Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Science ; 291(5505): 849-51, 2001 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-11157159

RESUMEN

Magnetic resonance imaging and spectroscopy systems use coils, either singly or as arrays, to intercept radio-frequency (RF) magnetic flux from regions of interest, often deep within the body. Here, we show that a new magnetic material offers novel possibilities for guiding RF flux to the receiver coil, permitting a clear image to be obtained where none might otherwise be detectable. The new material contains microstructure designed according to concepts taken from the field of photonic band gap materials. In the RF range, it has a magnetic permeability that can be produced to specification while exhibiting negligible direct-current magnetism. The latter property is vital to avoid perturbing the static and audio-frequency magnetic fields needed to obtain image and spectral data. The concept offers a new paradigm for the manipulation of RF flux in all nuclear magnetic resonance systems.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Magnetismo , Humanos , Ondas de Radio , Pulgar/anatomía & histología
2.
Br J Radiol ; 72(864): 1141-51, 1999 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-10703469

RESUMEN

This review describes coils for MRI that are inserted into the body through natural orifices. It covers the design and implementation of small internal receiver coils for use in the pelvis and gastrointestinal tract. Normal anatomy delineated by the high resolution obtained by using these coils and the appearances in a number of disease states for each clinical application are described.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Artefactos , Diseño de Equipo , Humanos , Sensibilidad y Especificidad
4.
Eur Radiol ; 9(3): 436-43, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10087112

RESUMEN

The use of a surface coil in MR imaging improves signal-to-noise ratio of adjacent tissues of interest. We therefore devised an endoanal receiver coil for imaging the anal sphincter. The probe is solid and re-usable: it comprises a saddle geometry receiver with integral tuning, matching and decoupling. It is placed in the anal canal and immobilised externally. Both in vitro and in vivo normal anatomy is identified. The mucosa is high signal intensity, the submucosa low signal intensity, the internal sphincter uniformly high signal intensity and the external sphincter low signal intensity on T1- and T2-weighted images. In females, the transverse perineal muscle bridges the inferior part of the external sphincter anteriorly. In perianal sepsis, collections and the site of the endoanal opening are identified. In early-onset fecal incontinence following obstetric trauma/surgery, focal sphincter defects are demonstrated; in late-onset fecal incontinence external sphincter atrophy is seen. In fecally incontinent patients with scleroderma, forward deviation of the anterior sphincter musculature with descent of rectal air and feces into the anal canal is noted. The extent of sphincter invasion is assessed in low rectal tumours. In children with congenital anorectal anomalies, abnormalities of the muscle components are defined using smaller-diameter coils. Such information is invaluable in the assessment and surgical planning of patients with a variety of anorectal pathologies.


Asunto(s)
Canal Anal/anatomía & histología , Imagen por Resonancia Magnética/instrumentación , Adulto , Enfermedades del Ano/diagnóstico , Preescolar , Diagnóstico Diferencial , Diseño de Equipo , Femenino , Humanos , Lactante , Masculino , Músculo Liso/anatomía & histología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Caracteres Sexuales
5.
Magn Reson Q ; 11(1): 45-56, 1995 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-7612423

RESUMEN

A surface coil placed within the anal canal was used to image the anal sphincter and determine normal anatomy and contrast enhancement patterns as well as appearances in disease. Sixteen normal volunteers and 24 patients were examined. Imaging was performed on a 0.5-T Picker Asset and a 1.0-T Picker HPQ Vista MRI scanner. T1-weighted and T2-weighted spin-echo, T1-weighted gradient-echo, STIR images transverse to the sphincter, and T1-weighted spin-echo images parallel to the sphincter in the coronal oblique plane were obtained. Intravenous gadopentetate dimeglumine (0.1 mmol/kg) was given to two normal subjects and 10 patients. The coil was easy to insert and well-tolerated and provided high spatial resolution. The internal sphincter had a higher signal intensity than the external sphincter on all sequences but particularly on STIR images. Brisk contrast enhancement of the internal sphincter was seen. Sphincteric abscesses and fistulous tracks were identified in three patients and confirmed at surgery. Sphincter defects were seen in three patients with obstetric trauma, and these were confirmed at surgery. Sphincter atrophy was seen in four patients with idiopathic fecal soiling. High resolution magnetic resonance imaging with a dedicated endoanal coil provides excellent visualisation of normal anatomy and pathology in and around the anal sphincter and may be of considerable value in diagnosis.


Asunto(s)
Canal Anal/anatomía & histología , Imagen por Resonancia Magnética/métodos , Enfermedades del Ano/diagnóstico , Medios de Contraste , Combinación de Medicamentos , Femenino , Gadolinio , Gadolinio DTPA , Humanos , Masculino , Meglumina , Compuestos Organometálicos , Ácido Pentético/análogos & derivados
6.
AJR Am J Roentgenol ; 169(1): 201-6, 1997 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-9207525

RESUMEN

OBJECTIVE: The purpose of this study was to obtain high-resolution MR images of the various components of the anal sphincter complex in children who have anorectal disorders. We therefore used dedicated endoanal receiver coils for MR imaging. CONCLUSION: Our pilot study suggested that MR imaging that uses a dedicated endoanal coil may have considerable diagnostic potential in children who have anorectal disorders.


Asunto(s)
Canal Anal/patología , Imagen por Resonancia Magnética/instrumentación , Adolescente , Canal Anal/anomalías , Niño , Preescolar , Medios de Contraste , Combinación de Medicamentos , Incontinencia Fecal/patología , Femenino , Gadolinio , Gadolinio DTPA , Humanos , Lactante , Imagen por Resonancia Magnética/métodos , Masculino , Meglumina , Compuestos Organometálicos , Ácido Pentético/análogos & derivados , Proyectos Piloto , Enfermedades del Recto/diagnóstico
7.
Magn Reson Med ; 40(6): 908-13, 1998 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9840836

RESUMEN

A method is described of tracking the position of a rigid device within an MR scanner and imaging with the image slice position determined by the current position of the device, such that the manipulation of the device can be achieved in a robust, interactive manner. The device can be either external or internal to the patient. The position tracking is performed by means of two or three small MR receiver coils attached to individual receiver channels. Each coil contains a small sample that acts as a fiducial (MR-visible marker point). The imaging is performed by any suitable receiver coil attached to a further receive channel. This method has a large number of applications, both in the field of MR-guided procedures and in MR imaging using endocavitary coils. In particular, two devices are described, the first being a device for MR-guided biopsies and the second being one for dynamic endorectal imaging of the anal sphincter.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Canal Anal/patología , Biopsia con Aguja/instrumentación , Biopsia con Aguja/métodos , Biopsia con Aguja/estadística & datos numéricos , Mama/patología , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Fantasmas de Imagen , Programas Informáticos
8.
J Magn Reson Imaging ; 6(5): 801-4, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-8890019

RESUMEN

We have designed a solid endorectal receiver coil for MRI of the prostate. The coil provided an improved signal-to-noise ratio up to 5 cm from its surface when compared with a standard pelvic phased array. This preliminary report describes 16 patients who were imaged using this coil, seven of whom had been examined previously with a balloon-design endorectal coil. Patient tolerance of these coils was compared. The solid coil was easy to insert and quick to set up because it did not require external tuning and matching. It avoided uncomfortable rectal distension experienced with the balloon coil as well as susceptibility artifacts from air in the balloon. In addition, it could be sterilized and reused.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Próstata/patología , Diseño de Equipo , Humanos , Masculino , Hiperplasia Prostática/diagnóstico
9.
AJR Am J Roentgenol ; 166(3): 553-9, 1996 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8623627

RESUMEN

OBJECTIVE: The purposes of this study were to assess the appearance of stage 1 neoplasia of the cervix by high-resolution MR imaging with an enveloping transvaginal receiver coil and to correlate the imaging findings with the pathologic findings. SUBJECTS AND METHODS: Fifteen patients (25-73 years old; mean, 40 years old) with clinical stage I disease were examined with a 37-mm-diameter ring-design solenoid receiver coil placed around the cervix. Axial 2.5-mm contiguous slices were obtained with a field of view of 10-15 cm on a 1.0-T HPQ Vista scanner with T1-weighted (660/20 msec [TR/TE]) and T2- weighted (2500/80 msec) spin-echo sequences and dynamic gradient-echo sequences during injection of gadopentetate dimeglumine (0.1 mmol/kg). Ten patients subsequently underwent Wertheim's hysterectomy, two underwent radiotherapy, two underwent extended cone biopsy for microinvasive disease, and one underwent a punch biopsy. For seven of 10 patients who had a hysterectomy, the widths of the tumor and the residual stroma were measured at eight radial points on the transverse images and at corresponding points on the histologic specimens at 5, 10, 15, 20, and 25 mm from the ectocervix. We then compared the widths of the tumor and the stroma on images and histologic specimens at each of these 40 points. Tumor volumes were calculated from the MR imaging and pathologic data and compared. For the other three patients, detailed MR imaging-pathology correlation was not possible because of multifocal tumor distribution (two patients) and insufficient detailed pathologic data (one patient). RESULTS: Three carcinoma types were recognized. Squamous carcinoma (nine cases) was seen as a centrally expanding intermediate-signal-intensity mass, whereas oat (small)-cell carcinoma (one case) and clear-cell carcinoma (one case) showed a multifocal distribution. For patients who had a radical hysterectomy, we noted good agreement between the widths of the tumor and the stroma determined by MR imaging and histology. Tumor volumes were determined to be 0-28.2 cm3 by MR imaging and 0-18.4 cm3 by pathology. We observed tumor extension into the immediate parametrium in four patients by MR imaging; one of these cases was not confirmed at surgery. Parametrial extension was not underestimated by MR imaging in any case. CONCLUSION: High-resolution imaging of the cervix with a transvaginal coil provides accurate assessment of the intra- and extracervical extents of tumors in clinical stage 1 cervical neoplasia.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Neoplasias del Cuello Uterino/diagnóstico , Adenocarcinoma de Células Claras/diagnóstico , Adenocarcinoma de Células Claras/patología , Adenocarcinoma de Células Claras/terapia , Adulto , Anciano , Carcinoma de Células Pequeñas/diagnóstico , Carcinoma de Células Pequeñas/patología , Carcinoma de Células Pequeñas/terapia , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/patología , Carcinoma de Células Escamosas/terapia , Femenino , Humanos , Aumento de la Imagen , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Neoplasias del Cuello Uterino/patología , Neoplasias del Cuello Uterino/terapia
10.
J Comput Assist Tomogr ; 22(3): 357-63, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9606374

RESUMEN

PURPOSE: The objective of our study was to compare MRI of fistulas-in-ano using an endoanal coil with that using a pelvic phased array coil and to assess the value of a combined approach by correlating the findings with those at surgery. METHOD: Twenty consecutive patients with clinical suspicion of perianal sepsis were studied using an endoanal coil immediately followed by a phased array coil. T1 weighted and STIR images in transverse and coronal planes were made with each coil and analysed by noting the presence and site of a collection and primary track, the position of any internal opening, and subcutaneous or supralevator extension. Operative findings were similarly recorded. RESULTS: Of 20 patients with suspected fistulas, 8 had simple fistulas, 8 had complex fistulas, and 4 had no current evidence of infection. The concordance between MR and surgery for identifying the presence and site of the collection, the primary track, and the internal opening in both simple and complex cases was superior using the endoanal coil as compared with the phased array. Both coils together reflected the findings of the endoanal coil used alone. However, for supralevator/subcutaneous extension, concordance was superior using the phased array compared with the endoanal coil, and a combined approach reflected the values of the phased array coil used alone. CONCLUSION: Endoanal MRI is highly sensitive in the delineation of fistulas-in-ano. In combination with phased array techniques, it provides valuable preoperative assessment in both simple and complex cases.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Fístula Rectal/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Canal Anal/patología , Enfermedades del Ano/diagnóstico , Enfermedades del Ano/microbiología , Infecciones Bacterianas/diagnóstico , Medios de Contraste , Enfermedad de Crohn/diagnóstico , Diseño de Equipo , Humanos , Aumento de la Imagen , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Músculo Liso/patología , Fístula Rectal/microbiología , Fístula Rectal/cirugía
11.
Magn Reson Med ; 24(1): 196-203, 1992 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-1556928

RESUMEN

Cylindrical receiver coils designed for intravaginal use were utilized to image the uterine cervix. Good quality images of the cervix, vaginal wall, and parametrium were obtained and patient tolerance of the procedure was good.


Asunto(s)
Cuello del Útero/anatomía & histología , Aumento de la Imagen/instrumentación , Imagen por Resonancia Magnética/instrumentación , Adulto , Femenino , Humanos , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Membrana Mucosa/anatomía & histología , Enfermedades del Cuello del Útero/diagnóstico , Neoplasias del Cuello Uterino/diagnóstico
12.
Magn Reson Med ; 20(2): 340-3, 1991 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-1775060

RESUMEN

A planar YBa2Cu3Ox (YBCO) coil has been used as a pick-up coil in a nuclear magnetic resonance imager. It was found that the quality factor (Q) of the YBCO coil was greater than its copper counterpart by approaching 50% even in a field of 0.15 T. The Q of the copper coil at 77 K and in a field of 0.15 T was 1200 while that of the YBCO coil under identical conditions was 1700.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Diseño de Equipo
13.
AJR Am J Roentgenol ; 163(3): 607-12, 1994 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-8079853

RESUMEN

OBJECTIVE: The purpose of this study was to characterize the normal zonal anatomy and vascularity of the cervix on in vivo and in vitro MR images obtained with a receiver coil surrounding the cervix. These appearances provide a normal data base from which to interpret subtle changes in early neoplasia. SUBJECTS AND METHODS: Thirteen women of reproductive age with clinically and cytologically normal cervices were imaged with a ring-design solenoid receiver coil that was placed intravaginally and enveloped the cervix. T1- and T2-weighted axial images were obtained. Seven uterine specimens resected for benign disease were similarly studied, and imaging appearances were correlated with histologic findings. RESULTS: In the in vivo studies, the endocervical mucosa and two stromal zones surrounding the high-signal central canal were identified. Unlike the uterine body, they could be differentiated on both T1- and T2-weighted images, on which the inner ring had a low signal and the outer ring had an intermediate signal intensity. The outer zone was highly vascularized, with inflow effects from large vessels visible on single-slice scans. On administration of gadopentetate dimeglumine, the endocervical mucosa enhanced rapidly, whereas the outer stroma showed more gradual enhancement. The inner zone enhanced slowly relative to the outer zone. The parametrium was visualized up to 6 cm from the center of the coil, and adjacent colon, fat, and blood vessels were identified. Up to four lymph nodes less than 1 cm in diameter were seen in the parametrium of three subjects. In the in vitro studies, the endocervical mucosa was of high signal intensity. In the fibromuscular cervix, an inner low-signal ring correlated with a region of tightly packed stroma (fibroblasts and smooth muscle cells; cell count, 5900 +/- 2376 nuclei/mm2) and the intermediate-signal-intensity outer zone corresponded to a region of more loosely packed stroma (cell count, 2199 +/- 558 nuclei/mm2). Retention cysts were present in two multiparous cervices. CONCLUSION: These detailed appearances and enhancement patterns of the normal cervix need to be recognized so that subtle changes in locally invasive cervical neoplasia can be identified.


Asunto(s)
Cuello del Útero/anatomía & histología , Imagen por Resonancia Magnética/instrumentación , Adulto , Medios de Contraste , Combinación de Medicamentos , Femenino , Gadolinio , Gadolinio DTPA , Humanos , Imagen por Resonancia Magnética/métodos , Meglumina , Compuestos Organometálicos , Paridad , Ácido Pentético/análogos & derivados , Valores de Referencia
14.
Dis Colon Rectum ; 39(8): 926-34, 1996 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-8756850

RESUMEN

PURPOSE: To obtain high resolution images of the anal sphincter and adjacent anorectum using an endoanal coil in patients with sepsis, trauma, and low rectal tumors and to compare imaging appearances with findings at time of surgery. PATIENTS AND METHODS: A cylindrical saddle geometry coil (diameter, 9 mm; length, 75 mm) was used to examine 30 patients (mean age, 53.6 years). Pathologies included perianal sepsis (10 patients), obstetric trauma (7 patients), and low rectal tumors (13 patients). Imaging was performed on an 0.5-T Picker Asset or 1.0-T Picker HPQ Vista (Picker International, Highland Heights, OH). T1 and T2 weighted and short inversion time inversion recovery transverse images and T1 weighted coronal images were obtained. Intravenous gadopentetate dimeglumine (0.1 mmol/kg) was given to all patients with suspected infection and neoplasms. RESULTS: Abscesses and fistulas identified using magnetic resonance imaging (MRI) in patients with perianal sepsis were confirmed at surgery in all cases; site of fistulous internal opening into the anal canal was correctly identified in 80 percent of cases. Extent of sphincter tear was correctly assessed on endoanal MRI in all patients with obstetric trauma when compared with surgical findings. Tumor invasion of anal sphincter was seen in 38.5 percent of low rectal carcinomas. CONCLUSIONS: MRI with an endoanal coil provides detailed images of the site and extent of anal fistulas, sphincter tears, and local tumors and is of considerable value in preoperative assessment.


Asunto(s)
Canal Anal/patología , Imagen por Resonancia Magnética/instrumentación , Absceso/diagnóstico , Absceso/cirugía , Canal Anal/lesiones , Canal Anal/cirugía , Parto Obstétrico/efectos adversos , Estudios de Evaluación como Asunto , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Embarazo , Proctitis/diagnóstico , Proctitis/cirugía , Estudios Prospectivos , Fístula Rectal/diagnóstico , Fístula Rectal/cirugía , Neoplasias del Recto/diagnóstico , Neoplasias del Recto/cirugía , Sensibilidad y Especificidad
15.
AJR Am J Roentgenol ; 167(6): 1465-71, 1996 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-8956578

RESUMEN

OBJECTIVE: The aim of this study was to correlate the components of the normal female anal sphincter seen on high-resolution MR images with the in vitro anatomy and to describe the change in appearances of these components in multiparous women with fecal incontinence. SUBJECTS AND METHODS: Ten asymptomatic female volunteers (32-72 years old; mean, 54 years old) and 22 women with fecal incontinence were studied. In six patients (26-68 years old; mean, 49 years old) fecal incontinence began immediately after childbirth; in the remaining 16 patients (45-77 years old; mean, 58 years old) fecal incontinence developed 15- 30 years after childbirth. In the latter group of patients, terminal motor latencies of the pudendal nerve were measured. Imaging was done on a 0.5-T Picker Asset unit and on a 1.0-T Picker HPQ unit. A saddle geometry endoanal receiver coil was used for all imaging. T1-weighted spin-echo (720-820/20 [range of TR/TE]), T2-weighted spin-echo (2500/80 [TR/TE]), fast spin-echo (4500/96 [TR/ effective TE]), and short inversion time inversion recovery (2500/80 [TR/TE]; inversion time, 107 msec) MR images were obtained in transverse, coronal oblique, and sagittal planes. Images were assessed for integrity of the sphincter components. A nonpaired separate-variance t test was used to compare thickness of individual muscle components between patients with delayed-onset fecal incontinence and asymptomatic age-matched volunteers. Degree of muscle atrophy was correlated with degree of delay in the terminal motor latency of the pudendal nerve. RESULTS: The high resolution obtained with an endoanal coil allowed differentiation of the various muscle components of the anal sphincter complex. The internal sphincter was seen as a ring of homogeneously high signal intensity with a low-signal-intensity rim that was rich in collagen and contained neurovascular bundles. The external anal sphincter, which had low signal intensity on T1- and T2-weighted images, was shown as three components: subcutaneous, superficial, and deep. In six patients who had fecal incontinence that began immediately after childbirth, endoanal MR imaging revealed the site and extent of a tear. All tears were confirmed at surgery. In the 16 patients who had fecal incontinence that began several years after childbirth, atrophy of the external sphincter was revealed in all cases in the superficial and deep components. The internal sphincter remained normal. However, we found that the degree of atrophy of individual components of the external sphincter did not correlate with the degree of delay in pudendal nerve conduction. CONCLUSION: MR imaging with an endoanal coil reveals the integrity and bulk of individual muscle components of the anal sphincter in multiparous women with fecal incontinence.


Asunto(s)
Canal Anal/patología , Incontinencia Fecal/patología , Imagen por Resonancia Magnética/instrumentación , Adulto , Anciano , Canal Anal/anatomía & histología , Canal Anal/lesiones , Canal Anal/inervación , Incontinencia Fecal/etiología , Femenino , Humanos , Técnicas In Vitro , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Conducción Nerviosa , Complicaciones del Trabajo de Parto/patología , Paridad , Embarazo , Factores de Tiempo
16.
Radiology ; 208(2): 529-35, 1998 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-9680588

RESUMEN

PURPOSE: To compare the magnetic resonance (MR) imaging appearance of the anal sphincter in patients with fecal incontinence and scleroderma with that in patients with fecal incontinence alone, scleroderma alone, or neither. MATERIALS AND METHODS: The study population comprised 14 patients with fecal incontinence and scleroderma, four with scleroderma alone, 13 with incontinence alone, and six with neither. T1- and T2-weighted spin-echo, magnetization transfer contrast-weighted, and dynamic gadolinium-enhanced images were obtained and analyzed for the integrity, thickness, and length of sphincter components. Magnetization transfer contrast ratios and T2 were calculated to assess fibrosis of the internal sphincter. The percentage enhancement above baseline was calculated at 30-second intervals for the internal and the external sphincter. RESULTS: Eleven patients with incontinence and scleroderma showed descent of rectal air and feces into the anterior anal canal, with forward deviation of the significantly (P < .05) atrophied internal sphincter, which showed a slower gadolinium-enhancement pattern compared with that in other groups. Patients with incontinence alone showed no evidence of internal sphincter deviation or altered vascularity but had a significant reduction (P < .05) in deep external sphincter bulk. CONCLUSION: In patients with fecal incontinence and scleroderma, endoanal MR imaging helps delineate the anterior sphincter deformity and shows the slower gadolinium-enhancement pattern on dynamic studies of the internal sphincter.


Asunto(s)
Canal Anal/patología , Incontinencia Fecal/diagnóstico , Imagen por Resonancia Magnética/instrumentación , Proctoscopios , Esclerodermia Sistémica/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Canal Anal/fisiopatología , Medios de Contraste , Diseño de Equipo , Incontinencia Fecal/fisiopatología , Femenino , Gadolinio DTPA , Humanos , Masculino , Manometría , Persona de Mediana Edad , Recto/patología , Recto/fisiopatología , Esclerodermia Sistémica/fisiopatología , Sensibilidad y Especificidad
17.
Clin Radiol ; 34(2): 173-88, 1983 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-6825399

RESUMEN

Fifty patients with clinical diagnoses of disease within the posterior fossa were examined with a nuclear magnetic resonance (NMR) scanner and the results were compared with X-ray computed tomography (CT). A variety of NMR pulse sequences reflecting proton density, T1, T2 and blood flow were used and imaging was performed in transverse coronal and sagittal planes. In many cases NMR provided diagnostic information unavailable from CT scans. This included recognition of lesions not seen with CT in infarction and multiple sclerosis, as well as more precise definition of mass effects, oedema and anatomical relationships in other diseases. Extrinsic and intrinsic tumours were readily distinguished, as were brain-stem and cerebellar tumours. Arnold-Chiari malformations were demonstrated with sagittal scans and cerebellar atrophy was identified. A patient treated with radiotherapy displayed more extensive changes in the surrounding brain with NMR than with CT. Evidence of occlusion or reduced flow was found in two cases with vertebro-basilar disease. Occlusion of the internal carotid artery was also demonstrated. Computed tomography was superior to NMR in demonstrating calcification and bone erosion. In four of 14 tumours studied, contrast-enhanced CT demonstrated the margin between tumour and surrounding oedema or brain better than NMR. Nuclear magnetic resonance imaging is a versatile, non-invasive technique capable of demonstrating a wide spectrum of disease within the posterior fossa.


Asunto(s)
Encefalopatías/diagnóstico , Espectroscopía de Resonancia Magnética , Adolescente , Adulto , Anciano , Encéfalo , Neoplasias Encefálicas/diagnóstico , Infarto Cerebral/diagnóstico , Niño , Preescolar , Fosa Craneal Posterior , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
18.
J Comput Assist Tomogr ; 9(2): 413-4, 1985.
Artículo en Inglés | MEDLINE | ID: mdl-3973181

RESUMEN

Spherical receiver coils suitable for magnetic resonance (MR) imaging of the brain are described. Spherical geometry permits high field uniformity with close proximity of the coil to the patient's head giving a good filling factor. Patient acceptability has been good in more than 800 examinations of the brain. Spherical receiver coils of appropriate size can provide a simple and worthwhile improvement over conventional saddle designs for low field MR imaging.


Asunto(s)
Encéfalo , Espectroscopía de Resonancia Magnética/instrumentación , Adolescente , Adulto , Niño , Preescolar , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro
19.
J Comput Assist Tomogr ; 9(4): 835-8, 1985.
Artículo en Inglés | MEDLINE | ID: mdl-4019854

RESUMEN

A method of reducing respiratory artefact when using the spin warp technique of magnetic resonance imaging is described. A respiratory signal is used to determine the order in which the rows of the data matrix are measured. The aim is to make the respiratory signal at the time of each phase encoding gradient a slowly varying function of the time integral of the gradient and hence of the row number. Data are collected during each cycle of the imaging sequence; thus the scanning time is not increased.


Asunto(s)
Espectroscopía de Resonancia Magnética/métodos , Respiración , Humanos , Movimiento , Factores de Tiempo
20.
Magn Reson Med ; 7(2): 230-5, 1988 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-3398770

RESUMEN

This communication describes the design and application of a receiver coil operating at liquid nitrogen temperature and intended as a surface coil in a whole-body imager. Its particular application is seen as the external receiver for parasitic internal or implanted detectors.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Congelación , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA