Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Spine J ; 30(8): 2091-2101, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34106349

RESUMEN

PURPOSE: The Global Burden of Diseases (GBD) Studies have estimated that low back pain is one of the costliest ailments worldwide. Subsequent to GBD publications, leadership of the four largest global spine societies agreed to form SPINE20. This article introduces the concept of SPINE20, the recommendations, and the future of this global advocacy group linked to G20 annual summits. METHODS: The founders of SPINE20 advocacy group coordinated with G20 Saudi Arabia to conduct the SPINE20 summit in 2020. The summit was intended to promote evidence-based recommendations to use the most reliable information from high-level research. Eight areas of importance to mitigate spine disorders were identified through a voting process of the participating societies. Twelve recommendations were discussed and vetted. RESULTS: The areas of immediate concern were "Aging spine," "Future of spine care," "Spinal cord injuries," "Children and adolescent spine," "Spine-related disability," "Spine Educational Standards," "Patient safety," and "Burden on economy." Twelve recommendations were created and endorsed by 31/33 spine societies and 2 journals globally during a vetted process through the SPINE20.org website and during the virtual inaugural meeting November 10-11, 2020 held from the G20 platform. CONCLUSIONS: This is the first time that international spine societies have joined to support actions to mitigate the burden of spine disorders across the globe. SPINE20 seeks to change awareness and treatment of spine pain by supporting local projects that implement value-based practices with healthcare policies that are culturally sensitive based on scientific evidence.


Asunto(s)
Personas con Discapacidad , Dolor de la Región Lumbar , Enfermedades de la Columna Vertebral , Adolescente , Niño , Carga Global de Enfermedades , Humanos , Columna Vertebral
2.
Eur Spine J ; 27(11): 2847-2853, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30196418

RESUMEN

PURPOSE: This observational study was aimed at quantification of low back pain (LBP) in Parkinsonian patients and its morphological correlation. BACKGROUND: Parkinson's disease (PD) is a common disabling condition in the elderly population. Parkinsonian patients frequently are troubled by LBP. Causes for LBP in PD are muscular imbalances by the movement disorder itself and skeletal degeneration. METHODS: Ninety-seven PD patients and 97 controls were inquired about low back pain through the Oswestry Low Back Pain Disability Questionnaire and visual analogue scales. Fifty-four patients with LBP underwent X-ray of the lumbar spine in two planes and flexion-extension views. Parkinson's disease was characterized by stage, disease duration, motor score, lateralization of symptoms and dosage of medication. RESULTS: LBP occurred significantly more frequent in PD (87.6%) compared to controls (62.6%) with longer duration and higher pain intensity. Pain intensity and disability scores were associated with higher PD stages and higher motor scores. Patients with the hypokinetic PD subtype experienced more pain intensity. X-ray of the lumbar spine revealed lumbar arthrosis in 79.6%, scoliosis in 38.8% and spondylolisthesis in 24.1% of PD patients with LBP. Lateralization of scoliosis and PD symptoms were significantly correlated. Only a small portion of PD patients with LBP received specialized orthopaedic treatment. CONCLUSION: LBP and lumbar degeneration are common in PD. Both are related to movement disorder symptoms. The knowledge about musculoskeletal conditions in Parkinson's disease is important for an interdisciplinary conservative or operative treatment decision of LBP. These slides can be retrieved under Electronic Supplementary Material.


Asunto(s)
Dolor Crónico , Dolor de la Región Lumbar , Procedimientos Ortopédicos , Enfermedad de Parkinson , Enfermedades de la Columna Vertebral , Dolor Crónico/complicaciones , Dolor Crónico/diagnóstico por imagen , Dolor Crónico/epidemiología , Humanos , Dolor de la Región Lumbar/complicaciones , Dolor de la Región Lumbar/diagnóstico por imagen , Dolor de la Región Lumbar/epidemiología , Dolor de la Región Lumbar/cirugía , Vértebras Lumbares/diagnóstico por imagen , Enfermedad de Parkinson/complicaciones , Enfermedad de Parkinson/epidemiología , Prevalencia , Enfermedades de la Columna Vertebral/complicaciones , Enfermedades de la Columna Vertebral/diagnóstico por imagen , Enfermedades de la Columna Vertebral/epidemiología
3.
J Phys Chem B ; 127(11): 2587-2594, 2023 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-36890108

RESUMEN

Synthetic esters are used as lubricants for applications at high temperatures, but their development can be a trial and error process. In this context, molecular dynamics simulations could be used as a tool to investigate the properties of new lubricants, in particular viscosity. We employ nonequilibrium molecular dynamics (NEMD) simulations to predict bulk Newtonian viscosities of a set of mixtures of two esters, di(2-ethylhexyl) sebacate (DEHS) and di(2-ethylhexyl) adipate (DEHA) at 293 and 343 K as well as equilibrium molecular dynamics (EMD) and NEMD at 393 K and compare these to experimental measurements. The simulations predict mixture densities within 5% of the experimental values, and we are able to retrieve between 99% and 75% of the experimental viscosities for all ranges of temperature. Experimental viscosities show a linear trend which we are able to capture using NEMD at low temperature and EMD at high temperature. Our work shows that, using EMD and NEMD simulations, and the workflows we developed, we can obtain reliable estimates of the viscosities of mixtures of industrially relevant ester-based lubricants at different temperatures.

4.
RSC Adv ; 13(48): 33994-34002, 2023 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-38019999

RESUMEN

The behaviour of confined lubricants at the atomic scale as affected by the interactions at the surface-lubricant interface is relevant in a range of technological applications in areas such as the automotive industry. In this paper, by performing fully atomistic molecular dynamics, we investigate the regime where the viscosity starts to deviate from the bulk behaviour, a topic of great practical and scientific relevance. The simulations consist of setting up a shear flow by confining the lubricant between iron oxide surfaces. By using confined Non-Equilibrium Molecular Dynamics (NEMD) simulations at a pressure range of 0.1-1.0 GPa at 100 °C, we demonstrate that the film thickness of the fluid affects the behaviour of viscosity. We find that by increasing the number of lubricant molecules, we approach the viscosity value of the bulk fluid derived from previously published NEMD simulations for the same system. These changes in viscosity occurred at film thicknesses ranging from 10.12 to 55.93 Å. The viscosity deviations at different pressures between the system with the greatest number of lubricant molecules and the bulk simulations varied from -16% to 41%. The choice of the utilized force field for treating the atomic interactions was also investigated.

5.
Eur J Trauma Emerg Surg ; 46(5): 1085-1092, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30269211

RESUMEN

BACKGROUND: Anterior knee pain is the most common complication after intramedullary tibial nailing. Often, the cause is multifactorial and individually different. Violation of the anterior intermeniscal ligament (AIL) during intramedullary tibial nailing might be a possible origin of postsurgical anterior knee pain. Both the importance and function of the AIL remain somewhat ambivalent, and even the figures quoted in the literature for its existence in the population vary drastically. Our aim was to verify the estimated frequency of the AIL in the literature by retrospectively analysing the data of MRI studies conducted at our hospital. In addition, we attempted to assess the potential risk of AIL violation during intramedullary tibial nailing, based on the spatial arrangement. METHODS: Two independent examiners analysed the images generated in 351 MRI studies conducted at our hospital between June 2013 and May 2014. All cases who did not reveal any previous knee-joint injury or osteoarthritis of the knee were allocated to group I. All other cases were included in group II. To estimate the potential risk of AIL injury during the nailing procedure, the distance between the AIL and the theoretical entry point for intramedullary nailing was measured. RESULTS: We identified the AIL on the images of nearly all patients (96.5%) in group I. In group II, the presence of the AIL was confirmed in only 51.4% of cases (p < 0.001). The average distance between the AIL and theoretical entry point for intramedullary tibial nailing was 10.1 mm (range 3.48-18.88 mm). CONCLUSIONS: Because we were able to confirm the presence of the AIL in nearly all patients without a history of knee joint injuries or osteoarthrosis, we presume that the AIL may play a role in knee joint function. Violation of the AIL during intramedullary nailing appears likely due to the close position of the AIL in relation to the entry point for the inserted nail. As a result and due to its rich sensory innervation, a connection between AIL violation during tibial nailing and postoperative onset of anterior knee pain seems likely. To eliminate one risk factor of anterior knee pain development and in view of the unresolved issues of AIL function, violation of the ligament during any operative procedure should be avoided.


Asunto(s)
Clavos Ortopédicos/efectos adversos , Fijación Intramedular de Fracturas/efectos adversos , Articulación de la Rodilla/diagnóstico por imagen , Ligamentos Articulares/diagnóstico por imagen , Ligamentos Articulares/lesiones , Imagen por Resonancia Magnética , Dolor Postoperatorio/etiología , Femenino , Fijación Intramedular de Fracturas/instrumentación , Humanos , Enfermedad Iatrogénica , Articulación de la Rodilla/cirugía , Masculino , Dolor Postoperatorio/diagnóstico por imagen , Estudios Retrospectivos , Fracturas de la Tibia/cirugía
6.
J Neurol Surg A Cent Eur Neurosurg ; 80(1): 15-25, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29852510

RESUMEN

BACKGROUND AND OBJECTIVE: Persistent sacroiliac joint syndrome (PSIJS) may complicate adult spinal deformity surgery (ASDS). This study assesses the relationship between clinical/morphometric parameters and PSIJS following ASDS including pelvic fixation and the therapeutic efficacy of secondary iliosacral fusion (ISF). METHODS: Perioperative health-related quality of life (HRQOL) outcomes (Oswestry Disability Index, Short Form 12-item health survey, version 2 scores) at 6, 12, and 24 months, and radiographic studies were analyzed retrospectively in a cohort of 71 consecutive patients undergoing ASDS. PSIJS was confirmed in nine individuals (12.7%) by placebo-controlled dual sacroiliac joint (SIJ) blocks. The relationships between global and regional spinopelvic morphometry, PSIJS, and HRQOL outcomes were assessed by logistic regression and receiver operating characteristic curve (ROC) analysis. RESULTS: PSIJS, independently causing significantly reduced improvement in HRQOL scores (p < 0.001) 6 months postoperatively, warranted secondary ISF in nine patients (12.7%) within 12 months of index surgery, without evidence of progressive SIJ arthrosis, pseudarthrosis, or hardware issues. Eight of nine patients undergoing secondary ISF reported≥ 70% pain reduction at 24 months. Logistic regression/ROC analysis revealed a close association between PSIJS and nonharmonious postoperative L4-S1 fractional lordosis (p < 0.0001), pelvic incidence angle > 53 degrees, hip arthrosis, and preexistent advanced SIJ arthrosis (p < 0.01). CONCLUSION: PSIJS may negatively impact the clinical outcome of ASDS. Recurrent preoperative SIJ syndrome requiring interventional treatment, preexisting hip and SIJ arthrosis, insufficient restoration of L4-S1 fractional lordosis, and high pelvic incidence predispose to PSIJS. PSIJS may potentially be avoided by restoring physiologic lumbosacral geometry and S2 sacral alar-iliac screw fixation during index surgery. Secondary ISF appears to be effective in reducing pain and physical impairment due to PSIJS.


Asunto(s)
Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/etiología , Articulación Sacroiliaca , Curvaturas de la Columna Vertebral/cirugía , Fusión Vertebral/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Tornillos Óseos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Estudios Retrospectivos , Curvaturas de la Columna Vertebral/complicaciones , Curvaturas de la Columna Vertebral/diagnóstico por imagen , Fusión Vertebral/efectos adversos , Síndrome , Resultado del Tratamiento
7.
Materials (Basel) ; 13(1)2019 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-31905807

RESUMEN

The current work presents the results of an investigation focused on the influence of process parameters on the melt-track stability and its consequence to the sample density printed out of NdFeB powder. Commercially available powder of Nd7.5Pr0.7Fe75.4Co2.5B8.8Zr2.6Ti2.5 alloy was investigated at the angle of application in selective laser melting of permanent magnets. Using single track printing the stability of the melt pool was investigated under changing process parameters. The influence of changing laser power, scanning speed, and powder layer thickness on density, porosity structure, microstructure, phase composition, and magnetic properties were investigated. The results showed that energy density coupled with powder layer thickness plays a crucial role in melt-track stability. It was possible to manufacture magnets of both high relative density and high magnetic properties. Magnetization tests showed a significant correlation between the shape of the demagnetization curve and the layer height. While small layer heights are beneficial for sufficient magnetic properties, the remaining main parameters tend to affect the magnetic properties less. A quasi-linear correlation between the layer height and the magnetic properties remanence (Jr), coercivity (HcJ) and maximum energy product ((BH)max) was found.

8.
J Neurosurg Spine ; 28(4): 406-415, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29372860

RESUMEN

OBJECTIVE Surgical decompression is extremely effective in relieving pain and symptoms due to lumbar spinal stenosis (LSS). Decompression with interlaminar stabilization (D+ILS) is as effective as decompression with posterolateral fusion for stenosis, as shown in a major US FDA pivotal trial. This study reports a multicenter, randomized controlled trial in which D+ILS was compared with decompression alone (DA) for treatment of moderate to severe LSS. METHODS Under approved institutional ethics review, 230 patients (1:1 ratio) randomized to either DA or D+ILS (coflex, Paradigm Spine) were treated at 7 sites in Germany. Patients had moderate to severe LSS at 1 or 2 adjacent segments from L-3 to L-5. Outcomes were evaluated up to 2 years postoperatively, including Oswestry Disability Index (ODI) scores, the presence of secondary surgery or lumbar injections, neurological status, and the presence of device- or procedure-related severe adverse events. The composite clinical success (CCS) was defined as combining all 4 of these outcomes, a success definition validated in a US FDA pivotal trial. Additional secondary end points included visual analog scale (VAS) scores, Zürich Claudication Questionnaire (ZCQ) scores, narcotic usage, walking tolerance, and radiographs. RESULTS The overall follow-up rate was 91% at 2 years. There were no significant differences in patient-reported outcomes at 24 months (p > 0.05). The CCS was superior for the D+ILS arm (p = 0.017). The risk of secondary intervention was 1.75 times higher among patients in the DA group than among those in the D+ILS group (p = 0.055). The DA arm had 228% more lumbar injections (4.5% for D+ILS vs 14.8% for DA; p = 0.0065) than the D+ILS one. Patients who underwent DA had a numerically higher rate of narcotic use at every time point postsurgically (16.7% for D+ILS vs 23% for DA at 24 months). Walking Distance Test results were statistically significantly different from baseline; the D+ILS group had > 2 times the improvement of the DA. The patients who underwent D+ILS had > 5 times the improvement from baseline compared with only 2 times the improvement from baseline for the DA group. Foraminal height and disc height were largely maintained in patients who underwent D+ILS, whereas patients treated with DA showed a significant decrease at 24 months postoperatively (p < 0.001). CONCLUSIONS This study showed no significant difference in the individual patient-reported outcomes (e.g., ODI, VAS, ZCQ) between the treatments when viewed in isolation. The CCS (survivorship, ODI success, absence of neurological deterioration or device- or procedure-related severe adverse events) is statistically superior for ILS. Microsurgical D+ILS increases walking distance, decreases compensatory pain management, and maintains radiographic foraminal height, extending the durability and sustainability of a decompression procedure. Clinical trial registration no.: NCT01316211 (clinicaltrials.gov).


Asunto(s)
Descompresión Quirúrgica/instrumentación , Vértebras Lumbares/cirugía , Estenosis Espinal/cirugía , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Neuroquirúrgicos/instrumentación , Procedimientos Neuroquirúrgicos/métodos , Manejo del Dolor , Estudios Prospectivos , Fusión Vertebral/métodos , Resultado del Tratamiento
9.
Eur J Trauma Emerg Surg ; 44(6): 927-938, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29159663

RESUMEN

BACKGROUND: During intramedullary nailing of tibial fractures, the insertion angle of the nail is of great importance. When the nail impacts the posterior cortex due to a large insertion angle with a dorsal target course, higher insertion forces are needed, and the danger of iatrogenic fractures increases. Accordingly, the insertion direction should be as parallel as possible to the longitudinal axis of the tibia. We aimed to confirm the hypothesis that intramedullary nailing of tibial fractures can be performed with smaller insertion angles via a suprapatellar approach rather than infrapatellar approach. METHODS: In 19 human bodies of donors with intact tibiae, we performed intramedullary nailing by both a suprapatellar and an infrapatellar approach. The correct entry point was determined by fluoroscopy. Subsequently, the medullary canal was reamed up to a diameter of 10 mm, and a 9 mm polytetrafluorethylen tube was inserted instead of a tibia nail. The angle between the proximal aspect of the tube and the longitudinal axis of the tibia was measured using a computer-assisted surgery system. RESULTS: The angle between the proximal aspect of the inserted tube, simulating the tibial nail, and the longitudinal tibial axis was significantly larger when using the infrapatellar approach. CONCLUSIONS: We achieved an insertion angle significantly more parallel to the longitudinal axis when using a suprapatellar approach for intramedullary nailing of tibial fractures. Thereby, both the risk of iatrogenic fracture of the posterior cortex and apex anterior angulation of the short proximal fragment can be reduced during intramedullary nailing of tibial fractures.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Rótula , Fracturas de la Tibia/cirugía , Anciano , Anciano de 80 o más Años , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fracturas de la Tibia/diagnóstico por imagen
10.
EuroIntervention ; 13(10): 1234-1241, 2017 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-28671551

RESUMEN

AIMS: Device sizing for LAA closure using transoesophageal echocardiography (TEE) can be challenging due to complex LAA anatomy. We investigated whether the use of 3D-printed left atrial appendage (LAA) models based on preprocedural computed tomography (CT) permits accurate device sizing. METHODS AND RESULTS: Twenty-two (22) patients (73±8 years, 55% male) with atrial fibrillation requiring anticoagulation at high bleeding risk underwent LAA closure (WATCHMAN device). Preprocedurally, LAA was sized by TEE and third-generation dual-source CT. Based on CT, 3D printing models of LAA anatomy were created for simulation of device implantation. Device compression was assessed in a CT scan of the 3D model with the implanted device. Implantation was successful in all patients. Mean LAA ostium diameter based on TEE was 22±4 mm and based on CT 25±3 mm (p=0.014). Predicted device size based on simulated implantation in the 3D model was equal to the device finally implanted in 21/22 patients (95%). TEE would have undersized the device in 10/22 patients (45%). Device compression determined in the 3D-CT model corresponded closely with compression upon implantation (16±3% vs. 18±5%, r=0.622, p=0.003). CONCLUSIONS: Patient-specific CT-based 3D printing models may assist device selection and prediction of device compression in the context of interventional LAA closure.


Asunto(s)
Apéndice Atrial/cirugía , Cateterismo Cardíaco , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Impresión Tridimensional , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/instrumentación , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Implantación de Prótesis , Tomografía Computarizada por Rayos X
11.
Neurosurgery ; 69(6): 1307-16, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21734616

RESUMEN

BACKGROUND: Image-guided spinal instrumentation may reduce complications in spinal instrumentation. OBJECTIVE: To assess accuracy, time efficiency, and staff radiation exposure during thoracolumbar screw instrumentation guided by intraoperative computed tomography (iCT)-based neuronavigation (iCT-N). METHODS: In 55 patients treated for idiopathic and degenerative deformities, 826 screws were inserted in the thoracic (T2-T12; n = 243) and lumbosacral (L1-S1; n = 545) spine, as well as ilium (n = 38) guided by iCT-N. Up to 17 segments were instrumented following a single automated registration sequence with the dynamic reference arc (DRA) uniformly attached to L5. Accuracy of iCT-N was assessed by calculating angular deviations between individual navigated tool trajectories and final implant positions. Final screw positions were also graded according to established classification systems. Clinical and radiological outcome was assessed at 12 to 14 months. RESULTS: Additional intraoperative fluoroscopy was unnecessary, eliminating staff radiation exposure. Unisegmental K-wire insertion required 4.6 ± 2.9 minutes. Of the thoracic pedicle screws 98.4% were assigned grades I to III according to the Heary classification, with 1.6% grade IV placement. In the lumbar spine, 94.4% of screws were completely contained (Gertzbein classification grade 0), 4.6% displayed minor pedicle breaches <2 mm (grade 1), and 1% of lumbar screws deviated by >2 to <4 mm (grade 2). The accuracy of iCT-N progressively deteriorates with increasing distance from the DRA, but allows safe instrumentation of up to 12 segments. CONCLUSION: iCT-N using automated referencing allows for safe, highly accurate multilevel instrumentation of the entire thoracolumbosacral spine and ilium, rendering additional intraoperative imaging dispensable. In addition, automated registration is time-efficient and significantly reduces the need for re-registration in multilevel surgery.


Asunto(s)
Tornillos Óseos , Vértebras Lumbares/cirugía , Neuronavegación , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Neuroquirúrgicos , Estudios Retrospectivos , Fusión Vertebral , Adulto Joven
12.
Neurosurgery ; 69(4): 782-95; discussion 795, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21552171

RESUMEN

BACKGROUND: Image-guided spinal instrumentation reduces the incidence of implant misplacement. OBJECTIVE: To assess the accuracy of intraoperative computed tomography (iCT)-based neuronavigation (iCT-N). METHODS: In 35 patients (age range, 18-87 years), a total of 248 pedicle screws were placed in the cervical (C1-C7) and upper and midthoracic (T1-T8) spine. An automated iCT registration sequence was used for multisegmental instrumentation, with the reference frame fixed to either a Mayfield head clamp and/or the most distal spinous process within the instrumentation. Pediculation was performed with navigated drill guides or Jamshidi cannulas. The angular deviation between navigated tool trajectory and final implant positions (evaluated on postinstrumentation iCT or postoperative CT scans) was calculated to assess the accuracy of iCT-N. Final screw positions were also graded according to established classification systems. Mean follow-up was 16.7 months. RESULTS: Clinically significant screw misplacement or iCT-N failure mandating conversion to conventional technique did not occur. A total of 71.4% of patients self-rated their outcome as excellent or good at 12 months; 99.3% of cervical screws were compliant with Neo classification grades 0 and 1 (grade 2, 0.7%), and neurovascular injury did not occur. In addition, 97.8% of thoracic pedicle screws were assigned grades I to III of the Heary classification, with 2.2% grade IV placement. Accuracy of iCT-N progressively deteriorated with increasing distance from the spinal reference clamp but allowed safe instrumentation of up to 10 segments. CONCLUSION: Image-guided spinal instrumentation using iCT-N with automated referencing allows safe, highly accurate multilevel instrumentation of the cervical and upper and midthoracic spine. In addition, iCT-N significantly reduces the need for reregistration in multilevel surgery.


Asunto(s)
Neuronavegación/métodos , Fusión Vertebral/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Tornillos Óseos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Fusión Vertebral/instrumentación , Tomografía Computarizada por Rayos X , Adulto Joven
13.
Spine (Phila Pa 1976) ; 29(22): 2516-20, 2004 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-15543064

RESUMEN

STUDY DESIGN: Retrospective study on the incidence of reoperation in patients previously treated by instrumented posterior lumbar interbody fusion. OBJECTIVES: To answer the following questions: Reoperation rate after PLIF? And is there any influence of the length of fusion on the reoperation rate? SUMMARY OF BACKGROUND DATA: The use of different techniques demonstrates that there is currently no ideal procedure for lumbar fusion. The instrumented posterior lumbar interbody fusion (PLIF) shows a comparable success rate to the so-called 360 degrees fusion techniques (combined dorsoventral spondylodesis) without the need of an anterior approach. METHODS: We reviewed 1680 patients who underwent a PLIF at our institution between January 1995 and December 2000. A total of 3053 levels were fused. The reoperation rate was analyzed. The mean follow-up was 5 years. RESULTS: There were 221 (13.2%) reoperations in 206 patients (12.2%). Of 1680 PLIFs, 312 were multisegmental (>2 segments). Within this group, 45 (14.4%) revisions were done. We found that the most important difference between the multisegmental PLIFs and the mono- or bisegmental PLIFs is the rate of adjacent segment decompensation (5.1% vs. 2.3%), and this was statistically significant. The reoperation rate between those two groups was only slightly different with 12.9% for mono- or bisegmental and 14.4% for multisegmental PLIFs. CONCLUSIONS: The fusion length does not show a significant difference in the reoperation rate as such. Nevertheless, we registered a significantly higher incidence for decompensation of adjacent segments after multisegmental PLIFs.


Asunto(s)
Vértebras Lumbares/cirugía , Reoperación , Enfermedades de la Columna Vertebral/epidemiología , Enfermedades de la Columna Vertebral/cirugía , Fusión Vertebral , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Radiografía , Estudios Retrospectivos , Enfermedades de la Columna Vertebral/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA