Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Thorac Cardiovasc Surg ; 65(4): 322-324, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27494750

RESUMEN

The small saphenous vein (SSV) has proved to be a valid graft option for coronary artery bypass grafting (CABG), if other grafts are absent or unsuitable. Beside the described open technique we herein present our approach to endoscopic harvesting in supine position in seven patients. Harvesting was successful in six patients. Mean skin-to-skin time was 29.8 minutes. There were no infections or neurological deficits and the intraoperatively measured graft flow was excellent according to mean flow and low pulsatility index. Therefore, endoscopic harvesting of the SSV extends surgical opportunities not only in CABG, but also in surgery of peripheral artery disease.


Asunto(s)
Puente de Arteria Coronaria/métodos , Endoscopía , Posicionamiento del Paciente , Vena Safena/trasplante , Posición Supina , Recolección de Tejidos y Órganos/métodos , Humanos , Tempo Operativo , Factores de Tiempo , Resultado del Tratamiento
2.
Thorac Cardiovasc Surg ; 65(3): 212-217, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27517166

RESUMEN

Background The incidence of degenerative aortic valve diseases has increased along with the life expectancy of our population. Although conventional aortic valve replacement (AVR) is the gold standard for symptomatic aortic stenosis, transcatheter procedures have proven to be a valid therapeutic option in high-risk patients. The aim of this study was to compare these procedures in a high-risk cohort. Methods We retrospectively analyzed all symptomatic (dyspnea or angina) high-risk patients (logistic EuroSCORE ≥ 15%) fulfilling the transcatheter aortic valve implantation (TAVI) indications. Most of the AVR patients (n = 180) were operated on before the implementation of TAVI. All TAVI procedures (n = 127) were performed transapically (TA). After matching for age, logistic EuroSCORE, and left ventricular ejection fraction, 82 pairs of patients were evaluated. Results When comparing AVR with TA-TAVI, there was no difference between groups in survival after 1 year (Kaplan-Meier analysis, 81.1% [95% CI: 72.5-89.7%] vs. 75.8% [95% CI: 66.2-75.9%], Log tank p = 0.660) and the complication rates (n for AVR vs. TA-TAVI: stroke, 2 vs. 0, p = 0.580; acute renal insufficiency, 8 vs. 12, p = 0.340; atrial fibrillation, 24 vs. 26, p = 0.813; pacemaker implantation, 4 vs. 4, p > 0.999). In addition, quality of life did not differ between groups. Patients in the TA-TAVI group had lower mean valvular gradients postoperatively compared with the AVR group (14.6 ± 6.6 vs. 10.2 ± 4.9 mm Hg, p < 0.001). Conclusion For high-risk patients, the TAVI procedure is comparable with conventional AVR, but is not advantageous. These results do not support the expansion of TAVI to low- or intermediate-risk patients.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Alemania , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Estimación de Kaplan-Meier , Masculino , Selección de Paciente , Complicaciones Posoperatorias/etiología , Calidad de Vida , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Función Ventricular Izquierda
3.
Thorac Cardiovasc Surg ; 62(1): 42-6, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23881507

RESUMEN

BACKGROUND: Minimally invasive extracorporeal circulation (MECC) technology was applied predominantly in coronary surgery. Data regarding the application of MECC in minimally invasive valve surgery are missing largely. PATIENTS AND METHODS: Patients undergoing isolated minimally invasive mitral or aortic valve procedures were allocated either to conventional extracorporeal circulation (CECC) group (n = 63) or MECC group (n = 105), and their prospectively generated data were analyzed. RESULTS: Demographic data were comparable between the groups regarding age (CECC vs. MECC: 71.0 ± 7.5 vs. 66.2 ± 10.1 years, p = 0.091) and logistic EuroSCORE I (6.2 ± 2.5 vs. 5.4 ± 3.0, p = 0.707). Hospital mortality was one patient in each group (1.6 vs. 1.0%, p = 0.688). The levels of leukocytes were lower in the MECC group (11.6 ± 3.2 vs. 9.4 ± 4.3 109/L, p = 0.040). Levels of platelets (137.2 ± 45.5 vs. 152.4 ± 50.3 109/L, p = 0.015) and hemoglobin (103.3 ± 11.3 vs. 107.3 ± 14.7 g/L, p = 0.017) were higher in the MECC group. Renal function was better preserved (creatinine: 1.1 ± 0.4 vs. 0.9 ± 0.2 mg/dL, p = 0.019). We were able to validate shorter time of postoperative ventilation (9.5 ± 15.1 vs. 6.3 ± 3.4 h, p = 0.054) as well as significantly shorter intensive care unit (ICU) stay (1.8 ± 1.3 vs. 1.2 ± 1.0 d, p = 0.005) for MECC patients. The course of C-reactive protein did not differ between the groups. CONCLUSION: We were able to prove the feasibility of MECC even in minimally invasive performed mitral and aortic valve procedures. In addition, the use of MECC provides decreased platelet consumption and less hemodilution. The use of MECC in these selected patients lead to a shorter ventilation time and ICU stay.


Asunto(s)
Válvula Aórtica/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Circulación Extracorporea/métodos , Enfermedades de las Válvulas Cardíacas/cirugía , Válvula Mitral/cirugía , Anciano , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Circulación Extracorporea/efectos adversos , Circulación Extracorporea/mortalidad , Estudios de Factibilidad , Femenino , Enfermedades de las Válvulas Cardíacas/mortalidad , Hemodilución , Mortalidad Hospitalaria , Humanos , Unidades de Cuidados Intensivos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Respiración Artificial , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
J Heart Lung Transplant ; 26(2): 194-5, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17258155

RESUMEN

Organ transplantation is limited by a worldwide organ scarcity. Heart and lung transplantation are particularly affected by this limitation. Consequently, there is increasing interest in transplantation of organs from marginal donors. We report a patient who underwent successful bilateral lung transplantation from a donor with fume poisoning and subsequent resuscitation.


Asunto(s)
Trasplante de Pulmón/métodos , Lesión por Inhalación de Humo , Donantes de Tejidos , Adulto , Humanos , Masculino , Obtención de Tejidos y Órganos/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA