RESUMEN
Pushing selected information to clinicians, as opposed to the traditional method of clinicians pulling information from an electronic medical record, has the potential to improve care. A digital notification platform was designed by clinicians and implemented in a tertiary hospital to flag dysglycaemia. There were 112 patients included in the study, and the post-implementation group demonstrated lower rates of dysglycaemia (2.5% vs 1.1%, P = 0.038). These findings raise considerations for information delivery methods for multiple domains in contemporary healthcare.
Asunto(s)
Registros Electrónicos de Salud , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Glucemia/análisis , Centros de Atención TerciariaRESUMEN
The AMnO2 delafossites (A = Na, Cu) are model frustrated antiferromagnets, with triangular layers of Mn3+ spins. At low temperatures (TN = 65 K), a C2/m â P1Ì transition is found in CuMnO2, which breaks frustration and establishes magnetic order. In contrast to this clean transition, A = Na only shows short-range distortions at TN. Here, we report a systematic crystallographic, spectroscopic, and theoretical investigation of CuMnO2. We show that, even in stoichiometric samples, nonzero anisotropic Cu displacements coexist with magnetic order. Using X-ray/neutron diffraction and Raman scattering, we show that high pressures act to decouple these degrees of freedom. This manifests as an isostuctural phase transition at â¼10 GPa, with a reversible collapse of the c-axis. This is shown to be the high-pressure analogue of the c-axis negative thermal expansion seen at ambient pressure. Density functional theory (DFT) simulations confirm that dynamical instabilities of the Cu+ cations and edge-shared MnO6 layers are intertwined at ambient pressure. However, high pressure selectively activates the former, before an eventual predicted reemergence of magnetism at the highest pressures. Our results show that the lattice dynamics and local structure of CuMnO2 are quantitatively different from nonmagnetic Cu delafossites and raise questions about the role of intrinsic inhomogeneity in frustrated antiferromagnets.
RESUMEN
Dramatic volume collapses under pressure are fundamental to geochemistry and of increasing importance to fields as diverse as hydrogen storage and high-temperature superconductivity. In transition metal materials, collapses are usually driven by so-called spin-state transitions, the interplay between the single-ion crystal field and the size of the magnetic moment. Here we show that the classical S = 5/2 mineral hauerite (MnS2) undergoes an unprecedented (ΔV ~ 22%) collapse driven by a conceptually different magnetic mechanism. Using synchrotron X-ray diffraction we show that cold compression induces the formation of a disordered intermediate. However, using an evolutionary algorithm we predict a new structure with edge-sharing chains. This is confirmed as the thermodynamic ground state using in situ laser heating. We show that magnetism is globally absent in the new phase, as low-spin quantum S = 1/2 moments are quenched by dimerization. Our results show how the emergence of metal-metal bonding can stabilize giant spin-lattice coupling in Earth's minerals.
RESUMEN
Electroencephalography (EEG) is an established diagnostic tool with important implications for the clinical management of patients with epilepsy or nonepileptic attack disorder. Different types of long-term EEG recording strategies have been developed over the last decades, including the widespread use of ambulatory electroencephalography (AEEG), which holds great potential in terms of both clinical usefulness and cost-effectiveness. In this paper, we present the results of a systematic review of the scientific literature on the use of AEEG in the diagnosis of epilepsy and nonepileptic attacks in adult patients. Taken together, our findings confirmed that AEEG is a useful diagnostic tool in patients with equivocal findings on routine EEG studies and influences management decisions in the majority of studies. There is evidence that AEEG is also more likely to capture events than sleep-deprived EEG; however, there are currently insufficient data available to compare the diagnostic utility of modern AEEG technology with inpatient video-telemetry. Further research on the combined use of AEEG and home-video recording is, therefore, warranted.
Asunto(s)
Atención Ambulatoria/métodos , Electroencefalografía/métodos , Epilepsia/diagnóstico , Pacientes Ambulatorios , Convulsiones/diagnóstico , Adulto , Análisis Costo-Beneficio , Humanos , Privación de Sueño , Grabación en Video/métodosAsunto(s)
Taponamiento Cardíaco , Ablación por Catéter , Pericarditis , Venas Pulmonares , Taponamiento Cardíaco/diagnóstico por imagen , Taponamiento Cardíaco/etiología , Humanos , Pericarditis/diagnóstico por imagen , Pericarditis/etiología , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugíaRESUMEN
BACKGROUND: Biological age can be predicted using artificial intelligence (AI) trained on electrocardiograms (ECGs), which is prognostic for mortality and cardiovascular events. OBJECTIVE: We developed an AI model to predict age from an ECG and compared baseline characteristics to identify determinants of advanced biological age. METHODS: An AI model was trained on ECGs from cardiology inpatients aged 20-90 years. AI analysis used a convolutional neural network with data divided in an 80:20 ratio (development/internal validation), with external validation undertaken using data from the UK Biobank. Performance and subgroup comparison measures included correlation, difference, and mean absolute difference. RESULTS: A total of 63,246 patients with 353,704 total ECGs were included. In internal validation, the correlation coefficient was 0.72, with a mean absolute difference between chronological age and AI-predicted age of 9.1 years. The same model performed similarly in external validation. In patients aged 20-29 years, AI-ECG-predicted biological age was greater than chronological age by a mean of 14.3 ± 0.2 years. In patients aged 80-89 years, biological age was lower by a mean of 10.5 ± 0.1 years. Women were biologically younger than men by a mean of 10.7 months (P = .023), and patients with a single ECG were biologically 1.0 years younger than those with multiple ECGs (P < .0001). CONCLUSION: There are significant between-group differences in AI-ECG-predicted biological age for patient subgroups. Biological age was greater than chronological age in young hospitalized patients and lower than chronological age in older hospitalized patients. Women and patients with a single ECG recorded were biologically younger than men and patients with multiple recorded ECGs.
RESUMEN
Background: Inpatient monitoring is recommended for sotalol initiation. Objective: The purpose of this study was to assess the safety of outpatient sotalol commencement. Methods: This is a multicenter, retrospective, observational study of patients initiated on sotalol in an outpatient setting. Serial electrocardiogram monitoring at day 3, day 7, 1 month, and subsequently as clinically indicated was performed. Corrected QT (QTc) interval and clinical events were evaluated. Results: Between 2008 and 2023, 880 consecutive patients who were commenced on sotalol were evaluated. Indications were atrial fibrillation/flutter in 87.3% (n = 768), ventricular arrhythmias in 9.9% (n = 87), and other arrhythmias in 2.8% (n = 25). The daily dosage at initiation was 131.0 ± 53.2 mg/d. The QTc interval increased from baseline (431 ± 32 ms) to 444 ± 37 ms (day 3) and 440 ± 33 ms (day 7) after sotalol initiation (P < .001). Within the first week, QTc prolongation led to the discontinuation of sotalol in 4 and dose reduction in 1. No ventricular arrhythmia, syncope, or death was observed during the first week. Dose reduction due to asymptomatic bradycardia occurred in 3 and discontinuation due to dyspnea in 3 within the first week. Overall, 1.1% developed QTc prolongation (>500 ms/>25% from baseline); 4 within 3 days, 1 within 1 week, 4 within 60 days, and 1 after >3 years. Discontinuation of sotalol due to other adverse effects occurred in 41 patients within the first month of therapy. Conclusion: Sotalol initiation in an outpatient setting with protocolized follow-up is safe, with no recorded sotalol-related mortality, ventricular arrhythmias, or syncope. There was a low incidence of significant QTc prolongation necessitating discontinuation within the first month of treatment. Importantly, we observed a small incidence of late QT prolongation, highlighting the need for vigilant outpatient surveillance of individuals on sotalol.
RESUMEN
Weekend discharges occur less frequently than discharges on weekdays, contributing to hospital congestion. Artificial intelligence algorithms have previously been derived to predict which patients are nearing discharge based upon ward round notes. In this implementation study, such an artificial intelligence algorithm was coupled with a multidisciplinary discharge facilitation team on weekend shifts. This approach was implemented in a tertiary hospital, and then compared to a historical cohort from the same time the previous year. There were 3990 patients included in the study. There was a significant increase in the proportion of inpatients who received weekend discharges in the intervention group compared to the control group (median 18%, IQR 18-20%, vs median 14%, IQR 12% to 17%, P = 0.031). There was a corresponding higher absolute number of weekend discharges during the intervention period compared to the control period (P = 0.025). The studied intervention was associated with an increase in weekend discharges and economic analyses support this approach as being cost-effective. Further studies are required to examine the generalizability of this approach to other centers.
Asunto(s)
Inteligencia Artificial , Alta del Paciente , Humanos , Inteligencia Artificial/tendencias , Alta del Paciente/estadística & datos numéricos , Femenino , Masculino , Persona de Mediana Edad , Grupo de Atención al Paciente , Anciano , Factores de Tiempo , AlgoritmosRESUMEN
BACKGROUND: Fidelity of electrogram sensing may reduce false alerts from an insertable cardiac monitor (ICM). OBJECTIVE: The purpose of this study was to assess the effect of vector length, implant angle, and patient factors on electrogram sensing using surface electrocardiogram (ECG) mapping. METHODS: Twelve separate precordial single-lead surface ECGs were acquired from 150 participants at 2 interelectrode distances (75 and 45 mm), at 3 vector angles (vertical, oblique, and horizontal), and in 2 postures (upright and supine). A subset of 50 patients also received a clinically indicated ICM implant in 1:1 ratio (Reveal LINQ [Medtronic, Minneapolis, MN]/BIOMONITOR III [Biotronik, Berlin, Germany]). All ECGs and ICM electrograms were analyzed by blinded investigators using DigitizeIt software (V2.3.3, Braunschweig, Germany). The P-wave visibility threshold was set at > 0.015 mV. Logistic regression was used to identify factors affecting P-wave amplitude. RESULTS: A total of 1800 tracings from 150 participants (44.5% [n = 68] female; median age 59 [35-73] years) were assessed. The median P- and R-wave amplitudes were 45% and 53% larger with vector lengths of 75 and 45 mm, respectively (P < .001 for both). The oblique orientation yielded the best P- and R-wave amplitudes, while posture change did not affect P-wave amplitude. Mixed effects modeling found that visible P-waves occur more frequently with a vector length of 75 mm than with 45 mm (86% vs 75%, respectively; P < .0001). A longer vector length improved both P-wave amplitude and visibility in all body mass index categories. There was a moderate correlation of P- and R-wave amplitudes from the ICM electrograms to those from surface ECG recordings (intraclass correlation coefficient 0.74 and 0.80, respectively). CONCLUSION: Longer vector length and oblique implant angle yielded the best electrogram sensing and are relevant considerations for ICM implantation procedures.
Asunto(s)
Electrocardiografía Ambulatoria , Electrocardiografía , Humanos , Femenino , Persona de Mediana Edad , Electrocardiografía Ambulatoria/métodos , Electrocardiografía/métodos , Prótesis e Implantes , Programas Informáticos , AlemaniaRESUMEN
At variance with what was previously reported, Mn2(CO)10 does not transform its conformation from staggered to eclipsed in the high pressure crystal form. X-ray powder diffraction, DFT calculations and Raman spectroscopy show that the staggered conformation is retained. Instead, a rotation and a translation of the Mn(CO)5 pyramidal units produce an "off-axis" and rather shorter Mn-Mn bond.