Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Lasers Med Sci ; 39(1): 213, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39129047

RESUMEN

The aim of this study is to evaluate the effect of different irrigation activation methods on root canal sealer penetration in teeth with simulated internal root resorption (IRR) and calcium hydroxide (CH) applied using a confocal laser scanning microscope (CLSM). 60 incisors with a single root and a single canal were included in the study. IRR cavities were created in the middle third of the root canal, and CH was placed. The samples were randomly divided into 4 groups (n = 15) according to the irrigation activation method to be tested: standard needle irrigation (SNI), sonic activation (EDDY), photon-induced photoacoustic flow (PIPS), and shock wave enhanced emission photoacoustic flow (SWEEPS). After irrigation activation applications, the root canals were obturated. Sections of 1.0 ± 0.1 mm were taken from the apical, middle, and coronal regions of each sample. The penetration area (µm2) and maximum penetration depth (µm) of the root canal sealer were examined by CLSM and analyzed using ImageJ software. Statistical analysis was performed with a one-way ANOVA and post-hoc Tukey test at the P < 0.05 significance level. Among all irrigation activation methods tested, both the penetration area and maximum penetration depth of the root canal sealer were greater in the coronal region than in the apical region (p < 0.05). In the IRR region, there was no difference in terms of maximum penetration depth between PIPS and SWEEPS (p > 0.05), it was highest in SWEEPS (p < 0.05). PIPS and SWEEPS were better than other irrigation activation methods in the penetration of root canal sealer in the resorption areas of teeth with IRR.


Asunto(s)
Hidróxido de Calcio , Microscopía Confocal , Resorción Radicular , Humanos , Materiales de Obturación del Conducto Radicular , Irrigación Terapéutica/métodos , Irrigación Terapéutica/instrumentación , Irrigantes del Conducto Radicular/administración & dosificación , Preparación del Conducto Radicular/métodos , Preparación del Conducto Radicular/instrumentación , Incisivo
2.
Restor Dent Endod ; 42(3): 224-231, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28808639

RESUMEN

OBJECTIVES: To determine the actual revolutions per minute (rpm) values and compare the cyclic fatigue life of Reciproc (RPC, VDW GmbH), WaveOne (WO, Dentsply Maillefer), and TF Adaptive (TFA, Axis/SybronEndo) nickel-titanium (NiTi) file systems using high-speed camera. MATERIALS AND METHODS: Twenty RPC R25 (25/0.08), 20 WO Primary (25/0.08), and 20 TFA ML 1 (25/0.08) files were employed in the present study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which has an artificial stainless steel canal with a 60° angle of curvature and a 5-mm radius of curvature. The files were divided into 3 groups (group 1, RPC R25 [RPC]; group 2, WO Primary [WO]; group 3, TF Adaptive ML 1 [TFA]). All the instruments were rotated until fracture during the cyclic fatigue test and slow-motion videos were captured using high-speed camera. The number of cycles to failure (NCF) was calculated. The data were analyzed statistically using one-way analysis of variance (ANOVA, p < 0.05). RESULTS: The slow-motion videos were indicated that rpm values of the RPC, WO, and TFA groups were 180, 210, and 425, respectively. RPC (3,464.45 ± 487.58) and WO (3,257.63 ± 556.39) groups had significantly longer cyclic fatigue life compared with TFA (1,634.46 ± 300.03) group (p < 0.05). There was no significant difference in the mean length of the fractured fragments. CONCLUSIONS: Within the limitation of the present study, RPC and WO NiTi files showed significantly longer cyclic fatigue life than TFA NiTi file.

3.
J Conserv Dent ; 19(1): 68-71, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26957797

RESUMEN

BACKGROUND/AIM: To compare apically extruded debris using ProTaper Universal (PTU), ProTaper Next (PTN), WaveOne (WO), Twisted File (TF), M-Two (MT), and Revo-S (RS) after determining the working length (WL) with root ZX. MATERIALS AND METHODS: Seventy-two teeth were selected. The WL determination was performed with root ZX. The teeth were divided into six experimental groups, randomly. In groups, root canals were prepared with PTU to size F4/0.06, with PTN to size X4/0.06, with WO to size 40/0.08, with TF to size 40/0.04, with MT to size 40/0.06, and with RS to size AS40/0.06. After preparations were completed, final irrigation was performed with 2 mL distilled water, and a total of 10 mL of distilled water was used in each tooth. Tubes were stored in an incubator at 68°C for 5 days to evaporate the distilled water before weighing the dry debris. Data were analyzed by the Mann-Whitney U-test. RESULTS: The RS group led to the highest amount of extruded debris, however, WO led to the least amount of extruded debris. There was no statistically difference among the groups (P > 0.05). CONCLUSIONS: The authors conclude that the results obtained might depend on the apex locator used to determine the WL.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA