Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Radiology ; 248(2): 531-9, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18539890

RESUMEN

PURPOSE: To retrospectively evaluate the influence of postbiopsy hemorrhage on the accuracy of tumor detection at T2-weighted magnetic resonance (MR) imaging, dynamic contrast material-enhanced MR imaging, and diffusion-weighted (DW) MR imaging of prostate cancer, with histologic findings as the reference standard. MATERIALS AND METHODS: The institutional review board approved this study and waived the requirement for informed consent. Forty male patients aged 62-84 years (mean age, 71 years) who had prostate cancer underwent MR imaging of the prostate gland after ultrasonographically (US) guided systematic 12-core-specimen biopsy. The mean time between biopsy and MR imaging was 24 days (range, 6-54 days). T1-weighted, T2-weighted, dynamic contrast-enhanced, and DW imaging examinations were performed at 1.5 T. The prostate was divided, according to the biopsy sites, into eight regions on the MR images. Three reviewers in consensus evaluated each region for hemorrhage and prostate cancer. Statistical evaluations were performed with Mann-Whitney U, Ryan, and Spearman rank correlation tests. RESULTS: Intraglandular hemorrhage was observed in 38 (95%) patients and significantly more often in the peripheral zone (PZ) than in the transition zone (TZ) (P < .001). Degree of hemorrhage did not correlate significantly (P = .536) with time between biopsy and MR imaging. The sensitivity, specificity, and accuracy of combined T2-weighted, dynamic contrast-enhanced, and DW imaging in the diagnosis of prostate cancer were 69%, 85%, and 78%, respectively. Sensitivity and specificity were lower for the TZ than for the PZ. Degree of hemorrhage was significantly lower in regions of positive biopsy findings than in regions of negative biopsy findings (P = .001) and correlated negatively with tumor size (P = .043). CONCLUSION: Interpretation of combined T2-weighted, dynamic contrast-enhanced, and DW MR image findings can yield reasonable diagnostic accuracy in both the PZ (80% [191 of 240 regions]) and the TZ (74% [59 of 80 regions]).


Asunto(s)
Biopsia/efectos adversos , Imagen de Difusión por Resonancia Magnética/métodos , Hemorragia/diagnóstico , Hemorragia/etiología , Neoplasias de la Próstata/diagnóstico , Anciano , Anciano de 80 o más Años , Medios de Contraste , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Neoplasias de la Próstata/patología , Estudios Retrospectivos , Sensibilidad y Especificidad , Estadísticas no Paramétricas , Ultrasonografía Intervencional
2.
J Magn Reson Imaging ; 27(3): 552-6, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18219616

RESUMEN

PURPOSE: To identify age-related changes and differences in the diffusion of water molecules within the prostate, through diffusion-weighted imaging (DWI) of the prostate gland in healthy adult Japanese men. MATERIALS AND METHODS: A total of 114 healthy male volunteers (mean age, 55 years; range, 24-81 years) underwent DWI of the prostate with a single-shot echo-planar imaging (EPI) sequence using b-factors of 0 and 1000 seconds/mm(2). Apparent diffusion coefficient (ADC) values of six locations in the peripheral zone (PZ) and two locations in the central gland (CG) were measured and correlations between region and age were examined. RESULTS: ADC values measured within both PZ and CG regions of the prostate showed a uniform distribution, and no significant differences were found between evaluated regions. However, mean ADC values were 1.64 +/- 0.27 x 10(-3) mm(2)/second for PZ and 1.26 +/- 0.12 x 10(-3) mm(2)/second for CG, representing a significant difference. In addition, significant positive correlations were identified between ADC values for both PZ and CG regions and subject age (r = 0.526, P < 0.0001; r = 0.190, P = 0.0431, respectively). CONCLUSION: ADC values within both PZ and CG regions of the prostate increase with age, and this must be taken into consideration when using DWI in the diagnosis of prostate cancer.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Próstata/anatomía & histología , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Persona de Mediana Edad
3.
Catheter Cardiovasc Interv ; 70(2): 303-8, 2007 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-17630676

RESUMEN

PURPOSE: The purpose of this study was to retrospectively evaluate the feasibility and safety of a transradial approach for non-coronary angiography and interventions. BACKGROUND: Generally, the transradial approach is used for coronary angiography and intervention around the world, and experiences have been widely reported. However, few large studies have examined the transradial approach for vessels other than the coronary or cerebral artery. METHODS: Subjects comprised 329 patients who underwent a total of 400 procedures (285 abdomens, 68 pelvises, and 47 lower limbs) with transradial angiography and interventions between January 1999 and June 2006. Normal Allen test results were confirmed before all procedures. A 130- or 150-cm long 4F catheter modified to our own design was used for angiography and interventions such as transarterial embolization or transarterial chemotherapy. RESULTS: Radial artery access was unachievable in 19 of the 400 procedures (4.8%). The radial artery was injured during 1 procedure (0.2%). In the remaining 380 procedures, sufficient angiography was obtained to grasp the condition of indispensable vessels for diagnosis and interventions scheduled in advance succeeded. Total transradial technical success rate in the series was 95%. Frequency of complications such as radial injury or radial spasm was 1.8%. No cases of local hematoma, hand ischemia, or cerebral infarction were encountered. CONCLUSION: The transradial approach was useful for non-coronary angiography and interventions and offers the advantages of low risk and reduced stress on patients.


Asunto(s)
Angiografía/métodos , Cateterismo Periférico/métodos , Arteria Radial , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Angiografía/efectos adversos , Angiografía/instrumentación , Aortografía/métodos , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/instrumentación , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA