Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Circ J ; 88(7): 1118-1124, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38616125

RESUMEN

BACKGROUND: Despite an increased incidence of chronic heart failure (HF) and sudden cardiac death (SCD), the use of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy (CRT) is much lower in Japan than in Western countries. The HF Indication and SCD Prevention Trial Japan (HINODE) prospectively assessed the mortality rate, appropriately treated ventricular arrhythmias (VA), and HF in Japanese patients with a higher risk of HF.Methods and Results: HINODE consisted of ICD, CRT-defibrillator (CRT-D), pacing, and non-device treatment cohorts. This subanalysis evaluated the impact of the implantation of high-voltage devices (HVD; ICD and CRT-D) in 171 Japanese patients. We compared all-cause mortality, VA, and HF events between elderly (age >70 years at study enrollment) and non-elderly HVD recipients. The estimated survival rate through 24 months in the HVD cohort was 85.8% (97.5% lower control limit 77.6%). The risk of all-cause mortality was increased for the elderly vs. non-elderly (hazard ratio [HR] 2.82; 95% confidence interval [CI] 1.01-7.91; P=0.039), but did not differ after excluding ICD patients with CRT-D indication (HR 2.32; 95% CI 0.79-6.78; P=0.11). There were no differences in VA and HF event-free rates between elderly and non-elderly HVD recipients (P=0.73 and P=0.55, respectively). CONCLUSIONS: Although elderly patients may have a higher risk of mortality in general, the benefit of HVD therapy in this group is comparable to that in non-elderly patients.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Anciano , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Masculino , Femenino , Japón/epidemiología , Anciano de 80 o más Años , Persona de Mediana Edad , Prevención Primaria , Estudios Prospectivos , Muerte Súbita Cardíaca/prevención & control , Factores de Edad , Factores de Riesgo , Pueblos del Este de Asia
2.
Int Heart J ; 65(2): 354-358, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38556343

RESUMEN

Although long-QT syndrome (LQTS) with a normal range QT interval at rest leads to fatal ventricular arrhythmias, it is difficult to diagnose. In this article, we present a rare case of a patient who suffered a cardiac arrest and was recently diagnosed with LQTS and coronary vasospasm. A 62-year-old man with no syncopal episodes had a cardiopulmonary arrest while running. During coronary angiography, vasospasm was induced and we prescribed coronary vasodilators, including calcium channel blockers. An exercise stress test was performed to evaluate the effect of medications and accidentally unveiled exercise-induced QT prolongation. He was diagnosed with LQTS based on diagnostic criteria. Pharmacotherapy and an implantable cardioverter defibrillator were used for his medical management. It is extremely rare for LQTS and coronary vasospasm to coexist. In cases of exercise-induced arrhythmic events, the exercise stress test might be helpful to diagnose underlying disease.


Asunto(s)
Vasoespasmo Coronario , Paro Cardíaco , Síndrome de QT Prolongado , Masculino , Humanos , Persona de Mediana Edad , Fibrilación Ventricular/complicaciones , Fibrilación Ventricular/diagnóstico , Vasoespasmo Coronario/complicaciones , Vasoespasmo Coronario/diagnóstico , Electrocardiografía , Síndrome de QT Prolongado/complicaciones , Síndrome de QT Prolongado/diagnóstico , Arritmias Cardíacas/complicaciones , Paro Cardíaco/complicaciones
3.
Int Heart J ; 64(6): 1025-1031, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38030289

RESUMEN

The number of TV-PM implantations in elderly people is increasing. Although frailty syndrome is common in elderly patients, the relationship between the pre-procedural frailty status and clinical outcomes has not been fully elucidated in elderly TV-PM recipients.This study included 103 consecutive patients over 80 years old who were newly implanted with a TV-PM (age 85.7 ± 4.2, 41.7% male). We assessed the relationship between the clinical outcome and predictive factors, especially for the pre-procedural frailty status after the TV-PM implantation. The pre-procedural frailty status was retrospectively assessed from the medical records and classified on the basis of impairments in 3 domains (walking, cognition, and activities of daily living). The primary endpoint was defined as a heart failure admission.During the follow-up period (4.1 ± 2.3 years), 20 patients (19.4%) met the primary endpoint. Frailty syndrome was identified in 40 patients (38.8%). In univariate analysis, the LVEF (HR 0.97, 95% CI 0.96-1.00 P = 0.0492), an RV pacing burden over 40% (HR 1.58, 95% CI 1.00-2.54 P = 0.0473), and presence of a frailty status (HR 1.82, 95% CI 1.13-2.87 P = 0.0134) were found to be statistically significant predictors for the study endpoint. In multivariate analysis, having frailty syndrome was the only predictive factor for a heart failure admission (HR 1.83, 95% CI 1.12-2.93 P = 0.0157).The presence of frailty syndrome and incidence of clinical events were high and a pre-procedural frailty status assessment was key in determining the clinical outcomes in TV-PM recipients over 80 years old.


Asunto(s)
Fragilidad , Insuficiencia Cardíaca , Marcapaso Artificial , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Femenino , Fragilidad/epidemiología , Anciano Frágil , Estudios Retrospectivos , Actividades Cotidianas , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia
4.
Circ J ; 86(2): 299-308, 2022 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-34629373

RESUMEN

BACKGROUND: Radiofrequency catheter ablation (RFCA) is an effective therapy for atrial fibrillation (AF). However, it the problem of AF recurrence remains. This study investigates whether a deep convolutional neural network (CNN) can accurately predict AF recurrence in patients with AF who underwent RFCA, and compares CNN with conventional statistical analysis.Methods and Results:Three-hundred and ten patients with AF after RFCA treatment, including 94 patients with AF recurrence, were enrolled. Nine variables are identified as candidate predictors by univariate Cox proportional hazards regression (CPH). A CNNSurv model for AF recurrence prediction was proposed. The model's discrimination ability is validated by a 10-fold cross validation method and measured by C-index. After back elimination, 4 predictors are used for model development, they are N-terminal pro-BNP (NT-proBNP), paroxysmal AF (PAF), left atrial appendage volume (LAAV) and left atrial volume (LAV). The average testing C-index is 0.76 (0.72-0.79). The corresponding calibration plot appears to fit well to a diagonal, and the P value of the Hosmer-Lemeshow test also indicates the proposed model has good calibration ability. The proposed model has superior performance compared with the DeepSurv and multivariate CPH. The result of risk stratification indicates that patients with non-PAF, higher NT-proBNP, larger LAAV and LAV would have higher risks of AF recurrence. CONCLUSIONS: The proposed CNNSurv model has better performance than conventional statistical analysis, which may provide valuable guidance for clinical practice.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Aprendizaje Profundo , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Recurrencia , Resultado del Tratamiento
5.
Pacing Clin Electrophysiol ; 44(1): 192-193, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32779758

RESUMEN

A 78-year-old male with a history of a cardiac embolic stroke due to persistent AF and cerebral bleeding (CHADS2 score 4, HAS-BLED score 4) was referred to our hospital to implant a left atrial appendage (LAA) closure (LAAC) device. A trans esophageal echocardiography was performed and a high echoic lesion that was difficult to differentiate the spontaneous echo contrast or thrombus was found in the LAA cavity. After isoproterenol infusion, a high echoic lesion disappeared and we confirmed that it was not an LAA thrombus. Successful LAAC device implantation was performed without any thromboembolic events.


Asunto(s)
Agonistas Adrenérgicos beta/administración & dosificación , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Isoproterenol/administración & dosificación , Dispositivo Oclusor Septal , Anciano , Ecocardiografía Transesofágica , Humanos , Infusiones Intravenosas , Imagen por Resonancia Magnética , Masculino
6.
Pacing Clin Electrophysiol ; 44(11): 1810-1816, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34554589

RESUMEN

BACKGROUND: Transvenous implantable cardioverter defibrillator (TV-ICD) systems are commonly implanted in the left anterior chest because of an easier implantation and better defibrillation threshold. This study aimed to evaluate the safety and feasibility of left axillary implantations of TV-ICD systems. METHODS: We performed left axillary TV-ICD implantations and compared that to the major complication rate and operation time of the conventional TV-ICD implantation site (left anterior chest). The electrical parameter trends were also assessed in the left axilla group. RESULTS: Seventy-six consecutive patients were evaluated for the analysis. Thirty-one patients had their system implanted in the left axilla and the reasons for the implantations included 29 patients for cosmetic reasons and two for post-infection conditions. The operation time and major complication rate were similar between the two groups (left anterior chest vs. left axilla: 134±62.4 min vs. 114±33.5 min, p = .11, 1/45 patient, 2.2% [pocket hematoma] vs. 1/31 patient, 3.2% [lead dislodgement], p = .77). During the follow up period (4.9±2.3years), no lead interruptions were observed in either group. The electrical lead parameters at the time of the implantation and follow up were similar in the study group (R wave sensing 20.8±33.4 vs. 11.2±7.42 mv, p = .34; lead impedance 464±64.7 vs. 418±135ohm, p = .22; pacing threshold [at 0.4 ms] 1.0±0.76 vs. 1.21±0.93V, p = .49). CONCLUSION: TV-ICD implantations in the left axilla were performed safely without increasing the operation time as compared to the conventional ICD implantation site. ICD implantations in the left axilla are an alternative in those not suitable for implanting TV-ICDs in the conventional implantation site.


Asunto(s)
Axila/cirugía , Desfibriladores Implantables , Seguridad del Paciente , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos
7.
Heart Vessels ; 36(9): 1438-1444, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33740089

RESUMEN

There is increased interest in creating high-power short duration (HPSD) ablation lesions in the field of atrial fibrillation (AF) radiofrequency ablation (RFA). We evaluated the lesion characteristics and collateral damage using two separate RFA protocols setting (HPSD: 50 W and 7 s vs control: 25 W and 30 s) in vitro model. Sixteen freshly killed porcine hearts were obtained, and the atrium and ventricle slabs were harvested for ablation. The each slabs were placed in a tissue bath with circulating 0.9% NaCl at maintained temperature 37 °C. RFA was performed with 4 mm tip irrigated force sensing catheter. All lesions were ablated under recording the electrical parameters using with Ensite Navx system (St. Jude Medical, St. Paul, Minnesota). After RFA, lesion characteristics were assessed for each lesion. Thirty-five lesions were made for each ablation protocol (total 70 lesions for analysis). Ablation parameters were similar between two groups (HPSD vs control; impedance drop (Ω): 34.2 ± 13.1 vs 36.1 ± 8.65 P = 0.49, contact force (g): 13.9 ± 4.37 vs 14.6 ± 5.09, P = 0.51, lesion size index: 4.8 ± 0.52 vs 4.73 ± 0.59, P = 0.62). Although the lesion volume was similar, the HPSD ablation creates wider but more shallower lesions compared to control group (HPSD vs control; lesion volume: 29.6 ± 18.1 mm3 vs 35.5 ± 17.1 mm3 P = 0.16, lesion diameter: 4.98 ± 0.91 mm vs 4.45 ± 0.74 mm P = 0.0095, lesion depth: 2.2 ± 0.76 mm vs 2.8 ± 1.56 mm P = 0.046). Of these, 38 lesions were assessed for adjacent tissue damage and adjacent tissue damages were more frequent seen in control group (HPSD vs control; 1/19 (5.26%) vs 6/19 (31.5%), P = 0.036). Effective lesions were made with HPSD, thereby reducing RFA procedure time. Although the lesion volume was similar between two groups, collateral damage was less seen in HPSD group attributed by lesion characteristics.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Ablación por Radiofrecuencia , Animales , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ventrículos Cardíacos , Porcinos , Factores de Tiempo
8.
J Electrocardiol ; 66: 114-121, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33906059

RESUMEN

BACKGROUND: Atrial fibrillation (AF) induces functional mitral regurgitation (FMR) and tricuspid regurgitation (FTR) during atrial remodeling. FMR and FTR are associated with AF prognosis, but the effects for AF recurrence after ablation have not been determined conclusively. METHODS: Two hundred thirty nine patients who underwent AF ablation were enrolled. Forty five patients were excluded. In total, 194 patients were analyzed. FMR and FTR were assessed by echocardiography. The left atrial volume index (LAVI) was evaluated by contrast-enhanced computed tomography. RESULTS: Significant FMR and moderate FTR were observed in 15 (7.7%) and in 25 (12.9%) patients, respectively. The severity of tricuspid regurgitation (TR) significant correlated with age, NT-proBNP, and LAVI. During a 13.4 month follow-up period of, 39 patients (20.1%) demonstrated AF recurrence. In the Cox proportional-hazards model, E/e', FTR, and LAVI, were termed as predictor factors of AF recurrence (E/e'. hazard ratio [HR] = 1.117; P = 0.019, significant FTR. HR = 4.679; P = 0.041, LAVI. HR = 1.057; P = 0.003). Kaplan-Meier analysis showed that AF recurrence was more frequent in FTR compared with the nonsignificant FTR cases (log-rank, P = 0.001). Although survival analysis showed no difference with or without FMR, the presence of FMR and FTR was strongly associated with high-AF recurrence (log-rank, P = 0.004). CONCLUSIONS: AF recurrence was associated with E/e', LAVI, and extensive FTR. Specifically, the combination of FTR and FMR markedly worsens the AF prognosis.


Asunto(s)
Fibrilación Atrial , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Fibrilación Atrial/cirugía , Electrocardiografía , Atrios Cardíacos , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
9.
Int Heart J ; 60(6): 1444-1447, 2019 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-31666453

RESUMEN

A healthy 73-year-old woman unpredictably developed Takotsubo cardiomyopathy syndrome (TTS) during Holter-electrocardiogram (ECG) recording. Thus, the complete chronological ECG data on the actual onset day of TTS were obtained. Many heart rate variability (HRV) parameters, including the low-frequency components (LF) and the high-frequency components (HF), on the actual onset day and in the healing phase were calculated. The interesting facts on the actual onset day were that the suppression of both LF and HF appeared earlier than the changes of the ECG waveform; and the LF/HF ratio remained within the normal range, although both LF and HF were markedly suppressed. The abnormality on the actual onset day was clear compared with the healing phase. It is noteworthy to obtain the chronological ECG data on the actual onset day of TTS in a healthy patient. The present data are unique in terms of being analyzed on the actual onset day. Although the HRV parameters, including LF and HF, were obviously abnormal, there is some skepticism about using HRV parameters as indices of cardiac autonomic activity. In the present case, it was concluded that the abnormality of cardiac autonomic activity contributed to the onset of TTS. These data are unlikely to ever be replicated, and we hope that this report helps elucidate the TTS mechanism.


Asunto(s)
Frecuencia Cardíaca/fisiología , Cardiomiopatía de Takotsubo/diagnóstico , Cardiomiopatía de Takotsubo/fisiopatología , Anciano , Electrocardiografía Ambulatoria , Femenino , Humanos
10.
Int Heart J ; 59(2): 439-442, 2018 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-29526888

RESUMEN

A 70-years-old male with a history of hypertension and drug resistant paroxysmal atrial fibrillation (AF) presented to our hospital for catheter ablation to his symptomatic AF. He had no prior surgical or percutaneous procedure to close or exclude the left atrial appendage (LAA). A transesophageal echocardiography (TEE) was performed to rule out intra-cardiac thrombus prior to the ablation procedure. Although the TEE imaging at multiple acquisition angles was obtained, the LAA could not be visualized and an absence of the LAA was suspected. An absence of the LAA was confirmed using cardiac computed tomography (CT), which included 3D reconstruction. Additionally, the LAA was not visualized with left atrium (LA) angiography. During the ablation procedure, 3D voltage mapping in LA was created and no low voltage area or abnormal potential was recorded around the usual root location of the LAA. Successful electrical pulmonary vein isolation was achieved with no major complications. After six months of follow-up, the patient remained in sinus rhythm without any antiarrhythmic drugs and showed no related clinical symptoms. He stopped his anticoagulation therapy due to lack of evidence of AF recurrence and an absence of LAA. Multimodality imaging allowed us to identify the congenital absence of LAA.


Asunto(s)
Apéndice Atrial/anomalías , Apéndice Atrial/diagnóstico por imagen , Imagen Multimodal , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia , Ecocardiografía Transesofágica , Humanos , Imagenología Tridimensional , Masculino , Tomografía Computarizada por Rayos X
11.
Int Heart J ; 58(6): 874-879, 2017 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-29118302

RESUMEN

Defibrillation threshold (DFT) testing during implantable cardioverter defibrillator (ICD) implantations is considered necessary for appropriate shock therapy and to measure the safety margin. However, the relationship between the DFT with modern era devices and the clinical outcome, including the total mortality is limited, which may lead to DFT testing itself being questioned. This study aimed to evaluate the relationship between the DFT and clinical outcome in ICD recipients.We enrolled 81 consecutive patients (66 males, aged 64.6 ± 13.8 years) who received an ICD implantation and underwent DFT testing. The DFT was measured with a step-by-step method in the patients upon implant. Further, we evaluated the relationship between the DFT and the clinical outcome, which included major cardiac adverse events and any cause of death.The mean DFT was 11.6 ± 9.24J in total. In 40 patients (49.4%), VF was terminated by a low output (5J), whereas 11 patients (13.6%) had a high DFT. The rates of atrial fibrillation were significantly higher in the high DFT group (63.6% versus 24.2%, P = 0.007). During the observational period (median 432 days; range from 151 days to 1146 days), the incidence of clinical events occurred in 22 patients (27.2%) in total. In a multivariate analysis, a high DFT was the only predictive factor for the incidence of the clinical outcome (OR 4.54, 95% CI 1.03-21.9, P = 0.045).


Asunto(s)
Desfibriladores Implantables/normas , Cardiopatías/terapia , Adulto , Anciano , Anciano de 80 o más Años , Dispositivos de Terapia de Resincronización Cardíaca/normas , Dispositivos de Terapia de Resincronización Cardíaca/estadística & datos numéricos , Desfibriladores Implantables/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
13.
Circ J ; 80(1): 85-92, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26581624

RESUMEN

BACKGROUND: Subcutaneous implantable cardiac defibrillator (S-ICD) systems have a lower invasiveness than traditional ICD systems, and expand the indications of ICD implantations. The S-ICD standard defibrillation shock output energy, however, is approximately 4 times that of the traditional ICD system. This raises concern about the efficacy of the defibrillation and myocardial injury. In this study, we investigated the defibrillation efficacy and myocardial injury with S-ICD systems based on computer simulations. METHODS AND RESULTS: First, computer simulations were performed based on the S-ICD system configurations proposed in a previous study. Furthermore, simulations were performed by placing the lead at the left or right parasternal margin and the pulse generator in the superior and inferior positions (0-10 cm) of the recommended site. The simulated defibrillation threshold (DFT) for the 4 S-ICD system configurations were 30.1, 41.6, 40.6, and 32.8 J, which were generally similar to the corresponding clinical results of 33.5, 40.4, 40.1, and 34.3 J. CONCLUSIONS: The simulated DFT were generally similar to their clinical counterparts. In the simulation, the S-ICD system had a higher DFT but relatively less severe myocardial injury compared with the traditional ICD system. Further, the lead at the right parasternal margin may correspond to a lower DFT and cause less myocardial injury.


Asunto(s)
Simulación por Computador , Desfibriladores Implantables/efectos adversos , Lesiones Cardíacas/fisiopatología , Corazón/fisiopatología , Modelos Cardiovasculares , Lesiones Cardíacas/etiología , Humanos
14.
Circ J ; 80(4): 878-86, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26888267

RESUMEN

BACKGROUND: To reduce myocardial damage caused by implantable cardioverter defibrillator (ICD) shock, the left axilla was studied as an alternative pulse generator implantation site, and compared with the traditional implantation site, the left anterior chest. METHODS AND RESULTS: Computer simulation was used to study the defibrillation conduction pattern and estimate the simulated defibrillation threshold (DFT) and myocardial damage when pulse generators were placed in the left axilla and left anterior chest, respectively; pulse generators were also newly implanted in the left axilla (n=30) and anterior chest (n=40) to compare the corresponding DFT. On simulation, when ICD generators were implanted in the left axilla, compared with the left anterior chest, the whole heart may be defibrillated with a lower defibrillation energy (left axilla 6.4 J vs. left anterior chest 12.0 J) and thus the proportion of cardiac myocardial damage may be reduced (2.1 vs. 4.2%). Clinically, ventricular fibrillation was successfully terminated with a defibrillation output ≤5 J in 86.7% (26/30) of the left axillary group, and in 27.5% (11/40) of the left anterior group (P<0.001). CONCLUSIONS: Clinically and theoretically, the left axilla was shown to be an improved ICD implantation site that may reduce DFT and lessen myocardial damage due to shock. Lower DFT also facilitates less myocardial damage, as a result of the lower shock required.


Asunto(s)
Axila , Simulación por Computador , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica , Modelos Cardiovasculares , Miocardio/patología , Fibrilación Ventricular , Adulto , Anciano , Anciano de 80 o más Años , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Ventricular/patología , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/terapia
15.
Pacing Clin Electrophysiol ; 38(1): 35-41, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25229318

RESUMEN

BACKGROUND: Pacemaker generators are routinely implanted in the anterior chest. However, where to place the generator may need to be considered from the mental, functional, and cosmetic standpoints. METHODS: In this study, we performed the left axillary pacemaker generator implantation with a direct puncture of the left axillary vein in 40 consecutive patients, and evaluated the late safety and efficacy of this implantation. Complications, changes in the lead sensing, pacing threshold, and impedance were used as safety indexes for a mean follow-up of 3.4 years. In addition, the efficacy was also evaluated by comparing their questionnaire survey results to 119 patients in a control group of anterior chest implantation. RESULTS: Lead dislodgements were observed in two patients of the experiment group. There were no migrations of generators from the implantation site or abnormal variations in the pacing threshold, lead sensing, or impedance. In the left anterior chest and left axillary groups, 85% and 10% of the patients were worried about an external impact, 80% and 25% were worried about electromagnetic interference, and 68% and 0% answered that the pacemaker implantation site was noticeable, respectively. Apparently, more patients had a sense of security and cosmetic satisfaction with the left axillary implantation. CONCLUSION: The left axillary generator implantations may reduce the mental burden and cause no safety concerns, and may be performed if functional or cosmetic outcomes are required.


Asunto(s)
Vena Axilar/cirugía , Marcapaso Artificial , Implantación de Prótesis/métodos , Punciones , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
16.
J Arrhythm ; 40(3): 489-500, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939759

RESUMEN

Background: Patients with atrial fibrillation (AF) and heart failure (HF) have high stroke risk owing to left atrial dysfunction. However, anticoagulation is a concern in patients with high bleeding risk. We aimed to identify independent predictors of stroke in HF patients with AF. Methods: We retrospectively examined 320 patients (mean age 79 ± 12 years, 163 women) hospitalized with acute HF complicated by AF between January 2014 and December 2018. Patients were followed from admission until ischemic stroke or systemic embolism (SSE) onset or death or were censored at the last contact date or September 2023. Results: SSE occurred in 40 patients (median follow-up of 528 days). Multivariate Cox regression analysis identified age (hazard ratio [HR] 1.04, 95% confidence interval [CI] 1.00-1.07, p = .034), direct oral anticoagulant (DOAC) use (HR 0.26, 95% CI 0.11-0.60, p = .002), and early diastolic peak flow velocity to early diastolic peak annular velocity (E/e'; HR 1.05, 95% CI 1.02-1.08, p < .001) to be independent predictors of SSE, whereas left atrial reservoir strain was not. After determining an appropriate E/e' cutoff by receiver-operating characteristic curve analysis and adjusting the multivariate Cox model, E/e' ≥17.5 (HR 3.30, 95% CI 1.56-6.83, p = .001) independently predicted SSE. The results were consistent with no interaction in the subanalysis except for gender. Conclusion: Elderly patients not on DOACs with elevated E/e' may be at higher risk of stroke, suggesting that DOACs should be the first choice for patients with elevated E/e' and aggressive additional prophylaxis and careful follow-up are needed.

18.
Nihon Rinsho ; 71(1): 54-9, 2013 Jan.
Artículo en Japonés | MEDLINE | ID: mdl-23631172

RESUMEN

Electrophysiological study should be done in patients who suppose to undergo the treatment including pulmonary vein isolation using catheter ablation for atrial fibrillation. The purpose of the electrophysiological study consist with confirmation of the induction and the origin of atrial fibrillation, and with recognition of electrical potential and arrhythmogenic substrate for maintenance of atrial fibrillation. The shortening and irregularity of the refractory periods and prolongation of conduction time are important factor in occurrence of atrial fibrillation. Moreover, the complex fractionated atrial electrograms(CFAE) and ganglionated plexus(GP) play an important role in maintenance of atrial fibrillation. As it is indispensable to record and distinguish the electrical potential of atrium and pulmonary vein for the ablation of atrial fibrillation, every physician who is concerned in the catheter ablation requires accustoming to these potentials.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Humanos , Venas Pulmonares/fisiopatología
19.
Vaccines (Basel) ; 11(5)2023 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-37243038

RESUMEN

A 45-year-old man who had received his second mRNA COVID-19 vaccination one week earlier was presented to the emergency department with chest discomfort. Therefore, we suspected post-vaccination myocarditis; however, the patient showed no signs of myocarditis. After 2 weeks, he revisited the hospital complaining of palpitations, hand tremors, and weight loss. The patient exhibited high free thyroxine (FT4) (6.42 ng/dL), low thyroid-stimulating hormone (TSH) (<0.01 µIU/mL), and high TSH receptor antibody (17.5 IU/L) levels, and was diagnosed with Graves' disease. Thiamazole was administered, and the patient's FT4 levels normalized after 30 days. One year later, the patient's FT4 is stable; however, their TSH receptor antibodies have not become negative and thiamazole has continued. This is the first case report to follow the course of Graves' disease one year after mRNA COVID-19 vaccination.

20.
J Cardiol Cases ; 26(4): 264-267, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36187317

RESUMEN

Percutaneous mitral annuloplasty is widely used for the treatment of functional mitral regurgitation. There are limited imaging options to guide MitraClip procedure (Abbott Vascular, Santa Clara, CA, USA) in patients intolerant to transesophageal echocardiography. We describe a case using a 3-dimensional electro anatomical mapping system to facilitate the successful MitraClip procedure. Learning objectives: There are situations in which percutaneous mitral valve repair (MitraClip) for mitral regurgitation is difficult to perform under transesophageal echocardiography due to esophageal disease.3D mapping system may be useful when performing MitraClip under transthoracic echocardiography.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA