Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 50(4): 1238-1250, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30770603

RESUMEN

BACKGROUND: Chemical exchange saturation transfer (CEST) can potentially support cancer imaging with metabolically derived information. Multiparametric prostate MRI has improved diagnosis but may benefit from additional information to reduce the need for biopsies. PURPOSE: To optimize an acquisition and postprocessing protocol for 3.0 T multipool CEST analysis of prostate data and evaluate the repeatability of the technique. STUDY TYPE: Prospective. SUBJECTS: Five healthy volunteers (age range: 24-47 years; median age: 28 years) underwent two sessions (interval range: 7-27 days; median interval: 20 days) and two biopsy-proven prostate cancer patients were evaluated once. Patient 1 (71 years) had a Gleason 3 + 4 transition zone (TZ) tumor and patient 2 (55 years) had a Gleason 4 + 3 peripheral zone (PZ) tumor. FIELD STRENGTH: 3.0 T. Sequences run: T2 -weighted turbo-spin-echo (TSE); diffusion-weighted imaging; CEST; WASABI (for B0 determination). ASSESSMENT: Saturation, readout, and fit-model parameters were optimized to maximize in vivo amide and nuclear Overhauser effect (NOE) signals. Repeatability (intrasession and intersession) was evaluated in healthy volunteers. Subsequently, preliminary evaluation of signal differences was made in patients. Regions of interest were drawn by two post-FRCR board-certified readers, both with over 5 years of experience in multiparametric prostate MRI. STATISTICAL TESTS: Repeatability was assessed using Bland-Altman analysis, coefficient of variation (CV), and 95% limits of agreement (LOA). Statistical significance of CEST contrast was calculated using a nonparametric Mann-Whitney U-test. RESULTS: The optimized saturation scheme was found to be 60 sinc-Gaussian pulses with 40 msec pulse duration, at 50% duty-cycle with continuous-wave pulse equivalent B1 power (B1CWPE ) of 0.92 µT. The magnetization transfer (MT) contribution to the fit-model was centered at -1.27 ppm. Intersession coefficients of variation (CVs) of the amide, NOE, and magnetization transfer (MT) and asymmetric magnetization transfer ratio (MTRasym ) signals of 25%, 23%, 18%, and 200%, respectively, were observed. Fit-metric and MTRasym CVs agreed between readers to within 4 and 10 percentage points, respectively. DATA CONCLUSION: Signal differences of 0.03-0.10 (17-43%) detectable depending upon pool, with MT the most repeatable (signal difference of 17-22% detectable). LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1238-1250.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Adulto , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA