Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 546
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Biol Chem ; 300(1): 105517, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38042487

RESUMEN

Amide-to-ester substitutions are used to study the role of the amide bonds of the protein backbone in protein structure, function, and folding. An amber suppressor tRNA/synthetase pair has been reported for incorporation of p-hydroxy-phenyl-L-lactic acid (HPLA), thereby introducing ester substitution at tyrosine residues. However, the application of this approach was limited due to the low yields of the modified proteins and the high cost of HPLA. Here we report the in vivo generation of HPLA from the significantly cheaper phenyl-L-lactic acid. We also construct an optimized plasmid with the HPLA suppressor tRNA/synthetase pair that provides higher yields of the modified proteins. The combination of the new plasmid and the in-situ generation of HPLA provides a facile and economical approach for introducing tyrosine ester substitutions. We demonstrate the utility of this approach by introducing tyrosine ester substitutions into the K+ channel KcsA and the integral membrane enzyme GlpG. We introduce the tyrosine ester in the selectivity filter of the M96V mutant of the KcsA to probe the role of the second ion binding site in the conformation of the selectivity filter and the process of inactivation. We use tyrosine ester substitutions in GlpG to perturb backbone H-bonds to investigate the contribution of these H-bonds to membrane protein stability. We anticipate that the approach developed in this study will facilitate further investigations using tyrosine ester substitutions.


Asunto(s)
Ésteres , Fenilpropionatos , Tirosina , Ésteres/química , Enlace de Hidrógeno , Proteínas/química , Sitios de Unión , ARN de Transferencia , Amidas/química , Ácido Láctico , Ligasas
2.
Proc Natl Acad Sci U S A ; 119(19): e2121653119, 2022 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-35507872

RESUMEN

Glutamate transporters carry out the concentrative uptake of glutamate by harnessing the ionic gradients present across cellular membranes. A central step in the transport mechanism is the coupled binding of Na+ and substrate. The sodium coupled Asp transporter, GltPh is an archaeal homolog of glutamate transporters that has been extensively used to probe the transport mechanism. Previous studies have shown that hairpin-2 (HP2) functions as the extracellular gate for the aspartate binding site and plays a key role in the coupled binding of sodium and aspartate to GltPh. The binding sites for three Na+ ions (Na1-3) have been identified in GltPh, but the specific roles of the individual Na+ sites in the binding process have not been elucidated. In this study, we developed assays to probe Na+ binding to the Na1 and Na3 sites and to monitor the conformational switch in the NMDGT motif. We used these assays along with a fluorescence assay to monitor HP2 movement and EPR spectroscopy to show that Na+ binding to the Na3 site is required for the NMDGT conformational switch while Na+ binding to the Na1 site is responsible for the partial opening of HP2. Complete opening of HP2 requires the conformational switch of the NMDGT motif and therefore Na+ binding to both the Na1 and the Na3 sites. Based on our studies, we also propose an alternate pathway for the coupled binding of Na+ and Asp.


Asunto(s)
Sistema de Transporte de Aminoácidos X-AG , Sodio , Sistema de Transporte de Aminoácidos X-AG/química , Sitios de Unión , Ácido Glutámico/metabolismo , Iones/metabolismo , Sodio/metabolismo
3.
J Am Chem Soc ; 146(2): 1543-1553, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38181505

RESUMEN

Water inside biological ion channels regulates the key properties of these proteins, such as selectivity, ion conductance, and gating. In this article, we measure the picosecond spectral diffusion of amide I vibrations of an isotope-labeled KcsA potassium channel using two-dimensional infrared (2D IR) spectroscopy. By combining waiting time (100-2000 fs) 2D IR measurements of the KcsA channel including 13C18O isotope-labeled Val76 and Gly77 residues with molecular dynamics simulations, we elucidated the site-specific dynamics of water and K+ ions inside the selectivity filter of KcsA. We observe inhomogeneous 2D line shapes with extremely slow spectral diffusion. Our simulations quantitatively reproduce the experiments and show that water is the only component with any appreciable dynamics, whereas K+ ions and the protein are essentially static on a picosecond timescale. By analyzing simulated and experimental vibrational frequencies, we find that water in the selectivity filter can be oriented to form hydrogen bonds with adjacent or nonadjacent carbonyl groups with the reorientation timescales being three times slower and comparable to that of water molecules in liquid, respectively. Water molecules can reside in the cavity sufficiently far from carbonyls and behave essentially like "free" gas-phase-like water with fast reorientation times. Remarkably, no interconversion between these configurations was observed on a picosecond timescale. These dynamics are in stark contrast with liquid water, which remains highly dynamic even in the presence of ions at high concentrations.

4.
Radiology ; 310(3): e231986, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38501953

RESUMEN

Photon-counting CT (PCCT) is an emerging advanced CT technology that differs from conventional CT in its ability to directly convert incident x-ray photon energies into electrical signals. The detector design also permits substantial improvements in spatial resolution and radiation dose efficiency and allows for concurrent high-pitch and high-temporal-resolution multienergy imaging. This review summarizes (a) key differences in PCCT image acquisition and image reconstruction compared with conventional CT; (b) early evidence for the clinical benefit of PCCT for high-spatial-resolution diagnostic tasks in thoracic imaging, such as assessment of airway and parenchymal diseases, as well as benefits of high-pitch and multienergy scanning; (c) anticipated radiation dose reduction, depending on the diagnostic task, and increased utility for routine low-dose thoracic CT imaging; (d) adaptations for thoracic imaging in children; (e) potential for further quantitation of thoracic diseases; and (f) limitations and trade-offs. Moreover, important points for conducting and interpreting clinical studies examining the benefit of PCCT relative to conventional CT and integration of PCCT systems into multivendor, multispecialty radiology practices are discussed.


Asunto(s)
Radiología , Tomografía Computarizada por Rayos X , Niño , Humanos , Procesamiento de Imagen Asistido por Computador , Fotones
5.
J Fish Dis ; 47(5): e13921, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38270561

RESUMEN

The present study investigates molecular-based PCR techniques to estimate the prevalence of fish pathogens in southwest Mexico where recurrent mortality in the tilapia cultures has been observed. Sample of internal organs and lesions of Nile tilapia were taken and analysed in 2018, 2019, 2020 and 2022 to detect bacterial pathogens using PCR. No samples were taken in 2021 due to the COVID-19 pandemic. The real-time PCR conditions were optimized to allow a qualitative reliable detection of the bacteria from fixed fish tissue. A total of 599 pond- and cage-cultured tilapia from the southwestern Mexican Pacific (Guerrero, Oaxaca and Chiapas states) were analysed. In this tropical region, during 2018 and 2019 water temperatures of the tilapia cultures were generally with the optimal range to grow Nile tilapia, although extreme values were recorded on some farms. Most of the tilapia sampled were apparently healthy. No Francisella sp. was detected in any sample, and Staphylococcus sp. was the most prevalent (from 0% to 64%) bacteria from the three states over time. Low prevalence of Aeromonas sp. was found, from 0% to 4.3%, although the fish pathogen Aeromonas dhakensis was not detected. Sterptococcus iniae was only detected in Chiapas in 2019 at a low prevalence (1.4%), while the major tilapia pathogen S. agalactiae was detected at a high prevalence (from 0% to 59%) in the three Mexican states. This is the first detection of these pathogenic bacteria in rural farms using real-time PCR and constitutes a great risk for tilapia aquaculture in Mexico, as well as a potential dispersion of these pathogens to other aquaculture areas.


Asunto(s)
Cíclidos , Enfermedades de los Peces , Tilapia , Animales , Cíclidos/microbiología , Reacción en Cadena en Tiempo Real de la Polimerasa/veterinaria , México/epidemiología , Prevalencia , Pandemias , Enfermedades de los Peces/microbiología , Acuicultura
6.
Skeletal Radiol ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937291

RESUMEN

OBJECTIVE: To develop a whole-body low-dose CT (WBLDCT) deep learning model and determine its accuracy in predicting the presence of cytogenetic abnormalities in multiple myeloma (MM). MATERIALS AND METHODS: WBLDCTs of MM patients performed within a year of diagnosis were included. Cytogenetic assessments of clonal plasma cells via fluorescent in situ hybridization (FISH) were used to risk-stratify patients as high-risk (HR) or standard-risk (SR). Presence of any of del(17p), t(14;16), t(4;14), and t(14;20) on FISH was defined as HR. The dataset was evenly divided into five groups (folds) at the individual patient level for model training. Mean and standard deviation (SD) of the area under the receiver operating curve (AUROC) across the folds were recorded. RESULTS: One hundred fifty-one patients with MM were included in the study. The model performed best for t(4;14), mean (SD) AUROC of 0.874 (0.073). The lowest AUROC was observed for trisomies: AUROC of 0.717 (0.058). Two- and 5-year survival rates for HR cytogenetics were 87% and 71%, respectively, compared to 91% and 79% for SR cytogenetics. Survival predictions by the WBLDCT deep learning model revealed 2- and 5-year survival rates for patients with HR cytogenetics as 87% and 71%, respectively, compared to 92% and 81% for SR cytogenetics. CONCLUSION: A deep learning model trained on WBLDCT scans predicted the presence of cytogenetic abnormalities used for risk stratification in MM. Assessment of the model's performance revealed good to excellent classification of the various cytogenetic abnormalities.

7.
J Am Chem Soc ; 145(33): 18529-18537, 2023 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-37578394

RESUMEN

The potassium ion (K+) configurations of the selectivity filter of the KcsA ion channel protein are investigated with two-dimensional infrared (2D IR) spectroscopy of amide I vibrations. Single 13C-18O isotope labels are used, for the first time, to selectively probe the S1/S2 or S2/S3 binding sites in the selectivity filter. These binding sites have the largest differences in ion occupancy in two competing K+ transport mechanisms: soft-knock and hard-knock. According to the former, water molecules alternate between K+ ions in the selectivity filter while the latter assumes that K+ ions occupy the adjacent sites. Molecular dynamics simulations and computational spectroscopy are employed to interpret experimental 2D IR spectra. We find that in the closed conductive state of the KcsA channel, K+ ions do not occupy adjacent binding sites. The experimental data is consistent with simulated 2D IR spectra of soft-knock ion configurations. In contrast, the simulated spectra for the hard-knock ion configurations do not reproduce the experimental results. 2D IR spectra of the hard-knock mechanism have lower frequencies, homogeneous 2D lineshapes, and multiple peaks. In contrast, ion configurations of the soft-knock model produce 2D IR spectra with a single peak at a higher frequency and inhomogeneous lineshape. We conclude that under equilibrium conditions, in the absence of transmembrane voltage, both water and K+ ions occupy the selectivity filter of the KcsA channel in the closed conductive state. The ion configuration is central to the mechanism of ion transport through potassium channels.


Asunto(s)
Canales de Potasio , Potasio , Canales de Potasio/química , Potasio/química , Espectrofotometría Infrarroja , Isótopos , Iones/química , Agua/metabolismo , Proteínas Bacterianas/química , Conformación Proteica
8.
Radiology ; 308(2): e222217, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37526541

RESUMEN

In recent years, deep learning (DL) has shown impressive performance in radiologic image analysis. However, for a DL model to be useful in a real-world setting, its confidence in a prediction must also be known. Each DL model's output has an estimated probability, and these estimated probabilities are not always reliable. Uncertainty represents the trustworthiness (validity) of estimated probabilities. The higher the uncertainty, the lower the validity. Uncertainty quantification (UQ) methods determine the uncertainty level of each prediction. Predictions made without UQ methods are generally not trustworthy. By implementing UQ in medical DL models, users can be alerted when a model does not have enough information to make a confident decision. Consequently, a medical expert could reevaluate the uncertain cases, which would eventually lead to gaining more trust when using a model. This review focuses on recent trends using UQ methods in DL radiologic image analysis within a conceptual framework. Also discussed in this review are potential applications, challenges, and future directions of UQ in DL radiologic image analysis.


Asunto(s)
Aprendizaje Profundo , Radiología , Humanos , Incertidumbre , Procesamiento de Imagen Asistido por Computador
9.
Radiology ; 308(2): e230344, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37606571

RESUMEN

CT is one of the most widely used modalities for musculoskeletal imaging. Recent advancements in the field include the introduction of four-dimensional CT, which captures a CT image during motion; cone-beam CT, which uses flat-panel detectors to capture the lower extremities in weight-bearing mode; and dual-energy CT, which operates at two different x-ray potentials to improve the contrast resolution to facilitate the assessment of tissue material compositions such as tophaceous gout deposits and bone marrow edema. Most recently, photon-counting CT (PCCT) has been introduced. PCCT is a technique that uses photon-counting detectors to produce an image with higher spatial and contrast resolution than conventional multidetector CT systems. In addition, postprocessing techniques such as three-dimensional printing and cinematic rendering have used CT data to improve the generation of both physical and digital anatomic models. Last, advancements in the application of artificial intelligence to CT imaging have enabled the automatic evaluation of musculoskeletal pathologies. In this review, the authors discuss the current state of the above CT technologies, their respective advantages and disadvantages, and their projected future directions for various musculoskeletal applications.


Asunto(s)
Inteligencia Artificial , Tomografía Computarizada de Haz Cónico , Humanos , Tomografía Computarizada Cuatridimensional , Extremidad Inferior , Movimiento (Física)
10.
Radiology ; 306(1): 229-236, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36066364

RESUMEN

Background Photon-counting detector (PCD) CT and deep learning noise reduction may improve spatial resolution at lower radiation doses compared with energy-integrating detector (EID) CT. Purpose To demonstrate the diagnostic impact of improved spatial resolution in whole-body low-dose CT scans for viewing multiple myeloma by using PCD CT with deep learning denoising compared with conventional EID CT. Materials and Methods Between April and July 2021, adult participants who underwent a whole-body EID CT scan were prospectively enrolled and scanned with a PCD CT system in ultra-high-resolution mode at matched radiation dose (8 mSv for an average adult) at an academic medical center. EID CT and PCD CT images were reconstructed with Br44 and Br64 kernels at 2-mm section thickness. PCD CT images were also reconstructed with Br44 and Br76 kernels at 0.6-mm section thickness. The thinner PCD CT images were denoised by using a convolutional neural network. Image quality was objectively quantified in two phantoms and a randomly selected subset of participants (10 participants; median age, 63.5 years; five men). Two radiologists scored PCD CT images relative to EID CT by using a five-point Likert scale to detect findings reflecting multiple myeloma. The scoring for the matched reconstruction series was blinded to scanner type. Reader-averaged scores were tested with the null hypothesis of equivalent visualization between EID and PCD. Results Twenty-seven participants (median age, 68 years; IQR, 61-72 years; 16 men) were included. The blinded assessment of 2-mm images demonstrated improvement in viewing lytic lesions, intramedullary lesions, fatty metamorphosis, and pathologic fractures for PCD CT versus EID CT (P < .05 for all comparisons). The 0.6-mm PCD CT images with convolutional neural network denoising also demonstrated improvement in viewing all four pathologic abnormalities and detected one or more lytic lesions in 21 of 27 participants compared with the 2-mm EID CT images (P < .001). Conclusion Ultra-high-resolution photon-counting detector CT improved the visibility of multiple myeloma lesions relative to energy-integrating detector CT. © RSNA, 2022 Online supplemental material is available for this article.


Asunto(s)
Aprendizaje Profundo , Mieloma Múltiple , Adulto , Anciano , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Fotones , Tomografía Computarizada por Rayos X/métodos , Femenino
11.
Eur Radiol ; 33(8): 5309-5320, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37020069

RESUMEN

The X-ray detector is a fundamental component of a CT system that determines the image quality and dose efficiency. Until the approval of the first clinical photon-counting-detector (PCD) system in 2021, all clinical CT scanners used scintillating detectors, which do not capture information about individual photons in the two-step detection process. In contrast, PCDs use a one-step process whereby X-ray energy is converted directly into an electrical signal. This preserves information about individual photons such that the numbers of X-ray in different energy ranges can be counted. Primary advantages of PCDs include the absence of electronic noise, improved radiation dose efficiency, increased iodine signal and the ability to use lower doses of iodinated contrast material, and better spatial resolution. PCDs with more than one energy threshold can sort the detected photons into two or more energy bins, making energy-resolved information available for all acquisitions. This allows for material classification or quantitation tasks to be performed in conjunction with high spatial resolution, and in the case of dual-source CT, high pitch, or high temporal resolution acquisitions. Some of the most promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value. These include imaging of the inner ear, bones, small blood vessels, heart, and lung. This review describes the clinical benefits observed to date and future directions for this technical advance in CT imaging. KEY POINTS: • Beneficial characteristics of photon-counting detectors include the absence of electronic noise, increased iodine signal-to-noise ratio, improved spatial resolution, and full-time multi-energy imaging. • Promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value and applications requiring multi-energy data simultaneous with high spatial and/or temporal resolution. • Future applications of PCD-CT technology may include extremely high spatial resolution tasks, such as the detection of breast micro-calcifications, and quantitative imaging of native tissue types and novel contrast agents.


Asunto(s)
Compuestos de Yodo , Yodo , Humanos , Tomografía Computarizada por Rayos X/métodos , Tomógrafos Computarizados por Rayos X , Medios de Contraste , Fotones , Fantasmas de Imagen
12.
AJR Am J Roentgenol ; 220(4): 551-560, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36259593

RESUMEN

Photon-counting detector (PCD) CT has emerged as a novel imaging modality that represents a fundamental shift in the way that CT systems detect x-rays. After pre-clinical and clinical investigations showed benefits of PCD CT for a range of imaging tasks, the U.S. FDA in 2021 approved the first commercial PCD CT system for clinical use. The technologic features of PCD CT are particularly well suited for musculo-skeletal imaging applications. Advantages of PCD CT compared with conventional energy-integrating detector (EID) CT include smaller detector pixels and excellent geometric dose efficiency that enable imaging of large joints and central skeletal anatomy at ultrahigh spatial resolution; advanced multienergy spectral postprocessing that allows quantification of gout deposits and generation of virtual noncalcium images for visualization of bone edema; improved metal artifact reduction for imaging of orthopedic implants; and higher CNR and suppression of electronic noise. Given substantially improved cortical and trabecular detail, PCD CT images more clearly depict skeletal abnormalities, including fractures, lytic lesions, and mineralized tumor matrix. The purpose of this article is to review, by use of clinical examples comparing EID CT and PCD CT, the technical features of PCD CT and their associated impact on musculoskeletal imaging applications.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Rayos X
13.
Radiographics ; 43(5): e220158, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37022956

RESUMEN

Photon-counting detector (PCD) CT is an emerging technology that has led to continued innovation and progress in diagnostic imaging after it was approved by the U.S. Food and Drug Administration for clinical use in September 2021. Conventional energy-integrating detector (EID) CT measures the total energy of x-rays by converting photons to visible light and subsequently using photodiodes to convert visible light to digital signals. In comparison, PCD CT directly records x-ray photons as electric signals, without intermediate conversion to visible light. The benefits of PCD CT systems include improved spatial resolution due to smaller detector pixels, higher iodine image contrast, increased geometric dose efficiency to allow high-resolution imaging, reduced radiation dose for all body parts, multienergy imaging capabilities, and reduced artifacts. To recognize these benefits, diagnostic applications of PCD CT in musculoskeletal, thoracic, neuroradiologic, cardiovascular, and abdominal imaging must be optimized and adapted for specific diagnostic tasks. The diagnostic benefits and clinical applications resulting from PCD CT in early studies have allowed improved visualization of key anatomic structures and radiologist confidence for some diagnostic tasks, which will continue as PCD CT evolves and clinical use and applications grow. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material. See the invited commentary by Ananthakrishnan in this issue.


Asunto(s)
Yodo , Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Intensificación de Imagen Radiográfica/métodos , Fotones
14.
Skeletal Radiol ; 52(1): 1-8, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35835878

RESUMEN

This review illustrates the multimodality assessment of transfascial muscle and other soft tissue herniations of the extremities. Transfascial herniations of the extremities can develop from congenital or acquired disruptions of the deep fascia, resulting in herniation of the underlying muscle, nerve, or soft tissue tumor into the subcutaneous tissues. While most patients present with a painless subcutaneous nodule that may change in size with muscle activation, some may experience focal or diffuse extremity symptoms such as pain and paresthesias. Although the diagnosis may be clinically suspected, radiologic evaluation is useful for definitive diagnosis and characterization. Ultrasound is the preferred modality for initial workup through a focused and dynamic examination. Magnetic resonance imaging can be utilized for equivocal, complicated, and preoperative cases. Computed tomography is less useful in the evaluation of transfascial herniations in the extremities due to similarities in the attenuation between muscle and fascia, which can decrease the conspicuity of small defects.


Asunto(s)
Extremidades , Hernia , Humanos , Extremidades/diagnóstico por imagen , Fascia/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Músculos
15.
Skeletal Radiol ; 52(1): 91-98, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35980454

RESUMEN

BACKGROUND: Whole-body low-dose CT is the recommended initial imaging modality to evaluate bone destruction as a result of multiple myeloma. Accurate interpretation of these scans to detect small lytic bone lesions is time intensive. A functional deep learning) algorithm to detect lytic lesions on CTs could improve the value of these CTs for myeloma imaging. Our objectives were to develop a DL algorithm and determine its performance at detecting lytic lesions of multiple myeloma. METHODS: Axial slices (2-mm section thickness) from whole-body low-dose CT scans of subjects with biochemically confirmed plasma cell dyscrasias were included in the study. Data were split into train and test sets at the patient level targeting a 90%/10% split. Two musculoskeletal radiologists annotated lytic lesions on the images with bounding boxes. Subsequently, we developed a two-step deep learning model comprising bone segmentation followed by lesion detection. Unet and "You Look Only Once" (YOLO) models were used as bone segmentation and lesion detection algorithms, respectively. Diagnostic performance was determined using the area under the receiver operating characteristic curve (AUROC). RESULTS: Forty whole-body low-dose CTs from 40 subjects yielded 2193 image slices. A total of 5640 lytic lesions were annotated. The two-step model achieved a sensitivity of 91.6% and a specificity of 84.6%. Lesion detection AUROC was 90.4%. CONCLUSION: We developed a deep learning model that detects lytic bone lesions of multiple myeloma on whole-body low-dose CTs with high performance. External validation is required prior to widespread adoption in clinical practice.


Asunto(s)
Aprendizaje Profundo , Mieloma Múltiple , Osteólisis , Humanos , Mieloma Múltiple/diagnóstico por imagen , Mieloma Múltiple/patología , Algoritmos , Tomografía Computarizada por Rayos X/métodos
16.
Skeletal Radiol ; 52(9): 1651-1659, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36971838

RESUMEN

OBJECTIVE: The feasibility of low-dose photon-counting detector (PCD) CT to measure alpha and acetabular version angles of femoroacetabular impingement (FAI). MATERIAL AND METHODS: FAI patients undergoing an energy-integrating detector (EID) CT underwent an IRB-approved prospective ultra-high-resolution (UHR) PCD-CT between 5/2021 and 12/2021. PCD-CT was dose-matched to the EID-CT or acquired at 50% dose. Simulated 50% dose EID-CT images were generated. Two radiologists evaluated randomized EID-CT and PCD-CT images and measured alpha and acetabular version angles on axial image slices. Image quality (noise, artifacts, and visualization of cortex) and confidence in non-FAI pathology were rated on a 4-point scale (3 = adequate). Preference tests of standard dose PCD-CT, 50% dose PCD-CT, and 50% dose EID-CT relative to standard dose EID-CT were performed using Wilcoxon Rank test. RESULTS: 20 patients underwent standard dose EID-CT (~ CTDIvol, 4.5 mGy); 10 patients, standard dose PCD-CT (4.0 mGy); 10 patients, 50% PCD-CT (2.6 mGy). Standard dose EID-CT images were scored as adequate for diagnostic task in all categories (range 2.8-3.0). Standard dose PCD-CT images scored higher than the reference in all categories (range 3.5-4, p < 0.0033). Half-dose PCD-CT images also scored higher for noise and cortex visualization (p < 0.0033) and equivalent for artifacts and visualization of non-FAI pathology. Finally, simulated 50% EID-CT images scored lower in all categories (range 1.8-2.4, p < 0.0033). CONCLUSIONS: Dose-matched PCD-CT is superior to EID-CT for alpha angle and acetabular version measurement in the work up of FAI. UHR-PCD-CT enables 50% radiation dose reduction compared to EID while remaining adequate for the imaging task.


Asunto(s)
Pinzamiento Femoroacetabular , Humanos , Pinzamiento Femoroacetabular/diagnóstico por imagen , Estudios Prospectivos , Estudios de Factibilidad , Fotones , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Dosis de Radiación
17.
Emerg Radiol ; 30(4): 475-483, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37415035

RESUMEN

PURPOSE: Determine incidence of shoulder arthroplasty complications identified on computed tomography (CT). MATERIALS AND METHODS: Retrospective institutional database review of patients with shoulder arthroplasties who underwent CT between 01/2006-11/2021 at a tertiary academic referral center with subspecialized orthopedic shoulder surgeons. CT reports were reviewed for arthroplasty type and complication. Data were stratified and summarized. Associations between complications and arthroplasty types were determined with Chi-squared goodness of fit test. RESULTS: Eight hundred twelve CTs in 797 unique patients were included (438 (53.9%) females and 374 (46.1%) males; mean age 67 ± 11 years). There were 403 total shoulder arthroplasties (TSA), 317 reverse total shoulder arthroplasties (rTSA), and 92 hemiarthroplasties (HA). Complications were present in 527/812 (64.9%) and incidences were: loosening/aseptic osteolysis 36.9%, periprosthetic failure 21.6%, periprosthetic fracture 12.3%, periprosthetic dislocation 6.8%, joint/pseudocapsule effusion 5.9%, prosthetic failure 4.8%, infection 3.8%, and periprosthetic collection 2.1%. Complications per arthroplasty were: 305/403 (75.7%) TSAs, 176/317 (55.5%) rTSAs, and 46/92 (50%) HAs (p < 0.001). Periprosthetic fracture (20.8%), prosthetic dislocation (9.8%), and prosthetic failure (7.9%) were highest in rTSAs (p < 0.001, p < 0.013, p < 0.001, respectively). Loosening/aseptic osteolysis most frequent in TSAs (54.1%) (p < 0.001). Periprosthetic failure most frequent in HA (32.6%) (p < 0.001). Significant associations were identified with joint/pseudocapsule effusion and loosening/aseptic osteolysis (p = 0.04) and prosthetic dislocation (p < .001). CONCLUSION: In this single tertiary academic referral center cohort, the incidence of shoulder arthroplasty complication identified on CT was 64.9% and the most commonly occurring complication was loosening/aseptic osteolysis (36.9%). TSA had the highest incidence of complication (75.7%).

18.
J Appl Res Intellect Disabil ; 36(6): 1326-1336, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37620292

RESUMEN

BACKGROUND: While epilepsy can decrease quality of life and self-determination in individuals without intellectual disabilities, the impact of epilepsy on experienced self-determination in people with intellectual disabilities remains unclear. METHOD: We conducted semi-structured interviews with six adults (four men, two women) aged 30-61 with mild intellectual disabilities and drug-resistant epilepsy to investigate their experiences of self-determination. The data were analysed using Interpretative Phenomenological Analysis. RESULTS: Three main themes were identified: (A) I am a competent person with epilepsy; (B) My social needs: being accepted as I am and stability in relationships; and (C) Being in control. CONCLUSIONS: In this study, the impact of epilepsy on experienced self-determination of people with mild intellectual disabilities outweighs the influence of intellectual disabilities. Identity formation, friendships with peers, and autonomy support in risk management are identified as important topics in supporting this group.

19.
Eur Radiol ; 32(10): 7079-7086, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35689699

RESUMEN

OBJECTIVE: To evaluate ultra-high-resolution (UHR) imaging of large joints using an investigational photon-counting detector (PCD) CT. MATERIALS AND METHODS: Patients undergoing clinical shoulder or pelvis energy-integrating-detector (EID) CT exam were scanned using the UHR mode of the PCD-CT system. Axial EID-CT images (1-mm sections) and PCD-CT images (0.6-mm sections) were reconstructed using Br62/Br64 and Br76 kernels, respectively. Two musculoskeletal radiologists rated visualization of anatomic structures using a 5-point Likert scale. Wilcoxon rank-sum test was used for statistical analysis of reader scores, and paired t-test was used for comparing bone CT numbers and image noise from PCD-CT and EID-CT. RESULTS: Thirty-two patients (17 shoulders and 15 pelvis) were prospectively recruited for this feasibility study. Mean age for shoulder exams was 67.3 ± 15.5 years (11 females) and 47.2 ± 15.8 years (11 females) for pelvis exams. The mean volume CT dose index was lower on PCD-CT compared to that on EID-CT (shoulders: 18 mGy vs. 34 mGy, pelvis: 11.6 mGy vs. 16.7 mGy). PCD-CT was rated significantly better than EID-CT (p < 0.001) for anatomic-structure visualization. Trabecular delineation in shoulders (mean score = 4.24 ± 0.73) and femoroacetabular joint visualization in the pelvis (mean score = 3.67 ± 1.03) received the highest scores. PCD-CT demonstrated significant increase in bone CT number (p < 0.001) relative to EID-CT; no significant difference in image noise was found between PCD-CT and EID-CT. CONCLUSION: The evaluated PCD-CT system provided improved visualization of osseous structures in the shoulders and pelvises at a 31-47% lower radiation dose compared to EID-CT. KEY POINTS: • A full field-of-view PCD-CT with 0.151 mm × 0.176 mm detector pixel size (isocenter) facilitates bilateral, high-resolution imaging of shoulders and pelvis. • The evaluated investigational PCD-CT system was rated superior by two musculoskeletal radiologists for anatomic structure visualization in shoulders and pelvises despite a 31-47% lower radiation dose compared to EID-CT. • PCD-CT demonstrated significantly higher bone CT number compared to EID-CT, while no significant difference in image noise was observed between PCD-CT and EID-CT despite a 31-47% dose reduction on PCD-CT.


Asunto(s)
Fotones , Hombro , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Persona de Mediana Edad , Pelvis/diagnóstico por imagen , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos
20.
AJR Am J Roentgenol ; 218(6): 1041-1050, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35080455

RESUMEN

BACKGROUND. Dual-energy CT (DECT) allows noninvasive detection of monosodium urate (MSU) crystal deposits and has become incorporated into the routine clinical evaluation for gout at many institutions over the past decade. OBJECTIVE. The purpose of this study was to compare two time periods over the past decade in terms of radiologists' interpretations of DECT examinations performed for the evaluation of gout and subsequent clinical actions. METHODS. This retrospective study included 100 consecutive adult patients who underwent DECT to evaluate for gout in each of two periods (one beginning in March 2013 and one beginning in September 2019). Examinations performed in 2013 were conducted using a second-generation DECT scanner (80 kV [tube A] and 140 kV [tube B] with a 0.4-mm tin filter), and those performed in 2019 were conducted using a third-generation DECT scanner (80 kV [tube A] and 150 kV [tube B] with a 0.6-mm tin filter) that provides improved spectral separation. Original DECT reports were classified as positive, negative, or equivocal for MSU crystals indicative of gout. Joint aspirations occurring after the DECT examinations were recorded on the basis of findings from medical record review. A single radiologist performed a post hoc retrospective blinded image review, classifying examinations as positive, negative, or equivocal. RESULTS. In 2013, 44.0% of DECT examinations were interpreted as positive, 23.0% as negative, and 33.0% as equivocal; in 2019, 37.0% were interpreted as positive, 47.0% as negative, and 16.0% as equivocal (p < .001). The frequency of joint aspiration after DECT was 14.0% in 2013 versus 2.0% in 2019 (p = .002), and that after DECT examinations with negative interpretations was 17.4% in 2013 versus 2.1% in 2019 (p = .02). In post hoc assessment by a single radiologist, the distribution of interpretations in 2013 was positive in 49.0%, negative in 22.0%, and equivocal in 29.0%, and in 2019 it was positive in 39.0%, negative in 50.0%, and equivocal in 11.0% (p < .001). CONCLUSION. When DECT examinations performed for gout in 2013 and 2019 were compared, the frequency of equivocal interpretations was significantly lower in 2019, possibly in relation to interval technologic improvements. Negative examinations were less frequently followed by joint aspirations in 2019, possibly reflecting increasing clinical acceptance of the DECT results. CLINICAL IMPACT. The findings indicate an evolving role for DECT in the evaluation of gout after an institution's routine adoption of the technology for this purpose.


Asunto(s)
Gota , Ácido Úrico , Adulto , Gota/diagnóstico por imagen , Humanos , Estudios Retrospectivos , Estaño , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA