Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Neural Eng ; 20(6)2024 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-38100824

RESUMEN

Objective. The primary challenge faced in the field of neural rehabilitation engineering is the limited advancement in nerve interface technology, which currently fails to match the mechanical properties of small-diameter nerve fascicles. Novel developments are necessary to enable long-term, chronic recording from a multitude of small fascicles, allowing for the recovery of motor intent and sensory signals.Approach. In this study, we analyze the chronic recording capabilities of carbon nanotube yarn electrodes in the peripheral somatic nervous system. The electrodes were surgically implanted in the sciatic nerve's three individual fascicles in rats, enabling the recording of neural activity during gait. Signal-to-noise ratio (SNR) and information theory were employed to analyze the data, demonstrating the superior recording capabilities of the electrodes. Flat interface nerve electrode and thin-film longitudinal intrafascicular electrode electrodes were used as a references to assess the results from SNR and information theory analysis.Main results. The electrodes exhibited the ability to record chronic signals with SNRs reaching as high as 15 dB, providing 12 bits of information for the sciatic nerve, a significant improvement over previous methods. Furthermore, the study revealed that the SNR and information content of the neural signals remained consistent over a period of 12 weeks across three different fascicles, indicating the stability of the interface. The signals recorded from these electrodes were also analyzed for selectivity using information theory metrics, which showed an information sharing of approximately 1.4 bits across the fascicles.Significance. The ability to safely and reliably record from multiple fascicles of different nerves simultaneously over extended periods of time holds substantial implications for the field of neural and rehabilitation engineering. This advancement addresses the limitation of current nerve interface technologies and opens up new possibilities for enhancing neural rehabilitation and control.


Asunto(s)
Nanotubos de Carbono , Tejido Nervioso , Ratas , Animales , Electrodos Implantados , Nervio Ciático/fisiología , Electrodos , Relación Señal-Ruido , Nervios Periféricos/fisiología
2.
J Neural Eng ; 21(3)2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38834054

RESUMEN

Objective. Therapeutic brain stimulation is conventionally delivered using constant-frequency stimulation pulses. Several recent clinical studies have explored how unconventional and irregular temporal stimulation patterns could enable better therapy. However, it is challenging to understand which irregular patterns are most effective for different therapeutic applications given the massively high-dimensional parameter space.Approach. Here we applied many irregular stimulation patterns in a single neural circuit to demonstrate how they can enable new dimensions of neural control compared to conventional stimulation, to guide future exploration of novel stimulation patterns in translational settings. We optogenetically excited the septohippocampal circuit with constant-frequency, nested pulse, sinusoidal, and randomized stimulation waveforms, systematically varying their amplitude and frequency parameters.Main results.We first found equal entrainment of hippocampal oscillations: all waveforms provided similar gamma-power increase, whereas no parameters increased theta-band power above baseline (despite the mechanistic role of the medial septum in driving hippocampal theta oscillations). We then compared each of the effects of each waveform on high-dimensional multi-band activity states using dimensionality reduction methods. Strikingly, we found that conventional stimulation drove predominantly 'artificial' (different from behavioral activity) effects, whereas all irregular waveforms induced activity patterns that more closely resembled behavioral activity.Significance. Our findings suggest that irregular stimulation patterns are not useful when the desired mechanism is to suppress or enhance a single frequency band. However, novel stimulation patterns may provide the greatest benefit for neural control applications where entraining a particular mixture of bands (e.g. if they are associated with different symptoms) or behaviorally-relevant activity is desired.


Asunto(s)
Hipocampo , Optogenética , Optogenética/métodos , Hipocampo/fisiología , Animales , Ritmo Teta/fisiología , Masculino
3.
J Neurosci Methods ; 315: 48-54, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30641091

RESUMEN

BACKGROUND: Kilohertz frequency alternating currents (KHFAC) produce rapid nerve conduction block of mammalian peripheral nerve and have potential clinical applications in reducing peripheral nerve hyperactivity. The experimental investigation of KHFAC nerve block requires a robust output measure and this has proven to be the block threshold (BT), the lowest current or voltage at which the axons of interest are completely blocked. All significant literature in KHFAC nerve block, both simulations and experimental, were reviewed to determine the block threshold method that was used. The two common methods used are the High-Low method experimentally and the Binary search method for simulations. NEW METHOD: Four methods to measure the block threshold (High-Low, High-Low-High, Binary and Random) at three frequencies (10, 20 and 30 kHz) were compared through randomized repeated experiments in the in-vivo rodent sciatic nerve-gastrocnemius model. RESULTS: The literature review showed that more than 50% of publications did not measure the block threshold. The experimental results showed no statistical difference in the BT value between the four methods. COMPARISON WITH EXISTING METHOD(S): However, there were differences in the number of significant onset responses, depending on the method. The run time for the BT determination was the shortest for the High-Low method. CONCLUSIONS: It is recommended that all research in electrical nerve block, including KHFAC, should include measurement of the BT. The High-Low method is recommended for most experimental situations but the Binary method could also be a viable option, especially where onset responses are minimal.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Bloqueo Nervioso/métodos , Animales , Músculo Esquelético/fisiología , Conducción Nerviosa , Distribución Aleatoria , Ratas Sprague-Dawley , Nervio Ciático/fisiología
4.
Sci Rep ; 8(1): 14149, 2018 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-30237487

RESUMEN

Interfaces with the peripheral nerve provide the ability to extract motor activation and restore sensation to amputee patients. The ability to chronically extract motor activations from the peripheral nervous system remains an unsolved problem. In this study, chronic recordings with the Flat Interface Nerve Electrode (FINE) are employed to recover the activation levels of innervated muscles. The FINEs were implanted on the sciatic nerves of canines, and neural recordings were obtained as the animal walked on a treadmill. During these trials, electromyograms (EMG) from the surrounding hamstring muscles were simultaneously recorded and the neural recordings are shown to be free of interference or crosstalk from these muscles. Using a novel Bayesian algorithm, the signals from individual fascicles were recovered and then compared to the corresponding target EMG of the lower limb. High correlation coefficients (0.84 ± 0.07 and 0.61 ± 0.12) between the extracted tibial fascicle/medial gastrocnemius and peroneal fascicle/tibialis anterior muscle were obtained. Analysis calculating the information transfer rate (ITR) from the muscle to the motor predictions yielded approximately 5 and 1 bit per second (bps) for the two sources. This method can predict motor signals from neural recordings and could be used to drive a prosthesis by interfacing with residual nerves.


Asunto(s)
Músculos Isquiosurales/fisiología , Recuperación de la Función/fisiología , Nervio Ciático/fisiología , Interfaz Usuario-Computador , Animales , Perros , Electrodos Implantados , Electromiografía , Marcha/fisiología , Caminata/fisiología
5.
J Neural Eng ; 14(5): 056009, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28675376

RESUMEN

OBJECTIVE: Multi-channel cuff electrodes have recently been investigated for extracting fascicular-level motor commands from mixed neural recordings. Such signals could provide volitional, intuitive control over a robotic prosthesis for amputee patients. Recent work has demonstrated success in extracting these signals in acute and chronic preparations using spatial filtering techniques. These extracted signals, however, had low signal-to-noise ratios and thus limited their utility to binary classification. In this work a new algorithm is proposed which combines previous source localization approaches to create a model based method which operates in real time. APPROACH: To validate this algorithm, a saline benchtop setup was created to allow the precise placement of artificial sources within a cuff and interference sources outside the cuff. The artificial source was taken from five seconds of chronic neural activity to replicate realistic recordings. The proposed algorithm, hybrid Bayesian signal extraction (HBSE), is then compared to previous algorithms, beamforming and a Bayesian spatial filtering method, on this test data. An example chronic neural recording is also analyzed with all three algorithms. MAIN RESULTS: The proposed algorithm improved the signal to noise and signal to interference ratio of extracted test signals two to three fold, as well as increased the correlation coefficient between the original and recovered signals by 10-20%. These improvements translated to the chronic recording example and increased the calculated bit rate between the recovered signals and the recorded motor activity. SIGNIFICANCE: HBSE significantly outperforms previous algorithms in extracting realistic neural signals, even in the presence of external noise sources. These results demonstrate the feasibility of extracting dynamic motor signals from a multi-fascicled intact nerve trunk, which in turn could extract motor command signals from an amputee for the end goal of controlling a prosthetic limb.


Asunto(s)
Algoritmos , Modelos Neurológicos , Nervios Periféricos/fisiología , Animales , Teorema de Bayes , Perros , Electromiografía/métodos , Humanos , Músculo Esquelético/inervación , Músculo Esquelético/fisiología , Nervio Ciático/fisiología
6.
Sci Rep ; 7(1): 11723, 2017 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-28916761

RESUMEN

The ability to reliably and safely communicate chronically with small diameter (100-300 µm) autonomic nerves could have a significant impact in fundamental biomedical research and clinical applications. However, this ability has remained elusive with existing neural interface technologies. Here we show a new chronic nerve interface using highly flexible materials with axon-like dimensions. The interface was implemented with carbon nanotube (CNT) yarn electrodes to chronically record neural activity from two separate autonomic nerves: the glossopharyngeal and vagus nerves. The recorded neural signals maintain a high signal-to-noise ratio (>10 dB) in chronic implant models. We further demonstrate the ability to process the neural activity to detect hypoxic and gastric extension events from the glossopharyngeal and vagus nerves, respectively. These results establish a novel, chronic platform neural interfacing technique with the autonomic nervous system and demonstrate the possibility of regulating internal organ function, leading to new bioelectronic therapies and patient health monitoring.


Asunto(s)
Sistema Nervioso Autónomo , Biotecnología/métodos , Estimulación Eléctrica , Microelectrodos , Nanotubos de Carbono , Animales , Electrodos Implantados , Nervio Glosofaríngeo , Humanos , Ratas , Programas Informáticos , Nervio Vago
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA