Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Am Heart J ; 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38838970

RESUMEN

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, p=0.33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 p=0.46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, p=0.04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, p=0.02), reduced SVi (34.2 vs 38 ml/m2, p<0.01) and transaortic flow rate (190.6 vs 211 ml/s, p<0.01). At pre-discharge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, p<0.01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, p=0.03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs.44 IQR 35-59 in those without, p=0.02)). No evidence of a significant impact of PPM on overall (p=0.71) and CV (p=0.70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, p=0.03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, p<0.001) and LVOT diameter (OR 0.79, 0.65-0.95, p=0.01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

2.
Eur J Clin Invest ; : e14188, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38396359

RESUMEN

BACKGROUND: Metabolic dysfunction associated steatotic liver disease (MASLD) is associated with an increased risk of coronary artery disease. Computed Tomography Coronary Angiography (CTCA) can assess both the extent and the features of coronary plaques. We aimed to gather evidence about the prevalence and features of coronary plaques among MASLD patients. METHODS: PubMed, Scopus, and Google Scholar databases were searched for randomized controlled trials and adjusted observational studies assessing the prevalence and features of coronary plaques by means of CTCA in MASLD patients as compared with a control group. The prevalence of coronary stenosis (defined as >30% and >50% diameter of stenosis), of increasing coronary artery calcium (CAC) score and of high-risk features (namely low-attenuation plaques, napkin ring sign, spotty calcification and positive remodelling) in MASLD patients were the endpoints of interest. RESULTS: Twenty-four observational studies were included. MASLD was associated with an increased prevalence of critical coronary stenosis compared with controls (odds ratio [OR] 1.54, 95%CI 1.23-1.93). Increased values of CAC score were observed in MASLD patients (OR 1.35, 95%CI 1.02-1.78 and OR 2.26, 95%CI 1.57-3.23 for CAC score 0-100 and >100, respectively). An increased risk of 'high-risk' coronary plaques was observed in MASLD patients (OR 2.13, 95%CI 1.42-3.19). As high-risk features plaques, a higher prevalence of positive remodelling and spotty calcification characterize MASLD patients (OR 2.92, 95%CI 1.79-4.77 and OR 2.96, 95%CI 1.22-7.20). CONCLUSIONS: Patients with MASLD are at increased risk of developing critical coronary stenosis and coronary plaques characterized by high-risk features as detected by CTCA.

3.
Eur Radiol ; 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38844620

RESUMEN

OBJECTIVES: To perform a systematic review and meta-analysis of studies investigating the diagnostic value of cardiac magnetic resonance (CMR) features for arrhythmic risk stratification in mitral valve prolapse (MVP) patients. MATERIALS AND METHODS: EMBASE, PubMed/MEDLINE, and CENTRAL were searched for studies reporting MVP patients who underwent CMR with assessment of: left ventricular (LV) size and function, mitral regurgitation (MR), prolapse distance, mitral annular disjunction (MAD), curling, late gadolinium enhancement (LGE), and T1 mapping, and reported the association with arrhythmia. The primary endpoint was complex ventricular arrhythmias (co-VAs) as defined by any non-sustained ventricular tachycardia, sustained ventricular tachycardia, ventricular fibrillation, or aborted sudden cardiac death. Meta-analysis was performed when at least three studies investigated a CMR feature. PROSPERO registration number: CRD42023374185. RESULTS: The meta-analysis included 11 studies with 1278 patients. MR severity, leaflet length/thickness, curling, MAD distance, and mapping techniques were not meta-analyzed as reported in < 3 studies. LV end-diastolic volume index, LV ejection fraction, and prolapse distance showed small non-significant effect sizes. LGE showed a strong and significant association with co-VA with a LogORs of 2.12 (95% confidence interval (CI): [1.00, 3.23]), for MAD the log odds-ratio was 0.95 (95% CI: [0.30, 1.60]). The predictive accuracy of LGE was substantial, with a hierarchical summary ROC AUC of 0.83 (95% CI: [0.69, 0.91]) and sensitivity and specificity rates of 0.70 (95% CI: [0.41, 0.89]) and 0.80 (95% CI: [0.67, 0.89]), respectively. CONCLUSIONS: Our study highlights the role of LGE as the key CMR feature for arrhythmia risk stratification in MVP patients. MAD might complement arrhythmic risk stratification. CLINICAL RELEVANCE STATEMENT: LGE is a key factor for arrhythmogenic risk in MVP patients, with additional contribution from MAD. Combining MRI findings with clinical characteristics is critical for evaluating and accurately stratifying arrhythmogenic risk in MVP patients. KEY POINTS: MVP affects 2-3% of the population, with some facing increased risk for arrhythmia. LGE can assess arrhythmia risk, and MAD may further stratify patients. CMR is critical for MVP arrhythmia risk stratification, making it essential in a comprehensive evaluation.

4.
Artif Organs ; 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38803239

RESUMEN

BACKGROUND: Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled. METHODS: Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied. RESULTS: Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality. CONCLUSIONS: Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.

5.
Catheter Cardiovasc Interv ; 102(4): 620-630, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37668085

RESUMEN

BACKGROUND: It is still unclear the impact of diabetes mellitus (DM) in complex coronary lesions treated with percutaneous coronary intervention (PCI) which themselves are at increased incidence of adverse events. METHODS: BIFURCAT registry encompassed patients treated with PCI for coronary bifurcation lesion from the COBIS III and the RAIN registry. The primary endpoint was the occurrence of major cardiovascular adverse event (MACE), a composite and mutual exclusive of all-cause death or myocardial infarction (MI) or target-lesion revascularization (TLR). A total of 5537 patients were included in the analysis and 1834 (33%) suffered from DM. RESULTS: After a median follow-up of 21 months, diabetic patients had a higher incidence of MACE (17% vs. 9%, p < 0.001), all-cause mortality (9% vs. 4%, p < 0.001), TLR (5% vs. 3%, p = 0.001), MI (4% vs. 2%, p < 0.001), and stent thrombosis (ST) (2% vs. 1%, p = 0.007). After multivariate analysis, diabetes remained significantly associated with MACE (hazard ratio [HR]: 1.37; confidence interval [CI]: 1.13-1.65; p = 0.001), all-cause death (HR: 1.65; 95% CI: 1.24-2.19, p = 0.001), TLR (HR: 1.45; CI: 1.03-2.04; p = 0.031) and ST (HR: 1.73, CI: 1.04-2.88; p = 0.036), but not with MI (HR: 1.34; CI: 0.93-1.92; p = 0.11). Among diabetics, chronic kidney disease (HR: 2.99; CI: 2.21-4.04), baseline left ventricular ejection fraction (HR: 0.98; CI: 0.97-0.99), femoral access (HR: 1.62; CI: 1.23-2.15), left main coronary artery (HR: 1.44; CI: 1.06-1.94), main branch diameter (HR: 0.79; CI: 0.66-0.94) and final kissing balloon (HR: 0.70; CI: 0.52-0.93) were independent predictors of MACE at follow-up. CONCLUSIONS: Patients with DM treated with PCI for coronary bifurcations have a worse prognosis due to higher incidence of MACE, all-cause mortality, TLR and ST compared to the non-diabetics.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Intervención Coronaria Percutánea/efectos adversos , Volumen Sistólico , Resultado del Tratamiento , Factores de Riesgo , Stents Liberadores de Fármacos/efectos adversos , Función Ventricular Izquierda , Infarto del Miocardio/etiología , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Sistema de Registros , Estudios Retrospectivos
6.
Eur Radiol ; 2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-38078997

RESUMEN

Mitral valve prolapse (MVP) is the most common valve disease in the western world and recently emerged as a possible substrate for sudden cardiac death (SCD). It is estimated an annual risk of sudden cardiac death of 0.2 to 1.9% mostly caused by complex ventricular arrhythmias (VA). Several mechanisms have been recognized as potentially responsible for arrhythmia onset in MVP, resulting from the combination of morpho-functional abnormality of the mitral valve, structural substrates (regional myocardial hypertrophy, fibrosis, Purkinje fibers activity, inflammation), and mechanical stretch. Echocardiography plays a central role in MVP diagnosis and assessment of severity of regurgitation. Several abnormalities detectable by echocardiography can be prognostic for the occurrence of VA, from morphological alteration including leaflet redundancy and thickness, mitral annular dilatation, and mitral annulus disjunction (MAD), to motion abnormalities detectable with "Pickelhaube" sign. Additionally, speckle-tracking echocardiography may identify MVP patients at higher risk for VA by detection of increased mechanical dispersion. On the other hand, cardiac magnetic resonance (CMR) has the capability to provide a comprehensive risk stratification combining the identification of morphological and motion alteration with the detection of myocardial replacement and interstitial fibrosis, making CMR an ideal method for arrhythmia risk stratification in patients with MVP. Finally, recent studies have suggested a potential role in risk stratification of new techniques such as hybrid PET-MR and late contrast enhancement CT. The purpose of this review is to provide an overview of the mitral valve prolapse syndrome with a focus on the role of imaging in arrhythmic risk stratification. CLINICAL RELEVANCE STATEMENT: Mitral valve prolapse is the most frequent valve condition potentially associated with arrhythmias. Imaging has a central role in the identification of anatomical, functional, mechanical, and structural alterations potentially associated with a higher risk of developing complex ventricular arrhythmia and sudden cardiac death. KEY POINTS: • Mitral valve prolapse is a common valve disease potentially associated with complex ventricular arrhythmia and sudden cardiac death. • The mechanism of arrhythmogenesis in mitral valve prolapse is complex and multifactorial, due to the interplay among multiple conditions including valve morphological alteration, mechanical stretch, myocardial structure remodeling with fibrosis, and inflammation. • Cardiac imaging, especially echocardiography and cardiac magnetic resonance, is crucial in the identification of several features associated with the potential risk of serious cardiac events. In particular, cardiac magnetic resonance has the advantage of being able to detect myocardial fibrosis which is currently the strongest prognosticator.

7.
Lancet ; 397(10270): 199-207, 2021 01 16.
Artículo en Inglés | MEDLINE | ID: mdl-33453782

RESUMEN

BACKGROUND: The accuracy of current prediction tools for ischaemic and bleeding events after an acute coronary syndrome (ACS) remains insufficient for individualised patient management strategies. We developed a machine learning-based risk stratification model to predict all-cause death, recurrent acute myocardial infarction, and major bleeding after ACS. METHODS: Different machine learning models for the prediction of 1-year post-discharge all-cause death, myocardial infarction, and major bleeding (defined as Bleeding Academic Research Consortium type 3 or 5) were trained on a cohort of 19 826 adult patients with ACS (split into a training cohort [80%] and internal validation cohort [20%]) from the BleeMACS and RENAMI registries, which included patients across several continents. 25 clinical features routinely assessed at discharge were used to inform the models. The best-performing model for each study outcome (the PRAISE score) was tested in an external validation cohort of 3444 patients with ACS pooled from a randomised controlled trial and three prospective registries. Model performance was assessed according to a range of learning metrics including area under the receiver operating characteristic curve (AUC). FINDINGS: The PRAISE score showed an AUC of 0·82 (95% CI 0·78-0·85) in the internal validation cohort and 0·92 (0·90-0·93) in the external validation cohort for 1-year all-cause death; an AUC of 0·74 (0·70-0·78) in the internal validation cohort and 0·81 (0·76-0·85) in the external validation cohort for 1-year myocardial infarction; and an AUC of 0·70 (0·66-0·75) in the internal validation cohort and 0·86 (0·82-0·89) in the external validation cohort for 1-year major bleeding. INTERPRETATION: A machine learning-based approach for the identification of predictors of events after an ACS is feasible and effective. The PRAISE score showed accurate discriminative capabilities for the prediction of all-cause death, myocardial infarction, and major bleeding, and might be useful to guide clinical decision making. FUNDING: None.


Asunto(s)
Síndrome Coronario Agudo/complicaciones , Conjuntos de Datos como Asunto , Aprendizaje Automático , Mortalidad , Complicaciones Posoperatorias , Adulto , Toma de Decisiones Clínicas , Femenino , Hemorragia/etiología , Humanos , Masculino
8.
J Card Fail ; 28(2): 259-269, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34509597

RESUMEN

BACKGROUND: Right ventricular dysfunction (RVD) is a major issue in patients with advanced heart failure because it precludes the implantation of left ventricular assist device, usually leaving heart transplantation (HTx) as the only available treatment option. The pulmonary artery pulsatility index (PAPi) is a hemodynamic parameter integrating information of right ventricular function and of pulmonary circulation. Our aim is to evaluate the association of preoperative RVD, hemodynamically defined as a low PAPi, with post-HTx survival. METHODS AND RESULTS: Consecutive adult HTx recipient at 2 Italian transplant centers between 2000 and 2018 with available data on pre-HTx right heart catheterization were included retrospectively. RVD was defined as a value of PAPi lower than the 25th percentile of the study population. The association of RVD with the 1-year post-HTx mortality and other secondary end points were evaluated. Multivariate logistic regression was used to adjust for clinical and hemodynamic variables. Analyses stratified by pulmonary vascular resistance (PVR) status (≥3 Woods units vs <3 Woods units) were also performed. Among 657 HTx recipients (female 31.1%, age 53 ± 11 years), patients with pre-HTx RVD (PAPi of <1.68) had significantly lower 1-year survival rates (77.8% vs 87.1%, P = .005), also after adjusting for estimated glomerular filtration rate, total bilirubin, PVR, serum sodium, inotropes, and mechanical circulatory support at HTx (hazard ratio 2.0, 95% confidence interval, 1.3-3.1). RVD was also associated with post-HTx renal replacement therapy (hazard ratio 2.0, 95% confidence interval 1.05-3.30) and primary graft dysfunction (hazard ratio 1.7, , 95% confidence interval 1.02-3.30). When stratifying patients by estimated PVR status, RVD was associated with worse 1-year survival among patients with normal PVR (76.9% vs 88.3%, P = .003), but not in those with increased PVR (78.6% vs 83.2%, P = .49). CONCLUSIONS: Preoperative RVD, evaluated through PAPi, is associated with mortality and morbidity after HTx, providing incremental prognostic value over traditional clinical and hemodynamic parameters.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Disfunción Ventricular Derecha , Adulto , Femenino , Trasplante de Corazón/efectos adversos , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Función Ventricular Derecha
9.
Catheter Cardiovasc Interv ; 99(7): 1976-1983, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35419933

RESUMEN

BACKGROUND: In contemporary Cardiac Intensive Care Unit (CICU), bedside intra-aortic balloon pump (IABP) insertion under echocardiographic guidance may be an attractive option for selected patients with cardiogenic shock (CS). Currently available data on this approach are limited. AIM: This study aimed to assess the feasibility and safety of bedside IABP insertion, as compared to fluoroscopic-guided insertion in the Catheterization Laboratory (CathLab), and to describe the clinical features of patients receiving bedside IABP insertion using a standardized technique in real-world CICU practice. METHODS: We prospectively evaluated all patients admitted the CICU who received transfemoral IABP between June 2020 and October 2021. The overall study cohort was divided according to implant strategy in bedside and CathLab groups. The primary outcome was correct radiographic IABP positioning at the first bedside chest X-ray obtained after insertion. Secondary outcomes included IABP-related complications. RESULTS: Among 115 patients, bedside IABP insertion was performed in 35 (30.4%) cases, mainly presenting with CS-related to acute decompensated heart failure (ADHF) (68.6 vs 33.8%; p < 0.001), with lower LVEF, higher proportion of right ventricular involvement and higher need of inotropes/vasopressors, compared to those receiving CathLab insertion. Bedside IABP insertion resulted feasible and safe, with similar rates of correct IABP positioning (82.9 vs. 82.5%; p = 0.963) and IABP-related major vascular complications (5.7 vs. 5.0%; p = 0.874), as compared to CathLab positioning. CONCLUSION: This study suggests the feasibility and safety of bedside IABP insertion, which could be of relevant interest in patients with ADHF-related CS who may not need coronary angiography or other urgent CathLab procedures.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/etiología , Corazón Auxiliar/efectos adversos , Humanos , Unidades de Cuidados Intensivos , Contrapulsador Intraaórtico/efectos adversos , Contrapulsador Intraaórtico/métodos , Estudios Retrospectivos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 99(1): 27-36, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34028964

RESUMEN

OBJECTIVE: Aim of this study is to evaluate short term safety and efficacy of Impella in high risk percutaneous coronary intervention (HR-PCI) population. BACKGROUND: While several studies demonstrated the clinical significance of Impella in HR-PCI, few data exist about its impact on short term outcome. METHODS: All studies reporting short term outcomes of PCI with any Impella device were included. The primary endpoint was either in-hospital or 30-day mortality, while vascular complications, post-procedural stroke, post-procedural dialysis and bleeding complications were assessed as secondary outcomes. RESULTS: Nine studies with 7448 patients were included. Median age was 69.5 years old (67-73), with a mean ejection fraction of 29.7% (20%-39%) and a Syntax score of 30.2 (25. 5-33, interquartile [IQR]). Impella 2.5 was the most commonly used axial flow pump used to support these PCIs (88.7%). In-hospital death was observed in 5.09% of patients (95% confidence interval [CI] 3.69-6.49, I2  = 78%), while vascular complications in 2.53% of patients (1.07-4.00, I2  = 89%) and post-procedural stroke in 2.77% of patients (0.50-6.05, I2  = 98%). Major bleeding occurred in 5.98% of patients (3.66-8.31, I2  = 90%) and post-procedural dialysis in 4.44% of patients (1.50-7.37, I2  = 93% all CI 93%). CONCLUSION: Use of Impella in high risk PCI appears to have an acceptable rate of complication, especially regarding vascular complications and major bleedings.


Asunto(s)
Corazón Auxiliar , Intervención Coronaria Percutánea , Anciano , Corazón Auxiliar/efectos adversos , Mortalidad Hospitalaria , Humanos , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 100(1): 122-130, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35485723

RESUMEN

INTRODUCTION: Despite limited to short and midterm outcomes, valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) has emerged as a valid alternative to re-surgical aortic valve replacement (re-SAVR) for high- and intermediate-risk patients with degenerated surgical bioprosthesis. METHODS: All studies comparing multivariate adjustment between ViV TAVI and re-SAVR were screened. The primary end-points were all-cause and cardiovascular (CV) mortality at 30 days and at Midterm follow-up. Short-term complications were the secondary endpoints. RESULTS: We obtained data from 11 studies, encompassing 8570 patients, 4224 undergoing ViV TAVI, and 4346 re-SAVR. Four studies included intermediate-risk patients and seven high-risk patients. 30-day all-cause and CV mortality were significantly lower in ViV (odds ratio [OR] 0.43, 95% confidence intervals [CIs] 0.29-0.64 and OR 0.44, 0.26-0.73 respectively), while after a mean follow-up of 717 (180-1825) days, there was no difference between the two groups (OR 1.04, 0.87-1.25 and OR 1.05, 0.78-1.43, respectively). The risk of stroke (OR 1.03, 0.59-1.82), MI (OR 0.70, 0.34-1.44), major vascular complications (OR 0.92, 0.50-1.67), and permanent pacemaker implantation (OR 0.67, 0.36-1.25) at 30 days did not differ, while major bleedings and new-onset atrial fibrillation were significantly lower in ViV patients (OR 0.41, 0.25-0.67 and OR 0.23, 0.12-0.42, respectively, all 95% CIs). CONCLUSIONS: In high- and intermediate-risk patients with degenerated surgical bioprostheses, ViV TAVI is associated with reduced short-term mortality, compared with re-SAVR. Nevertheless, no differences were found in all-cause and CV mortality at midterm follow-up. PROSPERO CRD42021226488.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
12.
Eur Radiol ; 32(8): 5189-5200, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35192010

RESUMEN

OBJECTIVE: To evaluate the diagnostic accuracy of coronary computed tomography angiography (CCTA) for the evaluation of obstructive coronary artery disease (CAD) in patients referred for transcatheter aortic valve implantation (TAVI). METHODS: EMBASE, PubMed/MEDLINE, and CENTRAL were searched for studies reporting accuracy of CCTA for the evaluation of obstructive CAD compared with invasive coronary angiography (ICA) as the reference standard. QUADAS-2 tool was used to assess the risk of bias. A bivariate random effects model was used to analyze, pool, and plot the diagnostic performance measurements across studies. Pooled sensitivity, specificity, positive ( + LR) and negative (-LR) likelihood ratio, diagnostic odds ratio (DOR), and hierarchical summary ROC curve (HSROC) were evaluated. Prospero registration number: CRD42021252527. RESULTS: Fourteen studies (2533 patients) were included. In the intention-to-diagnose patient-level analysis, sensitivity and specificity for CCTA were 97% (95% CI: 94-98%) and 68% (95% CI: 56-68%), respectively, and + LR and -LR were 3.0 (95% CI: 2.1-4.3) and 0.05 (95% CI: 0.03 - 0.09), with DOR equal to 60 (95% CI: 30-121). The area under the HSROC curve was 0.96 (95% CI: 0.94-0.98). No significant difference in sensitivity was found between single-heartbeat and other CT scanners (96% (95% CI: 90 - 99%) vs. 97% (95% CI: 94-98%) respectively; p = 0.37), whereas the specificity of single-heartbeat scanners was higher (82% (95% CI: 66-92%) vs. 60% (95% CI: 46 - 72%) respectively; p < 0.0001). Routine CCTA in the pre-TAVI workup could save 41% (95% CI: 34 - 47%) of ICAs if a disease prevalence of 40% is assumed. CONCLUSIONS: CCTA proved an excellent diagnostic accuracy for assessing obstructive CAD in patients referred for TAVI; the use of single-heartbeat CT scanners can further improve these findings. KEY POINTS: • CCTA proved to have an excellent diagnostic accuracy for assessing obstructive CAD in patients referred for TAVI. • Routine CCTA in the pre-TAVI workup could save more than 40% of ICAs. • Single-heartbeat CT scanners had higher specificity than others in the assessment of obstructive CAD in patients referred for TAVI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Tomografía Computarizada por Rayos X/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
13.
Catheter Cardiovasc Interv ; 98(3): E365-E369, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33851771

RESUMEN

AIM: Coronary sinus (CS) reducer implantation is associated with symptomatic relief of patients with refractory angina. However, 15% to 30% of the patients do not respond to this treatment. Aim if this study was to evaluate the effect of CS size in the effectiveness of the device. METHODS: Prior to device implantation and at 4-month resting ventricular function was assessed by stress cardiac magnetic resonance. Ischemia was assessed by the myocardial perfusion reserve index (MPRI). RESULTS: Fifteen patients (66 ± 10 years) underwent successful CS Reducer implantation, with improvements in angina class and exercise tolerance. Patients with a smaller CS size (<5.8 mm) presented a significantly higher percentage increase in MPRI (63 ± 51 vs 9 ± 30%, P = .03) and a higher reduction in left ventricle end-diastolic volumes. CONCLUSIONS: Greater benefits, in terms of ischemia improvement, after CS Reducer implantation were seen in patients with smaller CS sizes, suggesting a potential mechanism underlying the observed rates of reducer non-responsiveness.


Asunto(s)
Seno Coronario , Angina de Pecho , Seno Coronario/diagnóstico por imagen , Tolerancia al Ejercicio , Humanos , Isquemia , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 98(1): E18-E23, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33315297

RESUMEN

BACKGROUND: Clinical benefits of FFR (Fraction Flow Reserve) driven CABG (Coronary Artery Bypass Graft) remain to be established. METHODS: All randomized controlled trials (RCTs) and observational studies with multivariable adjustement were included. MACE (Major Adverse Cardiac Events) was the primary end point, while its single components (death, myocardial infarction, and total vessel revascularization [TVR]) along with number of anastomoses, on pump procedures and graft occlusion at angiographic follow-up were the secondary ones. Each analysis was stratified for RCTs versus observational studies. RESULTS: Four studies (two RCTs and two observational) were included, enrolling 983 patients, 542 angio-guided and 441 FFR-guided. Mean age was 68.45 years, 79% male, with a mean EuroSCORE I of 2.7. Coronary lesions were located in 37% of patients in the left anterior descending artery, 32% in the circumflex artery, and 26% in the right coronary artery. After a mean follow-up of 40 months, risk of MACE did not differ (OR 0.86 [0.63-1.18]) as that of all cause death (OR 0.86 [0.59-1.25]), MI (OR 0.57 [0.30-1.11]) and TVR (OR 1.10 [0.65-1.85]). FFR-driven CABG reduced on-pump procedures (OR 0.58 [0.35-0.93]) and number of anastomoses (-0.40 [-0.80: -0.01]) while incidence of graft occlusion at follow-up did not differ (OR 0.59 [0.30-1.15], all CI 95%). CONCLUSION: Fraction flow reserve driven CABG reduced the number of anastomoses and of on-pump procedures without increasing risk of MACE and without reducing graft occlusion at angiographic follow-up. ID CRD42020211945.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Anciano , Angiografía Coronaria , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 97(4): 581-588, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32790145

RESUMEN

BACKGROUND: The optimal antithrombotic regimen in patients with a concomitant indication for oral anticoagulation (OAT) presenting with acute coronary syndrome (ACS) or undergoing percutaneous coronary intervention (PCI) remains unclear. OBJECTIVES: To perform a network meta-analysis of all randomized controlled trials (RCTs) evaluating different antithrombotic regimens among patients with ACS or undergoing PCI requiring OAT. METHODS: Network meta-analysis was performed in a frequentist framework. Antithrombotic regimens were categorized by OAC type (vitamin K antagonist-based [VKA]; non-VKA OAT [NOAC]) and antiplatelet agents (P2Y inhibitor only: dual therapy [DAT]; P2Y plus aspirin: triple therapy [TAT]). Safety outcomes were Thrombolysis in Myocardial Infarction (TIMI) major bleeding and intracranial hemorrhage (ICH). Efficacy outcomes were cardiovascular death, myocardial infarction, stroke and stent-thrombosis (ST). RESULTS: Five RCTs were included, encompassing 10,797 patients (atrial fibrillation 69-100%, ACS 28-62%, PCI 77-100%). Both VKA and NOAC-based DAT regimens reduced the occurrence of TIMI major bleeding compared to VKA TAT (VKA DAT: RR 0.62, 95% CI 0.39-0.98; NOAC DAT: RR 0.52, 95% CI 0.39-0.70). Nevertheless, only NOAC DAT significantly reduced the occurrence of ICH compared to VKA TAT (RR 0.33, 95% CI 0.17-0.64). Ischemic outcomes were similar among the four treatment regimens. However, numerical, potentially clinically important, higher ST occurrence was observed for NOAC DAT as compared to both VKA TAT (1.50, 95% confidence interval [CI] 0.96-2.33) and NOAC TAT (1.86, 95% CI 0.93-3.73). CONCLUSION: DAT regimens present the highest safety profile among antithrombotic strategies, with a NOAC-specific impact on ICH reduction. NOAC DAT might entail clinically important higher ST occurrence, warranting a case-by-case comprehensive evaluation that integrates patient- and procedure-related residual ischemic risk with the patient-specific bleeding risk.


Asunto(s)
Fibrilación Atrial , Intervención Coronaria Percutánea , Anticoagulantes/efectos adversos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrinolíticos/efectos adversos , Humanos , Metaanálisis en Red , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Resultado del Tratamiento
16.
Catheter Cardiovasc Interv ; 97(2): E227-E236, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-32438488

RESUMEN

BACKGROUND: The PARIS risk score (PARIS-rs) and percutaneous coronary intervention complexity (PCI-c) predict clinical and procedural residual ischemic risk following PCI. Their accuracy in patients undergoing unprotected left main (ULM) or bifurcation PCI has not been assessed. METHODS: The predictive performances of the PARIS-rs (categorized as low, intermediate, and high) and PCI-c (according to guideline-endorsed criteria) were evaluated in 3,002 patients undergoing ULM/bifurcation PCI with very thin strut stents. RESULTS: After 16 (12-22) months, increasing PARIS-rs (8.8% vs. 14.1% vs. 27.4%, p < .001) and PCI-c (15.2% vs. 11%, p = .025) were associated with higher rates of major adverse cardiac events ([MACE], a composite of death, myocardial infarction [MI], and target vessel revascularization), driven by MI/death for PARIS-rs and target lesion revascularization/stent thrombosis for PCI-c (area under the curves for MACE: PARIS-rs 0.60 vs. PCI-c 0.52, p-for-difference < .001). PCI-c accuracy for MACE was higher in low-clinical-risk patients; while PARIS-rs was more accurate in low-procedural-risk patients. ≥12-month dual antiplatelet therapy (DAPT) was associated with a lower MACE rate in high PARIS-rs patients, (adjusted-hazard ratio 0.42 [95% CI: 0.22-0.83], p = .012), with no benefit in low to intermediate PARIS-rs patients. No incremental benefit with longer DAPT was observed in complex PCI. CONCLUSIONS: In the setting of ULM/bifurcation PCI, the residual ischemic risk is better predicted by a clinical risk estimator than by PCI complexity, which rather appears to reflect stent/procedure-related events. Careful procedural risk estimation is warranted in patients at low clinical risk, where PCI complexity may substantially contribute to the overall residual ischemic risk.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Humanos , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Factores de Riesgo , Stents , Resultado del Tratamiento
17.
Eur Radiol ; 31(6): 4031-4041, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33355697

RESUMEN

OBJECTIVES: Enlarged main pulmonary artery diameter (MPAD) resulted to be associated with pulmonary hypertension and mortality in a non-COVID-19 setting. The aim was to investigate and validate the association between MPAD enlargement and overall survival in COVID-19 patients. METHODS: This is a cohort study on 1469 consecutive COVID-19 patients submitted to chest CT within 72 h from admission in seven tertiary level hospitals in Northern Italy, between March 1 and April 20, 2020. Derivation cohort (n = 761) included patients from the first three participating hospitals; validation cohort (n = 633) included patients from the remaining hospitals. CT images were centrally analyzed in a core-lab blinded to clinical data. The prognostic value of MPAD on overall survival was evaluated at adjusted and multivariable Cox's regression analysis on the derivation cohort. The final multivariable model was tested on the validation cohort. RESULTS: In the derivation cohort, the median age was 69 (IQR, 58-77) years and 537 (70.6%) were males. In the validation cohort, the median age was 69 (IQR, 59-77) years with 421 (66.5%) males. Enlarged MPAD (≥ 31 mm) was a predictor of mortality at adjusted (hazard ratio, HR [95%CI]: 1.741 [1.253-2.418], p < 0.001) and multivariable regression analysis (HR [95%CI]: 1.592 [1.154-2.196], p = 0.005), together with male gender, old age, high creatinine, low well-aerated lung volume, and high pneumonia extension (c-index [95%CI] = 0.826 [0.796-0.851]). Model discrimination was confirmed on the validation cohort (c-index [95%CI] = 0.789 [0.758-0.823]), also using CT measurements from a second reader (c-index [95%CI] = 0.790 [0.753;0.825]). CONCLUSION: Enlarged MPAD (≥ 31 mm) at admitting chest CT is an independent predictor of mortality in COVID-19. KEY POINTS: • Enlargement of main pulmonary artery diameter at chest CT performed within 72 h from the admission was associated with a higher rate of in-hospital mortality in COVID-19 patients. • Enlargement of main pulmonary artery diameter (≥ 31 mm) was an independent predictor of death in COVID-19 patients at adjusted and multivariable regression analysis. • The combined evaluation of clinical findings, lung CT features, and main pulmonary artery diameter may be useful for risk stratification in COVID-19 patients.


Asunto(s)
COVID-19 , Arteria Pulmonar , Anciano , Estudios de Cohortes , Femenino , Humanos , Italia/epidemiología , Masculino , Arteria Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , SARS-CoV-2 , Tomografía Computarizada por Rayos X
18.
Nutr Metab Cardiovasc Dis ; 31(7): 2156-2164, 2021 06 30.
Artículo en Inglés | MEDLINE | ID: mdl-34059384

RESUMEN

BACKGROUND AND AIMS: Obesity-related cardiometabolic risk factors associate with COVID-19 severity and outcomes. Epicardial adipose tissue (EAT) is associated with cardiometabolic disturbances, is a source of proinflammatory cytokines and a marker of visceral adiposity. We investigated the relation between EAT characteristics and outcomes in COVID-19 patients. METHODS AND RESULTS: This post-hoc analysis of a large prospective investigation included all adult patients (≥18 years) admitted to San Raffaele University Hospital in Milan, Italy, from February 25th to April 19th, 2020 with confirmed SARS-CoV-2 infection who underwent a chest computed tomography (CT) scan for COVID-19 pneumonia and had anthropometric data available for analyses. EAT volume and attenuation (EAT-At, a marker of EAT inflammation) were measured on CT scan. Primary outcome was critical illness, defined as admission to intensive care unit (ICU), invasive ventilation or death. Cox regression and regression tree analyses were used to assess the relationship between clinical variables, EAT characteristics and critical illness. One-hundred and ninety-two patients were included (median [25th-75th percentile] age 60 years [53-70], 76% men). Co-morbidities included overweight/obesity (70%), arterial hypertension (40%), and diabetes (16%). At multivariable Cox regression analysis, EAT-At (HR 1.12 [1.04-1.21]) independently predicted critical illness, while increasing PaO2/FiO2 was protective (HR 0.996 [95% CI 0.993; 1.00]). CRP, plasma glucose on admission, EAT-At and PaO2/FiO2 identified five risk groups that significantly differed with respect to time to death or admission to ICU (log-rank p < 0.0001). CONCLUSION: Increased EAT attenuation, a marker of EAT inflammation, but not obesity or EAT volume, predicts critical COVID-19. TRIAL REGISTRATION: NCT04318366.


Asunto(s)
Adiposidad , COVID-19/diagnóstico por imagen , Grasa Intraabdominal/diagnóstico por imagen , Obesidad/diagnóstico por imagen , Radiografía Torácica , Tomografía Computarizada por Rayos X , Anciano , COVID-19/mortalidad , COVID-19/fisiopatología , COVID-19/terapia , Femenino , Mortalidad Hospitalaria , Humanos , Grasa Intraabdominal/fisiopatología , Italia , Masculino , Persona de Mediana Edad , Obesidad/mortalidad , Obesidad/fisiopatología , Pericardio , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo
19.
Artif Organs ; 45(6): 569-576, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33277695

RESUMEN

Extracorporeal membrane oxygenation (ECMO) represents a therapeutic option for cardiopulmonary support in patients with high-risk pulmonary embolism (PE); however, no definite consensus exists on ECMO use in high-risk PE. Hence, we aim to provide insights into its real-world use pooling together all available published experiences. We performed a systematic review and pooled analysis of all published studies (up to April 17, 2020) investigating ECMO support in high-risk PE. All studies including at least four patients were collectively analyzed. Study outcomes were early all-cause death (primary endpoint) and relevant in-hospital adverse events. A total of 21 studies were included in the pooled analysis (n = 635 patients). In this population (mean age 47.8 ± 17.3 years, 44.5% females), ECMO was indicated for cardiac arrest in 62.3% and immediate ECMO support was pursued in 61.9% of patients. Adjunctive reperfusion therapies were implemented in 57.0% of patients. Pooled estimate rate of early all-cause mortality was 41.1% (95% CI 27.7%-54.5%). The most common in-hospital adverse event was major bleeding, with an estimated rate of 28.6% (95%CI 21.0%-36.3%). At meta-regression analyses, no significant impact of multiple covariates on the primary endpoint was found. In this systematic review of patients who received ECMO for high-risk PE, pooled all-cause mortality was 41.1%. Principal indication for ECMO was cardiac arrest, cannulation was chiefly performed at presentation, and major bleeding was the most common complication.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Embolia Pulmonar/terapia , Enfermedad Aguda , Humanos
20.
Catheter Cardiovasc Interv ; 95(6): 1104-1108, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-31373415

RESUMEN

OBJECTIVES: To evaluate the impact of coronary sinus (CS) Reducer implantation upon left ventricular (LV) function. BACKGROUND: CS Reducer implantation is associated with symptomatic relief in patients with refractory angina. The effects of the device upon left ventricular function remains unknown. METHODS: Prior to device implantation and at 4-months, resting ventricular volumes and function were measured using cardiac magnetic resonance (CMR). Stress CMR was performed to extract quantitative indices of myocardial perfusion (myocardial perfusion reserve index-MPRI). RESULTS: Nineteen patients (18 males, 66.0 [IQR 56.0-77.0] years), underwent successful Reducer implantation. Sixteen (84%) patients improved by at least 1 CCS class. Four months after Reducer implantation, we noticed a significant improvement in LV ejection fraction (LVEF) (61 [IQR 47-71] to 66 [IQR 57-72] %; p = .009), a reduction in LV end-diastolic volume (LVEDV)/Body surface area (BSA) (65.7 [IQR 57.4-89.6] to 64.7 [IQR 53.7-74.1] mL/m2 ; p = .036) and a reduction in LV end-systolic volume (LVESV)/BSA (28.7 [IQR 18.6-38.8] to 20.0 [IQR 15.0-31.4] mL/m2 ; p = .007). Patients with reduced EF (EF < 50%, n = 6) presented a greater increase of EF at follow up compared to patients with preserved EF (11.3 [IQR 6.5-54.5] vs. 3.8 [IQR 0.6-9.1] %; p = .029). The observed decrease in LVESV/BSA was greater in patients with reduced EF (23.6 [IQR 11.6-33.8] vs. 4.2 [IQR -2.0 to 8.4] mL/m2 ; p = .005). A significant increase in transmural MPRI was observed 4 months after Reducer implantation (p < .011). CONCLUSIONS: CS Reducer improved angina symptoms and improved left ventricular function. The improvement was pronounced in the subgroup of patients with reduced ejection fraction. Myocardial perfusion improvement could represent the underlying mechanism for the observed benefits.


Asunto(s)
Angina de Pecho/terapia , Cateterismo Cardíaco/instrumentación , Circulación Coronaria , Seno Coronario/fisiopatología , Volumen Sistólico , Función Ventricular Izquierda , Anciano , Angina de Pecho/diagnóstico por imagen , Angina de Pecho/fisiopatología , Cateterismo Cardíaco/efectos adversos , Seno Coronario/diagnóstico por imagen , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA