Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
BMC Vet Res ; 16(1): 468, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33261618

RESUMEN

BACKGROUND: Regular physical activity (PA) promotes health and can prevent and treat diseases among both humans and dogs. Unfortunately, most U.S. adults do not meet PA recommendations, and many dogs are also insufficiently active. Veterinary-prescribed PA programs have shown some success in increasing activity among overweight dogs, but the impacts of such programs have not yet been tested for efficacy among otherwise-healthy dogs and owners. In addition, although wearable devices that monitor PA and provide individuals with feedback (e.g., progress toward a daily step goal) can effectively increase human PA, it is unclear what impact similar wearable devices have on human and dog PA when the PA-monitoring devices are worn by dogs. The present study assessed the impact of an 8-week veterinary-prescribed PA program on activity and health among dogs and their owners, and randomized participants (n = 59) to two groups: one in which PA was measured but not visible to participants (n = 30), and one in which PA was measured and real time feedback was visible through a wearable device (n = 29). RESULTS: Participants in both groups showed significant PA increases over the course of the 8-week program. Biomedical testing performed at the veterinary clinic facilitated early diagnosis of systemic illness in one human participant. The frequency of hypertension in human participants decreased significantly from baseline to the end of the program (week 8). Other health indices (e.g., BMI in humans, body weight and BCS in dogs) improved, albeit not to a statistically significant extent, over the course of the program. There were no significant differences on the outcomes of interest between the two experimental conditions. CONCLUSIONS: Veterinary-prescribed PA programs appear promising for increasing PA among insufficiently active but otherwise healthy dogs as well as their owners. Additional testing of veterinary-prescribed PA is warranted, particularly at other types of veterinary clinics (e.g., private practices). Incorporating wearable devices permitting owners to track canine PA did not appear necessary for obtaining these benefits; however, additional studies investigating alternative devices or different time periods may be warranted.


Asunto(s)
Perros/fisiología , Ejercicio Físico , Condicionamiento Físico Animal/fisiología , Caminata , Dispositivos Electrónicos Vestibles/veterinaria , Acelerometría , Animales , Índice de Masa Corporal , Peso Corporal , Femenino , Humanos , Hipertensión/prevención & control , Masculino , Motivación , Mascotas , Teléfono Inteligente , Encuestas y Cuestionarios
2.
Vet Surg ; 48(8): 1429-1436, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31120595

RESUMEN

OBJECTIVE: To determine the influence of a novel surgical guide on the accuracy and technical difficulty of closing wedge osteotomies (CWO). STUDY DESIGN: Ex vivo experimental study. SAMPLE POPULATION: Canine tibia models (n = 40). METHODS: A 20° cranial CWO (CCWO) was created without (standard procedure; STCCWO) or with the aid of a novel wedge osteotomy guide (WOCCWO). Procedures were performed by diplomate (n = 4) and resident (n = 6) surgeons, with each performing 2 STCCWO followed by 2 WOCCWO. To prevent bias, surgeons were unaware of the study purpose until after completing the STCCWO. The wedges were evaluated by comparing the deviation from the 20° target angle, divergence of the 2 osteotomies (osteotomy divergence angle [ODA]), and measurements of the wedge height at the caudomedial cortex (CMC) and caudolateral cortex (CLC). Technique difficulty was explored through a surgeon questionnaire. RESULTS: The WOCCWO resulted in smaller mean ODA (WOCCWO = 0.86°, SD ± 0.38°, P < .001), and smaller mean difference between CMC and CLC (WOCCWO = 0.29 mm, SD ± 0.19, P < .001) than for the STCCWO (4.22°, SD ± 2.16° and 1.39 mm, SD ± 0.65 respectively). Deviation from the target 20° wedge angle was greater after STCCWO (1.46°, SD ± 1.27°) than after WOCCWO (0.53°, SD ± 0.33°, P = .004). No difference was reported regarding the difficulty of the procedures, but resident surgeons stated that they were more likely to use the guide in a clinical setting compared with diplomates. CONCLUSION: The wedge osteotomy guide improved the accuracy of CCWO compared with standard technique. CLINICAL SIGNIFICANCE: The clinical significance of the differences detected in this study is unclear and warrants in vivo investigation.


Asunto(s)
Perros , Osteotomía/veterinaria , Instrumentos Quirúrgicos/veterinaria , Tibia/cirugía , Animales , Femenino , Masculino , Modelos Anatómicos , Modelos Teóricos , Osteotomía/instrumentación , Osteotomía/métodos , Impresión Tridimensional
3.
BMC Vet Res ; 13(1): 48, 2017 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-28187763

RESUMEN

BACKGROUND: Accelerometer-based activity monitoring is a promising new tool in veterinary medicine used to objectively assess activity levels in dogs. To date, it is unknown how device orientation, attachment method, and attachment of a leash to the collar holding an accelerometer affect canine activity data. It was our goal to evaluate whether attachment methods of accelerometers affect activity counts. Eight healthy, client-owned dogs were fitted with two identical neck collars to which two identical activity monitors were attached using six different methods of attachment. These methods of attachment evaluated the use of a protective case, positioning of the activity monitor and the tightness of attachment of the accelerometer. Lastly, the effect of leash attachment to the collar was evaluated. For trials where the effect of leash attachment to the collar was not being studied, the leash was attached to a harness. Activity data obtained from separate monitors within a given experiment were compared using Pearson correlation coefficients and across all experiments using the Kruskal-Wallis Test. RESULTS: There was excellent correlation and low variability between activity monitors on separate collars when the leash was attached to a harness, regardless of their relative positions. There was good correlation when activity monitors were placed on the same collar regardless of orientation. There were poor correlations between activity monitors in three experiments: when the leash was fastened to the collar that held an activity monitor, when one activity monitor was housed in the protective casing, and when one activity monitor was loosely zip-tied to the collar rather than threaded on using the provided metal loop. Follow-up, pair-wise comparisons identified the correlation associated with these three methods of attachment to be statistically different from the level of correlation when monitors were placed on separate collars. CONCLUSIONS: While accelerometer-based activity monitors are useful tools to objectively assess physical activity in dogs, care must be taken when choosing a method to attach the device. The attachment of the activity monitor to the collar should utilize a second, dedicated collar that is not used for leash attachment and the attachment method should remain consistent throughout a study period.


Asunto(s)
Acelerometría/veterinaria , Perros/fisiología , Monitoreo Fisiológico/veterinaria , Actividad Motora/fisiología , Proyectos de Investigación/normas , Animales , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/normas , Reproducibilidad de los Resultados
4.
BMC Vet Res ; 11: 146, 2015 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-26141484

RESUMEN

BACKGROUND: Accelerometers are motion-sensing devices that have been used to assess physical activity in dogs. However, the lack of a user-friendly, inexpensive accelerometer has hindered the widespread use of this objective outcome measure in veterinary research. Recently, a smartphone-based, affordable activity monitor (Whistle) has become available for measurement of at-home physical activity in dogs. The aim of this research was to evaluate this novel accelerometer. Eleven large breed, privately owned dogs wore a collar fitted with both the Whistle device and a previously validated accelerometer-based activity monitor (Actical) for a 24-h time period. Owners were asked to have their dogs resume normal daily activities. Total activity time obtained from the Whistle device in minutes was compared to the total activity count from the Actical device. Activity intensity from the Whistle device was calculated manually from screenshots of the activity bars displayed in the smartphone-application and compared to the activity count recorded by the Actical in the same 3-min time period. RESULTS: A total of 3740 time points were compared. There was a strong correlation between activity intensity of both devices for individual time points (Pearson's correlation coefficient 0.81, p < 0.0001). An even stronger correlation was observed between the total activity data between the two devices (Pearson's correlation coefficient 0.925, p < 0.0001). CONCLUSIONS: Activity data provided by the Whistle activity monitor may be used as an objective outcome measurement in dogs. The total activity time provided by the Whistle application offers an inexpensive method for obtaining at-home, canine, real-time physical activity data. Limitations of the Whistle device include the limited battery life, the need for manual derivation of activity intensity data and data transfer, and the requirement of Wi-Fi and Bluetooth availability for data transmission.


Asunto(s)
Acelerometría/veterinaria , Perros/fisiología , Monitoreo Ambulatorio/veterinaria , Actividad Motora/fisiología , Acelerometría/instrumentación , Animales , Femenino , Masculino , Monitoreo Ambulatorio/instrumentación
5.
Vet Surg ; 43(5): 593-7, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24479885

RESUMEN

OBJECTIVE: To report clinical and histopathologic features of long digital extensor (LDE) tendon mineralization with concurrent cranial cruciate ligament (CCL) rupture in a dog. STUDY DESIGN: Case report. ANIMAL: 1.5-year-old, male castrated, English bulldog mix weighing 31.5 kg. METHODS: Pre- and postoperative orthogonal radiographs, arthroscopic evaluation, arthrotomy with en bloc surgical excision, and histopathologic analysis of the excised LDE tendon. RESULTS: There was radiographic evidence of mineralization in the region of the proximal LDE and stifle instability suggestive of CCL rupture. Arthroscopy, and subsequent arthrotomy, showed complete tearing of the CCL and an intact but grossly thickened LDE. No evidence of avulsion or bony proliferation associated with the LDE was appreciated. Tibial plateau leveling osteotomy (TPLO) and tenectomy of the LDE returned the dog to normal weight-bearing. No evidence of ectopic mineralization in the affected limb or similar clinical signs in the contralateral limb have been observed in 12 months follow-up. CONCLUSIONS: LDE tenectomy followed by stabilization of the stifle by TPLO resulted in a functional outcome. Mineralization without concurrent avulsion of the LDE has not been reported in dogs; however, posterolateral tendon injury in people has been linked to knee instability and cruciate ligament rupture.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Enfermedades de los Perros/cirugía , Perros/lesiones , Osteoartritis/veterinaria , Osteotomía/veterinaria , Tendones , Tibia/cirugía , Animales , Ligamento Cruzado Anterior/cirugía , Perros/cirugía , Masculino , Osteoartritis/cirugía , Rotura/veterinaria , Rodilla de Cuadrúpedos/cirugía
6.
Vet Surg ; 43(4): 495-9, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24617749

RESUMEN

OBJECTIVE: To determine the incidence of fibular penetration during placement of the Synthes® locking TPLO plate with and without the use of a jig. STUDY DESIGN: Cadaveric, experimental study. SAMPLE POPULATION: Cadaveric paired pelvic limbs (n = 8) from skeletally mature dogs. METHODS: Limbs were assigned to 1 of 2 groups (jig-less-TPLO = no jig used; jig-TPLO = jig used). Synthes® locking TPLO plates were applied using proximal screws of excessive length to facilitate identification of fibular penetration. Screw tip locations were identified by dissection and frequency of fibular penetration was compared between groups. RESULTS: None of the jig-TPLO limbs and 6 (75%) of jig-less-TPLO limbs had fibular penetration, a difference that was statistically significant. Fibular penetration was most frequently associated with the most proximal screw. CONCLUSIONS: A significantly higher incidence of fibular penetration occurs when Synthes® locking TPLO is performed without use of a jig.


Asunto(s)
Perros , Osteotomía/veterinaria , Instrumentos Quirúrgicos/veterinaria , Tibia/cirugía , Animales , Cadáver , Osteotomía/instrumentación , Osteotomía/métodos
7.
Vet Med Sci ; 9(4): 1521-1533, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37287388

RESUMEN

BACKGROUND: Canine prostheses have been commercially available for many years but are still in early stages of research, development, and clinical application. OBJECTIVE: To prospectively investigate mid-term clinical outcomes of partial limb amputation with a socket prosthesis (PLASP) in canine patients via a descriptive prospective clinical case series and to describe a clinical protocol for PLASP. METHODS: Client-owned dogs (n = 12) with distal limb pathology for which total limb amputation was recommended were enrolled. Partial limb amputation was performed and a socket prosthesis was moulded and fitted to the limb. Complications, clinical follow-up, and objective gait analysis (OGA) were recorded for at least 6 months. An online survey was completed by owners after study completion. RESULTS: Ten dogs with thoracic limb pathology and two with pelvic limb pathology were included. The most common site of amputation was mid-radius (n = 5). Eleven of 12 dogs demonstrated quadrupedal gait on OGA with mean per cent body weight distribution (%BWD) of 26% on thoracic limb prostheses and a %BWD of 16% for the one pelvic limb prosthesis that OGA data were available for. Complications included prosthesis suspension difficulties (n = 5), pressure sores (4), bursitis (4), postoperative infection (3), prosthesis aversion (2), dermatitis (1), and owner noncompliance (1). Two owners elected to discontinue prosthesis use. CONCLUSIONS: PLASP allowed restoration of quadrupedal gait patterns in most patients. Owners reported overall positive satisfaction, though a high complication rate was observed. PLASP should be considered in select cases as an alternative to total limb amputation for dogs with distal limb pathology.


Asunto(s)
Miembros Artificiales , Enfermedades de los Perros , Perros , Animales , Miembros Artificiales/veterinaria , Amputación Quirúrgica/veterinaria , Miembro Posterior , Complicaciones Posoperatorias/veterinaria , Miembro Anterior , Enfermedades de los Perros/cirugía
8.
Front Vet Sci ; 10: 1249592, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37621864

RESUMEN

Introduction: Extracorporeal shockwave therapy (ESWT) is used as a treatment option for several musculoskeletal pathologies in dogs. When performing ESWT using electrohydraulic devices, sedation is commonly recommended due to the noise and discomfort associated with the treatment. The aim of this study was to compare the tolerance of ESWT delivered by a standard or novel trode in awake canine patients with musculoskeletal disease. Materials and methods: This was a prospective, blinded clinical trial in which dogs with musculoskeletal disease received awake treatment with ESWT with a gradually increasing energy protocol using both standard and novel trodes with an electrohydraulic generator in a randomized fashion. Noise reactivity and tolerance to treatment as measured in number of shocks and energy level achieved were recorded. Results: Forty client-owned dogs with pathology affecting the hips, stifles, elbows, or shoulders were enrolled. Thirty-three dogs completed all three treatment sessions, three dogs completed two sessions, and four dogs completed one session. There was evidence of improved patient tolerability with the novel trode, based on an increased average number of shocks delivered (n ± SD = 848 ± 334 for novel trode; n ± SD = 767 ± 358 for standard trode; p = 0.0384) and higher average treatment energy level achieved (E ± SD = 6.5 ± 2.5 for novel trode; E ± SD = 5.3 ± 2.8 for standard trode; p = < 0.001). Decreased noise reactivity was found to be positively correlated with tolerability of shockwave treatment (energy level: p = 0.0168; number of shocks: p = 0.0097). Discussion: Administration of electrohydraulic ESWT is feasible in select awake patients using a gradually increasing energy protocol, and the tested novel shockwave trode is better tolerated than the standard trode. Further studies are required to determine the efficacy of the novel trode, and if gradually increasing energy protocols are clinically equivalent to current standard protocols that employ a consistent energy level.

9.
Vet Surg ; 40(3): 321-6, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21361988

RESUMEN

OBJECTIVE: To determine the effect of proximal ulnar osteotomy (PUO), distal ulnar osteotomy (DUO), and DUO with release of the interosseous ligament (DOLR) on displacement of the proximal ulna at the radioulnar joint. STUDY DESIGN: Experimental mechanical study. SAMPLE POPULATION: Cadaveric, skeletally mature canine thoracic limb pairs (n=11). METHODS: Thoracic limbs disarticulated at the elbow were randomly assigned to 1 of 2 groups: (A) limbs were tested with no treatment (NOTX), then with PUO; (B) limbs were tested with DUO followed by DOLR. A distraction force was applied to the proximal ulna with the distal limb secured in a frame, and displacement of the proximal ulnar segment at the radioulnar joint was recorded. RESULTS: Mean displacement was 0.36 mm (95% confidence interval [CI]: 0-1.12 mm) in the NOTX group, 4.68 mm (95% CI: 3.82-5.55 mm) for PUO limbs, 0.95 mm (95% CI: 0.52-1.39 mm) for the DUO group, and 4.36 mm (95% CI: 3.71-5.02 mm) for the DOLR group. Mean ulnar displacement of the DOLR group was significantly different compared with the DUO group, but there was no significant difference between the PUO and DOLR groups. CONCLUSIONS: No significant difference was observed in displacement of the proximal ulnar segment after DOLR compared with PUO.


Asunto(s)
Perros/cirugía , Miembro Anterior/cirugía , Ligamentos/cirugía , Osteotomía/veterinaria , Animales , Fenómenos Biomecánicos , Cadáver , Osteotomía/métodos
10.
Am J Vet Res ; 81(10): 790-795, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32969729

RESUMEN

OBJECTIVE: To use the small data approach of the Clinical and Laboratory Standards Institute (CLSI) to evaluate the transferability of reference intervals (RIs) for kinetic variables obtained with instrumented gait analysis (IGA) in dogs from an RI-originator laboratory to another laboratory that used the same data acquisition and analytic techniques for IGA in walking dogs. ANIMALS: 27 adult client-owned dogs without evidence of lameness. PROCEDURES: Dogs were individually walked at their preferred velocity on a pressure-sensing walkway for IGA at the Colorado State University Animal Gait Laboratory (CSU-AGL), and 6 valid trials were analyzed for each dog. The small data approach of the CLSI was then used to evaluate transferability of RIs previously established at the Purdue University Animal Gait Laboratory (PU-AGL). A linear model was used to establish weight-dependent RIs for peak vertical force (PVF). RESULTS: Results indicated that RIs of dynamic weight distribution (DWD), DWD symmetry index, DWD coefficient of variation, PVF symmetry index, and PVF coefficient of variation were transferable from PU-AGL to CSU-AGL, whereas the weight-dependent RIs for PVF were not. Regression slopes for PVF versus body weight were greater for all limbs in dogs tested at the CSU-AGL, compared with historic results for dogs tested at the PU-AGL. CONCLUSIONS AND CLINICAL RELEVANCE: Use of the small data approach method of the CLSI to validate transference of RIs for IGA kinetic variables in walking dogs was simple and efficient to perform and may help facilitate clinical and research collaborations on gait analysis.


Asunto(s)
Análisis de la Marcha , Caminata , Animales , Fenómenos Biomecánicos , Perros , Marcha , Cinética
11.
Front Vet Sci ; 6: 100, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31024938

RESUMEN

Introduction: Socket prostheses for treatment of distal limb pathology are becoming increasingly prevalent in veterinary medicine, however, limited objective data is available. Objectives of the present study were to retrospectively evaluate owner satisfaction, clinical outcomes, and prognostic factors associated with dogs receiving socket prostheses for partial limbs in a larger patient population. Materials and Methods: Client databases of a single prosthesis provider were reviewed to identify owners whose dogs had received a prosthetic device within the last 10 years. An online survey was developed to evaluate owner-reported outcomes. The survey inquired about anatomy of the residuum, concurrent disease, prosthesis use, rehabilitation, activity, complications, and owner satisfaction. Medical records and radiographs were requested from all participants. Radiographs were used to confirm level of amputation and evaluate for osseous complications. Survey responses were analyzed by assigning author-defined numeric scores defining clinical outcome and owner satisfaction. Results: One-hundred thirty-seven owners were contacted. The response rate was 50/137 (37%); 47 responses were analyzed. Forty-six of 47 owners reported positive satisfaction; 1/47 was displeased. Forty-two of 47 dogs were scored to have acceptable to full function; 5/47 had unacceptable clinical function using the author-defined scoring system. A 62% short-term complication rate and a 19% long-term complication rate were reported. Skin sores were the most common short and long-term complication. There was a significant correlation between both clinical outcome scores and owner satisfaction with days per week spent in the prosthesis. Additionally, clinical outcome scores and owner satisfaction significantly varied between dogs with different durations of prosthesis wear with a trend toward better outcomes associated with longer prosthesis wear. Radiographs were obtained for 23/47 dogs to further define level of defect. The most proximal level of defect was mid-radius for the forelimb and mid-tibia for the hind limb. There was no correlation between level of defect and either owner satisfaction or clinical outcome. Discussion/Conclusion: Results of this survey suggest a high degree of owner satisfaction despite substantial complication rates. Based on preliminary data, further evaluation of socket prostheses as a limb-sparing option for treatment of distal limb pathology should be considered. Prospective clinical trials with objective outcome measures are required to draw firm conclusions.

12.
Am J Vet Res ; 80(3): 265-269, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30801216

RESUMEN

OBJECTIVE To compare the effects of 3 walkway cover types on temporospatial and ground reaction force measurements of dogs during gait analysis with a pressure-sensitive walkway (PSW). ANIMALS 35 client- and staff-owned dogs (25 nonlame and 10 lame). PROCEDURES In a crossover study design, all dogs were evaluated at a comfortable walk on a PSW to which 3 cover types (a 0.32-cm-thick corrugated vinyl mat or a 0.32- or 0.64-cm-thick polyvinyl chloride yoga mat) were applied in random order. Temporospatial and ground reaction force measurements were obtained and compared among cover types within the nonlame and lame dog groups. RESULTS Several variables, including maximum peak pressure, maximum force (absolute and normalized as a percentage of body weight), and vertical impulse (absolute and normalized) differed significantly in most comparisons among cover types for both nonlame and lame dogs. There was no significant difference in maximum force values between the 0.32-cm-thick corrugated vinyl and 0.64-cm-thick polyvinyl chloride cover types for both nonlame and lame dogs. CONCLUSIONS AND CLINICAL RELEVANCE To the authors' knowledge, the cover type used during data collection with a PSW is rarely provided in published reports on this topic. The findings in this study suggested that to ensure that PSW data for dogs are collected in a standardized manner, the same cover type should be used during follow-up visits to evaluate clinical outcomes, for the duration of research studies, and at all locations for multi-institutional studies. The cover type should be specified in future PSW studies to allow direct comparisons of findings between studies.


Asunto(s)
Perros/fisiología , Análisis de la Marcha/veterinaria , Marcha , Animales , Fenómenos Biomecánicos , Peso Corporal , Estudios Cruzados , Femenino , Análisis de la Marcha/instrumentación , Masculino , Presión , Caminata
13.
Vet Comp Orthop Traumatol ; 32(3): 173-181, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30873568

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the safety and collect pilot data measuring clinical effects of intravenously administered, adipose-derived, culture-expanded, allogeneic mesenchymal stem cells in dogs with elbow osteoarthritis. MATERIALS AND METHODS: Dogs (n = 13) with naturally occurring elbow osteoarthritis received three intravenous doses of allogeneic canine mesenchymal stem cells via an open-label clinical trial. Primary outcome measures collected over a 6-month study period included objective gait analysis, accelerometry, owner questionnaires and joint fluid analysis. RESULTS: No acute adverse events were observed following repeated intravenous treatment with allogeneic mesenchymal stem cells. A significant improvement in mean client-specific outcome measure (CSOM) activity score and CSOM behaviour score was observed when pre-treatment values were compared with post-treatment values (day >28). In contrast, mean peak vertical force significantly decreased from baseline to post-treatment (>day 28). Weekly activity counts did not show a significant difference between baseline to post-treatment time points. Synovial fluid biomarkers did not change during treatment, and labelled mesenchymal stem cells were rarely detected in synovial fluid samples collected after mesenchymal stem cell administration. CLINICAL SIGNIFICANCE: For dogs with naturally occurring elbow osteoarthritis, intravenous administration of mesenchymal stem cells was clinically well tolerated. While some subjective outcome measures showed significant improvements, objective outcome measures did not confirm similar changes. Further research is needed before intravenous mesenchymal stem cells can be recommended as a treatment for elbow osteoarthritis in dogs.


Asunto(s)
Enfermedades de los Perros/terapia , Trasplante de Células Madre Mesenquimatosas/veterinaria , Osteoartritis/veterinaria , Animales , Células Cultivadas , Perros , Femenino , Miembro Anterior , Masculino , Trasplante de Células Madre Mesenquimatosas/efectos adversos , Células Madre Mesenquimatosas , Osteoartritis/terapia , Resultado del Tratamiento
14.
Am J Vet Res ; 69(2): 298-301, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18241030

RESUMEN

OBJECTIVE: To evaluate changes in pH of peritoneal fluid associated with CO2 insufflation during laparoscopy in dogs. ANIMALS: 13 client-owned dogs and 10 purpose-bred teaching dogs. PROCEDURES: Laparotomy was performed on control dogs; peritoneal fluid pH was measured at time of incision of the abdominal cavity (time 0) and 30 minutes later. Laparoscopic insufflation with CO2 was performed and routine laparoscopic procedures conducted on the teaching dogs. Insufflation pressure was limited to 12 mm Hg. Intraperitoneal fluid pH was measured by use of pH indicator paper at 4 time points. Arterial blood gas analysis was performed at the same time points. RESULTS: Peritoneal fluid pH did not change significantly between 0 and 30 minutes in the control dogs. For dogs with CO2 insufflation, measurements obtained were a mean of 8.5, 24.5, 44.5, and 72.0 minutes after insufflation. The pH of peritoneal fluid decreased significantly between the first (7.825 +/- 0.350) and second (7.672 +/- 0.366) time point. Blood pH decreased significantly between the first (7.343 +/- 0.078), third (7.235 +/- 0.042), and fourth (7.225 +/- 0.038) time points. The PaCO2 increased significantly between the first (39.9 +/- 9.8 mm Hg) and fourth (54.6 +/- 4.4 mm Hg) time points. Base excess decreased significantly between the first and all subsequent time points. CONCLUSIONS AND CLINICAL RELEVANCE: Pneumoperitoneum attributable to CO2 insufflation caused a mild and transient decrease in peritoneal fluid pH in dogs. Changes in peritoneal fluid associated with CO2 insufflation in dogs were similar to those in other animals.


Asunto(s)
Líquido Ascítico/química , Líquido Ascítico/efectos de los fármacos , Dióxido de Carbono/farmacología , Perros , Insuflación/veterinaria , Laparoscopía/veterinaria , Animales , Femenino , Concentración de Iones de Hidrógeno , Histerectomía/veterinaria
15.
Vet Surg ; 37(1): 49-62, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18199057

RESUMEN

OBJECTIVE: To identify surgical techniques performed by veterinary surgeons for the treatment of cranial cruciate ligament disease in large-breed dogs with excessive tibial plateau angle (eTPA), compare their outcomes, identify risk factors for postoperative complications, and compare outcome and complication rate with tibial plateau leveling osteotomy (TPLO) in dogs without eTPA. STUDY DESIGN: Multicenter, case-control study. ANIMALS: eTPA group (TPA>or=35 degrees)=58 dogs (78 stifles); control group (TPA14 degrees. Loss of tibial plateau leveling during convalescence was the most commonly observed major complication; addition of ancillary implants to TPLO significantly reduced its incidence. Postoperative complications were more common in dogs with eTPA than in dogs without eTPA; however, no difference in owner-perceived outcome was identified. CONCLUSIONS: Surgical treatment of dogs with eTPA has a higher complication rate, but comparable outcome to that of dogs without eTPA. CLINICAL RELEVANCE: Postoperative TPA

Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirugía , Perros , Osteotomía/veterinaria , Rodilla de Cuadrúpedos/cirugía , Tibia/cirugía , Animales , Ligamento Cruzado Anterior/patología , Estudios de Casos y Controles , Enfermedades de los Perros/patología , Enfermedades de los Perros/cirugía , Perros/lesiones , Perros/cirugía , Femenino , Masculino , Osteotomía/métodos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/veterinaria , Rodilla de Cuadrúpedos/lesiones , Tibia/lesiones , Resultado del Tratamiento
16.
Top Companion Anim Med ; 33(3): 89-96, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30243365

RESUMEN

Surgical management of postamputation orthopedic disease (PAOD) in canine amputees has rarely been documented, and no reports describing outcome of stifle surgery in canine amputees are available. The objective of this multisite retrospective case series was to describe cases and evaluate satisfaction with and outcome of postamputation orthopedic surgery in canine amputees. Data was obtained through medical records and owner survey responses; data included signalment, amputation cause, diagnosis, surgical treatment, timeframes, and outcome assessment. Outcome was categorized as acceptable or unacceptable, and complications were classified as catastrophic, major, or minor. Eleven thoracic limb amputees and 6 pelvic limb amputees with surgically treated PAOD were identified. Surgically treated PAOD was reported at a median of 9.7 months (range 0.5-110 months) after amputation. All 17 amputees were treated for pelvic limb disease, predominantly for cranial cruciate ligament disease that occurred in 11 of 17 dogs. Major complications following orthopedic surgeries performed in 3 thoracic limb amputees consisted of infection (n = 2) and uncontrolled pain (n = 1). No major complications were reported following orthopedic surgeries performed in pelvic limb amputees. Acceptable mid-to-long-term outcome was achieved in 16 of the 17 canine amputees. Surgical treatment of pelvic limb disease did not appear to be associated with a high number of major complications in this case series. These findings suggest that orthopedic surgery, specifically stifle surgery, in canine amputees might be considered a feasible treatment option. Although there are inherent methodological limitations of retrospective studies and owner surveys, our case series provides new information that might help guide surgical treatment decisions in canine amputees suffering from orthopedic disease. Prospective studies using objective outcome measures evaluating surgical management of PAOD are necessary to confirm the provided information.


Asunto(s)
Amputación Quirúrgica/veterinaria , Enfermedades de los Perros/cirugía , Propiedad , Satisfacción del Paciente , Animales , Enfermedades de los Perros/diagnóstico por imagen , Perros , Femenino , Miembro Anterior/cirugía , Miembro Posterior/cirugía , Humanos , Masculino , Complicaciones Posoperatorias/veterinaria , Resultado del Tratamiento
17.
Am J Vet Res ; 79(3): 317-323, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29466049

RESUMEN

OBJECTIVE To quantitatively measure the amount of pressure induced at the calcaneus and cranial tibial surface of dogs by use of 2 cast configurations. ANIMALS 13 client- or student-owned dogs. PROCEDURES Pressure sensors were placed over the calcaneus and cranial tibial surface. Dogs then were fitted with a fiberglass cast on a pelvic limb extending from the digits to the stifle joint (tall cast). Pressure induced over the calcaneus and proximal edge of the cast at the level of the cranial tibial surface was simultaneously recorded during ambulation. Subsequently, the cast was shortened to end immediately proximal to the calcaneus (short cast), and data acquisition was repeated. Pressure at the level of the calcaneus and cranial tibial surface for both cast configurations was compared by use of paired t tests. RESULTS The short cast created significantly greater peak pressure at the level of the calcaneus (mean ± SD, 0.2 ± 0.07 MPa), compared with peak pressure created by the tall cast (0.1 ± 0.06 MPa). Mean pressure at the proximal cranial edge of the cast was significantly greater for the short cast (0.2 ± 0.06 MPa) than for the tall cast (0.04 ± 0.03 MPa). CONCLUSIONS AND CLINICAL RELEVANCE A cast extended to the level of the proximal portion of the tibia caused less pressure at the level of the calcaneus and the proximal cranial edge of the cast. Reducing the amount of pressure at these locations may minimize the potential for pressure sores and other soft tissue injuries.


Asunto(s)
Moldes Quirúrgicos/veterinaria , Perros , Tibia , Animales , Ligamento Cruzado Anterior , Femenino , Masculino , Presión , Rotación , Rodilla de Cuadrúpedos , Caminata
18.
J Am Vet Med Assoc ; 231(11): 1688-91, 2007 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-18052804

RESUMEN

OBJECTIVE: To identify risk factors for development of excessive tibial plateau angle (TPA) in large-breed dogs with cranial cruciate ligament disease (CCLD). DESIGN: Case-control study. ANIMALS: 58 dogs with excessive TPAs (ie, TPA >or= 35 degrees ; case dogs) and 58 dogs with normal TPAs (ie, TPA or= 35 degrees in both limbs were 13.6 times (95% confidence interval, 2.72 to 68.1) as likely to have been neutered before 6 months of age as were control dogs with TPA

Asunto(s)
Ligamento Cruzado Anterior , Castración/veterinaria , Perros/cirugía , Osteotomía/veterinaria , Rodilla de Cuadrúpedos/cirugía , Tibia/cirugía , Factores de Edad , Animales , Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior , Fenómenos Biomecánicos , Cruzamiento , Estudios de Casos y Controles , Castración/efectos adversos , Enfermedades de los Perros/etiología , Enfermedades de los Perros/patología , Enfermedades de los Perros/cirugía , Perros/lesiones , Femenino , Masculino , Osteotomía/métodos , Factores de Riesgo , Rodilla de Cuadrúpedos/lesiones , Tibia/lesiones , Resultado del Tratamiento
19.
Can Vet J ; 48(2): 169-77, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17334031

RESUMEN

The objective of this study was to assess the type and frequency of cardiac dysrhythmias occurring after routine ovariohysterectomy or orchidectomy in young, healthy dogs by using 2 anesthetic protocols (group I: propofol and isoflurane; group II: thiopental and halothane). Fifty dogs under 2 years of age, judged to be clinically normal by physical examination and standard electrocardiography, were evaluated by using 24-hour ambulatory electrocardiography. The most common dysrhythmias in the postoperative period were 2nd degree atrioventricular block (44%), ventricular premature complexes (44%), and atrial premature complexes (32%). For study purposes, more than 100 ventricular or atrial premature complexes per 24 hours, or any occurrence of R-on-T phenomenon, ventricular or atrial tachycardia were classified as clinically significant arrhythmias. Significant arrhythmias were observed in 9 dogs in the postoperative period, 5 of which were in group I and 4 in group II. All of these dogs were under 1 year of age. The R-on-T phenomenon occurred in 4 dogs in group II and 1 dog in group I. Results from this study show that significant arrhythmias, including R-on-T phenomenon, can occur in the perioperative period in young, healthy dogs undergoing routine surgeries with both protocols used.


Asunto(s)
Arritmias Cardíacas/veterinaria , Enfermedades de los Perros/epidemiología , Perros , Electrocardiografía Ambulatoria/veterinaria , Hipnóticos y Sedantes/farmacología , Complicaciones Posoperatorias/veterinaria , Animales , Animales Recién Nacidos , Arritmias Cardíacas/epidemiología , Perros/fisiología , Perros/cirugía , Electrocardiografía Ambulatoria/métodos , Femenino , Halotano/farmacología , Isoflurano/farmacología , Masculino , Orquiectomía/veterinaria , Ovariectomía/veterinaria , Complicaciones Posoperatorias/epidemiología , Periodo Posoperatorio , Propofol/farmacología , Distribución Aleatoria , Tiopental/farmacología , Factores de Tiempo
20.
Am J Vet Res ; 77(7): 749-55, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27347828

RESUMEN

OBJECTIVE To evaluate accuracy and reliability of 3 novel goniometers for measurement of canine stifle joint angles and compare the results with those obtained with a universal goniometer (UG). SAMPLE 8 pelvic limbs from 4 canine cadavers. PROCEDURES Each limb was secured to a wooden platform at 3 arbitrarily selected fixed stifle joint angles. Goniometry was performed with 2 smartphone-based applications (novel goniometers A and B), a digital goniometer (novel goniometer C), and a UG; 3 evaluators performed measurements in triplicate for each angle with each device. Results were compared with stifle joint angle measurements on radiographs (used as a gold standard). Accuracy was determined by calculation of bias and total error, coefficients of variation were calculated to estimate reliability, and strength of linear association between radiographic and goniometer measurements was assessed by calculation of correlation coefficients. RESULTS Mean coefficient of variation was lowest for the UG (4.88%), followed by novel goniometers B (7.37%), A (7.57%), and C (12.71%). Correlation with radiographic measurements was highest for the UG (r = 0.97), followed by novel goniometers B (0.93), A (0.90), and C (0.78). Constant bias was present for all devices except novel goniometer B. The UG and novel goniometer A had positive constant bias; novel goniometer C had negative constant bias. Total error at 50° and 100° angles was > 5% for all devices. CONCLUSIONS AND CLINICAL RELEVANCE None of the devices accurately represented radiographically measured stifle joint angles. Additional veterinary studies are indicated prior to the use of novel goniometers in dogs.


Asunto(s)
Artrometría Articular/veterinaria , Teléfono Inteligente , Rodilla de Cuadrúpedos/anatomía & histología , Animales , Artrometría Articular/instrumentación , Perros , Radiografía , Reproducibilidad de los Resultados , Rodilla de Cuadrúpedos/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA