Europace ; 21(1): 130-136, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-29955890

RESUMEN

AIMS: Remote monitoring (RM) is considered as a standard of care for pacemaker recipients. Remote monitoring systems provide calendar-based intracardiac electrogram recordings (IEGM) only with the current pacemaker settings (passive IEGM). PREMS (Pacemaker Remote Electrogram Monitoring Study), an observational, multicentre trial, prospectively evaluated the clinical value of an active IEGM (aIEGM), including three 10-s sections (passive IEGM, encouraged sensing, and encouraged pacing), compared to other RM data and to its passive IEGM section. Secondary objectives included the added value of the aIEGM to fully assess the sensing and pacing functions of each lead. METHODS AND RESULTS: Patients were enrolled within 3 months after pacemaker implantation and followed until the first transmitted aIEGM, which was analysed together with all other RM data. In total, 567 patients were enrolled (79 ± 9 years, 62% men, 19% single-chamber, and 81% dual-chamber pacemakers). Of 547 aIEGMs transmitted in 547 patients, 161 [29.4%; 95% confidence interval (95% CI) 25.6-33.3%] indicated at least one anomaly non-detectable with certainty-or at all-on other RM data, including atrial arrhythmia, extrasystoles, undersensing, oversensing, and loss of capture. In 21.7% of cases the detected events deserved a corrective action. The sensing and pacing function of each lead could be fully assessed in 77.3% of aIEGM (95% CI 72.6-82.0%) vs. 15.5% (95% CI 11.4-19.6%) when considering only the passive IEGM section (P < 0.001). CONCLUSION: An active IEGM improves the clinical value of remote pacemaker follow-up. Furthermore, compared to a passive IEGM, the aIEGM increases the capability to fully assess remotely the sensing and pacing functions.


Asunto(s)
Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Técnicas Electrofisiológicas Cardíacas , Marcapaso Artificial , Tecnología de Sensores Remotos , Telemedicina , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Femenino , Francia , Frecuencia Cardíaca , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
2.
Arch Cardiovasc Dis ; 112(3): 153-161, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30594571

RESUMEN

BACKGROUND: Long PR intervals may increase cardiovascular complications, including atrial fibrillation. In pacemakers, the SafeR™ mode monitors PR intervals, switching from AAI to DDD when criteria for atrioventricular block are met. AIMS: The PRECISE study evaluated the incidence and predictors of long PR intervals and their association with incident atrial fibrillation after 1 year in patients implanted for sinus node dysfunction and free from significant conduction disorders at baseline. METHODS: This French, prospective, multicentre, observational trial enrolled patients implanted with a REPLY™ dual-chamber pacemaker. Pacemaker memory recorded long PR intervals (defined as first-degree atrioventricular block mode switches occurring after six consecutive PR/AR intervals≥350/450ms) and atrial fibrillation incidence (fallback mode switch>1minute/day). Predictors were identified from baseline variables (age, sex, AR and PR intervals, atrial rhythm disorder and medication) using logistic regression. RESULTS: Of 291 patients with sinus node dysfunction enrolled, 214 were free from significant conduction disorders at baseline (mean age 79±8 years; 44% men; PR/AR intervals<350/450ms). After 1 year, long PR intervals had occurred in 116 patients (54%) and atrial fibrillation in 63 patients (30%). Amiodarone was the only independent predictor of long PR interval occurrence (odds ratio 2.50, 95% confidence interval 1.20-5.21; P=0.014). There was a strong trend towards an association between long PR interval and atrial fibrillation incidence (odds ratio 1.86, 95% confidence interval 0.97-3.61; P=0.051). CONCLUSIONS: Half of the patients with pure sinus node dysfunction developed long PR intervals in the year following pacemaker implantation. Amiodarone was the only independent predictor of long PR intervals. There was a strong trend towards an association between long PR intervals and incident atrial fibrillation.


Asunto(s)
Estimulación Cardíaca Artificial , Frecuencia Cardíaca , Marcapaso Artificial , Síndrome del Seno Enfermo/terapia , Nodo Sinoatrial/fisiopatología , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Amiodarona/uso terapéutico , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/fisiopatología , Diseño de Equipo , Femenino , Francia/epidemiología , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Incidencia , Masculino , Estudios Prospectivos , Factores de Riesgo , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/epidemiología , Síndrome del Seno Enfermo/fisiopatología , Factores de Tiempo , Resultado del Tratamiento