Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Strahlenther Onkol ; 197(3): 198-208, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32561941

RESUMEN

BACKGROUND AND PURPOSE: High-dose 6­MV radiotherapy may cause cardiac implantable electronic devices (CIEDs) to malfunction. To assess CIED malfunctions resulting from direct exposure up to 10 Gy, 100 pacemakers (PMs) and 40 implantable cardioverter-defibrillators (ICDs) were evaluated. MATERIALS AND METHODS: CIEDs underwent baseline interrogation. In ICDs, antitachycardia therapies were disabled via the programmer while the detection windows were left enabled. A computed tomography (CT) scan was performed to build the corresponding treatment plan. CIEDs were "blinded" and randomized to receive single doses of either 2, 5, or, 10 Gy via a 6-MV linear accelerator (linac) in a water phantom. Twenty-two wireless telemetry-enabled CIEDs underwent a real-time session, and their function was recorded by the video camera in the bunker. The CIEDs were interrogated after exposure and once monthly for 6 months. RESULTS: During exposure, regardless of dose, 90.9% of the CIEDs recorded electromagnetic interference, with 6 ICDs (27.3%) reporting pacing inhibition and inappropriate arrhythmia detections. After exposure, a backup reset was observed in 1 PM (0.7% overall, 1% among PMs), while 7 PMs (5% overall, 7% among PMs) reported battery issues (overall immediate malfunction rate was 5.7%). During follow-up, 4 PMs (2.9% overall; 4% among PMs) and 1 ICD (0.7% overall; 2.5% among ICDs) reported abnormal battery depletion, and 1 PM (0.7% overall; 1% among PMs) reported a backup reset (overall late malfunction rate was 4.3%). CONCLUSION: Apart from transient electromagnetic interference, last-generation CIEDs withstood direct 6­MV exposure up to 10 Gy. Permanent battery or software errors occurred immediately or later only in less recent CIEDs.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Falla de Equipo , Marcapaso Artificial/efectos adversos , Dosificación Radioterapéutica , Análisis de Falla de Equipo , Humanos , Radioterapia/efectos adversos
2.
Sci Rep ; 10(1): 3230, 2020 02 24.
Artículo en Inglés | MEDLINE | ID: mdl-32094376

RESUMEN

The incidence of atrial fibrillation (AF) in cryptogenic stroke (CS) patients has been studied in carefully controlled clinical trials, but real-world data are limited. We investigated the incidence of AF in clinical practice among CS patients with an insertable cardiac monitor (ICM) placed for AF detection. Patients with CS admitted to our Stroke Unit were included in the study; they received an ICM and were monitored for up to 3 years for AF detection. All detected AF episodes of at least 120 sec were considered. From March 2016 to March 2019, 58 patients (mean age 68.1 ± 9.3 years, 67% male) received an ICM to detect AF after a CS. No patients were lost to follow-up. AF was detected in 24 patients (41%, AF group mean age 70.8 ± 9.4 years, 62% male) after a mean time of 6 months from ICM (ranging from 2 days to 2 years) and 8 months after CS (ranging from 1 month to 2 years). In these AF patients, anticoagulant treatment was prescribed and nobody had a further stroke. In conclusion, AF episodes were detected via continuous monitoring with ICMs in 41% of implanted CS patients. AF in CS patients is asymptomatic and difficult to diagnose by strategies based on intermittent short-term recordings. Therefore, we suggest that ICMs should be part of daily practice in the evaluation of CS patients.


Asunto(s)
Fibrilación Atrial/complicaciones , Monitoreo Fisiológico/instrumentación , Accidente Cerebrovascular/complicaciones , Anciano , Anticoagulantes/uso terapéutico , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/tratamiento farmacológico , Electrocardiografía Ambulatoria , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Implantación de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/tratamiento farmacológico , Resultado del Tratamiento
3.
Clin Case Rep ; 6(4): 574-577, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29636916

RESUMEN

Subcutaneous implantable cardioverter defibrillator (S-ICD) is easy to implant, with poor risks of the patient. However, fat is a poor current conductor and increases defibrillation threshold. As shock impedance alone should not be considered a good efficacy predictor of an S-ICD system, an X-ray latero-lateral view for lead position should be achieved.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA