Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
2.
J Synchrotron Radiat ; 29(Pt 6): 1480-1494, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36345756

RESUMEN

The highly automated macromolecular crystallography beamline AMX/17-ID-1 is an undulator-based high-intensity (>5 × 1012 photons s-1), micro-focus (7 µm × 5 µm), low-divergence (1 mrad × 0.35 mrad) energy-tunable (5-18 keV) beamline at the NSLS-II, Brookhaven National Laboratory, Upton, NY, USA. It is one of the three life science beamlines constructed by the NIH under the ABBIX project and it shares sector 17-ID with the FMX beamline, the frontier micro-focus macromolecular crystallography beamline. AMX saw first light in March 2016 and started general user operation in February 2017. At AMX, emphasis has been placed on high throughput, high capacity, and automation to enable data collection from the most challenging projects using an intense micro-focus beam. Here, the current state and capabilities of the beamline are reported, and the different macromolecular crystallography experiments that are routinely performed at AMX/17-ID-1 as well as some plans for the near future are presented.


Asunto(s)
Sincrotrones , Cristalografía por Rayos X , Sustancias Macromoleculares/química
3.
J Synchrotron Radiat ; 28(Pt 5): 1649-1661, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34475312

RESUMEN

Here we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.


Asunto(s)
Cristalografía por Rayos X/métodos , Sustancias Macromoleculares/química , Robótica/métodos , Diseño de Equipo , Dispersión del Ángulo Pequeño , Programas Informáticos , Sincrotrones , Rayos X
4.
J Synchrotron Radiat ; 28(Pt 2): 650-665, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33650577

RESUMEN

Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425, 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493, 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015, 1741, 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5-30 keV photon energy range and delivers a flux of 4.0 × 1012 photons s-1 at 1 Šinto a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 1012 photons s-1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods - serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25, 1362-1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ, 5, 238-246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5, 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.


Asunto(s)
Sincrotrones , Cristalografía , Cristalografía por Rayos X , Recolección de Datos , Sustancias Macromoleculares , Viscosidad
5.
Molecules ; 24(3)2019 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-30704096

RESUMEN

Advances in synchrotron technology are changing the landscape of macromolecular crystallography. The two recently opened beamlines at NSLS-II-AMX and FMX-deliver high-flux microfocus beams that open new possibilities for crystallographic data collection. They are equipped with state-of-the-art experimental stations and automation to allow data collection on previously intractable crystals. Optimized data collection strategies allow users to tailor crystal positioning to optimally distribute the X-ray dose over its volume. Vector data collection allows the user to define a linear trajectory along a well diffracting volume of the crystal and perform rotational data collection while moving along the vector. This is particularly well suited to long, thin crystals. We describe vector data collection of three proteins-Akt1, PI3Kα, and CDP-Chase-to demonstrate its application and utility. For smaller crystals, we describe two methods for multicrystal data collection in a single loop, either manually selecting multiple centers (using H108A-PHM as an example), or "raster-collect", a more automated approach for a larger number of crystals (using CDP-Chase as an example).


Asunto(s)
Cristalografía por Rayos X , Modelos Moleculares , Proteínas/química , Cristalografía por Rayos X/métodos , Fosfatidilinositol 3-Quinasas/química , Conformación Proteica , Pirofosfatasas/química
6.
J Synchrotron Radiat ; 25(Pt 5): 1362-1370, 2018 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-30179174

RESUMEN

The Frontier Microfocus Macromolecular Crystallography (FMX) beamline at the National Synchrotron Light Source II with its 1 µm beam size and photon flux of 3 × 1012 photons s-1 at a photon energy of 12.66 keV has reached unprecedented dose rates for a structural biology beamline. The high dose rate presents a great advantage for serial microcrystallography in cutting measurement time from hours to minutes. To provide the instrumentation basis for such measurements at the full flux of the FMX beamline, a high-speed, high-precision goniometer based on a unique XYZ piezo positioner has been designed and constructed. The piezo-based goniometer is able to achieve sub-100 nm raster-scanning precision at over 10 grid-linepairs s-1 frequency for fly scans of a 200 µm-wide raster. The performance of the scanner in both laboratory and serial crystallography measurements up to the maximum frame rate of 750 Hz of the Eiger 16M's 4M region-of-interest mode has been verified in this work. This unprecedented experimental speed significantly reduces serial-crystallography data collection time at synchrotrons, allowing utilization of the full brightness of the emerging synchrotron radiation facilities.

7.
Acta Crystallogr D Biol Crystallogr ; 71(Pt 1): 27-35, 2015 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-25615857

RESUMEN

Combining macromolecular crystallography with in crystallo micro-spectrophotometry yields valuable complementary information on the sample, including the redox states of metal cofactors, the identification of bound ligands and the onset and strength of undesired photochemistry, also known as radiation damage. However, the analysis and processing of the resulting data differs significantly from the approaches used for solution spectrophotometric data. The varying size and shape of the sample, together with the suboptimal sample environment, the lack of proper reference signals and the general influence of the X-ray beam on the sample have to be considered and carefully corrected for. In the present article, how to characterize and treat these sample-dependent artefacts in a reproducible manner is discussed and the SLS-APE in situ, in crystallo optical spectroscopy data-analysis toolbox is demonstrated.


Asunto(s)
Cristalografía/métodos , Espectrofotometría Ultravioleta/métodos , Espectrometría Raman/métodos , Automatización , Fluorescencia
8.
J Synchrotron Radiat ; 22(4): 895-900, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26134792

RESUMEN

The Parallel Robotics Inspired Goniometer (PRIGo) is a novel compact and high-precision goniometer providing an alternative to (mini-)kappa, traditional three-circle goniometers and Eulerian cradles used for sample reorientation in macromolecular crystallography. Based on a combination of serial and parallel kinematics, PRIGo emulates an arc. It is mounted on an air-bearing stage for rotation around ω and consists of four linear positioners working synchronously to achieve x, y, z translations and χ rotation (0-90°), followed by a ϕ stage (0-360°) for rotation around the sample holder axis. Owing to the use of piezo linear positioners and active correction, PRIGo features spheres of confusion of <1 µm, <7 µm and <10 µm for ω, χ and ϕ, respectively, and is therefore very well suited for micro-crystallography. PRIGo enables optimal strategies for both native and experimental phasing crystallographic data collection. Herein, PRIGo hardware and software, its calibration, as well as applications in macromolecular crystallography are described.

9.
Acta Crystallogr D Biol Crystallogr ; 70(Pt 5): 1289-96, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24816098

RESUMEN

It is crucial to assign the correct redox and ligand states to crystal structures of proteins with an active redox centre to gain valid functional information and prevent the misinterpretation of structures. Single-crystal spectroscopies, particularly when applied in situ at macromolecular crystallography beamlines, allow spectroscopic investigations of redox and ligand states and the identification of reaction intermediates in protein crystals during the collection of structural data. Single-crystal resonance Raman spectroscopy was carried out in combination with macromolecular crystallography on Swiss Light Source beamline X10SA using cytochrome c' from Alcaligenes xylosoxidans. This allowed the fingerprinting and validation of different redox and ligand states, identification of vibrational modes and identification of intermediates together with monitoring of radiation-induced changes. This combined approach provides a powerful tool to obtain complementary data and correctly assign the true oxidation and ligand state(s) in redox-protein crystals.


Asunto(s)
Cristalografía por Rayos X/métodos , Citocromos c/química , Hemoproteínas/química , Espectrometría Raman , Alcaligenes/química , Citocromos c/metabolismo , Hemoproteínas/metabolismo , Ligandos , Modelos Moleculares , Oxidación-Reducción , Conformación Proteica
10.
J Am Chem Soc ; 136(1): 137-46, 2014 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-24328211

RESUMEN

Cellular retinaldehyde-binding protein (CRALBP) chaperones 11-cis-retinal to convert opsin receptor molecules into photosensitive retinoid pigments of the eye. We report a thermal secondary isomerase activity of CRALBP when bound to 9-cis-retinal. UV/vis and (1)H NMR spectroscopy were used to characterize the product as 9,13-dicis-retinal. The X-ray structure of the CRALBP mutant R234W:9-cis-retinal complex at 1.9 Å resolution revealed a niche in the binding pocket for 9-cis-aldehyde different from that reported for 11-cis-retinal. Combined computational, kinetic, and structural data lead us to propose an isomerization mechanism catalyzed by a network of buried waters. Our findings highlight a specific role of water molecules in both CRALBP-assisted specificity toward 9-cis-retinal and its thermal isomerase activity yielding 9,13-dicis-retinal. Kinetic data from two point mutants of CRALBP support an essential role of Glu202 as the initial proton donor in this isomerization reaction.


Asunto(s)
Proteínas Portadoras/metabolismo , Isomerasas/química , Isomerasas/metabolismo , Retinaldehído/química , Proteínas Portadoras/química , Cromatografía Líquida de Alta Presión , Cristalografía por Rayos X , Diterpenos , Humanos , Cinética , Espectroscopía de Resonancia Magnética , Modelos Moleculares , Teoría Cuántica , Especificidad por Sustrato
11.
J Synchrotron Radiat ; 21(Pt 2): 340-51, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24562555

RESUMEN

A new diffractometer for microcrystallography has been developed for the three macromolecular crystallography beamlines of the Swiss Light Source. Building upon and critically extending previous developments realised for the high-resolution endstations of the two undulator beamlines X06SA and X10SA, as well as the super-bend dipole beamline X06DA, the new diffractometer was designed to the following core design goals. (i) Redesign of the goniometer to a sub-micrometer peak-to-peak cylinder of confusion for the horizontal single axis. Crystal sizes down to at least 5 µm and advanced sample-rastering and scanning modes are supported. In addition, it can accommodate the new multi-axis goniometer PRIGo (Parallel Robotics Inspired Goniometer). (ii) A rapid-change beam-shaping element system with aperture sizes down to a minimum of 10 µm for microcrystallography measurements. (iii) Integration of the on-axis microspectrophotometer MS3 for microscopic sample imaging with 1 µm image resolution. Its multi-mode optical spectroscopy module is always online and supports in situ UV/Vis absorption, fluorescence and Raman spectroscopy. (iv) High stability of the sample environment by a mineral cast support construction and by close containment of the cryo-stream. Further features are the support for in situ crystallization plate screening and a minimal achievable detector distance of 120 mm for the Pilatus 6M, 2M and the macromolecular crystallography group's planned future area detector Eiger 16M.

12.
Acta Crystallogr D Biol Crystallogr ; 69(Pt 1): 137-40, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23275172

RESUMEN

Despite their high physiological relevance, haemoglobin crystal structures with NO bound to haem constitute less than 1% of the total ligated haemoglobins (Hbs) deposited in the Protein Data Bank. The major difficulty in obtaining NO-ligated Hbs is most likely to be related to the oxidative denitrosylation caused by the high reactivity of the nitrosylated species with O(2). Here, using Raman-assisted X-ray crystallography, it is shown that under X-ray exposure (at four different radiation doses) crystals of nitrosylated haemoglobin from Trematomus bernacchii undergo a transition, mainly in the ß chains, that generates a pentacoordinate species owing to photodissociation of the Fe-NO bond. These data provide a physical explanation for the low number of nitrosylated Hb structures available in the literature.


Asunto(s)
Hemoglobinas/química , Hemoglobinas/efectos de la radiación , Óxido Nítrico/química , Óxido Nítrico/efectos de la radiación , Procesos Fotoquímicos , Espectrometría Raman , Animales , Cristalografía por Rayos X/métodos , Peces , Hemoglobinas/metabolismo , Microespectrofotometría/métodos , Óxido Nítrico/metabolismo , Procesos Fotoquímicos/efectos de la radiación , Espectrometría Raman/métodos
13.
J Synchrotron Radiat ; 20(Pt 5): 765-76, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23955041

RESUMEN

The combination of X-ray diffraction experiments with optical methods such as Raman, UV/Vis absorption and fluorescence spectroscopy greatly enhances and complements the specificity of the obtained information. The upgraded version of the in situ on-axis micro-spectrophotometer, MS2, at the macromolecular crystallography beamline X10SA of the Swiss Light Source is presented. The instrument newly supports Raman and resonance Raman spectroscopy, in addition to the previously available UV/Vis absorption and fluorescence modes. With the recent upgrades of the spectral bandwidth, instrument stability, detection efficiency and control software, the application range of the instrument and its ease of operation were greatly improved. Its on-axis geometry with collinear X-ray and optical axes to ensure optimal control of the overlap of sample volumes probed by each technique is still unique amongst comparable facilities worldwide and the instrument has now been in general user operation for over two years.


Asunto(s)
Cristalografía por Rayos X , Espectrometría Raman/instrumentación , Diseño Asistido por Computadora , Cristalografía por Rayos X/instrumentación , Cristalografía por Rayos X/métodos , Diseño de Equipo , Sustancias Macromoleculares , Reproducibilidad de los Resultados , Programas Informáticos , Espectrometría de Fluorescencia/instrumentación , Espectrometría de Fluorescencia/métodos , Espectrofotometría Ultravioleta/instrumentación , Espectrofotometría Ultravioleta/métodos , Espectrometría Raman/métodos
14.
Acta Crystallogr D Biol Crystallogr ; 68(Pt 3): 321-3, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22349234

RESUMEN

A new chip-based crystal-mounting approach for rapid room-temperature data collection from numerous crystals is described. This work was motivated by the recent development of X-ray free-electron lasers. These novel sources deliver very intense femtosecond X-ray pulses that promise to yield high-resolution diffraction data of nanocrystals before their destruction by radiation damage. Thus, the concept of `diffraction before destruction' requires rapid replenishment of the sample for each exposure. The chip promotes the self-assembly of an array of protein crystals on a surface. Rough features on the surface cause the crystals to adopt random orientations, allowing efficient sampling of reciprocal space.


Asunto(s)
Cristalografía por Rayos X/instrumentación , Cristalografía por Rayos X/métodos , Rayos Láser , Nanopartículas/química , Proteínas/química
15.
J Synchrotron Radiat ; 19(Pt 3): 442-9, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22514183

RESUMEN

Three macromolecular crystallography (MX) beamlines at the Helmholtz-Zentrum Berlin (HZB) are available for the regional, national and international structural biology user community. The state-of-the-art synchrotron beamlines for MX BL14.1, BL14.2 and BL14.3 are located within the low-ß section of the BESSY II electron storage ring. All beamlines are fed from a superconducting 7 T wavelength-shifter insertion device. BL14.1 and BL14.2 are energy tunable in the range 5-16 keV, while BL14.3 is a fixed-energy side station operated at 13.8 keV. All three beamlines are equipped with CCD detectors. BL14.1 and BL14.2 are in regular user operation providing about 200 beam days per year and about 600 user shifts to approximately 50 research groups across Europe. BL14.3 has initially been used as a test facility and was brought into regular user mode operation during the year 2010. BL14.1 has recently been upgraded with a microdiffractometer including a mini-κ goniometer and an automated sample changer. Additional user facilities include office space adjacent to the beamlines, a sample preparation laboratory, a biology laboratory (safety level 1) and high-end computing resources. In this article the instrumentation of the beamlines is described, and a summary of the experimental possibilities of the beamlines and the provided ancillary equipment for the user community is given.


Asunto(s)
Cristalografía por Rayos X , Genómica/métodos , Sustancias Macromoleculares/química , Sincrotrones/instrumentación , Animales , Automatización de Laboratorios , Hidrolasas/química , Ratones , Opsinas/química , Orosomucoide/química
16.
IUCrJ ; 9(Pt 6): 768-777, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36381147

RESUMEN

De novo structure determination from single-wavelength anomalous diffraction using native sulfur or phospho-rus in biomolecules (native-SAD) is an appealing method to mitigate the labor-intensive production of heavy-atom derivatives and seleno-methio-nyl substitutions. The native-SAD method is particularly attractive for membrane proteins, which are difficult to produce and often recalcitrant to grow into decent-sized crystals. Native-SAD uses lower-energy X-rays to enhance anomalous signals from sulfur or phospho-rus. However, at lower energies, the scattering and absorption of air contribute to the background noise, reduce the signals and are thus adverse to native-SAD phasing. We have previously demonstrated native-SAD phasing at an energy of 5 keV in air at the NSLS-II FMX beamline. Here, the use of a helium path developed to reduce both the noise from background scattering and the air absorption of the diffracted X-ray beam are described. The helium path was used for collection of anomalous diffraction data at 5 keV for two proteins: thaumatin and the membrane protein TehA. Although anomalous signals from each individual crystal are very weak, robust anomalous signals are obtained from data assembled from micrometre-sized crystals. The thaumatin structure was determined from 15 microcrystals and the TehA structure from 18 microcrystals. These results demonstrate the usefulness of a helium environment in support of native-SAD phasing at 5 keV.

17.
IUCrJ ; 9(Pt 5): 682-694, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-36071812

RESUMEN

The COVID-19 pandemic, instigated by the SARS-CoV-2 coronavirus, continues to plague the globe. The SARS-CoV-2 main protease, or Mpro, is a promising target for the development of novel antiviral therapeutics. Previous X-ray crystal structures of Mpro were obtained at cryogenic tem-per-ature or room tem-per-ature only. Here we report a series of high-resolution crystal structures of unliganded Mpro across multiple tem-per-atures from cryogenic to physiological, and another at high humidity. We inter-rogate these data sets with parsimonious multiconformer models, multi-copy ensemble models, and isomorphous difference density maps. Our analysis reveals a perturbation-dependent conformational landscape for Mpro, including a mobile zinc ion inter-leaved between the catalytic dyad, mercurial conformational heterogeneity at various sites including a key substrate-binding loop, and a far-reaching intra-molecular network bridging the active site and dimer inter-face. Our results may inspire new strategies for antiviral drug development to aid preparation for future coronavirus pandemics.

18.
Acta Crystallogr F Struct Biol Commun ; 78(Pt 7): 281-288, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35787556

RESUMEN

KAMO and BLEND provide particularly effective tools to automatically manage the merging of large numbers of data sets from serial crystallography. The requirement for manual intervention in the process can be reduced by extending BLEND to support additional clustering options such as the use of more accurate cell distance metrics and the use of reflection-intensity correlation coefficients to infer `distances' among sets of reflections. This increases the sensitivity to differences in unit-cell parameters and allows clustering to assemble nearly complete data sets on the basis of intensity or amplitude differences. If the data sets are already sufficiently complete to permit it, one applies KAMO once and clusters the data using intensities only. When starting from incomplete data sets, one applies KAMO twice, first using unit-cell parameters. In this step, either the simple cell vector distance of the original BLEND or the more sensitive NCDist is used. This step tends to find clusters of sufficient size such that, when merged, each cluster is sufficiently complete to allow reflection intensities or amplitudes to be compared. One then uses KAMO again using the correlation between reflections with a common hkl to merge clusters in a way that is sensitive to structural differences that may not have perturbed the unit-cell parameters sufficiently to make meaningful clusters. Many groups have developed effective clustering algorithms that use a measurable physical parameter from each diffraction still or wedge to cluster the data into categories which then can be merged, one hopes, to yield the electron density from a single protein form. Since these physical parameters are often largely independent of one another, it should be possible to greatly improve the efficacy of data-clustering software by using a multi-stage partitioning strategy. Here, one possible approach to multi-stage data clustering is demonstrated. The strategy is to use unit-cell clustering until the merged data are sufficiently complete and then to use intensity-based clustering. Using this strategy, it is demonstrated that it is possible to accurately cluster data sets from crystals that have subtle differences.


Asunto(s)
Algoritmos , Programas Informáticos , Análisis por Conglomerados , Cristalografía por Rayos X , Proteínas/química
19.
Sci Rep ; 12(1): 12197, 2022 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-35842458

RESUMEN

Severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2), which causes coronavirus disease 2019 (COVID-19), threatens global public health. The world needs rapid development of new antivirals and vaccines to control the current pandemic and to control the spread of the variants. Among the proteins synthesized by the SARS-CoV-2 genome, main protease (Mpro also known as 3CLpro) is a primary drug target, due to its essential role in maturation of the viral polyproteins. In this study, we provide crystallographic evidence, along with some binding assay data, that three clinically approved anti hepatitis C virus drugs and two other drug-like compounds covalently bind to the Mpro Cys145 catalytic residue in the active site. Also, molecular docking studies can provide additional insight for the design of new antiviral inhibitors for SARS-CoV-2 using these drugs as lead compounds. One might consider derivatives of these lead compounds with higher affinity to the Mpro as potential COVID-19 therapeutics for further testing and possibly clinical trials.


Asunto(s)
Tratamiento Farmacológico de COVID-19 , Antivirales/uso terapéutico , Proteasas 3C de Coronavirus , Cisteína Endopeptidasas/metabolismo , Hepacivirus/metabolismo , Humanos , Simulación del Acoplamiento Molecular , Inhibidores de Proteasas/química , SARS-CoV-2 , Proteínas no Estructurales Virales/genética
20.
bioRxiv ; 2021 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-33972941

RESUMEN

The COVID-19 pandemic, instigated by the SARS-CoV-2 coronavirus, continues to plague the globe. The SARS-CoV-2 main protease, or Mpro, is a promising target for development of novel antiviral therapeutics. Previous X-ray crystal structures of Mpro were obtained at cryogenic temperature or room temperature only. Here we report a series of high-resolution crystal structures of unliganded Mpro across multiple temperatures from cryogenic to physiological, and another at high humidity. We interrogate these datasets with parsimonious multiconformer models, multi-copy ensemble models, and isomorphous difference density maps. Our analysis reveals a temperature-dependent conformational landscape for Mpro, including mobile solvent interleaved between the catalytic dyad, mercurial conformational heterogeneity in a key substrate-binding loop, and a far-reaching intramolecular network bridging the active site and dimer interface. Our results may inspire new strategies for antiviral drug development to counter-punch COVID-19 and combat future coronavirus pandemics.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA