Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Neurooncol ; 156(3): 579-588, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34981301

RESUMEN

BACKGROUND: Quantitative image analysis using pre-operative magnetic resonance imaging (MRI) has been able to predict survival in patients with glioblastoma (GBM). The study explored the role of postoperative radiation (RT) planning MRI-based radiomics to predict the outcomes, with features extracted from the gross tumor volume (GTV) and clinical target volume (CTV). METHODS: Patients with IDH-wildtype GBM treated with adjuvant RT having MRI as a part of RT planning process were included in the study. 546 features were extracted from each GTV and CTV. A LASSO Cox model was applied, and internal validation was performed using leave-one-out cross-validation with overall survival as endpoint. Cross-validated time-dependent area under curve (AUC) was constructed to test the efficacy of the radiomics model, and clinical features were used to generate a combined model. Analysis was done for the entire group and in individual surgical groups-gross total excision (GTR), subtotal resection (STR), and biopsy. RESULTS: 235 patients were included in the study with 57, 118, and 60 in the GTR, STR, and biopsy subgroup, respectively. Using the radiomics model, binary risk groups were feasible in the entire cohort (p < 0.01) and biopsy group (p = 0.04), but not in the other two surgical groups individually. The integrated AUC (iAUC) was 0.613 for radiomics-based classification in the biopsy subgroup, which improved to 0.632 with the inclusion of clinical features. CONCLUSION: Imaging features extracted from the GTV and CTV regions can lead to risk-stratification of GBM undergoing biopsy, while the utility in other individual subgroups needs to be further explored.


Asunto(s)
Neoplasias Encefálicas , Glioblastoma , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Glioblastoma/diagnóstico por imagen , Glioblastoma/radioterapia , Humanos , Imagen por Resonancia Magnética , Valor Predictivo de las Pruebas , Radioterapia Adyuvante , Análisis de Supervivencia
2.
J Neurooncol ; 152(3): 551-557, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33740165

RESUMEN

BACKGROUND: Stereotactic radiosurgery (SRS) is used to manage intracranial metastases in a significant fraction of patients. Local progression after SRS can often only be detected with increased volume of enhancement on serial MRI scans which may lag true progression by weeks or months. METHODS: Patients with intracranial metastases (N = 11) were scanned using hyperpolarized [Formula: see text]C MRI prior to treatment with stereotactic radiosurgery (SRS). The status of each lesion was then recorded at six months post-treatment follow-up (or at the time of death). RESULTS: The positive predictive value of [Formula: see text]C-lactate signal, measured pre-treatment, for prediction of progression of intracranial metastases at six months post-treatment with SRS was 0.8 [Formula: see text], and the AUC from an ROC analysis was 0.77 [Formula: see text]. The distribution of [Formula: see text]C-lactate z-scores was different for intracranial metastases from different primary cancer types (F = 2.46, [Formula: see text]). CONCLUSIONS: Hyperpolarized [Formula: see text]C imaging has potential as a method for improving outcomes for patients with intracranial metastases, by identifying patients at high risk of treatment failure with SRS and considering other therapeutic options such as surgery.


Asunto(s)
Neoplasias Encefálicas , Radiocirugia , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirugía , Humanos , Lactatos , Imagen por Resonancia Magnética , Estudios Retrospectivos
3.
Neuroimage ; 204: 116202, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31557546

RESUMEN

Lactate is now recognized as an important intermediate in brain metabolism, but its role is still under investigation. In this work we mapped the distribution of lactate and bicarbonate produced from intravenously injected 13C-pyruvate over the whole brain using a new imaging method, hyperpolarized 13C MRI (N = 14, ages 23 to 77). Segmenting the 13C-lactate images into brain atlas regions revealed a pattern of lactate that was preserved across individuals. Higher lactate signal was observed in cortical grey matter compared to white matter and was highest in the precuneus, cuneus and lingual gyrus. Bicarbonate signal, indicating flux of [1-13C]pyruvate into the TCA cycle, also displayed consistent spatial distribution. One-way ANOVA to test for significant differences in lactate among atlas regions gave F = 87.6 and p < 10-6. This report of a "lactate topography" in the human brain and its consistent pattern is evidence of region-specific lactate biology that is preserved across individuals.


Asunto(s)
Espectroscopía de Resonancia Magnética con Carbono-13/métodos , Corteza Cerebral/metabolismo , Sustancia Gris/metabolismo , Ácido Láctico/metabolismo , Sustancia Blanca/metabolismo , Adulto , Anciano , Atlas como Asunto , Bicarbonatos/metabolismo , Corteza Cerebral/diagnóstico por imagen , Femenino , Sustancia Gris/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Ácido Pirúvico/farmacocinética , Sustancia Blanca/diagnóstico por imagen , Adulto Joven
4.
Magn Reson Med ; 83(6): 2150-2159, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31721293

RESUMEN

PURPOSE: Asymmetric in-plane k-space sampling of EPI can reduce the minimum achievable TE in hyperpolarized 13C with spectral-spatial radio frequency pulses, thereby reducing T2* weighting and signal-losses. Partial Fourier image reconstruction exploits the approximate Hermitian symmetry of k-space data and can be applied to asymmetric data sets to synthesize unmeasured data. Here we tested whether the application of partial Fourier image reconstruction would improve spatial resolution from hyperpolarized [1- 13C ]pyruvate scans in the human brain. METHODS: Fifteen healthy control subjects were imaged using a volumetric dual-echo echo-planar imaging sequence with spectral-spatial radio frequency excitation. Images were reconstructed by zero-filling as well as with the partial Fourier reconstruction algorithm projection-on-convex-sets. Resulting images were quantitatively evaluated with a no-reference image quality assessment. RESULTS: The no-reference image sharpness metric agreed with perceived improvements in image resolution and contrast. The [1- 13C ]lactate images benefitted most, followed by the [1- 13C ]pyruvate images. The 13C -bicarbonate images were improved by the smallest degree, likely owing to relatively lower SNR. CONCLUSIONS: Partial Fourier imaging and reconstruction were shown to improve the sharpness and contrast of human HP 13C brain data and is a viable method for enhancing resolution.


Asunto(s)
Algoritmos , Imagen Eco-Planar , Encéfalo/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Ácido Pirúvico
5.
NMR Biomed ; 33(5): e4269, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32133713

RESUMEN

Hyperpolarized (HP) 13C MRI provides the means to monitor lactate metabolism noninvasively in tumours. Since 13C -lactate signal levels obtained from HP 13C imaging depend on multiple factors, such as the rate of 13C substrate delivery via the vasculature, the expression level of monocarboxylate transporters (MCTs) and lactate dehydrogenase (LDH), and the local lactate pool size, the interpretation of HP 13C metabolic images remains challenging. In this study, ex vivo tissue extract measurements (i.e., NMR isotopomer analysis, western blot analysis) derived from an MDA-MB-231 xenograft model in nude rats were used to test for correlations between the in vivo 13C data and the ex vivo measures. The lactate-to-pyruvate ratio from HP 13C MRI was strongly correlated with [1- 13C ]lactate concentration measured from the extracts using NMR (R = 0.69, p < 0.05), as well as negatively correlated with tumour wet weight (R = -  0.60, p < 0.05). In this tumour model, both MCT1 and MCT4 expressions were positively correlated with wet weight ( ρ = 0.78 and 0.93, respectively, p < 0.01). Lactate pool size and the lactate-to-pyruvate ratio were not significantly correlated.


Asunto(s)
Isótopos de Carbono/química , Imagen por Resonancia Magnética , Extractos de Tejidos/análisis , Animales , Línea Celular Tumoral , Masculino , Ratas , Ensayos Antitumor por Modelo de Xenoinjerto
6.
Magn Reson Med ; 79(2): 643-653, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28394085

RESUMEN

PURPOSE: To provide built-in off-resonance correction in time-resolved, volumetric hyperpolarized 13 C metabolic imaging by implementing a novel dual-echo 3D echo-planar imaging (EPI) sequence and reconstruction. METHODS: A spectral-spatial pulse for single-resonance excitation followed by a dual-echo 3D EPI readout was implemented to provide 64 × 8 × 6 cm3 coverage at 5 × 5 × 5 mm3 nominal resolution. Multiple sources of EPI distortions were encoded using a multi-echo 1 H EPI reference scan. Phase maps computed from the reference scans were combined with a bulk 13 C frequency offset encoded in the dual-echo [1-13 C]pyruvate images to correct geometric distortion and improve spatial registration. The proposed scheme was validated in a phantom study, and in vivo [1-13 C]pyruvate and [1-13 C]lactate rat images were acquired with intentional transmit frequency deviations to assess the dual-echo 3D EPI sequence. RESULTS: The phantom study demonstrated improved spatial registration in off-resonance corrected images. Close agreement was observed between metabolic kidney signal and the underlying anatomy in rat imaging experiments. Relative to a single-echo acquisition, the coherent addition of the two corrected echoes provided the expected increase in signal-to-noise ratio by approximately 2. CONCLUSION: A novel dual-echo 3D EPI acquisition sequence for integrated off-resonance correction in hyperpolarized 13 C imaging was developed and demonstrated. The proposed sequence offers clear advantages over flyback EPI for time-resolved metabolic mapping. Magn Reson Med 79:643-653, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Imagen Eco-Planar/métodos , Imagenología Tridimensional/métodos , Imagen Molecular/métodos , Animales , Riñón/diagnóstico por imagen , Fantasmas de Imagen , Ratas , Ratas Sprague-Dawley
7.
Circ Res ; 119(11): 1177-1182, 2016 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-27635086

RESUMEN

RATIONALE: Altered cardiac energetics is known to play an important role in the progression toward heart failure. A noninvasive method for imaging metabolic markers that could be used in longitudinal studies would be useful for understanding therapeutic approaches that target metabolism. OBJECTIVE: To demonstrate the first hyperpolarized 13C metabolic magnetic resonance imaging of the human heart. METHODS AND RESULTS: Four healthy subjects underwent conventional proton cardiac magnetic resonance imaging followed by 13C imaging and spectroscopic acquisition immediately after intravenous administration of a 0.1 mmol/kg dose of hyperpolarized [1-13C]pyruvate. All subjects tolerated the procedure well with no adverse effects reported ≤1 month post procedure. The [1-13C]pyruvate signal appeared within the chambers but not within the muscle. Imaging of the downstream metabolites showed 13C-bicarbonate signal mainly confined to the left ventricular myocardium, whereas the [1-13C]lactate signal appeared both within the chambers and in the myocardium. The mean 13C image signal:noise ratio was 115 for [1-13C]pyruvate, 56 for 13C-bicarbonate, and 53 for [1-13C]lactate. CONCLUSIONS: These results represent the first 13C images of the human heart. The appearance of 13C-bicarbonate signal after administration of hyperpolarized [1-13C]pyruvate was readily detected in this healthy cohort (n=4). This shows that assessment of pyruvate metabolism in vivo in humans is feasible using current technology. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02648009.


Asunto(s)
Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Miocardio/metabolismo , Adulto , Isótopos de Carbono , Humanos , Masculino , Persona de Mediana Edad , Ácido Pirúvico/metabolismo
8.
Magn Reson Med ; 77(2): 538-546, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-26806525

RESUMEN

PURPOSE: To enable large field-of-view, time-resolved volumetric coverage in hyperpolarized 13 C metabolic imaging by implementing a novel data acquisition and image reconstruction method based on the compressed sensing framework. METHODS: A spectral-spatial pulse for single-resonance excitation followed by a symmetric echo-planar imaging (EPI) readout was implemented for encoding a 72 × 18 cm2 field of view at 5 × 5 mm2 resolution. Random undersampling was achieved with blipped z-gradients during the ramp portion of the echo-planar imaging readout. The sequence and reconstruction were tested with phantom studies and consecutive in vivo hyperpolarized 13 C scans in rats. Retrospectively and prospectively undersampled data were compared on the basis of structural similarity in the reconstructed images and the quantification of the lactate-to-pyruvate ratio in rat kidneys. RESULTS: No artifacts or loss of resolution are evident in the compressed sensing reconstructed images acquired with the proposed sequence. Structural similarity analysis indicate that compressed sensing reconstructions can accurately recover spatial features in the metabolic images evaluated. CONCLUSION: A novel z-blip acquisition sequence for compressed sensing accelerated hyperpolarized 13 C 3D echo-planar imaging was developed and demonstrated. The close agreement in lactate-to-pyruvate ratios from both retrospectively and prospectively undersampled data from rats shows that metabolic information is preserved with acceleration factors up to 3-fold with the developed method. Magn Reson Med 77:538-546, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Espectroscopía de Resonancia Magnética con Carbono-13/métodos , Compresión de Datos/métodos , Imagen Eco-Planar/métodos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Riñón/metabolismo , Procesamiento de Señales Asistido por Computador , Algoritmos , Animales , Artefactos , Imagen Eco-Planar/instrumentación , Ácido Láctico/metabolismo , Imagen Molecular/instrumentación , Imagen Molecular/métodos , Movimiento (Física) , Fantasmas de Imagen , Ácido Pirúvico/metabolismo , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Magn Reson Med ; 75(2): 859-65, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26619820

RESUMEN

PURPOSE: Develop and test an analytic correction method to correct the signal intensity variation caused by the inhomogeneous reception profile of an eight-channel phased array for hyperpolarized (13) C imaging. THEORY AND METHODS: Fiducial markers visible in anatomical images were attached to the individual coils to provide three dimensional localization of the receive hardware with respect to the image frame of reference. The coil locations and dimensions were used to numerically model the reception profile using the Biot-Savart Law. The accuracy of the coil sensitivity estimation was validated with images derived from a homogenous (13) C phantom. Numerical coil sensitivity estimates were used to perform intensity correction of in vivo hyperpolarized (13) C cardiac images in pigs. RESULTS: In comparison to the conventional sum-of-squares reconstruction, improved signal uniformity was observed in the corrected images. CONCLUSION: The analytical intensity correction scheme was shown to improve the uniformity of multichannel image reconstruction in hyperpolarized [1-(13) C]pyruvate and (13) C-bicarbonate cardiac MRI. The method is independent of the pulse sequence used for (13) C data acquisition, simple to implement and does not require additional scan time, making it an attractive technique for multichannel hyperpolarized (13) C MRI.


Asunto(s)
Corazón/anatomía & histología , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Animales , Isótopos de Carbono , Aumento de la Imagen/métodos , Imagenología Tridimensional , Fantasmas de Imagen , Sensibilidad y Especificidad , Porcinos
11.
J Nucl Med ; 58(8): 1201-1206, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28596156

RESUMEN

This review will highlight recent advances in hyperpolarized 13C MR spectroscopic imaging, which can be used to noninvasively interrogate tumor metabolism. After providing an overview of MR and hyperpolarization, we will discuss the latest advances in data acquisition techniques. Next, we will shift our focus to hyperpolarized probe design and provide an overview of the latest hyperpolarized 13C MR spectroscopic imaging probes developed in the last several years.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias/diagnóstico por imagen , Neoplasias/metabolismo , Isótopos de Carbono , Humanos , Concentración de Iones de Hidrógeno , Procesamiento de Imagen Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA