RESUMEN
Magnetic resonance spectroscopy (MRS) thermometry offers a noninvasive, localized method for estimating temperature by leveraging the temperature-dependent chemical shift of water relative to a temperature-stable reference metabolite under suitable calibration. Consequentially, this technique has significant potential as a tool for postmortem MR examinations in forensic medicine and pathology. In these examinations, the deceased are examined at a wide range of body temperatures, and MRS thermometry may be used for the temperature adjustment of magnetic resonance imaging (MRI) protocols or for corrections in the analysis of MRI or MRS data. However, it is not yet clear to what extent postmortem changes may influence temperature estimation with MRS thermometry. In addition, N-acetylaspartate, which is commonly used as an in vivo reference metabolite, is known to decrease with increasing postmortem interval (PMI). This study shows that lactate, which is not only present in significant amounts postmortem but also has a temperature-stable chemical shift, can serve as a suitable reference metabolite for postmortem MRS thermometry. Using lactate, temperature estimation in postmortem brain tissue of severed sheep heads was accurate up to 60 h after death, with a mean absolute error of less than 0.5°C. For this purpose, published calibrations intended for in vivo measurements were used. Although postmortem decomposition resulted in severe metabolic changes, no consistent deviations were observed between measurements with an MR-compatible temperature probe and MRS thermometry with lactate as a reference metabolite. In addition, MRS thermometry was applied to 84 deceased who underwent a MR examination as part of the legal examination. MRS thermometry provided plausible results of brain temperature in comparison with rectal temperature. Even for deceased with a PMI well above 60 h, MRS thermometry still provided reliable readings. The results show a good suitability of MRS thermometry for postmortem examinations in forensic medicine.
Asunto(s)
Espectroscopía de Resonancia Magnética , Cambios Post Mortem , Termometría , Espectroscopía de Resonancia Magnética/métodos , Animales , Termometría/métodos , Ovinos , Autopsia , Humanos , Ácido Láctico/metabolismo , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Temperatura , Temperatura CorporalRESUMEN
The aims of this study are to retrospectively evaluate the diagnostic value of T1- and T2-weighted 3-T magnetic resonance imaging (MRI) for postmortem detection of myocardial infarction (MI) in terms of sensitivity and specificity and to compare the MRI appearance of the infarct area with age stages. Postmortem MRI examinations (n = 88) were retrospectively reviewed for the presence or absence of MI by two raters blinded to the autopsy results. The sensitivity and specificity were calculated using the autopsy results as the gold standard. A third rater, who was not blinded to the autopsy findings, reviewed all cases in which MI was detected at autopsy for MRI appearance (hypointensity, isointensity, hyperintensity) of the infarct area and the surrounding zone. Age stages (peracute, acute, subacute, chronic) were assigned based on the literature and compared with the age stages reported in the autopsy reports. The interrater reliability between the two raters was substantial (κ = 0.78). Sensitivity was 52.94% (both raters). Specificity was 85.19% and 92.59%. In 34 decedents, autopsy identified an MI (peracute: n = 7, acute: n = 25, chronic: n = 2). Of 25 MI classified as acute at autopsy, MRI classified peracute in four cases and subacute in nine cases. In two cases, MRI suggested peracute MI, which was not detected at autopsy. MRI could help to classify the age stage and may indicate the area for sampling for further microscopic examination. However, the low sensitivity requires further additional MRI techniques to increase the diagnostic value.
Asunto(s)
Infarto del Miocardio , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Infarto del Miocardio/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Autopsia/métodosRESUMEN
PURPOSE: To evaluate the added value of ultra-short echo time (UTE) and fast field echo resembling a CT using restricted echo-spacing (FRACTURE) MR sequences in the assessment of the osseous cervical spine using CT as reference. MATERIALS AND METHODS: Twenty-seven subjects underwent postmortem CT and MRI within 48 h. Datasets were anonymized and analyzed retrospectively by two radiologists. Morphological cervical spine alterations were rated on CT, UTE and FRACTURE images. Afterward, neural foraminal stenosis was graded on standard MR and again after viewing additional UTE/FRACTURE sequences. To evaluate interreader and intermodality reliability, intra-class correlation coefficients (ICC) and for stenosis grading Wilcoxon-matched-pairs testing with multiple comparison correction were calculated. RESULTS: Moderate interreader reliability (ICC = 0.48-0.71) was observed concerning morphological findings on all modalities. Intermodality reliability was good between modalities regarding degenerative vertebral and joint alterations (ICC = 0.69-0.91). Compared to CT neural stenosis grades were more often considered as nonsignificant on all analyzed MR sequences. Neural stenosis grading scores differed also significantly between specific bone imaging sequences, UTE and FRACTURE, to standard MR sequences. However, no significant difference was observed between UTE and FRACTURE sequences. CONCLUSION: Compared to CT as reference, UTE or FRACTURE sequence added to standard MR sequences can deliver comparable information on osseous cervical spine status. Both led to changes in clinically significant stenosis gradings when added to standard MR, mainly reducing the severity of neural foramina stenosis.
Asunto(s)
Vértebras Cervicales , Imagen por Resonancia Magnética , Humanos , Constricción Patológica , Reproducibilidad de los Resultados , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodosRESUMEN
BACKGROUND: Post-mortem imaging has been suggested as an alternative to conventional autopsy in the prenatal and postnatal periods. Noninvasive autopsies do not provide tissue for histological examination, which may limit their clinical value, especially when infection-related morbidity and mortality are suspected. METHODS: We performed a prospective, multicentre, cross-sectional study to compare the diagnostic performance of post-mortem magnetic resonance imaging with computed tomography-guided biopsy (Virtopsy®) with that of conventional autopsy in foetuses and infants. Cases referred for conventional autopsy were eligible for enrolment. After post-mortem imaging using a computed tomography scanner and a magnetic resonance imaging unit, computed tomography-guided tissue sampling was performed. Virtopsy results were compared with conventional autopsy in determining the likely final cause of death and major pathologies. The primary outcome was the proportion of cases for which the same cause of death was determined by both methods. Secondary outcomes included the proportion of false positive and false negative major pathological lesions detected by virtopsy and the proportion of computed tomography-guided biopsies that were adequate for histological examination. RESULTS: Overall, 101 cases (84 fetuses, 17 infants) were included. Virtopsy and autopsy identified the same cause of death in 91 cases (90.1%, 95% CI 82.7 to 94.5). The sensitivity and specificity of virtopsy for determining the cause of death were 96.6% (95% CI 90.6 to 98.8) and 41.7% (95% CI 19.3 to 68.0), respectively. In 32 cases (31.7%, 95% CI 23.4 to 41.3), major pathological findings remained undetected by virtopsy, and in 45 cases (44.6%, 95% CI 35.2 to 54.3), abnormalities were diagnosed by virtopsy but not confirmed by autopsy. Computed tomography-guided tissue sampling was adequate for pathological comments in 506 of 956 biopsies (52.7%) and added important diagnostic value in five of 30 cases (16.1%) with an unclear cause of death before autopsy compared with postmortem imaging alone. In 19 of 20 infective deaths (95%), biopsies revealed infection-related tissue changes. Infection was confirmed by placental examination in all fetal cases. CONCLUSIONS: Virtopsy demonstrated a high concordance with conventional autopsy for the detection of cause of death but was less accurate for the evaluation of major pathologies. Computed tomography-guided biopsy had limited additional diagnostic value. TRIAL REGISTRATION: ClinicalTrials.gov (NCT01888380).
Asunto(s)
Placenta , Tomografía Computarizada por Rayos X , Biopsia , Estudios Transversales , Femenino , Feto/diagnóstico por imagen , Humanos , Lactante , Imagen por Resonancia Magnética/métodos , Embarazo , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodosRESUMEN
BACKGROUND: Postmortem imaging has become a powerful diagnostic tool in forensics. Postmortem computed tomography (PMCT) is often used currently to complement and sometimes even replace an autopsy. PURPOSE: To compare PMCT, postmortem magnetic resonance imaging (PMMRI), and autopsy findings for gunshot wounds to the head. MATERIAL AND METHODS: Cross-sectional study. We performed a retrospective analysis of 24 cases with gunshot wounds to the head that underwent both PMCT and PMMRI between 2011 and 2018 at the Institute of Forensic Medicine, University of Zurich (Switzerland). RESULTS: Our study confirms that PMCT and, to a slightly lesser degree, PMMRI provide additional information that is valuable when combined with autopsy findings. Air embolism was solely detected in PMCT (67% vs. 0% at autopsy). A retained bullet or projectile and bone fragments were diagnosed more frequently with PMCT (42%, 67%, and 92%) than at autopsy (33%, 42%, and 46%). Soft tissue lesions were more often detected with PMMRI than with PMCT. With regard to autopsy, subdural hemorrhage and ventricular hemorrhage were slightly more frequently diagnosed with PMMRI (63% and 75% vs. 38% and 58% at autopsy). Intracerebral hemorrhage was by far most often diagnosed with PMMRI (92%) compared with both PMCT (38%) and autopsy (14%). CONCLUSION: All three modalities should ideally be considered in cases of craniocerebral gunshot wounds. However, it might be conceivable that depending on the forensic query, PMCT and PMMRI may be an adequate replacement for an autopsy.
Asunto(s)
Cabeza/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Heridas por Arma de Fuego/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Autopsia , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Suiza , Adulto JovenRESUMEN
BACKGROUND AND PURPOSE: CT is considered the modality of choice in the assessment of the skull due to the fast and accurate depiction of bone structures. Nevertheless, MRI has evolved into a possible alternative due to optimal soft tissue contrast and recent advances with the ability to visualize tissues with shortest T2 times, such as osseous structures. In this study we compare skull bone visualization and fracture detection across two MRI sequences to CT as reference standard. MATERIAL AND METHODS: Twenty subjects underwent CT and MRI with less than 72 h between examination. The MRI protocol included a 2D ultrashort echo time (UTE) and a 3D multi-echo in-phase fast-field-echo (FRACTURE) sequence. Independent raters evaluated qualitative characteristics and fracture detectability in different skull subregions (skull vault, skull base and viscerocranium). Interrater and intermodality agreement was evaluated by calculating intraclass coefficients (ICC). RESULTS: FRACTURE ICC indicated a good agreement in all subregions (ICC = 0.83 - 0.88), whereas UTE had excellent results calculated in the skull vault and viscerocranium (ICC = 0.91 - 0.94). At the skull vault, both MRI sequences received an overall good rating (UTE: 2.63 ± 0.42 FRACTURE. 2.81 ± 0.32). Fracture detection using MRI sequences for the skull vault, was highest compared to other subregions. CONCLUSIONS: Both MRI sequences may provide an alternative e.g. for surgical planning or follow up exams of the osseous neurocranium; although, at the skull base and viscerocranium bone visualization with MRI bone imaging sequences perform inferior to CT standard imaging.
Asunto(s)
Imagenología Tridimensional , Tomografía Computarizada por Rayos X , Cabeza , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Cráneo/diagnóstico por imagenRESUMEN
Coronavirus disease 19 (COVID-19) is a rapidly evolving pandemic caused by the coronavirus Sars-CoV-2. Clinically manifest central nervous system symptoms have been described in COVID-19 patients and could be the consequence of commonly associated vascular pathology, but the detailed neuropathological sequelae remain largely unknown. A total of six cases, all positive for Sars-CoV-2, showed evidence of cerebral petechial hemorrhages and microthrombi at autopsy. Two out of six patients showed an elevated risk for disseminated intravascular coagulopathy according to current criteria and were excluded from further analysis. In the remaining four patients, the hemorrhages were most prominent at the grey and white matter junction of the neocortex, but were also found in the brainstem, deep grey matter structures and cerebellum. Two patients showed vascular intramural inflammatory infiltrates, consistent with Sars-CoV-2-associated endotheliitis, which was associated by elevated levels of the Sars-CoV-2 receptor ACE2 in the brain vasculature. Distribution and morphology of patchy brain microbleeds was clearly distinct from hypertension-related hemorrhage, critical illness-associated microbleeds and cerebral amyloid angiopathy, which was ruled out by immunohistochemistry. Cerebral microhemorrhages in COVID-19 patients could be a consequence of Sars- CoV-2-induced endotheliitis and more general vasculopathic changes and may correlate with an increased risk of vascular encephalopathy.
Asunto(s)
COVID-19/complicaciones , Hemorragia Cerebral/patología , Hemorragia Cerebral/virología , Vasculitis del Sistema Nervioso Central/patología , Vasculitis del Sistema Nervioso Central/virología , Anciano , Anciano de 80 o más Años , Células Endoteliales/patología , Femenino , Humanos , Masculino , Estudios Retrospectivos , SARS-CoV-2RESUMEN
BACKGROUND: To assess changes of the craniocervical junction (CCJ), computed tomography (CT) is considered the reference standard. Recent advances in bone depiction on magnetic resonance imaging (MRI) enable high-quality visualization of osseous structures. Consequently, MRI may serve as an alternative to CT, without the use of ionizing radiation. PURPOSE: To compare two MRI sequences optimized for bone visualization to the CT reference standard in the assessment of the osseous CCJ. STUDY TYPE: Prospective. POPULATION/SUBJECTS: Twenty-seven decedents and five healthy volunteers. FIELD STRENGTH/SEQUENCE: 3T/ultrashort-echo time gradient echo (UTE) and optimized 3D-multiecho in-phase gradient echo sequences (FRACTURE). ASSESSMENT: All decedents were scanned with both MRI sequences and CT. Three observers rated degeneration to obtain a score for the upper (atlanto-dental and left/right atlanto-occipital joint) and for the lower part of the CCJ (left and right atlanto-axial joint). Two reader rated the following quantitative parameters: basion-axial-interval, atlanto-dental-interval, atlanto-occipital-interval, Powers-ratio, and signal/contrast-to-noise-ratio. As a proof of concept, five healthy volunteers were scanned with both MRI sequences. STATISTICAL TESTS: Degeneration was assessed on a Likert scale by three independent observers. Interrater and intermodality reliability were calculated using an intraclass correlation coefficient. To compare distance measurements between examination methods, a Friedman test, between-degenerative ratings, and a Kruskal-Wallis test were performed. RESULTS: Degenerative ratings of the CCJ between MRI sequences and CT showed a good interrater and intermodality agreement. MRI sequences tended to underestimate the degree of degeneration compared to CT, and this became more marked with increasing degeneration severity. There were no significant relationships between distance measurements and the degree of degeneration (PCT = 0.62, PUTE = 0.64, PFRACTURE = 0.67). The in vivo examination proved the feasibility of both MRI methods in a clinical setting. DATA CONCLUSION: Quantitative and qualitative ratings on MR images were comparable to CT images; thus, MRI may be a valid alternative to CT assessing the CCJ. LEVEL OF EVIDENCE: 1. TECHNICAL EFFICACY STAGE: 3.
Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Estudios Prospectivos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos XRESUMEN
BACKGROUND: For optimal prosthetic anchoring in omarthritis surgery, a differentiated knowledge on the mineralisation distribution of the glenoid is important. However, database on the mineralisation of diseased joints and potential relations with glenoid angles is limited. METHODS: Shoulder specimens from ten female and nine male body donors with an average age of 81.5 years were investigated. Using 3D-CT-multiplanar reconstruction, glenoid inclination and retroversion angles were measured, and osteoarthritis signs graded. Computed Tomography-Osteoabsorptiometry (CT-OAM) is an established method to determine the subchondral bone plate mineralisation, which has been demonstrated to serve as marker for the long-term loading history of joints. Based on mineralisation distribution mappings of healthy shoulder specimens, physiological and different CT-OAM patterns were compared with glenoid angles. RESULTS: Osteoarthritis grades were 0-I in 52.6% of the 3D-CT-scans, grades II-III in 34.3%, and grade IV in 13.2%, with in females twice as frequently (45%) higher grades (III, IV) than in males (22%, III). The average inclination angle was 8.4°. In glenoids with inclination ≤10°, mineralisation was predominantly centrally distributed and tended to shift more cranially when the inclination raised to > 10°. The average retroversion angle was - 5.2°. A dorsally enhanced mineralisation distribution was found in glenoids with versions from - 15.9° to + 1.7°. A predominantly centrally distributed mineralisation was accompanied by a narrower range of retroversion angles between - 10° to - 0.4°. CONCLUSIONS: This study is one of the first to combine CT-based analyses of glenoid angles and mineralisation distribution in an elderly population. The data set is limited to 19 individuals, however, indicates that superior inclination between 0° and 10°-15°, and dorsal version ranging between - 9° to - 3° may be predominantly associated with anterior and central mineralisation patterns previously classified as physiological for the shoulder joint. The current basic research findings may serve as basic data set for future studies addressing the glenoid geometry for treatment planning in omarthritis.
Asunto(s)
Cuerpo Humano , Articulación del Hombro , Anciano , Anciano de 80 o más Años , Calcificación Fisiológica , Femenino , Humanos , Masculino , Escápula , Articulación del Hombro/diagnóstico por imagen , Tomografía Computarizada por Rayos XRESUMEN
BACKGROUND: Postmortem magnetic resonance imaging (MRI) in perinatal and childhood deaths is increasingly used as a noninvasive adjunct or alternative to autopsy. Imaging protocols vary between centres and consensus guidelines do not exist. OBJECTIVE: Our aim was to develop practical, standardised recommendations for perinatal postmortem MRI. MATERIALS AND METHODS: Recommendations were based on the results of two surveys regarding local postmortem MRI practices sent electronically to all 14 members of the European Society of Paediatric Radiology (ESPR) Postmortem Imaging Task Force and 17 members of the International Society of Forensic Radiology and Imaging Task Force (25 different centres). RESULTS: Overall, 11/14 (78.6%) respondents from different institutions perform postmortem MRI. All of these centres perform postmortem MRI for perinatal and neonatal deaths, but only 6/11 (54.5%) perform imaging in older children. CONCLUSION: We propose a clinical standard for postmortem MRI sequences plus optional sequences for neuroimaging and cardiac anatomy depending on available scanning time and referral indications.
Asunto(s)
Radiología , Autopsia , Niño , Femenino , Humanos , Recién Nacido , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Embarazo , Encuestas y CuestionariosRESUMEN
The computed tomography (CT) scan of a 19-year-old man who died from an occipito-frontal gunshot wound presented an impressive radiating fracture line where the entire sagittal suture burst due to the high intracranial pressure that arose from a near-contact shot from a 9 mm bullet fired from a Glock 17 pistol. Photorealistic depictions of the radiating fracture lines along the cranial bones were created using three-dimensional reconstruction methods, such as the novel cinematic rendering technique that simulates the propagation and interaction of light when it passes through volumetric data. Since the brain had collapsed, depiction of soft tissue was insufficient on CT images. An additional magnetic resonance imaging (MRI) examination was performed, which enabled the diagnostic assessment of cerebral injuries.
Asunto(s)
Armas de Fuego , Heridas por Arma de Fuego , Adulto , Humanos , Imagenología Tridimensional , Masculino , Cráneo , Suturas , Tomografía Computarizada por Rayos X , Heridas por Arma de Fuego/diagnóstico por imagen , Adulto JovenRESUMEN
Multispectral photography offers a wide range of applications for forensic investigations. It is commonly used to detect latent evidence and to enhance the visibility of findings. Additionally, three-dimensional (3D) full-body documentation has become much easier and more affordable in recent years. However, the benefits of performing 3D imaging beyond the visible (VIS) spectrum are not well known, and the technique has not been widely used in forensic medical investigations. A multicamera setup was used to employ multispectral photogrammetry between 365 and 960 nm in postmortem investigations. The multicamera setup included four modified digital cameras, ultraviolet (UV) and near-infrared (NIR) light sources and supplemental lens filters. Full-body documentation was performed in conjunction with the use of a medical X-ray computed tomography (CT) scanner to automate the imaging procedure. Textured 3D models based on multispectral datasets from four example cases were reconstructed successfully. The level of detail and overall quality of the 3D reconstructions varied depending on the spectral range of the image data. Generally, the NIR datasets showed enhanced visibility of vein patterns and specific injuries, whereas the UV-induced datasets highlighted foreign substances on the skin. Three-dimensional multispectral full-body imaging enables the detection of latent evidence that is invisible to the naked eye and allows visualization, documentation and analysis of evidence beyond the VIS spectrum.
Asunto(s)
Imagenología Tridimensional , Fotogrametría , Autopsia , Documentación , Humanos , FotograbarRESUMEN
The temporary or permanent storage of human bodies in freezers following a homicide is a documented method for criminal disposal of human corpses. In these cases, the detection of characteristics which indicate that a thawed cadaver or body part was previously frozen provides crucial information for forensic casework. Previous histological and radiological approaches to detect characteristics of previous freezing are based on the formation of bubble-like gas patterns, which are difficult to distinguish from common postmortem gas formation in the course of decomposition. The objective of this study was to detect changes in the muscle tissue and in the bone marrow after freezing and thawing by means of in situ proton magnetic resonance spectroscopy (1 H-MRS) to provide a noninvasive approach to detect postfreezing alterations in human cadavers. In this experimental study, the hind legs of seven sheep were used as substitutes for human tissue. One hind leg underwent 1 H-MRS before and daily after storage in a deep freezer (-20°C) and complete thawing at room temperature (study group: n = 7). The opposite hind leg was kept at room temperature and was measured daily (control group: n = 7). Spectra and relaxation times were measured using single voxel measurements in the muscle tissue and in the bone marrow. 1 H-MRS revealed several changes in the muscle tissue and in the bone marrow after freezing and thawing. A strongly reduced peak area ratio (<20) between bulk methylene and olefinic and glycerol methine and a reduced T2 relaxation time for bulk methylene (<45 ms) measured in the bone marrow were found to be indicators that a sheep leg was previously frozen and thawed independent of the postmortem interval. Noninvasive in situ 1 H-MRS in the bone marrow potentially provides a new method for detecting previous freezing or extreme cooling in cadavers.
Asunto(s)
Médula Ósea/diagnóstico por imagen , Congelación , Músculos/diagnóstico por imagen , Espectroscopía de Protones por Resonancia Magnética , Animales , Cadáver , Humanos , Ovinos , Factores de Tiempo , Agua/químicaRESUMEN
In a case of a fatal traffic accident, a suspicious finding was identified in the muscular tissue of the left thigh by whole-body postmortem computed tomography. To better interpret the finding, the lower extremities were investigated by magnetic resonance imaging (MRI) and proton magnetic resonance spectroscopy (1H-MRS). MRI revealed the presence of an evenly distributed intramuscular fluid and 1H-MRS of a volume within the fluid detected concentrations of acetate and lactate. The fluid was assumed to be an extravasation of an intraosseous infusion, erroneously administered to the intermediate vastus of the left thigh during resuscitation, which was later confirmed when access to resuscitation protocols was granted. Further ex situ 1H-MRS investigations of five different infusion fluids showed the possible discrimination of the fluids and further indicated the unknown fluid to be a Ringer's acetate solution. This paper presents the case-based application of postmortem intramuscular 1H-MRS and introduces the possibility of its use to differentiate exo- and endogenic fluids for forensic interpretation. Further research for this method regarding problems in forensic pathology is needed.
Asunto(s)
Accidentes de Tránsito , Infusiones Intraóseas , Soluciones Isotónicas/administración & dosificación , Espectroscopía de Protones por Resonancia Magnética , Muslo/diagnóstico por imagen , Muslo/lesiones , Autopsia , Niño , Humanos , Absorción Intramuscular , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos XRESUMEN
INTRODUCTION: Modern forensic investigations increasingly revert to 3D imaging techniques, such as computed tomography, magnetic resonance imaging, and 3D surface imaging. Findings are therefore often based on 3D data sets; however, this information is commonly reported and communicated within 2D imagery. The use of interactive 3D PDFs is already established in the scientific community but has yet to be implemented in the field of forensic medicine. METHODS AND MATERIALS: Three example cases were chosen to serve as exemplary data for the most commonly applied imaging techniques in postmortem imaging. 3D surface models were created from postmortem magnetic resonance imaging (PMMR), postmortem computed tomography (PMCT), and 3D surface imaging data sets. RESULTS: PMMR revealed a space-occupying subdural hemorrhage that led to ipsilateral compression of the brain tissue of the right hemisphere. PMCT displayed a defect in the skull on the left side of the temporal bone. 3D surface imaging data displayed a patterned discoloration on the inside of the left forearm. DISCUSSION: Interactive 3D PDFs offer the possibility to communicate 3D information to the reader while maintaining all the benefits of a regular 2D PDF. With Adobe Acrobat, the reader can interactively navigate through 3D data sets and create sufficient depth cues to generate a realistic 3D perception of the data. CONCLUSION: The interactive 3D PDF is a useful extension of standard 2D PDFs and has the potential to communicate 3D data to the reader in a more complete, more comprehensible, and less subjective manner than 2D PDFs.
Asunto(s)
Autopsia , Presentación de Datos , Imagenología Tridimensional , Informe de Investigación , Programas Informáticos , Documentación/métodos , Medicina Legal , HumanosRESUMEN
PURPOSE: The detection and quantification of metabolites relevant for the diagnosis of fatal metabolic disorders by proton magnetic resonance spectroscopy (1H-MRS) was recently demonstrated. This prospective study aimed to compare the concentrations of beta-hydroxybutyrate (BHB), glucose (GLC), and lactate (LAC) derived from both biochemical analyses and 1H-MRS for the diagnosis of fatal metabolic disorders. METHODS: In total, 20 cases with suspected fatal metabolic disorders were included in the study. For the agreement based on thresholds, the concentrations of BHB and GLC in the vitreous humor (VH) from the right vitreous and in cerebrospinal fluid (CSF) from the right lateral ventricle were derived from 1H-MRS and biochemical analyses. The predefined thresholds for pathological elevations were 2.5 mmol/l for BHB and 10 mmol/l for GLC based on the literature. In addition, concentrations of the same metabolites in white matter (WM) tissue from the corona radiata of the right hemisphere were analyzed experimentally using both methods. To enable the biochemical analysis, a dialysate of WM tissue was produced. For all three regions, the LAC concentration was determined by both methods. RESULTS: The conclusive agreement based on thresholds was almost perfect between both methods with only one disagreement in a total of 70 comparisons due to the interference of a ferromagnetic dental brace. The differences in the concentrations between both methods showed high standard deviations. Confidence intervals of the bias not including 0 were found in CSF-GLC (- 3.1 mmol/l), WM-GLC (1.1 mmol/l), and WM-LAC (- 6.5 mmol/l). CONCLUSION: Despite a considerable total error attributable to both methods, MRS derives the same forensic conclusions as conventional biochemical analyses. An adaptation of the protocol to reduce the detected errors and more data are needed for the long-term validation of MRS for the diagnosis of fatal metabolic disorders. The production of WM dialysates cannot be recommended due to high glycolytic loss.
Asunto(s)
Ácido 3-Hidroxibutírico/análisis , Glucosa/análisis , Ácido Láctico/análisis , Enfermedades Metabólicas/diagnóstico , Enfermedades Metabólicas/mortalidad , Espectroscopía de Protones por Resonancia Magnética , Ácido 3-Hidroxibutírico/líquido cefalorraquídeo , Autopsia , Biomarcadores/análisis , Glucosa/líquido cefalorraquídeo , Humanos , Ácido Láctico/líquido cefalorraquídeo , Ventrículos Laterales/química , Estudios Prospectivos , Cuerpo Vítreo/química , Sustancia Blanca/químicaRESUMEN
BACKGROUND: The injection of muscle precursor cells (MPC) into the external urinary sphincter muscle (EUS) is a promising therapeutic option for regenerative treatment of stress urinary incontinence (SUI). The objective of the present project was to conduct a pre-clinical trial to investigate the feasibility and accuracy of ultrasound (US) guided, transurethral injections into the EUS of female cadavers. METHODS: This is a prospective, anatomical, interventional and radiological cadaveric laboratory investigation. Two urologists performed transurethral US-guided injections to deliver nano-iron particles into the EUS. The intervention was performed in three unfixed, fresh female cadavers. Each cadaver received MRI before and CT as well as MRI of the pelvis after the injections. RESULTS: The precision and accumulation of nano-iron particles in the EUS was compared using a rating scale to evaluate left versus right and anterior versus posterior distribution in axial and sagittal orientation with US, MRI and CT. The accuracy of our US-guided injections into the anterior target region yielded 4 points on the rating scale. Adequate precision and accumulation of particles in the left versus right EUS were also demonstrated (3 vs. 3.33 points, respectively). Signal intensity in MRI revealed a mean ratio of 0.33 before and after injection. CT scans showed no relevant artefacts impairing the assessment. CONCLUSION: US-guided, transurethral injection into the EUS is feasible and imaging reveals a precise accumulation in the target region. Our method provides an appropriate approach to deliver MPC in the EUS muscle for a regenerative treatment of SUI in the near future.
Asunto(s)
Inyecciones/métodos , Ultrasonografía Intervencional , Uretra/diagnóstico por imagen , Cadáver , Estudios de Factibilidad , Femenino , Humanos , Prueba de Estudio Conceptual , Reproducibilidad de los Resultados , Uretra/anatomía & histologíaRESUMEN
The use of postmortem computed tomography (CT) has been described in many articles concerning gunshot injuries. Postmortem magnetic resonance imaging (MRI) for better assessment of soft tissue injuries has also been mentioned in the literature, albeit much less often. The use of postmortem MRI for abdominal gunshot wounds has not been previously presented in the literature. The present case report describes the findings of an abdominal gunshot wound detected by postmortem CT and MRI, followed by an autopsy. The main imaging findings on CT were a hyperdense ring at the entrance wound, which indicated the muzzle imprint mark, a hyperdense region beneath the skin, which was suggestive of combustion residue, gas cavities surrounding the bullet path, which might be related to the temporary cavity, and a fracture of the 13th rib on the left. Magnetic resonance imaging provided a clear depiction of defects in the muscle tissue and peritoneal fat, as well as an injury to the left kidney and a large volume of blood in the abdominal cavity. Computed tomography combined with MRI provided a descriptive presentation of the intracorporeal trajectory noninvasively. Autopsy confirmed the radiologic findings but additionally revealed further relevant findings, which were not detected radiologically, such as a duodenal perforation. Autopsy also detected subendocardial hemorrhages and shock kidney, which were consistent with severe blood loss.The imaging findings and their interpretations are discussed in this case report, as well as the role of CT and MRI in the assessment of abdominal gunshot wounds compared with autopsy.
Asunto(s)
Traumatismos Abdominales/diagnóstico por imagen , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Heridas por Arma de Fuego/diagnóstico por imagen , Traumatismos Abdominales/patología , Músculos Abdominales/diagnóstico por imagen , Músculos Abdominales/lesiones , Músculos Abdominales/patología , Glándulas Suprarrenales/lesiones , Glándulas Suprarrenales/patología , Duodeno/lesiones , Duodeno/patología , Patologia Forense , Humanos , Perforación Intestinal/patología , Riñón/diagnóstico por imagen , Riñón/lesiones , Riñón/patología , Hígado/lesiones , Hígado/patología , Masculino , Persona de Mediana Edad , Fracturas de las Costillas/diagnóstico por imagen , Fracturas de las Costillas/patología , Bazo/lesiones , Bazo/patología , Heridas por Arma de Fuego/patologíaRESUMEN
PURPOSE: The aim of this study was to evaluate magnetic resonance imaging (MRI) findings in cases of fatal manual or ligature strangulation. Verification of strangulation by computed tomography (CT), MRI, and at autopsy as well as its detectability in each modality was assessed. METHODS: We retrospectively analyzed 6 manual and ligature strangulation cases between 2013 and 2019 who all underwent a whole-body CT, head and neck MRI, and an autopsy. Two radiologists examined head and neck imaging data and compared the data to autopsy findings. RESULTS: Magnetic resonance imaging showed a high efficiency in verifying intramuscular hemorrhages, which were confirmed in autopsy. Moreover, in one case without a visible strangulation mark, soft tissue injuries associated with strangulation were detected. Fractures, especially thyroid cartilage fractures, were successfully diagnosed by CT. CONCLUSIONS: As MRI showed a successful detection of soft tissue lesions in relation to strangulation, it can serve as an alternative method or provide additional value to an autopsy. Intramuscular hemorrhages are a common finding in manual and ligature strangulation, providing a useful sign of applied pressure on the neck. However, to evaluate fractures, an additional CT or autopsy is recommended.
Asunto(s)
Asfixia/diagnóstico por imagen , Asfixia/patología , Imagen por Resonancia Magnética , Traumatismos del Cuello/diagnóstico por imagen , Traumatismos del Cuello/patología , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Autopsia/métodos , Edema Encefálico/diagnóstico por imagen , Edema Encefálico/patología , Edema/diagnóstico por imagen , Edema/patología , Femenino , Patologia Forense , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/patología , Fracturas del Cartílago/diagnóstico por imagen , Fracturas del Cartílago/patología , Hemorragia/diagnóstico por imagen , Hemorragia/patología , Humanos , Hueso Hioides/diagnóstico por imagen , Hueso Hioides/lesiones , Hueso Hioides/patología , Cartílagos Laríngeos/diagnóstico por imagen , Cartílagos Laríngeos/lesiones , Cartílagos Laríngeos/patología , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Masculino , Músculos del Cuello/diagnóstico por imagen , Músculos del Cuello/patología , Enfisema Pulmonar/diagnóstico por imagen , Enfisema Pulmonar/patología , Estudios Retrospectivos , Fracturas Craneales/diagnóstico por imagen , Fracturas Craneales/patología , Traumatismos de los Tejidos Blandos/diagnóstico por imagen , Traumatismos de los Tejidos Blandos/patología , Cartílago Tiroides/diagnóstico por imagen , Cartílago Tiroides/lesiones , Cartílago Tiroides/patología , Imagen de Cuerpo Entero , Adulto JovenRESUMEN
Understanding natural and artificial postmortem alterations in different tissues of the human body is essential for bioarchaeology, paleogenetics, physical anthropology, forensic medicine, and many related disciplines. With this study, we tried to gain a better understanding of tissue alterations associated with the artificial mummification techniques of ancient Egypt, in particular for mummified visceral organs. We used several entire porcine organs and organ sections (liver, lung, stomach, ileum, and colon), which provided a close approximation to human organs. First, we dehydrated the specimens in artificial natron, before applying natural ointments, according to the ancient literary sources and recent publications. We periodically monitored the temperature, pH value, and weight of the specimens, in addition to radiodensity and volumetric measurements by clinical computed tomography and sampling for histological, bacteriological, and molecular analyses. After seven weeks, mummification was seen completed in all specimens. We observed a considerable loss of weight and volume, as well as similar courses in the decay of tissue architecture but varying levels of DNA degradation. Bacteriologically we did not detect any of the initially identified taxa in the samples by the end of the mummification process, nor any fungi. This feasibility study established an experimental protocol for future experiments modeling ancient Egyptian mummification of visceral organs using human specimens. Understanding desiccation and mummification processes in non-pathological tissues of specific visceral organs may help to identify and interpret disease-specific alterations in mummified tissues in ancient Egyptian canopic jars and organ packages contained in whole mummies.