was highest at 30-1000 Hz (0.047 [0.041-0.061] mV) (p < .001). Conversely, the HPF did not affect the noise level at ≤30 Hz. As the HPF extended to 100 Hz, bipolar voltages significantly decreased (p < .001), but were not affected when the LPF was extended to ≥100 Hz. LAVAs were most frequently detected at 30-250 Hz (207/246; 84.2%) and 30-500 Hz (208/246; 84.6%), followed by 30-1000 Hz (205/246; 83.3%), but frequently missed at LPF ≤ 100 Hz or HPF ≤ 10 Hz (p < .001). A 50-Hz notch-filter reduced the bipolar voltage by 43.9% and LAVA-detection by 34.5% (p < .0001). CONCLUSION: Bipolar EGMs are strongly affected by filter settings in scar/border areas. In all, 30-250 or 30-500 Hz may be the best configuration, minimizing the baseline fluctuation, baseline noise, and detecting LAVAs. Not applying the 50-Hz notch filter may be beneficial to avoid missing VT substrate.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Cicatriz , Ablación por Catéter/efectos adversos
3.
J Cardiovasc Electrophysiol ; 34(6): 1395-1404, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37232426

RESUMEN

AIM: Ventricular arrhythmias (VAs) are the most common cause of death in patients with repaired Tetralogy of Fallot (rTOF). However, risk stratifying remains challenging. We examined outcomes following programmed ventricular stimulation (PVS) with or without subsequent ablation in patients with rTOF planned for pulmonary valve replacement (PVR). METHODS: We included all consecutive patients with rTOF referred to our institution from 2010 to 2018 aged ≥18 years for PVR. Right ventricular (RV) voltage maps were acquired and PVS was performed from two different sites at baseline, and if non-inducible under isoproterenol. Catheter and/or surgical ablation was performed when patients were inducible or when slow conduction was present in anatomical isthmuses (AIs). Postablation PVS was undertaken to guide implantable cardioverter-defibrillator (ICD) implantation. RESULTS: Seventy-seven patients (36.2 ± 14.3 years old, 71% male) were included. Eighteen were inducible. In 28 patients (17 inducible, 11 non-inducible but with slow conduction) ablation was performed. Five had catheter ablation, surgical cryoablation in 9, both techniques in 14. ICDs were implanted in five patients. During a follow-up of 74 ± 40 months, no sudden cardiac death occurred. Three patients experienced sustained VAs, all were inducible during the initial EP study. Two of them had an ICD (low ejection fraction for one and important risk factor for arrhythmia for the second). No VAs were reported in the non-inducible group (p < .001). CONCLUSION: Preoperative EPS can help identifying patients with rTOF at risk for VAs, providing an opportunity for targeted ablation and may improve decision-making regarding ICD implantation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Válvula Pulmonar , Taquicardia Ventricular , Tetralogía de Fallot , Humanos , Masculino , Adolescente , Adulto , Adulto Joven , Persona de Mediana Edad , Femenino , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Tetralogía de Fallot/complicaciones , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía
4.
J Cardiovasc Magn Reson ; 25(1): 78, 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38093273

RESUMEN

BACKGROUND: While the microstructure of the left ventricle (LV) has been largely described, only a few studies investigated the right ventricular insertion point (RVIP). It was accepted that the aggregate cardiomyocytes organization was much more complex due to the intersection of the ventricular cavities but a precise structural characterization in the human heart was lacking even if clinical phenotypes related to right ventricular wall stress or arrhythmia were observed in this region. METHODS: MRI-derived anatomical imaging (150 µm3) and diffusion tensor imaging (600 µm3) were performed in large mammalian whole hearts (human: N = 5, sheep: N = 5). Fractional anisotropy, aggregate cardiomyocytes orientations and tractography were compared within both species. Aggregate cardiomyocytes orientation on one ex-vivo sheep whole heart was then computed using structure tensor imaging (STI) from 21 µm isotropic acquisition acquired with micro computed tomography (MicroCT) imaging. Macroscopic and histological examination were performed. Lastly, experimental cardiomyocytes orientation distribution was then compared to the usual rule-based model using electrophysiological (EP) modeling. Electrical activity was modeled with the monodomain formulation. RESULTS: The RVIP at the level of the inferior ventricular septum presented a unique arrangement of aggregate cardiomyocytes. An abrupt, mid-myocardial change in cardiomyocytes orientation was observed, delimiting a triangle-shaped region, present in both sheep and human hearts. FA's histogram distribution (mean ± std: 0.29 ± 0.06) of the identified region as well as the main dimension (22.2 mm ± 5.6 mm) was found homogeneous across samples and species. Averaged volume is 0.34 cm3 ± 0.15 cm3. Both local activation time (LAT) and morphology of pseudo-ECGs were strongly impacted with delayed LAT and change in peak-to-peak amplitude in the simulated wedge model. CONCLUSION: The study was the first to describe the 3D cardiomyocytes architecture of the basal inferoseptal left ventricle region in human hearts and identify the presence of a well-organized aggregate cardiomyocytes arrangement and cardiac structural discontinuities. The results might offer a better appreciation of clinical phenotypes like RVIP-late gadolinium enhancement or uncommon idiopathic ventricular arrhythmias (VA) originating from this region.


Asunto(s)
Imagen de Difusión Tensora , Ventrículos Cardíacos , Humanos , Animales , Ovinos , Ventrículos Cardíacos/diagnóstico por imagen , Imagen de Difusión Tensora/métodos , Medios de Contraste , Microtomografía por Rayos X , Valor Predictivo de las Pruebas , Gadolinio , Miocitos Cardíacos/fisiología , Arritmias Cardíacas , Mamíferos
5.
Europace ; 25(2): 331-340, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36107465

RESUMEN

AIMS: Climate change represents the biggest global health threat of the 21st century. Health care system is itself a large contributor to greenhouse gas (GHG) emissions. In cardiology, atrial fibrillation (AF) catheter ablation is an increasing activity using numerous non-reusable materials that could contribute to GHG emission. Determining a detailed carbon footprint analysis of an AF catheter ablation procedure allows the identification of the main polluting sources that give opportunities for reduction of environmental impact. To assess the carbon footprint of AF catheter ablation procedure. To determine priority actions to decrease pollution. METHODS AND RESULTS: An eco-audit method used to predict the GHG emission of an AF catheter ablation procedure was investigated. Two workstations were considered including surgery and anaesthesia. In the operating room, every waste produced by single-use medical devices, pharmaceutical drugs, and energy consumption during intervention were evaluated. All analyses were limited to the operating room. Thirty procedures were analysed over a period of 8 weeks: 18 pulmonary veins isolation RF ablations, 7 complex RF procedures including PVI, roof and mitral isthmus lines, ethanol infusion of the Marshall vein and cavo tricuspid isthmus line, and 5 pulmonary vein isolation with cryoballoon. The mean emission during AF catheter ablation procedures was 76.9 kg of carbon dioxide equivalent (CO2-e). The operating field accounted for 75.4% of the carbon footprint, while only 24.6% for the anaesthesia workstation. On one hand, material production and manufacturing were the most polluting phases of product life cycle which, respectively, represented 71.3% (54.8 kg of CO2-e) and 17.0% (13.1 kg of CO2-e) of total pollution. On the other hand, transport contributed in 10.6% (8.1 kg of CO2-e), while product use resulted in 1.1% (0.9 kg of CO2-e) of GHG production. Electrophysiology catheters were demonstrated to be the main contributors of environmental impact with 29.9 kg of CO2-e (i.e. 38.8%). Three dimensional mapping system and electrocardiogram patches were accounting for 6.8 kg of CO2-e (i.e. 8.8% of total). CONCLUSION: AF catheter ablation involves a mean of 76.9 kg of CO2-e. With an estimated 600 000 annual worldwide procedures, the environmental impact of AF catheter ablation activity is estimated equal to 125 tons of CO2 emission each day. It represents an equivalent of 700 000 km of car ride every day. Electrophysiology catheters and patches are the main contributors of the carbon footprint. The focus must be on reducing, reusing, and recycling these items to limit the impact of AF ablation on the environment. A road map of steps to implement in different time frames is proposed.


Asunto(s)
Técnicas de Ablación , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Huella de Carbono , Dióxido de Carbono , Venas Pulmonares/cirugía , Ablación por Catéter/métodos , Resultado del Tratamiento
6.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37428890

RESUMEN

AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24 ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Humanos , Estudios Retrospectivos , Técnicas Electrofisiológicas Cardíacas , Taquicardia , Atrios Cardíacos , Resultado del Tratamiento
7.
Europace ; 25(2): 487-495, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36355748

RESUMEN

AIMS: Assess prevalence, risk factors, and management of patients with intra-cardiac thrombus referred for scar-related ventricular tachycardia (VT) ablation. METHODS AND RESULTS: Consecutive VT ablation referrals between January 2015 and December 2019 were reviewed (n = 618). Patients referred for de novo, scar-related VT ablation who underwent pre-procedure cardiac computed tomography (cCT) were included. We included 401 patients [61 ± 14 years; 364 male; left ventricular ejection fraction (LVEF) 40 ± 13%]; 45 patients (11%) had cardiac thrombi on cCT at 49 sites [29 LV; eight left atrial appendage (LAA); eight right ventricle (RV); four right atrial appendage]. Nine patients had pulmonary emboli. Overall predictors of cardiac thrombus included LV aneurysm [odds ratio (OR): 6.6, 95%, confidence interval (CI): 3.1-14.3], LVEF < 40% (OR: 3.3, CI: 1.5-7.3), altered RV ejection fraction (OR: 2.3, CI: 1.1-4.6), and electrical storm (OR: 2.9, CI: 1.4-6.1). Thrombus location-specific analysis identified LV aneurysm (OR: 10.9, CI: 4.3-27.7) and LVEF < 40% (OR: 9.6, CI: 2.6-35.8) as predictors of LV thrombus and arrhythmogenic right ventricular cardiomyopathy (OR: 10.6, CI: 1.2-98.4) as a predictor for RV thrombus. Left atrial appendage thrombi exclusively occurred in patients with atrial fibrillation. Ventricular tachycardia ablation was finally performed in 363 including 7 (16%) patients with thrombus but refractory electrical storm. These seven patients had tailored ablation with no embolic complications. Only one (0.3%) ablation-related embolic event occurred in the entire cohort. CONCLUSION: Cardiac thrombus can be identified in 11% of patients referred for scar-related VT ablation. These findings underscore the importance of systematic thrombus screening to minimize embolic risk.


Asunto(s)
Ablación por Catéter , Cardiopatías , Taquicardia Ventricular , Trombosis , Humanos , Masculino , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/diagnóstico , Volumen Sistólico , Prevalencia , Cicatriz , Función Ventricular Izquierda , Cardiopatías/diagnóstico por imagen , Cardiopatías/epidemiología , Cardiopatías/complicaciones , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Ablación por Catéter/efectos adversos , Factores de Riesgo , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 46(6): 515-518, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36690018

RESUMEN

The 12-lead electrocardiogram (ECG) is a fundamental modality to help determine the mechanism and the localization of atrial tachycardias (ATs). Although macroreentrant ATs and focal ATs typically show F-waves and discrete P-waves respectively on the 12-lead ECG, this is not universally the case in scar-related ATs.1, We present three cases clearly showing the discrepancy between the AT morphology on the 12-lead ECG and the AT-mechanism.


Asunto(s)
Ablación por Catéter , Taquicardia Atrial Ectópica , Taquicardia Supraventricular , Humanos , Cicatriz , Electrocardiografía
9.
Curr Cardiol Rep ; 25(6): 535-542, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37115434

RESUMEN

PURPOSE OF REVIEW: Imaging plays a crucial role in the therapy of ventricular tachycardia (VT). We offer an overview of the different methods and provide information on their use in a clinical setting. RECENT FINDINGS: The use of imaging in VT has progressed recently. Intracardiac echography facilitates catheter navigation and the targeting of moving intracardiac structures. Integration of pre-procedural CT or MRI allows for targeting the VT substrate, with major expected impact on VT ablation efficacy and efficiency. Advances in computational modeling may further enhance the performance of imaging, giving access to pre-operative simulation of VT. These advances in non-invasive diagnosis are increasingly being coupled with non-invasive approaches for therapy delivery. This review highlights the latest research on the use of imaging in VT procedures. Image-based strategies are progressively shifting from using images as an adjunct tool to electrophysiological techniques, to an integration of imaging as a central element of the treatment strategy.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Arritmias Cardíacas , Corazón , Frecuencia Cardíaca , Ablación por Catéter/métodos , Resultado del Tratamiento
10.
Eur Heart J ; 43(12): 1234-1247, 2022 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-35134898

RESUMEN

AIMS: Mapping data of human ventricular fibrillation (VF) are limited. We performed detailed mapping of the activities underlying the onset of VF and targeted ablation in patients with structural cardiac abnormalities. METHODS AND RESULTS: We evaluated 54 patients (50 ± 16 years) with VF in the setting of ischaemic (n = 15), hypertrophic (n = 8) or dilated cardiomyopathy (n = 12), or Brugada syndrome (n = 19). Ventricular fibrillation was mapped using body-surface mapping to identify driver (reentrant and focal) areas and invasive Purkinje mapping. Purkinje drivers were defined as Purkinje activities faster than the local ventricular rate. Structural substrate was delineated by electrogram criteria and by imaging. Catheter ablation was performed in 41 patients with recurrent VF. Sixty-one episodes of spontaneous (n = 10) or induced (n = 51) VF were mapped. Ventricular fibrillation was organized for the initial 5.0 ± 3.4 s, exhibiting large wavefronts with similar cycle lengths (CLs) across both ventricles (197 ± 23 vs. 196 ± 22 ms, P = 0.9). Most drivers (81%) originated from areas associated with the structural substrate. The Purkinje system was implicated as a trigger or driver in 43% of patients with cardiomyopathy. The transition to disorganized VF was associated with the acceleration of initial reentrant activities (CL shortening from 187 ± 17 to 175 ± 20 ms, P < 0.001), then spatial dissemination of drivers. Purkinje and substrate ablation resulted in the reduction of VF recurrences from a pre-procedural median of seven episodes [interquartile range (IQR) 4-16] to 0 episode (IQR 0-2) (P < 0.001) at 56 ± 30 months. CONCLUSIONS: The onset of human VF is sustained by activities originating from Purkinje and structural substrate, before spreading throughout the ventricles to establish disorganized VF. Targeted ablation results in effective reduction of VF burden. KEY QUESTION: The initial phase of human ventricular fibrillation (VF) is critical as it involves the primary activities leading to sustained VF and arrhythmic sudden death. The origin of such activities is unknown. KEY FINDING: Body-surface mapping shows that most drivers (≈80%) during the initial VF phase originate from electrophysiologically defined structural substrates. Repetitive Purkinje activities can be elicited by programmed stimulation and are implicated as drivers in 37% of cardiomyopathy patients. TAKE-HOME MESSAGE: The onset of human VF is mostly associated with activities from the Purkinje network and structural substrate, before spreading throughout the ventricles to establish sustained VF. Targeted ablation reduces or eliminates VF recurrence.


Asunto(s)
Síndrome de Brugada , Ablación por Catéter , Mapeo del Potencial de Superficie Corporal , Ablación por Catéter/métodos , Electrocardiografía , Ventrículos Cardíacos , Humanos , Fibrilación Ventricular
11.
J Cardiovasc Electrophysiol ; 33(8): 1687-1693, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35637606

RESUMEN

INTRODUCTION: Systematic and quantitative descriptions of vein of Marshall (VOM)-induced tissue ablation are lacking. We sought to characterize the distribution of low voltage observed in the left atrium (LA) after VOM ethanol infusion. METHODS AND RESULTS: The distribution of ethanol-induced low voltage was evaluated by comparing high-density maps performed before and after VOM ethanol infusion in 114 patients referred for atrial fibrillation ablation. The two most frequently impacted segments were the inferior portion of the ridge (82.5%) and the first half of the mitral isthmus (pulmonary vein side) (92.1%). Low-voltage absence in these typical areas resulted from inadvertent ethanol infusion in the left atrial appendage vein (n = 3), initial VOM dissection (n = 3), or a "no branches" VOM morphology (n = 1). Visible anastomosis of the VOM with roof or posterior veins more frequently resulted in low-voltage extension beyond typical areas, toward the entire left antrum (19.0% vs. 1.9%, p = .0045) or the posterior LA (39.7% vs. 3.8%, p < .001) but with a limited positive predictive value ranging from 29.4% to 43.5%. Ethanol-induced low voltage covered a median LA surface of 3.6% (1.9%-5.0%) and did not exceed 8% of the LA surface in 90% of patients. CONCLUSION: VOM ethanol infusion typically locates at the inferior ridge and the adjacent half of the mitral isthmus. Low-voltage extensions can be anticipated but not guaranteed by the presence of visible anastomosis of the VOM with roof or posterior veins.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Etanol/efectos adversos , Atrios Cardíacos/cirugía , Humanos , Venas Pulmonares/cirugía
12.
J Cardiovasc Electrophysiol ; 33(5): 908-916, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35274776

RESUMEN

INTRODUCTION: Due to changes in esophageal position, preoperative assessment of the esophageal location may not mitigate the risk of esophageal injury in catheter ablation for atrial fibrillation (AF). This study aimed to assess esophageal motion and its impact on AF ablation strategies. METHODS AND RESULTS: Ninety-seven AF patients underwent two computed tomography (CT) scans. The area at risk of esophageal injury (AAR) was defined as the left atrial surface ≤3 mm from the esophagus. On CT1, ablation lines were drawn blinded to the esophageal location to create three ablation sets: individual pulmonary vein isolation (PVI), wide antral circumferential ablation (WACA), and WACA with linear ablation (WACA + L). Thereafter, ablation lines for WACA and WACA + L were personalized to avoid the AAR. Rigid registration was performed to align CT1 onto CT2, and the relationship between ablation lines and the AAR on CT2 was analyzed. The esophagus moved by 3.6 [2.7 to 5.5] mm. The AAR on CT2 was 8.6 ± 3.3 cm2 , with 77% overlapping that on CT1. High body mass index was associated with the AAR mismatch (standardized ß 0.382, p < .001). Without personalization, AARs on ablation lines for individual PVI, WACA, and WACA + L were 0 [0-0.4], 0.8 [0.5-1.2], and 1.7 [1.2-2.0] cm2 . Despite the esophageal position change, the personalization of ablation lines for WACA and WACA + L reduced the AAR on lines to 0 [0-0.5] and 0.7 [0.3-1.0] cm2 (p < .001 for both). CONCLUSION: The personalization of ablation lines based on a preoperative CT reduced ablation to the AAR despite changes in esophageal position.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Esófago/lesiones , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 33(6): 1116-1124, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35347799

RESUMEN

INTRODUCTION: The optimal strategy after a failed ablation for persistent atrial fibrillation (perAF) is unknown. This study evaluated the value of an anatomically guided strategy using a systematic set of linear lesions with adjunctive ethanol infusion into the vein of Marshall (Et-VOM) in patients referred for second perAF ablation procedures. METHODS AND RESULTS: Patients with perAF who underwent a second procedure were grouped according to the two strategies. The first strategy was an anatomically guided approach using systematic linear ablation with adjunctive Et-VOM, with bidirectional blocks at the posterior mitral isthmus (MI), roof, and cavotricuspid isthmus (CTI) as the procedural endpoint (Group I). The second one was an electrophysiology-guided strategy, with atrial tachyarrhythmia termination as the procedural endpoint (Group II). Arrhythmia behavior during the procedure guided the ablation strategy. Groups I and II consisted of 96 patients (65 ± 9 years; 71 men) and 102 patients (63 ± 10 years; 83 men), respectively. Baseline characteristics were comparable. In Group I, Et-VOM was successfully performed in 91/96 (95%), and procedural endpoint (bidirectional block across all three anatomical lines) was achieved in 89/96 (93%). In Group II, procedural endpoint (atrial tachyarrhythmia termination) was achieved in 80/102 (78%). One-year follow-up demonstrated Group I (21/96 [22%]) experienced less recurrence compared to Group II (38/102 [37%], Log-rank p = .01). This was driven by lower AT recurrence in Group I (Group I: 10/96 [10%] vs. Group II: 29/102 [28%]; p = .002). CONCLUSION: Anatomically guided strategy with adjunctive Et-VOM is superior to an electrophysiology-guided strategy for second procedures in patients with perAF at 1-year follow-up.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Electrofisiología Cardíaca , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Etanol/efectos adversos , Humanos , Masculino , Venas Pulmonares/cirugía , Recurrencia , Taquicardia , Resultado del Tratamiento
14.
Rev Cardiovasc Med ; 23(1): 14, 2022 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-35092206

RESUMEN

Evidence on sex differences in the pathophysiology and interventional treatment of ventricular arrhythmia in ischemic (ICM) or non-ischemic cardiomyopathies (NICM) is limited. However, women have different etiologies and types of structural heart disease due to sex differences in genetics, proteomics and sex hormones. These differences may influence ventricular electrophysiological parameters and may require different treatment strategies. Considering that women were consistently under-represented in all randomized-controlled trials on VT ablation, the applicability of the study results to female patients is not known. In this article, we review the current knowledge and gaps in evidence about sex differences in the epidemiology, pathophysiology and catheter ablation in patients with ventricular arrhythmias.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Ensayos Clínicos Controlados Aleatorios como Asunto , Caracteres Sexuales , Taquicardia Ventricular/etiología , Resultado del Tratamiento
15.
J Cardiovasc Electrophysiol ; 32(2): 554-557, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33421212

RESUMEN

Brugada syndrome (BrS) is a sudden cardiac death syndrome characterized by a coved-type electrocardiogram (ECG). Different disorders, such as ischemia, can emulate a Brugada-pattern ECG (Brugada phenocopy). We report herein, the first case of surgical epicardial electrophysiological mapping in a successfully resuscitated patient with an anomalous aortic origin of the coronary artery (AAOCA) associated with a coved-type ECG. It was debatable whether the coved-type ECG and the abnormal arrhythmogenic substrate in the epicardial right ventricular outflow tract were derived from BrS or from repetitive ischemia due to AAOCA; however, the epicardial electrophysiological mapping helped in deciding the treatment strategy.


Asunto(s)
Síndrome de Brugada , Vasos Coronarios , Síndrome de Brugada/complicaciones , Síndrome de Brugada/diagnóstico , Muerte Súbita Cardíaca/etiología , Electrocardiografía , Mapeo Epicárdico , Humanos
16.
J Cardiovasc Electrophysiol ; 32(4): 1182-1186, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33634535

RESUMEN

Recent data of electrophysiological mapping in patients with Brugada syndrome (BrS) suggest that the presence of an abnormal arrhythmogenic substrate in the epicardial right ventricular outflow tract is responsible for ST-segment elevation and ventricular fibrillation (VF). Complete elimination of the epicardial abnormal potentials normalizes Brugada-pattern electrocardiogram and suppresses VF recurrence. We herein report the first case of BrS in which an injection of adenosine unmasked dormant conduction in the epicardial RVOT after the disappearance of the epicardial potentials.


Asunto(s)
Síndrome de Brugada , Ablación por Catéter , Adenosina , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/cirugía , Electrocardiografía , Humanos , Fibrilación Ventricular/diagnóstico
17.
J Cardiovasc Electrophysiol ; 32(1): 162-165, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33206428

RESUMEN

Mitral isthmus (MI) ablation is commonly performed as an adjunct therapy to pulmonary isolation during the treatment for persistent atrial fibrillation. Confirmation of complete MI block is essential because an incomplete MI block may result in iatrogenic atrial tachycardia. However, there are several pitfalls in the diagnosis of an MI line block. We herein report a case of transient pause-dependent MI block during MI ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Taquicardia Supraventricular , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Frecuencia Cardíaca , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
18.
J Cardiovasc Electrophysiol ; 32(11): 2987-2994, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34453363

RESUMEN

INTRODUCTION: Ventricular fibrillation (VF) is the main mechanism of sudden cardiac death in patients with hypertrophic cardiomyopathy (HCM). The origin of VF and the success of catheter ablation to eliminate recurrent episodes in this population are poorly understood. METHODS AND RESULTS: From 2010 to 2014, five patients with HCM (age 21 ± 9 years, three female) underwent invasive electrophysiological studies and ablation at our center after resuscitation from recurrent (9 ± 7) episodes of VF. Ventricular premature beats (VPBs), seen to initiate VF in certain cases, were recorded noninvasively before the ablation procedure. Postprocedural computed tomography (CT) was performed to correlate ablation sites with myocardial hypertrophy in three patients. Outcomes were assessed by clinical follow-up and implantable cardioverter-defibrillator interrogations. VPB triggers were localized invasively to the distal left Purkinje conduction system (left posterior fascicle [2], left anterior fascicle [1], and both fascicles [2]). All targeted VF triggers were successfully eliminated by radiofrequency ablation in the left ventricle. Among patients with postablation CT imaging, 93 ± 12% of ablation sites corresponded to hypertrophied segments. Over 50 ± 38 months, four of five patients were free from primary VF without antiarrhythmic drug therapy. One patient who had 13 episodes of VF before ablation had a single recurrence. CONCLUSION: In our study of patients with HCM and recurrent VF, VF was not initiated from the myocardium but rather from Purkinje arborization. These sources colocalized with the hypertrophic substrate, suggesting electromechanical interaction. Focal ablation at these sites was associated with a marked reduction in VF burden.


Asunto(s)
Cardiomiopatía Hipertrófica , Ablación por Catéter , Desfibriladores Implantables , Complejos Prematuros Ventriculares , Adolescente , Adulto , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Niño , Femenino , Humanos , Fibrilación Ventricular/diagnóstico por imagen , Fibrilación Ventricular/etiología , Adulto Joven
19.
J Cardiovasc Electrophysiol ; 32(3): 570-577, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33476463

RESUMEN

BACKGROUND: Ultralow temperature cyroablation (ULTC) is designed to create focal, linear, and circumferential lesions. The aim of this study was to assess the safety, efficacy, and durability of atrial and ventricular ULTC lesions in preclinical large animal models. METHODS AND RESULTS: The ULTC system uses nitrogen near its liquid-vapor critical point to cool 11-cm ablation catheters. The catheter can be shaped to specific anatomies using pre-shaped stylets. ULTC was used in 11 swine and four sheep to create atrial (pulmonary vein isolation and linear ablation) and ventricular lesions. Acute and 90-day success were evaluated by intracardiac mapping and histologic examination. Cryoadherence was observed during all ULTC applications, ensuring catheter stability at target locations. Local electrograms were completely eliminated immediately after the first single-shot ULTC application in 49 of 53 (92.5%) atrial and in 31 of 32 (96.9%) ventricular applications. Lesion depth as measured on histology preparations was 1.96 ± 0.8 mm in atrial and 5.61 ± 2.2 mm in ventricular lesions. In all animals, voltage maps and histology demonstrated transmural and durable lesions without gaps, surrounded by intact collagen fibers without injury to surrounding tissues. Transient coronary spasm could be provoked with endocardial ULTC in the left ventricle in close proximity to a coronary artery. CONCLUSIONS: ULTC created effective and efficient atrial and ventricular lesions in vivo without procedural complications in two large animal models. ULTC lesions were transmural, contiguous, and durable over 3 months.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Animales , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Atrios Cardíacos/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Venas Pulmonares/cirugía , Ovinos , Porcinos , Temperatura
20.
J Cardiovasc Electrophysiol ; 32(8): 2216-2224, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34223662

RESUMEN

INTRODUCTION: Ultrahigh-density mapping for ventricular tachycardia (VT) is increasingly used. However, manual annotation of local abnormal ventricular activities (LAVAs) is challenging in this setting. Therefore, we assessed the accuracy of the automatic annotation of LAVAs with the Lumipoint algorithm of the Rhythmia system (Boston Scientific). METHODS AND RESULTS: One hundred consecutive patients undergoing catheter ablation of scar-related VT were studied. Areas with LAVAs and ablation sites were manually annotated during the procedure and compared with automatically annotated areas using the Lumipoint features for detecting late potentials (LP), fragmented potentials (FP), and double potentials (DP). The accuracy of each automatic annotation feature was assessed by re-evaluating local potentials within automatically annotated areas. Automatically annotated areas matched with manually annotated areas in 64 cases (64%), identified an area with LAVAs missed during manual annotation in 15 cases (15%), and did not highlight areas identified with manual annotation in 18 cases (18%). Automatic FP annotation accurately detected LAVAs regardless of the cardiac rhythm or scar location; automatic LP annotation accurately detected LAVAs in sinus rhythm, but was affected by the scar location during ventricular pacing; automatic DP annotation was not affected by the mapping rhythm, but its accuracy was suboptimal when the scar was located on the right ventricle or epicardium. CONCLUSION: The Lumipoint algorithm was as/more accurate than manual annotation in 79% of patients. FP annotation detected LAVAs most accurately regardless of mapping rhythm and scar location. The accuracy of LP and DP annotations varied depending on mapping rhythm or scar location.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Arritmias Cardíacas , Cicatriz/diagnóstico por imagen , Cicatriz/etiología , Técnicas Electrofisiológicas Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/etiología
SELECCIÓN DE REFERENCIAS